Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DENALY ESTATES BLK 2 LT 6
Onsite File #067-062-13 Municipality of Anchorage On-Site Water and Wastewater Program ° (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP191081 PID Number: 067-062-13 Dwelling: FIC Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: 0 New ❑ Upgrade Name: Troy Davis Homes ABSORPTION FIELD ❑ Deep Trench © Shallow Trench ❑ Bed ❑ Mound Address 1689 Knik Goose Bay Rd 400 Wasilla, AK 99654 ❑ Other Phone Number of Bedrooms Soil Rating ITotal depth from original grade 310-2501 4 1.2 GPD/SF 1.05-3.45 / 1.05-3.45 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 0.55-2.95 / 0.55-2.95 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot Denaly Estates 2 6 Fill added above original grade 0.0-2.5 / 0.0-2.6 Ft. Gravel length 2 @ 50 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 500 Ft 2 2 >6 Ft. Well >100' >100' N/A N/A >25' TANK ElSeptic X S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 11500 Gal. surface water >100' >100' N/A N/A Material Number of compartments Lot Line >5' >10' N/A N/A Steel 2 NA Foundation >10' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Anchorage Tank 250 Gal. Remarks Trenches are insulated. Pump on level atain 13 mp off level at 5 in. High water alarm at 11 in. Pump make and model PF2005 Electrical Inspections performed by Powertec Electric LLC Installer PIPE MATERIAL House to tank D3034 Tank to drainfield D3034 Ursa Minor Landscaping Drainfield D3034 CO/MT Inspector J.Mlllette / J. Williams BENCH MARK (Assumed elevation) 100 ft Inspection 151 8/29/19 8/29/19 Location and description 2�d 3rd 4th Bottom of siding on SE wall at point A. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Conditional Approval: Date .a•°°"°°°°°°°•>. AW G9 to ...... .....a.....a- - .......................... °saa°°vaasaa°aam°°.°®azc°v°aaaeeve;`} . MICHAEL E. ANDERSON jll No. CE-4381 a' 1 A0/2/19 Approved pp k Date 1 c p �� e E`* inspection meporr_a-i-it.aoc DENALY ESTATES, BLOCK 2, LOT 6EXfSTING WELLEXISTING WELL� 1,500 GALLONSTEP TANK4-BDRM HOMEEFFECTIVE DEPTH...... 11, 110 pis ABSORPTION TRENCHESALTERNATE SITE: CATEGORY III0.5'EFF. DEPTH ABS. TRENCH EXISTING WELLAPP. REATE 6 GPD/SFMTMTLOT 6 O 50 100 �111110 OM iIIIIIIE MM FEET � \ ~ � � `. � 8 LEGEND 2CO 39.6 12.0 svi 42.1 17.45 SV2 45.3 23.2 MH 46.5 25.2 MT1 24.2 57.4 MT2 73.1 CO'CLEANOUT 2CO'DOUBLE CLEANOUT FCO ' FOUNDATION CLEAl' MT-MON|TOR|NGTUBE � SV'SEPTIC VENT � TH'TEST HOLE ®ENALY ESTATES BLOCK 2 LOT 6 VV.V 99.5 WEST TRENCH ORIGINAL 2 GRADE 97.1 ORIGINAL GRADE �-- 99.6 FINISH GRADE n 1 2" INSULATION 96.55 DRAINFIELD ROCK ' 96.55 11796.05 96.05 1 50' IL-- 85.1 GROUNDWATER 9/27/19 86.1 N r 99.5 EAST TRENCH ORIGINAL ►- GRADE 97.1 ORIGINAL GRADE 99.7 FINISH GRADE 2" INSULATION 96.55 DRAINFIELD ROCK 96.55 96.05 96.05 j-® 50' 85.1 GROUNDWATER 9/27/19 86.1 N k �",a��t���® • e ffi • 49th MICHAEL E. ANDERSON 4 PROFILE AS -BUILT O. CE -4381 as"° ENGINEERING (NO SCALE) �� 4p °d•P�'�� V'- heaton ater V,,40 1190 N. Wasifla-Fishhook Road Wasilla® AGS 99664 10n'71a-71-_ '*bA— Name: i– Troy Davis Homes Address: 1689 S Knik Goose Bay Rd. ##400 City: Wasilla State: AK Zip Code: 99654 Well Site: Denaly Estates Lot/Block: 6/2 Additional: Well Depth: 141 ft. From: To: Formation: 0 4 sand/silt Below Ground: 139 ft. 4 8 sand/silt/gravel Above Ground: 2 ft. 8 16 wet samd/silt Gal/Min: 60 gpm 16 28 silt/gravel 28 44 silt/gravel/cobble Static Level: Artesian 44 64 silt 64 86 clay hard Casing: 141 ft. of 6 in. x.25 in. steel 86 117 clay soft 117 135 clay/cobble/gravel Liner Pipe: N/A 135 141 grvel/water Screened: N/A Perforated: N/A Grouted: 5 bags of Bentonite Depth: 20 plus ft. WATER QUALITY; Develop. Method: Air Colif©rm ' � < titrates (3,,k3 Use of Well: Residential Arsenic j0 q Drilling Method: Rotary Cather: well chlorinated to 50ppm The well was pumped 5' off the bottom with 100% draw down for 2 hours and recovered at 60 gpm gpm. Date Drilled: 4/15/2019 DrillE Ben Mattson iTING 4u100ML /L L 10 22 11 Development Services Department Building Safety Division G On -Site mater At Wastewater Program 4700 Elmore Road r P.O. Box 196650 „Y MarkBegich Anchorage, AK 99507 Ns n H r r Mayor www.muni.ora/onsite (907) 343-7904 Pump Installation Log Well Drilling Permit. Number: SW Date of Issue: Parcel Identification Number: Legal Description Property Owner Name & Address, Denaly Lot 6, Block 2 Troy Davis Homes Inc 1689 Knik Goose Bay Rd Wasilla, AK. 99654 Pump Installation Date: No submersible Pump. Pump Intake Depth Below Top of Well Casing: Pump Manufacturer's Name: Pump Model: Pump Size hp Pitless Adapter Burial Depth- 12 feet Pitless Adapter Manufacturer's Name: Campbell Pitless Adapter Installer: WeIl.Disinfected Upon Completion? ❑ Yes ❑ No Method of Disinfection: C07311nents: Artesian well. Jet pump installed in house Pump Installer Name: Nowell pump installed feet Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. \ \ \ \ 'A / / / / / / I / / / / / / / W O W L) Q z Lij V) O O O _ aEcm i c E -r °+ IL Q o m o° 0 N II X �a`Em °opo o w a o c Z 'G oLn 07 YLZm O E a K 17 r Z m o n c 0 4ovZo e umx> c Q °° mn OIO JO C'I C4 — C N N In In Z u o o ° T O _ aEcm i c E -r °+ a Q o m o° c o o o m �a`Em °opo o cmo J N o c Z 'G oLn 07 YLZm O E a K 17 Q� n N T a°� amo + y d V n c o 4ovZo e umx> c Q °° mn V N C'I C4 C N N In In C04, 1"a OL oO a ' O O Cc ° OC mg Oc va°E 70E zoi ° ommamocooc 0N LO L 0 E— 9 :E m me >` czIc+EL cn G ° C *a mo , 7� O vW�♦^i i °; mol0 `°a+°t°oo �O vEm � U oC V t %% m a 3 a o V TAY O X mQn L�}`.`0a ° cv 0 E3 mm W a ma c Xm O t F- J •J n r V C E E Ma T L L m V) L Z »nom 0 . a OC N Q _ p 0 In Ct0 I ]. O 0 O1• c! O p �O n Y 0.acna n C� TU "-OmLm�C m oar mmix cO z �(D ' o° IL OE tO°«m°c5 a» m r« ° L 0002Em 90 nm a CL L 3 a o C o J < c S MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP191081 Work Type: WellSeptic Initial Tax Code Number: 06706213000 Site Legal Address: DENALY ESTATES BLK 2 LT 6 G:0362 Site Mailing Address: 25356 MC INTYRE RD, Eagle River Owner: TROY DAVIS HOMES INC Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date Expiration Date Lot Size in Sq Ft: Total Bedrooms: » ''ent S, �c� l�epartn�enr 4/4/2019 4/3/2020 54810 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska - Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) - - 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: 1. The recorded plat for this subdivision notes that artesian wells are common and that special drilling methods may be required to prevent waste of water via surface discharge. 2. A percolation test is required in the GM layer shown on the test holes between 1 and 3 feet below original grade. a) If the percolation rate is less than 1 mpi, either a sieve shall be provided to demonstrate that the soil is GM, or a 2 ft sand filter shall be provided. b) If the percolation rate is more than 5 mpi, construction shall stop pending On-site review and approval of a change order. 4 C ^ 0 r 4-o at p, "j S I 4 CArc_� , — P—MC 6/1-7/11 Received By: Date: Issued By: Date: ?IJSat/ MUNICIPALITY OF ANCHORAGE sf 897, j Community Development Department 0- Development Services Division . F.". 'I- - /3-7• On-Site Water & Wastewater Program d APR 0 3 2019 i" ON-SITE SEWER/WELL PERMIT APPLICATIO a ti c) 0168 L. 9 Parcel I.D. 067-062-13 Property owner(s) Troy Davis Homes Day phone 310-2501 Mailing address 1689 Knik Goose Bay Rd #400, Wasilla, AK 99654 Site address NHN McIntyre Road Chugiak, AK Legal description (Sub'd., Block & Lot) Denaly Estates, Block 2, Lot 6 Legal description (Township, Range & Section) Lot Size 54,810 Sq. Ft. Number of Bedrooms -Fo(1K•(y) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial X Single Family (SF) 'XI (w/wo ADU) Septic Tank X Upgrade ❑ Duplex (D) n Holding Tank Renewal Multiple Dwellings Privy ❑ (SF and/or D) Private Well I XI Water Storage I I THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. --144,1,1, a a t (Signature of property owner or authorized agent) Permit/Rush Fees: 4 /3/a. Waiver Fees: Date of Payment: L � 9 Date of Payment: 0. 1-14?-1)' '�/n Receipt Number: a� '[� Receipt Number: Permit No. 65/94168/ Waiver No. Permit App_:-:• !, ) ' GE ENGINEERING PO BOX 240773 ANCHORAGE,AK 99524 522-7773 677-7766(FAX) April 3, 2019 MOA Development Services Dcpt, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Denaly Estates, Block 2,Lot b—NHN McIntyre Rd. Septic System Design Dear On-Site Services Engineer: The owner of the above lot intends to build a 3-bedroom home on the property.We are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home and the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system on this lot or adjacent lots. The ground surface on the lot slopes gently to the southwest at grades approximating 20%. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Drainage arrows are shown on the site plan indicating the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trenches will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100' from all wells and surface water, and more than 5' away from the septic tank. Please refer to the attached test hole logs, soils lab analysis, plan and profile pages for the septic design. If this design is followed,there will be no adverse impacts to adjacent properties. Sincerely, • it✓ lX tic ""�— ti f L ........�7♦� IC Michael E. Anderson, PE ; }• 4t •'•'� • • at/; M.ICHAEL E. .ANQER5ON 's •Ct h0. CE-4381 •A<",F 4/3/19 0..•kt� DENALY ESTATES, BLOCK 2, LOT 6 � 1 STING WELL 15' T// (E EASEMENT 12.5' BLIIl 61NG SETBACK / PROP 1,500 GALLdN STEP TAN / LOT / \ \ 4-BDRM HdME / FCO 1 10' DRAINAGE EASEMENT 2-50' LONG x 5' WIDE x.5' / EFFECTIVE DEPTH ABSORPTION TRENCHES ;ENGINlE RING 100' WELL RADII / PROPOSED WELL (NOT YET DRILLED) v,yoME ALTERNATE SITE: CATEGORY 111 SYSTEM WITH 20'L X 5'W X.5' EFF. DEPTH ABS. TRENCH. APP. RATE 6 GPD/SF. LOT 5 i PROPOSED SEPTIC AREA FOR LOT 5 IS >100' FROM PROPOSED SEPTIC SITE FOR LOT 6 NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE LEGEND PROPOSED SEPTIC SYSTEM CO - CLEANOUT ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS 2CO - DOUBLE CLEANOUT PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC FCO - FOUNDATION CLEAN SYSTEMS. MT - MONITORING TUBE 0 50 100 SV - SEPTIC VENT ME ME FEET TH - TEST HOLE DENALY ESTATES, BLOCK 2 , LOT 6 DESIGN FACTORS: SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW 5' WIDE TRENCH SYSTEM PERK RATE: <1 MIN/IN 1,500-GAL STEP TANK APPLICATION RATE: 1.2 GPD/SF 600 GPD /1.2 GPD/SF /5' WIDE*1.0 RED. FACTOR = 100 LF TRENCH REQUIRED (100 LF SPECIFIED) BOTTOM OF TRENCH: 1.0' BELOW GRADE FLOW LINE ELEVATION:0.5' BELOW GRADE TOP OF TRENCH: 2.0' ABOVE GRADE PLACE 4" OF TOPSOIL AND REVEGETATE MOUND -�I-IHEI II—III=ET=1T= --fri=I I I=III=ITI=I I I=1 1TI= 2'-0" -1T�TTI-1 11=1 I(-M-I I -11 I M=1 1I- =T=T 1TI=1 I I Tf 1=1 11=1TI=1 11-1 11= - I 1=1 I M-Mf T- -I TSI -I 1TI ITT ITT-M- 2" INSULATION 1-111—ITI—T=1 11-I 1 1=1TI-ITT TTI-I 11-Tff-T-1 I 4-=.-1 I1-T-III-T-1II-T-1I I- -M-TIP -III- -M-M=ITT-17-TIT-M=1 11-17=1 I IT1= III-1 11=1 11 --T=1TI-T-1 11-I I _111=11 = I I III=1I1=III=III=T T. 1TI-T=1 -III-II1E1II= 1=111=11 .fI_T_ttt!re rierStreir. _tstt!//_/_!. l= m 6„ :.:::::::::•:::.:::j:::::::.::::::: :_::::::::.::. ORIGINAL GROUND j:::::::...:...:.:.:::::`:11:11::::01 1101:.:11::::::11 6., .:.:.:.:::::.:.:::.:.:.:::::::•:.:.:.:::::::::.:.. 1' PERFORATED PVC } (HOLES DOWN) 15-3/16" HOLES PER LATERAL @ 3.33' 5 DRAINFIELD ROCK ' GE !..?ENGI NE EKING TYPICAL TRENCH SECTION ...G TJ`r . z', (NO SCALE) � : .... C:qy�� a • + 1111.;9' • NOTES: x= 49i- � • � 1. GRADE AREA OVER TRENCH TO DRAIN AWAY i •'�Etr „..+ 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK. OR 2' • . MICHAEL E ANDERSON . • WITH 2" OF INSULATION •142,1'• No. CE-4381 r 1111, S�, (- 4,319 ,.•'•N� 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER Tip'••• ... 1111 THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY .-re*II I% ok.*.•� 'e&®®� Tito ® too LO .••� p ®�. Q® W i.� LO Oi C s o� L z 'O o U) oLO 0 LO m F- �� z (n W a o w ;m o � (n O i W <cnN 0 c� LO Q o W •x C) W O Q N m O W V) O N t0 O LO O O N O NN co O U) O (0 N N N N W i.� o� SOILS LOG AND PERCOLATION TEST '�`•`� �� %..*O. GE 49th T'''}ff���� r1.... ip EE0.1 NG ,• ` 0 vo F:,MICHAEL E. ANDERSON .Li a ••c-s; No. CE-4381 ...•'__ LEGAL DESCRIPTION: DENALY ESTATES B2 L6 .1�et.... ..4:3.19' ...•''cce�'4.. PERFORMED FOR: TDH ��h� OFESS\1.4' DATE: 3/2 7/19 ,1�������� PROJECT No.: PARCEL ID#: 067-062-13 TECHNICIAN: J. MILLETTE Professional Engineers Stamp: DEPTH TEST HOLE 1 (feet) 1' OB SLOPE SITE PLAN 2 '.r.'..'....: GM (SANDY SILTY GRAVEL) 4 5SEE s—E P_AN 6 SP (COARSE SAND) 7 8 9 - - V z CL/ ML 10 (CLAY/SILT) WAS GROUND WATER ENCOUNTERED? YES BOH IF YES @ WHAT DEPTH? 9' S 11 DEPTH OF WATER AFTER MONITORING: 7' 0 DATE OF MONITORING: Z./3/19 E 12 GROSS TIME NET TIME DEPTH TO NET DROP 13 DATE READING (MINUTES) (MINUTES) WATER (INCHES) (INCHES) 14 3/27 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 1 7:40/7:40 <10 sec 4"/ 10" 6" 16 2 7:41 / 7:41 <10 sec 4"/ 10" 6" 3 7:42 /7:42 - - - 17 4 7A3/7A3 - - - 18 5 7:44/7:44 - - - 19 6 7:45/7:45 <10 sec 4"/ 10" 6" 20 PERCOLATION RATE: <1 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4 FT. and 5 FT. COMMENTS: �•.-4-\ ...2.'.....414-14•••i GE SOILS LOG AND PERCOLATION TEST %�` •49th **t.*•�/ EN 61NFE RING 7 t � �O\MICHAEL E. ANDERSON J i •��•. S, N o. CE-4381 /=: LEGAL DESCRIPTION: DENALY ESTATES B2 L6 vi,�F,p'•.. 413/19 r•.e'r4.'•. PERFORMED FOR: TDH �4.114��'ROF`S„ 1:••• lk- DATE: 3/27/19 PROJECT No.: PARCEL ID#: 067-062-13 TECHNICIAN: J. MILLETTE Professional EngineersStamp: DEPTH TEST HOLE 2 (feet) "F.-^ 1' OB SLOPE SITE PLAN 1 • t'• 2 r GM (SANDY SILTY GRAVEL) 4 5 6 SP (COARSE SAND) 7 8 9 10 Q WAS GROUND WATER ENCOUNTERED? YE S IF YES @ WHAT DEPTH? 10' I 1 DEPTH OF WATER AFTER MONITORING: 8.5' BOH DATE OF MONITORING: 4/3/19 E 12 GROSS TIME NET TIME DEPTH TO NET DROP 13 DATE READING (MINUTES) (MINUTES) WATER (INCHES) (INCHES) 14 3/27 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 1 7:20/7:20 <10 sec 6"/0" 6" 16 2 7:21 /7:21 <10 sec 6"/0" 6" 3 7..23/7:23 - - - 17 4 7:24/7:24 - - - 18 5 7:25/7:25 - - - 19 6 7:26/7:26 <10sec 6"/0" 6" 20 PERCOLATION RATE: <1 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4 FT. and 5 FT. COMMENTS: " ` NORTHERN GEOTECHNICAL ENGINEERING, INC,/ TERRA FIRMA TESTING `¢ Laboratory Testing Geotechnical Engineering Instrumentation Construction Monitoring Services Thermal Analysis F F PROJECT CLIENT: Forge Engineering %GRAVEL 16.2 USCS SP PROJECT NAME: Denali %SAND 82.9 USACOE I'C N/A PROJECT NO.: 4914-18 %SILT/CLAY 0.9 %PASS.0.02 mm N/A SAMPLE LOC.: TH-2 %MOIST.CONTENT 2.6 %PASS.0.002 mm N/A NUMBER/DEPTH: • Lot 6 UNIFORMITY COEFFICIENT(Cu) 3.8 DESCRIPTION: Poorly-graded sand w/gravel COEFFICIENT OF GRADATION(Ce) 1.1 DATE RECEIVED: 3/29/2019 ASTM DI557(uncorrected) N/A TESTED BY: JA ASTM D4718(corrected) N/A REVIEWED BY: RJPC OPTIMUM MOIST.CONTENT.(corrected) N/A oa.ai PARTICLE SIZE ANALYSIS WCOMS ASTM D422/C136 100 6 i 7/ J U2118 f(11 1440 am rm 1160 Nlip e o SIEVE ANALYSIS RESULT I. il SIEVE SIEVE TOTAL% SPECIFICATION 90 t SIZE(mm) SIZE(U.S.) PASSING (%PASSING) 80 .*' 1 — 152.40 G` —__— 76.20 3" 70 __ 38.10 1.5" 100 60 , .�-I---._.__— _-._.__ -- 19.00 3/4" 0 crfl 8 I 4_11_i •— 12.70 112" 96 50 i 9.50 3/8" 92 m 40 _ J " _— 4.75 #4 84 a —j— 2.00 #10 59 30 1 0.85 #20 21 w 20 ♦ _ E 0.43 #40 5 10 , , 0.25 #60 1 0.15 #100 1 0 - _ 0.075 #200 0.9 100 10 1 0.1 0.01 0.001 GRAIN SIZE(mm) HYDROMETER RESULT GRAVEL f SAND ELAPSED DIAMETER TOTAL% CODDLES Ir ( SILT or CLAY TIME(MIN) (mm) PASSING Cease Fine Comae Medum Pine O 0.5 • I MOISTURE-DENSITY RELATIONSHIP ASTM D1557 2 4 145 -1--— —I— - I g { IS 140 30 60 135 M _ _-- �— _ : T I 2500 • j i 130 HYDRAULIC COND. N/A A l (ASTM D2434) A125 — DEGRADATION N/A 120 (A'I'M T-313) i PLASTICITY INDEX N/A 115 ASTM 4318 0 2 4 6 8 10 12 14 16 MOISTURE CONTENT(%) The testing services reported herein have been performed to recognized industry standards,unless otherwise noted. No other warranty is made. Should engineering interpretation or opinion be required,NGL-TFT will provide upon written request. 11301 Olive Lane • Anchorage,Alaska 99515 • Phone:907-344-5934 • Fax:907-344-5993 • www.nge-t.com MUNICIPALITY OF ANCHORAGE Development Services Department P P �- � Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 067-062-1 1. GENERAL INFORMATION Expiration Date: `1 Complete legal description DENALY ESTATES BLOCK 2, LOT 6 Location (site address) 25356 MC INTYRE ROAD, EAGLE RIVER, AK 99577 Current property owner(s) DOMINIQUE MARIE COOPER Day phone Mailing address Real estate agent 25356 MC INTYRE ROAD, EAGLE RIVER AK 99577 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ® Private Septic Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. Date: COSA Fee $ 50 Waiver Fee $ Date of Payment (!57-- / 7— ZU ZZ Date of Payment Receipt Number 31 -7/ 32- Receipt Number COSA # 0 3 C a a% 0/ T Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Address 13030 SUES WAY, ANCHORAGE, AK 99516 Engineer's Printed Name CURTIS HUFFMAN, PE Date 3/15/2022 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to d�`�1 these various and dynamic characteristics and are outside the control of the evaluator of the I'�•q well and septic system. Therefore, any estimate of how long a system will function satisfactory Idw • . • ! t for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & S/ *:.� TM '.* Fwrs 6. DSD SIGNATURE % " . — "' �" Curtis Huffman System #1 Approved for bedrooms CE 128991W, y Approved for bedrooms �iwhOPR,FESSIO_w"Co' System #2 A ROO , Disapproved lllll(tcfrr��� Conditional approval for bedrooms, with the following Stip Y OF -SITE WASTr_v'AT ER Jap GF.AIV[ '��J�FNT tG�SO. 1)1)1)i))li��' By: TaLOriginal Certificate Date: 3-249-2-022 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other Legal Description: DENALY ESTATES, BLOCK 2, LOT 6 Parcel ID: 067-062-13 If more than 1 septic system on lot: COSA Checklist # _of _ Structure served by this system A. WELL DATA ® Well log is filed with Onsite (or attached) Well production at time of test 4+ gpm Date drilled 4/5/2019 Water storage tank volume NA gallons Total depth 141 ft Well disinfected for coliform test? ❑ Yes ® No Cased to 141 ft ® Coliform bacteria is Negative ® Sanitary seal is functioning correctly Nitrate mg/L ® Nitrate less than MRL (ND) ® Wires are properly protected Arsenic ug/L ® Arsenic less than MRL (ND) Casing height (above ground) 18+ in. FW' Date of flow test for COSA 3/15/22 Collected by <=- Static water level at beginning of test Date of Sample 3/1622 Comments *ARTESIAN PLUG BELOW SANITARY SEAL. WHEATON WATER WELLS SHOWS 60GPM. B. TANK DATA C. LIFT STATION Age of tank(s) 2.5 years ® Required maintenance completed Tank type/material STEP / STEEL Age of lift station 2.5 years Measured operating fluid level in septic tank * Lift station material STEEL ® Standpipes/foundation cleanout per record drawing Comments: *FLOATS / SEE MAINT. REPORT Date of pumping 3/15/2022 STEP MAINTENANCE REPORT: 3/21/22 Which system tested (date installed) 8/29/2019 ® ALL standpipes present per record drawing Total measured depth from grade 3.5+ ft (max) Measured depth to pipe invert from grade _ft (min) ® N/A — pressurized field ® Monitor tubes go to bottom of effective. If not, state depth into effective Adequacy test date 3/15/2022 Results M Pass For 4 bedrooms Fluid depth prior to test 0 in Water added 600 gal New depth 1 in Elapsed time <15 min ® Code -required soil cover over field Final fluid depth 0 in ❑ System presoaked Absorption rate 600 gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) N date of test) Gallons introduced gallons If yes, enter date Comments/Deficiencies: FW`' E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ® Yes if No Community Sewer Manhole/Cleanout > 100' If absorption field is under driveway comment below ® Yes if No ft ® Yes if No Neighboring Tank > 100' ® Yes if No ft Private Sewer/Septic Line > 25' ® Yes if No _ Absorption Field on Lot > 100' ® Yes if No ft Holding Tank > 100' ® Yes if No Neighboring Absorption Fields > 100' F. ENGINEER'S COMMENTS Animal Containment > 50' ® Yes if No ® Yes if No ft _ Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ®Yes if No ft ® Yes if No From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ® Yes if No ft Surface Water > 100' ® Yes if No Property Line > 5' ® Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ® Yes if No ft Private Wells > 100' ® Yes if No .14/iter Main >.10.' _ , _ Yes if No ft Community Wells > 200' ® Yes if No Water Service Line > 10' ® Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ® Yes if No ft If absorption field is under driveway comment below Property Line > 10' ® Yes if No _ ft Wells on Adjacent Lots: Water Main > 10' ® Yes if No ft Private Wells > 100' ® Yes if No ft Water Service Line > 10' ® Yes if No ft Community Wells > 200' ® Yes if No Surface Water > 100' ® Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION .-GNP, l certify that 1 have determined through field inspections and review ���(�Q.: •' } of Municipal records that the above systems are in conformance g ' •:'� q with MOA COSA guidelines in effect on this date. .. ....... ® ..'� Curtis Huffman �� �F� •. CE 128991 }�lIF�Fop 128/2 - * AN .s ROfESS10 ft ft ft ft ft ft ft ft MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Lift Station/Pump Vault Owner Street Addressi Septic Tank: -Sludge level inches -Pumping: required es no -Pumping completed e no Lift station: -Pump basket cleaneds no -Effluent filter cleaned e ' no -Control floats cleaned ves no -Proper float settings confirmed es: no -Operation satisfactory 6e no Alarm System: -Dedicated electrical alarm circuit es ` no •Audible and visual alarm inside dwelling � no -Alarm system operation satfsrac�"orv. not satisfactory{ Manhole Riser -Ground water intrusion at riser to tank connection es n -Ground water intrusion around pipe penetrations Ves na -Weep hole functionalesf no -Manhole lid: Functionale , no Insulatedes no Properly Secured es = no Other -All manufacturer required inspections and maintenance completed yes no Comments: Qualified Maintenance Provider: Technician�j4r" Company i-. S .Set's' Signature Date of maintenance C tNc, i '17, Date's -1 l Ept)9-A49 MUNICIPALITY OF ANCHORAGE Development Services Department ;, Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Parcel I.D. 067-062-13 Certificate of On -Site Systems Approval 1. GENERAL INFORMATION Complete legal description 25356 Mc Intyre Road Chugiak, AK Location (site address) Expiration Date: v� 0 Denaly Estates, Block 2, Lot 6 Current property owner(s) Mailing address Real estate agent Troy Davis Homes Day phone 907-357-9394 1689 Knik Goose Bay Rd, Ste 400,,Wasilla, AK 99654 2. TYPE OF DWELLING: Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: 4 TYPE OF WASTEWATER DISPOSAL: Private Well 0 Private Septic' 0 Water Storage ❑ Holding Tank. ❑ Community Well ❑ Community . ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. } COSA Fee $ /010 Waiver Fee $ _ Date of Payment 11 W 19 Date of Payment Receipt Number NMM Receipt Number COSA # o 6C 1 R 159 Waiver # 6. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below,;) verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site,to verify the information submitted. Name of Firm Forge Engineering Address 1399 W 34th Ave Suite 101, Anchorage AK 99503 Engineer's Printed Name Michael E. Anderson, P.E. 6. DSD SIGNATURE _Z_ System #1 Approved for _1L bedrooms System #2 Approved for bedrooms Disapproved Phone 907-522-7773 Date 11/6/19 Conditional approval for bedrooms, with the following stipulations: .0�'-It � \lY 0FAZft1_, WATER ANn {AIA n-rr, , n..___ %i�J��►!T SERV�G`����`, By: 67m kA ,, J Original Certificate'' Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Septic System Advisory Well Flow Advisory COSA Checklist blue sheet Nitrate Advisory Arsenic Advisory Other Legal Description: Denaly Estates, Block 2, Lot 6 If more than 1 septic system on lot: COSA Checklist # A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 4/5/19. Total depth 141 ft Cased to 141 ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) >24 in. Date of flow test for COSA 4/5/19 Static water level at beginning of test ft. Comments B. TANK DATA Age of tank(s) "-1 years Tank type/material S.T.E.P./Steel Measured operating fluid level in septic tank ❑ Standpipes/foundation cleanout per record drawing Date of pumping New Construction - 8/29/19 D. ABSORPTION FIELD DATA 5' Wide Trench Which system tested (date installed) 8/29/19 ❑ ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) ❑ N/A — pressurized field ON Monitor tubes go to bottom of effective. If not, state depth into effective Parcel ID: 067-062-13 of Structure served by this system Well production at time of test 60 gpm Water storage tank volume 0 gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate •130 mg/L ❑ Nitrate less than MRL (ND) Arsenic 1109 ug/L ❑ Arsenic less than MRL (ND) Collected by Wheaton Water Wells Date of Sample 10/22/19 C. LIFT STATION ❑ Required maintenance completed Age of lift station �1 years Lift station material Steel Comments: New Construction - 8/29/19 Adequacy test date New Construction Results [] Pass For bedrooms Fluid depth prior to test in Water added gal New depth in Elapsed time min ❑ Code -required soil cover over field Final fluid depth in ❑ System presoaked Absorption rate gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) _ date of test) If yes, enter date Gallons introduced gallons Comments/Deficiencies: *Total depth from finished grade 3.55 to 3.65. COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ✓1 Yes Community Sewer Manhole/Cleanout > 100' r, Yes if No ft 7✓ Yes if No ft Neighboring Tank > 100' Yes if No ft Private Sewer/Septic Line > 25' F, Yes if No ft Absorption Field on Lot > 100' 0✓ Yes if No ft Holding Tank > 100' ✓/ Yes if No ft Neighboring Absorption Fields > 100' Yes if No Animal Containment > 50' ✓V Yes if No ft M✓ Yes if No ft if No ft F. ENGINEER'S COMMENTS Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' M✓ Yes if No ft 0 Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0✓ Yes if No ft Surface Water? 100' ®✓ Yes if No ft Property Line > 5' ✓1 Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' [✓ Yes if No ft Private Wells > 100' Yes if No ft Water Main > 10' ❑✓ Yes if No ft Community Wells > 200'✓� Yes if No ft Water Service Line > 10' Q✓ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' U✓ Yes if No ft If absorption field is under driveway comment below Property Line > 10' F✓ Yes if No ft Wells on Adjacent Lots: Water Main > 10' ❑✓ Yes if No ft Private Wells > 100' ®✓ Yes if No Water Service Line > 10' M Yes if No ft Community Wells > 200' Yes if No Surface Water > 100' 0 Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION 1 certify that I have determined through field inspections and review Of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet ft ft