HomeMy WebLinkAboutKNIK HEIGHTS BLK H LT 8 Onsite File
Knik Heights
Block H
Lot 8
#017 - 372 - 08
i nspection mepon= i - i - i t.aoc
Municipality of Anchorage
Community Development Department Page 1 of 2
On -Site Water and Wastewater Program
4700 Elmore St. - P.O. Box 196650 Anchorage, AK99519-6650 • http://www.muni.org/onsite • (907) 343-7904
ON-SITE
WASTEWATER INSPECTION REPORT
Permit Number: OSP181261
PID Number: 017-372-08✓❑ New ❑ Upgrade
Name:
Spinell Homes Inc
ABSORPTION FIELD
M Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound
Address
13130 Bainbridge Road
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
5
0.6 GPD/SF
10.0 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
3.0 Ft.
Gravel depth beneath pipe
TOFL
Subdivision
Block Lot
Knik Heights
H 8
Fill added above original grade
0.5+/- Fl.
Gravel length
2@50 Ft.
Township Range Section
Gravel width
2.5 Ft.
Beds: Number of Lines
I N/A
Distance between lines
N/A Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
1400 Ft2
2
14Ft.
Well
100+
100+
100+
TANK ❑+ Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
INFILTRATOR
Capacity
1500G,1.
Surface Water
100+
100+
Material
Number of compartments
Lot Line
5+I
10+
I
PLASTIC
2
NA
Foundation
10+
10+
I
LIFT STATION
Manufacturer
Capacity
Curtain Drain
50+.
50+
Gal.
Remarks
Pump on level at
J:Pump
off level
in.
High water alarm at
in.
Pump make an del
Electrical Inspections performed by
Installer
PIPE MATERIAL House to tank 3034 Tank to
drainfield 3034
POMRANING
Drainfield 3034 CO/MT 3034
Inspector Pannone Engineering Services
BENCH MARK (Assumed elevation) 92.01`1
Inspection ddates: �" 1013/18
god 10/4/18
Location and description
3°' 10/4/18
4"' 5/31/19
Bottom trim at house point A
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineer's Stamp
�� OF A�,4�k
Conditional Approval:
Date
P
TH
tteven ( annorie
CE 8149
Ilk �abAw
Approved— %_ _
`' Date 1
i nspection mepon= i - i - i t.aoc
DESIGN PARAMETERS
\ SEPTIC AREA (E) \ \ PRIMARY SEPTIC SYSTEM f
\ \ \ NO. BEDROOM: 5 (750 gpd)
\ \ \ \TANK SIZE: 1,5009
�<PERC RATE: 25.4 MPI
\ ` \ SOIL RATING: 0.6 GPD/SF
\ \ , AREA ROD: 1,250 SF
\ SYS. TYPE: DEEP TRENCH - 7.0'ED �
MIN LENGTH: 89.3 LF
A
10' UTILITY EASEMENT \ 1 USED:
U w \ \ ` (2EA) 50 A: 1,400 SF' E.D., 10.0' TD
\ \ TOTAL AREA: i,400 SF j
Ld T n ran m
\ 58
R�
RAIN FI \ � 74.0 y HOUSE (2EA] SOLE x 2.5'Yl x 7.0'ED x 10.0'TD DECK O INSTALLED CLEAN OUT AND IIAONITOR TUBE
AT EACH ENO ` I I I -7
\ \ \\V71 f
T1 F
ALL MEASURMENTS ± 1.0' (Ilhi H i
A B \ \ u } I LOT 8 111
%a
\ f
FC 3.0 31.0 \
INSTALLED 1500 SEPTI ' t
C TANK
T1 17.8 35.9 W FOUNDATION CLEAN OUT EFORE ' ' O MM j� M
T2 1 8.1 42.8 \ \ E DCO / FLOW SPIiTTER AFTER p/
c CD
DCO 23.3 45.0 o CO
C 1 27.3 45.2
M1 26.9 45.30 �� UTILITY EASEMENT
FS 28.9 47.40 �_ \
C2 52.0 25.60
I II
I Z
M2 52.3 26.10
C3 41.5 53.70
M3 42.3 54.50
C4 61.3 36.80
W V7!
M4 60.3 35.80 \ \ SEPTIC AREA
00 0
0 0
ZF U 3 3 V
O >
I.
i Z = w o ABOVE PIPE itry
J C_
LLp R.
V V VEd�-' OG: FG: 4.O It PIPS
EA5T:90.0 EAST:90.B FI tFABRIC
WEST:89.0 WEST: .5
_ iE5t M0:E +IFl SIFL 6iC
a+ rncv+u
z
0
1500g '
< SEPTIC TANK T' 0' DRAM ROCK ;
WEST: 86.0
PROFILE 9
SCALE:NTS EM
WEST: 86.0 Iz
n
T
+a
n
+n
OAiE
P. -m. 1-
NOTES:/ `®emsDcte
RECORD DRAWING PA ONE ENG WC, L ��
O� A����t 6/6/2019
P.O. BOX 100217 ANCHORAGE, AK 99510 '�� ""' '9S
PHONE (907) 272-8218 FAX (907) 272-8211 0rij�p �y�� Scale
le iT i p �� 1"=50'
... ... P.I.D. NO
DRAWN: ACP KNIK HEIGHTS, BLOCK H, LOT 8 ..... . , .. , . , 017-372-08
SPINELL HOMES INC r ?(even R. Ponnorie PERMIT NO.
13130 BAINBRIDGE ROAD �� j'•Eq 8149g•',,r�� OSP181261
PLAN ANCHORAGE, AK 99516 ����1F� pFESS Fe She.L 2
2 OF
( i\JISS!ƒ7727kf//2l22§;
°(_
2®
G222\
_
F -I
/
-
;
/{i(2
\
\
\
)
/{i(2
GI
\
\
\
)
www.sullivanwaterwells.com
Pump Installation Log
Well Drilling Permit Number: SW OSP181261 Date of Issue 9-5-18
Parcel Identification Number: 01737208000
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
JN`c1PAL r.0, MUNICIPALITY OF ANCHORAGE R,enr
' On-Site Water&Wastewater Program N0 SF,
PO Box 196650 4700 Elmore Road �.
• % Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997
http://www.muni.org/onsite
Dcpdrtiiivni
4 h,ONONPVi.
On-Site Water & Wastewater System Permit
Permit Number: OSP181261 Effective Date: 9/5/2018
Work Type: WellSeptic Initial Expiration Date: 9/5/2019
Tax Code Number: 01737208000
Site Legal Address: KNIK HEIGHTS BLK H LT 8 G:2836
Site Mailing Address: 13130 BAINBRIDGE RD, Anchorage
Owner: SPINELL HOMES INC Lot Size in Sq Ft: 43500
Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: 5
This permit is for the construction of:
El Disposal Field 0 Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: \ V16
r Itt Date: r
Issued By: , ,v' Date: ��
FOR
MUNICIPALITY OF ANCHORAGE
Community Development Department k Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On-Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 017-372-08
Property owner(s) Spinel) Homes, INC Day phone
Mailing address 1900 W. Northern Lights Blvd. #200 Anchorage, AK 99517
Site address NHN Bainbridge Road
Legal description (Sub'd., Block & Lot) Knik Heights, Block H, Lot 8
Legal description (Township, Range & Section)
Lot Size 43,500 Sq. Ft. Number of Bedrooms 5
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(IA all that apply)
Absorption Field H Initial El Single Family (SF) I XC
(w/wo ADU)
Septic Tank n Upgrade ❑
Duplex (D) n
Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑
Privy ❑ (SF and/or D)
Private Well C
Water Storage n
THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 1-7-g 7 Waiver Fees:
Date of Payment: I fiol/g Date of Payment:
Receipt Number: Oc1/29 Receipt Number:
Permit No. 65Pa c 1'a/ Waiver No.
Permit App_:- ::...c
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP181261, Deb Wockenfuss, 09/05/18
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP181261, Deb Wockenfuss, 09/05/18
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP181261, Deb Wockenfuss, 09/05/18
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP181261, Deb Wockenfuss, 09/05/18
E P[a9/VS
MUNICIPALITY OF F ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Parcel I.D. 017-372-08
1.
Certificate of On -Site Systems Approval
GENERAL INFORMATION
Complete legal description Knik Heights BH L8
Location (site address) 13130 Bainbridge Road
Expiration Date: —t
Current property owner(s) Spinell Homes Day phone
Mailing address
Real estate agent
1900 W Northern Lights Blvd #200 Anchorage, AK 99517
2. TYPE OF DWELLING:
El Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex).
3. NUMBER OF BEDROOMS: 5
Day phone
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
El
Private Septic
n
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for:
Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $5� Waiver Fee $
Date of Payment 731%9 Date of Payment
Receipt Number,�pp,,�,, 63722? Receipt Number
COSA # U1115 C1 ai'lia Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures
outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or
wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated
herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and
inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State
codes, ordinances, and regulations in effect at the time of installation.
In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MoA
COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time
of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on
the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not
guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot
provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole
benefit of the owner listed above. Reliance on this report by another person is at their own risk. Pannone Engineering Services LLC highly
recommends buyers hire their own engineer to evaluate this report.
Name of Firm Pannone Engineering Services
Address P.O. Box 1807 Palmer, AK 99645
Engineer's Printed Name Steven R. Pannone P.E.
DSD SIGNATURE
System #1 Approved for bedrooms
System #2 Approved for bedrooms
Disapproved
Phone (907) 745-8200
Date / Q'6196f
Conditional approval for bedrooms, with the following stipulations:
.. , f!/i,._
By: ��.�--Y Original Certificate Date: C( _10 —�
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
COSA Checklist
Legal Description: Knik Heights BH L8 Parcel ID: 017-372-08
If more than 1 septic system on lot: COSA Checklist # of Structure served by this system _
A. WELL DATA
K Well log is filed with Onsite (or attached)
Date drilled 9r2,i18
Total depth 400 ft
Cased to 124 ft
®❑ Sanitary seal is functioning correctly
❑® Wires are properly protected
Casing height (above ground) 24 in.
Date of flow test for COSA n/a
Static water level at beginning of test n/a ft.
Comments
Well production at time of test n/a gpm
Water storage tank volume n/a gallons
'Nell'Jfsin ec ems- oliform test? ❑ Yes ❑✓ No
(j Coliform b c� to ' Is gative
Nitrate Z`��mg/L ❑ Nitrate less than MRL (ND)
Arsenic iN ug/L ❑ Arsenic less than MRL (ND)
'Coll-e-ctedW/Pannone Engineering Services
Date of Sample
B. TANK DATA C. LIFT STATION
Age of tank,0r3n3 ears
9 (s) Y [:1 Required maintenance completed
Tank type/material $epic''. Age of lift station years
Measured operating fluid level in septic tank n/a Lift station material
❑® Standpipes/foundation cleanout per record drawing Comments:
Date of pumping
D. ABSORPTION FIELD DATA Deep Trench
Which system tested (date installed) ,or<,zo,s
Adequa y test date n/a
H ALL standpipes present per record drawing
Results ❑✓ Pass For 5 bedrooms
O
Total measured depth from grade e ft max)
Fluid depth prior to test in
Measured depth to pipe invert from grade 3.5 ft (min)
Water added gal
❑ N/A — pressurized field
New depth in
Monitor tubes go to bottom of effective. If not, state
depth into effective
Elapsed time min
Q Code -required soil cover over field
Final fluid depth in
❑ System presoaked
Absorption rate gpd
(Required if vacant for greater than 30 days prior to
Any rejuvenation treatment (past 12 months)
date of test)
Gallons introduced gallons
If yes, enter date
Comments/Deficiencies:
COSA Checklist yellow sheet
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
El Yes
if No
Community Sewer Manhole/Cleanout > 100'
❑✓ Yes
if No
ft
M Yes
if No ft
Neighboring Tank > 100' [, Yes
if No
ft
Private Sewer/Septic Line > 25' M Yes
if No ft
Absorption Field on Lot > 100' M✓ Yes
if No
ft
Holding Tank > 100' M Yes
if No ft
Neighboring Absorption Fields > 100'
if No
ft
Animal Containment > 50' Z✓ Yes
if No ft
0 Yes
if No
ft
ft
If septic tank is under driveway comment below
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' ❑✓ Yes
if No
ft
E✓ Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
El Yes
if No
ft
Surface Water > 100'
El Yes if No ft
Property Line > 5'
El Yes
if No
ft
Wells on Adjacent Lots:
Wells on Adjacent Lots:
Absorption Field > 5'
El Yes
if No
ft
Private Wells > 100'
❑✓ Yes if No ft
Water Main > 10'
R✓ Yes
if No
ft
Community Wells > 200'
✓� Yes if No ft
Water Service Line > 10'
(]✓ Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
0
Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
F71
Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'
Q
Yes
if No
ft
Private Wells > 100' Yes if No ft
Water Service Line > 10'
n
Yes
if No
ft
Community Wells > 200' Yes if No ft
Surface Water > 100'
0
Yes
if No
ft
F. ENGINEER'S COMMENTS
G. ENGINEER'S CERTIFICATION
l certify that / have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
COSA Checklist yellow sheet
_._._O
�>y/�
W
/
4 m m
min U,yl m
C
O Z
O \ Z
m \
N a m �ipC 0 O r
V p�
Nmi'DOOm-' Z�S
m Smp Omm=-t{
2 mm z N--�m�o1 (On
O m m N i A 3 N
t y u
h
go ADtnNni�
n c Axo-
m x m m
N n O T N o O m n y`-
-�
..r m mzC.c� �m me
Y C7 m=gr �C'f mm�O _=
n Nog ZZ�CCYOJJ VVZIIO�OS
m
w
O
BAINBRIDGE ROAD
r—
INz
r=
Om
41.00 00
ui0
�0
C "
n N
A
Q
= C
V)
O
N 00'02'00"1Y 145.00•
10' UnUTY ESui.
-r -
I
1
I
- - - - - - - - - - -
- - -I-
1
1
I
I
of
�I
I
1
1_
IC
�I
I�
m
I
I
_ I
m 1
•� y
sx I m
al
C5
in
t.u0 l_ o
I m
O
nC,
m�l
pO
�I
r0y
6z
26...
I
26.0'
I
$
I
�
I
O
FO
1 �
F�
I
I
I
I
N 02'00'W 145.00'
O
BAINBRIDGE ROAD
r—
INz
r=
Om
41.00 00
ui0
�0
C "
n N
A
Q
= C
V)
O