ON-SITE WASTEWATER INSPECTION REPORT
AUG
Permit Number: OSP181067 PID Number: 015-331-06 6 2019
Dwelling: ❑■ Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project:I■❑ New ❑ Upgrade
Name:
Tamara Currier
ABSORPTION FIELD
FW Deep Trench ❑ Shallow Trench EJ Bed E] Mound
Address ;u6) q.5kil d� 6, br} f ftViOrl't e- AK-
❑ Other
Phone
of Bedrooms
Soil Rating
Total depth from original grade
TNumb—er
0.8 GPD/SF
10.0 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
3.0 Ft.
Gravel depth beneath pipe
7.0 Ft.
Subdivision Block Lot
NW4SW4SW4NE4 PTN
Fill added above original grade
-0.6 Ft.
Gravel length
56 Ft.
Township Range Section
12N 3W 23
Gravel width
4.0 Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION
DISTANCES
To!
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
756 Ft
1
Ft.
Well
>100'
>100'
N/A
N/A
>25'
TANK 0 Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Infiltrator Water Technologies
Capacity
11,530 Gal.
Surface Water
>100'
>100'
N/A
N/A
Material
Number of compartments
Lot Line
>5'
>10'
N/A
N/A
Plastic
2
NA
Foundation
>10'
>10'
N/A
N/A
LIFT STATION
Manufacturer
Capacity
Curtain Drain
None
Noted
Gal.
Remarks 2" Insulation Over Absorption Trench.
Pump on level at
in.
Pump off level at
in.
High water alarm at
in.
Pump make and model
Electrical Inspections performed by
PIPE MATERIAL House to tank D3034 Tank to
drainfield D3034
Installer
Whitters Excavating
Drainfield D3034 CO/MT
Inspector J. Miilette
BENCH MARK (Assumed elevation) 100 ft
Inspection1st 5/22/18 5/23/18
Location and description
dates: 2nd
3'd 411
Top of foundation.
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineer's Stamp
OF
Conditional Approval: Date
ffR••°••�•R.l-9+���
a 49th '.
YR.
kyr iARR3Y •RR II•j/R�jYRARRR SRAR1(��,{
�A�
®A <
P' AYARRi/ARAE84RARARER RYRARA....ARAA R ARARRR..AARRAv
MICHAEL> . AD.> Rsory V
No. C£--4387
®
._,�r���'•R,
Approved Date
8/15/19 R.'•����
F RARRRRRRIAARRRR••
mspecuon Kepon:_y-i--iz.aoc
T12N R3W SEC 23 NW4SW4SW4NE4 PTN
PERMIT # OSP181067 PID # 015-331-06
i
\\ WELL
�tADJACENT WELL\\, 1 00'WELL RADII
ujA
LLYFGO
U / MT1 62 . B
Q O / 2CO
0 J
m i
\ ® 1530 -GAL PLASTIC
LGN 4' WIDE, 7' CQ1 TH#2 ; SEPTIC TANK
EFFEC rlVE DEPTH 8(1T2
ABSORPTI DN TRENCH
MU TH#1
Caz
LOT 1B .......
ALTERNATE SITE
..l.l.v5sreens�sts Forgo logo.;pg
+49th '.
MICHAEL E. ANDERSON w e
CE -4381
��crfy°• 8/15/19 ,.o+����
ROADWAY EASEMENT
ROCKRIDGE
DRIVE
PLAN AS -BUILT
0 50 0
A B
FCO
13.6
46.8
SV1
21.5
60.8
SV2
19.6
67.6
MT1
19.6
70.5
2CO
24.4
70.6
C01
48.9
76.3
MT2
48.8
73.7
MT3
93.7
122.9
CO2
98.6
127.6
9
LOT 6
Septic
Area
LEGEND
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEAN(
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
T12N R3W SEC 23 NW4SW4SW4NE4.PTN
PERMIT# OSP1 81067
PI D # 015-331-06
2" INSULATION
01--
75
0
92.6
-1.1'...--.1--.b,,,
85.6
95.0 FINISH GRADE
- 95.6 ORIGINAL GRADE
56'
86.1
3.5
92.6
79.6 NOTE: MONITORING TUBE DISTURBED DURING FINAL GRADING
PROFILE AS -BUILT
(NO SCALE)
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
4700 ELMORE ROAD ANCHORAGE, AK 99519-6650
SOILS LOG AND PERCOLATION TEST
LEGAL DESCRIPTION: T12N R3W SEC23 NW4SW4SW4NE4 PTN
PERFORMED FOR: CURRIER TAMARA
DATE: 4/22/18 PROJECT No.:
PARCEL ID#: 015-331-06 TECHNICIAN: J. MILLETTE
DEPTH TEST HOLE
(feet)
1
2
4
5
6
7
8
9
10
11
12
13
14
15
16 -.BOH
17
81920 18-
19-
20
SLOPE
BROWN CLAY / ORGANICS
SANDY SILTY GRAVEL
GM
WAS GROUND WATER ENCOUNTERED? NO
IF YES n WHAT DEPTH? -
DEPTH OF WATER AFTER MONITORING: NONE
DATE OF MONITORING: 4-3-19
L
P
E
SITE PLAN
SEE SITE PLAN
U
2
DATE
READING
GROSS TIME
(MINUTES)
NET TIME
(MINUTES)
DEPTH To
WATER
(INCHES)
NET DROP
(INCHES)
4/12
TEST HOLE PRESOAKED PRIOR TO TESTING:
1
15:18
4
2
15:48
30
9z
5 8
3
15:49
4
4
16:19
30
92
52
5
16:20
4
6
16:50
30
91
512
PERCOLATION RATE: 5.5 (MIN/INCH) PERC. HOLE DIA. --§—(INCHES)
TEST RUN BETWEEN: 4 FT. and 5 FT.
COMMENTS: TEST HOLE #1 DEEPENED TO PROVE SEPARATION TO IMPERMEABLE SOIL PER PERMIT
REQUIREMENT. WATER MONITORING BASED ON ORIGINAL TEST HOLE.
beveioa'mi mint Services Department
slid€ g Safety Division
r
' -Sate Water & Waste eater Program
„.;.
4700 Elmore Rood
P.Q. Box 196650 Ane orctge, AK 99507 s r c- r r
Mark Begich %'MW'mL-'2L0 a/onsite
Mayor (907) 343-7904
Well Log
Permit Number-.OSPIS1067 Date of Issue: 5/7/18
Date Started: 7/3/18 Date Completed: 7/13/18 Is well located at approved permit location? (x { Yes U No
Legal Description: T12N R3W SEC23 NW4SW45W4NE4 PTN 6:2639
Property Owner Name & Address: Currier Tamara
Borehole Data: Depth (ft)
Soil Type, Thickness & Water Strata From To
stickup
0
2
silt & gravel
2
65
boulder
65
67
silt & gravel V
67
82
wet silt & gravel
82
8s
clay w/ gravel
85
110
silty clay
110
120
wet silty clay
120
165
silty clay w/ H2O
sand w/ gravel & H2O
265
178
178
181
coarse gravel w/ F120
181
186
Water Sample Results: F -t 5't j
Arsenic: 1,L V ug/L
Nitrates: 1203 mg/L
Total Coliform Bacteria: colonies/100ml,
Other Bacteria: Ne col/100ml:,
Method of Drilling U air rotany L{ cable tool
Casing type: steel
Wall Thickness: .250 inches
Diameter: 6 inches Depth: 186 feet
Liner Type
Diameter: inches Depth: feet
Casing stickup above ground: 2 feet
Static water level (from ground level): 84 feet
Pumping level: feet after
hours pumping _ gput
Recovery Rate- 15 gpm
Method of Testing: airlift
Well Intake Opening Type:
Mx Open. End n Open Hole
❑ Screened Start feet Stopped feet
M Perforations Start feet Stopped feet
Grout Type: Bentonite Yolume.granul'
Depth. 20' Start 0 feet Stopped 20 feet
Pump: Intake Depth 152 feet
pump size 3/4 hp Brand Name Grundfos SQE
Well Disinfected Upon Completion? n Yes n No
Method ofDisinfection: chlorine tablets
Comments:
Well Driller: Hefty Drilling, Inc.
3540 Akula Dr.
Anchorage, AIC 99516
Attention: The well driller shall provide a well log to DSD within 30 days of completion.
bevelopnen s' Services Depanr` mizn-f
On -Site Wa-s-er �'_' Was,; e?'Sa er Progif ann
4700 Elmore Road
P.Q. Sox 196050
MarkBegich Anchorage, AK 99507 s a f E T Y
Mayor �^xvvj.muni.oro/onsite
(907) 343-7904
Pump Installation Log
Well Drilling Permit Number: 1;510 6i Date of Issue: _-7 - 1 v
Parcel Identification Number:
Legal Description T Q A/ 02 3 w c)1 Property Owner Name & Address: II
q 0� Mr 6. (—(/ Ir Y, C,r-
C14:7Y� PxA PI;d5e- 01r,
Pump Installation Date: e - C'—_ IC,
Pump Intake Depth Below Top of Well Casing: I'j2 feet
Pump Manufacturer's Name:
Pump Model: l U 5 q E: 07 UO
Pump Size 7/y hp
Pitless Adapter Burial Depth: 1 ,� feet
Pitless Adapter Manufacturer's Name: 6-1 C)
Pitless Adapter Installer: Dec) N!,
Well Disinfected Upon Completion?Yes n No
Method of Disinfection:
Comments:
Pump Installer Name:
/it ftyD6l4,nnc
�c, A7C99511
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
V
x
m
Z
0
m
D
X
11
,' rg
30'
30'
i
I3O8.54'(MEAS)
-------
--------
NORTH 3O9.16'(REC 78-195) --------
25'
------
--------
N 00000'00"E 343.54' --------
BASIS OF BEARING
{V
C
\
O
® \0
J
(n
m 79.8'
;uN
CD
x D
64.7'
A
U
cn
o
j�7
0D
*
NITIZall
m
r
U)
m
z
Iia
0
o
GRAVEL DRIVE
------
/
--------344.61'(MEAS)--------
57.26-----------
m •
N 00006'25"W 319.61'(MEAS)
0
v m
- ------ N 00006'51 "W 317.5O'(REC) --------
_
o
-<
N
�
mN
rn
25'
25'o
0
V
x
m
Z
0
m
D
X
11
,' rg
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE:
PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
TECHNICIAN:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
DEPTH
(feet)
PROJECT No.:
TEST HOLE 1
SLOPE
SLOPE
SITE PLAN
See Site Plan
DATE READING GROSS TIME(minutes)NET TIME(minutes)
DEPTH toWATER NET DROP
TEST HOLE PRESOAKED PRIOR TO TESTING:
PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH)
TEST RUN BETWEEN: FT. and FT.
COMMENTS:
(inches)(inches)
T12N R3W SEC23 NW4SW4SW4NE4 PTN
4/22/18
J. Millette
Development Services Department
4700 Elmore Road Anchorage, AK 99519-6650
Municipality of Anchorage
DATE OF MONITORING:
WAS GROUND WATER ENCOUNTERED?
DEPTH OF WATER AFTER MONITORING:
IF YES @ WHAT DEPTH?
NO
-
None
5.5 6
4 5
015-331-06
CURRIER, TAMARA
Professional Engineers Stamp:
15:18
4/12
1
2
3
4
5
6
30
30
30
4
9 7
8 5 7
8
4
9 1
2 5 1
2
4
9 1
2 5 1
2
15:48
15:49
16:19
16:20
16:50
1' OB
SANDY SILTY GRAVEL
4-3-19
BROWN CLAY / ORGANICS
BOH
GM
TEST HOLE #1 DEEPENED TO PROVE SEPARATION TO IMPERMEABLE SOIL PER PERMIT
REQUIREMENT.
Apr 15, 2019
., ,""""r'0, MUNICIPALITY OF ANCHORAGE , en(
On-Site Water&Wastewater Program �,, .. S
b �{ r fir, PO Box 196650 4700 Elmore Road ..
il 7 Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997
7's http://www.muni.orglonsite '
lliti
__ I)t•paitntt•nt
4k0.P GF'
On-Site Water & Wastewater System Permit
Permit Number: OSP181067 Effective Date: 5/7/2018
Work Type: WellSeptic Initial Expiration Date: 5/7/2019
Tax Code Number: 01533106000
Site Legal Address: T12N R3W SEC 23 NW4SW4SW4NE4 PTN G:2639
Site Mailing Address: 6645 ROCKRIDGE DR, Anchorage
Owner: CURRIER TAMARA Lot Size in Sq Ft: 82840
Design Engineer: FORGE ENGINEERING Total Bedrooms: 4
This permit is for the construction of:
0 Disposal Field 2 Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions: A test hole within 30 feet of the drainfield shall be dug/deepened to 16 feet prior to
construction of the drainfield to confirm 6 feet separation to impermeable. If the results require a design change,
construction of the system shall stop pending On-site review and approval. Please submit stamped and signed
results with the inspection report.
Received By: I,' ility,,, 77) ` ! Date:
Issued By: � j�,C(�(, Eit)t€ J Date: 5 e
MUNICIPALITY OF ANCHORAGE
1. -�.
Community Development Department s 56 8 9 10 7 " one: 907-343-7904
Development Services Division 'pax: 907-343-7997
On-Site Water& Wastewater Program ti
ON-SITE SEWER/WELL PER AokiaA'T'ION
ti
6 c�,
Parcel I.D. 015-331-06 c> c>�
Tamara Currier 01 s 8
Property owner(s) lay phone
Mailing address 6412A Whispering Loop Anchorage, AK 99504
Site address NHN Rockridge Drive Anchorage, AK 99516
Legal description (Sub'd., Block & Lot)
Legal description (Township, Range & Section) T12N R3W SEC 23 NW4SW4SW4NE4 PTN
Lot Size 82,840 Sq. Ft. Number of Bedrooms Four (4)
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(®all that apply)
Absorption Field ❑X Initial 0 Single Family (SF) n
(w/wo ADU)
Septic Tank ❑X Upgrade n Duplex (D) [
Holding Tank [ Renewal
Multiple Dwellings ]
Privy ❑ (SF and/or D)
Private Well ❑X
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 4 wq - Waiver Fees:
Date of Payment: (-1/,6/1g Date of Payment:
Receipt Number: (� �QD Receipt Number:
Permit No. OSP1911)(o7 Waiver No.
Permit App_ -: ::.,c
.rte
GE
ENGINEERING
PO BOX 240773
ANCHORAGE,AK 99524
522-7773 677-7766(FAX)
April 29, 2018
Municipality of Anchorage
Development Services Dept- On-Site Water& Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: T12N R3W SEC 23 NW4SW4SW4NE4 PTN—Rockridge Drive
Septic system design and permit application
Dear On-Site Services Engineer:
The owner of the above lot intends to build a 4-bedroom home on the property, so we are
submitting this permit application for the construction of a new well and septic system. The
attached site plan identifies the location of the home as well as the proposed well. septic location
and alternate site. No conflicts exist between this proposed system and any other well or septic
system,whether on this lot or adjacent lots.
The ground surface on the lot slopes toward southwest at slopes less than 25%. It is in that
flatter area that the new septic system is located. There are no slopes greater than 25% within 50
feet downslope of either the primary or alternate site. Ground surface contours are shown on the
site plan showing the grade and direction of flow. Stormwater drainage will not impact this
septic system.
The new trench will be constructed parallel to the slope as much as possible. It will be a
minimum of 100' from all wells and surface water, and more than 5' away from the septic tank.
The alternate site is located more than 14' away.
Please refer to the attached test hole logs and plan and profile pages for the septic design. If this
design is followed,there will be no adverse impacts to adjacent properties.
Sincerely,
14,1„1
Michael E. Anderson, P.E. •
10-4-AL,afeett42,04,-.)
• ,MICHAEL E. ANDERSON1
•
Attachments ti ip No. CE-4381 ti •
X44, E== w�
T12N R3W SEC23 - NHN ROCKRIDGE DR
Existing Well I I Proposed Well
1 LOTS
l
\
/ .:
\ /
. . .
- �
i / 07
_ — 4-BDRM HOME N .. �_
LL N \ FCO . .. = (,)
O Y 1,250 Gallon— • — ' w Y
Q UO e Septic Tank
40'SV
, O
CO CO TFak2 .• . CO
0Y•
C•-�� - Q
• eT"ai :54'Long x 3'Wide x 7'Effective -
Depth Absorption Trench
lemnate SiteLOTE
f .
LOT6
vE
1
- 0GE�R Septic
ROGKR Area
ROADWAY EASEMENT
ROCKRIDGE DRIVE
NOTE:
�•E NO SLOPES>25%WITHIN 50'OR SURFACE WATER WITHIN 100'OF THE LEGEND
„-,,-. •.• 7 PROPOSED SEPTIC SYSTEM
ar C-).•• '�.. .. CO-CLEANOUT
•4` 49th• /' ••••*• ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS 2C0 DOUBLE CLEANOUT
• 2• %4' PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC FCO FOUNDATION CLEANOUT
I FS-FLOW SPLITTER VALVE
'' ..._..�..`��� " SYSTEMS. MH-MANHOLE
O•c`MI�EL E. ANDERSON` . 0 50 100
••-' '••. No. cE-4381 -.- i o
••�� ., ,�^ V: = FEET
SLOPES>25/o MT-MONITORING TUBE
• 2Y le `:•• _SLOPES>46% SV-SEPTIC VENT
••44•, =w'at, 1"=50' TH-TEST HOLE
T12N R3W SECTION 23
NW4SW4SW4NE4 PTN
DESIGN FACTORS: SYSTEM REQUIREMENTS:
600 GPD PEAK FLOW 3'WIDE DEEP TRENCH SYSTEM
PERK RATE: 5.5 MIN/IN 1,250-GAL SEPTIC TANK
APPLICATION RATE: 0.8 GPD/SF
600 GPD/0.8 GPD/SF/ 7' DEEP/2 SIDES = 53.6 LF TRENCH REQUIRED (54 LF SPECIFIED)
BOTTOM OF TRENCH: 10' BELOW GRADE
FLOW LINE ELEVATION: 3' BELOW GRADE
TOP OF TRENCH: 0.5'ABOVE GRADE
t 6"
—
'll�l� l -Ilf-
-I I f-I I I�i f=Ilk=1 I o
III-1 11-I I H I I-I i i
HI I I-1 I I-1 I fff 11
2'-6" 111-111-111-11-111
k 1Ik=1I 1I1=1I�II�1
ILEI -IIHIHIHI=
H�11l 111=1 I�I I I-1
11=-11E1111=1111111--_-_-111111
=�'�'=•'=•'=•'=•' =•'=•' 4" PERFORATED PVC (HOLES DOWN)
=0'•"•:•"•"••• DRAINFIELD ROCK
7'
'•;•:•:•:•:•:•:•:•;•::;::.:.:..
;�,�9;•_•_;�,�,�,�9;;;;;111:;;;
3
TYPICAL DEEP TRENCH SECTION �.• �E of
(NO SCALE) � `�9 t
NOTES: 49,th '}�,
1. GRADE AREA OVER TRENCH TO DRAIN AWAY G,...... ..... ',•••••,
•
e --- i
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' �• •MXcI � E. nn rts� :��
WITH 2" OF INSULATION •yrs'., ►�O=4�a1
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER -Lr Lt • Fes,
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY ����� =I 4 ''
MUNICIPALITY OF ANCHORAGE �e\>:•• ......
.
DEVELOPMENT SERVICES DEPARTMENT '; !— •: •• •
4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 Ct /\ . .a....i
SOILS LOG AND PERCOLATION TEST '>,vAtti E. ANDERSON:=
(1� No . CE-4381 list
Sj —LQ-i6j••`• ��
LEGAL DESCRIPTION: T I2N R3W SEC23 NW4SW4SW4NE4 PTN 4 ••. L -.•'
PERFORMED FOR: CURRIER, TAMARA .��L11� . .-
DATE: 4/12/18 PROJECT No.: Professional Engineers Stamp:
PARCEL ID#: 015-331-06 TECHNICIAN: J. MILLETTE
DEPTH TEST HOLE 1
(feet)
1 1'OB SLOPE SITE PLAN
BROWN CLAY/ORGANICS
cr ,.
3
:.I' •.
=:f
4 •.yr
5 ;q._y,,: SEE SITE PLAN
6 -r �`•: :f,: 1
7 '%. •.-*/;• - SANDY SILTY GRAVEL
:1:?..::: GM
10 ::-...%:!-:,:.:;::-.;1 •' • WAS GROUND WATER ENCOUNTERED? NO
'i sitr»r.,
'' ";‘^' IF YES WHAT DEPTH?
11 `� _.
:• :•:r DEPTH OF WATER AFTER MONITORING: NONE
-.;,.;-:.'•;' DATE OF MONITORING: 4-29-18
• . .
12 .: .. �
•
`=`=::`.:`':" GROSS TIME NET TIME DEPTH TO NET DROP
DATE READING WATER
13 % y;":;.. •..-;:,-;1:r;;:..
, :;. ti (MINUTES) (MINUTES) (INCHES)
..—�: (INCHES)
14 71f,':`k.' 4/12 TEST HOLE PRESOAKED PRIOR TO TESTING:
15 BOH 1 15:18 4
16 2 15:48 30 98 58
17 3 15:49 4
4 16:19 309152
18 5 16:20 4
19 6 16:50 30 92 52
20
PERCOLATION RATE: 5.5 (MIN/INCH) PERC.HOLE DR. 6 (INCHES)
TEST RUN BETWEEN: 4 FT. and 5 FT.
COMMENTS:
F.
MUNICIPALITY OF ANCHORAGE ��\•
P,.••"' " " '•;YS
DEVELOPMENT SERVICES DEPARTMENT -S 49th i\ A-
A1
4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 ! I�� ,.
SOILS LOG AND PERCOLATION TEST 0-, MI�t nNnE^rzs`aN —;�z
X11No. CE-4381 '.�
LEGAL DESCRIPTION: T I2N R3W SEC23 NW4SW4SW4NE4 PTN *•1;;p% ii ":'
PERFORMED FOR: CURRIER. TAMARA It"""sem
Professional Engineers Stamp:
DATE: 4/12/18 PROJECT No.:
PARCEL ID#: 015-33I-06 TECHNICIAN: J. MILLETTE
DEPTH TEST HOLE 2
(feet)
1 1'OB SLOPE SITE PLAN
2 .17;1j.,;s;' .
5 SEE SITE PLAN tz
� 'j
6 a
7 r-':=:::`''''' SANDY SILTY GRAVEL
:1,:i•-::4.4*., GM
8 ?, .;;-'..c.-.;:-:.::.
.
10 •:-',..ii:::?.?-';:s;'.. . WAS GROUND WATER ENCOUNTERED? NO
.!::" :i;;;
IF YES Q WHAT DEPTH?
DEPTH OF WATER AFTER MONITORING: NONE
�'`•�'i'�4 DATE OF MONITORING: 4-29-18
12 ;;•';..;:
:':-.1:S. .,;:. DEPTH To
'-.1-:.::,.1.:::•‘.•;4'.,-•! DATE READING GROSS TIME NET TIME WATER NET DROP
` = (MINUTES) (MINUTES) (INCHES)
13 •: I:•-t:::;% (INCHES)
14 .•:"':''T '• ' 4/12 TEST HOLE PRESOAKED PRIOR TO TESTING:
15 BOH?.;-:!
OH' . 1 15:26 5 2
2 15:56 30 7a 1 s
16
3 15:57 5 1
17 4 16:27 30 78 18
18 5 16:28 5 i
19 6 16:58 30 7$ 1 e
20
PERCOLATION RATE:18.4 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN: 3 FT. and 4 FT.
COMMENTS:
JNociPALirr p�
Municipality of Anchorage ,went s,
On-Site Water and Wastewater Program ___________
P.O. Box 196550 4700 Elmore Road
j Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax: (907)343-7997
http:/lwww.muni.org/onsite
4hCHOF ot i.)cpai tinent
Review Comments
Engineer: FORGE ENGINEERING 5/2/2018
Legal Description: T12N R3W SEC 23 NW4SW4SW4NE4 PTN
Parcel ID: 01533106000
Permit: OSP181067 WellSeptic
Report Type: On-Site Review Completed By: R.Carroll
The application has been reviewed and the following comments have been generated. These are to be satisfactorily
addressed prior to MOA approval:
1. Submit plot plan (AMC 15.65.050D.1).
2. Test holes are not deep enough to demonstrate separation to impermeables or ground water(taking seasonal
adjustment of 1 foot into account). Please address.
1. The plot plan is attached.
2. Recent observations indicate the test hole remain dry as of May 6 or slightly more than 1 week from II
accepted date for high groundwater observations. We are confident the test holes will remain dry througl
that period and will provide documentation to demonstrate our conclusions. The test holes will also be
excavated to a depth of 16' prior to construction to verify the lack of an impermeable layer. The results o
the test hole excavation will be submitted for your review. We request a special condition be added to th
permit requiring the test holes be extended to a minimum depth of 16' prior to construction.
T12N, R3W, SECTION 23
NW1/4 SW1/4 SW1/4 NE1/4 PIN
PARCEL ID, 015-331-06-000
CONTAINING 82,840 S.F., MORE OR LESS
745'J765'
N 89"3B'30"E 240.43'(MEAS) 0.
76.0'
0
b '0 0R1
of OSP.
*0.5
7o
A
9
iia* < f 'A
a
1"" VIIIIIIIIIIIIN ,F
pROA / x
�fO 9UILOING / C.
M¢pp
VI k 6 b N
O
I llifili
co Y nn
6W ,r v ;�"
vv "' " W ', Nal
vio w
O O
Or::; S p J
p SS
'o'�M 8� q 2Z
4 gg
O Z
Z
1 "=40'
R=165.00•
- -
750'
,-410- -
1+�''�0 20 ORS
cCCCR10GE ��i
n
- ' w
—12.78ROADWAY EASEMENT
(BK 936. PG 0223)
N
ROCKRIOGE DR.
N 89'53'52"E 241.07'(MEAS)-SEE NOTE
nb 737' ., (PUTTED RIGHT OF WAY) 775' •:n
N ROCKRIDGE DRIVE cm
,1
*Assam.,
q•• OF 10� , (4•
• j
•• • '*; 49TH *) �
'.o
•
•
•
. Jel ,Io�tl. f
o•... yis 6988 ,`. I 7�_
a•''' •1•�••'otic• J 52.0.4
4. o'ess:0nos'- 44 NOTE: BOUNDARY DIMENSIONS PER WILLLV.M FLEMING m. " 6v47 0 4'cyl. `
f•\SUS.* SURVEY DATED 10/7/99. >.D. ?70.
'
'L OT PL AN I HEREBY CERTIFY THAT I HAVE SURVEYED
THE PROPERTY DEPICTED ABOVE AND THAT s I'V.'T '
GASTALDI LAND THE PROPOSED IMPROVEMENTS AND DRAINAGE
SURVEYING. LLCPATTERNS ARE AS SHOWN HEREON. IT IS THE `' ,'JEFF A. GASTALDI, R.L.S. RESPONSI8ILITY OF THE OWNER, PRIOR TO 60.25.
WO E. DOwuNG RD..sua 8
INCHORAGE,ALASKA 99507 CONSTRUCTION, TO VERIFY THE PROPOSED
PHONE 248-5454 BUILDING LOCATION ON LOT, BUILDING
RIO DATE DIMENSIONS GRADE AND UTILITY CONNECTIONS DEC, .. •'
SW2639 4/5/2018 AND TO DETERMINE THE EXISTENCE OF ANY *70.
EASEMENTS.COVENANTS. OR RESTRICTIONS
B. JOS NO. WHICH DO NOT APPEAR ON THE RECORDED
SEC23PP SUBOMSION PUT. BUILDING DETAIL
SCALE: 1••m20'
MUNICIPALITY OF ANCHORAGE
#;M
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 015-331-06-000
Expiration Date:
Legal description T12N R3W SEC 23 NW4SW4SW4NE4 PTN
Site address 6645 ROCKRIDGE DR Anchorage AK 99516
9/19/2023
Current property owner(s) LUGO FRANKLIN &CURRIER-LUGO TAMARA
X The On-site system(s) is/are approved for 4 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or advisories:
Original Certificate Date: 6/19/2023
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
COSA ApprovaLJune 2022
MUNICIPALITY OF ANCHORAGE
0 t'
Development Services Department Phone: 907-34377904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 015-331-06
Complete legal description T12N R3W SEC 23 NW4SW4SW4NE4 PTN
Location (site address) 6645 Rockridge Drive Anchorage Alaska 99516
Current property owner(s) FRANKLIN LUGO & TAMARA CURRIER-LUGO Day phone
2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS
3. TYPE OF WATER SUPPLY: ® Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units ❑ Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ❑ Steel ® Plastic ❑ Concrete ❑ Fiberglass
Age 5 - See advisory if steel older than 20 years
6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ® Deep Trench ❑ Wide Trench ❑ Seepage Pit
Waiver request for:
Expedited review requested: ❑
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $ 5— �-o Waiver Fee $
Date of Payment I qI 2-02 3 Date of Payment
COSA # 0 S C- 2.3 ' 1 '� S Waiver #
COSA Application.doc
COSA Checklist.docx
COSA Checklist
Legal Description: T12N R3W SEC 23 NW4SW4SW4NE4 PTN Parcel ID: 015-331-06
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled 7/13/18 Total depth 186 ft
Cased to 186 ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) 18+ in.
Date of flow test for COSA 6/1/23
Static water level at beginning of test 76 ft.
Well production at time of test 4.5+ gpm
Water storage tank volume NA gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate 0.876 mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by Date 6/1/23
Comments __________________________________________________________________________________
B. TANK DATA
Measured operating fluid level in septic tank 44”
Date of pumping 6/1/23
Required maintenance completed, if AWWTS
Comments: 1530 GALLON INFILTRATOR TANK
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D. ABSORPTION FIELD DATA
Which system tested (date installed) 12/5/19
ALL standpipes present per record drawing
Total measured depth from grade 11.5 ft (max)
Measured depth to pipe invert from grade 2.8 ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes (MT) go to bottom of effective. (ED)
If not, state depth into effective
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months) N
If yes, enter date
Adequacy test date 6/1/23
Results Pass
Fluid depth prior to test 10 in
Water added 750 gal
New fluid depth 26 in
Elapsed time 1440 min
Final fluid depth 10 in
Absorption rate 600 gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) 84 in (MOA 7’ ED)
Effective depth used 10 in (Final Fluid Depth)
Effective depth (ED) remaining 74 in
Comments/Deficiencies: Approximate total measured depths from existing grade. Effective Depth (ED) per elevation
measured shots & ED appears approximate. No known freezing issues.
COSA Checklist.docx
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot)
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Engineer’s Printed Name CURTIS HUFFMAN, PE Date 6/10/23
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting &