HomeMy WebLinkAboutMOUNTAINSIDE VILLAGE #1 BLK 6 LT 4 Onsite File Mountainside Village # 1 Block 6 Lot 4 #020 - 172 - 32 tr<ev voivu 10) Municipality of Anchorage On-Site Water and Wastewater Section Y (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181139 PID Number: 020-172-32 Dwelling: ❑ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑ Upgrade Name Bradley &Kay Underwood ABSORPTION FIELD ❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound Site Address 7140 Big Mountain Dr. Anchorage, AK ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 519-2932 2 1.2 GPD/SF 0.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade +0.5 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot Mountainside Village #1 6 4 Fill added above original grade 2.7 Ft. Gravel length 50.0 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 250 Ft2 1 Ft. Well >100' >100' N/A NIA >25' TANK A Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity Greer 1000 Gal. Surface Water >1 >1 00' N/A NIA Material Number of compartments Lot Line >5' >10' N/A N/A NA Plastic 2 Foundation >10' >1 0' N/A N/A LIFT STATION Manufacturer Capacity Remarks Tank, line from house to tank, and Gal. absorption trench are insulated. Alarm location Electrical installed by PIPE MATERIAL House to tank D3034 Tank to drainfield D3034 Installer Owner install Drainfield D3034 CO/MT D3034 Inspector B. Schiller BENCH MARK (Assumed elevation) 100 ft Inspection 15' 6/25/18 Location and description nd Top of foundation center of West wall. 3rd 4m ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp �., Conditional Approval: Date ���1�� " °' AdV °~ 49th 0 ............. I...... ............. ..C..a........ .� ' ��:.�MIcrIAEL E. ANDERSONAll '�' No. CE-4381 ? .�� ®0�TF.,. Septic System 4� n^ �I Approved `xti'�� " Date �� 0 9/28/20 °��'� Note: this approval does not include well permit requirements. tr<ev voivu 10) C16/01/220,18 23: 25 M -i -34i5-3202 ALPLNE DRILLING PAGE 01/01 U 'aim IT Permit Number: NSW I81139 Date ijflssukc:6-12-18 Parcel Identification Number. 020,17232000 Date Started: 2,: �7-1 8 Date Completed: 9-19-16 Is we)) tocated at approved permit loccadon? x, Yes �j tau Lrcg,.-,l Description: Villag,,-,, 94 8,rock- 6 Lot 4 Propertly Owner Nx.ne & Address.- Br&(PP 'I/ & Kay Ur)(101WOod 17800 Ashland Drive --Anchorage, Aias-.ka 99516 Borehole Data., Depth (ft) Method of Drilling x air rotiry Dcabteteat Soil Type, Thickness & Water Scram Trott) T-1) — stick-lTm bedi,ock C 2 WATER QUALITY TESTING C04b" Ne-Q� COU100ML Nitrates 2 --6'1 mg/L ArseNc Nb UWL jai 519-1 W22 Casing typt-. steei Wall ThiAnes,;. Its ittche8 6 Diame%--r. 6 inches Dq4i: 42'..) feet Liner Type: — Diameter: ireb c,, Dep,h feet . e, t Casingst LC�Cutl aboe -rcuad.- 2 Static water level (11kom ground level;: Pumping level.: �4q.'JWt after 9 hours Pumping - 4-1 gpni Recovery Rate.- 75 gpm MtAhud of Testing:.Air - -- W, Well Ahe opexdrlg'rype: I❑j Open End x Opern Hole F-1 Scrf-eT)ed Stall — feel Stopped few E -j Ferfur ,mions Start __feet Stopped feet Grout Type.- jenLcy 1ii(Lq granules Volume: U19f . DepiL ......... Start (; feet Stoppied 112 feet Famp. Intake Deptb feet Pump size --- ' hpBrxid Narne, Well Disinfected Upoo Completion? x Yes No Method of I)Wnfecdun; Coal mentr,-.- Well Driller; Alpine Driilin� FO Box 1104-96' Anchorage AX 99511 07/ 0 3 /21 0 1 3'2 9 10 -1-1 - __11 4 15 - t� 2 021 ALPINE DPJLL_,j,!G p4GE oi/ol MUNIUCIrIALITY COF A NCHORAGE evelopment Services Department PE ooe: 907-343-7904 On -Site Water & Waz;lewater Section %Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: . 181139 Date of Issue," 6 - 12 -18_ Parcel Identifleation. Naniber. 020 172 32C Legal Deser, )tioa R19ek Lot llrr(neVy 0-vvner Nan -it & Addre.�,,4: 8 a6 , Mountairside \%age 16 4 ,oRq,)od 178CO AsHand Dr. llk)chorags AK 99516 pUnIp jr1q;fflation Date, W -25 _2018 Pian p Intake Depth below Top of Weil Casing; 423_,,,___ feet Pump '_'Manufactixrer'ii Name: Goulds Pump Model: 5HS10 Pump Sim: 1 _hp Fittess Adapter Burial Depth.4 — feet Pitless Name' Martensen Pitlem Adapter Installer: A Aa. row PU F,(.)p & We., I Well Disinfected Upon Completior)? Yes 0 No Methad of Disinfection- Gfliol'ille tables Comments: PLEASE SAVE FOR COSA. Pump Installer Name: Company: Aarow Pump & Welli Service :',failing Address; P. 0. Box 110496 Anchorage State., AK`___.. __Zip! 99511 Attei1tion. The putop installer shalt provide a pbnip instal latioll log to Or,-sifi4 witliin 30 days o-E'pwz-p installation. Lr N,c"""'Y MUNICIPALITY OF ANCHORAGE mens On-Site Water&Wastewater Program -NoePO Box 196650 4700 Elmore Road Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 ;. '" http:l/www.muni.orgfonsite t ' f 1)cpart n1(11t 4'/C HOIi On-Site Water & Wastewater System Permit Permit Number: OSP181139 Effective Date: 6/12/2018 Work Type: WellSeptic Initial Expiration Date: 6/12/2019 Tax Code Number: 02017232000 Site Legal Address: MOUNTAINSIDE VILLAGE#1 BLK 6 LT 4 G:3439 Site Mailing Address: 7182 BIG MOUNTAIN DR, Anchorage Owner: UNDERWOOD BRADLEY & KAY Lot Size in Sq Ft: 156191 Design Engineer: FORGE ENGINEERING Total Bedrooms: 2 This permit is for the construction of: Q Disposal Field El Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: V ,�( /J t / Date: 1 Issued By: 114 SCC A Date: (.6,A1, MUNICIPALITY OF AN 995 AGE • Community Development Department aP • e: 907-343-7904 Development Services Division JUN 1 1 2018 - -47-34 -7 97 On-Site Water & Wastewater Program 4 ti ON-SITE SEWER/WELL PERMIT ,'°I* • _ $ a ► 40.1.1 Parcel I.D. 020-172-32 Property owner(s) Bradley and Kay Underwood Day phone 519-2932 Mailing address 17800 Ashland Drive Anchorage, AK 99516 Site address NHN Big Mountain Drive Anchorage, AK 99516 Legal description (Sub'd., Block & Lot) Mountainside Village #1, Block 6, Lot 4 Legal description (Township, Range & Section) Lot Size 156,191 Sq. Ft. Number of Bedrooms 2 (Two) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field X Initial X Single Family (SF) IXI (w/wo ADU) Septic Tank X Upgrade ❑ Duplex (D) Holding Tank ❑ Renewal ❑ Multiple Dwellings Privy ❑ (SF and/or D) Private Well ❑X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. -004 . (Signature of property owner or authorized agent) Permit/Rush Fees: cit fadNO Waiver Fees: Date of Payment: Co f 12 f l g Date of Payment: Receipt Number: 050-3b Receipt Number: Permit No. 0$P1 'I m9 Waiver No. Permit App_'•' ;:...c; Imo.. �, ) ' GE ENGINEERING PO BOX 240773 ANCHORAGE,AK 99524 522-7773 677-7766(FAX) June 11, 2018 Municipality of Anchorage Development Services Dept-On-Site Water&Wastewater Program 4700 Elmore Rd Anchorage,AK 99507 Subject: Mountainside Village#1 Block 6,Lot 4—Big Mountain Drive Septic System Design and Permit Application Dear On-Site Services Engineer: The owner of the above lot intends to build a 2-bedroom home on the property. We are submitting this permit application for the construction of a new well and septic system to serve the home. The attached site plan identifies the location of the home and the proposed well, septic system and alternate site.No conflicts exist between the proposed system and any other well or septic system on the adjacent lots. The ground surface on the lot slopes to the west at grades from 16% to 20% in the area of the proposed system. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Drainage arrows and surface contours are shown on the site plan showing the grade and direction of flow. Storm water drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100' from all wells and surface water, and more than 5' away from the septic tank. The alternate site is located more than 10' from the primary site. Please refer to the attached test hole logs,plan and profile sheets for the septic design. If this design is followed,there will be no adverse impacts to adjacent properties. Sincerely, \\ OF A• ,'• S� Michael E. Anderson, PE (* 49 TH *0, Michael E.Anderson SOA es••. 4381-E ;fag `ll%PROFEsso0,`. MOUNTAINSIDE VILLAGE #1 BLOCK 6 LOT 4 S' _______7:77, „ I ,o,i i i i i..i i,.i.,,1 i,,,,,i. -.y.•i.e.—A.,.. - --,,—-i.---_.... _ _______ i1 \ ....,..___......,..,y0-•"'"....-- ,................,.........i....,......, _,---------------,,_,\_____,______ EXISTINGWELL" 7�zr • il 71110111111.-,1.1° 6:1GTZ \ * 'Al;/o 7 \ ., LOT 5 44 • 0 ` ` �` �``�.-10'T&E EASEMENT .� GE ���.\\\,, NO SLOPES>25%WITHIN 50'OR SURFACE WATER WITHIN 100'OF THE LEGEND OF e! - 1 PROPOSED SEPTIC SYSTEM r�G.•••'A•49 -1 CO-CLEANOUT �reb.• . ,1 • A.-'*.:17 TA 2C0-DOUBLE CLEANOUT /*:,91}i ) *I ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS •• ? / PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC FCO-FOUNDATION CLEANOUT 6 nib; :1- SYSTEMS. FS FLOW SPLITTER VALVE : Michael E.Anderson . / 0 100 200 MH-MANHOLE 1 f•. :`( i MT-MONITORING TUBE F -1 / FEET �t , p'••.�i✓.�e'% SV-SEPTIC VENT ll ��PROFESSIONP. . 1"=1o0' TH-TEST HOLE MOUNTAINSIDE VILLAGE #1 BLOCK 6 LOT 4 S' /:\\ 7.----/ /:///.---7------ , "------ ------------ ---- ApmioOP'Am10lIlliwgrr-'slliii Lao,/ . • / / 41°.° k'A."1". it 1 l� , ;• � ?' dN x 'E .5' -FF AllilliV x `20. Q" • •--T A:..4P • -,CH . / i : f'S°1 tiii-11; • . .:. i/ .I4/ d7 Q 1/11 \•• 6- A', : • i - .�T. . T • ep..Y I � _____ . \ S\4\/ I. 5' •E , a I( ,4 1 ,...y / C'''-- I.:. 44# ilk* '.' \ \\\_\,// L \\\\\\\\\\�:��\ \ _ _ _ GE'''''N-NX 1N01N1[lIN6 \N-.. e ` `���\\\\ NO SLOPES>25%WITHIN 50'OR SURFACE WATER WITHIN 100'OF THE LEGEND ,r,�OF \�ki� PROPOSED SEPTIC SYSTEM CO CLEANOUT AP'(b..' • y'+ 2C0-DOUBLE CLEANOUT %*;49 TH iN * ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS • •• ••• ,� PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC FCO-FOUNDATION CLEANOUT 6�i�ha Zl;n MT-MONITORING TUBE Michael E.Anderson : / S0YSTEMS. 50 100 TH STEST IC VENT •. / ��FJ'l'F..c 4831-E 4.•* �AO FEET CONTOUR INTERVAL-2' tk%'PeP'R ...10NA�� 1"=50' MOUNTAINSIDE VILLAGE SUBDIVISION #1 BLOCK 6, LOT 4 DESIGN FACTORS: SYSTEM REQUIREMENTS: 300 GPD PEAK FLOW 5' WIDE SHALLOW TRENCH SYSTEM PERK RATE: 1-5 MIN/IN 1,000-GAL SEPTIC TANK APPLICATION RATE: 1.2 GPD/SF 300 GPD / 1.2 GPD/SF / 5' WIDE * 1.0 = 50 LF TRENCH REQUIRED (50 LF SPECIFIED) BOTTOM OF TRENCH: 0' BELOW GRADE (HIGH SIDE) FLOW LINE ELEVATION: .5' ABOVE GRADE (HIGH SIDE) TOP OF TRENCH: 3' ABOVE GRADE (HIGH SIDE) TOPSOIL AND REVEGETATE SLOPE TO PREVENT EROSION 3 2' 7— 2" INSULATION 3 1 __ 4" PERFORATED PVC 1 ::::::: ::::. . . :• _ : (HOLES DOWN) .h-:�E•,�,.t�, a • w „._ 4'.r: DRAINFIELD ROCK ;�ti}�'<�nr.;311•M i.,,>v.-ate'•.�i '�",•... ::^,''Ct•'.,.:.�: 1' `` ' ' ` ' •• REMOVE ORGANICS AND PLACE xrT t':��i-til."�.Y y�'.��' MOA APPROVED SAND 5' GE IN4INEEEIN4 TYPICAL WIDE TRENCH SECTION ,�, � � (NO SCALE) /' b.f• G.• _I ?,Pli NOTES: 0*• 49Th •4 1. GRADE AREA OVER TRENCH TO DRAIN AWAY �� ZGJ1t 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' /A "••MichaeelE.Anderson .� Aer- WITH 2" OF INSULATION �� F• -if-I'1f• ``'.�/ 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER l��FaPRpFESS10�P,�! THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY `� MUNICIPALITY OF ANCHORAGE _�,4 F... �Ikk DEVELOPMENT SERVICES DEPARTMENT /:*:._.... ...__�-''.•;9,+ 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 0*::49TH. ,\. . ley SOILS LOG AND PERCOLATION TEST �/ : Michael E.Anderson .� LEGAL DESCRIPTION: MOUNTAINSIDE VILLAGE #1 B6 L4 \���oFEss PERFORMED FOR: BRAD UNDERWOOD DATE: 5/28/18 PROJECT No.: Professional Engineers Stamp: PARCEL ID#: 020-172-32 TECHNICIAN: J. MILLETTE DEPTH TEST HOLE 1 (feet) 1' OB SLOPE SITE PLAN 1 ;� 2 !,: +.; MUNICIPALITY OF ANCHORAGE `;C AC,4044 DEVELOPMENT SERVICES DEPARTMENT ; Y:. �I�\\‘‘,'yt# 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 *• 4®TM )� %*g 41:1411. j����"1 SOILS LOG AND PERCOLATION TEST / : Michael E.Anderson:� FA k 2..1-1 A..(c ��/ LEGAL DESCRIPTION: MOUNTAINSIDE VILLAGE #1 B6 L4 k FOPROFESS\0 PERFORMED FOR: BRAD UNDERWOOD `\\�����'4-` Professional Engineers Stamp: DATE: 5/28/18 PROJECT No.: PARCEL ID#: 020-172-32 TECHNICIAN: J. MILLETTE DEPTI I TEST HOLE 2 (feet) 1 1 1-;;;F;.:.?;:.! 1' OB SLOPE SITE PLAN 3 :,.,,. '-.?, r:,. .`;. SANDY SILTY GRAVEL 4 :.•-f' : SM 5 • ,,: SEE SITE PLAN 6 '•BE ' z ROCK 7 8 9 10 WAS GROUND WATER ENCOUNTERED? NO IF YES @ WHAT DEPTH? DEPTH OF WATER AFTER MONITORING: NONE 11 DATE OF MONITORING: 6/11/18 12 DEPTH TO DATE READING GROSS TIME NET TIME WATER NET DROP 13 (MINUTES) (MINUTES) (INCHES) (INCHES) 14 5/29 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 1 12:42/12:50 7:40 5/ 11 6 2 12:56/13:06 10 5150 1016 41g 16 3 13:07/13:17 10 516/ 1016 416 17 4 13:18/13:28 10 516/ 1016 416 18 5 13:29/13:39 10 516/ 1016 4 i4 19 6 13:40/13:50 10 516/ 1016 416 20 PERCOLATION RATE: 2.4 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 2 FT. and 3 FT. COMMENTS: 6/12/2018 Septic owner builder form.jpeg MUNICIPALITY OF ANCHORAGE Development Services Department \ // Phone: 907-343-7904 On-Site Water&Wastewater Section Fax: 907-343-7997 Septic System Owner-installer Agreement The On-site Water and Wastewater Section (On-site) may issue an approval for a homeowner to perform work on an on-site wastewater disposal system to serve that individual's owner- occupied, single-family or duplex home if the homeowner meets and agrees to the following requirements: 1. The property owner and excavation equipment operator may perform work on no more than one owner-installation project in a 12-month period. 2. Owner's projected active involvement with the installation: Perform all necessary tasks required to satisfy all criteria and specifications of approved septic design 3. The name of the excavation equipment operator: Brad Underwood 4. I agree that there will be no monetary compensation for installation services rendered. 5. The name of the inspecting engineer: Jacob Millette/Ben Schiller 6. I agree to discuss the following items with the inspecting engineer: a. Permit design criteria and specifications. b. Inspection requirements set forth in AMC 15.65.070. c. Advance notice given to the On-site Water&Wastewater Section for all required municipal inspections(AMC 15.65.070A): 7. I agree to have the project-specific On-site Wastewater Disposal System Permit available at the construction site for the duration of all related work. 8. I agree that if the system is an advanced wastewater treatment system (AWWTS), I will obtain additional installation instructions and approval from the equipment distributor. As owner of(legal description) 140 'MYj5* V;1/1114— / "/k 6 L.-1- I -fI agree that the information above is true1and accurate. Owner's printed name: T1'A�I VI✓I�I 1,11Vt4 Owner's signature: ,61/t4 I/v+4Li " 2 Date: 6//2-1/? Mailing Address: P.0.Box 196650' Anchorage.Alaska 99519.6650'www.muni.org https://mail.google.com/mail/u/0/#search/bradleyw52%40gmail.com/163f4e451972dc79?projector=1&messagePartld=0.1 1/1