Loading...
HomeMy WebLinkAboutSOUTHPOINTE BLK 3 LT 8 Onsite File Southpointe Block 3 Lot 8 #020 - 311 - 66 Municipality of Anchorage On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP191074 PID Number: 020-311-66 Dwelling: ❑ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑ Upgrade Name Crown Pointe, Inc. ABSORPTION FIELD ❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound Site Address 6506 Southpointe Ridge Drive ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 229-1886 4 6.0 GPD/SF 6.5 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 6.0 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot Southpointe 3 8 Fill added above original grade 0.3 Ft. Gravel length 25 Ft. Township Range Section Gravel width 5 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 125 FF Ft. Well >50' >50' N/A N/A >25' TANK ❑ Septic ❑ S.T.E.P. ❑ Holding Fmil Other Manufacturer Orenco / Advantex (FAP) Capacity 1,500 Gal. Surface Water >50' >50' N/A N/A Material Number of compartments Lot Line >5' >10' N/A N/A NA Fiberglass 2 Foundation *9.5' >10' N/A NIA LIFT STATION Manufacturer Capacity Remarks *See attached septic profile. Gal. Alarm location Electrical installed by PIPE MATERIAL House to tank D3034 drainfield Tank to D3034 Installer Northern Excavation Drainfield D3034 CO/MTD3034 Inspector J. Millette BENCH MARK (Assumed elevation) 100 ft Inspection15' 4/26/19 8/2/19 Location and description 2�d Garage slab. 3rd 4`h ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp OF Conditional Approval: Date 'm��P,.°••' 49th aysvvav//}},++ 0 ................................................ r°MICHAEL E. ANDERSON d ♦ % No. CE-4381 ®�®TF,p'•..,0�10/5/20 Septic System Approved cajvx Y/,)7&)( Date .•°°'tt�� Fp.... Note: this approval does not include well permit requirements. .... �����r���®-���® �® (Rev VD/UL/ 16) SOUTHPOINTE, BLOCK 3, LOT 8 PERMIT # OSP191074 PID # 020-311-66 31.9 MW \ SOUTHPOINTE 32.3 RIDGE DRIVE \ 15' T&E EASEMENT yyj 2CO 29.8 38.4 C01 \ —��--- 28' DRIVEWAY EASEM 50' WELL RADII (2008-052829-0) \ s '. • yy ; •' . DRIVEWAY EASEMENT ' ' , • ' � • ' I • y� (2011-024327-0) EXISTING WELL ✓, TTH2 ALTERNATE SITE \ — — 25' LONG x 5' WIDE x \ CO2 i 0.5' EFFECTIVE DEPTH \ r ABSORPTION TRENCH \ col 2C0 \ \ 1500 -GAL MH2 \ \ ADVANTEX TANK \ \ \ � B 4'BEDRppMN MH1 W/ AX20 POD � I \ pM� AFco LOT 9 �� THE WELL ON THIS LOT IS MORE THAN 50' \ EX�STIN&WELL \ \ FROM THE PROPERTY LINE. y�LO_T8\�,--_�, \\\ \ �2 \ �F ti A B GE ENGINEERING PLAN AS -BUILT 0 50 100 EEL— M FEET 111=50' FCO 5.4 31.9 MW 12.6 32.3 MH2 22.7 35.3 2CO 29.8 38.4 C01 41.1 29.2 CO2 1 62.7 35.8 MT 62.8 34.9 I LEGEND CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE Permit Number: HSW191074 Date of Issue: 4-10-19 Parcel Identification Number: 02031166000 Date Started: 6-15-19 Date Completed: 6-18-19 Is well located at approved permit location? x Yes ❑ No Legal Description: Southpointe Block 3 Lot 8 Property Owner Name & Address: Crown Pointe Inc PO Box 112313 Anchorage, Alaska 99511 Borehole Data: Depth (ft) Method of Drilling x air rotary ❑ cable tool Soil Type, Thickness &Water Strata From To Casing type: steel stick-up 0 2 cobbly gravelly silt 2 14 bedrock 14 268 WATER "tratas _I • g A ZJ I ZO Wall Thickness: .250 inches Diameter: 6 inches Depth: 22 feet Liner Type: Diameter: inches Depth: feet Casing stickup above ground: 2 feet Static water level (from ground level): 151 feet Pumping level: 267 feet after 2 hours pumping 5 gpm Recovery Rate: 5 gpm Method of Testing: air li t Well Intake Opening Type: ❑ Open End x Open Hole ❑ Screened Start feet Stopped feet ❑ Perforations Start feet Stopped feet Grout Type: bentonite granules Volume: 5 bgs n --+I,. 'I ().fPPf CtnnnPd 7n fPnt Pump: Intake Depth feet Pump size hp Brand Name IIWell Disinfected Upon Completion? x Yes ❑ No Method of Disinfection: chlorine tablets Comments: 4.5 pvc was installed from 12' to 52' with a shale paker at the bottom at 52'. Bentonite granules were deposited and hydrated from 20' feet to52' Well Driller: Alpine Drilling & Enterprises PO Box 110496 Anchorage AK 99511 U b U., L' Li I J k1l Li: -Ii k1_1 d t 4 J..' U Z 1_-M1LLiNk_1 MUNICIPALIT T %JF ANCHORAGE it Phone: 907-343-7904 Development Semllce.s Department On -Site VV-citer & Wastewater 'SectionFax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: 191074 Daft ofls'que':4 ParcelIdenfificat.imi Number: 020311_66V,-<'_) Legal De-veriptiva 1-Alock 1Lut oproj proper Owner Name & Address. "y Pr I 'I ointe, inc, $0uthpointVfe w 18 11P.0, Box 112313 Anchwaoe, AK 99511-2313 purup Installation Date. 10 __-z —_2015 Pump Intake Depth BelvivTop of IVDU C-Hsing: 252____ feet Pump Manufacturer's NMAke, Pump',Nlodel.• 10SH10 Pump Size; - I hp Goulds Pities Adapter BurW Depth - N/A feet NIA Pitless Adapter Manufactnrer's Namt: — __ Pitless Adapter Installer: WA Well DL,Oectad Upon Completiuk(? Ves 77 No Method of -Visinfectimc.ahlorine tablets Comments; PLEASE SAVE FOR CO,' 3 3A. Pump 1ja0aller Name' Aarow Pump & Well Service, L.LC P.0, Box 11049 6 Anchorage f r1st.,ader sball pro'Vide a pump instal laticin iog to On-�te within 30 d:Vs 0 _13MIT installation. Received Date/Time 05/11/2020 15:52 05/11/2020 15:30Collected Date/Time 1201832001 Matrix SGS Ref.# Client Sample ID Southpointe B3 L8 Client Name Project Name/# Printed Date/Time 05/18/2020 14:00Forge Engineering Inc. Technical Director Stephen C. Ede Southpointe B3 L8 Drinking Water Sample Remarks: Parameter Results LOQ Units Method Allowable Limits Prep Date Analysis Date InitContainer ID Metals by ICP/MS ACF05/12/20EP200.8ug/LArsenic 05/12/20ND5.00 (<10)B Microbiology Laboratory ACF05/11/20SM21 9223B100mLE. Coli Negative 1 A ACF05/11/20SM21 9223B100mLTotal Coliform Negative 1 A Page 2 of 6                                             !" #$ % "$!$&'($) * +!! ,-!  $ % . +!/$$ .0 .    )1 %+$2.345  66 )72&8 9 !2282 3450   :+ )  0 !2;+ :+ )  9 !0 !<  % $;+  N,""""r,. MUNICIPALITY OF ANCHORAGE �� On-Site Water&Wastewater Program Shm, tbwe'` PO Box 196650 4700 Elmore Road . Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997http://www.muni.org/onsite\ ':"' !, y N. mcnt 4 hcHORP°. On-Site Water & Wastewater System Permit Permit Number: OSP191074 Effective Date: 4/10/2019 Work Type: WellSeptic Initial Expiration Date: 4/9/2020 Tax Code Number: 02031166000 Site Legal Address: SOUTHPOINTE BLK 3 LT 8 G:3738 Site Mailing Address: 6506 SOUTHPOINTE RIDGE DR, Anchorage Owner: CROWN POINTE INC Lot Size in Sq Ft: 117846 Design Engineer: FORGE ENGINEERING Total Bedrooms: 4 This permit is for the construction of: RI Disposal Field 0 Septic Tank 0 Holding Tank 0 Privy El Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: pt The entire subsurface disposal field and/or alternate is not within a 30 foot radius of a percolation test. The ngineer needs to do an additional percolation test prior to the construction of the septic field. Please submit v tamped and signed results with the As built Inspection Report. If the results require a design change, /con tion of the system will stop pending On-Site review and approval. /god 0 G1 5/gA CO ) , 1 a1 S/1 Received By: i1HWLT7l1f9( j) Date: I G iii I t Issued bi- IN ....✓ Date: Vo//ei R U3 9 891 MUNICIPALITY OF ANCHOR A 497' RUSH rr t 1'i 3' Community Development Department N1 P rete: 907-343-7904 ti w Development Services Division r - 907-343-799 A On-Site Water & Wastewater Program r 1w ; << 01 6 9 L 9 ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 020-311-66 Property owner(s) Crown Pointe, Inc. Day phone 229-1886 Mailing address P.O. Box112313 Anchorage, AK 99511 Site address NHN Southpointe Ridge Drive Anchorage, AK 99516 Legal description (Sub'd., Block & Lot) Southpointe, Block 3, Lot 8 Legal description (Township, Range & Section) Lot Size 117,846 Sq. Ft. Number of Bedrooms Four (4) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (Z all that apply) Absorption Field I X1 Initial X Single Family (SF) 'XI (w/wo ADU) Septic Tank 'XI Upgrade Duplex (D) n Holding Tank n Renewal Multiple Dwellings Privy ❑ (SF and/or D) Private Well ❑X Water Storage I I THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. 444,--SLS atA—t9----\ (Signature of property owner or authorized agent) Permit/Rush Fees: 4/1312. eWaiver Fees: a-as fi las- Date of Payment: `l(2-11 1 Date of Payment: 1 a 1l 9 Receipt Number: ( 51$3 Receipt Number: 65'g3,D Permit No. ()SP Iq 103-' Waiver No. OS V Iq IUO$ Permit App_.-.• : ...c cow-) �,) ' GE ENGINEERING PO BOX 240773 ANCHORAGE,AK 99524 522-7773 677-7766(FAX) May 14, 2019 MOA Development Services Dept, On-Site Water& Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Southpointe,Block 3,Lot 8—NHN Southpointe Ridge Septic System Design Dear On-Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property. We are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home and the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system on this lot or adjacent lots. The ground surface on the lot in the area of the absorption trenches is relatively flat. Contours are shown on the site plan indicating the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. The trench will be placed in a 10-15 year old fill section. The fill is composed of clean sandy gravel which was obtained during the development of the subdivision from the local area. The material is identical to the soil lense directly beneath the fill and has naturally consolidated over the past many years. The discharge of effluent from the Advantex Treatment System into this fill section will be have the same effect as if discharged into the naturally occurring underlying material. Effluent will flow through the sand filter layer and then to the material below with no adverse impact to the environment. Wells on this and adjacent lots are shown. The new system will be a minimum of 50' from all wells and surface water, and more than 5' away from the septic tank. Please refer to the attached test hole log and plan and profile sheets for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, ••••••OF '% 14/k....L.Q, L-t9---1 Michael E. Anderson, PE % ;• 40th ` ''. ++ i r.I . ...�101 ,� • ++ MICHAEL E. ANDERSON i = +� 44 NO. CE-4381 . � ••',lei::S:: •• SOUTHPOINTE, BLOCK 3, LOT 8 COO- i I \ \ N / J \\ \\ \� \ — /< •/' \\ \ SOUTHPOINTE \ \/S' \ \\ RIDGE DRIVE • : ' N 15'T&E �.,/ \ N EASEMENT //�j I // \ \\ �\ •// ..S' S / \ \ •�-- �// 28'DRIVEWAY EASEMENT 50'WELL 14AD11 .: y (2008-052829-0) I — — \ S DRIVEWAY EASEMENT • ' •. .. • ' •• yi (2011-024327-0) EXISTING WELL ___/ .21 ,�• \ / ( / \ • `( / 02 \ I \N 1 // •• ALTERNATE SITE A 25'LONG x 5'WIDE x \ \ ,� 0.5'EFFECTIVE DEPTH • ABSORPTION TRENCH \ \ \ \ / //•F`I 2C0 1500-GAL / MH \ ADVANTEX TANK \ \ — W/AX20 POD PFI9POSED 6\LL 4'BFDROOMNO FCO \ ME LOT 9 \ \ \ \ •1 THE WELL ON THIS LOT IS MORE THAN 50' N \ N \ FROM THE PROPERTY LINE. \\\\ N\ \ \ ----.1_____1111184/1/ 1 LOT 8 - _ -� , , \ / ti°�sT\ - ` � / \ \ \ \ ` (If?, \\ \ N \ / F N t� \ N _ F�''c�,gs\� \\ \ / � _ � � ` FMF�T\\\ �\ / N \ \ \ _ \\ \ f \ \\ NI \ \it \ \ \ \ I GE \ ENGINEERING,. NOTE. \ , \ \ \ I 40.. i• NO SLOPES>25%WITHIN 50'OR SURFACE WATER WITHIN 100'OF THE LEGEND ••.-\E............... PROPOSED SEPTIC SYSTEM ..�1SP,.•• ,.S.i. CO-CLEANOUT 1 i\•�°•yI.-�. ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS 2CO DOUBLE CLEANOUT S • 49th e i FCO-FOUNDATION CLEANOUT .. .... ... . • PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC • � � •�-• FS-FLOW SPLITTER VALVE •i. MICHAEL E. ANDERSON . •• •r.�•' SYSTEMS. MH-MANHOLE •t1 s,1... No. CE-4381 rpt{=. 0 50 100 MT-MONITORING TUBE v♦,�F�•y.•.5/14/19 ..."l 4, I� - FEET SV-SEPTIC VENT N.PRoFE5;;�• 1"=50' TH-TEST HOLE SOUTH POINTE, BLOCK 3, LOT 8 DESIGN FACTORS: SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW 5'WIDE TRENCH SYSTEM PERK RATE: <1 MIN/IN 1,500-GAL FAP ADVANTEX SEPTIC TANK APPLICATION RATE: 6.0 GPD/SF AX-20 FILTER POD 600 GPD/6.0 GPD/SF/5' WIDE *1.0 RED. FACTOR = 20 LF TRENCH REQUIRED (25 LF SPECIFIED) BOTTOM OF TRENCH:6.5' BELOW GRADE FLOW LINE ELEVATION: 6.0' BELOW GRADE TOP OF TRENCH: .5'ABOVE GRADE 6" =11 11 lmllooi 1111 -II iqii I* *11 11*11" SII II*II=lll0l 5.5' - � 11,111 =V14111411 IIRII*11011: =1�1 * *1111*11011 = -110110110II*11:11= „ 4 PERFORATED PVC (HOLES DOWN) 6" %: %:%=%=%=f •= %=•= 6„ , : : : : : :::.;.: : : DRAINFIELD ROCK 2' MOA APPROVED SAND INor GE ENGINEERING TYPICAL TRENCH SECTION q • (NO SCALE) +�P�E.,..........Cq" a ` 49th %` • 17 NOTES: ' � • 1. GRADE AREA OVER TRENCH TO DRAIN AWAY %'!-�s.�. te --• 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' • MICHAEL E. ANDERSON WITH 2" OF INSULATION t��' •., No. cE-43S1 ir' "� 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER �.• eo'•....................5/10/19 .•�c� '++ THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY �1•6� isS *�• 46 nP TGE SOILS LOG AND PERCOLATION TEST %{x 49tn �" • INGINIIIIING , �{/ -, MICHAEL E. ANDER l,,r■ ILO..A...No. cE-43et e LEGAL DESCRIPTION: SOUTHPO INTE B3 L8 -.A o./28/19 crit PERFORMED FOR: CROWN POINTE -404,e6%........ R°1� ILII .� DATE: 5/19/18 PROJECT No.: • PARCEL ID#: 020-311-66' TECHNICIAN: N. SHAFER Professional Engineers Stamp: DEPTH TEST HOLE 1 (feet) 1 S_OPE SITE ELAN 2 ,. 3 ROCKY GRAVEL FILL •5 —.:'..:1!:.::', .r, :4j SEE SITE PLAN rya 7 '":•se ri SANDY SILTY GRAVEL 9 R� y : .,f_.;".. �<r.;r;��,ty?•�' WAS GROUND WATER ENCOUNTERED? NO 1 0— tZe.:Z St'71 IF YES(n WHAT DEPTH? S ��".fp•'SG DEPTH OF WATER AFTER MONITORING: NONE 0 11' I,f,k t ' '' r t_,..-->. u'.. , DATE OF MONITORING: 21/18 12 •i a:. ;,t�": DEPTH TO ;K;`i''w DATE READING GROSS TIME NET TIME WATER NET DROP 13 yei�a � (MINUTES) (MINUTES) (INCHES) (INCHES) 14 i''"'"' 7/21 TEST HOLE PRESOAKED PRIOR TO TES-ING: BEDROCK 15 1 12:08/ 12:18 10 41976 516 2 12:20/ 12:30 10 4/816 416 16 3 12:31 / 12:41 10 4 18;-0o 411i° 17 4 12:42/ 12:52 10 4/816 416 18 5 12:53/ 13:03 10 4/816 4 6 19 6 13:05/ 13:15 10 4/86 416 20 PERCOLATION RATE: 2.4 (MIN/INCH) PERC.HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 6 FT. and 7 FT. COMMENTS: air CV 4�' SOILS LOG AND PERCOLATION TEST `�� " ° �� R i 49th GE , z ; ENGINEERING ,. L.w..rrrrr.. •. .=.V..S s MICHAEL E. ANDERSON 1 �•J''. No. CE-4381 .��[_� LEGAL DESCRIPTION: SOUTHPOINTE B3 L8 s6-?(FI,'... �.van-94381...0V m19 8.•.''F '•• PERFORMED FOR: CROWN POINTE ���pROFESs���:��� DATE: 5/19/18 PROJECT No.: PARCEL ID#: 020-311-66 TECHNICIAN: B. SCHILLER Professional Engineers Stamp: UI:PTII TEST HOLE 2 (feet) SLOPE SITE PLAN 2 " • 3 , FILL- SANDY GRAVEL 4 5 SEE SITE PLAN 6 7 SANDY SILTY GRAVEL 9 BEDROCK 10 WAS GROUND WATER ENCOUNTERED? NO IF YES @ WHAT DEPTH? - DEPTH OF WATER AFTER MONITORING: NONE 11 DATE OF MONITORING: 7/2 /l8 12 GROSS TIME NET TIME DEPTH To NET DROP 13 DATE READING (MINUTES) (MINUTES) WATER (INCHES) (INCHES) 14 15 16 17 18 19 20 PERCOLATION RATE: (MIN/INCH) PERC. HOLE DIA. (INCHES) TEST RUN BETWEEN: FT. and FT. COMMENTS: Ar')."i *lltiiitGE SOILS LOG AND PERCOLATION TEST ;,4h 49th 1` •'' tENGINEERING e. ..E.. �• • f73.%t.MIICHHAAEL E. ANDERSON r °.� No. CE-4381 ��=,i LEGAL DESCRIPTION: SOUTHPOINTE B3 L8 �. (4,1... 5113)19 "eal PERFORMED FOR: CROWN POINTE �hietim�sS\ •� DATE: 4/29/19 PROJECT No.: PARCEL ID#: 020-311-66 TECHNICIAN: J. WILLIAMS Professional Engineers Stamp: DEPTH TEST HOLE 3 (feet) i °_.:. NO ORGANIC LAYER SLOPE SITE PLAN 2 3 GP - POORLY GRADED 4 • SANDY SILTY GRAVEL 5 J • SEE SITE PLAN 6 7 SUBDIVISION AND ON SITE I"'"' ~, MATERIAL PLACED AS FILL 8 ;' 3: 9 1.0 .�.'. ', WAS GROUND WATER ENCOUNTERED? NO IF YES 0 WHAT DEPTH? - 1 1 '. DEPTH OF WATER AFTER MONITORING: NONE i DATE OF MONITORING: 5/9/19 12-•': :*:.4r.'.; .• .. DEPTH TO DATE READING GROSS TIME NET TIME WATER NET DROP 13 (MINUTES) (MINUTES) (INCHES) (INCHES) 14 •;•••:-.'1-:•' ^- '-•..w 4/30 TEST HOLE PRESOAKED PRIOR TO TESTING: "''•,.. .: GM/GP - SANDY SILTY GRAVEL 15 1 3:00/3:01 1 6/0 6 16 2 3:05/3:06 1 6/0 6 3 3:08/3:09 1 6/0 6 17 4 3:11/3:12 1 6/0 6 18 • -' - BOTTOM OF HOLE 5 3:15/3:16 1 6/0 6 19 6 3:16/3:17 1 6/0 6 20 PERCOLATION RATE: <1 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 2 FT. and 3 FT. COMMENTS: Soil absorbs water much faster than 1 minute per inch. Sand liner required. IIIIMIL. MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT,herein the"AGREEMENT"made and entered into as of this Day of Q p/-r4 of 20/?,by and between td&E-T_TweiLn2e440,09-*Aerein the"OWNER,"and the MUnicipality of i e .. , AnchOrage,herein the"MUNICIPALIT,_Y",in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The MuniCipality•grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System.(AWWTS); Advantex System described as located at(legal description) Southpointe Block 3 Lot 8 2. Maintenance.Repairs and Alterations. (Owner is required to read,understand and initial each section) Throughout the term of this Agreement,the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative, The AWWTS shall be triaintained in a satisfactory condition capable of perfotrning as designed and producing,treated septic effluent in - accordance with the equipment's approval for operation in the Municipality. jr7A -. It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s),maintenance;adjustment(s),replacement Costs,and inspection costs. This " includes an annual maintenance fee(typically $400 to$600). _..., Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, re airs or permitted alterations to'the system. Owner acknowledges that regular maintenance of an AWWTS reduces the potential q failure of the systems which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of 3 `—Owner acknowledges that the Municipality may requestrecords of maintenance and repairs from the manufacturer's representative or maintenance provider. Owner acknowledges that the fine for failing to maintain and repair an.AWWTS may be assessed inaccordance with AMC 14.60.030. _ . Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hournotiae; Owner agrees that.any sale or transfer of title of the property will.not occur Without a.new Certificate of On-Site Systems Approval. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the.governing guidelines for the construction,maintenance and repair of:the Owner's AWWTS. Owner agrees to maintain remote monitoring of the AWWTS as rewired by the AW WT'S approval. 3. Term. The term of.this Agreement shall begin on the date of approval by the Municipality to operate the.installed system,or upon transfer of title,and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. 'The failure of the Municipality at any time to enforce a provision of this Agreement shall in.no way constitute.a waiver of the provisions,nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement.shall only be.amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising_from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage: The laws of the State ofAla'ska shall govern the rights and obligations of the parties under this Agreement. 7, Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 OWNER: fi Iry • (signature) bate: 1 IAJ/4-1./cr i›-Z.. (,J e-t L) (print.name) STATE OF ALASKA ) ) ss. THIRD JUDICIAL DISTRICT ) G n .. The foregoin instrument was acknowledged before me this Q day of(�' y[�,Q , 20 /9 by Hmy Cruel 10 "`��� 000014440,4 NOTARY BLIC FOR.ALASI{A :#otv �1,. 1 � �My Commission expires: ,� ), Commisss®� Franklin County, �;%;��?tory 8, ®� �o� MUNICIPALITY: Ssiion gigots By: &RI �,-f.---- (signature) Date: 117/tOct (print name) Title: • • (rev. 05/18/2018) Page 3 of 3