Loading...
HomeMy WebLinkAboutKNIK VIEW ESTATES LT C-1Onsite File #051-043-62 Municipality of Anchorage On -Site Water and Wastewater Program ° (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181383 PID Number: 051-043-02 Dwelling: 0 Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New ❑ Upgrade Name: Troy Davis Homes ABSORPTION FIELD ❑ Deep Trench ❑Shallow Trench MR Bed E] Mound Address 1689 Knik Goose Bay Rd 400 Wasilla, AK 99654 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 310-2501 Three (3) 0.7 GPD/SF 2.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 1.5 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot Knik View Estates, Tract C Fill added above original grade 2.0 Ft. Gravel length 45 Ft. Township Range Section Gravel width 15 Ft. Beds: Number of Lines 3 Distance between lines 5.0 Ft. SEPARATION DISTANCES Tol Septic Absorption ' Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank j Field Tank Line675 Ft2 Ft. Well>100' >100' >100 ��A >25' TANK ❑ Septic 0 S.T.E.P. ❑ Holding El Other g Manufacturer Anchorage Tank Capacity 1,250 Gal. > Surface Water > 100' >100' >100' N/A Material Number of compartments Lot Line >5' 3' >10' N/A Steel 2 NA Foundation j 9.3' >10' >10' N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted i Orenco /Anchorage Tank 250 Gal. Remarks Waver to property line OSV181088. Pump on level at 25 in. Pump off level at 13 in. High water alarm at 27 in. Septic tank is secured with concrete ballast to prevent flotation. Tank is 9.3' fromfoundation, Pump make and model Electrical Inspections performed by but outside foundation soil bearing prism. PF2005 Powertec Electric PIPE MATERIAL House to tank F810 Tank to drainfield D1785 Installer Ursa Minor Excavation & Landscaping Drainfield D1785 CO/MT Inspector J. Williams / J. Millette BENCHMARK (Assumed elevation) 100 ft Inspection 151 3/6/19 3/8/19 Location and description 2nd 3 r 4'h Bottom of siding @ point A. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp g OI: Conditional Approval: Date PP ., X. .........1-7 - ---- ------ 49 th °3 --- - -- ---- - . .... . .. ... .... .... . :: .. ....... ............................................... PdICHAEL E. ANDERSON ; QJ ffi Approved lul_Date 5/2 / `j No. CE -4381 °: ' °•° 4(22/19 ,.••'`°c���� °••.......... _ (f'A— --- -- ---- e��ROFESs\ mspecaon r-,epor[_a-i-rz.aoc KN I K VI EW ESTATES TR -C L -C 1 PERMIT # OSP181383 PID # 051-043-02 PLAN AS -BUILT 0 50 100 GEFEET ENGINEERING 1"-50' A B C FCO 3.4 47.2 SV1 45.4 13.3 SV2 47.7 19.7 MH 48.2 21.1 MT1 41.7 25.7 MT2 47.5 39.4 MT3 10.9 47.8 MT4 23.0 56.2 LEGEND CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT MH - MAN HOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE CONTOUR INTERVAL -5' KN I K VI EW ESTATES TR -C L -C 1 PERMIT # OSP181383 PID # 051-043-02 vu.T 101.1 FINISH GRADE 2 n 99.1 ORIGINAL GRADE n 2" INSULATION MOA APPROVED FILTER SAND 97.6 97.6 97.1 95.1 97.1 45' - 87.1 GROUNDWATER @ 93.1 10/11/18 �•'c OF jk *.- G 91� PROFILE AS -BUILT (NO SCALE) `Jc... Pte• 49th MICHAEL E. ANDERSON NO. CE -4381 61 1,4 PROFESSION 0 HOUSE DETAIL Scale: 1" = 30' REBECCA PORCH tip3 �9 CIRCLE .0 NO 1 STORY RESIDENCE roti ' 8. x14.2' NOTE: LOT IS SERVED BY A DECK DEC COMMUNITY WATER SYSTEM. / � � /CURVES / / / Curve 1 RaElw Length 1 200.00 174.43 /1 5 / / _V\V 3 1 210.00 1 195.3 10' T&E EASEMENT O (Plat 86-113) / 1 1.87' / 30.07• / _ j \sz� Lot C-2 TEMPORARY PUBLIC ACCESS EASEMot ENT / IZ S S'sJA9' Lot C-1 — '�• — 29.3' 58,460 s.f. a.11' c�S S Z / See 30' PUBLIC ACCESS EASEMENT (Plat 86-113) ��' \\\ m / / 100' POWER EASEMENT NOTE /(SEE 15' DRAINAGE EASEMENT (Plat 86-113) — — — S 89.4940 424.18 PLOT PLAN AS BUILT —2L SCALE —11 = 40' GRID NW 1553 Project No. 18-491/B7 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates, in C . (907) 522-6476 Phone QooO�pOO (907) 522-4625 Fax o p F q X04 Professional Land Surveyors kenolongsurvey.com y jonothanDiangsurvey.com OdP '''........ -75400 I hereby certify that I have surveyed the following described property: �' 0 Lot C-1, KNIK VIEW ESTATES (PLAT No. 2019-37) o :` 49?H �0 Anchorage Recording District, Alaska, and that the Improvements situated thereon are 0"""" ..... j............... t7 within the property lines and do not encroach onto the property adjacent thereto, thatPA ch! ..1 .D no Improvements on the property lying adjacent thereto encroach on the surveyed �'p' KENNIIEpT G . . LAN ... premises and that there are no roadways, transmission lines or other visible Qac S`y��q�a easements on said property except as Indicated hereon. Q ' •th4GalOt '-..LS-5202.•'' cApOO Dated this the Day of MG at Anchorage, Alaska 4 ,o "••... �Ooo 40oROFfSSIONAL �o It Is the responsibility of the owner to determine the existence of any easements, �Opppoo� covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963 HOUSE DETAIL Senle• 1" = .,in' L=98.33' R=20.00' j N 09'46'34"E 7.35' NOTE: LOT IS SERVED BY A COMMUNITY WATER SYSTEM. — PLOT PLAN AS BUILT X SCALE 1" —=6(y GRID NW 1553 Project No. 18-491/86 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates, inc. (907) 522-6476 Phone 00000p4� (907) 522-4625 Fax o OF A Professional Land Surveyors kenOlongsurvey.com Y jonathanOlangsurvey.com DO X 1 hereby certify that I have surveyed the following described property: PROPOSED TRACT C. KNIK VIEW ESTATES (PLAT No. 86-113) o * 49TH �* 0� Anchorage Recording District, Alaska, and that the Improvements situated thereon are �" """"' •" within the property lines and do not encroach onto the property adjacent thereto, that no Improvements on the property lying adjacent thereto encroach on the surveyed �" 1• KENNX1%premises and that there are no roadways, transmission lines or other visibleeasements on said property except as Indicated hereon.Dated this the 2$Da �wauLd 2u �02.• Day of 1�� at Anchorage, Alaska ...... 44%n�0�5J 0 It Is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963 �,N,�F�CiTY Op MUNICIPALITY OF ANCHORAGE ,�,;, On-Site Water&Wastewater Program \, ' 'S PO Box 196650 4700 Elmore Road Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 http://www.muni.org/onsite I)t•I,arttnt•nt 9NCHORRG� On-Site Wastewater Disposal System Permit Permit Number: OSP181383 Effective Date: 10/26/2018 Work Type: Septic Initial Expiration Date: 10/26/2019 Tax Code Number: 05104302000 Site Legal Address: KNIK VIEW ESTATES TR C G:1558 Site Mailing Address: 22351 JUDD DR, Chugiak Owner: TROY DAVIS HOMES Lot Size in Sq Ft: 106939 Design Engineer: FORGE ENGINEERING Total Bedrooms: 3 This permit is for the construction of: II Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing • Received By: V,,(/I, 2 y ��, � Date: 0 Issued By: Patet C9yQS' Date: 0 0� • Old Municipality of Anchorage �)a�o,u•uncn, P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 http://www.muni.orq/Onsite Development.Services Department On-Site Water and Wastewater Section **** VARIANCE/WAIVER REVIEW *** Waiver#: OSV181088 COSA#: Permit#: OSP181383 PID#: 051-043-02 Legal Description: Knik View Estates Tract C Engineer: Forge Engineering Applicant: Troy Davis Homes Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 3.0 feet. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: Date: 05/2°1 0 Approved by: l 6-,z/U0 Name of Reviewer **** VARIANCE/WAIVER REVIEW **** MUNICIPALITY OFANCH • E C a ^� . I ♦ i l' O Community Development Department 4 Pjq e: s! -343-7904 Development Services Division s a OC I G L ax: e -343-7997 On-Site Water&Wastewater Program h� ON-SITE SEWER/WELL PERMIT APPL A I Parcel I.D. 051-043-02 Property owner(s) Troy Davis Homes Day phone 310-2501 Mailing address 1689 Knik Goose Bay Rd #400, Wasilla, AK 99654 Site address 22351 Judd Drive Chugiak, AK 99567 Legal description (Sub'd., Block & Lot) Knik View Estates, Tract C Legal description (Township, Range & Section) Lot Size 106,939 Sq. Ft. Number of Bedrooms Three (3) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field n Initial n Single Family (SF) U (w/wo ADU) Septic Tank X Upgrade I I Duplex (D) I I Holding Tank I I Renewal Multiple Dwellings I I Privy (SF and/or D) Private Well Water Storage I I THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Lot Line Waiver Distance: 3' I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 5(09 Waiver Fees: 01 5 Date of Payment: lojaall� Date of Payment: 1 C/� / 1 S Receipt Number: a5---4-60/f) Receipt Number: 0 Si Permit No. eLSPIY12.3 Waiver No. 0 u V 11 O Permit App_'•. ,...,c GE tENGINEERING PO BOX 240773 ANCHORAGE,AK 99524 522-7773 677-7766(FAX) October 25, 2018 MOA Development Services Dept, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Knik View Estates,Tract C—22351 Judd Drive Septic System Design and Permit Application Dear On-Site Services Engineer: The developer of the subject lot intends to construct a 3-bedroom home on the property. We are submitting this design and permit application for the construction of a new septic system. The attached site plan identifies the location of the home and the proposed septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. Adjacent lots are served by a community water system. This lot will also be served by the community water system. The ground surface on the lot slopes moderately to the northwest. Ground contours are shown on the site plan showing the grade and direction of flow. Storm water drainage will not impact this septic system. The new beds will be constructed parallel to the slope as much as possible. The new septic system will be a minimum of 100' from all wells and surface water. The alternate site is located more than 10' from the primary site. The beds will be 3' from the west lot line at the closest point. Please refer to the attached test hole logs and plan and profile sheets for the septic design. If this design is followed,there will be no adverse impacts to adjacent properties. Sincerely, N..• 49 TH %\ It Michael E. Anderson, PE 714-4-a-d. Attachments r� Michael E.Anderson:o- #k<2,sfF ,_4381-E s-;1, 4,5i IWZROFES5100,`4. ��) ' GE ENGINEERING PO BOX 240773 ANCHORAGE,AK 99524 522-7773 677-7766(FAX) October 22,2018 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Knik View Estates,Tract C—22351 Judd Drive Separation Distance Waiver Absorption Bed to Lot Line Dear On Site Services Engineer: A section of the proposed absorption bed on the subject lot must be placed at 3' from the westerly lot line due to the proximity of the proposed house on the lot and the presence of shallow groundwater. The majority of the bed system is more than 10' from the property line. Soil conditions at this location are composed of clean sand with silt with percolation rates under 1 minute per inch. Very little migration of effluent is anticipated. The adjacent lot is served by a community water system with no well on the lot. In addition, the septic system is more than 40' from the common lot line. We therefore request a waiver be issued allowing the bed to be 3' from the lot line at its closest point. Sincerely, 74/44.L.L.1 -L Michael E. Anderson, P.E. • ar • i 114 • 49th /\ .i •�/ • • L MICHAEL E. ANDERSON • t v ff ••��d>.••,•••.No. CE-4381 s $ p SX*A Aff_b Z > (D _0 6 0 m m C/) Z ( M - ) iMXm cm A �C� z M", m cl) m Or cn cn 0 z C/) C-) cf) < C() 0 --j m O �c, j 0 cf) C? S )o Kr- Om<---jm000m ob 0 ommor>-nor-mO 0 c:m - > or- r- > m 'o 0 0 r- o m m M 0 M z Q2 m m 0 0 IM cn > m m C/) Z ( M - ) iMXm z <m 0 ---i cf) cyl 0 ---i cf) -u �u 0 D m > m m :;a i m cf) S 0 )o Kr- Om<---jm000m ob 0 ommor>-nor-mO 0 c:m - > or- r- > m 'o 0 0 r- o m m M 0 M z Q2 m m 0 0 moosNm m c>o -mn cn� cl) 0 m cn m, Z 0 0 co m > G) 0 03 )< > 0 < x 0 m Z0 m -0 X OO m ...... 0 W — m M m < :n 0 m z 0 � z m x :5 m -.,0 >- G-) 0a m 0 IN, > 0 m — q (s) :>2 C-) IF1 x Z> 00 C() X 0 0 0 G x > 08 c m :E z 0 M M W m ;a (=> m m a) C= < a, c') 0 'r -'N >. 'o C= x M Z -n > (-- L 0c/) = 0 -j z cn 0 00 2:0a M 0 m --i m m= co 0 > ma C) m m -C,\ E , C? m C, Z x 0 m 0 C/) cf) c, -n r- M 0 0 ox HOM --q 5�� -n -n E;: a > > -n G) m IT m 0 0 0 m M0 0 =6 Z\ cf) C() --i m m 0 m z > z 0 m n 0 C= m x m m m > m c/) > m cl) m m m z 30 PUBLIC ACCESS EASEMENT IM cn > m m C/) Z ( M - ) iMXm z <m moosNm m c>o -mn cn� cl) 0 m cn m, Z 0 0 co m > G) 0 03 )< > 0 < x 0 m Z0 m -0 X OO m ...... 0 W — m M m < :n 0 m z 0 � z m x :5 m -.,0 >- G-) 0a m 0 IN, > 0 m — q (s) :>2 C-) IF1 x Z> 00 C() X 0 0 0 G x > 08 c m :E z 0 M M W m ;a (=> m m a) C= < a, c') 0 'r -'N >. 'o C= x M Z -n > (-- L 0c/) = 0 -j z cn 0 00 2:0a M 0 m --i m m= co 0 > ma C) m m -C,\ E , C? m C, Z x 0 m 0 C/) cf) c, -n r- M 0 0 ox HOM --q 5�� -n -n E;: a > > -n G) m IT m 0 0 0 m M0 0 =6 Z\ cf) C() --i m m 0 m z > z 0 m n 0 C= m x m m m > m c/) > m cl) m m m z 30 PUBLIC ACCESS EASEMENT TRACT C, KNIK VIEW SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: 450 GPD PEAK FLOW BED SYSTEM PERK RATE: <1 MIN/IN 1,250-GAL S.T.E.P. TANK APPLICATION RATE: .7 GPD/SF 2' MOA APPROVED SAND 450 GPD/ .7 GPD/SF /15' WIDE = 42.85 LF TRENCH REQUIRED (44 LF SPECIFIED) BOTTOM OF BED: 2' BELOW GRADE FLOW LINE ELEVATION: 1.5' BELOW GRADE TOP OF BED: 1' ABOVE GRADE GRADE TO DRAIN 1' — =111=111=111=1 I I=111= 11=111=1II—!II-111=111=1Ii-1 = -•���_ = _ =111=111=111=111=111=111=111=111=111=1I = _ e.._ OGIII=III=III=III=III=11i=III=III—III—II --- 2" INSULATION & OG -111111=111-111-111-11 E-111= _—zmo 1 GEOTEXTILE FABRIC 2' DRAINFIELD ROCK 1" PERFORATED PVC (HOLES DOWN) 2' MOA APPROVED SAND 5-3/16" HOLES PER LATERAL (30 TOTAL) 3.4' ON CENTER. 2.5' 5' 5' 2.5' r r + I 15 1 TYPICAL BED SECTION (NO SCALE) GE RNG INFE RING :4\iii ,.?P4 ' •'' meg: 'f'.9th NOTES: *:49•T•�j./\ ..: 1. GRADE AREA OVER BED TO DRAIN AWAY 410>V . ,�e .i 2. PROVIDE 3' OF COVER OVER BEDS AND 4' OVER SEPTIC TANK, OR 2' WITH 2" 9 '. Michael E.Anderson . OF INSULATION ,r �csO0831- ��$�,�•'�` e 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER +iF�FDoROFESSIOtiP < THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY MUNICIPALITY OF ANCHORAGE ,■-=,(� !4CIV��+ DEVELOPMENT SERVICES DEPARTMENT 4614P STM �*rl • �� 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 *• ,. SOILS LOG AND PERCOLATION TEST . 8enja ' hiller••:•.„, ��,�E��j' CoEa n io592 .• J' . LEGAL DESCRIPTION:TROYI DAV IS ESTATES LCI tAVPR\"`, PERFORMED FOR: Professional Engineers Stamp: DATE: 10/03/18 PROJECT No.: PARCEL ID#: - TECHNICIAN: J. MILLETTE DEPTH TEST HOLE 1 (feet) 1 SLOPE SITE PLAN — 2' OB 2 • 3 SANDY GRAVEL(GW) 4 . SEE SITE PLAN 6 SILTY GRAVEL(GM) 7 8 •9 10 WAS GROUND WATER ENCOUNTERED? YES 7 IF YES®WHAT DEPTH? I0' DEPTH OF WATER AFTER MONITORING: 9' 11 DATE OF MONITORING: I0/II/18 12 DEPTH TO DATE READING GROSS TIME NET TIME WATER N�T DROP 13 (MINUTES) (MINUTES) (INCHES) (INCHES) BOH 14 10/11 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 1 17:04 6 2 17:34 30 8 2 16 3 17:35 6 17 4 18:05 30 8 2 18 5 18:06 6 19 6 18:36 30 8 2 20 PERCOLATION RATE: 15 (MIN/INCH) PERC.HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 5 FT. and 6 FT. COMMENTS: • MUNICIPALITY OF ANCHORAGE .9F AWN DEVELOPMENT SERVICES DEPARTMENT /�Arikt..` 4� ,9 �� 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 *:497H ". SOILS LOG AND PERCOLATION TEST 0/� �..: Benja.7 hiller . j e' CE •12592 `� LEGAL DESCRIPTION: K N I K VIEW ESTATES LCI Itw`;FePROFESSIUN� �� PERFORMED FOR: TROY DAV I S ��N���`'1 DATE: 10/03/18 PROJECT No.: Professional Engineers Stamp: PARCEL ID#: - TECHNICIAN: J. MILLETTE DEPTH TH1 - PERK2 (feet) 1 SLOPE SITE PLAN 2 3 4 5 SEE SITE PLAN 6 1 7 8 9 10 WAS GROUND WATER ENCOUNTERED? 1F YES®WHAT DEPTH? 11 DEPTH OF WATER AFTER MONITORING: DATE OF MONITORING: 12 GROSS TIME NET TIME DEPTH TO NET DROP 13 DATE READING (MINUTES) (MINUTES) WATER (INCHES) (INCHES) 14 10/11 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 1 17:15 1:06 6/ 12 6 16 2 17:17 1:04 6/ 12 6 3 17:19 1:08 6/ 12 6 17 4 17:21 1:06 6/ 12 6 18 5 17:23 1:08 6/ 12 6 19 6 17:25 1:08 6/ 12 6 20 PERCOLATION RATE: 0.2 (MIN/INCH) PERC.HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 3 FT. and 4 FT. COMMENTS: GRAVEL PERK BETWEEN 3' AND 4' MUNICIPALITY OF ANCHORAGE r� DEVELOPMENT SERVICES DEPARTMENT *b.." %\ 11 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 6650 %% .,_—> s� ••• SOILS LOG AND PERCOLATION TEST d� '= ' ''' '' '''.'' Benja ' chiller r#1`�`/�l4..C0Ed17 25592 ••.�- 18 LEGAL DESCRIPTION: KNIKD VIEW ESTATES LCI tkk OPR FESSio •. PERFORMED FOR: TROY AV S Professional Engineers Stamp: DATE: 10/03/18 PROJECT No.: PARCEL ID#: - TECHNICIAN: J. MILLETTE DEPTH TEST HOLE 2 (feet) 1 1.5'OB SLOPE SITE PLAN L 2 • 3 1 SANDY SILTY GRAVEL(GW) 4 • 5 SEE SITE PLAN L, 6 ,C/y,, 7 DENSE SILT 8 9 I SANDY SILTY GRAVEL(GW) 10 WAS GROUND WATER ENCOUNTERED? YES �. IF YES @ WHAT DEPTH? 6' DEPTH OF WATER AFTER MONITORING: 6 11 • DATE OF MONITORING: 10/I I/18 12 DATE READING GROSS ENET M TTIMDEPTH To WATER NET DROP 13 (MINUTES) ) (INCHES) (INCHES) 14 10/11 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 1 16:21/16:22 1:30 6/ 12 6 16 2 16:23/16:24 1:32 6/ 12 6 3 16:25/16:26 1:34 6/ 12 6 17 4 16:27/16:28 1:28 6/ 12 6 18 5 16:29/16:30 1:30 6/ 12 6 19 6 16:31/16:32 1:31 6/ 12 6 20 _ PERCOLATION RATE:0.25 (MIN/INCH) PERC.HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 2 FT. and 3 FT. COMMENTS: „t' "r” Municipality of Anchorage s. ', ,, On-Site Water and Wastewater Program + ' P.O. B —itil i I i a' ox 196550 4700 Elmore Road . . :; lard Anchorage,Alaska 99519-6650 Phone: (907)343-7904 Fax: (907)343-7997 .., , , . . '„.HOP,„.„ ...,..t)))Cr)t Review Comments Engineer: FORGE ENGINEERING 10/24/2018 Legal Description: KNIK VIEW ESTATES TR C Parcel ID: 05104302000 Permit: OSP181383 WellSeptic Report Type: On-Site Review Completed By: R.Carroll The application has been reviewed and the following comments have been generated. These are to be satisfactorily addressed prior to MOA approval: 1. Records indicate that there is (or was) a community well on this lot. Please address whether or not it is still there or confirm it has been properly decommissioned. 2. There is public water routing down Judd Drive. Please confirm that a well is desired. a) If well is desired, an additional $215 fee is required for the drainfield to lot line waiver request. b) If well is not desired, please remove references in narrative and on site plan. 3. Narrative states that adjacent lots are vacant. Most of the adjacent lots are developed. Please address. 4. If design switches to public water, note that the 10 ft separation between the water service line and drainfields shall be maintained (including proposed alternate drainfield). 5. Confirm a minimum 10 ft separation from the drainfields to any subsurface drains (i.e. foundation drains). 6. Site plan note for alternate drainfield is missing the drainfield width. Please address. 7. Address tank buoyancy. 8. Under"System Requirement" on the section drawing, please correct the tank size. 9. Please confirm on-center spacing of holes in distribution piping, called out on section drawing. 1. No well is currently in place on the lot and no evidence can be found of a well casing. 2. The water service line remains on the property. It is shown on the Site Plan. The developer intends to continue the use of this service. N well will be placed. 3. The narrative has been revised. 4. The note has been added. 5. The absorption beds are more than 10'from the foundation. At this time the developer is not contemplating footing drains. A note has be( added however requiring the 10' separation. 6. Corrected. 7. The highest water table noted is 6'. Calculations indicate the tank will not float. A note has been added however to anchor tank as required. 8. Corrected. 9. Corrected. MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section - Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 051-043-62 1. GENERAL INFORMATION Expiration Date: /' ! 01 Complete legal description Knik View Estates, Lot C-1 Location (Site address) 22339 Judd Drive Chugiak, AK 99567 Current property owner(s) Mailing address Real estate agent Troy Davis Homes Day phone 310-2501 1689 Knik Goose Bay Rd. #400 Wasilla, AK 99654 2. TYPE OF DWELLING: Fx_1 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ❑ Private Septic 0 Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System 0 Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ � o Waiver Fee $ Date of Payment t% o�5 19 Date of Payment Receipt Number Receipt Number COSA # 0 S C i 9% l.3 7 Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering Phone 907-522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage AK 99503' Engineer's Printed Name Michael E. Anderson, P.E. Date 5/9/19 OF 49th ®®�� 6. DSD SIGNATURE System #1 Approved for 1 0........................................:..�,. y pp V bedrooms ��n? MICHAEL E. ANDERSON System #2 Approved for bedrooms ®oz's''• ��• CE -4381 : �® Y pp o®o'Fp% 5/9/19 .•••'`F��'® Disapproved®® 0�'OROFESS\St®�•®• Conditional approval for bedrooms, with the following stipulations: �ll(m(( wlrf 1V ON-SITE VVXrER ANDm �SR WASTEWATER oz PROGRAM By: Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage'is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet Legal Description: COSA Checklist Knik View Estates, Lot C-1 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Comments Public Water System B. TANK DATA Age of tank(s) `1 years Tank type/material STEP / Steel Measured operating fluid level in septic tank N/A Al Standpipes/foundation cleanout per record drawing Date of pumping New Tank Parcel ID: 051-043-62 Structure served by this system Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by Date of Sample C. LIFT STATION ❑ Required maintenance completed Age of lift station `1 years Lift station material Steel Comments: D. ABSORPTION FIELD DATA Mounded bed Which system tested (date installed) 31$119 Adequacy test date ❑E ALL standpipes present per record drawing Results ❑ Pass For bedrooms Total measured depth from grade 4 ft (max) Fluid depth prior to test in Measured depth to pipe invert from grade ft (min) Water added gal ■❑ N/A — pressurized field New depth in 0 Monitor tubes go to bottom of effective. If not, state depth into effective Elapsed time min ❑■ Code -required soil cover over field Final fluid depth in ❑ System presoaked Absorption rate gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) date of test) Gallons introduced N/A gallons If yes, enter date Comments/Deficiencies: New Septic system. COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) ❑ Yes Septic Tank/Lift Station on Lot > 100' NSA Community Sewer Manhole/Cleanout > 100' NSA F1 Yes if No ft ❑ Yes if No ft Neighboring Tank > 100' ❑ Yes if No NSA ft Private Sewer/Septic Line > 25' ❑ Yes if No NSA ft Absorption Field on Lot > 100' ❑ Yes if No NSA ft Holding Tank > 100' ❑ Yes if No NSA ft Neighboring Absorption Fields > 100' NSA Animal Containment > 50' ❑ Yes if No NSA ft ❑ Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ❑ Yes if No NSA ft F1 Yes if No NSA ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑✓ Yes if No ft Surface Water > 100' ❑✓ Yes if No ft Property Line > 5'✓❑ ❑ Yes Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ❑✓ Yes if No ft Private Wells > 100'✓❑ Yes if No ft Water Main > 10'✓❑ ft Yes if No ft Community Wells > 200' ✓❑ Yes if No ft Water Service Line > 10' ✓❑ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ❑ Yes if No 9.3 ft If absorption field is under driveway comment below Property Line > 10' ❑ Yes if No 3.0 ft Wells on Adjacent Lots: Water Main > 10'✓❑ Yes if No ft Private Wells > 100' Q✓ Yes if No ft Water Service Line > 10' ❑✓ Yes if No ft Community Wells > 200' ❑✓ Yes if No ft Surface Water > 100'✓❑ Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION I certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet F No �• 49th �'®® u9un.0 10 ■ ..nu........... .............. nu..........■ MICHAEL E. ANDERSON • �v e No. CE -4381 ��®TC�,p `'•., 4/22/19 •.•°• Cv�� CLQ °0j•........a••11 � .� e�t000ROe®S®®®�® �®