HomeMy WebLinkAboutTHE CASCADES BLK 1 LT 2 Onsite File The Cascades Block 1 Lot 2 #078 - 321 - 02 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://m,vw.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP201018 Work Type: Septic Upgrade Tax Code Number: 07832102000 Site Legal Address: THE CASCADES BLK 1 LT 2 G:0958 Site Mailing Address: 2500 WEST RIVER DR, Eagle River Owner: BLOCKER DARELL LYNN & ELAINE C Design Engineer: FORGE ENGINEERING This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank 0 Privy Effective Date Expiration Date Lot Size in Sq Ft: Total Bedrooms: 212112020 2/20/2021 103032 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (2417). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: Prior to final inspection report approval, slope stabilization of the drainfield mound and adequate site drainage away from the house shall be confirmed by the department. Received By: Issued By: Date: - -� Date: of Anch®ra2e P.O. Box 196650 ® 4700 Elmore Road Anchorage. Alaska 99519-6650 ® (907) 343-7904 ® Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Department On -Site Water and Wastewater Section wcnr n ;a n � 3yy H lig' 1)epartmcut * * * * VARIANCE/WAIVER REVIEW * * * * Waiver#: OSV201006 COSA#: Permit#:OSP201018 PID#: 078-321-02 Legal Description: The Cascades Block 1 Lot 2 Engineer: Forge Engineering Applicant: Darell & Elaine Blocker Your request for a waiver of the 3 -to -1 side slopes on the mound over the absorption field has been approved. The approved mound side slope is maximum 2 -to -1. See engineer's waiver request and design drawings for justifications. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all code requirements be met or another approval from this department. ............................................... ■ ............................. ■ t Waiver is Granted: X /�� Waiver is not Granted: Municipali Date: �C �� A r v N� • ed �y: L, 4 of Anch®ra2e P.O. Box 196650 ® 4700 Elmore Road Anchorage. Alaska 99519-6650 ® (907) 343-7904 ® Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Department On -Site Water and Wastewater Section wcnr n ;a n � 3yy H lig' 1)epartmcut * * * * VARIANCE/WAIVER REVIEW * * * * Waiver#: OSV201006 COSA#: Permit#:OSP201018 PID#: 078-321-02 Legal Description: The Cascades Block 1 Lot 2 Engineer: Forge Engineering Applicant: Darell & Elaine Blocker Your request for a waiver of the 3 -to -1 side slopes on the mound over the absorption field has been approved. The approved mound side slope is maximum 2 -to -1. See engineer's waiver request and design drawings for justifications. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all code requirements be met or another approval from this department. ............................................... ■ ............................. ■ t Waiver is Granted: X /�� Waiver is not Granted: Date: �C �� A r v N� • ed �y: L, 4 Name of Reviewer .............................................................................. t **** VARIAN C E/WAIVER REVIEW **** MUNICIPALITY OF ANCHORAGE Community Development Department m Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWERANELL PERMIT APPLICATION Parcel I.D. 078-321-02 Property owner(s) Darryl and Elaine Blocker Day phone 310-2501 Mailing address 12110 Business Blvd Suite 6, Eagle River, AK 99577 Site address 2500 West River Drive Legal description (Sub'd., Block & Lot) The Cascades, Block 1 Lot 2 Legal description (Township, Range & Section) Lot Size 103,032 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank ElUpgrade ❑X Duplex (D) ❑ Holding Tank ElRenewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: 2:1 Side slopes on the mound Distance: I certify that the above information is correct. I further certify that this is. in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. os C Permit App_-'-:..�.�c Waiver Fees: OZZ5 Date of Payment: g16l;Z®P-® Receipt Number: Nq'22b Waiver No. GSV*261001V February 12, 2020 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 2/12/20 Subject: The Cascades Block 1 Lot 2 - Septic System Design Dear On-Site Services Engineer: The owner of the above lot called us because their maintenance report indicated water was flowing back into the Advantex system from the trench. Our subsequent investigation revealed that the trench was completely full. We dug a test hole and found, after monitoring the water, that groundwater had risen to within 2.5’ of the original grade. This is a rise of nearly 6’ from our original monitored levels. After discussions with the home builder and contractor, we are proposing to rebuild the trench in the same spot, raising it to 3’ above the measured groundwater level, due to the September reading. The location of the trench will not change, and while the ground slope approaches 25%, the areas immediately downslope are also mostly under 25% and meet the requirements of section 15.65.210.B.1.e of the code. The existing trench will be excavated, and Type II gravel will be filled in as ERS. Above that, 2’ of filter sand will be placed under the bottom of the new 5-wide trench. With the new height, we are requesting a waiver to allow for 2:1 side slopes for the mound. With the height of the fill slope being about 3.5’, the 3:1 slopes will extend approximately 56’, while the house is only 20’ away. A 2:1 side slope will extend 18.9’. The slopes will be covered with topsoil and seeded. The soils drain quickly and effluent will migrate downward faster than it will spread laterally. An impermeable barrier such as Visqueen will be installed to prevent lateral downhill movement and daylighting by the effluent. Storm water drainage will not impact this septic system. The new trench will be constructed parallel to the slope. The proposed well is shown, and adjacent properties are undeveloped. The new system will be a minimum of 50’ from all private wells and surface water, and more than 10’ from the subsurface drain recently constructed to control groundwater. Please refer to the attached test hole log along with plan and profile sheets for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201018, Rebecca Carroll, 02/21/20 31 .6%2 2.9% 22.8% 28.2%24.1%10.01820.01830.01 8 4 0 . 0 1850.01860.01870.018 0 6 . 018 08.01812.01814.01816.01818.01822.01824.01826.01828.01832.01834.01836.01 8 3 8 . 0 1842.01844.01846.01848.01852.01854.01856.01858.01862.01864.0 1 8 6 6 . 0 1868.01872.0874.076.010050 0 FEET 1"=50' REMOVE EXISTING TRENCH BUILD NEW 30' LONG x 5' WIDE x 0.5' EFF DEPTH ABSORPTION TRENCH 4-BDRM HOME EXISTING WELL EXISTING 1500-GAL FAP ADVANTEX TREATMENT TANK w/ AX-20 POD CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT PV - PUMP VAULT MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE MT1 A B C Feb 12, 2020 LEGEND TH#3 WE S T RIVER D R I V E THE CASCADES B1 L2 - 2500 WEST RIVER DR 15' T&E EASEMENT PERC #2 ALTERNATE SITE SUBSURFACE DRAIN EXCAVATE AND RE-ROUTE IF ALTERNATE SITE IS BUILT MH2 PV FCO SUBSURFACE DRAIN SLOPES > 25% SLOPES > 46% MT2 MH1 CO PROTECTIVE BOULDER BARRIER D PUMP VAULT GRADE MOUND TO SHED WATER RUNOFF TOWARD POINT C Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201018, Rebecca Carroll, 02/21/20 THE CASCADES BLOCK 1 LOT 2 DESIGN FACTORS: SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: 21.8 MIN/IN APPLICATION RATE: 4 GPD/SF 5' WIDE TRENCH SYSTEM 1500-GAL ADVANTEX TREATMENT TANK AX-20 VAULT AND PUMP VAULT TYPICAL 5-WIDE TRENCH SECTION (NO SCALE) 1" PERFORATED PVC (HOLES DOWN) w/ 30 x 3 16 " DIAMETER HOLES PER LATERAL @ 1.3' O.C. DRAINFIELD ROCK 5' 6" Feb 12, 2020 NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY BOTTOM OF TRENCH: 0.5' ABOVE ORIGINAL GRADE GRADE FLOW LINE ELEVATION: 1.0' ABOVE ORIGINAL GRADE GRADE TOP OF TRENCH: 2.5' ABOVE ORIGINAL GRADE 600 GPD / 4 GPD/SF / 5' WIDE * 1.0 REDUCTION = 30.0 LF TRENCH REQUIRED INSULATION 2'-6" 2:1 MAX SLOPE PROVIDE TOPSOIL AND EROSION CONTROL VEGETATION DRAWN @ 25% SLOPE 2' MOA-APPROVED SAND TYPE II FILL BOTTOM OF EXISTING TRENCH 6" REMOVE ORGANICS BENEATH FILL IMPERMEABLE BARRIER (VISQUEEN OR EQUAL) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201018, Rebecca Carroll, 02/21/20 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 3 SLOPE SLOPE SITE PLAN See Site Plan DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) CASCADES B1 L2 4/10/2018 J. Millette Development Services Department 4700 Elmore Road Anchorage, AK 99519-6650 Municipality of Anchorage DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH OF WATER AFTER MONITORING: IF YES @ WHAT DEPTH? YES 8' 2.5' 0.5 6 3 4 078-321-02 TROY DAVIS Professional Engineers Stamp: Jan 28, 2020 19:00/19:03 4/10 1 2 3 4 5 6 3:10 619:04/19:07 19:08/19:11 19:12/19:15 19:16/19:19 19:21/19:24 1' OB WELL-GRADED GRAVEL W/ SILT & SAND (GW-GM) 9/23/19 3:05 5 4 16 - 11 4 16 6 3:11 6 3:09 6 3:11 6 3:12 6 BOH 5 4 16 - 11 4 16 5 4 16 - 11 4 16 5 4 16 - 11 4 16 5 4 16 - 11 4 16 5 4 16 - 11 4 16 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201018, Rebecca Carroll, 02/21/20 Municipality of Anchorage uBM,TT� On-Site Water and Wastewater Program• (907) 343-790 Page 3 ON-SITE WASTEWATER INSPECTION REPO FEB 2 b 2019 Permit Number: OSP181135 PID Number: 078-321-02 Dwelling: ❑■ Single Family (SF) ❑ Duplex(D) ❑ Multiple(SF and/or D) Project: 0 New ❑ Upgrade Name: ABSORPTION FIELD Troy Davis Homes Address ❑ Deep Trench 0 Shallow Trench ❑ Bed ❑ Mound 1689 Knik Goose Bay Rd 400 Wasilla, AK 99654 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 310-2501 4 4.0 GPD/SF 3.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 2.0 Ft. 1.0 Ft. The Cascades 1 2 Fill added above original grade Gravel length Township Range Section 1.2 Ft. 27 Ft. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES 5 Ft. Ft. To Septic Absorption i Holding Sewer Total absorption area Number of trenches Dist.between trenches From Tank Field Lift Station Tank Line 153 Ft2 1 Ft. Well >100' >100' N/A ' N/A >25' TANK ❑Septic ❑S.T.E.P. ❑Holding ❑■ Other Manufacturer Capacity Surface Water >100' >100' N/A N/A Orenco/FAP 1500 Gal. Material Number of compartments Lot Line >10' >10' N/A N/ANA Fiberglass 2 Foundation >10' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Orenco/Anchorage Tank 100 Gal. Pump on level at Pump off level at High water alarm at Remarks Trench is insulated 13 in. 25 in. 11 in. Pump make and model Electrical Inspections performed by PF2005 Commercial Electric PIPE MATERIAL House to tank D3034Tank to HDPE drainfield Installer Northern Excavation Drainfield D1785 CO/MT D3034 Inspector J. Millette BENCH MARK (Assumed elevation) 100 ft Inspection 1" 8/20/18 2nd 8/21/18 Location and description 3`d 4th Top block of foundation on west wall. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp _imosiihusii pi.. Conditional Approval: Date +-•P7E,O....* .Ar...; • :6 v1 a4 "• .1* • a 49th �� t fa 0.R..r.....N.... ... .N.N.5,(I..i THE CASCADES B1 L2 - 2500 WEST RIVER DR PERMIT # OSP181135 PID # 078-321-02 \\ \\ \ \ \iPR\OTEVE\ ` \ \:, 15'TREE EASEMENT \\ \ s \ t ///i \ \ 1500-GAL FAP AOVANTEX K \_, �, TREATMENT Tb1NK w/AX-201POD o` \ -u p,H2�• o•�` BOULDER• \ \ i �/� ` ,, '{?UMF' AUL :V�\ � 'MH1 8ARtRI R \\ '\ ` . \ \ \ .1.2 `• FCO '\ CO, t ' • \\ \ , "S� \ t SUBSURFACE DRAIN X ` /I \ \ \ `` � \ \ . 22 a4, ' '\\,` '-BDRM HOM , \ '''--, \ \ ' ` /.• \ \ \ % \\;\t\ \ \ \ • \ MT1 \' t \` s ", \ \. \TH#3 tkT2\`. `\• L \ �•• ' / • ; `. , \ +p `. \ \ \.a \ \ ••�.. `,•• ` • .':�c�b •\ \ , \ I :\ , \ , �c9\,.gyp _\ `\ •�� T. PERC#'L , �\\\ ,� �• •icy ,o° ��z i; 1 \ 7{'LONG x 5'Wide x'1;EFF. \ \ \�\ _ • / o I� \ s \ \ pEPtk�A$SORPZION` REI'JCI-f'. 1 ! \ \ \ 1 ,EXISTING 24,__`\1 \ . f \ t N. , \ ,\ ••• \ \\ \ .50d,WaL F��4DIUS 1 I 1 \ '\ E, t . \ 1 ' 'ALTERNATE SI iE'. X` \' \ \ U'`,, o ` \ ` \ I1 \ ` ' 1 i \ \\ \ j \\ • 'GEX'1TOFF1LL \ i 1 ` \ \ \ \ \ ` , ` \•\ ` \ `o l 1 1 ` \ \ ' 1\ `\\ . ` \ \\ \ , \,3%,; 1 ` ,1 \ 1 \ ' \\LOT \\ \.\ ``� \\SuB Ek�RAI�I \ • 1 1\0 4T '�I I I I \ ,1 \ \ 1,� I I 1 LOT 1 \'`\ \\ \ l \• \ ` t \ o, i 1 • N \ \ � II \ \ \ •\ \ \ \ iaa , 'i 11 \ \ / \ \ t, \ \ ,, , i \\ \ , $ , \ 7 ' , \ \t 1 4 �� a TO p \ .y \ , , 1, \ \ \ t `., ' 1 t . o ebb, 'a \ t \ ji ilifitGE N41Nt Et IN4 \. ( ` \ \ ♦,\ \\\ ,\ , `\ 1 tl :1 ''0. to `. , S 1 • \ 4 , 1 \ } t 1 0 A B C D 444 OF ',��'• FCO 12.3 3.5 .•.-\L- .••N•••: q th CO • 17.4 13.7 LEGEND ,!`t,��P'.•• ••� MH1 19.8 14.0 CO-CLEANOUT tir 4 .• �c *•j MH2 28.7 17.9 2C0-DOUBLE CLEANOUT 49th _ .!* PV - 27.0 13.9 FCO-FOUNDATION CLEANOUT • G r MT1 23.4 59.1 PV-PUMP VAULT Yt.�Mt.ttNtYNYtNttYYN.Y.YYtN ' 'MICHAEL E. ANDERSON Zt~ MT2 34.2 34.3 %� MH-MANHOLE itr-a,yt No. CE-4381 4.4 �ar 0 50 100 MT-MONITORING TUBE 0t�F'% 2/20/1'...e.. 4' SLOPES>25% 41, FEET SV SEPTIC VENT ++i� ES5�0\r'i, 1"=50' SLOPES>46% TH-TEST HOLE THE CASCADES BLOCK 1 LOT 2 PERMIT # OSP181135 PID # 078-321-02 0 LL. 10 = 88.8 = 2 AX-20 POD ANC MANHOLES I— � 1 d D 85.0 1500 GAL n FAP TANK U 80.5 2" INSULATION 101.6 FINISH GRADE I- 100.4 ORIGINAL GRADE 2 ���!��l��l����!:��������!��l��l�����✓���!��!��!����������1�����������!��!��!��l��l��!��1��!��!��- •��-�!��!��!�X�l��<a - .-_•••4=a- =(n=n=u=n=n=•.=n=n=u=n=a=u=u=a=u=u=u=u=u=u=u=u=u=n=u=u=a=n=n=n-u-n_u-u-a-n-n-u • o n n n-a-n-u-i _f.Jlr, yj`.51.\- ..-},` = .�.3 �'l.Y.i{..:N3� L��?�1:4a.Y�.'I- ,rF�if 98.4 —� � .: v.. -;,Y,� fuf > �•Kt.y^5 :9 v: �. %i^ t''?. ':q r 98.4 4 .�=�L':. .%ti'� � ,s.. .ar '.,.,}- tT -�.�i.:'�;f�.v i..% "; r.; t; 97.4 27' 97.4 —� 93.9 GROUNDWATER ENCOUNTERED 4/25/18 90.4 H visswa it II la • W •'49th `• 0 ;..1,1* Y....H yam •- • S MICHAEL E. ANDERSON IT gy PROFILE AS-BUILT T..,. O. 8t r•�== GE (NO SCALE) • re..,,220/19CE-a3............... .... .44 Nei 401iFsEsSaSs\ E MGIwf[4 iNG Wheaton Water Well, Inc. 1190 N. Wasilla-Fishhook Road Wasilla, AK 99654 (907)376-2041 Name: Troy Davis Homes Inc. ] Address: 1689 Knik Goose Bay Road, Suite 400 City: Wasilla State: AK Zip Code: 99654 Well Site: The Cascades Lot/Block: 2/1 Additional: 2500 West River Rd. Eagle River Well Depth: S7, From: To: Formation: 0 2 Stick up Below Ground: 55' 2 4 Fill Above Ground: 2 ft. 4 12 Wet Silt&Gravel Gal/Min: 1212 26 Silt,Cobble,Gravel 26 31 Boulder Static Level: 16' 31 34 Gravel,Silt 34 37 Boulder Casing: 57'ft. of 6 in. x .25 in. steel 37 48 Gravel,Silt 48 57 Gravel,Water Liner Pipe: N/A Screened: N/A Perforated: N/A Grouted: Bentonite Depth: 20' plus Develop. Method: Air Use of Well: Residential Drilling Method: Rotary Misc: N/A Other: N/A WATER QUALITY TESTING Coliform Al eP Coi/100mL Nitrates . 0 mg/L Arsenic 2 , 50 ug/L Date Drilled: 8/24/2018 Driller: Ben Mattson MUNICIPALITY OF ANCHORAGE Development Services Department - Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: Date of Issue: - - Parcel Identification Number: - - Legal Description Block Lot Property Owner Name&Address: The Cascades 1 2 Troy Davis Homes 1689 Knik Goose Bay Rd. Ste. 400 Wasilla, AK. 99654 Pump Installation Date: 09 -13 -2018 Pump Intake Depth Below Top of Well Casing: 37 feet Pump Manufacturer's Name: MYERS Pump Model: 2NFL52-12-P4 Pump Size: 1/2 hp Pitless Adapter Burial Depth: 13 feet Pitless Adapter Manufacturer's Name: CAMPBELL Pitless Adapter Installer: NEC CONST. Well Disinfected Upon Completion? LN Yes 0 No Method of Disinfection: RECIRC Comments: Pump Installer Name: BRIAN WI LLE Company: WHEATON WATER WELL INC Mailing Address: 1190 N. WASILLA FISHHOOK RD City: WASILLA State: AK Zip: 99654 Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation. /`�OAllfy MUNICIPALITY OF ANCHORAGE On-Site Water&Wastewater Program PO Box 196650 4700 Elmore Road • Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 httpa/www.muni.org/onsite Mil boli I)vpartinttiI 4'YCHoRAo• On-Site Water & Wastewater System Permit Permit Number: OSP181135 Effective Date: 8/9/2018 Work Type: WellSeptic Initial Expiration Date: 8/9/2019 Tax Code Number: 07832102000 Site Legal Address: THE CASCADES BLK 1 LT 2 G:0958 Site Mailing Address: 2500 WEST RIVER DR, Eagle River Owner: SNS HOLDINGS LLC Lot Size in Sq Ft: 103032 Design Engineer: FORGE ENGINEERING Total Bedrooms: 4 This permit is for the construction of: Q Disposal Field El Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: ,6/ /.1, —M Date: e/q/is' Issued By: l,( err Date: g/q/9 gPlitikiS MUNICIPALITY OF ANCHORAGE • Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On-Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 078-321-02 Property owner(s) Troy Davis Homes, Inc. Day phone 310-2501 Mailing address 1689 Goose Bay Road #400 Wasilla, AK 99654 Site address 24826 Miltherrie Chugiak, AK 99657 Legal description (Sub'd., Block & Lot) The Cascades, Block 1 Lot 2 Legal description (Township, Range & Section) Lot Size 103,032 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (I1 all that apply) Absorption Field X Initial ❑X Single Family (SF) X (w/wo ADU) Septic Tank X Upgrade ❑ Duplex (D) (l Holding Tank ❑ Renewal Multiple Dwellings ❑ Privy [J (SF and/or D) Private Well x❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: ?ELI Waiver Fees: Date of Payment: 610!tg Date of Payment: Receipt Number: 04MNA Receipt Number: Permit No. 033P l Y 105- Waiver No. Permit App_.:-.- :1.�c PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) August 7, 2018 MOA Development Services Dept- On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: The Cascades Block 1 Lot 2 - Septic System Design Dear On-Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home and the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes moderately and evenly from the back of the lot toward the road. Slopes range from 20-30%. There are very few spots where slopes approach 40-50%, just small dips in the ground only a few feet long. Drainage arrows are shown on the site plan showing the grade and direction of flow. Storm water drainage will not impact this septic system. The new trench will be constructed parallel to the slope. A Category III Advantex Treatment System will be constructed on the lot. This system allows for reduction in both vertical and horizontal separation from groundwater and excessive slopes. The trench will be built in an area where the slopes are less than 25%, along with the alternate site. The areas immediately downslope are also mostly under 25% and meet the requirements of section 15.65.210.B.1.e of the code. The percolation rate measured at TH3 was under 1 min/in. The laboratory analysis designated the soils as GW-GM, and not GW. Additionally, soils tests and percolation tests on other lots in the area demonstrate that this type of loose soil is not commonly found here. This appears to be a relatively small pocket of this type of gravelly soil, and we are confident that, according to the exception at 15.65.210.D.1.c, other soil layers exist that will protect the aquifer from contamination. A subdrain recently excavated near the test hole did not indicate any areas of subsurface material which would absorb water at less than 1 minute per inch. The secondary perk test done approximately 50’ away showed the same soil type at approximately the same level. The consistency over this area makes us confident that the alternate site is adequate, although it is not Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181135, Deb Wockenfuss, 08/09/18 within 30’ of the test hole. We request that this alternate site be approved for this purpose. If required, a test hole can be dug at a future time to verify groundwater levels. The subdivision file mentions a spring on the lot, draining along the northwest property line. A site visit on Thursday, July 26 for the purpose of investigating this did not reveal evidence of a spring or regular running surface water on the lot, and particular attention was shown to the northwest property line. Additional groundwater levels were taken, to compare with subdivision records and to check the effectiveness of the curtain drain. The test hole was now dry down to the bottom. The proposed well is shown, and adjacent properties are undeveloped. The new system will be a minimum of 50’ from all private wells and surface water, and more than 10’ from the subsurface drain recently constructed to control groundwater. Please refer to the attached test hole logs, soils lab analysis, plan and profile sheets for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE 8/7/18 3 1 .6%22 .9 %21.2% 22.8% 28 .2%24.1%.0 1820.01830.01 8 4 0 . 0 1850.01860.01870.018 0 6 . 01808.01812.01814.01816.01818.01822.01824.01826.01828.01832.01834.01836.01 8 3 8 . 0 1842.01844.01846.01848.01852.01854.01856.01858.01862.01864.0 1 8 6 6 . 0 1868.01872.01874.01876.010050 0 FEET 1"=50' 27' LONG x 5' WIDE x 1' EFF. DEPTH ABSORPTION TRENCH 4-BDRM HOME PROPOSED WELL 1500-GAL FAP ADVANTEX TREATMENT TANK w/AX-20 POD AND PUMP VAULT NO SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT PV - PUMP VAULT MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE MT Aug 09, 2018 NOTE: LEGEND TH#3 WE S T RIVER DR I V E THE CASCADES B1 L2 - NHN WEST RIVER DR 15' T&E EASEMENT PERC #2 ALTERNATE SITE SUBSURFACE DRAIN PV MH MH FCO ABSORPTION TRENCH MUST BE CONSTRUCTED A MINIMUM OF 10' FROM THE SUBSURFACE DRAIN. DRAIN OUTFALL MUST BE A MINIMUM OF 50' FROM ALL SEGMENTS OF THE SEPTIC SYSTEM. NOTE: SUBSURFACE DRAIN SLOPES > 25% SLOPES > 46% MT EXTENT OF FILL Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181135, Deb Wockenfuss, 08/09/18 SYSTEM REQUIREMENTS:DESIGN FACTORS: THE CASCADES BLOCK 1 LOT 2 DRAINFIELD ROCK 600 GPD PEAK FLOW PERK RATE: 21.8 MIN/IN APPLICATION RATE: 4 GPD/SF TYPICAL 5-WIDE TRENCH SECTION (NO SCALE) 5' WIDE TRENCH SYSTEM 1500-GAL ADVANTEX TREATMENT TANK AX-20 VAULT AND PUMP VAULT 1" PERFORATED PVC (HOLES DOWN) w/ 30 x 3 16" DIAMETER HOLES PER LATERAL @ 1.3' O.C. INSULATION 5' 6" 1' 2' Aug 07, 2018 NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY BOTTOM OF TRENCH: 3' BELOW GRADE FLOW LINE ELEVATION: 2.0' BELOW GRADE TOP OF TRENCH: 0.5' ABOVE GRADE 600 GPD / 4 GPD/SF / 5' WIDE * .88 REDUCTION = 26.3 LF TRENCH REQUIRED (27 LF SPECIFIED) 3:1 MAX SLOPE PROVIDE TOPSOIL AND REVEGETATE DRAWN @ 25% SLOPE ORGANICS Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181135, Deb Wockenfuss, 08/09/18 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: PERC #2 SLOPE SLOPE SITE PLAN See Site Plan DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) CASCADES B1 L2 4/10/2018 J. Millette Development Services Department 4700 Elmore Road Anchorage, AK 99519-6650 Municipality of Anchorage DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH OF WATER AFTER MONITORING: IF YES @ WHAT DEPTH? 21.8 6 3 4 078-321-02 TROY DAVIS Professional Engineers Stamp: Jul 24, 2018 19:15 4/10 1 2 3 4 5 6 30 1 4 1619:45 PERKED IN SILTY GRAVEL SMALL AMOUNTS OF SAND 4 12 16 PERK HOLE PRESOAKED PRIOR TO TESTING. PERK TEST ONLY, NO GROUNDWATER MONITORING 6 19:46 30 1 6 1620:16 4 12 16 6 2 16 20:17 3020:47 4 12 16 6 2 16 1 6 16 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181135, Deb Wockenfuss, 08/09/18 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 3 SLOPE SLOPE SITE PLAN See Site Plan DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) CASCADES B1 L2 4/10/2018 J. Millette Development Services Department 4700 Elmore Road Anchorage, AK 99519-6650 Municipality of Anchorage DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH OF WATER AFTER MONITORING: IF YES @ WHAT DEPTH? YES 8' 6.5' 0.5 6 3 4 078-321-02 TROY DAVIS Professional Engineers Stamp: Jul 24, 2018 19:00/19:03 4/10 1 2 3 4 5 6 3:10 619:04/19:07 19:08/19:11 19:12/19:15 19:16/19:19 19:21/19:24 1' OB WELL-GRADED GRAVEL W/ SILT & SAND (GW-GM) 4/25/18 3:05 5 4 16 - 11 4 16 6 3:11 6 3:09 6 3:11 6 3:12 6 BOH 5 4 16 - 11 4 16 5 4 16 - 11 4 16 5 4 16 - 11 4 16 5 4 16 - 11 4 16 5 4 16 - 11 4 16 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181135, Deb Wockenfuss, 08/09/18 ............... . l raior�':::'I`est� :::.:: ..o#ec mica r ine .rin ::..::. �n . r r o t tion :: :'Cons u� � ::�o o.r n r ie s:::.''ler 1. WIS. : PROJECT CLIENT: PROJECT NAME: PROJECT .: SAMPLE LOC.: NUWER/ DEPTH: Li t T3 I. DATERECEIVED: TESTED Y: REVIEWED Y: 100 90 80 70 60 50 40 30 20 10 0 145 140 u 135 130 125 Forge Engineerhig Cascades 4914-1 Lot TH3 Well -grade d gravel iv/ salt aad saiid 41.0/201$ J PC % GRAVEL 46.8 % SAND 43.5 }- % SILT/CLAY 9.7 % MOIST. CONTENTrl LSCS GW -GM USA.0 E FC N/A % PASS. 0.02 mm ITA % PASS. 0.002 mm N/A UNIFORMITY " C EFFICIENT" C. 90.6 COEFFICIENT OF GRADATION C. 1.1 ASTM D I (uneotTe t NIA ASTM D47I (corrected) N/A ,OPTIMUM MOIST. CONTENT. (corrected) N/A PARTICLE SIZE ANALYSIS ASTM D422 C 13 6 U_& SIEVF. OFF.NrKCj IN INCIES 1 U.S. S[EVE NUMBERS HYDROMETER 100 10 1 0.1 0.01 0.001 GRAIN SIZE (m GRAVEL SAID COD13LES SILT or CLAY I~oarse Pane Coarse lec�iurrr Fine MOISTURE -DENSITY RELATINSP ASTM D 1 120 w i i r1 r I r 11 k 0 2 4 6 8 10 12 14 1 MOISTURE C TE T% SIEVE ANALYSIS RE, SULT" SIEVE SIZE (mrn) SIEVE SIZE (U.S.) TOTAL Ifo SPECIFICATION PASSING ° PASSING) N/A (ASTM D2434 152.40 611 76.20 311 38.10 1.5" too 19.00 3141" 0 12.70 1/2$# 9.50 /8" 67 4.75 #4 53 2.00 #I0 41 0.85 #20 31 0.43 #40 24 0.25 #0 2 0.15 #100 1 0.075 #200 9.7 HYDROMETER RESULT ELAPSED DIAMETER TOTAL % TIME (NffN) (Dim) PASSING 0 0.5 4 15 30 0 250 1440 HYDRAULIC COND. N/A (ASTM D2434 DEGRADATION NI.. (ATM T-313) PLASTICITY INDEX N STM 4318 The testing services reported herein have been performed to recognized industry standards, unless otherwise noted. No other warranty is in.ade. Should etz eerie interpretation or opinion be required, I E„TFT will provide upon written request. 11301 Olive Lan • Anchorage, A las a 99515 - Phom: 907-344-5934 - `air: 907- 7-344-5993 • witpuy. n --t t, com MUNICIPALITY OF ANCHORAGE I • ,ft Development Services Department "' ` Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On-Site Systems Approval a Parcel I.D. 078-321-02 Expiration Date: — 7 1. GENERAL INFORMATION Complete legal description The Cascades Block 1 Lot 2 Location (site address) 2500 West River Drive Current property owner(s) Troy Davis Homes Day phone 907-357-9394 Mailing address 1689 S. Knik Goose Bay Road #400, Wasilla, AK 99654 Real estate agent Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well Private Septic Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ 1 -o a-o Waiver Fee $ Date of Payment Z/Z �'/ j q Date of Payment Receipt Number C-gg 3 a p Receipt Number COSA# OC-- / q / 2c'/ Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Forge Engineering Phone 907-522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage AK 99503 Engineer's Printed Name Michael E. Anderson, P.E. Date 2/20/19 .... • 49th . .h 6. DSD SIGNATURE ; y,�, � � • System #1 Approved for (1 bedrooms ,�, • • MICHAEL E. ANDERSON •��� •• No. CE-4381 � _• System #2 Approved for bedrooms •./•••. 2�zo�ts ...•'QC,': Disapproved �t��hI;i S \C�••� Conditional approval for bedrooms, with the following stipulations: 01 3 ON-SITE 6, WATER AND R' WASTEWATER o PROGRAM Original Certificate Date: ^ 7 - The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checkl,st blue sheet COSA Checklist Legal Description: The Cascades Block 1 Lot 2 Parcel ID: 078-321-02 If more than 1 septic system on lot: COSA Checklist# of Structure served by this system A. WELL DATA ■❑Well log is filed with Onsite (or attached) Well production at time of test 12 gpm Date drilled 8/24/18 Water storage tank volume N/A gallons Total depth 57 ft Well disinfected for coliform test? El Yes ❑� No Cased to 57 ft ❑j Coliform bacteria is Negative ■❑ Sanitary seal is functioning correctly Nitrate .307 mg/L ❑ Nitrate less than MRL (ND) ❑■ Wires are properly protected Arsenic 2.50 ug/L ❑Arsenic less than MRL (ND) Casing height (above ground) 24 in. Collected by Wheaton Water Wells Date of flow test for COSA 8/24/18 Date of Sample 2/22/19 Static water level at beginning of test 16 ft. Comments B. TANK DATA C. LIFT STATION Age of tank(s) 0 years [' Required maintenance completed Tank type/material �°"�" °" Age of lift station years Measured operating fluid level in septic tank New Lift station material ❑� Standpipes/foundation cleanout per record drawing Comments: Date of pumping This is an Advantex System D. ABSORPTION FIELD DATA 5 -Wide Which system tested (date installed) 8/20118 Adequacy test date New ■❑ALL standpipes present per record drawing Results ❑Pass For bedrooms Total measured depth from grade 4.2 ft (max) Fluid depth prior to test in Measured depth to pipe invert from grade ft(min) Water added gal ❑ N/A—pressurized field New depth in ❑■ Monitor tubes go to bottom of effective. If not, state Elapsed time min depth into effective ■❑ Final fluid depth in Code-required soil cover over field ❑ System presoaked Absorption rate gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) date of test) Gallons introduced N/A gallons If yes, enter date Comments/Deficiencies: COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot> 100' Community Sewer Manhole/Cleanout > 100' 0✓ Yes if No ft Q Yes if No ft Neighboring Tank > 100' ❑✓ Yes if No ft Private Sewer/Septic Line>25' M Yes if No ft Absorption Field on Lot > 100' ❑✓ Yes if No ft Holding Tank > 100' 0✓ Yes if No ft Neighboring Absorption Fields > 100' Animal Containment > 50' 0✓ Yes if No ft j Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ✓0 Yes if No ft ❑✓ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations> 10' 0✓ Yes if No ft Surface Water> 100' 0 Yes if No ft Property Line > 5' 0 Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ✓0 Yes if No ft Private Wells> 100' 0 Yes if No ft Water Main > 10' ✓0 Yes if No ft Community Wells> 200' 0 Yes if No ft Water Service Line > 10' 0 Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ❑✓ Yes if No ft If absorption field is under driveway comment below Property Line > 10' 0✓ Yes if No ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells> 100' 0 Yes if No ft Water Service Line> 10' 0✓ Yes if No ft Community Wells> 200' ❑✓ Yes if No ft Surface Water> 100' ✓0 Yes if No ft F. ENGINEER'S COMMENTS ooleari G. ENGINEER'S CERTIFICATION ��•'\V— OF•••4C.g44�/�- I certify that I have determined through field inspections and review s IP�••••• �1 . ••••;Y�.j of Municipal records that the above systems are in conformance with �\ == MOA COSA guidelines in effect on this date. ; 49th ••t — 141 E 1-2c ` MICHAEL E. ANDERSON i 41:: ilj INE �'J, N o. CE-4381 ..�\�,:�1�' 1 • •• •vA 601, 2/20/19 •••••fit,\* COSA Checklist yellow sheet 4 Q• •••••••C 1 •• ` ., MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT,herein the"AGREEMENT"made and entered into as of this 1;11\Day of /\ a,j CIA of 20/' ,by and between e k\ '-042-4 ,herein the"OWNER,"and the Municipality of Anchorage,herein the"MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein,the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System(AWWTS), described as Advantex Treatment System located at(legal description) The Cascades Block 1 Lot 2 2. Maintenance.Repairs and Alterations. (Owner is required to read,understand and initial each section) Ige7,_,d Throughout the term of this Agreement,the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing.treated septic effluent in accordance with the equipment's approval for operation in the Municipality. . It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s),maintenance,adjustment(s),replacement costs,and inspection costs. This //77 includes an annual maintenance fee(typically$400 to$600). .)2jOwner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect andmake any necessary maintenance, repairs or permitted alterations to the system. PIP4P5Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system,which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of 3 ePi..2 Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. ,QV Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. gbj2j>7 Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. i 27/3 Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On-Site Systems Approval. )<J 'Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction,maintenance and repair of the Owner's AWWTS. 2�Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system,or upon transfer of title,and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions,nor in any way affect the validity of the Agreement or any part hereof,or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severabilitv. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 OWNER: rr $ . (signature) Date: / LLL 1 1 /1 1(�/'�0� ; 11k12.— k9—' (print name) STATE OF ALASKA ) )ss. THIRD JUDICIAL DISTRICT ) The foregoin instrument as acknowledged before me this- 14-\day of Hoc c� , 20n , by 1 � Y PUBLI ,FOR�� ASKA Notary Public My Commission expires: �tao ! +` i MEGAN KIRK State of Alaska My Carolinian ExpUea May 23,2022 MUNICIPALITY: By: ( t _ ( (signature) Date: 3 r 7^f (print name) Title: (rev. 05/18/2018) Page 3 of 3 i r— • I I 0 .,, 'C l' '1-' m � 4 \4.f _ Fr'I 4. .• ^t ea, p,0 $,� m •t*45 p� a o_-1 ?n D 1 r— a> o ?" a` 0 z c CO to cn a c, C ni Q N a G. n) • -+ r a 0 v tN 4. A N J• S>. 81 rt Js� 6,1? m N s?• N ti rn n tom ti A rn rn m .a m -o m m �� Z —I rn O rn / /I' N /I// 4'xJ '�,°','�y r*. / / / JS 4,yC .XI 0. ‘1.;'(ij 41t* / e?• a 1 a 07` z / 0 z/ ccs / / / / P / II R / I I (5 / // / z0 / K PLOT PLAN AS BUILT X SCALE 1- - 60' GRID SW 0958 Project No. 18-111/66 Sc 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 LangOC Associates, inc. (907) 522-6476 Phone (907) 522-4625 Fax F Professional Land Surveyors kenOlangsurvey.com !` ..!q,�q�0a jonothanOlangsurvey.com Av• .• s1V I hereby certify that I have surveyed the following described property: ( 49� ¢ LOT 2, BLOCK 1. THE CASCADES SUBDIVISION (PLAT No. 94-128) �.. Anchorage Recording District, Alaska, and that the Improvements situated thereon ore within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed 0 KENNETH premises and that there are no roadways, transmission lines or other visible //��,, easements on said properly except as indicated hereon. `0,%40....; 1 y1 VVU ••''5_5 O2.• Doted this theme_ Day of PYrW t,-,,^-ti' �� of Anchorage, Alaska Qti,ed '..0.0_,- , ��SSK1tW. d It Is the responsibility of the owner to determine the existence of ony easements, � C9 covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963