HomeMy WebLinkAboutEAGLE RIVER VALLEY RANCHETTES LT 29D (o.-3-t7 T L(
JHS^,PALity o� Q -;,.1",(-17
( 7 tell
0„,„..,____....„.A .
MUNICIPALITY OF ANCHORAGE ,, ,
On-Site Water&Wastewater Program
_.,,,>,` . S '.
PO Box 196650 4700 Elmore Road
1,104,
Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax: (907)343-7997
http://www.muni.orglonsite
Artilluof
Di I,artinunt
4NCM ON;" '
On-Site Wastewater Disposal System Permit
Permit Number: OSP171271 Effective Date: 9/28/2017
Work Type: Septic Upgrade Expiration Date: 9/28/2018
Tax Code Number: 05022405000
Site Legal Address: EAGLE RIVER VALLEY RANCHETTES LT 29D G:0054
Site Mailing Address: 19007 TWENTY GRAND RD, Eagle River
Owner: BALLESTEROS JOE E & DIANA B Lot Size in Sq Ft: 17955
Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: 3
This permit is for the construction of:
El Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well 0 Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
tat , ,Jo , ,,,k, 1
Received By: �► Date:
0/
Issued By: - rwrZ,o-CX Date: V2V-20/r
MUNICIPALITY OF ANCHORAGE
9--�77
i
Community Development Department Phone; 907- 4
Development Services Division Fa 907-34 --7997
On-Site Water& Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION 1"-:\' ., '�ti
Ci 6
Parcel I.D. 050-224-05
Property owner(s) Joe & Diana Ballesterds Day phone
Mailing address 19007 Twenty Grand Road
Site address 19007 Twenty Grand Road
Legal description (Sub'd., Block & Lot) Eagle River Valley Ranchettes, Lot 29D
Legal description (Township, Range & Section)
Lot Size 17,995 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(®all that apply)
Absorption Field ❑X Initial ❑ Single Family (SF) ❑X
(w/wo ADU)
Septic Tank ❑X Upgrade Duplex (D) ❑
Holding Tank ❑ Renewal ❑
Multiple Dwellings ❑
Privy ❑ (SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(nature of property owne or authorized agent)
Permit/Rush Fees: OSP0- p234 Waiver Fees:
Date of Payment: Qr!j � Date of Payment:
Receipt Number: 010Z1l Receipt Number:
/�
Permit No. v SPni?.-9'i Waiver No.
Permit App_:-: :._..c
Pannone Engineering Services ac
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail:steve@Danengak.com
September 27, 2017
Subject: Eagle River Valley Ranchettes, Lot 29D
Upgrade Septic System Permit Request
Design Narrative
This is a design narrative for a permit to install an upgrade septic system to be issued for this property.
The proposed system will serve an existing three (3) bedroom house. The existing drain field is in failure
and will be decommissioned. The system will utilize a replacement 1000g septic tank and conventional
drain field. This lot and the surrounding lots are served by AWWU water. There are no wells within 200'
of the proposed septic system.
1. Soils. One test hole was performed in the vicinity of this system by PES in September 2017, and
groundwater was monitored for at least seven days. Ground water was not observed to a depth of 13'
below the surface in the test hole monitor tube in September of 2017. Bedrock was not encountered
in the test hole to 13'. Based on the results of the percolation tests and overall soils appearance; an
application rate of 1.2 gallons/day/square was used for a conventional wastewater system in the area
of the test hole.
2. Soil Absorption System Design.
a. See Sheet 1 of the design package.
3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field.
The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage
ditches.
4. Topography: The existing topography on the lot generally slopes from south to north, with a
slope of approximately 10% in the area of the drain field. There are no steep slopes within 50' of this
system. The proposed drain field will maintain 50' separation all steep slopes.
5. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that
the review is complete and that there are no further comments is received from MoA On-Site
Department, the note will be removed and "Issued for Construction" drawings will be issued.
The proposed installation will not affect the future development of this or the surrounding lots.
Mailing: P.O. Box 100217, Anchorage, AK 99510-0217
Physical: 332 East Manor, Anchorage, AK 99501
Telephone: (907) 272-8218 FAX: (907) 272-8211
i
k .
/
w w w w w w ' w w w w— V\
_
I
,
--
UPGRADE DRAINFIELD (P) —
4OLF x 5.0'W x 4.0'ED x 7,0'TD
SS
10.2 10.0
EXISTING CRIB IN FAILURE i
I I
DECOMMISSION PER CODE �� mo ,
I
1 L � T 29D .
1 � TH-1
DECOMMISSION EXISTING 111I �"
SEPTIC TANK PER CODE
INSTALL 1,000g SEPTIC TANK (P)
INSTALL FOUNDATION CLEAN
OUT BEFORE TANK
AND DOUBEL CLEAN OUT AFTER 3 BR
I HOUSE
(E)
• r
w
cc
—I L . _ . .
. ____ . ____ • ___ •
DESIGN PARAMETERS
PRIMARY SEPTIC SYSTEM
NO. BEDROOM: 3 (450 gpd)
TANK SIZE: 10009
PERC RATE: 3.2 MPI
SOIL RATING: 1.2 GPD/SF
4 1, AREA RQD: 375 SF
§ .- SYS. TYPE: WIDE TRENCH 4.0'ED
W LEGEND RF: 0.50
MIN LENGTH: 37.5 LF
—w- w WATER LINE/
WELL RADIUS USE:
4OLFx5'Wx4.0' E.D., 7.0' TD
J ss NEW SEPTIC TOTAL AREA: 400 SF
NOTES: PANNONE ENG SVC, LLC _�..`\\�xDate
OF At ,t ' 9/27/2017
FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 r�P�'' A��1 + Scale
PHONE (907) 272-8218 FAX (907) 272-8211 ioj•• �4� '•,y 1"=30'
DRAWN BY: o*• .0 '` •�•• 00 P.I.D. NO
DRM
EAGLE RIVER VALLEY RANCHETTES, LOT 9D '���� ,• 050-224-05
t R. '^ no. / PERMIT NO
JOE & DIANA BALLESTEROS CE 8149
19007 TWENTY GRAND ROAD ��/.• CE .4.„0, OSP171271
PLAN EAGLE RIVER, AK 99577 0i11 % j 5c..+I Sheet
OF 3
\\X�
SOILS LOG - PERCOLATION TEST
TEST HOLE 1
SLOPE SITE PLAN
ORGANICS!
1 OR/OL ORGANIC
SILTS - w —w -w w w w w-- w-- w-
2
_E-- — — 71--- _ .- — +
4
5
6 I \_ L 29D
7TM 1/T
x I �
8 TH .
GM/ SILTY GRAVEL I I
9 SM AND SAND
10
11 ` I
12
13 1
WAS GROUND WATER SLOPE
14 ENCOUNTERED? N
15 IF YES,AT WHAT TH
16 DEPTH? ---- x
17 DEPTH TO WATER AFTER
MONITORING? -DRY-
18 DATE: 9/14/2017
WATER
19 BOH READING DATE CLOCKTIMENET TIME LEVEL NET DROP
READING
DATE PERFORMED:9!712017 1 9/07/2017 9:50 --- 5.18
2 10:00 10 MIN 9• .21 4,03
3 10:005.18
4 10:10 1• 0 MIN 8.79 3.61
5 10:10 --- 5.18
6 10:20 10 MIN 8.44 3.26
7 10:20 --- 5.18
B 10:30 1• 0 MIN 8• .34 3.16
9 10:30 --- 5.18
10 10:40 1• 0 MIN 8• .30 3.12
PEROLATION RATE 3.2(min/inch)PERC HOLE DIAMETER 6 inches
TEST RUN BETWEEN 4 FT AND 5 FT
COMMENTS:Test hole excavated by JR's SEPTIC
PERFORMED BY: Dan Moran. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE
AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
NOTES: ����\�\\ Date
PANNONE ENG SVC, LLC —` of AL <<1 Date9/2701
FOR CONSTRUCTION �- `i.•••••.fl k�
P.O. BOX 102954 ANCHORAGE, A 99510 '� S
PHONE (907) 272-8218 FAX (907) 272-8211 ic33'P ,) - •'�yf+ Scale
DRAWN BY: %* •'-49TH _t.j'` ' e NTS
ORM % • 0 P.I.D. NO
EAGLE RIVER VALLEY RANCHETTES, LOT 2�D—% � , ,. 050-224-05
/ Vim' .''` o e , PERMIT NO.
JOE & DIANA BALLESTEROS �� CE 8149 . �?5 OSP171271
19007 TWENTY GRAND ROAD c, • ,�
SOILS LOG
EAGLE RIVER, AK 99577 x',1,,,,;•..
ais=!`�-` Sheet 3
\\�,�
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF
ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF
ON—SITE WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.55.
2. SCOPE OF WORK: REMOVE AND REPLACE SOIL ABSORPTION SYSTEM AND SEPTIC TANK.
3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 13 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE
SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 13 FEET
BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY.
4, THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) HAD THE WELL LOCATION AND SEPTIC LOCATION
STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED SYSTEM
STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE WORK.
5. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED.
6. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES.
7. THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING
AND LOCATES WERE IN PLACE PRIOR TO NOTIFYING THE ENGINEER.
8. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SI
CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN.
9. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED—LINE AS—BUILT DRAWINGS TO THE
ENGINEER. THE RED—LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS, AND
TANK ELEVATIONS.
10. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF
EXCAVATION, TOP OF PIPE WITH CLEAN—OUTS AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING.
11. THE CONTRACTOR SHALL PROVIDE DATA (UPON WHICH THE RECORD DRAWING WILL BE BASED) THAT REPRESENTS
THE PROJECT AS CONSTRUCTED. THIS DATA IN CONJUNCTION WITH THE PERIODIC FIELD OBSERVATIONS BY THE
ENGINEER (OR HIS DESIGNEE) AS REQUIRED BY AMC 15.65 DOES NOT GUARANTEE THAT THERE ARE NO HIDDEN
DEFECTS BY THE CONTRACTOR.
12. THE CONTRACTOR SHALL SIGN THE FOLLOWING:
I CERTIFY THAT ALL WORK WAS PERFORMED IN ACCORDANCE WITH THE APPEND PERMIT, AND ANY AND ALL CHANGE
ORDERS, AND THAT THE AS—BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS
CONSTRUCTED.
CONTRACTOR:
BY: . TITLE:
DATE: ABBREVIATIONS
TH TEST HOLE
EA EACH
FCO FOUNDATION CLEAN OUT
T# TANK CLEAN OUT NO.
C# CLEAN OUT NO.
M# MONITOR TUBE NO.
R.I. RIGID INSULATION
DCO DOUBLE CLEAN OUT
DV DIVERTER VALVE
FS FLOW SPLITTER
(E) EXISTING
(P) PROPOSED
TYP TYPICAL
NOTES: ��� �\ Dote
PANNONE ENG SVC, LLC - of A� i��
FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 '��.•• • qS � 9i27i2017
PHONE (907) 272-8218 FAX (907) 272-8211 � +� Scale
DRAWN BY: — *: ._ �\ *� NTS
DRM 40.110
:� � P.I.D. NO
EAGLE RIVER VALLEY RANCHETTES, LOT • / 050-224-05
JOE & DIANA BALLESTEROS even '. Pannone % PERMIT NO.
19007 TWENTY GRAND ROAD fj+ Qs. CE 8149 . � OSP171271
DESIGN DETAILS EAGLE RIVER, AK 99577 �R1p�E -� Sheet
3 OF 3
BLOCK ,Zq LOT ( S ) —
ADDRESS j,OT) 1 -_
Ke-Ybox As-Built
DiDOIL
I I
AD
t
Date— Work Performed Condit' o-rt- of Keybox/Com to