Expired permit (05P141473) . MOA has
confirmed that the onsite systems have
not been installed .
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
October 16, 2017
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage. AK 99519-6650
Subject: Lot 3. Riclin Subdivision
Well and Septic System Permit No. OSP141473
Dear Debbie:
We have not been contacted by the owner of Lot 3, Riclin Subdivision since the permit
was issued in 2014. An inspection yesterday indicated no activity has occurred on the
lot. We have no further involvement in the project until we are contacted by the owner.
Sincerely,
Michael E. Anderson, P.E.
Attachment
On-Site Water & Wastewater System Permit
,11, rit.
# MUNICIPALITY OF ANCHORAGE
,� Development Services Department
On-Site Water&Wastewater Program
"-..1111116,41.16'11'r
� `
4700 Elmore Road, PO Box 196650 ��
ll�Department
Anchorage,
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP141473
Tax Code Number: 05153140000
Work Type: WellSeptic Initial
Permit Effective Dates: August 25, 2015 to August 24, 2016
Design Engineer: ANDERSON ENGINEERING
Subdivision: RICLIN
Site Legal Address: RICLIN LT 3 G:1462
Owner/Address: GROSKREUTZ NOAH G
PO BOX 102221 ANCHORAGE AK 995102221
Site Mailing Address: Lot Size in Sq Ft: 52796
Total Bedrooms: 6
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By: '" C Date: —tS
Issued By: /leCe— (�" Date: 91jr5—
MUNICIPALITY OF ANCHORAGE
Community Development Department1 Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On-Site Water& Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 051-531-48
Property owner(s) Noah Groskreutz Day phone 748-0878
Mailing address P.O. Box 102221 Anchorage, AK 99510
Site address 24920 Miltherrie Court Chugiak, AK 99567
Legal description (Sub'd., Block& Lot) Riclin, Lot 3
Legal description (Township, Range& Section)
Lot Size 47,701 Sq. Ft. Number of Bedrooms Six (6)
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(®all that apply)
Absorption Field 0 Initial Single Family (SF) El
(w/wo ADU)
Septic Tank Q Upgrade ❑ Duplex (D) ❑
Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑
Privy ❑ SUBMITTAI (SF and/or D)
Private Well
Water Storage p OCT 21 2014
THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
14
(Signature of property owner or authorized agent)
Permit/Rush Fees: 5— 2L5 Waiver Fees:
Date of Payment: tolu))M (. j, Date of Payment:
Receipt Number: 03112 G Receipt Number:
Permit No. OS*l H 14'19 Waiver No.
Permit App_9-1-12.doc
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
October 21, 2014
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 3, Riclin Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 3, Riclin Subdivision intends to construct a new six-bedroom home on
the lot. We are therefore requesting a permit be issued for the construction of a new
well and septic system to accommodate the home. The attached Site Plan and backup
documentation identify the location and configuration of the proposed well and septic
system along with the alternate site. Also identified on the plans are the existing wells
and septic systems on surrounding lots. No conflicts exist between the proposed septic
system and well or septic systems and wells on adjacent lots. Drainage contours are
shown on the site plan showing the grade and direction of flow on the lot. The drainage
pattern will not be changed as a result of this project.
A test hole was placed on the lot in the area of the absorption trench and alternate site.
The logs indicate gravel (GM) with sand and silt in the zone specified for the absorption
trench. The percolation rate of the soil was determined to be 4 minutes per inch. No
groundwater was found during the placement of the test hole and none developed
during the monitoring period. An application rate of 1.2 gallons per day per square foot
was used in the design of the absorption system. We are proposing to place a new
2,000-gallon septic tank and a 54' long by 3' wide by 7' effective depth absorption
trench to treat and dispose of the effluent generated in the house. The elevation of the
distribution line in the absorption trench will be 3' below the surface and the total depth
will be 10'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the
absorption trench and 4' over the septic tank.
The ground surface on the lot in the area of the septic system slopes to the northwest.
The new trenches will be constructed parallel with the contours of the slope as much as
possible in conformance with Municipal requirements. The new septic system will be
Lot 3, Riclin Subdivision
October 21, 2014
Page Two
constructed a minimum of 100' from all wells and any surface water and 10' the
proposed and existing water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
1. The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
E
Michael E. Anderson, P.E.
Attachments
z
• ,MICHAEL E. ANDERSON• ••`��
�c a No. CE-a38t 4'�i
♦`l C-438.1 •
++4
6,.PorFS si'"
URS
JESSE' LE �OExisting
Well •
r `i 1
/
• ,
Existing
/
Septic
Area
$:'1
LOT 3, BLOCK 3 LOT 4, BLOCK 3
TONJESS ESTATES TONJESS ESTATES
,\
MILTHERRIE COURT
--- t', LOT 9, BLOCK 3
/t' / -- - - - TONJESS ESTATES Eng
/ / , -
Nell
GAF,
Septic
LOT 2, RICLIN Areo �'
VACANT ... - ' 13
LOT 10, BLOCK 3
TONJESS ESTATES
Existing
Well
LOT 6, RICLIN
VACANT
Areae
II i
4444 Yt...k i
=:6v .• 1A
�1
.' 49th i‘ •z} *0
"is VC:MICHAEL E. ANDERSON AREA M A P
✓d j, No. CE-4361
.
i*`i:ro /-/X,••;• SCALE 1 = 100'
a
RICLIN SUBDIVISION
LOT 3
47,701 S.F.
____:-57/„,
f 7-iiiii
t ;9-53'
01111 —
3' 5'E
111111 1
20.0
Driv-way
ote 411111444111111
MIA
/ y� p71, FC
_ poii
%o 54' Long
W•e 0 Si edr om \,
z 7' EHe tiv 0 pth Ho
mss,1, rpti. Tan- .
if 1
o , i t: C-7--- '.
b
o i iv,
z i
Propose.
(\
0 '/ Ns
e ,
s\
• /.
_......... AIL . ,,,
21 , 3'
i
',
:44-7 °F NOTE:1:44.7 OF,, ..... ` . No Surface Water Within 100' of
G7,:• `�_ ►► Proposed Septic System. LEGEND:
' 49th •`•
►` -
• CO Cleanout
SV — Septic Vent
, • ••Iii FCO — Foundation Cleanout
MICHAEL E. ANDERSON
►►G"....-: No. CE-438i • TH — Test Hole
R t ,5;:* .•• SITE PLAN MT Monitor Tube
►'4 4a/ESS a.4 '
SCALE 1' = 50'
LOT 3, RICLIN SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Six Bedroom Home Deep Trench System
Perc. Rate: 4 Min./Inch 2,000 Gallon Septic Tank
Application Rate: 1.2 GPD/SF 7' Drainfield Rock
4 Bedrooms * 150 GPD/Bedroom = 600 SF Absorption Area
600 SF/1.2 GPD/SF/14 SF/LF = 53.6 LF Trench Length
THEREFORE: Construct a 54' Long x 3' Wide x 7' Effective Depth Absorption Trench.
Flow Line Elevation in Trench to be 3' Below Original Ground Surface. Total Depth to be
10' Below Existing Ground. Provide 3' Cover Over Absorption Trench and 4' Cover Over
Septic Tank.
eotextile Fabric
2'6"
6" O
4" Perforated
PVC (Holes Down)
7 Drainfield Rock
5'
I I
TYPICAL DEEP TRENCH SECTION �...--��.��,
(NO SCALE) � �
NOTE Grade Area Over Trench to Drain Away. : . j �:,4
Minimum 6' Separation From Bedrock. ; 49th •
Minimum 4' Separation From Groundwater. i74"-1-•*-L F-114
Minimum 100' Separation From Private Wells in the Area. r ; MICHAEL ANDERSON
Minimum 100' Separation From Surface Water or Streams:�� No. CE-4381 :•
MUNICIPALITY OF ANCHORAGE +♦•oga tiyii,a,
DEVELOPMENT SERVICES DEPARTMENT �� +♦
404,
4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 • c),•
E *.....`
49th ♦♦
SOILS LOG - PERCOLATION TEST : ♦
,:,MICHAEL E. ANDERSON
s
LEGAL DESCRIPTION: LOT 3, RICLIN SUBDIVISION *♦♦..*'''(•
):, No CE-4381 �5�
PERFORMED FOR: NOAH GROSKREUTZ �► � {... S-Skt .�`
DATE: 10/3/2012 PROJECT No.: +�11� 5;; �s
PARCEL ID#: 051-531-43 TECHNICIAN: MEA I'i"rks,i.nal Env n< rsStani
DEPI11 TEST HOLT:
(feet)
OB/OG SLOPL SITE PLAN
1 , .
2
a e
3 — .
4
4
5 — • ':' GRAVEL W/SAND SEE SITE PLAN
AND SILT
6 —p
J . .
7 •
.: 'a
8 GM
4 4
9 ° .
WAS GROUND WATER ENCOUNTERED? NO
10 ..
. A . IF YES rr WHAT DEPTH?
DEPTH OF WATER AFTER MONITORING: NONE
1 1 . • DATE OF MONITORING: 10/15/12
1 '
GROSS TIME NET TIME DEPTH TO NET DROP
1 DATE READING (MINUTES) (MINUTES) WATER (INCHES)
. (INCHES)
14 ' .e TEST HOLE PRESOAKED PRIOR TO TESTING:
15— ".�• 10/6/1? 1 11 :14 1.63"
16 2 11:44 30 9.25" 7.62"
3 11:45 1.50"
17— 4 12:15 30 9.00" 7.50"
18 5 12:16 1.25"
19 6 12:46 30 8.75" 7.50"
20
PERCOLATION RATE: 4 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN: 4 FT. and 5 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. I. MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: