Loading...
HomeMy WebLinkAboutEAGLE VISTA BLK 1 LT 2is Ea 9 le Vista x� ���,r „ «. Municipality of Anchorage On-Site Water and Wastewater Program• (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP171' 7 311 PID Number: 050-711-02 Dwelling: ❑■ Single Family(SF) ❑ Duplex(D) ❑ Multiple(SF and/or D) Project: Ill New ❑ Upgrade Name: ABSORPTION FIELD Troy Davis Homes Inc. Address ❑ Deep Trench ■❑ Shallow Trench ❑ Bed El Mound 1689 Knik Goose Bay Rd Suite 440 Wasilla, AK ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade (907)310-2501 3 0.6 GPD/SF 14.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 10.0 Ft.4.0 Ft. Eagle Vista 1 2 Fill added above original grade Gravel length Township Range Section 3.3 Ft. 75 Ft. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES 5.0 Ft. Ft. To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist.between trenches From Tank Field Tank Line 750 Ft2 1 Ft. Well >100' >100' N/A N/A >25' TANK Septic 0 S.T.E.P. 0 Holding ❑Other Manufacturer Capacity Surface Water >100' >100' N/A N/A Anchorage Tank 1000 Gal. Material Number of compartments Lot Line >5' >10' N/A N/A Steel 2 NA Foundation >10' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Pump on level at Pump off level at High water alarm at Remarks in. in. in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank D3034Tank to D3034 Installer drainfield Northern Excavating Drainfield D3034 CO/MT D3034 Inspector J. Millette, V. Pope BENCH MARK (Assumed elevation) 100 ft Inspection 1•, 1/21/18 2nd 2/21/18 Location and description 3rd 2/22/18 4' Bottom of siding on SW corner. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL 4��.�\\\ .�' OF a�.-140#1 Conditional Approval: Date ,,;.,.....4,..r.g j* 49TH %� *9 00 •• .. Benja hiller •• !O... CE 12592 \c� Li ,ie , GJ'J '. 7/31/18 ,•' V� Approved �,zitit (�+ Date g/1 1 y ,lk PROF3E1s NA�05. 1 Inspection Report_9-1-12.doc EAGLE VISTA BLOCK 1 LOT 2 PERMIT # OSP171137 PID # 050-711-02 A B FCO 2.0 31.0 \ CO1 73.6 101.9 SV1 75.3 103.5 N SV2 81.7 109.8 2C0 84.8 113.0 CO2 87.9 116.0 CO3 101.0 127.1 \ MT1 100.5 126.5 CO4 159.2 177.6 MT2 159.5 177.7 / ' . '\. %1 ...is— 10'XJTILI T EA FOMENT \N N / / \ \ N N D / 1 \ p j %® I N Z ��O / WELL i \ 1 ` 434, 10' UTILITY EASEMENT \ N N N n \ p r z \ " FCO i N fTl w / L11 // ' J \. H N /. O N.. \ -- 1000 GAL SEPTIC — — — -- TANK TANK col Y sv1 2C0 SV2 LOT 2 CO2 CO' • / TH2 •..........., / • • 75'LONGX5'WIDEX4' / / PT3 EFFECTIVE DEPTH ABSORPTION / / / 4TERNATE SITE Co. 172 TRENCH �,,�`� ��\l` LEGEND tii CO-CLEANOUT /" :•TM *�� 2C0-DOUBLE CLEANOUT FCO-FOUNDATION CLEANOUT • .. • FS-FLOW SPLITTER VALVE `✓ '. Benja•' chiller �% MH-MANHOLE �I�a�•. CE 12592 .•�` - ' 0 50 100 MT-MONITORING TUBE +t r4•. :J30,7018 .� V`r SV-SEPTIC VENT kk��pROFESSIO�.�. � = = = FEET \AN���` 1"=50' TH-TEST HOLE EAGLE VISTA B1 L2 PERMIT # OSP171137 PID # 050-711-02 N 0 0 O > (n N - - /-85.3 - - - /81.2 ///�'r 1000 GAL 80.6— 87.7 J 80.4 SEPTIC TANK J -...'''--76.3 0_ _ 80.1 FINISH GRADE g 76.8 ORIGINAL GRADE 1l :" � ±� � +.+�. ; t ;3`• r��'{Xy. Z ; • : Y : - ". ta ' F ? r'.+ri r i g ,'st• �n5C tii • .•-",; .:I'.i1,4 . w r – ' " s, .: .;.r• �' . r : i65 . 668qct •sV`Aa;.. Y,4,-A :-ir:z1 '',''' .,:1i. k, 7w••�a.%•e...ly.' a'.. �L},:0 j('yr�ti: �aOftl,f :;:Sk ?66.8 7!` �i'2r ' rscNI` : -...,2t•w4y.'ti•iys� i�t9' r1►^"ci�• y . r , z01,,r.7w ~ t� tMY � j����•r:v.j.�:; ��•.�i ?ro.t�.a-i9 < Fts.SG Y ; '� a.y� Y"* r� } : , -' p +S . AZ. •�.� St' 4:+� H 4 : iF1. Z Y r4y .C. y.J.' 4.'•-:{ • d ,, • , Ys < w.:•y vW..—'•'17� i' i 4`YtX Y�":L1{irise r- itE*�fs•'�ht � � rnl`+'y:T. )'vF�«:..?,1..; iS' Eyr 0.5'1Y22� 144014�Wmly: :Lhfyii,A .o! .r �4r.y��. t•-�S�..titi.:! iY4y.1:GG nA. mK; ;i� r, w• 2: ti 7, ,, "r " A - it `5 4s} 'i4? y., ' � :fwis Y :54:1, g . �W - r ?of ''rb:) �:- .:alkrSi;;r3�•wrami , +•ff..TKYC: a; ;N?: .r.1:.„.•,sr. t. # X%r. 62.8 J�--:—62.8 75, 1: 56.8 N NO GROUNDWATER 12/22/17 4t I I— of • ��ll /4A �1- - 1 *:49N /' •*y BenChiller : ; � PROFILE AS-BUILT ��°eE12 j•. CE 12592 �` / +t i`�PROFESS1O'-.6- i p (NO SCALE) Wheaton Water Well, Inc. 1190 N. Wasilla-Fishhook Road Wasilla, AK 99654 (907)376-2041 Name: Troy Davis Homes Address: 1689 Knick Goose Bay Road, Suite 400 City: Wasilla State: AK Zip Code: 99654 Well Site: Eagle Vista (Eagle River) Lot/Block: 2/1 Additional: Well Depth: 154 ft. From: To: Formation: 0 54 stickup,silt,gravel,gray cobble Below Ground: 152 ft. 54 112 gray hardpacked silt,gravel,boulder Above Ground: 2 ft. 112 128 silt, brown gravel / 128 135 damp silty gravel Gal Min: 6 135 154 gravel,water,wet silty gravel Static Level: 130 ft. Casing: 154ft. of 6 in. x .25 in. steel Liner Pipe: none Screened: none Perforated: none Grouted: Bentonite WATER QUALITY TESTING Depth: 20+ft. COlfxrmn F osenr{ COU1OI Develop. Method: Air Nitrates ' N D mg& Arsenic N A u)� 111111s Use of Well: Residential Drilling Method: Rotary Misc: Commercial cap Other: Well disinfected with chlorine 50 ppm. The well was pumped 5'off the bottom with 100%draw down for 2 hours and recovered at 6 gpm. Date Drilled: 6/1/2018 Driller: Ben Mattson Development Services Department Building Safety Division Awe On-Site Water & Wastewater Program E '� •j 4700 Elmore Road P.O. Box 196650 ` Mi"1 i Mark Begich Anchorage, AK 99507 SA ETY Mayor www.muni.org/onsite (907)343-7904 Pump Installation Log Well Drilling Permit Number: SW OSP171371 Date of Issue: 12/28/2017 Parcel Identification Number:050-711-02 Legal Description Property Owner Name& Address: Eagle Vista Block 1 Lot 2 Troy Davis Homes, Inc. 1689 Goose Bay Rd.#400 Wasilla,AK 99654 Pump Installation Date: 7-19-2018 Pump Intake Depth Below Top of Well Casing: 143 feet Pump Manufacturer's Name: Goulds Pump Model: 7HS05412CL Pump Size 3/4 hp Pitless Adapter Burial Depth: 11 feet Pitless Adapter Manufacturer's Name: Martinson Pitless Adapter Installer: unknown Well Disinfected Upon Completion? Q Yes ❑ No Method of Disinfection:Sterilene Comments: Pump Installer Name: Wheaton Water Well, Inc. 1190 N.Wasilla-Fishhook Rd. Wasilla,AK 99654 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. HOUSE DETAIL SCALE: 1" = 30' N ti,b`.1. 1,9 4- `p., is 4y,OL C,�o,pS o -------___,.. S(Prr 5.0'x8.0' ---. s• �'L0 BALCONY si,,F 15.0'x21.0' ��183 \ BALCONY R�4 \ ss N 1\ 13. • \ NNNN • \ N ef F \\ N PiSJ, 1• 9� WELL N ?g1 \ D o 46.o f . . , N 0 l � ti \ N Z , �9i�G,s q w , F I. N 73 / 10' UTILITY EASEMENT_IfN N n° ' rn 0 \ / N NNN rr*1 \ 7D / N I \ oE / /N\� 45) \ / \\N / NNN SEPTIC PIPES Lot 2 0, / r. \ 2.80 Acres N \-10' UTILITY EASEMENT / M 125.0' / 11(a / / co Lot 3 �°v. oa', / / 1�a 5EASEM' UTILITY / �� 0-ot '000 — — — S 89'56'45"W 260.00' — — — — —\ SO°, \\\ /// \\\ - - — — — - - .--- Lot 1 \\\ \\\ \\\ PLOT PLAN _ AS BUILT X SCALE 1" = 50' GRID SE 805 Project No. 17-403/B5 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates , inc . (907) 522-6476 Phone oopp� (907) 522-4625 Fax oc�o F A°��p Professional Land Surveyors kenOlangsurvey.com jonathanOlangsurvey.com Q��' .•'qs�0 I hereby certify that I have surveyed the following described property: '-') 49TH /\ 7 Q Lot 2, Block 1, EAGLE VISTA SUBDIVISION (Plat No. 74-204) �r • * AO Anchorage Recording District, Alaska, and that the Improvements situated thereon are ' within the property lines and do not encroach onto the property adjacent thereto, that O i/ no improvements on the property lying adjacent thereto encroach on the surveyedvO KENNETH Nti o Q premises and that there are no roadways, transmission lines or other visible easements on•said property except as Indicated hereon. 2 4'it • �O 040.-b• 520 .•� — 2,.•' Seo Dated this the 2`�� Day of 4v Z�\a5 at Anchorage, Alaska ,o,Qo tit, _#_=1, AQ �SSIONPJ- __ It is the responsibility of the owner to determine the existence of any easements, °�ODOo�• covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963 t-•Z 1 ' G-c601C .„(.1°""TT MUNICIPALITY OF ANCHORAGE ' On-Site Water&Wastewater Program • co ' 2/21/I g PO Box 196650 4700 Elmore Road /' Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 r; '30(-A + http://www.muni.org/onsite ToP lh.partment NCHoRAo On-Site Water & Wastewater System Permit Permit Number: OSP171371 Effective Date: 12/28/2017 Work Type: WellSeptic Initial Expiration Date: 12/28/2018 Tax Code Number: 05071102000 Site Legal Address: EAGLE VISTA BLK 1 LT 2 G:0805 Site Mailing Address: 3387 TALON CIR, Eagle River Owner: TROY DAVIS HOMES INC Lot Size in Sq Ft: 121861 Design Engineer: FORGE ENGINEERING Total Bedrooms: 3 This permit is for the construction of: Ef Disposal Field 0 Septic Tank 0 Holding Tank 0 Privy IO Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: 1 /'/4//1I Aatill'l 10C,0 Date: /+ Issued By: g,6660_,..41 Date: 2 28 / MUNICIPALITY OF ANCHORAGE (---.,7--, 4 a / ►► Community Development Department `'fir, ry o e: 907-343-7904 Development Services Division _-'' kit l, 2017 Fax: 907-343-7997 On-Site Water & Wastewater Program JD 'L 1 ti ON-SITE SEWER/WELL PERMIT'° ' 'LICATI `` Parcel I.D. 050-711-02 Property owner(s) Troy Davis Homes, Inc. Day phone 310-2501 Mailing address 1689 Goose Bay Road #400 Wasilla, AK 99654 Site address 3387 Talon Circle Chugiak, AK 99657 Legal description (Sub'd., Block & Lot) EAGLE VISTA, BLOCK 1, LOT 2 Legal description (Township, Range & Section) Lot Size 121,861 Sq. Ft. Number of Bedrooms Three (3)) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (0 all that apply) Absorption Field X Initial ❑X Single Family (SF) ❑X (w/wo ADU) Septic Tank IXI Upgrade I IDuplex (D) Holding Tank I 1 Renewal n Multiple Dwellings ❑ Privy I I (SF and/or D) Private Well x Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: • .�^ 'ir • . . '. - • - Distance: f-- I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. ---:.___-- _.— (Si4- ature of proplerty owner or authorized agent) Permit/Rush Fees: nq Waiver Fees: o,2�15 ' Date of Payment: i Ji5/fl' Date of Payment: rJl d,{ " Receipt Number: Q 1a41-1D Receipt t Number: - 6' 'l[li 1 n Permit No. Onpri-13--1 Waiver No. Permit App_:-:• :_..c: 1„,, ) ' GE ENGINEERING PO BOX 240773 ANCHORAGE,AK 99524 522-7773 677-7766(FAX) December 26,2017 Municipality of Anchorage Development Services Dept-On-Site Water& Wastewater Program 4700 Elmore Rd Anchorage,AK 99507 Subject: Eagle Vista Sub,Block 1, Lot 2 Septic system design and permit application Dear On-Site Services Engineer: The owner of the above lot intends to build a 3-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site.No conflicts exist between this proposed system and any wells,whether on this lot or adjacent lots. This is a large lot with more than 120,000 square feet of surface area. The well radius is contained entirely on the lot. Drainage arrows and contours are shown on the site plan showing the grade and direction of flow. The drainage pattern in general will not be changed by the construction. The test holes placed on the lot indicated different soil conditions depending on location. To the north, we found poorly graded sand with silty gravel. On the south side of the lot, we found hard clay with sand in the upper 10',with silty sand below that.No groundwater or bedrock was found down to 20'. The percolation rate in the area we are placing the trench was determined to be between 5-20 minutes per inch in the deeper sandy soils. The trench will need to be below that upper section of clay. An application rate of 0.6 gpd/sf was used in the design of the absorption system.We are proposing to place a new 1,000-gallon septic tank with a wide absorption trench 5' wide x 75' long x 4' effective depth.The elevation of the distribution line will be 10'below the surface for a total depth of 14'. Soil will be mounded .5' above the trench. A minimum of 3' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot slopes to the southwest at grades in excess of 25%,but it is over 50' from the area where we are placing the trench. The new trench will be constructed parallel to the slope as much as possible. It will be a minimum of 100' from all wells and surface water,and more than 5' away from the septic tank. The alternate site is located more than 10' away. If the system is constructed as designed, it will have no adverse impact: • On the wells in the area or those to be constructed in the future. • On existing septic systems in the area or those to be constructed in the future. • On reserve space on any lots located in the area. • On drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Benjamin Schiller, P.E. Attachments *• 1— '49 TM •i it, //TBejanSthiIIe;n r 1 .'.*• CE 12592 c`�% pis PROFESSION'+ EAGLE VISTA BLOCK 1 LOT 2 - 7 /1,1---- _. .,,.(,_ ._-_--_-- .__--:.,_:. / s;4.88.1 \` • . I/ ., TH1 • • . • 1 C -1 4 PROPOSED WELL 1 1 N_,_— 10' UTILI EASEMENT 1 N �'9O \ ' XDRIVEWAY SLOPE: N / <<\ I \ e \ APPROXIMATELY 7.3% \ O N Nv N LI 3-BDRM v N •1054.503 i _ 10' UTILITY EASEMENT \ H Z o 1000 GAL SEPTIC 7 y00 77,0 I— 6°�° s TANK 0 0 O 11 2� N sv 1 pg0 0 �O z 2C0 �q C7 I = 75'LONG X 5'WIDE X 4' O.O 7J 0 EFFECTIVE DEPTH ABSORPTION O o TRENCH o0 Ill tiP (1,11 CLEANOUT @ 100'FROM TANK P 000 LOT 2 .o co .. co 0 / • o � %TH 0 9.55% •__ O ALD'ERNATV• / . TO •QO SITE .. °' sT ........: EAGLE VISTA SUBDIVISION BLOCK 1 , LOT DESIGN FACTORS: SYSTEM REQUIREMENTS: 450 GPD PEAK FLOW 5' WIDE TRENCH SYSTEM PERK RATE: 20 MIN/IN 1000-GAL SEPTIC TANK APPLICATION RATE: 0.6 GPD/SF 450 GPD /0.6 GPD/SF/5' WIDE / .5 RED. FACTOR = 75 LF TRENCH LENGTH THEREFORE: CONSTRUCT AN ABSORPTION TRENCH 75' LONG x 5'WIDE x 4' EFFECTIVE DEPTH. FLOW LINE ELEVATION IN TRENCH TO BE 10' BELOW ORIGINAL GROUND SURFACE. TOTAL DEPTH TO BE 14' BELOW EXISTING GROUND. PROVIDE 3' COVER OVER TRENCH AND 4' COVER OVER SEPTIC TANK, OR INSULATION WITH 2' COVER. r 6 II �L111T I 11=-lll 11=1 I EL=1 I lEill=ifiElliEjil=111E1 I I1 I I-1 I EI I I-I I EI 11- 1-111=—ll1=11 — I 11 X111=11�I II I =11 t= EBE,1 I —LI 1=1LI=1 I 1-1 —1 II 11=LI 1=1 I I I J I I-1 Ell1-111-1 -I III-11 E I 1==1 11=1 I ILI= 1—III= -LII-II 1.21- 11 I=II 111-11 E11=11 l 1-III-III=T= LII=- 1 I k11 EI 11-I I 111=1 11- -11 LI 1=1 -111=1 I E1 g 5' I I En------11H I EI 11-111- 1=1 I I I-111-I 11=111=I IIEIf1=TEIETE 1=111-111-I-111-111-1 I IE1Tf=1 I EIf=1T T- 1-111-111=11 EI 11=11 T TEIIETlt1 1 EII L 1-111=111=111-1 I =1 I I TTI I I-T-TrE1 11- 1 111 111=111=1 11T=I1 TEiT--_TET f 1-111=111=111-1 I 1-1 -I 11=TTI-1 I f=-I I I- 1 STI 1-111=111=11 I-I I 1=T 6" . . ._. . . ;l. r.%. . r .•.:!:;!.,•.,!,•;!,•.,•.,!;!►�" 4" PERFORATED PVC (HOLES DOWN) •%!=!%!%!%!'.••=.r-.='�r.•%•�.•%• DRAINFIELD ROCK �rrirrr• r • • r� • • %!=O-!=!%! !=V:/=!=!%!!%! - 4' TO GROUNDWATER . r . -{ 6' TO BEDROCK OR IMPERMEABLE LAYER 5 TYPICAL 5' WIDE TRENCH SECTION oFgslll (NO SCALE) j�• 'F. 10 NOTES: • ••• GRADE AREA OVER TRENCH TO DRAIN AWAY r, .. MIN 6' SEPARATION FROM BEDROCK /r • Ben. min Schiller •:: MIN 4' SEPARATION FROM GROUNDWATER O,P``�JJ•,• of 12592,.•.•• MIN 100' SEPARATION FROM NEARBY WELLS l�k"�F�PROFESS..oeP`... MIN 100' SEPARATION FROM SURFACE WATER OR STREAMS `�\\\����` MUNICIPALITY OF ANCHORAGE _�.��1‘\�\�\, DEVELOPMENT SERVICES DEPARTMENT i�P •of :•9,1ll1 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 %*•49 �•N •777 r0// SOILS LOG AND PERCOLATION TEST / .. j / B Jamin Schiller lr F'••. CE 12592 ••`Z% LEGAL DESCRIPTION: EAGLE VISTA BI L2 - 3387 TALON CIR ,,ll;\PROFSS7.••• PERFORMED FOR: TROY DAVIS \\"` DATE: 10/06/17 PROJECT No.: PARCEL ID#: 050-71 I-02 TECHNICIAN: J. M I LLE T T E Professional Engineers Stamp: DEPTH TEST HOLE 1 (feet) I. OB SLOPE SITE PLAN 2 ':!,..'::.,•::::'::';!...:: :,} 4 ;7: 5 .f��'`';;;-' SEE SITE PLAN c . 6 ..:::. ,'.':';••. .:•,:r•: POORLY GRADED SAND �' � W/ SILT AND GRAVEL 7 ::;.•7•• ::•4-::"-..: (SP-SM) 8 • •:.. '.'.' =•.i . ?.:';-'4!..' :10 WAS GROUND WATER ENCOUNTERED? NO 1.::i%' `1; .: IF YES @ WHAT DEPTH? '-•= •• DEPTH OF WATER AFTER MONITORING: NONE 11 °; "i'i::' DATE OF MONITORING: 10/20/17 12 !‘: ':'?:;i:.:',.1 , '.: DEPTH To 13 DATE READING GROISIvuTES)E NET TIME (MINUTES) WATER NET ETCDROP (INCHES) 14 10/06 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 I 3:50 0 2 3:53 3:10 6" 6" 16 17 9 4:06 0 18 10 4:09 3:12 6" 6" 19 II 4:10 0 20 12 4:13 3:12 6" 6" PERCOLATION RATE:0.53 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 3 FT. and 4 FT. COMMENTS: PERK TEST WAS PERFORMED 6 TIMES.INTERMEDIATE RESULTS ARE NOT SHOWN BUT WERE EQUIVALENT. NORTHERN GEOTECHNICAL ENGINEERING,INC./ TERRA FIRMA TESTING 9t - PROJECT Laboratory Testing Geotechnical Engineering Instrumentation Construction Monitoring Services Thermal Analysis CLIENT: Forge Engineering %GRAVEL 39.3 USCS SP-SM PROJECT NAME: Talon Circle %SAND 50.6 USACOE FC N/A PROJECT NO.: 4879-17 %SILT/CLAY 10.1 %PASS.0.02 mm N/A SAMPLE LOC.: %MOIST.CONTENT 5.8 %PASS.0.002 mm N/A NUMBER/DEPTH: Si UNIFORMITY COEFFICIENT(Cu) UNKNOWN DESCRIPTION: Poorly-graded sand w/silt and gravel COEFFICIENT OF GRADATION(Cu) UNKNOWN DATE RECEIVED: 11/6/2017 ASTM D1557(uncorrected) N/A TESTED BY: JA ASTM D4718(corrected) N/A REVIEWED BY: RJPC OPTIMUM MOIST.CONTENT.(corrected) N/A PARTICLE SIZE ANALYSIS ASTM D422/C136 SIEVE ANALYSIS RESULT US.SIEVE oxm INCHES I US,SIEVE NUMBERS I rtYf RCMTF.R 100 i ; 'a 6 no am iii 10 alto apo SIEVE SIEVE TOTAL% SPECIFICATION 90 . SIZE(mm) SIZE(U.S.) PASSING (%PASSING) 80 ♦ 152.40 6" 76.20 3" F 70 . - 38.10 1.5" 100 cicn 60 19.00 3/4" 99 50 • . . 12.70 1/2" 88 • 9.50 3/8" 79 m 40 . - - 4.75 #4 61 --- !-------- 2.00 #10 45 30 0.85 #20 32 20 .. * 0.43 #40 24 —4--. ---4 0.25 #60 19 10 4 0.15 #100 15 0 0.075 #200 10.1 100 10 1 0.1 0.01 0.001 GRAIN SIZE(mm)SAND I HYDROMETER RESULT I GRAVEL IELAPSED0 DIAMETER TOTAL% !COBBLES CI SILT or CLAY TIME (mm) PASSING Coarse Fine Coarse Medium ha. 0.5 1 MOISTURE-DENSITY RELATIONSHIP ASTM D1557 2 4 145 _ — - 8 15 140 30 60 I 3 135i 250 • 1440 F E-' 130 - 1 HYDRAULIC COND. A I (ASTM D2434) NIA A 125 -- DEGRADATION N/A 120 .- - "-- (ATM T-313) --- N/A PLASTICITY INDEX NIA 115 -`-�--.--` ASTM 4318 0 2 4 6 8 10 12 14 16 MOISTURE CONTENT(%) The testing services reported herein have been performed to recognized industry standards,unless otherwise noted. No other warranty is made. Should engineering interpretation or opinion be required,NGL'-TFT will provide upon written request. 11301 Olive Lane • Anchorage,Alaska 99515 • Phone:907-344-5934 • fax:907-344-5993 • www.nge-t.com MUNICIPALITY OF ANCHORAGE �����N\ DEVELOPMENT SERVICES DEPARTMENT i�Q 9k-, 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 ...fib/ . .TM �� *fir/ SOILS LOG AND PERCOLATION TEST / ...,�' • ra F •. Benjay� Schiller 7#IV'•. C.y 2592 .*.(``% LEGAL DESCRIPTION: EAGLE VISTA BI L2 - 3387 TALON C I R isrF9�op �. ,P��=� PERFORMED FOR: TROY DAV IS k�\\�"`� . DATE: 12/14/17 PROJECT No.: PARCEL ID#: 050-711-02 TECHNICIAN: J. M I LLE T T E Professional Engineers Stamp: DEPTH TEST HOLE 2 (feet) 1 I' OB SLOPE SITE PLAN 2 NEEM IMO 3 —gallnIali 5 ";'��?� SEE SITE PLAN gagen 6 : <::`:`<:: HARD CLAY W/ GRAVEL A IldfiR 7 —IOWISM NEREE EINS9 WEE 2 '`i:'%•`."'•`' WAS GROUND WATER ENCOUNTERED? NO 1 O ;::$:'.:.! { IF YES L WHAT DEPTH? - itf:N -:p�.l • <,-'eil:+ DEPTH OF WATER AFTER MONITORING: NONE 11—�e4:".:::,'i ; DATE OF MONITORING: 12/22/17 IC- 12 :+7ri :L;Y: ;s:10i:ii.t DEPTH TO f = ' }x SANDY SILTY GRAVEL DATE READING GROSS TIME NET TIME WATER NET DROP 13 :t{ �:;;;.t; (MINUTES) (MINUTES) (INCHES) (INCHES) 14— �'�:iTi:"t•7 10/06 TEST HOLE PRESOAKED PRIOR TO TESTING: ''''': ;3`, I 3:00 0 ? 15 g'°t} ; .'n..4y..t t; P� t. %~;,>, 2 3:30 30:00 1.50" 1.50" 16 4Yr •'•' att - ;,: 3 3:31 0 17 ?:C14 iagiS, ;. ; 4 4:01 30:00 1.50" 1.50" ;"` ., ''xs 4:02 0 1941....nj 6 4:32 30:00 1.50" 1.50" 20 `r.>k' ' '° PERCOLATION RATE:20.0 (MIN/INCH) PERC.HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 10 FT. and 11 FT. COMMENTS: �NX��\\\ MUNICIPALITY OF ANCHORAGE �����lli DEVELOPMENT SERVICES DEPARTMENT %kP..•' ` 9,+ 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 �c SOILS LOG AND PERCOLATION TEST ...•. is 6 . Benj in Schiller : LEGAL DESCRIPTION: EAGLE VISTA BI L2 - 3387 TALON OR rf,ilrF9F0 '22292P\���r� PERFORMED FOR: TROY DAV IS t�\�N"``�4 DATE: 12/14/17 PROJECT No.: PARCEL ID#: 050 711-02 TECHNICIAN: J. MILLETTE Professional Engineers Scamp: DEPTH PERK TEST 3 (feet) 1 SLOPE SITE PLAN EggiEiRifi2 INEE NEME3 IMMES IENE4 IMBEI 5 sasom SEE SITE PLAN EMPERE 6 HARD CLAY W/ GRAVEL ; 7 Mems NOMME8 INEMB NER9 ">:""; `�k`.: i i3 i." WAS GROUND WATER ENCOUNTERED? NO 10 t'�.•':',Z:;:1 .i# IF YES(i WHAT DEPTH? - '' L'.%<i + DEPTH OF WATER AFTER MONITORING: NONE 11 '4l4:Gs:;i!yt' SANDY SILTY GRAVEL DATE OF MONITORING: 12/22/17 12 DEPTH TO DATE READING GROSS TIME NET TIME WATER NET DROP 13 (MINUTES) (MINUTES) (INCHES) (INCHES) 14 10/06 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 I 3:35 0 2 4:05 30:00 4.00" 4.00" 16 3 4:06 0 17 4 4:36 30:00 3.875" 3.875" 18 5 4:37 0 19 6 5:07 30:00 3.875" 3.875" 20 PERCOLATION RATE: 7.7 (MIN/INCH) PERC.HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 10 FT. and I I FT. COMMENTS: 89 1077 • "D MASK Pot Municipality of Anchor g On-Site Water and Wastewater Progra JUS 3 0 2018 - (907)343-7904 C s a F C T Y ti tyb 4 Certificate of On-Site Systems Appr of 6 8 I, Parcel I.D. 050-711-02 'V oV 1 Expiration Date: o( 0 I O 1. GENERAL INFORMATION Complete legal description Eagle Vista B1 L2 Location (site address) 3387 Talon Cir. Current Property owner(s) Troy Davis Homes Day phone (907) 357-9394 Mailing address 1689 Knik Goose Bay Rd. #400 Wasilla, AK 99654 Real Estate Agent Day phone 2. TYPE OF DWELLING: • Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: 1 kaffl1 �� Date: -,37/ / //(c/ COSA to be released to the engineer,unless' otherwise requested by the engineer. 1irt COSA Fee $ (ae)-1-Lir = III ( Waiver Fee $ Date of Payment 1 - 31-1 S Date of Payment Receipt Number 0416 61 h Receipt Number COSA# OSCA S 1311 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Forge Engineering Phone (907) 522-7773 Address PO Box 240773, Anchorage, AK 99524 Engineer's Printed Name Benjamin Schiller, PE Date 7/30/18 •ofq�tll j*. 49TH /\ •qtr/ 6. DSD SIGNATURE % System #1 Approved for 8 bedrooms // �. Benjani Schiller .. System#2 Approved for bedrooms F��s• C7/30/18 E 12592 �/ Y pp �ikl9' R.....0NA4 Disapproved h\���"�� Conditional approval for bedrooms, with the following stipulations: -0. OF Aivc ON-SITE 0• -Z WATER AND : WASTEWATER o: (N,› PROGRAM `go, ��h/T ncr_,.\ . By: e2M,a'(/ Original Certificate Date: � � d 1 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet_c '. c If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: Eagle Vista B1 L2 Parcel ID: 050-711-02 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) Y Date completed 6/01/18 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 154 ft. Cased to 154 ft. Casing height (above ground) 24 in. FROM WELL LOG AT INSPECTION Date of test 6/01/18 New Static water level 130 ft. ft. Well production 6 g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform Neg colonies/100 mL Nitrate ND mg/L Arsenic NDug/L Date of sample: 7/19/18 Collected by: Wheaton Water Wells B. SEPTIC/HOLDING TANK DATA Tank Type/Material Steel/SepticDate installed 1/21/18 Tank size 1000gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout(Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping Pumper New Construction C. ABSORPTION FIELD DATA Date installed 2/22/18 Soil rating (g.p.d./ft2 or ft2/bdrm) 0.6 System type 5-Wide Length 75 ft. Width 5.0 ft. Gravel below pipe 4.0. ft. Total depth 17.3 ft. Eff. absorption area 750 ft2 Monitoring tube Y Depression over field N Date of adequacy test New Results (Pass/Fail) For bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment(past 12 mo.) (Y/N &type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100' On adjacent lots >100' Absorption field on lot 100' On adjacent lots 100' Public sewer main >75' Public sewer manhole/cleanout >100' Sewer/septic service line >25' Holding tank >75' Animal containment areas >50' Manure/animal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO: Building foundation 1 0' Property line �5' Absorption field >5' >10'Water main Water service line >10 Surface water >100 Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line 1 Building foundation >10 Water main �10 ' 10' Water Service line � Surface water_ >100 Driveway, parking/vehicle storage >10' Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS G. ENGINEER'S CERTIFICATION ���—���\ of ACq‘lkl I certify that I have determined through field inspections and i7. tQ 06 review of Municipal records that the above systems are in .01, 0) conformance with MOA COSA guidelines in effect on this date. 7*'49 TM 1\ *9 Engineer's Printed Name Benjamin Schiller, PE it 7/31/18 % ....r7. . . . ' . . . . . .. . Date . Benja chiller .� ri �F••, CE12592 ••`� TO, e 7/31/18 •.• ^ 11%PROFESSION' \\\���~ COSA brown sheet 10-10-12.doc