Loading...
HomeMy WebLinkAboutDENALY ESTATES BLK 2 LT 2 Onsite File benaly Estates Block 2 Lot 2 #067 - 062 - 09 Municipality of Anchorage On-Site Water and Wastewater Program • (907)343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181238 PID Number: 067-062-09 Dwelling: 0 Single Family (SF) ❑ Duplex (D) El Multiple (SF and/or D) Project: 0 New El Upgrade Name: ABSORPTION FIELD Troy Davis Homes Address ❑ Deep Trench E Shallow Trench El Bed El Mound 1689 Knik Goose Bay Rd 400 Wasilla, AK 99654 El Other Phone Number of Bedrooms Soil Rating Total depth from original grade 310-2501 3 1.2 GPD/SF 2.5 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 1.0 Ft. 1.5 Ft. Denaly Estates 2 2 Fill added above original grade Gravel length Township Range Section 2.1 Ft. 62.0 Ft. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES 5.0 Ft. Ft. ToSeptic Absorption Holding Sewer Total absorption area Number of trenches Dist.between trenches Tank Field Lift Station Tank Line From 397 Ft2 1 Ft. Well >100' >100' N/A N/A >25' TANK 0 Septic ❑S.T.E.P. ❑Holding 0 Other Manufacturer Capacity Surface Water >100' >100' N/A N/A Anchorage Tank 1000 Gal. Material Number of compartments Lot Line >10' >10' N/A N/A Steel 2 NA LIFT STATION Foundation >10' >10' N/A N/A Manufacturer Capacity Curtain Drain None Noted Gal. Pump on level at Pump off level at High water alarm at Remarks Tank and trench are insulated. in. in. in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank D3034 Tank to D3034 Installer drainfield Northern Excavation Drainfield D3034 CO/MT D3034 Inspector J. Millette BENCH MARK (Assumed elevation) 100 ft Inspection 15' 8/30/18 2nd 8/30/18 Location and description 3rd 4th Top of foundation at South wall. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp` t Conditional Approval: Date .. A . .. •. Q l� • %g,P ,j,...1,1#� /*:49TH /\ •* / /� • Benja. chiller • . 11 9F• CE 12592 ••.�Q./� 22 , 'fl• 1/21/19 •••• •- Approved ( �-, / Date !�J1 q ll�l�PR•oFiS$10*�= Inspection Report_9-1-12.doc DENALY ESTATES, BLOCK 2 LOT 2 S' PERMIT # OSP181238 PID # 067-062-09 � � !. �! „�.. .364 6._ s—.-z � \ �+' i\FSS`1��r� , • ,...,„1,. _. \ ,1 til_, UNDEVELOPED \ Lot 3 EXISTING WELL 100'WELL RADIUS -----____.... ( UNDEVELOPED � ; 1000-GAL SEPTIC '' l' TANK u i' 0 O /1, ..."-/ c'2 62'LONG x 5'WIDE,1.5' / EFFECTIVE DEPTH ABSORPTION TRENCH •'o.SV2'Sc� / ,iz•. I • P.7... ct'. (apt25 , I i \N ALTERNATE SITE • THE/ • Z . . • \N \N .. Lot 2 \ N. o \\, 11, ' - ' —\i% -4t\24:::::-___\ . , \_` t ` j _- \ ,CS1 / ` \\\ 'tot 23 t\ illtGE EMGIMf[RING A B LEGEND FCO , 3.8 50.5 CO-CLEANOUT 4•,..��.N"W SV1 20.5 55.9 2C0-DOUBLE CLEANOUT ,�OF AL,glli SV2 , 26.2 58.5 FCO-FOUNDATION CLEANOUT 2C0 29.7 60.2 FS FLOW SPLITTER VALVE f4;TM �` or TA PLAN AS-BUILT Col 36.6 76.0 ?� MT1 35.1 72.9 MH-MANHOLE --i ;.— CO2 62.1 40.0 MT-MONITORING TUBE 8enja in Schiller MT2 59.5 39.1_ SV-SEPTIC VENT ** CE 12592 •.4,/� 0 100 200 TH-TEST HOLE tole •.Jn.2..20.8 •'.� .+� ME = um Om FEET IkVPRoFEssio��` A\\�N�`+. 1"=100' DENALY ESTATES, BLOCK 2 LOT 2 PERMIT # OSP181238 PID # 067-062-09 o (V 0 LLL U) Cl) CV - ,- 98.4 - - - 96.4 2" INSULATION S..." 7I 95.8 1000 GAL 95.6 I I SEPTIC TANK <- 91.6 2" INSULATION 0I- 97.8 FINISH GRADE o C?�f 95.7 ORIGINAL GRADE U _ _ __ w 94.7 — 94.7 DR\INFINLD ROCK �----- 93.2 62' 93.2 1"-'-- 87.2 GROUNDWATER ENCOUNTERED 7/28/18 83.7 (V I I--- of 4Itaki ;4:449 TM 1" �9*+,l '%6• . : % Ben alifin Schiller . PROFILE AS-BUILT o��-Fc CE22592 . ••�� illt*GE (NO SCALE) '�l�F'PROFESSION�� = 4.0N0C1VAlItY0 MUNICIPALITY OF ANCHORAGE n,t►,r On-Site Water&Wastewater Program 10 50', PO Box 196650 4700 Elmore Road •• -Agee Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 "► http://www.muni.org/onsite . � Department 4kCMOR On-Site Water & Wastewater System Permit Permit Number: OSP181238 Effective Date: 8/7/2018 Work Type: WellSeptic Initial Expiration Date: 8/7/2019 Tax Code Number: 06706209000 Site Legal Address: DENALY ESTATES BLK 2 LT 2 G:0362 Site Mailing Address: 25460 MC INTYRE RD, Eagle River Owner: TROY DAVIS HOMES INC Lot Size in Sq Ft: 72502 Design Engineer: FORGE ENGINEERING Total Bedrooms: 3 This permit is for the construction of: 2 Disposal Field E Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: The recorded plat for this subdivision notes that artesian wells are common and that special drilling methods may be required to prevent waste of water via surface discharge. PO/Received By: VP/WU P(/ Date: / 111 Issued By: -6i1)-6CADate: O 1 8 ECIANS MUNICIPALITY OF ANCHORAGE a1l Community Development Department '{ =` Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On-Site Water& Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 067-062-09 Property owner(s) Troy Davis Homes Day phone 310-2501 Mailing address 1689 Knik Goose Bay Rd #400, Wasilla, AK 99654 Site address 25460 McIntyre Rd Legal description (Sub'd., Block & Lot) Denaly Estates Block 2 Lot 2 Legal description (Township, Range & Section) Lot Size 72,502 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (El all that apply) Absorption Field ❑X Initial U Single Family (SF) U (w/wo ADU) Septic Tank X Upgrade Duplex (D) ❑ Holding Tank n Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well VC Water Storage THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 7 74 Waiver Fees: Date of Payment: x`311143 Date of Payment: Receipt Number: (15-2510 b Receipt Number: Permit No. (MP/Y/2,31 Waiver No. Permit App_.-: ::.,c PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) July 30, 2018 MOA Development Services Dept, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Denaly Estates Block 2 Lot 2 - Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 3-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes down away from the road at a moderate slope, between 5- 15%. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Drainage arrows are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 10’ away. Please refer to the attached test hole logs, soils lab analysis, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE 7/30/18 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181238, Rebecca Carroll, 08/07/18 33 0 . 0330.034 0 . 0 350. 0 36 0 . 0 3 7 0 . 0 380.0 390.0 332 . 0 334.0 336.0 3 3 8 . 0 342.0 344.0 346. 0 348 .0 35 2 . 0354.0 3 5 6 . 0 358. 0 362.0 3 6 4 . 0 366 . 0 368.0 3 7 2 . 0 374.0376.037 8 . 0 382.0 384.0 386.0 38 8.0 392.0 9 4 . 0 9.9%5.0%3.5%1 1 . 3 %FCO 200100 0 FEET 1"=100' 60' LONG x 5' WIDE, 1.5' EFFECTIVE DEPTH ABSORPTION TRENCH 1000-GAL SEPTIC TANK NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND CO TH#1 DENALY ESTATES, BLOCK 2 LOT 2 Jul 30, 2018 SLOPES > 25% SLOPES > 46% 15' T&E EAS E M E N T 10' T&E EASEMENT20' DRAINAGE EASEMENTALTERNATE SITE 2CO TH#2 CO MT UNDEVELOPED UNDEVELOPED Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181238, Rebecca Carroll, 08/07/18 DENALY ESTATES BLOCK 2 LOT 2 DESIGN FACTORS: SYSTEM REQUIREMENTS: 450 GPD PEAK FLOW PERK RATE: <1 MIN/IN APPLICATION RATE: 1.2 GPD/SF* 5' WIDE DEEP TRENCH SYSTEM 1000-GAL SEPTIC TANK TYPICAL DEEP TRENCH SECTION (NO SCALE) Aug 07, 2018 NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY BOTTOM OF TRENCH: 2.5' BELOW GRADE FLOW LINE ELEVATION: 1.0' BELOW GRADE TOP OF TRENCH: 1.5' ABOVE GRADE 450 GPD / 1.2 GPD/SF / 5' WIDE * 0.78 REDUCTION = 58.3 LF TRENCH REQUIRED (60 LF SPECIFIED) 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 5' 6" 1'-6" 6" 1'-6" INSULATION *SEE ATTACHED LAB ANALYSIS CATEGORIZING MATERIAL AS SW-SM Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181238, Rebecca Carroll, 08/07/18 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 1 SLOPE SLOPE SITE PLAN See Site Plan DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) Denaly Estates Block 2 Lot 2 7-6-18 N. Shafer Development Services Department 4700 Elmore Road Anchorage, AK 99519-6650 Municipality of Anchorage DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH OF WATER AFTER MONITORING: IF YES @ WHAT DEPTH? YES 9' 8.5' 0.19 6 3.5 4.5 067-062-09 Troy Davis Homes Professional Engineers Stamp: Jul 30, 2018 14:00 - 14:01 2/21 1 2 3 4 5 6 4 0 16 - 10 0 16 14:01 - 14:02 14:02 - 14:03 14:04 - 14:05 14:05 - 14:06 14:06 - 14:07 1' OB WELL-GRADED SAND WITH SILT 7/28/18 SW-SM SILTY LOAM 6 0 16 "1:05 1:05 4 - 10 6 1:06 4 - 10 6 1:10 4 - 10 6 1:09 4 - 10 6 1:10 4 - 10 6 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181238, Rebecca Carroll, 08/07/18 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 2 SLOPE SLOPE SITE PLAN See Site Plan DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) Denaly Estates Block 2 Lot 2 7-6-18 N. Shafer Development Services Department 4700 Elmore Road Anchorage, AK 99519-6650 Municipality of Anchorage DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH OF WATER AFTER MONITORING: IF YES @ WHAT DEPTH? YES 8.5' 8.5' 0.35 6 3.5 4.0 067-062-09 Troy Davis Homes Professional Engineers Stamp: Jul 30, 2018 14:25 - 14:26 2/21 1 2 3 4 5 6 4 0 16 - 10 0 16 14:27 - 14:28 14:29 - 14:30 14:31 - 14:32 14:33 - 14:35 14:36 - 14:38 1' OB WELL-GRADED SAND WITH SILT 7/28/18 SW-SM SILTY LOAM 6 0 16 "0:58 1:20 4 - 10 6 1:39 4 - 10 6 1:49 4 - 10 6 2:05 4 - 10 6 2:09 4 - 10 6 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181238, Rebecca Carroll, 08/07/18 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181238, Rebecca Carroll, 08/07/18 O w W Z V m 0 0 O K a m ° it �O N z O Q Z M Q ao+ 04 �W M W In W 0 m L'iU NO o. E c Z L Q N o K 0 0 � N w d U U n 0 CL p + N Z e0 O arno°oo vNEauo � J W W O O J ° o E q m V m o r J ++ rnz+c-Et 0 0 O K a m ° it �O N z w M O w w w aw O �a ao+ w � J um 0 w N N N N N N M M M M M M M M M M M M M M M M M M M �OIWrnrnO�O�O�O�O�O�O�O�O�W mO�OIWT�O�T0�0� U U U U U O 0 M M M M M M M M M M M M M M M M M M M M M M M M d V) <Mocwwo=—�MzOo_C7�D>3:x Z O U Q ZMOha'�tOM7t0 o]M OI�MOh Nd'I�NOhI�N N N NU N cp N N N 44Ili N N M vi 46 LJ N c0 c0 cD cD N c0 c0 (O t0 t0 t0 t0 tD tD c0 �O �D �D N c0 [O c0 (O c0 W w M M M M M M M M M M M M M M M M M M M M M M M M M N \ J \ N / +s / / of 06 / N w ,ry t4 / o / of N n J W m Z W W ix W W J Q W Y m la O Z 0 m o O CL` c ° c O x L O mo.L� o < v to Lo a I I Z I 0 N N N N c o onn &aoo 0-00) ° Y •: Q •Z - J.• 4aw Z O �a ao+ ° Y 's O �a ao+ v °o m n v c `° 0 m o 0 o. E c + 000> a o0 0 0 � a.2 0ro 0.0m n 0 CL p + N J O arno°oo vNEauo J o° o`o M 00>0.mc am Z — O ON °' ° OO ° o E q m V m o r O ° y b m ++ rnz+c-Et c C 0+ C9 C O E O O`:E 0 0+ V o °a.9 1 mp m ME C C O O C `o W° m 3 n C O o + C o y Y 0 ° 0 W y c 0 O O en W 9 C 0 O m L o ice o 3 >�toa°� t ay o o a ZD w n 00 OLEO a ot a A+ o c o v Nfmre a+ p 0 O. c` y nm p w Cm�aEe0 no o U mm 2° y y O �«o amy° +o m p 0 C mgr -0E0 n em r ao _ a3c o soo RVISA, LANs MUNICIPALITY OF ANC RAGE /. Development Services Department i Phone: 907-343-7904 On-Site Water & Wastewater Section - . Fax: 907-343-7997 Certificate of On-Site Systems Approval Parcel I.D. 067-062-09 Expiration Date: �I 1. GENERAL INFORMATION Complete legal description Denaly Estates Block 2 Lot 2 Location (site address) 25460 McIntyre Road Current property owner(s) Troy Davis Homes, Inc Day phone 907-310-2501 Mailing address 1689 Knik Goose Bay Rd, #400, Wasilla, AK 99654 Real estate agent Day phone 2. TYPE OF DWELLING: Single Family (w/wo ADU) El Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well [ Private Septic Water Storage ❑ Holding Tank Community Well ❑ Community C Public Water System [ Public Sewer ❑ Waiver request for Distance: Received by: Date: COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ a /gin Waiver Fee $ Date of Payment /l a�-i/"7 Date of Payment Receipt Number USiL-1 3/D Receipt Number COSA# 0Oc[ i 10/S Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Forge Engineering Phone 907-522-7773 Address PO Box 240773, Anchorage, AK 99524 Engineer's Printed Name Benjamin Schiller, PE Date 1/21/19 of A•C q614$ * • '4®TM A� * fi i ' 6. DSD SIGNATURE % • VP.... ;• •. ..• p xSystem #1 Approved for 3 bedrooms / �.: Benja• chiller j System #2 Approved for bedrooms ���G 1/• C21/19 . / �v9Fo:O•.SS10HtV.s Disapproved l�,�w"`w Conditional approval for bedrooms, with the following stipulations: • avj 2 WPSE wP�R o. o W PROGRAM s' 'f'fNT Svc By: k—,—dd Original Certificate Date: / — 23-1/ The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: Denaly Estates Block 2 Lot 2 Parcel ID:067-062-09 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) Y Date completed 8/23/18 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 143 ft. Cased to 143 ft. Casing height (above ground) 24 in. FROM WELL LOG AT INSPECTION Date of test 8/23/18 NEW Static water level Artesian ft. ft. Well production 20 g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform Neg colonies/100 mL Nitrate ND mg/L Arsenic ND ug/L Date of sample: 1/15/19 Collected by: Forge Engineering B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 8/30/18 Tank size 1000 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout(Y/N) Y Depression over tank(Y/N) N High water alarm (Y/N) N Date of pumping Pumper New Construction C. ABSORPTION FIELD DATA Date installed 8/30/18 Soil rating (g.p.d./ft2 or ft2/bdrm) 1 .2 System type Shallow Trench Length 62.0 ft. Width 5.0 ft. Gravel below pipe 1 .5 ft. Total depth 4.6 ft. Eff. absorption area 397 ft2 Monitoring tube Y Depression over field N Date of adequacy test NEW Results (Pass/Fail) For bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment(past 12 mo.) (Y/N &type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot >100' On adjacent lots >100' Absorption field on lot 100' On adjacent lots 100' Public sewer main >75' Public sewer manhole/cleanout >100' Sewer/septic service line >25 Holding tank 100 Animal containment areas >50' Manure/animal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO: >10'Building foundation Property line >5 Absorption field >5 Water main >10' Water service line >10' Surface water >100' Wells on adjacent lots X100' ABSORPTION FIELD ON LOT TO: Property line 10 Building foundation 10 Water main >10 Water Service line Surface water 00 Driveway, parking/vehicle storage >10' Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS G. ENGINEER'S CERTIFICATION .`����\\\ 9F A�gllk0 I certify that I have determined through field inspections and ..,.•. t4 review of Municipal records that the above systems are in //4fiP• •• `� -9��� i conformance with MOA COSA guidelines in effect on this date. *: 4911-1 1\ •.* I Engineer's Printed Name Benjamin Schiller, PE • • • • ....: 0 Date 1/21/19 r Benjatriry/Schiller : . j � • # (4% C1/21/19E 12592 ..<47:1' •`( 47 +� f9J � �/ COSA brown sheet 10-10-12.doc Wheaton Water Well, Inc. 1190 N. Wasilla-Fishhook Road Wasilla, AK 99654 (907)376-2041 Name: Troy Davis Homes Inc Address: 1689 Knik Goose Bay Road, Suite 400 City: Wasilla State: AK Zip Code: 99654 Well Site: Denaly Estates Lot/Block: 2/2 Additional: 25322 McIntyre, Eagle River Well Depth: 143 ft. From: To: Formation: 0 9 stick up,silt, gravel Below Ground: 141 ft. 9 16 wet silt,brown Above Ground: 2 ft. 16 47 silt&gravel,grey, dry 47 70 silt,dry,hard Gal/Min: 20 70 134 soft sticky silt Static Level: 0 ft. 134 141 soft silt,gravel 141 143 gravel,sand,water Casing: 143 ft.ft. of 6 in. x .25 in. steel Liner Pipe: none Screened: none Perforated: none Grouted: Bentonite Depth: 20 ft. + Develop. Method: Air Use of Well: Residential Drilling Method: Rotary ;t,-► Lti QUALITY TESTING Misc: none `of tvirm lle9 Co1/100flt Nitratt36_017 mi,/•- ' Arseni:.. P us2nL Other: none The well was pumped 5'off the bottom with 100%draw down for 2 hours and recovered at 20 gpm. Date Drilled: Ben Mattson Driller: 8/23/2018 Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Elmore Road • P.O. Box 196650 Mark Begich Anchorage, AK 99507 Mayor www.muni.org/onsite (907)343-7904 Pump Installation Log Well Drilling Permit Number: SW Date of Issue: Parcel Identification Number: Legal Description Property Owner Name & Address: LOT 2,BLOCK 2 DENALY ESTATES TROY DAVIS HOMES 1689 KNIK GOOSE BAY ROAD SUITE 400 WASILLA,AK 99654 Pump Installation Date: NA Pump Intake Depth Below Top of Well Casing:NA feet Pump Manufacturer's Name: NA Pump Model: NA Pump Size NA hp Pitless Adapter Burial Depth: NA feet Pitless Adapter Manufacturer's Name: NA Pitless Adapter Installer: NEC CONSTRUCTION Well Disinfected Upon Completion? ® Yes ❑No Method of Disinfection: RECIRCULATION Comments: JET PUMP INSTALLED IN HOUSE.NO PUMP IN WELL Pump Installer Name: FORM COMPLETED BY WHEATON WATER WELL INC 1190 N.WASILLA FISHHOOK RD WASILLA,AK.99654 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. McINTYRE ROAD 4- — — \ 395.0 a — 1 T \ 1 1 `15'TkE EASEMENT • -- .:.....I '1g 1 \ INT 0I 10'IRE EASEMENTS HOUSE DETAIL Scale: 1" w 30' Lot 1 PORCN CO 4 1.•rtg1 TBM-TOP OF 5/8"REDAR ° a.380.85 o•`Z' / N N o° .i / \ GP�'C' Mt E 2 a \ 3 / / \ AO' SSO 6 WELL / 1 RE5IOENC 1 // 1 .p o • / W / // Lot 3, T1 ( i N \ \ ? / \= 33.1' - / 3771, \ 110 \ / Lot 25 00SE- NJ7\ SEED 4. d+ _ —r 372.3 �. X70.8 J70.9 -a• 2 e.,1 / 3 // \ / SEPnC \ // PIPES \ \ °j CLEARING LIMI'SJ \ �/ Lot 24 Lot 2 20'ORNNAOE EASEMENT 72.502 s.f. \ \ `_ \ //� \ / \ / N 65.1.,. \ 25 5 75?5 327.62 \\ Lot 23 EAGLE RIVER GREENBELT PLOT PLAN __ AS BUILT X SCALE 1" - 50' GRID _ NW 0362— Project No. 18-276/55 pp'' 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 LangOc Associates, t inc. (907) 522-6476 Phone (907) 522-4625 Fax ..§4'.oOOF A\�\�1 Professional Land Surveyors kenOiongsurvey.com 0,,,,,c.:„._ C9 JonathanOlongsurvsy.com oQS/r 1. I hereby certify that I have surveyed the following described properly: Lot 2, Block 2, DENALY ESTATES SUBD. (Plot No. 2018-29) 0* • 491 1, Anchorage Recording District, Alaska, and that the Improvements situated thereon are g , within the properly lines and do not encroach onto the property adjacent thereto, that j no Improvements on the property lying adjacent thereto encroach on the surveyed KEN •: O premises and that there ore no roadways, transmission lines or other visible easements on said property except as Indicated hereon. l(►'} ti O [s ,;?,t1 ti T 2v '•'-5202••' Dated this the ;Z Day of ew�+nr`•-�' —Sq at Anchorage, Alaska Q a,�,,� o 0 It Is the responsibility of the owner to determine the existence of any easements. 4�40�0. covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963