Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RICLIN LT 1
Onsite File Riclin Lot 1 #051 - 531 - 38 Municipality of Anchorage On-Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP171366 PID Number: 051-531-38 Dwelling: ❑� Single Family (SF) ❑ Duplex (D) ❑ Multiple(SF and/or D) Project: ❑� New ❑ Upgrade Name: ABSORPTION FIELD Troy Davis Homes, Inc. Address ❑ Deep Trench ❑■ Shallow Trench ❑ Bed ❑ Mound 1689 Goose Bay Road #400 Wasilla, AK 99654 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 310-2501 3 1.2 GPD/SF 9.8 / 10.5 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 5.8 / 6.5 Ft.4.0 Ft. Riclin 1 Fill added above original grade Gravel length Township Range Section -0.9 /-0.1 Ft. 2 @ 20 Ft. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES 5.0 Ft. Ft. To Septic Absorption Lift Station Holding I1 Sewer Total absorption area Number of trenches Dist.between trenches From Tank Field Tank Line 400 Ft2 2 Ft. Well >100' >100' N/A N/A >25' TANK E Septic 0 S.T.E.P. 0 Holding ❑Other Manufacturer Capacity Surface Water >100' >100' N/A N/A Anchorage Tank 1000 Gal. Material Number of compartments Lot Line >10' >10' N/A N/A Steel 2 NA Foundation ' >10' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted I Gal. Pump on level at Pump off level at High water alarm at Remarks No insulation needed. Trenches dug into the slope, with final grade lower than original. in.; in. in. Trenches still have positive drainage away. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank D1785 Tank to D3034 Installer drainfield Sanders & Sanders Drainfield D3034 CO/MT D3034 Inspector J. Millette BENCH MARK (Assumed elevation) 100 ft Inspection 1s' 8/15/18 2nd 8/15/18 Location and description dates: 3r° a"' Bottom of siding COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Conditional Approval: Date diakk �kQ.•.• 4,--..19##J j*: 49TH /\ * , ....../ / Benja chiller 7(' • CE 12592 �� #f FC�bT•. 1121/19 chiller ... Approved k...�. 1 - Datee2- Z219 'lli`\ROFES`` 4" Inspection Report_9-1-12.doc RICLIN LOT 1 PERMIT # OSP171366 PID # 051-531-38 o 5 > 0 - (100.0 - — — _ I__. i 95.4 v V'l 94.9 1000 GAL 94.7 SEPTIC TANK I .''''.-90.6 TRENCH #1 d'(V co OF- 99.5 ORIGINAL GRADE o 99.4 FINISH GRADE - • Jy = ., --7,-, ti ' hi .-; ,� ' i ,__, ,'.•�•4`.•,tf.. t• .c:.., 97 ; f ��;� I yfrs ,P,'%:is `t .,. :t .y� ` v#s : t.):j',.A;:=r" ,tx,i. )t �93.7I3. r;p: RICLIN SUBDIVISIONLOT 1 PERMIT # OSP171366 PID # 051-531-38 1 EXISTINGV r WELL � � -`� �I ‘E2 /17 AT � / ,- i LOT w / - r L°3 40' UT :1TY & PRIVATE /"7- ACCESS -'2 <---N ,-----_v,� \ ACCESS EASEMENTj,, /� / ._ / r 33' SECTION LINE \-'N / / j �� t , EASEMENT • ,• • /I . � ( 100'WELL 1 r \.,, { RADIUS 1 . _1/ _,.,_, ' ...-9 2-20'LONG X 5'WIDE X 4',- _,7`"-__} , --� �,'-N� - EFFECTIVE DEPTH7 - - / ABSORPTION TRENCHES .�--. .. --- --c., 2-"' 'J - .--,7// ' •• EXISTING r../,. • _ / �+o IF?/"<' ,.' • SE TIC ARE/ /� r C•04 i / i2/ CO CO2 '• i ALTERNATE SITE: CATEGORY / �M-1 '. 3 BDRHON1E 1 i -/ ,,' III NITRATE REDUCING j ! ., , 501' •FS CO= i N ,'. 1 / , TH44 0 / SYSTEM W/10'LONG X 5''WIDE / •' � � oo f'�, ��--� ' �-' • X 4'EFFECTIVE DEPT SV2 �o ABSORPTION TRkNj �-!� / • ht•i ) — f I' 1 ii 1/ ..,--"2,..- NEW 1,000,LcALLON-�" • / - i 1 i 4 \ SEPTI NK / ��" 1; .1:::',,/i./// i i / i//1 T • r�. ,TH , r H -%' J J A B ^ i FCO 28.1 4,9 f ../ l / SV1 33.1 . 12.0 j • ( -../ / f j / 1 // SV2 36.9 17.6 ' i / / /,-' / / ._(--- 200 38.0 20.8 I rj • / / / ,--• FS 32.8 24.9 ; 7{1/-„7/--'7 001 41.8 34.8 i ! A / ./�.. MTI 24.9 23.5 ( /' / „// //i CO2 22.2 24:7 -- -t— — 0O3 43.5 " ' 47.7 I LANDSCAPING' T j/— //'-/// �' LOT 5 MT4 23.6 38.6 EASEMENT ��;• ;,�// f PoCL�1 I, NO CONFLIICTS WITj9 LS I , I NO CONFLICTS WITH WELLS OR SEPTIC SYSTk1r i I OR SEPTIC SYSTEM. ������\\t LEGEND ~'� 4cS',l) CO-CLEANOUT iCO.. ' .:Vtf- �f SCALE 2C0-DOUBLE CLEANOUT 1*• 49 TH •*`/° 50 100 FCO FOUNDATION CLEANOUT ' FEET FS FLOW SPLITTER VALVE / . Benja in Sailer • MH-MANHOLE rh-r.• CE 12592 •.��i� 1"=50' MT-MONITORING TUBE `re...'•• • .ai221018 •. �� . SV-SEPTIC VENT ,11\\�\x"���~ TH-TEST HOLE Wheaton Water Wed, Inc. 1190 N. Wasilla-Fishhook Road Wasilla, AK 99654 (907)376-2041 Name: Troy Davis Homes Address: 1689 S Knik Goose Bay Rd. #400 City: Wasilla State: AK Zip Code: 99654 Well Site: Riclin Lot/Block: Lot 1 Additional: Well Depth: 109 ft. From: To: Formation: 0 18 stickup,silt,gravel,cobble Below Ground: 107 ft. 18 26 gravel,silt Above Ground: 2 ft. 26 44 sand,silt Gal/Min: 10 44 91 wet sticky silt 91 99 silt,gravel Static Level: 91 ft. 99 109 gravel,water Casing: 109ft. of 6 in. x.25 in. steel Liner Pipe: • none Screened: none Perforated: none Grouted: bentonite Depth: 20ft.+ Develop. Method: Air Use of Well: Residential Drilling Method: Rotary Misc: none Other: Commercial Cap —WATER QUALITY TESTING I Coliform e y COI/100mL I Nitrates mgL I Arsenic The well was pumped 5'off the bottom with 100%draw down for 2 hours and recovered at 10 gpm. Date Drilled: 7/18/2018 Driller: Ben Mattson Development Services Department • Building Safety Division • And On-Site Water & Wastewater Program 4700 Elmore Road x • • oZ P.O. Box 196650 �w I.* '- SA ETY Mark Begich Anchorage, AK 99507 Mayor www.muni.org/onsite (907)343-7904 Pump Installation Log Well Drilling Permit Number: SW OSP171366 Date of Issue: 12/27/2017 Parcel Identification Number:051-531-38 Legal Description Property Owner Name&Address: RICLIN LOT 1 TROY DAVIS HOMES 1689 KNIK GOOSE BAY RD#400 WASILLA,AK 99654 Pump Installation Date: 12/20/2018 Pump Intake Depth Below Top of Well Casing:103 feet Pump Manufacturer's Name: MYERS Pump Model:8 GPM Pump Size 1/2 hp Pitless Adapter Burial Depth: 13 feet Pitless Adapter Manufacturer's Name: CAMPBELL Pitless Adapter Installer: UNKNOWN Well Disinfected Upon Completion?Q Yes ❑ No Method of Disinfection: RECIRCULATION Comments: Pump Installer Name: WHEATON WATER WELL INC 1190 N.WASILLA FISHHOOK RD WASILLA,AK 99654 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP171366 Work Type: WellSeptic Initial Tax Code Number: 05153138000 Site Legal Address: RICLIN LT 1 G:1462 Site Mailing Address: 24826 MILTHERRIE CT, Chugiak Owner: TROY DAVIS HOMES INC Design Engineer: FORGE ENGINEERING This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date: Expiration Date: fes. III I J. I)cl)artment 12/27/2017 12/27/2018 Lot Size in Sq Ft: 52798 Total Bedrooms: , `3 Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 17 / l &/ I S CO # I : Re-'qi Se 4 TU 3 be8roo,n 's -q 4� G Received By: / Date: Issued By: Date: 12 02 o201 Municipality of Anchorage P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax(907) 343-7997 http://www.muni.orq/Onsite Development Services Division On-Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** Waiver#: OSV171156 COSA#: Permit#: OSP171366 PID#: 051-531-38 Legal Description: Riclin Lot 1 Engineer: Forge Engineering Applicant: Troy Davis Homes, Inc. Your request for a waiver of the required 50 feet horizontal separation from the absorption field to the excessive slope has been approved. The approved separation distance for the primary drainfield is 28.0 feet. The approved separation distance for the alternate drainfield is 0.0 feet. See engineer's narrative and profile drawings for justifications. This waiver approval applies to the proposed absorption fields only. Any other future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. 17 The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. n Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. ® Adjacent properties are not affected by this waiver. Waiver is Granted: X Waiver is not Granted: Date: 12/2?/2o1 7 Approved by: OW4 CZ)iT Jv Name of Reviewer **** VARIANCE/WAIVER REVIEW **** MUNICIPALITY OF A;! Community Development Department Development Services Division On -Site Water & Wastewater Program ANCHORAGE Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 051-531-38 Property owner(s) Troy Davis Homes, Inc. Day phone 310-2501 Mailing address 1689 Goose Bay Road #400 Wasilla, AK 99654 Site address 24826 Miltherrie Chugiak, AK 99657 Legal description (Sub'd., Block & Lot) RICLIN, LOT 1 Legal description (Township, Range & Section) Lot Size 52,798 Sq. Ft. Number of Bedrooms Three (3) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial RSingle Family (SF) ❑X (w/wo AD U) Septic Tank ❑X Upgrade ❑ Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Wellx❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: t� 1 urcLu��,•uzQo�, S10py— > cllk' 4-- Distance:-) 81 istance:)$r 4 Qi I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. ?V Cf- aC� (Signature of property owner or authorized agent) Permit/Rush Fees: I q Date of Payment: Receipt Number: 0 5 q � y Permit No. 0 S `P 1 "I 13 (0 lc Permit App_-'- : !–'.,:c Waiver Fees: * ) 15 Date of Payment: .I -A a 1 Receipt Number: $ O O k�) Waiver No. 0 �V i 'VI 1 1 5 C:a�1 IOEONGINEERING PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) July 13, 2018 Municipality of Anchorage Development Services Dept- On -Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Riclin Sub, Lot 1 Septic system design and permit application Dear On -Site Services Engineer: The owner of the above lot intends to build a 3 -bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any wells, whether on this lot or adjacent lots. Drainage arrows are shown on the site plan showing the grade and direction of flow. The drainage pattern in general will not be changed by the construction. The test holes placed on the lot indicate sandy gravel. No groundwater or bedrock was found down to 11.5-16.5'. The percolation rate was determined to less than 5 min/in. Test Hole No. 3 absorbed water faster than 1 minute per inch, but the proposed absorption trench is designed and proposed for construction outside the influence of Test Hole No. 3. An application rate of 1.2 gpd/sf was used in the design of the absorption system. We are proposing to place a new 1,000 -gallon septic tank with 2 wide absorption trenches each 5' wide x 20' long x 4' effective depth. The elevation of the distribution line will be 6' below the surface for a total depth of 10'. Soil will be mounded .5' above the trench. A minimum of 3' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot slopes moderately in general, between 25-30% to the northwest. A slope waiver request is included with this submittal. The new trenches will be constructed parallel to the slope as much as possible. It will be a minimum of 100' from all wells and surface water, and more than 5' away from the septic tank. The alternate site is located more than 12' away. If the system is constructed as designed, it will have no adverse impact: • On the wells in the area or those to be constructed in the future. • On existing septic systems in the area or those to be constructed in the fixture. • On reserve space on any lots located in the area. • On drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments OF . 44'4t f. rA � u / I♦ �•' 49?H a........ .. go, .......... ............... �� ,MICHAEL E. ANDERSON . 10 ;-P'.� CE - 438147 ® CO ••.e..•• 33' SECTION LINE EASEMENT —� - NO CONFLIC OR SEPTIC ALTERNATE /III-NIT�P,TE F SYSTEM X 4' EFFECTCT RICLIN SUBDIVISIONLOT 1 WELL j / / ! / SS S A Lcr-1 11 \ 40' UTILITY ,&/PR ATE \ ACCESS'EASEMENT//- Co # 1 1 7-4 MT G0 `�'— L� / I EXISTING ��.. �o MT- CO \ -BORN HOME T 1 / SEP 1C AREA C FS FCO I / L� TH#4`2CO SVSV - 1,000 GALLON LN J/ �T�E �EPTIC /25 -BUFFER LOT 5 - -�' LANDSCAPING- T EASEMENT CUN RIOUM NO CONFLICTSWITE LS NO CONFLICTS WITH WELLS OR'/SEPTIC SYSTEM. �� I I OR SEPTIC SYSTEM. J NO SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM LEGEND �r�.�P• •; f,��+ CO - CLEANOUT ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS 2C0 -DOUBLE CLEANOUT / /t� • • E 438PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC FCO -FOUNDATION CLEAN( • ' FS - FLOW SPLITTER VALVE �• ��.:Michael E.derson�SYSTEMS. MH -MANHOLE -o . • • 0 50 100 FEET MT - MONITORING TUBE it PROFESSIONp SV - SEPTIC VENT 1"=50' TH - TEST HOLE RICLIN SUBDIVISION, LOT 1 DESIGN FACTORS: 450 GPD PEAK FLOW PERK RATE: 1.5 MIN/IN APPLICATION RATE: 1.2 GPD/SF SYSTEM REQUIREMENTS: 5' WIDE SHALLOW TRENCH SYSTEM 1,000 -GAL SEPTIC TANK 450 GPD / 1.2 GPD/SF / 5' WIDE @.5 RED. FACTOR = 37.5 LF TRENCH LENGTH co# I THEREFORE: CONSTRUCT 2 ABSORPTION TRENCHES EACH 20' LONG x S WIDE x 4' EFFECTIVE DEPTH. FLOW LINE ELEVATION IN EACH TRENCH TO BE 6' BELOW ORIGINAL GROUND SURFACE. TOTAL DEPTH TO BE 10' BELOW EXISTING GROUND. PROVIDE 3' COVER OVER TRENCHES AND 4' COVER OVER SEPTIC TANK, OR 2" INSULATION WITH 2' COVER. V PERFORATED PVC ;HOLES DOWN) DRAINFIELD ROCK 4' TO GROUNDWATER 6' TO BEDROCK OR IMPERMEABLE LAYER TYPICAL WIDE TRENCH SECTION (NO SCALE) NOTES: GRADE AREA OVER TRENCH TO DRAIN AWAY MIN 6SEPARATION FROM BEDROCK MIN 4' SEPARATION FROM GROUNDWATER MIN 100' SEPARATION FROM NEARBY WELLS MIN 100' SEPARATION FROM SURFACE WATER OR STREAMS MUNICIPALITY OF ANCHORAGE `y., \�\[\��, DEVELOPMENT SERVICES DEPARTMENT '�.. •'•' I�ll1 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 j* TM �; .,A SOILS LOG AND PERCOLATION TEST Benja n Schiller . ' i<''*'. CE 12592 ..4`�/� LEGAL I PERFORMED FORNORTHERN EXCAVATING ‘t%9e PROFES*.....'...'� DATE: 08/19/17 PROJECT No.: \\\�� -' PARCEL ID#: 051-531-38 TECHNICIAN: J. MILLETTE Professional Engineers Stamp: DEPTH TEST HOLE 1 (feet) SLOPE SITE PLAN 2 ..-:.-..'; . 4 ; }':' ' 5 ..4':^"i•.'r.• SEE SITE PLAN 6 ,'':',•.�.:';):: SANDY GRAVEL W/ ' TRACES OF SILT 7 ',,j,-.'. ?, t 10 1:,'' '' 1"7 WAS GROUND WATER ENCOUNTERED? NO •,••,:.•:,2?-,L.,- IF YES eo WHAT DEPTH? - 1 1 t'•..':''• . .. DEPTH OF WATER AFTER MONITORING: NONE a ��?;• DATE OF MONITORING: 8/20/17 12 E GROSS TIME NET TIME DEPTH TO NET DROP 13 DATE READING (MINUTES) (MINUTES) WATER (INCHES) (INCHES) 14 08/19 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 I 3:56 0 16 2 4:20 24 6.00" 6.00" 3 4:21 0 17 4 4:45 24 6.00" 6.00" 18 5 4:46 0 19 6 5:10 24 6.00" 6.00" 20 PERCOLATION RATE: 4 (MIN/INCH) PERC.HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 2.5 FT. and 3.5 FT. COMMENTS: MUNICIPALITY OF ANCHORAGE •��N.\\N‘ DEVELOPMENT SERVICES DEPARTMENT r OF 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 ...lb.. �c -'9*�l SOILS LOG AND PERCOLATION TEST % rBe:-F,.. min Schiller . � LEGAL DESCRIPTION: RICLIN LOT I t♦e,�Fc�l••• •CDE 12592 ••.1":: PERFORMED FOR: NORTHERN EXCAVATING 1�1F9F°PROFESSIO....o+� DATE: 08/19/17 PROJECT No.: `\\\\\��~ PARCEL ID#: 051-531-38 TECHNICIAN: J. MILLETTE Professional Engineers Stamp: DEPTH TEST HOLE 2 (feet) SLOPE SITE PLAN •, 2 .•u. ��..; 4 . v::..f. 4 ;,..j *i 5 ':,t•' ;.•,,..t+ SEE SITE PLAN 6 .'' � •'a• 'r • ; SANDY GRAVEL W/ , 1 :•rA.:1A:::i' ... :•i.;.:, TRACES OF SILT . 10 ,: "... . WAS GROUND WATER ENCOUNTERED? NO ,:s.:::.!..:../.. IF YES @ WHAT DEPTH? - 11 1'•,••, DEPTH OF WATER AFTER MONITORING: NONE :..,;': ,. DATE OF MONITORING: 8/20/17 '''�''•? DEPTH To '•";• :•';.7':' DATE READING GROSS TIME NET TIME WATER NET DROP (MINUTES) (MINUTES) (INCHES) (INCHES) 14 08/'9 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 1 4:26 0 16 2 4:51 25 6.00" 6.00" 3 4:52 0 17 4 5:17 25 6.00" 6.00" 18 5 5:18 0 19 6 5:43 25 6.00" 6.00" 20 PERCOLATION RATE:4.16 (MIN/INCH) PERC.HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 2 FT. and 3 FT. COMMENTS: MUNICIPALITY OF ANCHORAGE ����\\\� 4� of Ai ii DEVELOPMENT SERVICES DEPARTMENT ��Q• • , ,f.9'+ 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 meg' �4, ' SOILS LOG AND PERCOLATION TEST / „ ,, Benja Schiller 1+� � F'''. CE 12592 •,4 Iii LEGAL DESCRIPTION: RICLIN LOT I Ta ,••. DKis.m �+7 .••, PERFORMED FOR: ll\FOPROiL'SkNa DATE: 10/17/17 PROJECT No.: _ \\\`��`~ PARCEL ID#: 051-531-38 TECHNICIAN: J. MILLETTE Professional Engineers Stamp. DEPTH TEST HOLE 3 (feet) 1 .• 1+ J.• ' . I' OB SLOPE SITE PLAN 2 .b?::::‘,........:.:.;::: 4 ':` ` . 5 1;-;: 1::: ;; SEE SITE PLAN $51 ,...,•. ., �,r•: WELL-GRADED SAND • s''j'• '• W/ SILT AND GRAVEL .``;„'f:.,:...t.:..; ti (SW-SM) 7 .` •, • ,y` 9 1 O .'-.1.1:.,:. .t , WAS GROUND WATER ENCOUNTERED? NO ''` '";^' IF YES @ WHAT DEPTH? — 1 1 ?• ''r .< DEPTH OF WATER AFTER MONITORING: NONE 75 .,::.;:,;;1.,.� DATE OF MONITORING: 11/07/17 st;{d:i,;•.:}: '1`'• ::'.;:`:' DATE READING GROSS TIME NET TIME DEPTH TO NET DROP 13- ;',4',^+ ::.••-: (MINUTES) (MINUTES) (INCHES) .fi.•••r (INCHES) 14 �: `�. 11/07 TEST HOLE PRESOAKED PRIOR TO TESTING: f"!y I I:30 0 15 ..;r:;,.:—...,:i:�• <:: -'a 2 1:31 0:48 6.00" 6.00" 16 ...:,:;..,!:!::: ::.•,: ..: :.�; :n. a f. 17 x."� 9 1:40 0 18 10 1:42 1:04 6.00" 6.00" 19 I I 1:43 0 20 12 :44 1:04 6.00" 6.00" PERCOLATION RATE: .18 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 3 FT. and 4 FT. COMMENTS: TEST WAS PERFORMED 6 TIMES. INTERMEDIATE RESULTS NOT SHOWN BUT WERE EQUIVALENT MUNICIPALITY OF ANCHORAGE 4� ��\\ l DEVELOPMENT SERVICES DEPARTMENT i�P •'' 'q��'1+ 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 j a?'% ��' •'9 +� , SOILS LOG AND PERCOLATION TEST .. . . ... u Benj. •Schiller : LEGAL DESCRIPTION: RI CL I N LOT I �+fk • C 12592 ••�A i� I liF m PROFESSION•\.'' � PERFORMED FOR: \\\\"`'" DATE: 10/17/17 PROJECT No.: PARCEL ID#: 051-531-38 TECHNICIAN: J. MI LLE TTE Professional Engineers Stamp: DEPTH TEST HOLE 4 (feet) - I' OB SLOPE SITE PLAN 2 °' •�•'•,1,, 5 :;r : :. SEE SITE PLAN 6 j' .4 ',.•r;; WELL-GRADED SAND ' '''' W/ SILT AND GRAVEL 7 ::::•:', :;.;:i.7,!':: ;:';fy ; (SW-SM) ,�h 8 • ',1.i 9 , t 10 }''• 'rWAS GROUND WATER ENCOUNTERED? NO i'i•':":1",. :1 I, • IF YES @ WHAT DEPTH? - 1 1 '^,,'.. ••.c DEPTH OF WATER AFTER MONITORING: NONE ?�$j '•�<.. .•r' DATE OF MONITORING: II/07/17 �+,IL'L J. 12 ::. r„ :•::. E _ `• „i,..;.:: DEPTH TO '1` ' '� ' DATE READING GROSS TIME NET TIME WATER NET DROP 13 '�j� :::>i (MINUTES) (MINUTES) (INCHES) ,.:•.=•:.„::::::;.:: (INCHES) 14 :::.'.1::,:',..7.:::...i.. 11/07 TEST HOLE PRESOAKED PRIOR TO TESTING: f:`-... I 12:30 0 15 ,:,:. 16 2 12:37 6:49 6.00” 6.00" `I. •:'. 17 9 1:06 0 18 10 1:14 8:05 6.00" 6.00" 19 II 1:15 0 20 12 1:24 8:05 6.00" 6.00" PERCOLATION RATE: 1.5 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 3 FT. and 4 FT. COMMENTS: TEST WAS PERFORMED 6 TIMES. INTERMEDIATE RESULTS NOT SHOWN BUT WERE EQUIVALENT Map ) ' GE ENGINEERING PO BOX 240773 ANCHORAGE,AK 99524 522-7773 677-7766(FAX) December 15, 2017 Municipality of Anchorage Development Services Dept- On-Site Water& Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Riclin Subdivision, Lot 1 Separation Distance Waiver Absorption Trench to Excessive Slope Dear On-Site Services Engineer: Surface area available on the subject lot for placement of a septic system is limited by the location of the well and the placement of the house. In addition, the surface slopes on the lot vary from 25% to 35%. A waiver is therefore necessary to allow the new absorption trench and alternate site to be constructed within 50' of a break in grade greater than 25%. Both the primary absorption system and alternate site are proposed for construction at 5.5' below the surface. The primary site is located on slopes less than 25%, but the slopes fronting the system are steeper. The alternate site is located on a slope greater than 25%. Fill will be required on the slope fronting the alternate site to prevent the imaginary 25% slope from the edge of the absorption trench from daylighting less than 35' down slope from the trench. No fill is required fronting the primary site. The average depth of the fill is 1'. The accepting soil at the absorption system locations is sand with silt and gravel with percolation rate of 1.5 minute per inch. Little or no migration of effluent is expected. We therefore request the primary absorption system and alternate site be constructed on a slope at or more than 25%. Sincerely, Benjamin Schiller, P.E. Attachment ,*4911_1ff 9* ' 6 enja Schiller $ PF•• C 12p2 •c(``Q� csl'• la�16�1:1-t .�G�i 1,` :0;1;iOF SS10��4 35' 415' — — 1 1 410' — — — --- / .-- / --- a --- —n 405' •N• G< -25% 35' 400' — — �— r _I ___I .--- .-- 395' 395' — • 0 5' 10' 15' 20' 25' 30' 35' 40' 45' 50' 55' 60' 65' 75' 80' gsk0 RICLIN SUBDIVISION i*•49TM' %\ *1 / LOT 1 i ••••- ••�I' SLOPE ASSESSMENT • Benj.'in Schiller . / �I�F • CE 5292 •••``J SECTION A i'k 0PROFESSIO '..c? 420' Q` G`0Und, 066.1n 415' - — y � 410' — — Fill Material - 23' 405' — -- i 400' 35' I - I 395' 0 5' 10' 15' 20' 25' 30' 35' 40' 45' 50' 55' 60' 65' 75' 80' P• 444 RICLIN SUBDIVISION *'49 TM Y *t�l� LOT 1 Benja •Schiller : SLOPE ASSESSMENT v+AP.•. C 12592 .•• • r;• X15.2017 • � S ECTI 0 N B ll`F�PROFESSIONP�'.� ESTATES Lot 1 TONJESS Lot 2 • 40' UTILITY & PRIVATE TBM - TOP OF ACCESS EASEMENT 5/8" REBAR N 89'53'15"E 220.05' ELEV. 409.5 o N 387.8/ I _ 1 387.8 "•.._.. ` ` \k\ 40 L.F. - 18" CMP 408.0 x b. co ��iVLEGEND SEE ENGINEER'S PLANS FOR 104.8 EXISTING ELEVATION WELL & SEPTIC DETAILS DRIVEWAY 103.0 PROPOSED ELEVATION // 12 0 IT ,: 78 1' SURFACE DRAINAGE T 20.0' I LOT COVERAGE = 0.5% Z 0 • N GARAGE I�ROOF OVERHANG (/1 O \ E.L. 415.0 I O O t.711-1c; R o IC q o NI- 10.0' 2iD Oo Cn M L".csio' F.F. EL. 416.8 IE Lot 1 n; Lot 2 N 87.8' L I 54.0' 1- / tv O K 47:14 G / 0 ((( EXISTING PROPOSED O D /� O 415.0 A 415.0 416.3 B 414.8 417.E C 414.8 418.7 0 414.8 \ 419.8 E 414.8 \ 420.6 F 414.8 419.3 H 414.8 \ 418.0 H 414.8 416.8 I 414.8 Lot O 415.5 J 414.8 1 415.0 K 414.8 414. L 414.8 1.21 Acres 413.2 M 414.8 412.4 N 414.8 411.8 0 414.8 412.0 P 414.8 413.7 0 414.8 414.6 R 414.8 412.5 S 414.8 25' BUFFER 408.7 T 414.8 LANDSCAPING 407.8 U 415.0 411.8 V 415.0 422.2 448.2 \ EASEMENT 446 2\ - - 413 6 W 415.0 - - - S 89'53'15"W 219.93' I \ I Lot 4 I Lot 5 PLOT PLAN AS BUILT X SCALE 1" = 40' GRID _ NW 1462 Project No. 17-303/B1 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates , inc . (907) 522-6476 Phone 4�oF00‘(907) 522-4625 Fax oaOr �0Professional Land Surveyors kenOlangsurvey.com 0'`�jonathanOlangsurvey.com 0 I hereby certify that I have surveyed the following described property: 'Cc ' �� Q Lot 1, RICLIN SUBDIVISION (Plat No. 2005-37) i .� 4 9rH �� • *�O Anchorage Recording District, Alaska, and that the improvements situated thereon are 0 I VA within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed �o KENN H LANG'' 0 premises and that there are no roadways, transmission lines or other visible OA c^� . o easements on said property except as indicated hereon. V ,} }'{ O� Q1 11F •'..LS-5202.•'' c; Dated this the Day of • L'I w' _, , at Anchorage, Alaska �,o NO o 4�4RO SSIONAI-©� It is the responsibility of the owner to determine the existence of any easements, DOpppoo5z" covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963 Development Services Department r Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 051-531-38-000 Expiration Date: Legal description RICLIN LT 1 Site address 24826 MILTHERRIE CT Chugiak AK 99567 10/20/2023 Current property owner(s) GLASPELL BRIAN SCOTT MELLING HEIDI X The On-site system(s) is/are approved for 3 bedrooms Conditional approval for Comments or advisories: bedrooms, with the following stipulations: Original Certificate Date: 7/20/2023 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory X Tank Age Advisory Arsenic Advisory Other COSA Approval_June 2022 MUNMPAUTY OF ANCHORAGE RAGE Development Services Department c.7 Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 051-531-38 Complete legal description Ridin Lot 1 Location (site address) 24826 Mlltherr'ie Court, Chugiak, AK 99567 Current property owner(s) Brian GlaSpell & Heidi Helling Day phone (907) 370-3308 2. ON-SITE SYSTEMS SIZED FOR 3 BEDROOMS 3. TYPE OF WATER SUPPLY: 0 Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ❑■ Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑■ Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age 6 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench ®❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ .5 Date of Payment zz ca3 COSA # 0 S C_ 7- I3) � Waiver Fee $ Date of Payment Waiver # COSA Application—June 2022 Riclin Lot 1 051-531-38 5.0+ 7/18/18 109 109 5.24 18+ 7/4/23 Forge Engineering 79 6/21/23 49" 7/7/23* *Sanitary Pumpers 8/15/18 *9.8/9.5 *5.9/5.9 N/A N/A N/A 7/4/23 732 30 >450 48 2/0 *Trenches listed north/south Benjamin Schiller, P.E.7/5/23 (907) 522-7773 www.muni.org/onsite Nitrate Advisory Certificate of On -Site Systems Approval # OSC231238 Subdivision: Riclin, Block: , Lot: 1 A water sample revealed a nitrate concentration of 5.24 milligrams per liter (mg/Q. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Since nitrates are known to slowly increase, we recommend you monitor the water quality. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. wx Mailing A�Idress P O Box X96650 � Anchorage, Alaska 99319 6650 � www mum org 70 MUNICIPALITY OF AN '►6 ' , , fr 119 Development Services Department " " a P e: 907-343-7904 On-Site Water & Wastewater Section .x: 907-343-7997 / , Certificate of On-Site Systems Appt'oVah Parcel I.D. 051-531-38 Expiration Date: Z2—( C( 1. GENERAL INFORMATION Complete legal description Riclin Lot 1 Location (site address) 24826 Miltherrie Court Current property owner(s) Troy Davis Homes, Inc Day phone 907-357-9394 Mailing address 1689 Knik Goose Bay Road, Wasilla, AK 99654 Real estate agent Day phone 2. TYPE OF DWELLING: O Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well Private Septic ❑ Water Storage ❑ Holding Tank U Community Well [ Community I Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ 120. 00 Waiver Fee $ Date of Payment 02 z0 I1 Date of Payment Receipt Number 01 fl Receipt Number COSA# C i g I 0 S o Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Forge Engineering Phone 907-522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage AK 99503 Engineer's Printed Name Michael E. Anderson, P.E. Date 2/19/19 44,q, • ar 6. DSD SIGNATURE to �� �� • 49th tot System #1 Approved for .11. �4CCHAEL.E ANDERSON /. y pp bedrooms 0 MICHAEL E. ANDERSON +fss� No. CE-4381 System #2 Approved for bedrooms +ip,<%•tip•„2/19/19���.o•*c���► • Disapproved ++IN.FES• ;;io Conditional approval for bedrooms, with the following stipulations: ON-SITE WATER AND C WASTEWATER o PROGRAM S /3on�'1/7' \h`4�n SFR By: ` t `^^ Original Certificate Date: L- 2Z-( The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA)based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet COSA Checklist Legal Description: Riclin Lot 1 Parcel ID: 051-531-38 If more than 1 septic system on lot: COSA Checklist# of Structure served by this system A. WELL DATA ❑� Well log is filed with Onsite(or attached) Well production at time of test 10 gpm Date drilled 7/18/18 Water storage tank volume N/A gallons Total depth 109 ft Well disinfected for coliform test? 0 Yes No Cased to 109 ft Coliform bacteria is Negative ❑■ Sanitary seal is functioning correctly Nitrate mg/L ❑■ Nitrate less than MRL(ND) ❑t Wires are properly protected Arsenic ug/L ❑■ Arsenic less than MRL(ND) Casing height(above ground) 24 in. Collected by Wheaton Water Wells Date of flow test for COSA 7'1818 Date of Sample 12'19/18 Static water level at beginning of test 91 ft. Comments B. TANK DATA C. LIFT STATION Age of tank(s) 0 years 0 Required maintenance completed Tank type/material s'°"'"" Age of lift station years Measured operating fluid level in septic tank New Lift station material ❑■ Standpipes/foundation cleanout per record drawing Comments: Date of pumping N/A D. ABSORPTION FIELD DATA 5 -Wide Which system tested(date installed) 8/15/18 Adequacy test date New ❑� ALL standpipes present per record drawing Results ❑Pass For bedrooms Total measured depth from grade 8.9/10.a ft(max) Fluid depth prior to test in Measured depth to pipe invert from grade 4.9/6.4 ft(min) Water added gal 0 N/A—pressurized field New depth in ■❑ Monitor tubes go to bottom of effective. If not, state Elapsed time min depth into effective ❑� Code-required soil cover over field Final fluid depth in 0 System presoaked Absorption rate gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment(past 12 months) date of test) Gallons introduced N/A gallons If yes, enter date Comments/Deficiencies: • COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot> 100' Community Sewer Manhole/Cleanout> 100' 0 Yes if No ft p✓ Yes if No ft Neighboring Tank > 100' 0✓ Yes if No ft Private Sewer/Septic Line>25' ❑✓ Yes if No ft Absorption Field on Lot> 100' 0 Yes if No ft Holding Tank> 100' 0 Yes if No ft Neighboring Absorption Fields> 100' Animal Containment> 50' 0✓ Yes if No ft 00 Yes if No ft Manure/Animal Excreta Storage> 100' Community Sewer Main > 75' 0 Yes if No ft I Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations> 10' 0 Yes if No ft Surface Water> 100' 0✓ Yes if No ft Property Line> 5' 0✓ Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' 0 Yes if No ft Private Wells> 100' 0✓ Yes if No ft Water Main > 10' ✓0 Yes if No ft Community Wells>200' 0 Yes if No ft Water Service Line> 10' 0 Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' [' Yes if No ft If absorption field is under driveway comment below Property Line> 10' 0 Yes if No ft Wells on Adjacent Lots: Water Main > 10' ✓0 Yes if No ft Private Wells> 100' E✓ Yes if No ft Water Service Line> 10' 0✓ Yes if No ft Community Wells>200' 0✓ Yes if No ft Surface Water> 100' ✓0 Yes if No ft F. ENGINEER'S COMMENTS _wisui>i>r4 G. ENGINEER'S CERTIFICATION .��`P-�� OF 44.�44 I certify that I have determined through field inspections and review i •e `4� �'•.• O of Municipal records that the above systems are in conformance with i 4• 49{h /\ - of MOA COSA guidelines in effect on this date. ; z. f . B ..„ .... .d • MICHAEL E. ANDERSON i a �v m �0�-J,'•. No. CE-4381 .•' -� r •y♦�f jf•j'•. 2/19/19 .•� C` 4p COSA Checklist yellow sheet . eb••�''••••••••.•••��P� .+� '°ROFESS' �••� 4 II Ustive ** COSA Checklist Legal Description: Riclin Lot 1 Parcel ID: 051-531-38 If more than 1 septic system on lot: COSA Checklist# of Structure served by this system A. WELL DATA ❑■ Well log is filed with Onsite (or attached) Well production at time of test 10 gpm Date drilled 118/18 Water storage tank volume N/A gallons Total depth 109 ft Well disinfected for coliform test? ❑ Yes No Cased to 109 ft U Coliform bacteria is Negative ❑� Sanitary seal is functioning correctly Nitrate mg/L ■❑ Nitrate less than MRL (ND) ■❑Wires are properly protected Arsenic ug/L 0 Arsenic less than MRL (ND) Casing height (above ground) 24 in. Collected by Wheaton Water Wells Date of flow test for COSA 7"8/18 Date of Sample 12/19"8 Static water level at beginning of test 91 ft. Comments B. TANK DATA C. LIFT STATION Age of tank(s) 0 years ❑ Required maintenance completed Tank type/material Age of lift station years Measured operating fluid level in septic tank New Lift station material ❑■ Standpipes/foundation cleanout per record drawing Comments: Date of pumping N/A D. ABSORPTION FIELD DATA 5 -Wide Which system tested (date installed) 8/1518 Adequacy test date New • ALL standpipes present per record drawing Results ❑Pass For bedrooms Total measured depth from grade 8 9110 4 ft(max) Fluid depth prior to test in Measured depth to pipe invert from grade 4.9/6.4 ft(min) Water added gal ❑ N/A—pressurized field New depth in ❑� Monitor tubes go to bottom of effective. If not, state Elapsed time min depth into effective Final fluid depth in ❑ Code-required soil cover over field ❑ System presoaked Absorption rate gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment(past 12 months) date of test) Gallons introduced N/A gallons If yes, enter date Comments/Deficiencies: COSA Checklist yellow sheet 12.2 No 20.0 HOUSE DETAIL i Scale: 1" = 20' N 0 —e.2.. .. ,' 1. PORCH'. ,. No O 0 9.8 ^> `•_✓ \ 2 STORY N RESIDENCE N NOTE: DUE TO SNOW & ICE COVER; THE LOCATION OF THE ASPHALT DRIVEWAY IS APPROXIMATE. 54.2' DECK o I 12.s' r _j.__ Lot 1 / I Lot 2 I / I i I 11 N 89'53'15"E 220.05' I / 40' UTILITY Sc PRIVATE—_, \ ACCESS EASEMENT — — 1_ / I M • I 0 . •o, .. �EASEMENTSECTION LINE 1 .PS? • ' .+ O WELL / z- a- N :;.. 4, o o :::..m., ow u! y U N 93.9' =I ' . r•fro Lot 2 N �. Ps''' / SEE HOUSE o 0 O I DETAIL o 0 70.1' 7 SEPTIC PIPES Lot 1.21 Acres in 30' VEGETATIVE BUFFER Ilo (PER CE R-7 ZONING) 25' BUFFER LANDSCAPING EASEMENT t S 89'53'15"W 219.93' I Lot 4 Lot 5 I— — 1 I— I 1 I PLOT PLAN AS BUILT X SCALE 1" = 40' GRID _ NW 1462 Protect No. 17-303/B5 11500 Daryl Avenue, Anchorage. Alaska 99515-3049 • Lang & Associates, inc. (907) 522-6476 Phone �OOppp (907) 522-4625 Fax o�OF Q `pp4 Professional Land Surveyors kenOlangsurvey.com v .,.........:16A .. •• q jonathanOlangsurvey.com o'CS Q I hereby certify that I have surveyed the following described property: .1;Q':•'. H ..:37 0 Lot 1, RICLIN SUBDIVISION (Plat No. 2005-37) 0* 49L ��ii * Anchorage Recording District. Alaska, and that the improvements situated thereon are 0 o within the property lines and do not encroach onto the property adjacent thereto, that no Improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other visible Q k '.. KENN 174 : 4rQ easements on said property except as Indicated hereon. 0 1.110iVI •' Q� ,,,c- �h ,,,, -•.L5-5202.•' ,,„, Dated this the Day of (V4`o h�bL , ' ` , , at Anchorage, Alaska ,o •••• a0o l kiktfFSSIONAt-to It Is the responsibility of the owner to determine the existence of any easements, DOpppoo� covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963