Loading...
HomeMy WebLinkAboutGROVER PLACE LT 3Onsite File Municipality of Anchorage Community Development Department Page 1 of 2 �iJ'rU4Jti u � a MrNli 71 m neri � Municipality of Anchorage Community Development Department Page 1 of 2 On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181068 PID Number: 015-081-45 New ❑ E] Upgrade Name: WHITE RAVEN DEVELOPMENT ABSORPTION FIELD Dee ❑ p Trench El Shallow Trench EJ Bed El Mound Address E 99TH AVENUE ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 5 0.8 GPD/SF 10.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4.0 Ft. Gravel depth beneath pipe 6.0 Ft. Subdivision Block Lot GROVER PLACE 3 Fill added above original grade 0 Ft. Gravel length 45/45 Ft. Township Range Section Gravel width 2.5 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 1,080 z Ft 2 14.5 Ft. Well 116.1 133.7 N/A N/A 85.3 TANK El Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer ANCHORAGE TANK Capacity 1500Gai. Surface Water 100+ 100+ N/A N/A Material Number of compartments Lot Line 65.5 39.8 N/A N/A STEEL 2 NA Foundation 34.8 56.2 N/A N/A LIFT STATION Manufacturer Capacit Curtain Drain 50+ 50+ N/A N/A Gal. Remarks Pump on level at in. Pum evel at in. High water alarm at in. Pump m k6 -and model Electrical Inspections performed by Installer PIPE MATERIAL House to tank 3034 Tank l0 drainfield 3034 BRAIN HARTEN / WHITE RAVEN Drainfield 3034 CO/MT 3034 Inspector PANNONE ENGINEERING SERVICES BENCH MARK (Assumed elevation) 98.Oft InspectionLocation dates: 7/14/18 2'd 7/16/18 and description 3m 7/16/18 4`h 10/25/18 NW BOTTOM HOUSE TRIM COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp OF A�,���� Conditional Approval: Date .: Steven F. I�annotae* Approved Date 1 a 1$ 1 A\ - _ inspection Repon_i-i--i2.coc V V DES!GN GN PARAMETERS _90l PRIMARY/RESERVE SEPTIC SYSTEM NO. BEDROOM: 5 (750 gpd) TH-1 TANK SIZE: 1,500g (MICHAEL E ANDERSON) PERC RATE: 12 MPI SOIL RATING: 0.8 GPD/SF AREA RQD: 937.5 SF SYS. TYPE: DEEP TRENCH - 6.0'ED -MIN LENGTH: 78.1 LF USED: 12.0' THi - LI(2EA) 45 LFx2.5'Wx6.0' E.D., 10.0' TD_ I TOTAL AREA: 1,080 SF m 4 14.5 M-2Mr %N OUT LOT 2 F I JT F '41 ----1 7 A 5BR HOUSE - EL 6? TH-5 92 �(MICHAEL E ANDERSON) 94 j 1 96- !� INSTALLED.. DRAIN FlFLD (2EA) 45LF x 2,5'W x 6.0'ED x 1 O.O'TD INSTALLED CLEAN OUT AND MONITOR TUBE AT EACH END INSTALLED 1500, SEPTIC TANK WITH FOUNDATION CLEANOUT AND DOUBLE CLEAN OUT AFTER .100- ,77 AFTER 104 1.06 08 WELL z 0 0 - 0 0 0z z z Wow Z < -j-f :3 < w Li co 0- 1 < 0 W 0 0 0 0 FILTER FABRIC Z FG. Do. FG, 95-0 n 0 DRAIN ROCK 6" ABOVE PIPE INV TRENCH 1-93.5 _H - DRAIN PIPE flr4' 0 DRAIN PIPE TRENCH 2-93.0 PES 1500 g SEPTIC CONNECT � TO 11111CILE GM TANK 1�10F EACH 6 sm/ 7 FIELD Tl- 6.0' DRAIN ROCK -11.0 a T2:89.0 T2.. �. DRY: cl 7/17/18 PROFILE s I DATE PERF( 10JUL2018 NOTES: PANNONE ENG SVC, LLC Dote '[RECORD DRAWING _ OF A-Cqkk� 10/26/2018 P.O. BOX 100217 ANCHORAGE, AK 99510 ,q PHONE (907) 272-8218 FAX (907) 272-8211 _Scale AQ 1"=50' . ...... ... ... rd LD. NO G ER PACE, LOT 3 !, .......... OVE IV, WHITERRAVENLDEVELOPMENT Steven R: PERMIT -01'5-081-45 NO. E 99TH AVENUE CE 8149 OSP181068 _sheet PLAN ANCHORAGE, AK 0 ss'k 2 OF 3 A B FC 12.1 38.2 Tl 39.6 50.0 T2 49.5 56.1 DCO 52.8 58.2 Cl 66.8 56.5 mi 66.7 58.3 C2 63.7 85.3 M2 62.8 81.5 C3 82.2 71.8 M3 81.4 74,7 C4 80-2 96.9 M4 78.5 92.6 F '41 ----1 7 A 5BR HOUSE - EL 6? TH-5 92 �(MICHAEL E ANDERSON) 94 j 1 96- !� INSTALLED.. DRAIN FlFLD (2EA) 45LF x 2,5'W x 6.0'ED x 1 O.O'TD INSTALLED CLEAN OUT AND MONITOR TUBE AT EACH END INSTALLED 1500, SEPTIC TANK WITH FOUNDATION CLEANOUT AND DOUBLE CLEAN OUT AFTER .100- ,77 AFTER 104 1.06 08 WELL z 0 0 - 0 0 0z z z Wow Z < -j-f :3 < w Li co 0- 1 < 0 W 0 0 0 0 FILTER FABRIC Z FG. Do. FG, 95-0 n 0 DRAIN ROCK 6" ABOVE PIPE INV TRENCH 1-93.5 _H - DRAIN PIPE flr4' 0 DRAIN PIPE TRENCH 2-93.0 PES 1500 g SEPTIC CONNECT � TO 11111CILE GM TANK 1�10F EACH 6 sm/ 7 FIELD Tl- 6.0' DRAIN ROCK -11.0 a T2:89.0 T2.. �. DRY: cl 7/17/18 PROFILE s I DATE PERF( 10JUL2018 NOTES: PANNONE ENG SVC, LLC Dote '[RECORD DRAWING _ OF A-Cqkk� 10/26/2018 P.O. BOX 100217 ANCHORAGE, AK 99510 ,q PHONE (907) 272-8218 FAX (907) 272-8211 _Scale AQ 1"=50' . ...... ... ... rd LD. NO G ER PACE, LOT 3 !, .......... OVE IV, WHITERRAVENLDEVELOPMENT Steven R: PERMIT -01'5-081-45 NO. E 99TH AVENUE CE 8149 OSP181068 _sheet PLAN ANCHORAGE, AK 0 ss'k 2 OF 3 TEST HOLE 1 OR ORGANICS Sm 2 3 4 GM/ SILTY GRAVEL 5 Sm AND SAND 6 7 8 9 10 11 12 13 14 15 16 BON DATE PERFORMED: 07/10/18 SOILS LOG - PERCOLATION TEST SLOPE 9.9 (MICHAEL E ANDERSON) -i (M 94. it/� . ,�.�,,.���--,,_�-r 98 WAS GROUND WATER ENCOUNTERED? N IF YES, AT WHAT DEPTH? DEPTH TO WATER AFTER MONITORING? -DRY DATE: 07/17/18 SLOPE TH X COMMENTS: CONFIRMATION TEST HOLE TO ENSURE SOIL PROFILE WITHIN PARAMETERS OF EXISTING TESTHOLES WITHIN THE SUBDIVISION. SOIL TYPE AND STRATA IS SIMILAR TO OTHER TEST HOLES NOTES: PA24NONEP.O. ENG SVC, LLC Dote — RECORD DRAWING — OF A�,qk�k BOX 102954 ANCHORAGE, AK 99510 10/26/2018 PHONE (907) 272-8218 FAX (907) 272-8211 v Scale 1"=50' ...... . ...... �P-.I.D. NO GROVER PLACE, LOT 3 015-081-45 WHITE RAVEN DEVELOPMENT teven R. 'Pannone w PERMIT No. E E 99TH AVENUE 8149 OSP181068 SOILS LOG ANCHORAGE, AK 3 OF 3 OWNER OFLAND: Hultquist Homes ADDRESS: Bore Hole Data Depth From To LEGAL DESCRIPTION Grover Place Lot 3 DATE: 9-20'18 psnMITmumacn: Oopzozoso DATE npISSUE: 5-29'I8 TAX IDENTIFICATION NUMBER 01508145000 ------- is well located atapproved permit location: iXJYes| |Nu Method ofDrilling: 771airrotary F—lcab|etoo| Depth ofWell: 124' Casing Type: Steel Wall thickness .250 inches Diameter: 6 inches' depth 124 feet Liner type Static Water Level: 57 feet Recovery Rate 25 [\7 9pm | | gph Method ofTesting Ai, Well Intake Opening Type: iXJopen end | |openho|e F—| Screened Start feet Stopped F� --' ---' �� Pe��ration� Start feet Stopped Grout Type: Bentonite Volume: 501bs Depth: from l feet, to 42 feet Well Disinfected Upon Completion: [X]yes Ono no Method ofDisinfection: Chlorine 5OPPM Comments: 4 18 18 41 41 72 95 110 110 118 118 124 Casing Stickup Overburden Silty Sand &Gravel Silt & Sand w/Some Gravel Silty Sand &Gravel Wet Silt Sand & Gravel Clay Silt Sand & Gravel Water Clay &Gravel Sand&Grave| Water Drillers Name: Cole Sullivan ATTENTION: Itbthe responsibility of the property owner msubmit acopy ofthe well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/o, Department of Environmental Conservation. Well Drilling Permit Number: SW OSPI81068 Date of Issue 5-29-18 Parcel Identification Number: 01508145000 Legal Description Grover Place Lot 3 Pump Installation Date: 10'2-18 Pump Intake Depth Below Top ofWell Casing: Pump manufacturer's Name: F&\0 Pump Model: 4F11PO5301S Pump Size: 1/2 Pit|essAdapter Burial Depth: 10 PidessAdapter Installer: White Raven Disinfected Upon Completion? M yes Method ofDisinfection: Chlorine 5OPPM Comments: Pitless Manufacturer: Martinson UPump Installers Name: Sullivan Water Wells Property Owner Name &Address Hultquist Homes hp feet Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. r- 0 to 0 - co I 0 - CD to cr E .0 X 0 r- 0 ti W C D < _0 NOO'03'26"W 300.23' 30' co CT ' 3 to o ul O__) 0- OD cr 00 0 e� 0-®R rTi tIS -01 1000 -00 M Z'� 9 10) TA LO CY co 'q' 30 co 30' tD NOO'03'26"W 300,12' n r ii0 0 n to 41 0 CL i S,l -,, B Q0 r- 0 to 0 - co I 0 - CD to cr E .0 X 0 r- 0 ti W C D < _0 NOO'03'26"W 300.23' 30' to ul O__) 0- r- 0 to 0 - co I 0 - CD to cr E .0 X 0 r- 0 ti I NOO'03'26"W 300.23' 30' OD 0-®R rTi tIS -01 M Z'� 9 10) LO co 'q' 30 co 30' NOO'03'26"W 300,12' S,l -,, B Q0 ol o C�D x I MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP181068 Work Type: WellSeptic Initial Tax Code Number: 01508145000 Site Legal Address: GROVER PLACE LT 3 G:2439 Site Mailing Address: Owner: HULTQUIST HOMES INC Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: aI- tIIIellt 5/29/2018 5/29/2019 46528 2 Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing `7 11 I 1 Cc7 e � o cJ c (A e- � J 5 . ktn s�Q c �\'c r\ rec' 'C Received By: � f"o Issued By: Date: Date: 5 �� 5 7r!,,,, L UMCPAUTY OF J17NCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 015-081-45 Property owner(s) Hultquist Homes Inc. Day phone _ Mailing address 12570 Old Seward Highway, Ste 204, Anchorage, AK 99515 Site address NHN E. 99th Avenue Legal description (Sub'd., Block & Lot) Grover Place, Lot 3 Legal description (Township, Range & Section) Lot Size 46,528 Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial n Single Family (SF) ❑X Septic Tank ❑X Upgrade ❑ (wlwo ADU) Holding Tank ❑ Renewal ❑ Duplex (D) El Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. nature of property owner or authorized agent) Permit/Rush Fees: ag . — Waiver Fees: Date of Payment: q IB Date of Payment: Receipt Number:��JJ�IC-� Receipt Number: Permit No. 6SPI�2 1d)(�;B Waiver No. Permit App__• : ._..:c; Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181068, Rebecca Carroll, 05/29/18 FIELD CP) D x 1 .O'TD \ 1 JNITO TUBE `N 25' NON DISTURB EASEMENT I —90 TH-1 / (MICHAEL E ANDERSON) PRIMARY / RESERVE DRAINFIELD (P) Z / (NSTALLSLF CLEAN OUT AND MONITOR TOUBE l AT EACH END TH-5 �J 12.0 (MICHAEL E ANDERSON) --' TH-2 12.0 92 _ (PES) / 12.0 r FLOW SPLITTER (P)1500g SEPTIC TANK (P) f WITH FOUNDATION CLEAN OUT I / 4 \ AND DOUBLE CLEAN OUT / _OT 2/--�_� 3 96- 9 8 58R .100— HOUSE 100—HOUSE -77 77 (P) ¢� / .102 w _ — Z 04()106ELL P / 108 7WELL (P) J / 10' T&E EASEME T DESIGN PARAMETERS PRIMARY/RESERVE SEPTIC SYSTEM EAST 99TH AVENUE NO. BEDROOM: 5 (750 gpd) TANK SIZE: 1,500g PERC RATE: 12 MPI / ,SOIL RATING: AREA RQD 9375 SPD/SF ��0._LEGEND ��( ABBREVIATIONS -SYS. TYPE: DEEP TRENCH - 6.O'ED WATER LINE/ TH TEST HOLE MIN LENGTH: 78.1 LF WELL RADIUS (P) PROPOSED USE: (E) EXISTING (2EA) 45 LFx2.5'Wx6.0' E.D., 10.0' TD SS NEW SEPTIC CO CLEAN OUT NO. TOTAL AREA: 1,080 SF MT MONITOR TUBE NO. TYP TYPICAL NOTES:���� FOR CONSTRUCTION PANNONE ENG SVC, LLC D QF /��\\�, 4a27/2018 �•.. P.O. BOX 100217 ANCHORAGE, AK 99510 �,�Q� • �s� (, PHONE (907) 272-8218 FAX (907) 272-8211 /Oj •' y + Scale *: * II 1"=50' .... ... ..... P.I.D. NO GROVER PLACE, LOT 3=081-45 WHITE RAVEN DEVELOPMENT / Steven f2. Pannone PERMIT N0. �F CE 8149 c�/� OSP181068 E 99TH AVENUE 0s REV:07/10/1..•�hr PLAN ANCHORAGE, AK ,t1ll�PR0 SSI`AN SheetOF 2 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181068, Rebecca Carroll, 05/29/18 11,1 lc-� 33 DFVFL (POWN r Mimms DwAim wim AM) 11RAWSW QYTK� /-\K SOILLS f._0G - PERCMATIONTEST LU;GAL DESCRIPTION: Lot 4, Grover Subdivision PERFORMED FOR: ----tl!OltlltYL!Icmlies DATE: __ 10/ 1 /20l5___________ PROJECT No.: TECHNICIAN, W.Roberts 6'.. _.. 7 Silty Gravel (� Nm 49th .. NO. MUNI off— Q i E s*i it Z` 0 - WAS M RAI) U A 1 ER 1AMA I MU1 _ No ' AF � Ht Mt �N! 10MV " DEN 11 A i, R TO (tic DA 1 f i W NUM U M M 0 _9 1116 !p- 12-- ------- N_ T DRUP T I H �,l I - "Awn, A D!,,�,,� 13-- (M�NUI_ 10/1 TESJ H0,LE 13�0.11 11:55 30 4�25" 17/5" 3 11:56 Icy, 17 i OTTI 4 12:26 3.75- 5 12:27 1�50" 19 4AW 50" 1 12:57--- 10 2 0 PER(XN.ATRJN RA- I__..1 _JklIVINCH) PFR(HC)( F, DIA= 6 __CINCIII-_S) TI STRUN HFTWFFN`� M� FT. and 15FT, ihIL-r '-W Yaw Ppop to `IESPERFORMED BY ANDFASON F",N(ANFIATINU 1, N3ICTIA11, I`_ ANDERSON C-TAZT11"Y TIIAT TI IIS "'AS PIMINIMIA) IN ACCORDANCE NVIM ALT. STATE', AND MUNICIPLE GUMFLINNES IN F+_F_FC/T ON THIS MUNICIPALI ( Y OF ANCHORAGE [_)E- VFLC)PMENII' 'SEPV10E..<S DEF'/i.R1_MENT_ /,_70)0 BRA(. -,AW Sll FREE -i At:HORAGF, AK 991,519.6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: Lot 3, Grover SUbdivision PERFORMED FOR: HultgUist Homes DATE: 10/ 1 /2015 PROJECT No.: I"ARCE1, ID#: TECHNICIAN: W. Roberts DLPTH (f,eet) L= 2 3 4 5 6 7 8 9 1 I2 13 0 1 FR I (I / -)t; Silty Gravel GM 1516----� B.O.H. 17 18 19 20 SI C,,.)PF WAS OROL"NWVATER ENCOUN I FRED? No q 11, YES WHAT D111 I'll [ATTI I OF WA] ER Ai TFR NIONI 1 ORING: None Y IWILOVNION11'(RING: 5/15!16 4.4 �`l OF ........... N # 11. 4 9 t h .. ..... ..... MICHAEL E. ANDERSON No, CE -4381 ............... 4i.f'�ESS — SIFE PLAN See Site Plan D,�'�F RE4,,DiNG' "-ROSS Tlf�,117- (MINUTES) N: -:-,T HE- (M I N U T ES) L. E)EFITH �VAT (INCHES) NET DROF (I N CH F s), 10/1 _FEST HOLE SOAK F D PRIOR 10 -FEST! ING: 1 1:04 O.75" 2 1:34 30 3.75" 3.00" 3 1:35 1.t)0„ 4 2:05 30 4.00" 3.00" 5 2:06 1.25" 6 2:36 30 4,25" PERCOLATION RATE: 10 (NNIIN/INCH) PERC. HOLE DIA,�)(INCHES) TEST RUN BETWEEN:4.0 FT. and 5`.0 FTC CONIMENTS: _VES -i- HOLE PPE 'S.OAKFD PRIOR To TEST. EST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT TIJIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: I I/2/ 15 S89'58'1 2"E 155.00' N89'59'25"E 155.00' East 99th A Proposed Finish Grade PFG 579.0' Drainage Notes: Elevation 100.0' 1. All elevations are from approved grading plan. Ordered by: Hultquist Homes Inc. Legal Description: Plot Plan Lot 3. Grover Place Subdivision Survey Certification: I hereby certify that a Mortgagee's Inspection was performed on the described property. Notes: It is the owner's responsibility to determine the existence of any easements, covenants, or restriction which are not on the recorded subdivision plat. It is the contractor's responsibility to check top of foundation grade & building setbacks in relation to property lines and easements OF A ww0p F � 49TH .�f ................................. ................................. 9 -.Thomas H. Dreyer s 04 LS -7625 G p�a ••• d o �Ar app �n°fessiono� Expanded Redwood Legend: Proposed Well Septic Q Pavement Overhang Wood Deck Concrete Checked by: THD Drawn by: CB Scale 1" = 40' Grid SW2439 Job 2018-18 Field Book: XXX Plat 2016-74 Date: 4/25/2018 ePLIWZ • ; ;_ Municipality of Anchorage 61 On-Site Water and Wastewater Program .id I 111 (907)343-7904 SAICTY Certificate of On-Site Systems Approval Parcel I.D. 015-081-45 Expiration Date: 3 `Z- 1. GENERAL INFORMATION Complete legal description Grover Place Lot 3 Location(site address) E. 99th Ave. Current Property owner(s) HUItgUISt Homes INC Day phone Mailing address 12570 Old Seward Hwy Anchorage, AK 99515 Real Estate Agent Day phone 2. TYPE OF DWELLING: Single Family(w/wo ADU) ❑ Duplex ❑ Multiple Dwellings(Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 5 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: Date: COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ Waiver Fee $ Date of Payment �c �3/12 Date of Payment Receipt Number Receipt Number COSA# 05C-I MO 9)3 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are)safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are)in compliance with all applicable Municipal and State codes,ordinances,and regulations in effect at the time of installation. In conducting an adequacy test,I attempt to provide a thorough,conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations.The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition,ground water levels that may fluctuate during the year,and the water usage of the family being served by the system.These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system,nor do they guarantee that there are no hidden defects or encroachments.Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system.The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 272-8218 Address P.O. Box 100217, Anchorage Ak. 99510 Engineer's Printed Name Steven R Pannone Date 11/27/18 •� OF 6. DSD SIGNATURE �40U • • •- System#1 Approved for 5— bedrooms • Sleveri V.•Paririone: CE-8149 ?.. System#2 Approved for bedrooms Disapproved .FESSICtt Conditional approval for bedrooms, with the following stipulations: V\\,��t i " `` 'WATEPD C, ON-SI T E � j VI/ASTEWAND m ATER PROGRAM • By Original Certificate Date: Z -( The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA)based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet f • .. If more than 1 septic system is on the lot: COSA Checklist# 1 of 1 Structure served by this system 1 Certificate of On-Site Systems Approval Checklist Legal Description: Grover Place Lot 3 Parcel ID:015-081-45 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log(Y/N) Y Date completed 9/20/18 Sanitary seal (YIN) Y Wires properly protected(Y/N) Y Total depth 124 ft. Cased to 124 ft. Casing height(above ground) 24 in. FROM WELL LOG AT INSPECTION Date of test 9/20/18 new Static water level 57 ft. ft. Well production 25 g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform neg colonies/100 mL Nitrate ND mg/L Arsenic ND ug/L Date of sample: 1 1/20/18 Collected by: PES B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic / Steel Date installed 7/16/18 Tank size 1500 gal. Number of Compartments 2 Cleanouts(Y/N) Y Foundation cleanout(YIN) Y Depression over tank(Y/N) N High water alarm(Y/N) N/A Date of pumping N/A (new) Pumper C. ABSORPTION FIELD DATA Date installed 7/16/18 Soil rating2 z 0.8 Deep Trench (g.p.d./ft or ft2/bdrm) System type Length 45/45 ft. Width 2.5/2.5 ft. Gravel below pipe 6/6 ft. Total depth 10 ft. Eff. absorption area 1080 ft2 Monitoring tube Y Depression over field N Date of adequacy test N/A (new) ResultsPass/Fail pa SS 5 ( ) For bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment(past 12 mo.)(Y/N&type) If yes, give date D. LIFT STATION Date installed N/A Size in gallons Manhole/Access(Y/N) "Pump on"level at in. "Pump off'level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 1001+ 4., On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main 751+ Public sewer manhole/cleanout 100'+ Sewer/septic service line 25'+ Holding tank N/A Animal containment areas N/A Manure/animal excrete storage areas N/A SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10i+ Property line 10'+ Absorption field 10'+ Water main 25'+ Water service line 25'+ Surface water 100'+ Wells on adjacent lots 100'+ ABSORPTION FIELD ON LOT TO: Property line 1 01+ Building foundation 10'+ Water main 101+ Water Service line 25'+ Surface water 100'+ Driveway,parking/vehicle storage 101+ Curtain drain 50'+ Wells on adjacent lots 100'+ F. COMMENTS Survey on file G. ENGINEER'S CERTIFICATION 4••"`' A[\v\ I certify that l have determined through field inspections and ofCoo.• )4•111 --*y�.y'F review of Municipal records that the above systems are in "4:',9 1- �\ •*y conformance with MOA COSA guidelines in effect on this date. 0•••• =:�'��`` 0 Steven R. Pannone Engineer's Printed Name i••:S1eWn PonnOne• Af Date #0(I-2 CE-8149 �,� �/ fiko • i • 4 `\\`N_'_ COSA canary sheet,2-6.15.doc