HomeMy WebLinkAboutSCENIC HEIGHTS LT 4Onsite File !icenic 4) 0 Heights ' Municipality of Anchorage On-Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181046 PID Number: 020-291-79 Dwelling: g Single Family (SF) E Duplex(D) ❑ Multiple(SF and/or D) Project: ❑■ New El Upgrade Name: ABSORPTION FIELD Robert P. & Donna L. Pierson Address ❑■ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound 1601 Abbott Rd Ste 102 Anchorage AK 99507 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 3 0.8 GPD/SF 10.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 2.0 Ft. 8.0 Ft. Scenic Heights 4 Fill added above original grade Gravel length Township Range Section 1.9 Ft. 36 Ft. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES 3.0 Ft. Ft. To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches Tank Field Lift Station Tank Line From 576 Ft2 1 Ft. Well >100' >100' N/A N/A >25' TANK ❑ Septic ❑ S.T.E.P. ❑ Holding El Other Manufacturer Capacity Surface Water >100' >100' N/A N/A , Anchorage Tank 1000 Gal. Material Number of compartments Lot Line >10' >10' N/A N/A Steel 2 NA Foundation >10' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Pump on level at Pump off level at High water alarm at Remarks in. in. in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank D2665Tank to D3034 Installer drainfield Sanders & Sanders Drainfield D3034 CO/MT D3034 Inspector J. Millette BENCH MARK (Assumed elevation) 100 ft Inspection 151 5/04/18 2"d 5/04/18 Location and description dates: 3rd 4th Top of South corner of foundation. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp .� v, Conditional Approval: Date r��Q"�`.•' AL40-..-.1.911.�cs,�k k� i '49TH i\ * , .. .r.- ... Be* 7 •. chiller 'CE 12592 ••`4 /�yIo.•. l . 10/12/18 •.•. — Approved ataA Cauc( C� To, &time/ Date /d 15 1 & II�FDPROFESS10NaN'f'4?- Inspection Report_9-1-12.doc SCENIC HEIGHTS LOT 4 PERMIT # OSP181046 PID # 020-291-79 BLOCK 2 LOT 37, WELL I 1 "-- 7,, I t LOT4 I I W I! LOT 3 > 1 E / .3-BDRM HOME w/ 0 N 'I iii 0 • 0 w LLJ a_ : TH#2 It o 1000-G LSEPTIC TANK 44 CD w w •• # vi • m ® • C01 TH#10 V2CO I . m414 : Qw- Ik- .2 w • zC C�•\ ALTERNATE SITE w t0 1C o N 10'T&E E.ASEMENT \ 36'LONG x 3'WIDE,8' I \ EFFECTIVE DEPTH ABSORPTION TRENCH \ I I c ® 4 LOT 2 ( LOT 3 A ' A B '�OF At... 46\kkt FCO 29.1 5.9 LEGEND ."� ''' .• SV1 32.5 12.0 CO-CLEANOUT /'''g' .• ��� '�T�� SV2 36.7 17.0 200-DOUBLE CLEANOUT %*:49 Di /\ '*9, 2C0 42.1 r9:68- 0 3.6 / , — FCO-FOUNDATION CLEANOUT "" ems'—•' "' / C01 40.1 39.8 0 ...t ...../ MT 43.0 37.8 FS-FLOW SPLITTER VALVE / '. Benja 7 chiller j 0 50 100 CO2 59.5 32.1 MH-MANHOLE #00-••... C«82592 .•• (44/ MT-MONITORING TUBE I♦ = = FEET SV SEPTIC VENT 1111 PROFEss c ' - 1"=50' TH-TEST HOLE \\\74*--46' SCENIC HEIGHTS LOT 4 PERMIT # OSP181046 PID # 020-291-79 oN o o > > 0 LL CO Cn N — — 99.1 — — — — � i 95.1 94.5 - 1000 GAL 94,35 SEPTIC TANK v 90.3 97.4 FINISH GRADE 02/ 95.5 ORIGINAL GRADE O 00 _ ///`` / ---- _— — — — 93.5 =_-_---,_-_-_-_=,_.=---,-_-,-,__ --- ------------ -4.4 — 93.5 DRAINFIELD ROCK �� 85.5 36' _\- 79.5 NO GROUNDWATER 4/12/18 II— i _A9 7H 1' �9*+0 Benjamin Schiller : PROFILE AS-BUILT ri� �F;s•esp. E12592 2018 .. ��� (NO SCALE) 1kklk ,;ROFESSIONP-,.c"..... Alpine Drilling & Enterprises Well Log Permit Number: #SW181046 Date of Issue: 4-17-18 Parcel Identification Number: 02029179000 Date Started: 6-3-18 Date Completed: 6-5-18 Is well located at approved permit location?x Yes ❑ No Legal Description: Scenic Hieghts Lot 4 Property Owner Name& Address: Robert& Donna Pierson Crown Pointe Borehole Data: Depth (ft) Method of Drillingai Soil Type, Thickness & Water Strata From To ❑ r rota r5' ❑ cable tool Casing type:steel stick-up 0 2 Wall Thickness: .250 inches gravelly silt 2 54 Diameter: 6 inches Depth: 111 feet silt 54 59 Liner Type: Diameter: inches Depth: feet gravelly silt 59 61 Casing stickup above ground: 2 feet gravelly cobbly silt 61 107 Static water level (from ground level): 232 feet bedrock 107 426 Pumping level: 440 feet after 8 hours pumping 1_5 gpm Recovery Rate: 1_5 gpm Method of Testing: air lift Well Intake Opening Type: ❑Open End x Open Hole ❑ Screened Start feet Stopped feet ❑ Perforations Start feet Stopped feet Grout Type: bentonite granules Volume: 2 bgs Depth: Start 0 feet Stopped ? feet WATER gUALIN TESTING Pump: Intake Depth feet :aliform eO CO1M00mL Pump size hp Brand Name ; Nitrates Z,•2. mg/L Well Disinfected Upon Completion? x Yes❑ No Arsenic ug/L Method of Disinfection: chlorine tablets Comments: Well Driller: Alpine Drilling&Enterprises PO Box 110496 Anchorage AK 99511 MUNICIPALITY OF ANCHORAG Development Services Department (� } `m..41 )1 Phone: 907-343-7904 On-Site Water& Wastewater Section `� Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: 181046 04 17 _18 Date of Issue: - Parcel Identification Numbei PZ.o_;01 qv() 7_ Gy(')��' Lot4 Description Block Lot Property Owner Name& Address: 3 Robert&Donna Pierson Scenic Heights Crown Pointe P.O. Box 112313 Anchorage,AK 99511-2313 Pump Installation Date: 08 -09 -2018 Pump Intake Depth Below Top of Well Casing: 417 feet Pump Manufacturer's Name: Goulds Pump Model: 5HS10 Pump Size: 1 hp Pitless Adapter Burial Depth: /A feet Pitless Adapter Manufacturer's Name: N/A Pitless Adapter Installer: NSA Well Disinfected Upon Completion? ! Yes ❑ No Method of Disinfection: chlorine tablets Comments: Please save for COSA. Pump Installer Name: Company: Aarow Pump & Well Service, LLC Mailing Address: P.O. Box 110496 City: Anchorage State: AK Zip: 99511 Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation. MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP181046 Work Type: WellSeptic Initial Tax Code Number: 02029179000 Site Legal Address: SCENIC HEIGHTS LT 4 G:3637 Site Mailing Address: 5733 GREECE DR, Anchorage Owner: PIERSON ROBERT P & DONNA L Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft Total Bedrooms: JAI C I -r Dcpartnlcilt 4/17/2018 4/17/2019 43628 0 Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: t hj Issued By: Date: 7 119 Date: ` 7 3 E PIo­ns MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 020-291-79 Property owner(s) Robert & Donna Pierson Day phone _ Mailina address 1601 Abbott Rd, Suite 102, Anchorage, AK 99507 Site address NHN Greece Drive Legal description (Sub'd., Block & Lot) Scenic Heights, Lot 4 Legal description (Township, Range & Section) Lot Size 43,628 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field 0 Initial ❑X Single Family (SF) ❑X (w/wo AD U) Septic Tank ❑X Upgrade ElDuplex (D) ❑ Holding Tank ❑ Renewal ElMultiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 4 -N9 Date of Payment: i/ 11 119, Receipt Number: Permit No. 0S I Permit App__- : .'-:c Waiver Fees: Date of Payment: Receipt Number: Waiver No. PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) April 13, 2018 Municipality of Anchorage Development Services Dept- On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Scenic Heights L4 – NHN Greece Drive Septic system design and permit application Dear On-Site Services Engineer: The owner of the above lot intends to build a 3-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes moderately away from road towards the southwest corner of the lot. The slopes in general range from 10-20%. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Drainage arrows are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. It will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 16’ away. Please refer to the attached test hole logs, soils lab analysis, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE 4/13/18 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181046, Rebecca Carroll, 04/17/18 10.4%13.0%15.1%8.9%11.4%11.6%15.3%9.5 % ALTERNATE SITE FCO 10050 0 FEET 1"=50' 36' LONG x 3' WIDE, 8' EFFECTIVE DEPTH ABSORPTION TRENCH 3-BDRM HOME WELL 1000-GAL SEPTIC TANK NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND CO MT TH#1 GREECE DRIVESCENIC HEIGHTS LOT 4 Apr 13, 2018 10' T&E EASEMENT 10' T&E EASEMENT50' SECTION LINE EASEMENTUNDEVELOPEDTH#2 CO 2CO CO CO 16.0 10.1 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181046, Rebecca Carroll, 04/17/18 SCENIC HEIGHTS LOT 4 DESIGN FACTORS: SYSTEM REQUIREMENTS: 450 GPD PEAK FLOW PERK RATE: 11.4 MIN/IN APPLICATION RATE: 0.8 GPD/SF 3' WIDE DEEP TRENCH SYSTEM 1000-GAL SEPTIC TANK TYPICAL DEEP TRENCH SECTION (NO SCALE) 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 3' 6" 6" 1'-6" 8' Apr 13, 2018 NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY BOTTOM OF TRENCH: 10' BELOW GRADE FLOW LINE ELEVATION: 2' BELOW GRADE TOP OF TRENCH: 0.5' ABOVE GRADE 450 GPD / 0.8 GPD/SF / 8' DEEP / 2 SIDES = 35.2 LF TRENCH REQUIRED (36 LF SPECIFIED) INSULATION Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181046, Rebecca Carroll, 04/17/18 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 1 SLOPE SLOPE SITE PLAN See Site Plan DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) Scenic heights Lot 4 3/27/18 J. Millette Development Services Department 4700 Elmore Road Anchorage, AK 99519-6650 Municipality of Anchorage DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH OF WATER AFTER MONITORING: IF YES @ WHAT DEPTH? NO - NONE 3:30 3/30 7-5/81 11.4 6 3.5 4.5 4:00 30 10-9/16 2 1' OB SILTY SANDY GRAVEL (SP) 020-291-79 CROWN POINTE HOMES 3/30 4:01 3 4:31 30 4 4:32 5 5:02 30 6 2-15/16 2-7/810-1/2 Professional Engineers Stamp: Apr 13, 2018 4/12/18 7-5/8 2-7/810-1/2 7-5/8 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181046, Rebecca Carroll, 04/17/18 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 2 SLOPE SLOPE SITE PLAN See Site Plan DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) Scenic heights Lot 4 3/27/18 J. Millette Development Services Department 4700 Elmore Road Anchorage, AK 99519-6650 Municipality of Anchorage DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH OF WATER AFTER MONITORING: IF YES @ WHAT DEPTH? NO - NONE 3:45 3/30 4-1/21 8.9 6 3.5 4.5 4:15 30 7-7/8 2 1' OB SILTY SANDY GRAVEL (SP) 020-291-79 CROWN POINTE HOMES 3/30 4:16 3 4:46 30 4 4:47 5 5:17 30 6 3-3/8 Professional Engineers Stamp: Apr 13, 2018 4/12/18 4-1/2 7-7/8 3-3/8 4-1/2 7-7/8 3-3/8 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181046, Rebecca Carroll, 04/17/18 R(JSt* r fin 4 s�'a 9,�(l 1 8 9 10 ` Sit I . `06 ,, • • • Municipality of Ancho *IS° �4 On-Site Water and Wastewater Pro.? SEP (s ov8 (907) 343-7904 °' SAFETY ti �d 4, Certificate of On-Site Systems Ap. 020-291-79 9 Parcel I.D. Expiration Date: r(' /� �( 1. GENERAL INFORMATION Complete legal description Scenic Heights Lot 4 Location (site address) 5733 Greece Drive Current Property owner(s) Robert & Donna Pierson Day phone Mailing address 1601 Abbott Rd. Ste 102, Anchorage, AK 99507 Real Estate Agent Day phone 2. TYPE OF DWELLING: El Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: AI 1204 Date: 0/157/ COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ Waiver Fee $ Date of Payment `� f o '112 Date of Payment Receipt Number Qua lOb Receipt Number COSA# QX 151 A Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Forge Engineering Phone (907) 522-7773 Address PO Box 240773 Anchorage, AK 99524 Engineer's Printed Name Benjamin Schiller P.E. Date 9/26/18 i�P� •,.. .AC.qe- 914 6. DSD SIGNATURE 3 / P System#1 Approved for bedrooms Benja in Schiller System #2 Approved for bedrooms +tslF�FO a ��`��,��,.� Disapproved tl\ ���"o�"� Conditional approval for bedrooms, with the following stipulations: V�QP��N U��VChO ON-SITE 0 WATER AND m•' rock WASTEWATER Q • PROGRAM Air SER\1\65° By: Original Certificate Date: (6 57O The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: `^ COSA Checklist X Nitrate Advisory., . Septic System Advisory Arsenic Ativisbrj/ Well Flow Advisory Other COSA blue sheet_E c • If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: Scenic Heights Lot 4 Parcel ID: 020-291-79 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) Y Date completed 6/5/18 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 426 ft. Cased to 111 ft. Casing height(above ground) 24 in. FROM WELL LOG AT INSPECTION Date of test 6/5/18 NEW Static water level 232 ft. ft. Well production 1 •5 g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform Neg colonies/100 mL Nitrate 2.28 mg/L • Arsenic ND ug/L Date of sample: 9/14/18 Collected by: Forge Engineering B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 5/4/18 Tank size 1000 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping Pumper New Construction C. ABSORPTION FIELD DATA Date installed 5/4/18 Soil rating (g.p.d./ft2 or ft2/bdrm) 0.8 System type Deep Trench Length 36 ft. Width 3.0 ft. Gravel below pipe 8.0 ft. Total depth 11 .9 ft. Eff. absorption area 576 ft2 Monitoring tube Y Depression over field N Date of adequacy test New Results (Pass/Fail) For bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment(past 12 mo.) (Y/N &type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot >100' On adjacent lots >100' Absorption field on lot >100' On adjacent lots X100' Public sewer main '75' Public sewer manhole/cleanout >100' Sewer/septic service line >25 Holding tank >1 00 Animal containment areas >50' Manure/animal excretestorage areas >100' SEPTIC/HOLDING TANK ON LOT TO: Building foundation Property line Absorption field >5 Water main >10' Water service line >10' Surface water >100' Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line 10 Building foundation 10 Water main >10' Water Service line >10 Surface water �1 00 Driveway, parking/vehicle storage Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS G. ENGINEER'S CERTIFICATION ��®�A®'� ��� k I certify that / have determined through field inspections and cAge �®� ^�,q9��i review of Municipal records that the above systems are in Gj).• `oma -y��(A conformance with MOA COSA guidelines in effect on this date. 1 *. 49 TH /\ . * Benjamin Schiller, P.E. Engineer's Printed Name ® 0 Date 10/12/18 0q •.` BenjamiySchiller, iS : ff � 9 • CE 12592 • f Fc�l•• 10/12/18• •••�� ���F-,PROFESS\ON'-O®' COSA brown sheet 10-10-12.doc SCENIC HEIGHTS SUBDIVISION LOT 4 43,628 S.F. GRAVEL DR. LOT 2 GRAVEL DR. LOT 3 175.50' S 89°56'34'E 83.0' I WELL I I LOT 4 c.; I I c•P I I ii,.. I I o co 1? I I I I I I I I I ON I I S r 41t, I I Pn N BN I I N G 1 .1 N N % CC ito L I I • w CD v C 52.3'1 I 30' w in U � „ _ 40' o I I o w I 0 I oocc z • 1 z 1 • FIRE SEPTIC SYSTEM TURNAROUND I I I I I 50' SECTION LINE ESMT. •{ I • 10' T. & E. ESMT. I J-f ` 10' T. & E. ESMT. I • S 89°57'39"E 211.66' 001111111114 b. 0 4OF .♦ • ' - 44 ♦ P .• ......... . LS, . co'ti9 • � : •'V 0 . *: 49TH . * J IN o 111 • Jeffery A. Gostold : o M "' ) jik 9 . LS-6091 : e sk.•.• 8/29/2018 ...0. ..4 • •. o fes5i0nd1\- .• '.�. 0 11 S,,•� l- e ti: 'a, . 4,, f AS — BU I L T I HEREBY CERTIFY THAT I HAVE SURVEYED THE GASTALDI LAND , PROPERTY DEPICTED ABOVE AND THAT NO ,b° ENCROACHMENTS EXIST EXCEPT AS INDICATED. • 000E SURVEYING, LLC IT IS THE RESPONSIBILITY OF THE OWNER TO JEFF A. GASTALDI, R.L.S. DETERMINE THE EXISTENCE OF ANY EASEMENTS, oe�•• no0F��V ^P62000 E. DOwLING RD., SUITE 8 COVENANTS OR RESTRICTIONS WHICH DO NOT ANCHORAGE, ALASKA 99507 APPEAR ON THE RECORDED SUBDIVISION PLAT. PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA GRID DATE HEREON BE USED FOR CONSTRUCTION OR FOR SW3637 8/29/2018 ESTABLISHING BOUNDARY OR FENCE LINES. BUILDING DETAIL ANCHORAGE RECORDING DISTRICT, ALASKA SCALE: 1"=20' F.B. JOB NO. NOTE : NO CORNERS SET THIS DATE 4,