Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DENALY ESTATES BLK 2 LT 18
Onsite File Densly Estates Block 2 Lot 18 #067 - 062 - 25 :. E- A!LED 'frill ctj/ �0-'cc: A Municipality of Anchorage Community Development Department Page 1 of 2 On-Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907)343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181248 PID Number: 067-062-25 ✓❑ New ❑ Upgrade Name: JAMES & LISA GENTEMANN ABSORPTION FIELD Address ❑ Deep Trench ❑✓ Shallow Trench ❑ Bed ❑ Mound 25422 BLACK PINE CIRCLE ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 3 0.8 GPD/SF 6.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 2.0 Ft. 4.0 Ft. DEANLY ESTATES 2 18 Fill added above original grade Gravel length Township Range Section 0.5 Ft 60.0 Ft. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES 5.OFt. N/A N/A Ft. To Septic Absorption I Holding Sewer Total absorption area Number of trenches Dist.between trenches From Tank Field Lift Station Tank Line 300 Ft2 1 N/A Ft. Welt 130.8 121.2 N/A N/A 51.4 TANK ❑Septic ❑S.T.E.P. ❑Holding ❑Other Manufacturer Capacity Surface Water 100+ 100+ N/A N/A ANCHORAGE TANK 1000Ga1. Material Number of compartments I Lot Line 120.0 83.2 N/A N/A STEEL 2 . NA Foundation 66.1 58.2 N/A � N/A LIFT STATION Manufacturer Capacity Curtain Drain 1 50+ 1 50+ N/A N/A Gal. Pump on level at Pump off level at 'igh water alarm at Remarks _ in in. in. �� Pump make an. .:el Electrical Inspections performed by PIPE MATERIAL House to tank 3034 Tank to 3034 Installer drainfield WHITTERS Drainfietd 3034 CO/MT 3034 Inspector Pannone Engineering Services BENCH MARK (Assumed elevation) 455.0ft Inspection „ Location and description dates: 1 8/28/18 2^d_8/29/18_ 3rd 8/29/18 4th 1/2/2019 BOTTOM TRIM AT HOUSE POINT A COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp roto\mak Conditional Approval: Date ,•`.�, • q �� # t ----- Steven V. �onnorae 0 4¢��cs , CE�8149 �i� s tV• leek, Approved _.._ &milt) Date 47/6//1 It�l�OFESStte0 as Inspection Report_1-1-12.doc PRIMARY DESIGN PARAMETERS WELL (E)/a rl, NO. BEDROOM: 3(450 gpd) i TANK SIZE: 1000g i PERC RATE: 6.9 MPI SOIL RATING: 0.8 GPD/SF AREA ROO: 562.5 SF i.- .\ \ y__ REDUCTION FACTOR: 0.5 _- \ `�\ ` I ADJUSTED ABSORPTION AREA: 281.25 SF - - \ ` SYS. TYPE:WIDE TRENCH 4.0'ED A �✓ MIN LENGTH: 57 LF ----. N. \ \ \ % ` \ Q \ \ \ LOI 18 USED: \ \ \ / 60.OLFx5.0'Wx4.0' E.D., 6.0'TO \ \ \ /i TOTAL AREA: 300.0 SF \ \ DRIVEWAY & HOUSE LOCATION 0 \ DRIVEWAY `` \BASED ON PLOT PLAN NO \ \ AS-BUILT AT THIS TIME N.,... \IA [ \\ --. A \ \ \ LNDEVELOI \ \-._ WELL N \ S3C \ \ \ N INSTALLED 1000G SEPTIC TANK LOT \ \ \ N W/ FC BEFORE AND DCO AFTER // SS \ T1 INSTALLED ABSORPTION FIELD .z \\ - \ \ / F� \ ss\ T2 60LFx5.0'Wx4.0'E.0.,6.0'T.D. \ - �F w/ MTs & COs AT ENDS OF FIELD \ \\ , Cl - DCO ADDECD 2" R.I. ` ` Ti 92.8 70.0 ~ \ \• \ \ r- \ M2 - T2 97.0 76.0 \ \ \ \ \ \` -- _-_-_-'" TH-P. N aeo' DCO 98.9 78.5 \ \� \ \ \-- - N \ \ \ N Cl _ 74.0 70.7 ...N...„/ \W \ \W . RESERVE AREA (MC) \� N Mi 76.8 73.8 \ \ \ \ 6OLFx5.0'Wx4.0'E.D.,6.0'T.D. C2 1 135.4 1 19.4 \ \ . \ a 5 > M2 136.0 121.0 \ \ \ \ \ \ \ \ \ . . - \ \ \ N \ \ h ,- r 0 La w w ma © m O./ U v cit', 5 .2 FILTER FABRIQ .-� co 0 K Q 0 - - O.C.F,C. - -- z 9 ORAIN ROCK 6"ABOVE PIPE INV 9 41 I_ ____..... 0 4-0 GRAIN PIPE O \\\U - 2'R.I 4.0 \`[ F,C.465.5 I - -O.C.465.0--- -'----- '-'- -- :: - �' 1.0 / 1000 g SEPTIC �- , 465.4 TANK 465.2 / 4.0'DRAIN ROCK 463.0 463.Q' PROFILE a SCALE:NTS e f U IS ,6 OAK•CNrOA'CO.7lM,a NOTES: PANNONE ENG SVC, LLC RECORD DRAWING P.O. BOX 102954 ANCHORAGE, AK 99510 '(� 1/8/2019 PHONE (907) 272-8218 FAX (907) 272-8211 �p'•• y Scale , *: , . 6 .4 N %It 1" = 50' • '® \�• P.i.D. NO DENALY ESTATES B2 L18 _ . .��vow . _ _25 JAMES & LISA GENTEMANN •• �e'ven A: }SaflriORe PERMIT 1.N220 DRAWN ACP � 25422 BLACK PINE CIRCLE ,,• i CE 8149, OSP181248 EAGLE RIVER, AK •'so• y Sheet 2 OF 2 Certified Drilling Log DOC CO dba 1biLL&niOAEN WATER WELLS P.O. Box 670269, Chugiak,AK 99567 688-2759 OWNER OF LAND: Midnight Sun Construction Bore Hole Data ADDRESS: Depth LEGAL DESCRIPTION Denaly Estates Block 2 Lot 18 From To DATE: 8-28-18 0 2 Casing Stickup PERMIT NUMBER: OSP181248 DATE OF ISSUE: 8-13-18 TAX IDENTIFICATION NUMBER 06706225000 2 4 Overburden Is well located at approved permit location: NYes No 4 81 Silty Sand Method of Drilling: ®air rotary cable tool 81 109 Silty Sand & Gravel Depth of Well: 159' 109 128 Clay& Silt Casing Type: Steel Wall thickness ,250 inches 128 145 Clay&Gravel Diameter: 6 inches, depth 159 feet Liner type 145 153 Silty Water& Gravel Static Water Level: 35 feet 153 159 Sand & Gravel Water Recovery Rate 30 gpm ❑ gph Method of Testing Air Well intake Opening Type: XI open end open hole ❑ Screened Start feet Stopped n Perforations Start feet Stopped Grout Type: Bentonite Volume: 50 lbs _ Depth:from 2 feet,to 42 feet Well Disinfected Upon Completion: Myes I I no Method of Disinfection: Chlorine 50 PPM Comments: WATER QUALITY TESTING Collibrm 14u. Co1/100mL Nitrates O. 3 mgIt. Arsenic 1,1b Drillers Name: Cole Sullivan ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough: Department of Environmental Conservation. 1bLLi(,AEN DOC CO dba WATER WELLS P.O. Box 670269,Chugiak,AK 99567 688-2759 www.sullivanwaterwells.com Pump Installation Log Well Drilling Permit Number:SW OSP181248 Date of Issue 8-13-18 Parcel Identification Number: 06706225000 Legal Description Property Owner Name&Address Denaly Estates Block 2 Lot 18 Midnight Sun Construction Pump Installation Date: 3-14-19 Pump Intake Depth Below Top of Well Casing: 130 feet Pump manufacturer's Name: ' F&W Pump Model: 4F07P05301S Pump Size: 1/2 hp Pitless Adapter Burial Depth: 10 feet Pitless Adapter Installer: Whitters Construction Disinfected Upon Completion? ® yes ❑ no Method of Disinfection: Chlorine 50 PPM Comments: Pitless Manufacturer: MartinsonOSP Pump Installers Name: Sullivan Water Wells Attention:The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. w�4 c h <9L � 3 r 'o ' 0 sCO d0 ! f.-�l� v\• �r (`-f)) L` o - P1 o� {j��i^ O s 30.0 C> n y 0 ori�6 w fes) m ''` 00 —1- " 3 > �' z .7 ! ,1L ., r, �� Or ♦ems c(J, r 1... (�')v i� 111 x, p!S• 0 {�r�j \ :7 0 O -. m7 U z ;' rI 20 fi j `.` C"1 / P1 > o f N N3 •I • L ' 'r \o - - � \ ! I / fo Q �i � (f)imw r' r \ • r r r `, .O m - I Cl) • C -a -I ° 7 ..off . m ! 7a m Q r., w a�yo "r ! • j \ . `r • nfl - 53.6' • • I�-n coDDo pTI -1- CJ \ :l7 • 0 / Q \ rm o \ a 1 • / \ f F 73 °r,. �' %�' ' art 1 -0vl v1 C) \ '/� t I , 12.5• ••) Irl U r ff �— 0) - 1H .J-1 • -r N O \ I `1 8 -. JI j as 'a \ ,00 w mr- p.-..- Z • I.... r , co• • v/ ••r • - O • • l'o(j: I • .,cn I S 00'40'15”Vi 328.94' '\ vv s in in ',��� J�oIf C - C cr t ` 2: as } t 0 PLOT PLAN AS BUILT _X SCALE __1" = 50' GRID SW 0362 j _ 1 Pro act No. 18-288 BS •,R,,,,k ►r „iiiiiiiime"',..,. Associates , 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 / ' Lang & ince (907) 522-6476 Phone ,. ��4 , Y (907) 522-4625 Fax � F �d�4� `-' c›--- Professional Land Surveyors kenOlangsurvoy.com o jonothanOlangsurvey.com �O./\� .... -.496.. „. , s O I hereby certify that I have surveyed the following described .. , �0 Y g ( property: (/) , 49_ 4 v LOT 18, BLOCK 2, DENALY ESTATES SUBDIVISION (PLAT No. 2018-29) �:. H � 0 Anchorage Recording District, Alaska, and that the improvements situated thereon are , � ' Q within the property lines and do not encroach onto the property adjacent thereto, that t if . " no improvements on the property lying adjacent thereto encroach on the surveyed "'"' � . •�'.•CA premises and that there are no roadways, transmission lines or other visible vAp KENN�iH N o`� easements on said property except as indicated hereon. U/,�% l ct`t• -' �� Vo-� '.. - r foo Dated this the _ Day of . , . at Anchorage, Alaska �qt,F0 A' LS-520 ,•••o Q k\QRO SSIONAL 1,ac7v It is the responsibility of the owner to determine the existence of any easements, Qpppppoa covenants, or restrictions which do not appear on the recorded subdivision plot. AECC963 412.1 f 18 Ko M a°","PAlirk0, MUNICIPALITY OF ANCHORAGE On-Site Water&Wastewater Program �� S.� PO Box 196650 4700 Elmore Road V ' Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax (907)343-7997 httpa y/www.muni.org/onsite 'i ;,_ 1-:. _� Dcpait inc iit On-Site Water & Wastewater System Permit Permit Number: OSP181248 Effective Date: 8/13/2018 Work Type: WellSeptic Initial Expiration Date: 8/13/2019 Tax Code Number: 06706225000 Site Legal Address: DENALY ESTATES BLK 2 LT 18 G:0362 Site Mailing Address: 25422 BLACK PINE CIR, Eagle River Owner: GENTEMANN LISA M & JAMES L Lot Size in Sq Ft: 83018 Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: 3 This permit is for the construction of: 2 Disposal Field 0 Septic Tank 0 Holding Tank 0 Privy Ii Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: The recorded plat for this subdivision notes that artesian wells are common and that special drilling methods may be required to prevent waste of water via surface discharge. ll Received By: ' �It. ♦ / Qi5 lu y , .�� Date: Issued By: Abtr,e4 / • // Date: gAW i EPU414 MUNICIPALITY OF ANCHORAGE • Community Development Departments Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On-Site Water& Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 067-062-25 Property owner(s) LISA & JAMES GENTEMANN Day phone Mailing address PO BOX 770603, EAGLE RIVER, AK 99577 Site address NHN BLACK PINE CIRCLE Legal description (Sub'd., Block & Lot) DENALY ES-FA-TES B2 L18 Legal description (Township, Range & Section) Lot Size 83,018 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field ❑X Initial El Single Family (SF) ❑X (w/wo ADU) Septic Tank ❑X Upgrade ❑ Duplex (D) (_ Holding Tank ❑ Renewal [ Multiple Dwellings [ Privy ❑ (SF and/or D) Private Well ❑X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. 72X2 Ignature of property owner or authorized agent) Permit/Rush Fees: -9p`f!' Waiver Fees: Date of Payment: $1(o L tZ Date of Payment: Receipt Number: -`3CI Receipt Number: Permit No. OS PI gigY 7r Waiver No. Permit App__ ::...c Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181248, Rebecca Carroll, 08/13/18 NOTES & SPECIAL PROVISIONS: 1, SCOPE AND SPECIFICATIONS: % Ch -Sit rat"" s TION "R �D C 1.1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS - _A (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH � CP18i24$ AMC 15.65 AND 15.55. 1.2. SCOPE OF WORK: INSTALL NEW 20008 SEPTIC TANK, AND SOIL ABSORPTION SYSTEM. INSTALL WELL � --- --- 1.3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 12 FEET -BELOW GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER SEPTIC � ' ��- TABLE _- IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 12 FEET BELOW rEXISTlNG GRADE NOTIFY THE ENGINEER IMMEDIATELY. -1.4. STRUCTURES DEPICTED ON THE SITE PLAN ARE BASED UPON ONE. OF THE FOLLOWING: CONCEPTUAL PLOT PLAN DEVELOPED BY OWNER; A PLOT PLAN ` DEVELOPED BY RLS; OR A SURVEY AS -BUILT. 2. CONSTRUCTION SPECIFICATIONS: - -- WELL E - y 2.t. ALL EXCAVATION DEPTHS ARE ADVISORY. THEY ARE TO BE VERIFIED AND MAY BE MODIFIED BY THE ENGINEER IF ACTUAL FIELD CONDITIONS VARY FROM E311�Ck Pine Circe TRUE NORTH SCALE i"= 60• ^- THOSE USED TO PREPARE THE DESIGN - 2.2. EXCAVATE THE DRAIN FIELD. BOTTOM OF EXCAVATION SHALL BE LEVEL AND SCARIFIED. RECORD ELEVATIONS AT BEGINNING, MIDDLE AND END OF TRENCH ti \ BOTTOM. CONSTRUCTION EQUIPMENT SHALL NOTOPERATE ON THE FLOOR OF THE EXCAVATION. ANY MATERIAL COMPACTED 8Y THE OPERATION OF THE - "'�"s '� � -�-�- --� ---- ----- ----- -- - CONSTRUCTION EQUIPMENT SHALL BE REMOVED AND REPLACED WITH UNCOMPACTED MATERIAL _ \ - 2.3. PLACE THE SEWER ROCK TO THE SPECIFIED DEPTHS. DO NOT CONTAMINATE SEWER ROCK WITH NATIVE MATERIAL OR SPOILS FROM EXCAVATION. LEVEL `' \\ ` a ROCK SURFACE TO -E 1" PRIOR f0 INSTALLING THE PERFORATED PIPE. 2-4. ALL PIPE SHALL BE PVC CONFORMING TO ASTM D3034 OR ENGINEER APPROVED EQUAL. MINIMUM SOIL COVER SHALL BE 3 FEET OVER THE PIPE AND 4\ \ t 18 n FEET OVER THE SEPTIC TANK. ONE INCH OF INSULATION MAY BE SUBSTITUTED FOR t FOOT OF SOIL COVER. \ \ \ ` \ \ \ \ a 2.5. ALL INSULATION SHALL BE 2" THICK DOW HI -40 INSULBOARD OR ENGINEER APPROVED EQUAL. CENTER INSULBOARD WIDTH OVER SEPTIC TANK OR LINES. \ \ \ IG K nQ 2.6. GEOTEXTILE SHALL BE MlRAF! 140S OR ENGINEER APPROVED EQUAL LAP ALL JOINTS 2 FEET MINIMUM. 2.7. COVER THE DISTRIBUTION PIPE WITH A MINIMUM OF 2" OF SEWER ROCK AND COVER WITH GEOTEXTILE BEFORE PLACING INSULATION AND BACKFILL, 2.8, MATERIAL USED AS FILL SHALL BE CLEAN AND FREE OF ORGANICS, TRASH AND CONSTRUCTION DEBRIS. \ \ \ \ \ x a 2.9. SLOPE ALL FILL MATERIAL TO DRAIN AT 2% MINIMUM SLOPE AND 3:1 MAXIMUM SLOPE AND IN SUCH A MANNER THAT PONDING AT OR NEAR THE DRAIN FIELD DOES N07 OCCUR, THE FILL SHALL BE LEFT AT 6" HIGHER THAN SHOWN TO ALLOW FOR SETTLEMENT. SEED SURFACE AFTER COMPLETING INSTALLATION AS\ \ \ \ \ \ \ j �AAaw PER MOA CODE. EVELOPED LOT \ ~ 3BR \ \ \ \ ig 2.10. RECORD THEE FINISH GROUND ELEVATION OVER 'THE BEGINNING, MIDDLE AND END OF SYSTEM. 2.1 1, MAINTAIN 5' SEPARATION BETWEEN PERCOLATION HOLE AND THE DRAIN FIELD TRENCH. \ \ SFD(P) \ \ 1 \ \ \ 2.12. EXPOSE, PUMP AND FILL LOG DISPOSAL CRIB OR CONCRETE TANK WITH SOIL TO ABANDON AW WITH MOA CODE IF NEEDED. \ INSTALL WELL {P}/" 3. CONTRACTOR RESPONSIBILITIES: \ \ 100.3\ \ \ \ \ UNDEVELO TH- 11 3.1. THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) SHALL HAVE ANY WELL LOCATION AND SEPTIC LOCATION STAKED AND ANY LOT LINE \ \ \ \ \ INSTALL t0DOG SEPTIC TANK AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE\ __ - _ _ 124.9 BEFORE AND DCO AFTER WORK. 3.2. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED. � \ \ � � \ � \ � \ ` _ - \ \ \ \ � Z 3.3. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES.\ \ aa5 3.4. THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING AND LOCATES SHALL BE IN PLACE \ \ \\ \ \ ~ \ \ \ - - - PRIOR TO NOTIFYING THE ENGINEER. �- \ \ \ \ \ \ \ -J 3.5, THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SITE CONDITIONS/LIMITATIONS \ \ \ \ INSTALL ABSORPTION FIELD P __- POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN. 6 Fx5 'Wx4 0' D 6 0'T 3.6, AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED -LINE AS -BUILT DRAWINGS TO THE ENGINEER. THE RED -LINES SHALL INCLUDE -- _ _ \ \ , s \ \ ENDS ELD ' \ \ W/ MTs COs EA i' DOF FI 6 \ PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS, AND TANK ELEVATIONS. •., � � � ,, -` -`-- \ � ADD 2" R.I.AND ENSURE 3, O' \ f l � - 3.7. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF EXCAVATION, TOP OF PIPE WITH CLEAN --OUTS - a - COVER \ f AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING. _ RESERVE AREA (Nim \ `> \ \ Cl. 4. THE CONTRACTOR SHALL SIGN THE FOLLOWING: i CERTIFY THAT ALL WORK WAS PERFORMED IN ACCORDANCE WITH THE APPEND PERMIT, AND ANY AND ALL \ ~ 6OLFx 5, O'Wx 4.0 E. D., 6.O'T.D. \ \ \ \ 475 CHANGE ORDERS, AND THAT THE AS -BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS CONSTRUCTED, \ Hwa `w 1 \ \ \ LLJ �° , UNDEVELOPED_LOT lu CONTRACTOR: �- -- BY: ^- TITLE:-----_-�_--DATE:\ \ \ . -- - ` ,�--- _ UNDEVELO_PEfl LOT -"44.4 _ \ \ \ \ \ X70 m-�1g v3 465 PRIMARY/RESERVE DESIGN SOILS LOG PARAMETERS TH-PES / \ \ \ \ •, \ _ 1 � Ch U PRIMARY DESIGN PARAMETERS Eft , SM NO. BEDROOM: 3(450 gpd) 2 -- TANK -TANK SIZE: 1000g s PERC RATE: 6.9 MPI SOIL RATING: 0.8 GPD/SF 4 AREA ROD: 562.5 SF REDUCTION FACTOR: 0.5 5 ADJUSTED ABSORPTION AREA: 281 .2.5 SF - READING DATE NET TIME WATER LEVEL READING NET DROP RATE (MPI) 1 25.RJLi8 CLEANING OUT 5.900"-- 7 2 10 MtN 7.582" 1.682" -}5.9 3 -. 5.900" 4 --=SSS f 10 MIN 7,335" 11435" 6.9 60.DLFx5.D'Wx4.0' E.O., 6.0' TO 3 6 \ 10 MIN 7.33p'° 7.430" 6,9 V A \0 Lu \ UNgVEL0k\D LOT 450 \ r \ \ i ,v v v ti \z UA J ABBREVIATIONS ` \ TH TEST HOLE (P) PROPOSED SYS. TYPE: WIDE TRENCH 4,0'ED MIN LENGTH: 57 LF 6 SM SAND & GRAVEL / W \� .. WATER ll ,E WELL RADIUS / \ SCO CLEANING OUT '• Sm 7 WAS GROUND WATER BOLL TEST RESULTS/ANALYSIS Lot 13 N0. USE. 8 ENCOUNTERED? N e PERCOLATION RATE S.p: HSinch) (Hydrologic Sails Group: HSG A) --=SSS f \� 4W,SEPTIC \ MT TYP MONITOR TUBE NO. TYPICAL 60.DLFx5.D'Wx4.0' E.O., 6.0' TO 3 \ 44 , 5°•'° TOTAL AREA: 300.0 SF s IF YES. AT WHAT PERC HOLE DIAMETER 6" DEPTH? -NA- TEST RUN BETWEEN 5 1 T AND 6 FT, 70 TEST RUN FOR OVER AN HOUR, REVISIONS RESERVE. DESIGNNIC DEPTH TO WATER AFTER LAST THREE READINGS PROVIDED. REV 1:°8709+2018 ., 11 MONITORING? - 12.0' - - BEDROOM: 3(450 gpd) DATE:NO. TANK SIZE: 10009 12 PERC RATE: 6.9 MPI 13 COMMENTS: Test hole excavated by WHITTERS SOIL RATING: 0.8 GPD/SF AREA ROD: 562.5 SF 14 REDUCTION FACTOR: 0.5 PERFORMED BY: Joseph Lawendowski, i CERTIFY THAT THIS TEST N o ADJUSTED ABSORPTION AREA: 281.25 SF t5 GM WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL o q SYS. TYPE: WIDE TRENCH 4.0'ED t6 GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. - -- - 'MIN LENGTH: 57 LF ` � ' ,7 oa 2 . USE: �.% <� UN 60.OLFx5.0'Wx4.0' E.D., ��TD 18 =N TOTAL AREA: 300.0 SF sHEET� 19 ._ BOH DATE PERFORMED: 25JUL18 tQFM1 3.5' i i I I Lot 6 5 2) SEE ENGINEER'S PLANS FOR WELL & SEPTIC LOCATIONS Unsubdivided / / Lot 16 z m o: U � O O b r a. c E Q c O U ®o�E@ N b 0 to >i.N y.0 0 �aNC04�c j W c O d4P�1`.d p 4 4 o U V) it ®- 0 o. > W V) eU -0 U C J r0r� J YJ CD V) _ to O X) •�i z V) IL 0 o L- CL :0 . oyvQ z .. W 4�¢ --- z} a) 00 z'Q`o° 'REG\�o IP - I PA Co in N _ 0,`m o z m o: U � O O b r a. c E Q c O U ®o�E@ N b 0 to >i.N y.0 0 �aNC04�c j W c O d4P�1`.d p 4 4 o U V) it ®- 0 o. > W V) eU -0 U C J r0r� J YJ CD V) _ to O X) •�i z V) IL 0 o L- CL :0 . oyvQ z .. W 4�¢ --- z} a) 00 z'Q`o° 'REG\�o O a- v! 0,`m o mo m m� a p E 0- 0 0 0) N+"GL v c 'o 0.0 otOq O p GL ^ r b p L cco0 O o ® O Do C ►. ®Z C c Cbm. (A a O any L V�pCi0Cc L m a r0 00 0 E..1%'m me Omrm m r "' r» t r c� i. c a Onoa�i o o>oc00a0 c L �o 06 CL c o o tn m030 « 0 ym,QcAoO.- 00 'o ZIn,0o 0mi o act 3 Q O m C ® O 0L >0oa A r »- IT =Ina 0 p O c �i oc ct G. �v `o �- C.) L. as o `a n :EmIxeaEco '0Lb V00m m>� h L tl) 0=20'C .oE-°,a%m .c » cc moot 0— => .c _ d3cn.m a v Epubta n314 MUNICIPALITY OF ANCHORAGE Development Services Department \, . if Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On-Site Systems Approval Parcel I.D. 067-062-25 Expiration Date: ! ` 7--rq 1. GENERAL INFORMATION Complete legal description Denaly Estates B2 L18 Location (site address) 25422 Black Pine Circle Current property owner(s) James & Lisa Gentemann Day phone Mailing address 25422 Black Pine Circle Real estate agent Day phone 2. TYPE OF DWELLING: El Single Family(w/wo ADU) Ir � - ❑ ,Duplex is *, ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well Private Septic El Water Storage El Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ l 70 Waiver Fee $ Date of Payment 61 ) Date of Payment Receipt Number L $51(16 Receipt Number COSA# O3CJ91 ZZ Waiver# )09. 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. In conducting an adequacy test, I attempt to provide a thorough,conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition,ground water levels that may fluctuate during the year,and the water usage of the family being served by the system.These conditions are outside the control of the evaluator of this system.All systems eventually fail and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments.Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system.The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services Phone (907) 745-8200 Address P.O. Box 1807 Palmer, AK 99645 Engineer's Printed Name Steven R. Pannone P.E. Date 06/04/2019 */491 i. .* 6. DSD SIGNATURE ....�.t` System #1 Approved for .D bedrooms "$even • •antiotAe System #2 Approved for bedrooms •;•••. 8149 Disapproved ••'' Conditional approval for bedrooms, with the following stipulations: ```ottc ((((roI'f WA ON PRS �� Im^ �wRAM X111) S¢'RViCSSV1NN ,�41)))))))))1‘l\ By: ` Original Certificate Date: ( '-7-- f I 7 The Municipality of Anchorage Development Services Division(DSD)issues Certificates of On-Site Systems Approval(COSA)based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist Wee sheet COSA Checklist Legal Description: Denaly Estates 82 L18 Parcel ID: 067-062-25 If more than 1 septic system on lot: COSA Checklist# of Structure served by this system 1 A. WELL DATA ❑■ Well log is filed with Onsite (or attached) Well production at time of test 30** gpm Date drilled 8/2818 Water storage tank volume n/a gallons Total depth 159 ft Well disinfected for coliform test? ❑Yes ❑✓ No Cased to 159 ft ❑■ Coliform bacteria is Negative El Sanitary seal is functioning correctly Nitrate 0.513 mg/L ❑ Nitrate less than MRL (ND) ii Wires are properly protected Arsenic ug/L 0 Arsenic less than MRL(ND) Casing height(above ground) 24 in. Collected by Pannone Engineering Date of flow test for COSA n/a Date of Sample 5/2 019 Static water level at beginning of test 35** ft. Comments ** From Well Log B. TANK DATA C. LIFT STATION Age of tank(s) <1 years ❑ Required maintenance completed Tank type/material " Age of lift station years Measured operating fluid level in septic tank n/a Lift station material Q Standpipes/foundation cleanout per record drawing Comments: Date of pumping n/a D. ABSORPTION FIELD DATA Shallow Trench • Which system tested (date installed) 8/29/18 Adequacy test date n/a Q ALL standpipes present per record drawing Results Pass For 3 bedrooms Total measured depth from grade 6.5 ft(max) Fluid depth prior to test in Measured depth to pipe invert from grade 2.5 ft(min) Water added gal ❑ N/A—pressurized field New depth in ID Monitor tubes go to bottom of effective. If not, state Elapsed time min depth into effective Code-required soil cover over field Final fluid depth in ❑ System presoaked Absorption rate gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment(past 12 months) date of test) If yes, enter date Gallons introduced gallons Comments/Deficiencies: COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' Community Sewer Manhole/Cleanout > 100' ❑✓ Yes if No ft 7 Yes if No ft Neighboring Tank> 100' 0 Yes if No_ft Private Sewer/Septic Line > 25' E Yes if No ft Absorption Field on Lot> 100' 0 Yes if No ft Holding Tank > 100' 0 Yes if No ft Neighboring Absorption Fields > 100' Animal Containment> 50' 0 Yes if No ft 0 Yes if No ft Manure/Animal Excreta Storage> 100' Community Sewer Main > 75' 0 Yes if No ft ✓0 Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0 Yes if No ft Surface Water> 100' 0 Yes if No ft Property Line > 5' 0 Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' 0 Yes if No ft Private Wells > 100' 0 Yes if No ft Water Main > 10' 0 Yes if No ft Community Wells>200' 0 Yes if No ft Water Service Line > 10' 0 Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' 0✓ Yes if No ft If absorption field is under driveway comment below Property Line > 10' 0 Yes if No ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells> 100' 0✓ Yes if No ft Water Service Line > 10' 0 Yes if No ft Community Wells >200' 0 Yes if No ft Surface Water> 100' 0 Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION �P,��OF Ac.q�� B 1 certify that t have determined through field inspections and review me co - •%:9 fh of Municipal records that the above systems are in conformance with e•'•.' �`• �` MOA COSA guidelines in effect on this date. ✓ ` • . .. 00$ . '' .. ,yam COSA Checklist yellow sheet