Loading...
HomeMy WebLinkAboutDENALY ESTATES BLK 2 LT 9 Onsite File bencily Estates Block 2 Lot 9 #067 - 062 - 16 WheatonWater •, N. Wasilla-Fish •• 1• Wasilla, AK 99654 (907)376-2041 Name: Troy Davis Homes Address: 1689 S Knik Goose Bay Rd. #400 City: Wasilla State: AK Zip Code: 99654 Well Site: Denaly Lot/Block: L9/B2 Additional: Replacement Well Depth: 135 ft. From: To: Formation: 0 28 silt/gravel Below Ground: 133 ft. 28 118 silt soft Above Ground: 2 ft. 118 126 fine silty sand Gal/Min: 50+ /Flowing 25 126 128 silt/clay soft 128 130 hard clay Static Level: Artesian 130 135 gravel/water Casing: 135 ' of 6" steel casing Liner Pipe: N/A Screened: N/A Perforated: N/A f WATER QUALITY TESTING Coliform _ C01/900mll- Grouted: Yes, 6 bags Nitrates 6N7 mgJL I Arsenic . �S ug/L Depth: N/A Develop. Method: Air Use of Well: Residential Drilling Method: Rotary Misc: Flowing Artesian Other: Well disinfected with chlorine 50ppm The well was pumped 5' off the bottom with 100% draw down for 2 hours and recovered at 50+ /Flowing 25 . Date Drilled: 10/4/2019 Driller: Ben Mattson Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Elmore Road u P.O. Box 196650 Mark Begich Anchorage, AK 99507 s h F e T r Mayor www.muni.org/onsite (907) 343-7904 Pump Installation L® Well Drilling Permit Number: SW OSP Date of Issue: Parcel Identification Number: Legal Description Denaly Blk 2 Lot 9 Pump Installation Date: 10/10/2019 Pump Intake Depth Below Top of Well Casing: N/A Pump Manufacturer's Name: N/A Pump Model: N/A Pump Size N/A hp Pitless Adapter Burial Depth: N/A feet Pitless Adapter Manufacturer's Name: N/A Pitless Adapter Installer: Unknown Well Disinfected Upon Completion? ❑✓ Yes ❑ No Method of Disinfection: Sterilene feet Property Owner Name & Address: Troy Davis Homes, Inc. 1689 Knik Goose Bay Road #400 Wasilla, AK 99654 Comments: JET PUMP INSTALLED INSIDE THE HOUSE. NO PUMP IN THE WELL Pump Installer Name: Wheaton Water Well, Inc. 1190 N. Wasilla-Fishhook Road Wasilla, AK 99654 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pomp installation. O FZ� i iPs�MEN Z :;d- < ::D J Q 1 0 0 H Z Z W 0 C)>O~ / Z m Z 0 0 U _Z o -E_ _ oui p LL Q O W w 0 Z U , 275Cf) / W J O O OW 7-- � I=- OU N U \ / U a� fn j I— o oLLI ` O J n- �z \ � �L NW W \ Co C/) w �W j ~ \Z / W z // w W I- o o / J N�/ W O � LL f- D W a n �O( rn T O U 0- T CO U LL D O O O Q z 00 LU 10 WUJ �CL� 3: Q z > m W 0 (D O� �N 0Z� � o uja Q F f- W Z ; 2 W/ I F- W W o� 0-0 0 C:) r LO o ro :aa w t° of �W U c-, : if Cno e¢ Z Community Development Department On -Site Water and Wastewater Program 4700 Elmore St • P.O. Sox 196650 Anchorage, AK 99519-6650 - http:/Iwww.muni.org/onsite • (907) 343-7904 SubdIV,s1;n7)C-AVu Block 2- Lot 9 T R Section Lot On-site Water & Wastewater Program certified contractor performing the well decommission� Signature: Company: lA9 tivcr �SIy tcywe'RS Weil decommissioning date i i J I Method of decommissioning: AMC 15.55.0601-1 a. ❑ b. ❑ C. Location: Use the space below to provide a drawing of the property showing the following items: North arrow Decommissioned well, Other water wells on the property, Two separate swing -tie distances for each well shown on the dmwing, Note: The swing -tie distances shall be measured rrom either permanent structures or the property comers. I MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PQ Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water System Permit Permit Number: OSP191446 Work Type: Well Upgrade Tax Code Number: 06706216000 Site Legal Address: DENALY ESTATES BLK 2 LT 9 G:0362 Site Mailing Address: 25286 MC INTYRE RD, Eagle River Owner: VOJTA SARAH ANN & SCOTT A Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date: Expiration Date: s +� AV n v t)C17211't111E'�i1C Lot Size In: SclFt: Total Bedrooms: 10,/3/2019 10/2/2020 107658 ❑ Disposal Field CI Septic Tank ❑ Holding Tank ❑ Privy 0 Private WellQ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing pecial Provisions: To. close out this permit, please submit the following: 1. Well log 2. Pump install log 3. Water sample results for total coliform, nitrates and arsenic 4. Decommissioning log: for original well Received By: bK110 Issued By: Date: Date: 4 d EVIUNICIPALITY OF � A Community Development Department Phone: 907-343-7904 Development Services Division Fax: 90 -9 a On -Site Water & Wastewater Program ,�u ll I ON-SITE SEWER/WELL PERMIT APPLICATION a OCT 0 2 20119 n 3 Parcel I.D. 067-062-16 3 ; SoP Property owner(s) VOJTA SARAH ANN & SCOTT A Day phone 31 `- a C�" Mailing address PO Box 111155 Anchorage AK 99511 Site address 25286 McIntyre Rd. Chugiak, AK 99567 Legal description (Sub'd., Block & Lot) Denaly Estates Block 2 Lot 9 Legal description (Township, Range & Section) Lot Size 107,658 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) ❑X ADU) Septic Tank ElUpgrade FK(w/wo Duplex ElHolding (D) Tank 1-1Renewal ElMultiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑x Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 4 3(Qb Waiver Fees: Date of Payment: 1013119 Date of Payment: Receipt Number: MU Q0 Receipt Number: Permit No. O SP O IL114 o Waiver No. Permit App__- : . _.,:c PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) October 2, 2019 MOA Development Services Dept, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Denaly Estates Block 2 Lot 9 – 25286 McIntyre Rd New Well. Dear On-Site Services Engineer: The owner of the above lot is experiencing some severe sediment issues with their well. The lower portion of the well is full of silt and sand and cannot be cleaned out due to the fact that it is artesian, so we are submitting this permit application for the construction of a new well in a new location. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this new proposed well and any other septic system, whether on this lot or adjacent lots. Wells on this and adjacent lots are shown. The new well will be a minimum of 100’ from all septic systems. Please refer to the attached plan for anything concerning the new well location. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Michael E. Anderson, PE 10/2/19 DENALY ESTATES, BLOCK 2, LOT 9 PERMIT # OSP181259 \ EOS 1p SEPTIG AREA TAI FROM SURVEY LOT 1 OSED NEW I WELL L ION ALTERNAIE SITE: CATEGOR"l SYSTEM \H 5' WIDE��Q',LONG ABSO-2PTI0 TRENCH. APf�RATE 6 GPD \ 1,250 GALC �1 SE IC TAN 2x60' NG x 5'WIDE x.5' \ FLOW SPUTTER \\ E ECTIVE DEPTH \I SORPTION TNCHES W/ 2' ��� \i 20 M.O.A. APP VED SAND CO2_ LOT 9 M C04 _ e TH3 PID # 067-062-16 1 0' ELL RADII- � 7XISTI ELL \ DECOMMISSIONED i '•• 49th• •' r MICHAEL E. ANDERSON •, 4 NO. CE -4381 I��c� '•..• 10/2/19Us ,,.•'•c���� LOT 8 -,,-,,VACAN' NOTE: ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. 0 50 100 klFEET ENGING 1 "=50' FCO 3.8 30.4 SV1 18.7 35.6 SV2 26.8 40.5 2CO 30.6 43.9 C01 52.3 38.4 CO2 1 61.4 79.2 MT1 63.5 80.8 CO3 68.7 55.7 C04 77.0 89.8 MT2 74.7 88.0 LEGEND CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE CONTOUR INTERVAL -4' Municipality of Anchorage:{' 3 . ' On -Site Water and Wastewater Program • (907) 343-7904 , ale .� 1�`�0 3 ON-SITE WASTEWATER INSPECTION REPOR FEB 2 5 2019 Permit Number: OSP181259 PID Number: 067-062-16 Dwelling: ❑I■ Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: 0 New ❑ Upgrade Name: Troy Davis Homes ABSORPTION FIELD ❑ Deep Trench 0 Shallow Trench ❑ Bed ❑ Mound Address 1689 Knik Goose Bay Rd 400 Wasilla, AK 99654 ❑ Other Phone Num ber of Bedrooms Soil Rating Total depth from original grade 310-2501 4 1.0 GPD/SF 4.0/3.8 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 3.5/3.3 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot Denaly Estates 2 9 Fill added above original grade 0-0/0.2 Ft. Gravel length 2 @ 60 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 600 Fe 2 >6 Ft. Well >100' >100' N/A N/A >25' TANK ❑p Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 1250 Gal. Surface Water >100' >100' N/A N/A Material Number of compartments Lot Line >10' >10' N/A N/A Steel 2 NA Foundation >10' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks *Tank and line from house to tank are Pump on level at in. Pump off level at in. High water alarm at in. covered with 2" of insulation. Pump make and model Electrical Inspections performed by Installer PIPE MATERIAL House to tank D3034 Tank to drainfield D3034 Northern Excavation Drainfield D3034 CO/MT Inspector J. Millette BENCH MARK (Assumed elevation) 100 It Inspectes: 1tion5' 10/05/18 10/06/18 Location and description 2nd 3`d 4th Top Block on West Wall of House. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Conditional Approval: Date ""'�.S�•+ •�P�'aAmp o ! 49th iA' .........,.� . •• MICHAELMbERSON •;�Zia No. cE-4381 7Z�741111` Appro r Date 2/25/19 •,r•'��C'` ���t�aewwr►�a Inspection Keport_9-1-12.doc I / H ::D LO O F-- Z r}- Z d O JW S co Z U m W Z f- d / OZ ZLU W / W Q W W J F- J } D� O O U m Z > W O O Z Z / CD O CL U) Z:) J p W d W W 0 cn E- H LLJ w O=i Ip Upoco C.) l3) LO 00 n U) r tJ)^ O CO LO m r}- N co ti 00 C) O OLOO > C> CD m 6 L C7i Ip V' Cl) t-- CC) LO OO c0 �nCO C.O C•i d' LOO - Or - 0o <.0 C14 Q ch N Lo - Q0 M C0 00 c0 t- titi ".Z3 - Or -NO <-N.-M'zl- 0 0 0 L N 0 l3) LO 00 n U) r tJ)^ O '�l MFSJ`iAW� r ` _w n U 'M O > _ '�l MFSJ`iAW� 94.1 93.6 94 93. DENALY ESTATES, BLOCK 2, LOT 9 PERMIT # OSP181259 PID # 067-062-16 o �- TRENCH #1 0 U� U GROUNDWATER @ 86.6 - 9/30/18 85.6 I-- TRENCH #2 o F- o rlS n� r` ri 1. II nl I nn Anrl INSULATION 94.1 60' PROFILE AS -BUILT NO SCALE ENGI NEEAING ( ) 1.1 Keaton Water Well, Inc. 1190 N. Wasilla-Fishhook Road Wasilla, AK 99654 (907)376-2041 Name: Troy Davis Homes Inc. Address: 1689 Knik Goose Bay Road, Suite 400 City: Wasilla State: AK Zip Code: 99654 Well Site: Denaly Lot/Block: L9 / B2 Additional: 25286 McIntyre Rd, Eagle River Well Depth: 141 ft. From: To: Formation: Below Ground: 139 ft. 0 5 gravel 5 zs silt &gravel Above Ground: 2 ft. 18 24 wet silt & gravel, brown Gal/Min: 20 24 37 silt & gravel, brown 37 66 dry silt, gray Static Level: 0 ft 66 108 wet sticky clay 108 111 silt, sand, water Casing: 141 ft. of 6 in. x .25 in. steel 111 134 wet sticky silt 134 136 gravel & water, 30 GPM, dirty Liner Pipe: N/A 136 139 silt 139 141 gravel & water Screened: N/A Perforated: N/A Grouted: Bentonite Depth: 20' plus Develop. Method: Air Use of Well: Residential - Drilling Method: Ratary i1�AT�Fa Q �T1N� Misc: CDlifiorm Flowing Artesian NftrateS ^� 0 Z g .~ $. Other: well disinfected with chlorine 50 ppm Arsenic � 6 bags of chips The well was pumped Y off the bottom with 100% draw down for 2 hours and recovered at 20 gpm. Date Drilled: 9/8/2018 Driller: Ben Mattson Development Services Department Buildin _q Safety Division A=e On -Site Water & Wastewater Program . . . . . . . . . . . . . 4700 Elrnore Road P.O. Box 196650 Mark Begich Anchorage, AK 99507 Mayor www.muni,org/onsite (907) 343-7904 Pump Installation Log Well Drilling Permit Number: SW_ Date of issue: Parcel Identification Number: Attention: The pump installer shall provide a purnp, installation 101g, to the DSD within 30 days of pump installation. MUNICIPALITY OF ANCHORAGE On-Site Water&Wastewater Program • ,5; • ate', PO Box 196650 4700 Elmore Road _ • ` Anchorage.Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 http://www.muni.org/onsite 44,CH;R I)epartinent On-Site Water & Wastewater System Permit Permit Number: OSP181259 Effective Date: 8/10/2018 Work Type: WellSeptic Initial Expiration Date: 8/10/2019 Tax Code Number: 06706216000 Site Legal Address: DENALY ESTATES BLK 2 LT 9 G:0362 Site Mailing Address: 25286 MC INTYRE RD, Eagle River Owner: TROY DAVIS HOMES INC Lot Size in Sq Ft: 107658 Design Engineer: FORGE ENGINEERING Total Bedrooms: 4 This permit is for the construction of: Q Disposal Field D Septic Tank 0 Holding Tank 0 Privy EI Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: The recorded plat for this subdivision notes that artesian wells are common and that special drilling methods may be required to prevent waste of water via surface discharge. Received By: (/ / /I / Date: • Issued By: feJ // 2 {.(',(A / / Date: g 0 /1 tic0.5: MUNICIPALITY OF ANCHORAGE r P ‘77if li 1 ca 5 6-1 I_ .1I Community Development Department .ri I ••i ene: 907-343-7904 Development Services Divisioncl`-� AUG 9 L01$ 'ax: 907-343-7997 On-Site Water & Wastewater Program It t lij*Ilkop, ON-SITE SEWER/WELL PERM 'ciN'PLICAT • Rust" / 0/ 680 arcel I.D. 067-062-16 Property owner(s) Troy Davis Homes Day phone 310-2501 Mailing address 1689 Knik Goose Bay Rd #400, Wasilla, AK 99654 Site address 25286 McIntyre Rd. Chugiak, AK 99567 Legal description (Sub'd., Block & Lot) Denaly Estates Block 2 Lot 9 Legal description (Township, Range & Section) Lot Size 107,658 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field AXI Initial X Single Family (SF) ❑X (w/wo ADU) Septic Tank X Upgrade I I Duplex (D) Holding Tank ❑ Renewal I I Multiple Dwellings n Privy (SF and/or D) Private Well Water Storage n THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 0/;,5-7-1q0 Waiver Fees: Date of Payment: gig fig Date of Payment: Receipt Number: CCM Ob Receipt Number: Permit No. DSP171 Waiver No. Permit App_:-:• ':..c; GE ENGINEERING PO BOX 240773 ANCHORAGE,AK 99524 522-7773 677-7766(FAX) August 9,2018 MOA Development Services Dept, On-Site Water& Wastewater Program 4700 Elmore Rd Anchorage,AK 99507 Subject: Denaly Estates Block 2 Lot 9—25286 McIntyre Rd Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system,whether on this lot or adjacent lots. The ground surface on the lot slopes moderately away from the road, at about a 5-15% slope. There are only a few short areas that are steeper than 25%,and the layout meets the slope criteria of section 15.65.210.B.1.e. Ground contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100' from all wells and surface water, and more than 5' away from the septic tank. The alternate site is located more than 16' away. Please refer to the attached test hole logs, soils lab analysis, plan and profile sheets for the septic design. If this design is followed,there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE *� 1N • �•••I •at , Benja hiller CE 12592 . �v'' 8/9/18 ! � f Cl) LAJ Lo 'y LLI 0 co LLJ LL: 1 Cl) 0 0 < CL U- LLJ C) < 0 X 102 0 2 LL. t '0 Z,:) X -j :2 Zco :2 X < <z x IL < z < z Q , LMLI 0 > () uj p z U,c a) W, 0 zLL U- 0 W z < < ry z C) w 02( 1 CO <LO < 10 z M: Lul F- 0, < ui > 0UZ 0 wm LifS< j l %t , / c0r) F-- LLJ LU LL - ME C) LO F - Z o W o w L.0 1 < ',-) I � 0 (1) F,- < ui D, ui I.,. 0 C) J O> < WOOZZF-�-ry n co :D LL 0 LU w 0 w CD 0 0 0 m I-- > Zo cn LU CIO LL co 0 0 F-- LLJ LU LL - ME C) LO CV Z o W w 0 0' w 6.. 3' 6" 6" 2' LOT 9 cc* , DESIGN E E. 600 GPD PEAK FLOW 5' WIDE TRENCH SYSTEM PERK RATE: <1 MIS!/IN 1,250 -GAL SEPTIC TANK APPLICATION RATE: 1.0 GPD/SF 2' M.O.A. APPROVED SAND 600 GPD / 1.0 GPD/SF / 5' WIDE * 1.0 RED. FACTOR= 120 LF TRENCH REQUIRED (120 LF SPECIFIED) BOTTOM OF TRENCH: 4' BELOW GRADE FLOW LINE ELEVATION: 3.5' BELOW GRADE TOP OF TRENCH: .5" ABOVE GRADE 0 EkG IH ££& I NG TYPICAL 5'WIDE SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 SOILS LOG AND PERCOLATION TEST LEGAL DESCRIPTION: DENALY ESTATES, BLOCK 2, LOT 9 PERFORMED FOR: TROY DAVIS HOMES DATE: 911Z,12018 PROJECT No.: PARCELID#: 067-062-16 TECHNICIAN: J. MILLETTE DEPTH TEST HOLE 3 (feet) I , 11 , Jill - Hill 1 O SLOPE 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 GRAVEL W/SAND & SILT GW t. READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH TO WATER (INCHES) WAS GROUI\TD WATER ENCOUNTERED? 9/14 Tr YES @ WHAT DEPTH? 11' DEPTH OF WATER AFTER MOINITOR-TNTG: It, 3:50 DATE OFT ONITORING: 9113M8 SEE SITE PLAN AW� ........... .......... Michael E. Anderson 483'-E DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH TO WATER (INCHES) NET DROP (INCHES) 9/14 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 3:50 .5 5/11 6 2 3:51 .5 5/11 6 3 3:52 .5 5111 1 6 4 1 3:53 .5 5/11 6 5 3:54 .5 5/11 1 6 6 3:55 .5 5/11 6 PERCOLATION RATE: .1 (MINANCH) PERC. HOLE "PEST RUN BETWEEN: 4 FT. and 5 FT, COMMENTS: See Laboratory Gradation. M.O.A. Approved Sand Filter Required. NORTHERN GEOTECHNIcAL ENGINEERING, INC..// TERRA FIRMA TESTING PROJECT CLIENT: Forge Engineering PROJECT NAME: Demli Estates PROJECT NO.: 4914-18 SAMPLE LOC.: TH-3 NUNIBE.W DE PTI -1: Lot 9 DESCRIPTION: 'vVell-graded gnivel w/ sand DATE. RECEIVED: 9/17/2018 TESTED BY: C11 RI VJE W ED BY: RJPC % GRAVEL 59.2 % SAND 38.3 % SILT/CLAY 2.5 % MOIST. CONTENT 2.9 USCS I USACOE FcL % PASS. 0.02 mm % PASS. 0,002 mm GW N/A N/A N/A UNIFORMITY COEFFICIENT (C,,) , mom 25'8 152.40 COEFFICIENT OF GRADATION (C,) 2 1.7 3" ASTI\4 D 1557 (uncorrected) 38.10 NIA I 100 1 ,ASTM D4718 (corrected) 3/41, NIA lj 12.70 [OPTEMUM MOIST. CONTENT. (corrected) N/A 1 9.50 PARTICLE SIZE ANALYSIS AS TM D422 / C136 u-&&laT.0?r.lmlG IN I NME-P4 I fmRommp, 6 3 1.5 94 11 Fic !6a , I , n2! 0200 lvv 90 80 70 foo 60 50 40 30 20 10 n I ll� 140 135 130 f >' 125 120 115 � "� TOTAL to SPhCIhICAkiON PASSING PA5SR G) N/A , mom 152.40 6" 2 76.20 3" �� 38.10 H�� 100 1 IBS 3/41, 86 12.70 �® 68 9.50 3/8" 58 4.75 4,14 41 i 2.00 #10 27 0.95 420 17 1 0.43 Y140 t1 j 0.25 1160 7 1 0.15 If 100 0.075 -#200 2.5 m 100 10 1 0.1 0.01 0.001 (3RMN SIZF (min) GIdAVEL SAND I SILT or CLAY I Coarse9---1 A MOISTURE—DENSITY RELATIONSMPASTM D1557 SIEVE ANALYSIS Ps SITU SIE-vr- SIZL(min) STEVE SME tU.S.) TOTAL to SPhCIhICAkiON PASSING PA5SR G) N/A 0.5 152.40 6" 2 76.20 3" 1 L N/A 38.10 1.5" 100 1 19.00 3/41, 86 12.70 1121, 68 9.50 3/8" 58 4.75 4,14 41 i 2.00 #10 27 0.95 420 17 1 0.43 Y140 t1 j 0.25 1160 7 1 0.15 If 100 0.075 -#200 2.5 HYD.REOME TER WULT ELAPSED DTAMETER TIME (MN) (-tn) (ASTM D2434) N/A 0.5 (ATM T-313) NIA 2 4 1 L N/A IS 30 60 250 HYDRAULIC COND. (ASTM D2434) N/A DEGRADATION (ATM T-313) NIA PLAS'T'ICITY INDEX ASTM 43 18 1 L N/A 0 2 4 6 8 10 12 14 16 moisnm coNTENT (�/.) The testhig services reported herein have been perfouned to recoViized industry standards, ut-dess othenvise noted. No other warranty is mv inteiprotationoropinioyibereqtiircd,NGE-TFTv,,iUpro,.idetiponwrittetircqticst 77301 Olive Lane - Anchoi-age, Alaska 99515 - Phone: 907-344-3934 - Fox. 907-344-5993 - lvivunge-tfhcon? MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT �c4%:. •. `4 * :f.91#1 � 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 0*.49TM )\ .* o� SOILS LOG AND PERCOLATION TEST •. Michael E.Anderson : N Y T �1+i'sjFp.474.� h•��� �% LEGAL DESCRIPTION: DE AL Es ATES, BLOCK 2, LOT 9 l` PROFESSION 4 PERFORMED FOR: TROY DAVIS HOMES kA�����~ DATE: 7/3/2018 PROJECT No.: Professional Engineers Stamp. PARCEL ID#: 067-062-16 TECHNICIAN: J. MILLETTE DEPTH TEST HOLE 1 (feet) 1' OB SLOPE SITE PLAN 3 ;::. 4 .._,, ,I•. 5 j.',.�y..,'f• SEE SITE PLAN 6 1 7 1,...;:;::-.;:::j.,-.I.. SANDY SILTY GRAVEL ••;:: :.1..-: GW8 1 ' 10 :,:i...,::;.;. WAS GROUND WATER ENCOUNTERED? NO ' ''`'` IF YES @ WHAT DEPTH? - S 1 1 DEPTH OF WATER AFTER MONITORING: 15.5' '..'••':.,'`;. DATE OF MONITORING:7/28/2018 12 ;::i;- - - ,H . DEPTH To ' '''' j=.':' DATE READING GROSS TIME NET TIME WATER NET DROP 13 => " (MINUTES) (MINUTES) (INCHES) � A-..; (INCHES) 14 .:. .*,:-:,..i 7/6 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 , .`•::•;...;:.,,! 1 11:20/11:21 1 4/10 16 2 11:22/11:23 1 4/10 6 3 11:25/11:26 1 4/10 6 17 4 11:27/11:29 2 4/10 6 18 5 11:30/11:32 2 4/10 6 19 6 2:32 2 4/10 6 20 PERCOLATION RATE: .33 (MM/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 3.5 FT. and 4.5 FT. COMMENTS: 0 NORTHERN GEOTECHNICAL ENGINEERING, INC./ TERRA FIRMA TESTING 111k1::::.• „.1,,,/ Laboratory Testing Geotechnical Engineering Instrumentation Construction Monitoring Services Thermal Analysis PROJECT CLIENT: Forge Engineering %GRAVEL 55.6 USCS GW PROJECT NAME: Denali %SAND 39.7 USACOE FC N/A PROJECT NO.: 4914-18 %SILT/CLAY 4.7 %PASS.0.02 mm N/A SAMPLE IAC.: TH-1 %MOIST.CONTENT 4.8 %PASS.0.002 mm N/A NUMBER/DEPTH: Lot 9 UNIFORMITY COEFFICIENT(Cu) 46.8 DESCRIPTION: Well-graded gravel w/sand COEFFICIENT OF GRADATION(Cu) 1.1 DATE RECEIVED: 7/11/2018 ASTM D1557(uncorrected) N/A TESTED BY: CH ASTM D4718(corrected) N/A REVIEWED BY: RJPC OPTIMUM MOIST.CONTENT.(corrected) N/A PARTICLE SIZE ANALYSIS ASTM D422/C136 LLS.SIEVE OPENING IN INCITES I US.SIEVE MASERS I NVDROME3flm SIEVE ANALYSIS RESULT 6 I.3 14 11731. �1 1/10 470 /10 /0 CV N200 too A l J SIEVE SIEVE TOTAL% SPECIFICATION 90 SIZE(mm) SIZE(U.S.) PASSING ("/a PASSING) 80 152.40 6” • 70 76.20 3" — ---- -- 38.10 1.5" 100 cg 60 __.`, 19.00 3/4" 76 50 —- - . 12.70 1/2" 62 9.50 3/8" 57 Dm 40 - —� ! — 4.75 #4 44 2.00 #10 32 30 0.85 #20 23 20 - - . - . 0.43 #40 15 --- • _ -- 0.25 #60 10 10 r _ — • 0.15 #100 7 0 . 0.075 #200 4.7 100 10 1 0.1 0.01 0.001 GRAIN SIZE(mm) HYDROMETER RESULT GRAVEL SAND ELAPSED DIAMETER TOTAL% COBBLES SILT or CLAY TIME(MIN) (mm) PASSING Colima Pine Coarse Medium Fine 0 0.5 l MOISTURE-DENSITY RELATIONSHIP ASTM D1557 2 4 145 _--— ._. ._.._._._ 8 --..._ — —— — 15 140 30 _ Y-- — 60 3 135 _— 250 _ , _ 1440 — z 130 A — HYDRAULIC COND. N/A 125 - (ASTM D2434) A - _ _ _ DEGRADATION — N/A 120 _ _---._._._- ...._.__.___._. _ (ATM'1'-313) PLASTICITY INDEX N/A 115 —- --r__. �. -- ASTM 4318 -. —. 0 2 4 6 8 10 12 14 16 MOISTURE CONTENT(%) The testing services reported herein have been performed to recognized industry standards,unless otherwise noted. No other warranty is made. Should engineering interpretation or opinion be required,NGE-TFT will provide upon written request. 11301 Olive Lane • Anchorage,Alaska 99515 • Phone:907-344-5934 • Fax:907-344-5993 • 3vww.nge-t/l.com MUNICIPALITY OF ANCHORAGE .'•( 9F4 qs% DEVELOPMENT SERVICES DEPARTMENT *�• �; 774. 4700 ELMORE ROAD ANCHORAGE, AK 99519—6650 vor,,,f,•� „� 9 SOILS LOG AND PERCOLATION TEST / . Michael E.Anderson . / # P• 4831-E .���/� LEGAL DESCRIPTION: DENALY ESTATES, BLOCK 2, LOT 9 l\ PROFESSION PERFORMED FOR: TROY DAVIS HOMES `\������� DATE: 7/9/2018 PROJECT No.: Professional Engineers Stamp: PARCEL ID#: 067-062-16 TECHNICIAN: N. SHAFER DI;PTII TEST HOLE 2 (feet) 1' OB SLOPE SITE PLAN 2 4 ••:'..'••.:'.,•:.. 5 SEE SITE PLAN t 7 : • SAND w/GRAVEL&SILT • 10 .,:,.;'''..!:':7.;':: . .:▪ • WAS GROUND WATER ENCOUNTERED? NO IF YES(rJ WHAT DEPTH, - '‘:4 DEPTH OF WATER AFTER MONITORING: NONE fi11 c',,`, ;1 DATE OFMONITORING- 7/28/18 12 : :;. DEPTH TO '-.1f.:.:...., `: DATE READING GROSS TIME NET TIME MATER NET DROP 1 3 ;;:,. ;;•^:;.:c: (MINUTES) (MINUTES) (INCHES) (INCHES) 14 " `'-::': 7/6 TEST HOLE PRESOAKED PRIOR TO TESTING: '',:::1 1 10:35/10:37 2 4/10 6 16 2 10:39/10:41 2 4/10 6 3 10:42/10:44 2 4/10 6 17 4 10:46/10:48 2 4/10 6 18 5 10:50/10:52 2 4/10 6 19 6 10:53/10:54 2 4/10 6 20 PERCOLATION RATE: .33 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 3 FT. and 4 FT. COMMENTS: See Laboratory Gradation. Material is 57.8% Sand. • • R NORTHERN GEOTECHNICAL ENGINEERING, INC,/ TERRA FIRMA TESTING Laboratory Testing Geotechnical Engineering Instrumentation Construction Monitoring Services Thermal Analysis PROJECT CLIENT: Forge Engineering %GRAVEL 39.4 USCS SP PROJECT NAME: Denali %SAND 57.8 USACOE FC N/A PROJECT NO.: 4914-18 %SILT/CLAY 2.8 %PASS.0.02 mm N/A SAMPLE LOC.: TI1-2 %MOIST.CONTENT 3.3 %PASS.0.002 mm N/A NUMBER/DEPTH: Lot 9 UNIFORMITY COEFFICIENT(CO 24.4 DESCRIPTION: Poorly-graded sand w/gravel COEFFICIENT OF GRADATION(Ce) 0.4 DATE RECEIVED: 7/11/2018 ASTM D1557(uncorrected) N/A TESTED BY: CH ASTM D4718(corrected) N/A REVIEWED BY: RJPC OPTIMUM MOIST.CONTENT.(corrected) N/A PARTICLE SIZE ANALYSIS ASTM D422/C 136 US.SIEVE OP6HMn IN MILS I us.SIEVE.u,JautS I HYIIIOMETER SIEVE ANALYSIS RESULT 100 6 ; w vz{a 1+ No rm r.I.. Ito repo sir SIEVE SIEVE TOTAL% SPECIFICATION 90 ,,. SIZE(mm) SIZE(U.S.) PASSING (%PASSING) • 80 ♦ - 152.40 6" 70 * .. 76.20 3" .... - - 38.10 1.5" 100 60 - ♦ 19.00 3/4" 87 50 - • _ . 12.70 1/2" 78 9.50 3/8" 72 m 40 ! 4.75 #4 61 - 2.00 #10 49 30 • 0.85 #20 37 20 . -- 0.43 #40 26 -. ' ♦ 0.25 #60 15 10 0.15 #100 7 �___......- .--•._-•_-AP___.-4_-_. 0.075 #200 2.8 0 - - 100 10 1 0.1 0.01 0.001 GRAIN SIZE(mm) HYDROMETER RESULT ELAPSED DIAMETER TOTAL% 1COBBLES GRAVEL SAND Ffx 1 SILT or CLAY I TIME(MIN) (mm) PASSING Coarse Fine Coarse Medium O 0.5 1 MOISTURE-DENSITY RELATIONSHIP ASTM D1557 2 4 145 ---...._. _. __. g 15 140 — , -- • - 30 _.—____ -- 60 135 _—_ 250 - 1440 cn z 13014 HYDRAULIC COND. 125 (ASTM D2434) N/A q DEGRADATION N/A 120 —.-- -. — (ATM 1-313) �_ --^.—_ PLASTICITY INDEX N/A 115 - ASTM 4318 0 2 4 6 8 10 12 14 16 MOISTURE CONTENT(%) The testing services reported herein have been performed to recognized industry standards,unless otherwise noted. No other warranty is made. Should engineering interpretation or opinion be required,NGE-TFT will provide upon written request. 11301 Olive Lane • Anchorage,Alaska 99515 • Phone:907-344-5934 • Fax:907-344-5993 • ii'ww.nge-tfi.co'n 99514 V11*0 MUNICIPALITY F ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 067-062-16 1. GENERAL INFORMATION Expiration Date: ` 9 —_ Complete legal description Denaly Estates, Block 2, Lot 9 Location (site address) 25286 Mc Intyre Road, Eagle River, AK Current property owner(s) Troy Davis Homes, Inc. Day phone 357-9394 Mailing address 1689 S. Knik Goose Bay Road #400, Wasilla, AK 99654 Real estate agent Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex AIJ!5* ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well 0 Private Septic R Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee Waiver Fee $ Date of Payment Receipt Number 6 5-3 5iD COSA # &500115X) Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering Phone 907-522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage AK 99503 Engineer's Printed Name Michael E. Anderson, P.E. Date 7/18/19 6. DSD SIGNATURE KSystem #1 Approved for 4 System #2 Approved for Disapproved Conditional approval for bedrooms bedrooms bedrooms, with the following stipulations: Original Certificate Date:0-9-19 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet Legal Description: Denaly Estates, Block 2, Lot 9 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 9/8/2018 Total depth 141 ft Cased to 141 ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) 24 in. Date of flow test for COSA 9/8/18 Static water level at beginning of test Artesian ft. Comments B. TANK DATA Age of tank(s) 10'5'16 years Tank type/material SEPTIC/STEEL Measured operating fluid level in septic tank NEW ❑ Standpipes/foundation cleanout per record drawing Date of pumping D. ABSORPTION FIELD DATA 5' Wide Trench Which system tested (date installed) 10/5/18 ❑ ALL standpipes present per record drawing Total measured depth from grade 4 ft (max) Measured depth to pipe invert from grade 3.5 ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: COSA Checklist yellow sheet Parcel ID: 067-062-16 Structure served by this system Well production at time of test 50+ gpm Water storage tank volume N/A gallons Well disinfected for coliform test? ❑ Yes ❑ N ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by Wheaton Water Wells Date of Sample 4/9/19 C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: Adequacy test date New Construction Results ❑ Pass For bedrooms Fluid depth prior to test in Water added gal New depth in Elapsed time min Final fluid depth in Absorption rate gpd Any rejuvenation treatment (past 12 months) If yes, enter date E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' M Yes Community Sewer Manhole/Cleanout > 100' ✓v7 Yes if No ft✓v Yes if No ft Neighboring Tank > 100' P- Yes if No ft Private Sewer/Septic Line > 25'dQ Yes if No ft Absorption Field on Lot > 100' R Yes if No ft Holding Tank > 100' dQ Yes if No ft Neighboring Absorption Fields > 100' Q Yes if No ft Water Main > 10' Animal Containment > 50' 0✓ Yes if No ft M Yes if No ft F71 Yes if No ft Water Service Line > 10` dQ Yes if No Manure/Animal Excreta Storage > 100' If septic tank is under driveway Community Sewer Main > 75' ✓� Yes if No ft Q Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' M Yes if No ft Surface Water > 100' Yes if No ft Property Line > 5'✓Q Yes Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' r71 Yes if No ft Private Wells > 100' Q Yes if No ft Water Main > 10' ✓l Yes if No ft Community Wells > 200' F71 Yes if No ft Water Service Line > 10` dQ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ®✓ Yes if No ft If absorption field is under driveway comment below Property Line > 10'✓Q Yes if No ft Wells on Adjacent Lots: Water Main > 10'✓Q Yes if No ft Private Wells > 100' Yes if No Water Service Line > 10' Yes if No ft Community Wells > 200' ❑✓ Yes if No Surface Water > 100' ✓❑ Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION�`�mt �L';aPiyfitirtrt� a•^�raw{ 1 certify that 1 have determined through field inspections and review '�:•°' ''°•., of Municipal records that the above systems are in conformance with V MOA COSA guidelines in effect on this date. 9th •} �iis art ia4 ametai�eiasai k#�i;Fi g� 3k is 41{.r� 9'II![kili0.ii(AP9}i2RkR64[tAi[RY#lliRi4l.Ysiai.. MICHAEL E. ANDERSON a ' N0. CE -4381 .•' " !J''•:, 7/20/19 COSA Checklist yellow sheet40 fRo'... ft ft ZO: C O s • sogQpD G" O • G �m As ZOOV Z O I Al m a 0 Y m2 O c o m o o m o O � �OOw. i C�� O m m a 6N m L Z o a m= o I L ag=Y am CQ� OL vEjt c r o ocv •awooi.o �w<vo�m o of Ell: Otto r3 _f -.Zpcm' OL C `+ WIN; as w m > o n al"'� a,ym Lo L _ ¢3ca°m a zam m a