HomeMy WebLinkAboutPROSPECT HEIGHTS #2 BLK 7 LT 5 Onsite File Prospect Heights # 2 Block 7 Lot 5 #015 - 134 - 83 Municipality of Anchorage On-Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181280 PID Number: 015-134-83 Dwelling: F91 Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project:❑ New ❑ Upgrade Name: Blase & Brenda Burkhard ABSORPTION FIELD ❑ Deep Trench❑ Shallow Trench ❑ Bed ❑ Mound Address 10100 Lone Tree Dr. Anchorage, AK 99507 ❑ Other Phone Number of Bedrooms Soil Rating depth from original grade 240-1638 3 JTotal 1.2 GPD/SF 9.7 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 6.7 Ft. Gravel depth beneath pipe 3.0 Ft. Subdivision Block Lot Prospect Heights #2 7 5 Fill added above original grade 0.0 Ft. Gravel length 45.0 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 388 Ft 1 Ft. Well >100' >100' N/A N/A >25' TANK [� Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 11,000 Gal. Surface Water >100' >100' N/A N/A Material Number of compartments Lot Line >10' >10' N/A N/A Steel 2 NA Foundation >10' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Pitless adapter for well was made by Pump on level at in. Pump off level at in. High water alarm at in. Campbell Manufacturing, and installed at 10' below grade by AK Underground. Pump make and model Electrical Inspections performed by House to tank D3034 Tank to PIPE MATERIAL drainfield D3034 Installer AK Underground Drainfield D3034 CO/MT Inspector J. Millette BENCH MARK (Assumed elevation) 100 ft Inspdecctes 15' 11/13/18 11/13/18 Location and description 2nd aro 4th Threshold of SW wall door. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp OF "'•••q �� Conditional Approval: Date ���P,.••°`""""" -9th ' .......... ... 10. ®.ovus.um..n.nus......vn........... nu10 g MICHAEL E. ANDERSON s P, n A Approved ALct-ruDate °. NO. CE-4387 �������,•.,•.11/26/19 �.•' ��� yo..,......® Inspection Report-9-1-12.doc PROSPECT HEIGHTS #2 B7 L5 LOT 5 ADJACENT SYSTEM (APPROXIMATE LOCATION) PID #'015-134-83 1000 GALLON FCO SEPTIC TANK B 2CO •'VZ V1 EXISTING WELL CO 45' LONG x 5' WIDE x 3' MT1 EFFECTIVE TH#1 ` ABSORPTION TRENCH \\ CO 100' WELL RADIUS ALTERNATE SITE / 10' UTILITY EASEMENT UPPER OWALLEY ROAD ENGINEERING A;pkE OF...qL � 00 P"" "` ...q � ®4 ` 49th ........................................ n MICHAEL E. ANDERSON •; NO. CE -4381 •••'•n1 /18/1x9 •"••"' C<� 0 50 100 km m FEET A B FCO 10.0 29.2 SV1 38.5 44.4 SV2 43.2 50.1 2CO 45.1 52.3 MT1 52.5 53.7 C01 50.8 52.8 MT2 72.8 49.5 CO2 74.6 51.5 LEGEND CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT -MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE PROSPECT HEIGHTS #2 B7 L5 ENGINEE 0.ING PID # 015-134-83 NO GROUND WATER 4/5/18 77.7 PROFILE AS -BUILT (NO SCALE) :• k th �g '#, ... ...., ..I ....................... .................. ..� MICHAEL E. ANDERSON NO. CE -4381 T'•.,>�a 9/18/19 s,e.''�CV� FLS51�®����� 00:20 907--:45-ii O2 ALPTt4E DRILLING Pg -,GE 01?131 J'Allpine Drilling & Enterprises Wel! Log w83 f'etn�itl�`ui�nbex: #�si7t'18'128r late. of f4 ne: 9i7-3-78 Parcel Identification ?{dtr.mber: 01513�OO-1 Date Started, 12-3.1-1 # irate Colnpiet�ed- 1-2-19 is well 3.Qcatsd at a} proved peru.dt location' x Yes No Legal Descriptioin Prospect Heights #2 Block 7 LcI 5 Property (Mh aer'`dame & Address; OaS6 BUIP 1alt Borehole Data: Depth(ft) Soil Type, Thickness &'gates Stmt" Fiom To Stick-up 0 ' Organics & silt ? 4 silt 1 gravelly silt 66 bedrock 56 346 WATER QUALITY TESTING Coliform 1tiie9 Coi/100mL Nitrates mg/L Arsenic r1D ug/L iklzoli`t Method of Dii%ling, x air rcotar; ❑ CaMe tool Casing tyke: steei Wall Thickness- jig i11C} 03 Diameter: 6 inches Depth: #59 feet Liner Type: —...— Dianleter: inches Depth; _ feet Casing 3tiClLUP abkll a grautkd t@et Static ew`ater level (firm ground level): 7`0 feat Pumping level: 3410 fent after 4 hours D'aw ?ing 1 gptn Recovery Rate; 4 �Tpli method of Test.iaig: L7ir ll e Well betake opening 'r'pe: Open End x Open H01e L] Soreened Star feet Stopped feet [] Perforatiotys Start—feet Stopped ___ feet Ga'oll 'I`ype: bentonite Volume; 2�.s vet 7 forst Pump: Intake Depth feet Pump size _—_—_hp brand NaMee `N,ll Disilifef tccl'upon c-owpletion? x Yes ❑ 1'tio Method of Dishifection: chlorine tablets CUumlents: Well Driller: Alpine Drillir;g & E111OPrises Po Box 110496 Anchorage AK 99511 03/31/2013 212:74 907-345-D202 ALPINE DRILLING PAGE 02/02 A MUNICIPALITY OF ANCHORAGE M WE M --w, N &u L w a a M a a Az a WA w w M 4 M z S a =a mm R a a w Development Ser%eioas Department i a I Phone: 907-343-7904 On -Site Wator & WaF ,tewater Sectilall Fax' 907-343-7997 Purnp instal ation Log Well Drilling Permit Number: '18,1280 Dateof Issue. '10,3 18 P21'cel Identification Number: D ;seal Description Owner Name Address: 7 1. PROSPECT HEIGHTS #2 1 10720 Schuss or, lAncho,-aae, AK 99516 Pump Instalivition Dat.2- -1 -18 -201� Pump Intake Dep"ItEelow Top 4)f w;jE Casing: 342 Pump Manufacturer's Name. Grundfos Pu-inl0viodel: 10 SQE15-330 rump SIZQ.- - .5 4P feet Pitless Adapter Bvrial Depth: NIA feet U0 l� . Pitkss Adapter Maaufactm-er's Name: N/A �,c,,, V Pitless Adapter NIA &C-, 4cin Well DisiHfcctedUPOn Conlipletion'.) L1 Yes E3 No Method ofDll,fnfecfiow chictinetaoieci comments: PLEASE SAVE FOR 003A, Pump Installer Name: A 'a N row Pump & VVe,11 Srai-ViCe, LLC company.: ryfailing Address: P.0. Box I '104 9 a Anchorage AK City: State; Z;P: Attention. The pwip instiller shall prcyvjdt,,,t p7yrnp instailation)o3 t0 Oa -site within '%0 day Ot"P111111), in D MUNICIPALITY OF ANCHORAGE On-Site Water&Wastewater Program �� PO Box 196650 4700 Elmore Road � r Age 1 Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 http://www.muni.org/onsite §: 44'CHC R On-Site Water & Wastewater System Permit Permit Number: OSP181280 Effective Date: 8/23/2018 Work Type: WellSeptic Initial Expiration Date: 8/23/2019 Tax Code Number: 01513483000 Site Legal Address: PROSPECT HEIGHTS #2 BLK 7 LT 5 G:2540 Site Mailing Address: Owner: BURKHART BLASE & BRENDA Lot Size in Sq Ft: 128242 Design Engineer: FORGE ENGINEERING Total Bedrooms: 3 This permit is for the construction of: D Disposal Field L Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing iv By: Z-4/6(1W-/i/ Dat :Rece ed e A Issued By: falitetik azAit,oref' Date: 817.? PLANS MUNICIPALITY OF ANCHORAGE •F Community Development Department �� - Phone: 907-343-7904 Development Services Division -- Fax: 907-343-7997 On-Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 015-134-83 Property owner(s) Blase & Brenda Burkhard Day phone 240-1638 Mailing address 10100 Lone Tree Drive, Anchorage, AK 99507 Site address NHN Schuss Dr Legal description (Sub'd., Block & Lot) Prospect Heights #2, B7 L5 Legal description (Township, Range & Section) Lot Size 128,242 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: 10 all that apply) Absorption Field X Initial (Xl Single Family (SF) X (w/wo ADU) Septic Tank 1-1 Upgrade Duplex (D) ❑ Holding Tank ❑ Renewal C Multiple Dwellings n Privy ❑ (SF and/or D) Private Well Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 4 311' Waiver Fees: Date of Payment: c9Ohi Date of Payment: Receipt Number: �Q I(1110- l Receipt Number: �} Permit No. ( )SPI SJ 9 6 Waiver No. Permit App_..-. ::....c August 20, 2018 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Prospect Heights #2, Block 7 Lot 5 – NHN Schuss Dr 8/20/18 Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 3 -bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. The ground surface on the lot slopes toward the west at about a 10-25% slope, although there are areas on the property that exceed 25% and approach 50% for short sections. It is in the flatter area near the center of the lot that the new septic system is located. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Drainage arrows are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. The soils log and perk test was done by another engineer, and we are unable to make any changes to it. Although he visually classified the layer as “SPg – Sand w/ Gravel & Cobbles”, we took a sample to the lab for a formal classification, since the perk rate was under 1 min/in. The lab analysis indicated it was >56% sand and labeled it officially as “Poorly-graded sand w/ silt and gravel – SP-SM”. This gradation is acceptable per code to use as an in-situ sand filter with a 1.2 GPD/SF application rate. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 10’ away. Please refer to the attached test hole logs, soils lab analysis, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181280, Rebecca Carroll, 08/23/18 12.3%8.6%3.7%920.0930.0916.0918.0922.0924.0926.0928.0932.0934.0FCO 10050 0 FEET 1"=50'3-BDRM HOME PROPOSED WELL 1000 GALLON SEPTIC TANK NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND TH#1 SCH U S S DRI V E PROSPECT HEIGHTS #2 B7 L5 - NHN SCHUSS DR Aug 23, 2018 SLOPES > 25% SLOPES > 46% UPPER O'MALLEY ROAD 10' UTILITY EASE M E N T MT MT CO CO 2CO INSTALL 45' LONG x 5' WIDE x 3' EFFECTIVE ABSORPTION TRENCH ALTERNATE SITE 10' UTILITY EASEMENT ADJACENT SYSTEM (APPROXIMATE LOCATION) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181280, Rebecca Carroll, 08/23/18 PROSPECT HEIGHTS #2 B7 L5 DESIGN FACTORS: SYSTEM REQUIREMENTS: 450 GPD PEAK FLOW PERK RATE: 0.13 MIN/IN APPLICATION RATE: 1.2 GPD/SF 5' WIDE DEEP TRENCH SYSTEM 1000-GAL SEPTIC TANK TYPICAL TRENCH SECTION (NO SCALE) 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 5' 6" 6" 6'-6" 3' Aug 20, 2018 NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY BOTTOM OF TRENCH: 10' BELOW GRADE FLOW LINE ELEVATION: 7' BELOW GRADE TOP OF TRENCH: 6'' ABOVE GRADE 450 GPD / 1.2 GPD/SF / 3' DEEP * 0.58 REDUCTION = 43.8 LF TRENCH REQUIRED (45 LF SPECIFIED) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181280, Rebecca Carroll, 08/23/18 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181280, Rebecca Carroll, 08/23/18 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181280, Rebecca Carroll, 08/23/18 916 917 918 919 920 921 922 923 924 925 926 927 9 28 9 2 9 930 931 932 933 936 937 938 939 940 941 942 943 944 9 3 3 934 935 936 937 938 939 940 935 936 937 938 939 940 941 942 943 944 945 946 947 948 945 9 4 6 947 932 918 919 9 2 0 906 907 908 909 9 10 911 912 913 914 915 916 917 918 931 931 934 932 933 9 3 1 931 932 9 2 5 926 927 928 9 3 0 929 928 927 926 9 3 0 931 920 921 922 923 924 925 926 927 928 921 9 2 2 9 2 3 9 0 1 9 0 2 903 904 905 906 907 908 909 910 911 912 913 914 915 916 917 918 919 9 3 1 928 929 930 931 927 928 929 928 9 2 9 9 3 0 930 931 932 933 934 927 927 929 932 933 93 4 93 5 930 93 1 929 927 928 929 930 931 932 924 925 926 927 928 929 930 931 928 929 926 927 926 927 930 930 934 934 9 3 3 932 933 930 928 929 927 931 932 933 934 933 934 929 928 931 932 932 9 3 3 932 933 931 931 932 932 933 933 933 9 2 8 9 2 7 927 928 931 932 FF=933.0 2,514 SF 2,026 SF FF=932.0 2.94 acres BLOCK 7 / LOT 5 PROSPECT HTS. SUBD. ADDN. NO. 2 FOUND MONUMENT 3-1/4" BRASS CAP ON 1" IRON POST, FLUSH W/ GRADE. ELEV = 901.5' 10' UTILITY EASEMENT SCHUSS DRIVEUPPER O'MALLEY ROAD FOUND 5/8" REBAR FLUSH W/ GRADE. ELEV = 928.0' FOUND 5/8" REBAR FLUSH W/ GRADE FOUND 5/8" REBAR FLUSH W/ GRADE. ELEV = 933.0' MOA GRID SW2540 MOA ZONING DISTRICT R-9 25' SECONDARY FRONT YARD SETBACK 2 5 ' P R IM A R Y F R O N T Y A R D S E T B A C K 15' SIDE YARD SETBACK2 5 ' R E A R Y A R D S E T B A C K 321.58' (NR) N 89° 59' 05" E238.25'S 00° 03' 12" E10' UTILITY EASEMENT 3 3 2 .5 1 'N 6 0 ° 2 4 ' 2 8 " E 2 9 3 . 8 2 'N 3 7 ° 5 9 ' 3 2 " W1 25 .0 0 'N 52° 00' 28" E Δ = 48° 13' 07" R = 130.00 T = 58.18 931.5 931.0 930.5 933 934 931 930.75 930.0 931.75 TYP @ FOUND 931.75 TYP @ FOUNDATION 1 5 ' SI DE YARD SETBACKGB FOUND MONUMENT 3-1/4" ALUMINUM MONUMENT 0.7' AGL. ELEV = 901.0' 931.25 6 0 . 0 ' CONST. COORD. CONTROL POINT N 26.552' E -163.398' N 80.705' E -13.701' N 91.664' E -153.944' N 145.722' E -31.265' N 175.155' E -54.217' N 65.355' E -133.188'60 .0'1 3 4 . 0 '56.056.03 7 . 3 3 40.02 6 .010.6756.09.335 . 3 3 5 . 3 39.334 . 0 4 . 0 1 3 .3 3 5 . 3 3 5 . 3 3 3 3 . 3 3 4 . 0 10.672.03 .33932 INV=931.25 INV=930.75 931.5 SURVEY CONTROL POINT 61°07'23.37502"N 149°44'05.36911"W ELEV = 939.2' PAVED ROAD -100' ROW PAVED ROAD -60' ROWLAKEWOOD HILLS #4 BLOCK 1 / LOT 1 PROSPECT HEIGHTS #2 BLOCK 7 / LOT 4 PROSPECT HEIGHTS #2 BLOCK 7 / LOT 6 PROPERTY CORNER OF RECORD NOT RECOVERED THIS SURVEY ELEV = 923.5' 5 6 4 4 2130.0'N 104.976' E -82.394' N 58.240' E -45.014' N 87.657' E -7.702' N 82.158' E 34.827' N 93.213' E 48.737' N 122.925' E 20.235' 7 3 3 3 9 8 10 1112 13 N 16.044' E -221.326' N 7.389' E -87.710' N -54.256' E -165.904' 14 15 15 15 16 17 16 18 18 16 18 18 19 20 21 22 SHEET NO: REVISIONS: DRAWING TITLE: PROJECT: CHECKED: DRAWN: DATE:b10100 Lone Tree DriveAnchorage, Alaska 99507Studio2 A1.1 PLOT PLAN 2018-1 BAB BAB 8/23/18BURKHART RESIDENCEPROSPECT HTS. ADDN. NO. 2ANCHORAGE, ALASKA1" = 30'-0"1 PLOT PLAN PLOT PLAN NOTES MOA GRID SW25401.DATE OF SURVEY: FEBRUARY 13, 2018. 2.TOPOGRAPHIC CONTOURS & BASIS OF VERT. DATUM SHOWN ARE BASED ON PUBLISHED MOA LIDAR MAPPING DATABASE INFORMATION, TYP. 3.CONSTRUCTION COORDINATES SHOW NORTHING & EASTING FROM CONSTRUCTION COORDINATE CONTROL POINT, TYP. - ESTABLISHED @ FOUND 5/8" REBAR @ END OF CURVE ON SCHUSS DRIVE. 4.EXISTING TOPOGRAPHY / DRAINAGE GRADES ARE LABELED IN GREY TEXT. NEW TOPOGRAPHY / DRAINAGE GRADES ARE LABELD IN BOLD BLACK TEXT. 5.(N) WELL LOCATION. 6.(N) INSULATED WATER SERVICE LINE FROM WELL. 7.(E) SEPTIC SYSTEM PERC TEST HOLE. 8.30' SEPTIC SYSTEM TEST HOLE RADIUS. 9.100' WELL SEPARATION RADIUS. 10.(N) 1,000 GAL. SEPTIC TANK. 11.(N) 45' LONG x 5' WIDE x 3' EFFECTIVE ABSORPTION TRENCH. 12.ALTERNATE ABSORPTION TRENCH. 13.(N) BLDG. SEWER LINE TO (N) SEPTIC TANK. 14.(N) 6' H CHAIN LINK FENCE, TYP. 15.(N) 4' X 6' CONC. STOOP. 16.(N) ROOF OVERHANG -VARIES 1.5' TO 3.5'. 17.(N) ROOF OVERHANG -2.0'. 18.(N) ROOF OVERHANG -2.5'. 19.(N) 7' X 8' EXT. WOOD DECK. 20.(N) 16.0' X 16.7' EXT. WOOD ENTRY DECK W/ VARYING ROOF EXTENSION. 21.(N) DRIVEWAY & APRON W/ AC PAVEMENT. 22.(N) 18" DRAINAGE CULVERT UNDER (N) DRIVEWAY W/ FLARED ENDS & CONSTRUCTED PER MOA DRIVEWAY STANDARDS & HANDOUT AG-23.8/23/18