Loading...
HomeMy WebLinkAboutDENALY ESTATES BLK 2 LT 7 Onsite File benaly Estates Block 2 Lot 7 #067 - 062 - 14 Municipality of Anchorage On -Site Water and Wastewater Program • (907) 343-79041 of 3 ON-SITE WASTEWATER INSPECTION REPORT NoV OSP181275 067-062-14 Permit Number: PID Number: 2019 Dwelling: 0 Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: 9 New ❑ Upgrade Name: Troy Davis Homes ABSORPTION FIELD ❑ Deep Trench El Shallow Trench Q Bed E] Mound Address 1689 Knik Goose Bay Rd 400 Wasilla, AK 99654 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 310-2501 4 1.2 GPD/SF 3.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 2.5 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot Denal Estate 2 7 y Fill added above original grade 1.7 Ft. Gravel length 38 Ft. Township Range Section Gravel width 21 Ft. Beds: Number of Lines 3 Distance between lines 7.0 Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 798 Ft2 Ft. Well >100' >100' N/A N/A >25' TANK I] Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 11,500 Gal. Surface Water >100' >100' N/A N/A Material Number of compartments Lot Line >5' 6'** N/A N/A Steel 2 NA Foundation >10' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Tank is insulated. A larger tank was Pump on level at in. Pump off level at in. High water alarm at in. installed to allow for extra settling capacity for solids from grinder pump in basement. Pump make and model Electrical Inspections performed by **See Lot Line Waiver. PIPE MATERIAL House to tank D3034 Tank to drainfield D3034 Installer Sanders & Sanders Drainfield D3034 CO/MT Inspector J. Williams BENCH MARK (Assumed elevation) 100 ft Inspetes: 15 11/27/18 11/28/18 Location and description 2nd 3`d 4th Bottom of siding @ point B. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp 14 Ia ........... Conditional Approval: Date ���P,..••°"" °49 h ° • ..{. t 0..t.....I....t...............(.....S................ ��n a MICHAEL E. ANDERSON .• v�"•, NO. CE -4387 : �'� �A®TC�,p`'°o, Approve- - Date 11/25/19 <��1 �� �+�'�®��� 4It"ROFESS inspection Keport—a-i-iz.00c DENALY ESTATES B2 L7 PERMIT # OSP181275 / / / / / \ / 15' T&E ASEMENT / \ TRACT B 38' LONG x 21' WIDE x.5' VACANIT\ EFFECTIVE DEPTH ABSORPTION BED \ ALTERNATE SITE: CATEGORY III SYSTEM W/ 20' LONG x 5' IDE x NO EFF. DEPTH ABSORP IQN \TRENCH. 6 GPD/SF APP. RAT 10' TRAIL ASEMENT WELL SERVICE LINE hyo I Z1,500 GALLON PTIC TANK / INTERIOR GRINDER PUMP/LIFT STATION /I I I I I \I I ` LOT 7 GE aHGiN[aaiNG I TH#10 P I D # 067-062-14 Ile y�F EXISTING WELL PLAN AS -BUILT 0 50 100 FEET V=50' Q5 TH#2 LOT 6 3116 /EXISTING WELL 10' DRAINAGE EASEMENTS / A B / FCO 2.2 18.?1 SV1 16.4 18 SV2 24.3 1 .7 2CO 34.6 8.0 MT1 52.1 42.9 C01 5 2. 5 43.8 CO2 55.8 48.7 CO3 59.8 54.3 MT2 61.E 56.1 MT3 3 .2 43.6 C04 9.9 43.0 C05 33.3 35.7 C06 27.9 29.0 MT4 23.1 25.9 LEGEND CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE CONTOUR INTERVAL -5' DENALY ESTATES B2 L7 PERMIT # OSP181275 95.7 PID # 067-062-14 99.91FINISH GRADE 98.2 ORIGINAL GRADE 95.2 38' GROUNDWATER @ 88.2 7/28/18 84.2 PROFILE AS -BUILT (NO SCALE) 95.2 INSULATION 95.7 .. OF �,. • •; # w 49th ".MICHAEL E. ANDERSON •••���f�.••... NO. CE -4381 .�*gam -J F 11/25/19 ,.• C`��� Wheaton Water Well, Inc. 1190 N. Wasilla-Fishhook Road Wasilla, AK 99654 (9071376-2041 Name: Troy Davis Homes Inc. Address: 1689 Knik Goose Bay Road, Suite 400 City: Wasilla State: AK Zip Code: 99654 Well Site: Denaly Estates Lot/Block: 7/2 Additional: 25322 McIntyre Road, Eagle River, AK Well Depth: 133 ft From: To: Formation: 0 17 sand & gravel Below Ground: 131 ft 17 49 silt & gravel Above Ground: 2 ft. 49 70 silt Gal/Min: 30 70 111 wet sticky clay 111 130 wet sticky clay & gravel Static Level: 0 ft 130 133 gravel & water Casing: 133 ft. of 6 in. x .25 in. steel Liner Pipe: N/A Screened: N/A Perforated: N/A Grouted: Bentonite Depth: 20' plus WATER qUALITY TESTING Develop. Method: Air COIL Pn a C01/900ML Nitrates d 2? mg/L Use of Well: Residential ArSeNc (2S ug/L Drilling Method: Rotary - Misc: Flowing Artesian Other: well disinfected with chlorine 50 ppm 7 bags of chips The well was pumped 5' off the bottom with 100% draw down for hours and recovered at 30 gpm. Date Drilled: -2 9/10/2018 Driller: Ben Mattson Pump Installation Date: No Submersible Pump. Pump Intake Depth Below Top of Well Casing: feet Pump Manufacturer's Name: Pump Model: Pump Size hp Pitless Adapter Burial Depth: 12 feet Pitless Adapter Manufacturer's Name: Campbell Pitless Adapter Installer: Well Disinfected Upon Completion? ❑ Yes ❑ No Method of Disinfection: Comments: Artesian well. Jet pump installed in house Pump Installer Name: No well pump installed Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Mark Begieh Anchorage, AK 99507 Mayor www.muni.org/onsite (907) 343-7904 Pump Installati®n L® Well Drilling Permit Number: SW Date of Issue: Parcel Identification Number: Legal Description Property Owner Name & Address: Denaly Lot 7, Block 2 Troy Davis Homes Inc 1689 Knik Goose Bay Rd Wasilla, AK. 99654 Pump Installation Date: No Submersible Pump. Pump Intake Depth Below Top of Well Casing: feet Pump Manufacturer's Name: Pump Model: Pump Size hp Pitless Adapter Burial Depth: 12 feet Pitless Adapter Manufacturer's Name: Campbell Pitless Adapter Installer: Well Disinfected Upon Completion? ❑ Yes ❑ No Method of Disinfection: Comments: Artesian well. Jet pump installed in house Pump Installer Name: No well pump installed Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. oolf:;l • o Op I� N Q: O•• ,aoo b N 0, aL.L; _ ,2 ���; NPA�Uj Opp��••� :Y ...�Qao co E Y ° O a a Q O X 0 �°iEm o °opo o mo m o E worn a n c o 0 to't +SLS Q ma I I o_ N �NNaO 46 ',:F O G-0. m+hNa N ^ 00te°, � 0.0�OOO Oornmoocom Y w°oE cao -o no+ coo mm E z a U i m'_o� m_coco e 0 0+ 0 M o C O % 0 1 L V U p c cc p wom�+oi °o o ma � 6 o. taj � muoa.c � vo O } (nNoma3a 00 090 w C _ a w a 0 S a XI �(� p�a00 E6 Ca J_ '^O 7 N J >aJU 0go 0.0't ; _0 a N �( LWp OLE,0 `l p OO Q �C 0:E 0' l V =220 = N mmznEco w 00 Vi 2 CL `� �,�OtEac s m m O O O L mJLcEEm m am :E o• J L <3cao a scot • it n r S. • Municipality of Anchorage P.O. Box 196650 1 4700 Elmore Road Anchorage, Alaska 99519-6650 ® (907) 343-7904 ® Fax (907) 343-7997 http://www.muni.orq/Onsite Development Services Department On-Site Water and Wastewater Section **** VARIANCE/WAIVER REVIEW *x x x Waiver#: OSV181062 COSA#: Permit#: OSP181275 PID#: 067-062-14 Legal Description: Denaly Estates Block 2 Lot 7 Engineer: Forge Engineering Applicant: Troy Davis Homes Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 1.0 feet. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: Date: g/20/1 Approved by: kittietA Name of Reviewer **** VARIANCE/WAIVER REVIEW **** goblii,„„„, ,„, " 9 70 77, MUNICIPALITY OF ANCHORAG ^ RUSH! X AUG 1a 2013 6 Community Development Department 1 Phone: : " 343-7904co Development Services Division Fax: 9 1 i .- •• s"A On-Site Water & Wastewater Program 6 8 L9 ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 067-062-14 L , J Property owner(s) Troy Davis Homes Day phone 310-2501 Mailing address 1689 Knik Goose Bay Rd #400, Wasilla, AK 99654 Site address 25322 McIntyre Rd. Chugiak, AK 99567 Legal description (Sub'd., Block & Lot) Denaly Estates, Block 2, Lot 7 Legal description (Township. Range & Section) Lot Size 71,055 Sq. Ft. Number of Bedrooms Four (4) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (EI all that apply) Absorption Field ❑X Initial (� Single Family (SF) (X1 (w/wo ADU) Septic Tank ❑X Upgrade ❑ Duplex (D) Holding Tank ❑ Renewal Multiple Dwellings H Privy (SF and/or D) Private Well AtS Water Storage THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Lot Line Waiver Distance: 1' I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. LL a,..-..k-— (Signature of property owner or authorized agent) Permit/Rush Fees: t (2 1., 70 Waiver Fees: 3411,66 Date of Payment: 1119" !d Date of Payment: g 11'4-0 Receipt Number: 655531) Q553513Receipt Number: Q� Permit No. OSP 12/ 76- Waiver No. 05'11'3 lOa Permit App_ c d�M GE INGINIERING PO BOX 240773 ANCHORAGE,AK 99524 522-7773 677-7766(FAX) August 16, 2018 MOA Development Services Dept, On-Site Water& Wastewater Program 4700 Elmore Rd Anchorage,AK 99507 Subject: Denaly Estates Block 2 Lot 7—25322 McIntyre Road Septic System Design and Permit Application Dear On-Site Services Engineer: The developer of the subject lot intends to construct a 4-bedroom home on the property. We are submitting this design and permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home and the proposed well, septic location and alternate site.No conflicts exist between this proposed system and any other well or septic system,whether on this lot or adjacent lots. The ground surface on the lot slopes moderately to the south. Ground contours are shown on the site plan showing the grade and direction of flow. Storm water drainage will not impact this septic system. The new beds will be constructed parallel to the slope as much as possible. The adjacent lots remain vacant and undeveloped. The new septic system will be a minimum of 100' from all wells and surface water, and more than 5' from the septic tank. The alternate site is located more than 10' from the primary site. The beds will be 1' from the northwest lot line at the closest point. Please refer to the attached test hole logs, laboratory gradations and plan and profile sheets for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, n``�‘‘ *: 49jTH %It Michael E. Anderson, PE �7 4. -�. 6��r chae4l 438 Anderson '���/ Attachments ,,,/o'1<c9,4-g.%(_•,*V� t, ��D�CfES 10tiP� A V) ' GE ENGINEERING PO BOX 240773 ANCHORAGE,AK 99524 522-7773 677-7766(FAX) August 16,2018 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program P.O. Box 196650 Anchorage,AK 99519-6650 Subject: Denaly Estates Block 2 Lot 7—25322 McIntyre Road Separation Distance Waiver Absorption Bed to Lot Line Dear On Site Services Engineer: A section of the proposed absorption bed on the subject lot must be placed at 1' from the northwesterly lot line due to the proximity of the proposed house on the lot and the presence of shallow groundwater. The majority of the bed system is more than 4' from the property line. Soil conditions at this location are composed of clean sand with silt with percolation rates under 1 minute per inch. Very little migration of effluent is anticipated. The adjacent lot is undeveloped with substantial surface area for a septic system. We therefore request a waiver be issued allowing the trench to be 1' from the lot line at its closest point. Sincerely, E Michael E. Anderson, P.E. ?`?."41 .• 49•�th f‘��....• • Yownmm.n /• 1,MICHAEL•E. ANDERSON /�/ . Zvi ••s NO. CE-4381 at 441 •,,_,\\\S\•�:;•• MUNICIPALITY OF ANCHORAGE �7&9f. 4.ealk DEVELOPMENT SERVICES DEPARTMENT /'eQ9.• ��� •9*Ft 1,+ 1+700 ELMORE ROAD ANCHORAGE, AK 99519-6650 A*:��)TTM� ' •*/// SOILS LOG AND PERCOLATION TEST // •. Michael E.Anderson; /fib• epi.01t-i .*�-E „ �/ LEGAL DESCRIPTION: DENALY B2 L7 i, ROFESSIO .r PERFORMED FOR: TROY DAVIS ANN "%lig! DATE: 7/03/18 PROJECT No.: Professional Engineers Stamp: PARCELID#: 067-062-14 TECHNICIAN: J. MILLETTE DEPTH TEST HOLE l (feet) SLOPE 1 �, .- 1' OLSITE PLAN SANDY GRAVEL(GW) 3 ;.: 4 :t: . 5 SEE SITE PLAN 1 6SAND W/SOME SILT (SP) 1 7 8 9 ., Q %// WAS GROUND WATER ENCOUNTERED? YE S 1 0 IF YES n WHAT DEPTH? 9' S DEPTH OF WATER AFTER MONITORING: 10 I I DATE OF MONITORING: //28/18 12 BROWN SILT(ML) DEPTH To 13 DATE READING GROSS TIME E NET TIMESWATER NET TCDROP (INCHES) 14 7/6 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 1 12:45 0:05 4"/ 10" 6" 16 2 12:45 0:06 4"/10" 6" 3 12:46 0:07 4"/10" 6" 17 18 19 20 PERCOLATION RATE:.02 (MIN/INCH) PERC.HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 3 FT. and 4 FT. COMMENTS: r NORTHERN GEOTECHNICAL ENGINEERING,INC./ TERRA FIRMA TESTING i-t-p6. � L .--_ . L: r/ Laboratory Testing Geotechnical Engineering Instrumentation Construction Monitoring Services Thermal Analysis PROJECT CLIENT: Forge Engineering %GRAVEL. 10.6 USCS SP PROJECT NAME: Denali %SAND 87.2 USACOE FC N/A PROJECT NO.: 4914-18 %SILT/CLAY 2.2 %PASS.0.02 mm N/A SAMPLE LOC.: TH-1 %MOIST.CONTENT 3.9 %PASS.0.002 mm N/A NUMBER/DEPTH: Lot 7 UNIFORMITY COEFFICIENT(Cu) 5.4 DESCRIPTION: Poorly-graded send COEFFICIENT OF GRADATION(Cc) 1.0 DATE RECEIVED: 7/11/2018 ASTM D1557(uncorrected) N/A TESTED BY: CH ASTM D4718(corrected) N/A REVIEWED BY: RJPC OPTIMUM MOIST.CONTENT.(corrected) N/A PARTICLE SIZE ANALYSIS ASTM D422 I C I36 U (KM I U.S.SIEVE.NIRAfF.Rs I HYDROMETER SIEVE ANALYSIS RESULT IOD - 6 3 • 3/1 V23r18 H N10 Nm N13 10'Jr .2CJ •• 2 SIEVE SIEVE TOTAL% SPECIFICATION 90 . , , SIZE(aim) SIZE(U.S.) PASSING (%PASSING) 80 i 152.40 6" 70 • _ 76.20 3" �__-- 38.10 1.5" 100 �• 60 -- -#_--._.....__.._. 19.00 3/4" 99 50 - - - 12.70 1/2" 98 al 9.50 3/8" 96 41 4.75 #4 89 oG -- 2.00 #10 71 30 I 0.85 #20 39 w 20 1 ` -- 0.43 #40 17 ! 0.25 #60 7 10 ' 0.15 #100 4 0 E • 4R 0.075 #200 2.2 100 10 1 0.1 0.01 0.001 GRAIN SIZE(mm) IIYDROME"i'ER RESULT ELAPSED DIAMETER TOTAL% ICOBBLES I GRAVEL SAND I SILT or CLAY I TIME(MIN) (mm) PASSING Coarse Fine Coarse Medium Fine 0.5 • 1 MOISTURE-DENSITY RELATIONSHIP ASTM D1557 2 4 145 —_ --- - I s I .. _. '1 .. .--.——. __ _ 15 140 , — �� _T— 30 60 135 _ _-._-. 250 - -- - - -. 1 1440 Z• 130 — -~ HYDRAULIC GOND. N/A o -' (ASTM D2434) • 125 - Q - DEGRADATION N/A • 120 —-----.. (ATM 1-313) __ _ {{ PLASTICITY INDEX N/A 115 ---— -- f ASTM 4318 0 2 4 6 8 10 12 14 16 MOISTURE CONTENT(%) The testing services reported herein have been performed to recognized industry standards,unless otherwise noted No other warranty is made. Should engineering interpretation or opinion be required,NGE-TFT will provide upon written request. 11301 Olive Lane • Anchorage,Alaska 99515 • Phone:907-344-5934 • Fax:907-344-5993 • www.nge-{.coin r-. NORTHERN GEOTECHNICAL ENGINEERING,INC./ TERRA FIRMA TESTING 4110, ILLaboratory Testing Geotechnical Engineering Instrumentation Construction Monitoring Services Thermal Analysis PROJECT CLIENT: Forge Engineering %GRAVEL 1.1 USCS ML PROJECT NAME: Denali %SAND 30.6 USACOE FC N/A PROJECT NO.: 4914-18 %SILT/CLAY 68.3 %PASS.0.02 mm— N/A SAMPLE LOC.: TH-1 %MOIST.CONTENT 21.1 %PASS.0.002 mm N/A NUMBER/DEPTH: Lot 7/9'-14' UNIFORMITY COEFFICIENT(Ca) UNKNOWN DESCRIPTION: Sandy slit COEFFICIENT OF GRADATION(Ca) UNKNOWN DATE RECEIVED: 7/11/2018 ASTM D1557(uncorrected) N/A TESTED BY: CH ASTM D4718(corrected) N/A REVIEWED BY: RJPC OPTIMUM MOIST.CONTENT.(corrected) N/A PARTICLE SIZE ANALYSIS ASTM D422/C136 US.SIEVE ornate°nM Noes I Un.SIEVE NUMBERS 1 HYDROMETER SIEVE ANALYSIS RESULT 6 I 1.5 361 n3 L! 44 MO IM 0 AGO 4140 Y 100 ' ' • ♦♦ ♦ ♦ ' 1 J SICVIO SIEVE `rOTAL% SPECIFICATION 90 SIZE(nun) SIZE(U.S.) PASSING m,PASSING) 80 - - 152.40 6" 70 _.._._._._ . 76.20 3" - 38.10 1.5" Tn 60 - 19.00 3/4" 100 50 , . 12.70 1/2" 99 9.50 3/8" 99 Goo 40 - — 4.75 #4 99 PI , 2.00 #10 98 30 0.85 #20 97 20 0.43 #40 96 _ �_..__-_ ___ 0.25 #60 93 10 - 0.15 #100 87 0 _ �— — 0.075 #200 68.3 100 10 1 0.1 0.01 0.001 GRAIN SIZE(mm) HYDROMETER RESULT GRAVEL SAND ELAPSED DIAMETER TOTAL% I COBBLES( 1 SILT or CLAY ( TIME(MIN) (mm) PASSING Coarse Fine Coarse Mcde m Fine 0.5 1 MOISTURE-DENSITY RELATIONSHIP ASTM D1557 2 4 145 _--_ 8 _ -- �`- — -__ 15 140 ---.._--...-_ -- 30 - _ -- 60 250 .S 135 1440 > - - l~ x 130 HYDRAULIC COND. A (ASTM D2434) N/A A 125 _ — DEGRADATION (ATM T-313) N/A 120 _ - PLASTICITY INDEX N/A _ — ASTM 4318 115 0 2 4 6 8 10 12 14 16 MOISTURE CONTENT(%) The testing services reported herein have been performed to recognized industry standards,unless otherwise noted. No other warranty is made. Should engineering interpretation or opinion be required,NGP-TFT will provide upon written request. 11301 Olive Lane • Anchorage,Alaska 99515 • Phone:907-344-5934 • Fax:907-344-5993 - Tvww.nge-tfLcom MUNICIPALITY OF ANCHORAGE ~,�(G9 . 4‘l], DEVELOPMENT SERVICES DEPARTMENT e. *trook,4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 % • &:_o'-� • SOILS LOG AND PERCOLATION TEST %r-... Michael E.4§3,1-E .4,-,.../.I LEGAL DESCRIPTION: DENALY B2 L7 t'l��F OFESSO ��+r PERFORMED FOR: TROY DAV I S Professional Engineers Stamp: DATE: 7/03/18 PROJECT No.: PARCEL ID#: 067-062-14 TECHNICIAN: J. MILLETTE DEPTH TEST HOLE 2 (feet) I 1' OG SLOPE SITE PLAN 1 7 BROWN SILT(ML) 2 3 .1: t ,f 4 ': $�'• 5 • S'1 sI H 1'!,:N 6 ''' ' t 7: t`. SAND W/SOME SILT(SP) 'i 7 '. :10 ' ?:y=.`' 'i''.:::::;••.‘1.1.;:.; :•: WAS GROUND WATER ENCOUNTERED? NO '` + IF YES r:WHAT DEPTH? - S 1 I .. DEPTH OF WATER AFTER MONITORING: 11' :i1�c�'`'' Z DATE OF MONITORING: 7/28/18 12 "`;'j� .^•R DEPTH To : :7' ' DATE READING GROSS TIME NET TIME NEATER NET DROP 13 „^'::.•: :: :7f: ^' (MINUTES) (MINUTES) (INCHES) (INCHES) 14 7/6 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 1 13:10 0:06 4"/10" 6" 2 13:11 0:05 4"/10" 6" 16 3 13:11 0:07 4"/ 10" 6" 17 18 19 20 PERCOLATION RATE: .02 (MIN/INCH) PERC.HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 3 FT. and 4 FT. COMMENTS: NORTHERN GEOTECHNICAL. ENGINEERING,INC./ TERRA FIRMA TESTING Ilk ,,/ Laboratory Testing Geotechnical Engineering Instrumentation Construction Monitoring Services 'Thermal Analysis PROJECT CLIENT: Forge Engineering _ %GRAVEL 13.2 USCS SP PROJECT NAME: Denali %SAND 85.6 USACOEFC N/A — PROJECT NO.: 4914-18 %SILT/CLAY 1.2 %PASS.0.02 mm N/A SAMPLE LOC.: TH-2 %MOIST.CONTENT 6.6 %PASS.0.002 mm N/A NUMBER/DEPTH: Lot 7 UNIFORMITY COEFFICIENT(Ce) 5.6 DESCRIPTION: Poorly-graded sand COEFFICIENT OF GRADATION(Ce) 0.9 DATE RECEIVED: 7/11/2018 ASTM DI557(uncorrected) N/A TESTED BY: CH ASTM D4718(corrected) N/A REVIEWED BY: RJPC OPTIMUM MOIST.CONTENT.(corrected) N/A PARTICLE SIZE ANALYSTS ASTM D422/C l36 U S.SIEW.WNW IN INTOES I Mt SIEVE NUMBERS F Fm,ROWEI FR SIEVE ANALYSIS RESULT 6 f li5 TI 7It I. 13 MIO M10 #t) or Ingo Or 1Q0 •* l 1 SIEVE SIEVE TOTAL% SPECIFICATION 90 SIZE(inn') SIZE(U.S.) PASSING (%PASSING) 80 ' ' _ 152.40 6" 70 • 76.20 3" 38.10 1.5" N 60 •' 19.00 3/4" 100 50 - . 12.70 1/2" 97 ---- -- —__ __•_ 9.50 3/8" 95 co 40 • - ,. 4.75 #4 87 ic4 30 — 2.00 #10 71 1 0.85 #20 39 IA., 0.43 ff40 21 20 i 0.25 #60 7 10 0.15 #100 2 — — 0 ♦ 4 - 0.075 #200 1.2 ' 100 10 1 0.1 0.01 0.001 GRAIN SIZE(mm) HYDROME'T'ER RESULT GRAVEL SANT) ELAPSED DIAMETER TOTAL% ICOBBI,ESI SILT or CLAY I •nME(MIN) (mm) PASSING Coarse Pira Coarse Medium Pino U 0.5 l —T MOISTURE-DENSITY RELATIONSHIP ASTM D 1557 2 4 145 8 _ -- — — --- 15 140 —�--_.�..—.—.—-------- 30 60 a135 - 250 — — —— — — — 1440 w 130 — HYDRAULIC COND. N/A A (ASTM D2434) A _125 DEGRADATION N/A 120 — (ATM T-313) — PLASTICITY INDEX N/A 1(5 ASTM 4318 0 2 4 6 8 10 12 14 16 MOISTURE CONTENT(%) The testing services reported herein have been performed to recognized industry standards,unless otherwise noted. No other warranty is made. Should engineering interpretation or opinion be required,NGE-TFT will provide upon written request. 11301 Olive Lane • Anchorage,Alaska 99515 • Phone:907-344-5934 - Fax:907-344-5993 • www.nge-1fi.com Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section - Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 067-062-14 1. GENERAL INFORMATION Complete legal description Location (site address) Expiration Date: 7 ^C1 -a c) ?' o Denaly Estates, Block 2, Lot 7 25322 McIntyre Road Chugiak, AK Current property owner(s) Troy Davis Homes, Inc. Day phone (907) 357-9394 Mailing address 1689 S. Knik Goose Bay Road #400, Wasilla, AK 99654 Real estate agent 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 Day phone 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well Private Septic ED Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 96^1 Date of Payment I W'26 Receipt Number O [ U35 -D COSA # 66 (^In Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering Phone 907-522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage AK 99503 Engineer's Printed Name Michael E. Anderson, P.E. Date 12/31/19 6. DSD SIGNATURE System #1 Approved for bedrooms System #2 Approved for bedrooms Disapproved °.,12/31/19 r �oaaOFCSS qP Conditional approval for bedrooms, with the following stipulations: .rt,tad46t!(r<�if�.�s. A to O.;,3) ,w))) By: Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet X14 Legal Description: Denaly Estates, Block 2, Lot 7 If more than 1 septic system on lot: COSA Checklist # A. WELL DATA OR Well log is filed with Onsite (or attached) Date drilled 9/10/18 Total depth 133 ft Cased to 133 ft ❑ Sanitary seal is functioning correctly Al Wires are properly protected Casing height (above ground) '24 in. Date of flow test for COSA 9/10/18 Static water level at beginning of test 0 ft. Comments Artesian Well. B. TANK DATA Age of tank(s) <1 years Tank type/material Septic/Steel Measured operating fluid level in septic tank ❑ Standpipes/foundation cleanout per record drawing Date of pumping New Construction D. ABSORPTION FIELD DATA Absorption Bed Which system tested (date installed) 11/28/18 ❑ ALL standpipes present per record drawing Total measured depth from grade 4.7 ft (max) Measured depth to pipe invert from grade 2.5 ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective Parcel ID: 067-062-14 of Structure served by this system Well production at time of test 30 gpm Water storage tank volume 0 gallons Well disinfected for coliform test? ❑ Yes ❑ Nc ❑ Coliform bacteria is Negative Nitrate •0280 mg/L ❑ Nitrate less than MRL (ND) Arsenic .125 ug/L ❑ Arsenic less than MRL (ND) Collected by Wheaton Water Well Date of Sample 10/23/19 C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: Adequacy test date New Construction Results ❑ Pass For bedrooms Fluid depth prior to test in Water added gal New depth in Elapsed time min ❑ Code -required soil cover over field Final fluid depth in ❑ System presoaked Absorption rate gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) _ date of test) Gallons introduced gallons If yes, enter date Comments/Deficiencies: Septic System constructed 11/28/18 and only recently placed in service COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' 0 Yes if No Community Sewer Manhole/Cleanout > 100' Q Yes if No ft 0 Yes if No ft Neighboring Tank > 100' 0 Yes if No ft Private Sewer/Septic Line > 25' 0 Yes if No ft Absorption Field on Lot > 100' M Yes if No ft Holding Tank > 100' 0 Yes if No ft Neighboring Absorption Fields > 100' Yes if No Animal Containment > 50' 0 Yes if No ft 0 Yes if No ft if No ft F. ENGINEER'S COMMENTS Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' El Yes if No ft r7l Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' Q✓ Yes if No ft Surface Water> 100' El Yes if No ft Property Line > 5' 0 Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ✓❑ Yes if No ft Private Wells > 100' 0 Yes if No ft Water Main > 10' 0 Yes if No ft Community Wells > 200' 0 Yes if No ft Water Service Line > 10' M Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Yes if No ft If absorption field is under driveway comment below Property Line > 10' ❑ Yes if No 6* ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells > 100' U Yes if No ft Water Service Line > 10' El Yes if No ft Community Wells > 200' El Yes if No ft Surface Water > 100' 0 Yes if No ft F. ENGINEER'S COMMENTS *See Lot Line Waiver. G. ENGINEER'S CERTIFICATION OF� 4hs I certify that I have determined through field inspections and review ����P;.•••'•���� of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. .:� 49th c........uu.........nu...vmnn...........a' MICHAEL E, ANDERSON QJ J9GE-4381 1/7/20 .•«'" FC COSA Checklist yellow sheet p (J....... �����