Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T14N R2W SEC 11 LT 51
Onsite File � sD Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP191093 PID Number: 050-252-20 Dwelling: ❑ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑ Upgrade Name Michael Brusehaber ABSORPTION FIELD ❑ Deep Trench ON Wide Trench ❑ Bed ❑ Mound Site Address 16219 Poppy Ln. Eagle River, AK ❑ Other Phone Number of Bedrooms Soil Rating depth from original grade 268-1088 4 1.0 GPD/SF JTotal 9.7 / 9.6 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 9.2/9.1 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot 51 Fill added above original grade 0.4 Ft. Gravel length 2 @ 63 Ft. Township Range Section 14N 2W 11 Gravel width 5.0 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding . Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 630 Ft2 2 >6 Ft. Well >100' >1 QQ' N/A N/A >25' TANK 9 Septic ❑ S.T.E.P. ❑ Holding [:]Other Manufacturer Capacity Anchorage Tank 1,250 Gal. Surface Water >100' >1 QQ' N/A N/A Material Number of compartments Lot Line >5' >10' N/A N/A NA Steel 2 Foundation 1 6'* >1 0' N/A N/A LIFT STATION Manufacturer Capacity Gal. Remarks Tank is outside 1:1 foundation soil bearing prism. Alarm location Electrical installed by PIPE MATERIAL House to tank D3034 Tank to drainfield D3034 Installer Martin Construction Company Drainfield D3034 CO/MTD3034 Inspector J. Mlllette BENCH MARK (Assumed elevation) 100 ft Inspection151 7/10/19 7/11/19 Location and description Bottom of Siding. 3`d 7/12/19 4th ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp ®� Conditional Approval: Date +�P,°•°°°° °'•°�S .• d,�® �o ....:.49th .."s.... ®............ I..................wo......`. MICHAEL E. ANDERSON " Septic System®�!� Approved Date 7 l 026;10 % No. CE -4381 :'°_ 10 IV +'c` ° 6/25/20 ,.••°'����4' �� Note: this approval does not include well permit requirements. (Rev 05/02/18) LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 2 SLOPE SLOPE SITE PLAN See Site Plan DATE READING GROSS TIME(minutes)NET TIME(minutes) DEPTH toWATER NET DROP PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) T14N R2W SECTION 11 LOT 51 J. Williams Development Services Department 4700 Elmore Road Anchorage, AK 99519-6650 Municipality of Anchorage DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH OF WATER AFTER MONITORING: IF YES @ WHAT DEPTH? NO - NONE <1 6 5 6 050-252-20 Michael Brusehaber Professional Engineers Stamp: 1' OG/OL POORLY GRADED GRAVEL 5-12-20 BOH GP POORLY GRADED GRAVEL LENSE ABSORBS WATER FASTER THAN 1 MINUTE PER INCH. WATER LEVEL MEASUREMENTS COULD NOT BE MADE DUE TO HIGH POROSITY. 5-13-20 5-19-20 NOTE: TEST HOLE DEEPENED AFTER INSTALLATION OF ABSORPTION TRENCHES. MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PQ Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP191093 Work Type: Septic Initial Tax Code Number: 05025220000 Site Legal Address: T14N R2W SEC 11 LT 51 G:0051 Site Mailing Address: 16219 POPPY LN, Eagle River Owner: BRUSEHABER MICHAEL Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date. Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 4/18/2019 4/1712020 �:•�� © Disposal Field Q Septic Tank ❑ Holding Tank, ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: The entire proposed primary drainfield is not within the 30 ft radius of a percolation test. In addition, the east drainfield is not within 30 ft of a test hole that demonstrates separation to groundwater and impermeables. An additional test hole is required prior to construction to confirm minimum vertical separations are being met and to confirm the percolation rate along the entire length of the drainfields. If the results require a design change, construction shall stop pending Onsite review and approval of a change order. Please submit results with the inspection report. Received By: Y Issued By: Date: Date: / 0 _ter 4 EROW&IS MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program Parcel I.D. ON-SITE SEWER/WELL PERMIT APPLICATION 050-252-20 Property owner(s) Michael Brusehaber Mailing address 900 W 23rd St, Anchorage, AK 99503 Site address 16219 Poppy Lane Anchorage, AK Legal description (Sub'd., Block & Lot) T14N R2W SEC11 Lot 51 Legal description (Township, Range & Section) Lot Size 108,900 Sq. Ft. Number of Bedrooms 4 Day phone 268-1088 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field [54 Initial 0 Single Family (SF) IN (w/wo ADU) Septic Tank ❑X Upgrade ❑ Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Sol Waiver Fees: Date of Payment: u �I�((9 Date of Payment: Receipt Number:C�325r!� Receipt Number: Permit No. Q,5(2 Ict INS Waiver No. Permit App_„- : • :'—C PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) April 10, 2019 MOA Development Services Dept, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: T14N R2W SEC11 L51 – 16219 Poppy Lane Septic System Design and Permit Application Dear On-Site Services Engineer: The owner on the subject lot intends to construct a four-bedroom home on the property. We are submitting this design and permit application for the construction of a new septic system. The attached site plan identifies the location of the home and the existing well along with the proposed septic locations. No conflicts exist between the proposed system and any other well or septic system on this or adjacent lots. The ground surface on the lot slopes gently southwesterly. There are no slopes greater than 25% within 50 feet downslope of the proposed site. Drainage arrows are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. Please refer to the attached test hole logs and plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Michael E. Anderson, PE 4/10/19 4-10-19 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191093, Rebecca Carroll, 04/18/19 FCO 10050 0 FEET 1"=50' 1,250-GALLON SEPTIC TANK NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND CO MT T14N R2W SEC11 LOT 51 50' BLM R.O.W. & UTILITY RESERVE POPPY LANE EXISTING WELL PROPOSED WELL 2-60' LONG x 5' WIDE x .5' EFFECTIVE DEPTH ABSORPTION TRENCHES. APPROX SEPTIC SYSTEM - QUANICS CAT II TH1 TH2 FOUR BEDROOM HOME ALTERNATE SITE: CATEGORY III SYSTEM w/20' LONG x 5' WIDE x .5' EFFECTIVE DEPTH ABSORPTION TRENCH. APP. RATE 6.0 GPD/SF. CO CO CO 2CO SV SV MT FS 15% >25% 4-16-19 >25% >25% Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191093, Rebecca Carroll, 04/18/19 T14N R2W SECTION 11 LOT 51 DESIGN FACTORS: SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: <1 MIN/IN APPLICATION RATE: 1.0 GPD/SF 5' WIDE TRENCH SYSTEM 1,250-GAL SEPTIC TANK TYPICAL TRENCH SECTION (NO SCALE) 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 5' 6" 3' NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY BOTTOM OF TRENCH: 4.0' BELOW GRADE FLOW LINE ELEVATION: 3.5' BELOW GRADE TOP OF TRENCH: 0.5' ABOVE GRADE 600 GPD / 1.0 GPD/SF /5' WIDE * 1.0 RED. FACTOR = 120 LF TRENCH REQUIRED (120 LF SPECIFIED) ..\..\Admin\Schiller seal\Signed seal.jpg 2' 6" 6" MOA APPROVED SAND 4-10-19 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191093, Rebecca Carroll, 04/18/19 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 1 SLOPE SLOPE SITE PLAN See Site Plan DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) T14N R2W SECTION 11 LOT 51 3-14-19 J. Williams Development Services Department 4700 Elmore Road Anchorage, AK 99519-6650 Municipality of Anchorage DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH OF WATER AFTER MONITORING: IF YES @ WHAT DEPTH? NO - NONE <1 6 4 5 050-252-20 Michael Brusehaber Professional Engineers Stamp: ..\..\Admin\Schiller seal\Signed seal.jpg 1' OG/OL POORLY GRADED GRAVEL 3-21-19 BOH GP POORLY GRADED GRAVEL LENSE ABSORBS WATER FASTER THAN 1 MINUTE PER INCH. WATER LEVEL MEASUREMENTS COULD NOT BE MADE DUE TO HIGH POROSITY. 4-10-19 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191093, Rebecca Carroll, 04/18/19 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 2 SLOPE SLOPE SITE PLAN See Site Plan DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) T14N R2W SECTION 11 LOT 51 3-14-19 J. Williams Development Services Department 4700 Elmore Road Anchorage, AK 99519-6650 Municipality of Anchorage DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH OF WATER AFTER MONITORING: IF YES @ WHAT DEPTH? NO - NONE <1 6 5 6 050-252-20 Michael Brusehaber Professional Engineers Stamp: ..\..\Admin\Schiller seal\Signed seal.jpg 1' OG/OL POORLY GRADED GRAVEL 3-21-19 BOH GP POORLY GRADED GRAVEL LENSE ABSORBS WATER FASTER THAN 1 MINUTE PER INCH. WATER LEVEL MEASUREMENTS COULD NOT BE MADE DUE TO HIGH POROSITY. 4-10-19 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191093, Rebecca Carroll, 04/18/19 OWNER OF LAND: ADDRESS: LEGAL DESCRIPTION DATE: 1-28-19 PERMIT NUMBER: OSP181367 DATE OF ISSUE: 10-17- 18 TAX IDENTIFICATION NUMBER 05025220000 Is well located at approved permit location: ®Yes ❑No Method of Drilling: ®air rotary ❑cable tool Depth of Well: 144' Casing Type: Steel Wall thickness .250 inches Diameter: 6 inches, depth 144 feet Liner type Static Water Level: 54 feet Recovery Rate 3.75 ® gpm ❑ gph Method of Testing Air Well Intake Opening Type: ® open end open hole ❑ Screened Start feet Stopped ® Perforations Start 70 feet Stopped 82 Grout Type: Bentonite Volume: 50lbs Depth: from 2 feet, to 42 feet Well Disinfected Upon Completion: ®yes ❑ no Method of Disinfection: Chlorine 50 PPM lip - DOC CO dba BILL 8. COLE ULLIVAN WATER WELLS P.O. Box 670269, Chugiak, AK 99567 688-2759 Michael Brusehaber T14N R2W SEC 11 LOT 51 Comments: Bore Hole Data Depth From To 0 2 2 4 4 14 14 38 38 59 59 65 65 69 69 75 75 82 82 136 136 142 142 144 Casing Stickup Overburden Silty Sand & Gravel Silty Sand & Gravel w/ Boulders Silty Sand & Gravel Silt w/ Some Gravel. Water Clay & Gravel Silty Sand & Gravel. Water Tight Sand & Gravel Wet Clay & Gravel Shale Soft Bedrock Drillers Name: Cole Sullivan ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. Matsu Borough: Department of Environmental Conservation. Pump Installation Log Arctic Pump & Well Inc . Jim Sullivan PO Box 770197 Eagle River, AK 99577 (907) 688 -2510 (907) 243 -2282 jim@arcticpump.com osp181367 050-252-20-000 10/17/2018 t 14n r2w s11 L51 51 Royce Martin PO BX 773326 Eagle River AK 99577 7/10/2019 133 Franklin 10FRD05P4-2W230 153 psi 13 Feet B-10 Well Drilling Permit Number: Parcel Identification Number: Date Of Issue: Legal Description Lot: Block: Property Owner Name Address: Pump Installaion Date: Pump Intake Depth Below Top of Well Casing: Pump Manufacturer's Name Pump Model: Pump Size: Pitless Adapter Burial Depth: Pitless Adapter Manufacturer's Name Pitless Adapter Installer: Well Disinfected Upon Completion? Method of Disinfection: u/k Yes Chlorine Comments: Pump Installer Name: Arctic Pump & Well, Inc. 5Y Friday, May 15, 2020 'Fl --:fi-=_/a ilmf,lfitnrs \>#H+< ARcrrc Punap & Wel-l lruc. Jim Sullivan, CPI PO Box 774197 Eagle River, AK99577 (907) 688-25 1o (907) 243-2282 i im@arcticButtlp. cgnl Well Decommissioning Log Legal Address: Subdivision: T:14n R2w Block: Lot: Section 11 Lot: 51 On-site Water & Wastewater Program certihed contractor performing the well decommissioning: Name: Jim Sullivan Signature: Company: Arctic Pump & Well, Inc Well Decommissioning Date 7-9-19 Method of Decommissioning: AMC 15.55.060L1 a.E b.E c.[] Location: Use the space below to provide a drawing of the property showing the following items: e North Arrow o Decommissioned well o Other water wells on the property o Two separate swing tie distances for each well shown on the drawing Note: the swing tie distances shall be measured from either permanent structures or the property corners. -53',&-\ 0ccO gv1 Pl e tf loere (,t-t t 1 ni,J \l 0 f p) Arctic Pump & Well, Page I of I Inc. N,(IFAl1rr MUNICIPALITY OF ANCHORAGE �� , .........,....OF , \\i 11 1 On-Site Water&Wastewater Program �, a ,5 PO Box 196650 4700 Elmore Road Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 httpa/www.muni.org/onsite r D part111 1 9F'<1,URAc'� On-Site Water System Permit Permit Number: OSP181367 Effective Date: 10/17/2018 Work Type: Well Upgrade Expiration Date: 10/17/2019 Tax Code Number: 05025220000 Site Legal Address: T14N R2W SEC 11 LT 51 G:0051 Site Mailing Address: 16219 POPPY LN, Eagle River Owner: BRUSEHABER MICHAEL Lot Size in Sq Ft: 108900 Design Engineer: FORGE ENGINEERING Total Bedrooms: 4 This permit is for the construction of: ❑ Disposal Field 0 Septic Tank 0 Holding Tank 0 Privy Er Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: 1. When well testing is complete, the well driller shall place an approved sanitary seal on the well head and no pitless adapter or pump shall be installed until an approved wastewater disposal system has been constructed. 2. The existing well is to be decommissioned unless a need for it is demonstrated and accepted by Onsite. Received By: (i/A 714641) /71 l ,0 i Date: v I (� Issued By: 4 s/ G(1„,„A ,y., Date: (0 PNS MUNICIPALITY OF ANCHORAGE 01111• " Community Development Department \ *; + Phone: 907-343-7904 Development Services Division -' Fax: 907-343-7997 On-Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 050-252-20 Property owner(s) Michael Brusehaber Day phone 268-1088 Mailing address 900 W 23rd St, Anchorage, AK 99503 Site address 16219 Poppy Ln Legal description (Sub'd., Block & Lot) T14N R2W SEC11 Lot 51 Legal description (Township, Range & Section) Lot Size 108,900 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field E Initial ❑ Single Family (SF) (w/wo ADU) Septic Tank ❑ Upgrade X Duplex (D) ❑ Holding Tank ❑ Renewal n Multiple Dwellings ❑ Privy I I (SF and/or D) Private Well n Water Storage n THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. J (Signature of property owner or authorized agent) Permit/Rush Fees: 215 Waiver Fees: Date of Payment: 16 tIZIIS Date of Payment: Receipt Number: °VT?.t. Receipt Number: Permit No. OS P 13C0-i- Waiver No. Permit App_.-:•:.....c Munidpality of Anchorage On-s,te Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181367.Cob VVrxkenfuss. IC/-7/ PO BOX 240773 ANCHORAGE, AK 99524 GE 577.7773 677-7766 (FAX) ENGIN E E R I N G FORGECIVIL.COM October 11, 2018 = OF MOA Development Services, On-Site Water& Wastewater Program ;I*.. 49 TM lV . *l� 4700 Elmore Rd •'"" '• ' ••• Anchorage, AK 99507 •; __.- ••• •• ti /f Benja • hiller . j ()9e'•• •CE 12592 . `�/ Subject: T14N R2W SEC 11 Lot 51 — 16219 Poppy Ln T Ti, .)0/11/18.. ��,� Well permit lk>t��v ESS� Dear On-Site Services Engineer: The owner of the above lot would like to dig a new well. There is an existing well on the lot, although there is no record indicating when it was drilled. Recently, SullivanWaterWells verified the depth, installed a temporarypump, and tested the well flow. The flow was near 2 gal/min, and the homeowner was not satisfied with the flow rate or their assessment of the water quality. They would like to drill a new well closer to the eastern portion of the lot. Although typicallya lot needs to have a septic system in orderto get a well permit,there are times where a permit can be approved before the system is installed. In this case,there is already a well on the lot.The owners are not planning on selling the lot if they don't find better water;this lot is next to their family, and they definitelyplan on building on it. Their reasoning is that they want to know definitely where their well will be before they dig test holes for the septic system, in case they end up needing to move the proposed septic location. In short,there is no additional risk to digging a new well on this lot before the septic system is permitted. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater T 14 N R 2 W S E C 11 LOT 51 REVIEWED FOR CODE COMPLIANCE OSP181367,Loeb I4t)ckenfuss, 10117/1 LOT 41 BLM LOT 51 . PROPOSED SEPTIC LOCATION —\\ - - - 100' FROM i 100' FROM PROPERTY LINE: ADJACENT WELL 1 PROPERTY LINE: INFORMATION NOT i ADJACENT WELL INFORMATION NOT AVAILABLE AVAILABLE 4 LOT 50C W ^t ROPOSED HO e APPROX SEPTIC F__ 3 SYSTEM-Q UANICS — le CAT II 4 a P , , , � ! :. LOT 50D EXISTING WELL \ I PROPOSED WELL N NI 50'BLM R.O.W. UTIZ'ITY.gESERU,E ` _ — `- \ I N ,- POPPY LANE e I 4Y woo LOT 52 Id ' GE I ENGINEERING I -e-73 OF 1 OF meq' A.*.y:' 1-.1.4°0 g*:49TH �� •*r% j r Bja enni6 chiller : j �' % .'DEQ V%Ffl CE622592 ��/ 0 50 100 ll1iF,2...... :,.\'(t'r = = = FEET �N\\N��1"` 1"=50'