Loading...
HomeMy WebLinkAboutEAGLE RIVER VALLEY RANCHETTES LT 29D (o.-3-t7 T L( JHS^,PALity o� Q -;,.1",(-17 ( 7 tell 0„,„..,____....„.A . MUNICIPALITY OF ANCHORAGE ,, , On-Site Water&Wastewater Program _.,,,>,` . S '. PO Box 196650 4700 Elmore Road 1,104, Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax: (907)343-7997 http://www.muni.orglonsite Artilluof Di I,artinunt 4NCM ON;" ' On-Site Wastewater Disposal System Permit Permit Number: OSP171271 Effective Date: 9/28/2017 Work Type: Septic Upgrade Expiration Date: 9/28/2018 Tax Code Number: 05022405000 Site Legal Address: EAGLE RIVER VALLEY RANCHETTES LT 29D G:0054 Site Mailing Address: 19007 TWENTY GRAND RD, Eagle River Owner: BALLESTEROS JOE E & DIANA B Lot Size in Sq Ft: 17955 Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: 3 This permit is for the construction of: El Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing tat , ,Jo , ,,,k, 1 Received By: �► Date: 0/ Issued By: - rwrZ,o-CX Date: V2V-20/r MUNICIPALITY OF ANCHORAGE 9--�77 i Community Development Department Phone; 907- 4 Development Services Division Fa 907-34 --7997 On-Site Water& Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION 1"-:\' ., '�ti Ci 6 Parcel I.D. 050-224-05 Property owner(s) Joe & Diana Ballesterds Day phone Mailing address 19007 Twenty Grand Road Site address 19007 Twenty Grand Road Legal description (Sub'd., Block & Lot) Eagle River Valley Ranchettes, Lot 29D Legal description (Township, Range & Section) Lot Size 17,995 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field ❑X Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank ❑X Upgrade Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (nature of property owne or authorized agent) Permit/Rush Fees: OSP0- p234 Waiver Fees: Date of Payment: Qr!j � Date of Payment: Receipt Number: 010Z1l Receipt Number: /� Permit No. v SPni?.-9'i Waiver No. Permit App_:-: :._..c Pannone Engineering Services ac Steven R. Pannone, Principal Registered Professional Engineer E-mail:steve@Danengak.com September 27, 2017 Subject: Eagle River Valley Ranchettes, Lot 29D Upgrade Septic System Permit Request Design Narrative This is a design narrative for a permit to install an upgrade septic system to be issued for this property. The proposed system will serve an existing three (3) bedroom house. The existing drain field is in failure and will be decommissioned. The system will utilize a replacement 1000g septic tank and conventional drain field. This lot and the surrounding lots are served by AWWU water. There are no wells within 200' of the proposed septic system. 1. Soils. One test hole was performed in the vicinity of this system by PES in September 2017, and groundwater was monitored for at least seven days. Ground water was not observed to a depth of 13' below the surface in the test hole monitor tube in September of 2017. Bedrock was not encountered in the test hole to 13'. Based on the results of the percolation tests and overall soils appearance; an application rate of 1.2 gallons/day/square was used for a conventional wastewater system in the area of the test hole. 2. Soil Absorption System Design. a. See Sheet 1 of the design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 4. Topography: The existing topography on the lot generally slopes from south to north, with a slope of approximately 10% in the area of the drain field. There are no steep slopes within 50' of this system. The proposed drain field will maintain 50' separation all steep slopes. 5. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On-Site Department, the note will be removed and "Issued for Construction" drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 i k . / w w w w w w ' w w w w— V\ _ I , -- UPGRADE DRAINFIELD (P) — 4OLF x 5.0'W x 4.0'ED x 7,0'TD SS 10.2 10.0 EXISTING CRIB IN FAILURE i I I DECOMMISSION PER CODE �� mo , I 1 L � T 29D . 1 � TH-1 DECOMMISSION EXISTING 111I �" SEPTIC TANK PER CODE INSTALL 1,000g SEPTIC TANK (P) INSTALL FOUNDATION CLEAN OUT BEFORE TANK AND DOUBEL CLEAN OUT AFTER 3 BR I HOUSE (E) • r w cc —I L . _ . . . ____ . ____ • ___ • DESIGN PARAMETERS PRIMARY SEPTIC SYSTEM NO. BEDROOM: 3 (450 gpd) TANK SIZE: 10009 PERC RATE: 3.2 MPI SOIL RATING: 1.2 GPD/SF 4 1, AREA RQD: 375 SF § .- SYS. TYPE: WIDE TRENCH 4.0'ED W LEGEND RF: 0.50 MIN LENGTH: 37.5 LF —w- w WATER LINE/ WELL RADIUS USE: 4OLFx5'Wx4.0' E.D., 7.0' TD J ss NEW SEPTIC TOTAL AREA: 400 SF NOTES: PANNONE ENG SVC, LLC _�..`\\�xDate OF At ,t ' 9/27/2017 FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 r�P�'' A��1 + Scale PHONE (907) 272-8218 FAX (907) 272-8211 ioj•• �4� '•,y 1"=30' DRAWN BY: o*• .0 '` •�•• 00 P.I.D. NO DRM EAGLE RIVER VALLEY RANCHETTES, LOT 9D '���� ,• 050-224-05 t R. '^ no. / PERMIT NO JOE & DIANA BALLESTEROS CE 8149 19007 TWENTY GRAND ROAD ��/.• CE .4.„0, OSP171271 PLAN EAGLE RIVER, AK 99577 0i11 % j 5c..+I Sheet OF 3 \\X� SOILS LOG - PERCOLATION TEST TEST HOLE 1 SLOPE SITE PLAN ORGANICS! 1 OR/OL ORGANIC SILTS - w —w -w w w w w-- w-- w- 2 _E-- — — 71--- _ .- — + 4 5 6 I \_ L 29D 7TM 1/T x I � 8 TH . GM/ SILTY GRAVEL I I 9 SM AND SAND 10 11 ` I 12 13 1 WAS GROUND WATER SLOPE 14 ENCOUNTERED? N 15 IF YES,AT WHAT TH 16 DEPTH? ---- x 17 DEPTH TO WATER AFTER MONITORING? -DRY- 18 DATE: 9/14/2017 WATER 19 BOH READING DATE CLOCKTIMENET TIME LEVEL NET DROP READING DATE PERFORMED:9!712017 1 9/07/2017 9:50 --- 5.18 2 10:00 10 MIN 9• .21 4,03 3 10:005.18 4 10:10 1• 0 MIN 8.79 3.61 5 10:10 --- 5.18 6 10:20 10 MIN 8.44 3.26 7 10:20 --- 5.18 B 10:30 1• 0 MIN 8• .34 3.16 9 10:30 --- 5.18 10 10:40 1• 0 MIN 8• .30 3.12 PEROLATION RATE 3.2(min/inch)PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 4 FT AND 5 FT COMMENTS:Test hole excavated by JR's SEPTIC PERFORMED BY: Dan Moran. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. NOTES: ����\�\\ Date PANNONE ENG SVC, LLC —` of AL <<1 Date9/2701 FOR CONSTRUCTION �- `i.•••••.fl k� P.O. BOX 102954 ANCHORAGE, A 99510 '� S PHONE (907) 272-8218 FAX (907) 272-8211 ic33'P ,) - •'�yf+ Scale DRAWN BY: %* •'-49TH _t.j'` ' e NTS ORM % • 0 P.I.D. NO EAGLE RIVER VALLEY RANCHETTES, LOT 2�D—% � , ,. 050-224-05 / Vim' .''` o e , PERMIT NO. JOE & DIANA BALLESTEROS �� CE 8149 . �?5 OSP171271 19007 TWENTY GRAND ROAD c, • ,� SOILS LOG EAGLE RIVER, AK 99577 x',1,,,,;•.. ais=!`�-` Sheet 3 \\�,� SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON—SITE WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.55. 2. SCOPE OF WORK: REMOVE AND REPLACE SOIL ABSORPTION SYSTEM AND SEPTIC TANK. 3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 13 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 13 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. 4, THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) HAD THE WELL LOCATION AND SEPTIC LOCATION STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE WORK. 5. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED. 6. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES. 7. THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING AND LOCATES WERE IN PLACE PRIOR TO NOTIFYING THE ENGINEER. 8. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SI CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN. 9. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED—LINE AS—BUILT DRAWINGS TO THE ENGINEER. THE RED—LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS, AND TANK ELEVATIONS. 10. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF EXCAVATION, TOP OF PIPE WITH CLEAN—OUTS AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING. 11. THE CONTRACTOR SHALL PROVIDE DATA (UPON WHICH THE RECORD DRAWING WILL BE BASED) THAT REPRESENTS THE PROJECT AS CONSTRUCTED. THIS DATA IN CONJUNCTION WITH THE PERIODIC FIELD OBSERVATIONS BY THE ENGINEER (OR HIS DESIGNEE) AS REQUIRED BY AMC 15.65 DOES NOT GUARANTEE THAT THERE ARE NO HIDDEN DEFECTS BY THE CONTRACTOR. 12. THE CONTRACTOR SHALL SIGN THE FOLLOWING: I CERTIFY THAT ALL WORK WAS PERFORMED IN ACCORDANCE WITH THE APPEND PERMIT, AND ANY AND ALL CHANGE ORDERS, AND THAT THE AS—BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS CONSTRUCTED. CONTRACTOR: BY: . TITLE: DATE: ABBREVIATIONS TH TEST HOLE EA EACH FCO FOUNDATION CLEAN OUT T# TANK CLEAN OUT NO. C# CLEAN OUT NO. M# MONITOR TUBE NO. R.I. RIGID INSULATION DCO DOUBLE CLEAN OUT DV DIVERTER VALVE FS FLOW SPLITTER (E) EXISTING (P) PROPOSED TYP TYPICAL NOTES: ��� �\ Dote PANNONE ENG SVC, LLC - of A� i�� FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 '��.•• • qS � 9i27i2017 PHONE (907) 272-8218 FAX (907) 272-8211 � +� Scale DRAWN BY: — *: ._ �\ *� NTS DRM 40.110 :� � P.I.D. NO EAGLE RIVER VALLEY RANCHETTES, LOT • / 050-224-05 JOE & DIANA BALLESTEROS even '. Pannone % PERMIT NO. 19007 TWENTY GRAND ROAD fj+ Qs. CE 8149 . � OSP171271 DESIGN DETAILS EAGLE RIVER, AK 99577 �R1p�E -� Sheet 3 OF 3 BLOCK ,Zq LOT ( S ) — ADDRESS j,OT) 1 -_ Ke-Ybox As-Built DiDOIL I I AD t Date— Work Performed Condit' o-rt- of Keybox/Com to