Municipality of Anchorage
On -Site Water and Wastewater Section • (907) 343-7904 �'� 1 of 3
ON-SITE WASTEWATER INSPECTION REPORT ,� }
OSP191168 050-315-31
Permit Number: PID Number: '
49
Dwelling: X Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: [I New ❑ Upgrade
Name
Troy Davis Homes Inc.
ABSORPTION FIELD
❑ Deep Trench A Wide Trench ❑ Bed ❑ Mound
Site Address
18741 Roseberry Park Dr. Eagle River, AK
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
(907) 357-9394
5
1.0 GPD/SF
3.7/3.5 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
3.2/2.9 Ft.
Gravel depth beneath pipe
0.5/0.6 Ft.
Subdivision Block Lot
Roseberry Park Estates 1 6
Fill added above original grade
0.2/0.1 1Ft.
Gravel length
2 @ 75 Ft.
Township Range Section
Gravel width
5.0 Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION
DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
750 Ft z
2
>6 Ft.
Well
>100'
>100'
N/A
N/A
>25'
TANK 9 Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer Capacity
Anchorage Tank 1,500 Gal.
Surface Water
>100'
>1 00'
N/A
N/A
Material
Number of compartments
Lot Line
>5'
>10'
N/A
N/A
NA
Steel/Epoxy Coated
2
Foundation
>10'
>1 0'
N/A
N/A
LIFT STATION
Manufacturer
Capacity
Remarks Tank, and line going to and from tank are insulated.
Gal.
Alarm location
Electrical installed by
PIPE MATERIAL House to tank D3034 drainfield Tank to
D3034
Installer
Whitters Excavation
Drainfield D3034 CO/MTD3034
Inspector J. Mlllette / L Tidwell
BENCH MARK (Assumed elevation) 100 ft
Inspection
15` 8/30/19 9/4/19
dates:2n
Location and description
31tl 9/5/19 4th .J
Top of foundation @ SW house corner.
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
,/
Conditional Approval: u&C1(-0 (Ivuz y foo
q ®e1
OF 14
®i
Se40
Date -3
d•�P�..................
add j oha 30t (aDye r 40 Yee J &_8 oVk c yne weS+
� �'� 49th � =�•®0
.� ;•MICHAEL E. ANDERSON ; c��
s % No. CE -4381 ,•• ��
Septic System
Approved
pp Date®'gyp°••.,,•.2/5/20
Note: this approval does not include well permit requirements.
•.•••''���'�:
�® 440, FESc\O�®��®®
®e%%_
(Rev u5iu2n 8)
ROSEBERRY PARK ESTATES, BLOCK 1 LOT 6
PERMIT # OSP191168
PID # 050-315-31
o� EAST TRENCH
U�;
98.6 FINISH GRADE
- 98.4 ORIGINAL GRADE
95.2 DRAINFIELD ROCK
94.7 MOA APPROVED SAND FILTER
Tt
2" INSULATION
ti 92.7 751 92.7
r-
88.4
NO GROUNDWATER 9/04/19
F --o
2�iU
WEST TRENCH
0� 99.0 FINISH GRADE �0
n n - 98.4 ORIGINAL GRADE n n
95.5 DRAINFIELD ROCK
95.2 MOA APPROVED SAND FILTER
92.9 751 92.9
r-
88.4
NO GROUNDWATER 9/04/19
GE
ENGINEERING
PROFILE AS -BUILT
(NO SCALE)
95.2
94.7
95.5
94.9
Wheaton Water Wee, 8nc.
1190 N. Wasilla-Fishhook Road
Wasilla, AK 99654
(907)376-2041
Name:
Troy Davis Homes
Address:
1689 S Knik Goose Bay Rd. #400
City:
Wasilla
State: AK Zip Code: 99654
Well Site:
Roseberry Park
Lot/Block: 6/1
Additional:
Well Depth:
60 ft.
From: To: Formation:
0 11 cobble/gravel/silty
Below Ground:
58 ft.
11 25 wet gravel/cobble
Above Ground:
2 ft.
25 39 dry silt/cobble
Gal/Min:
8
39 55 wet silt/gravel
55 60 gravel/water
Static Level:
23 ft
Casing:
60ft. of 6 in. x .25 in. steel
Liner Pipe:
N/A
Screened:
N/A
Perforated:
N/A
Grouted:
Benzonite
WATER QUAL.ITY TESTING
I Coliform .1Ke-0, Col/100rr4
Depth:
N/A
Nitrates a. 4 mg/L
Develop. Method:
Air
Arsenic t 3 '7 ati:1�
Use of Well:
Residential
Drilling Method:
Rotary
Misc:
Other:
The well was pumped 5' off the bottom with 100% draw down for 2 hours and recovered at 8 .
Date Drilled:
7/29/2019
Driller: Ben Mattson
Mark Begich
Mayor
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Elmore Road
P.O. Box 196650
Anchorage, AK 99507
www.muni.org/onsite
(907) 343-7904
Pump Installation Log
Well Drilling Permit Number: SW Date of Issue:
Parcel Identification Number:
Legal Description Property Owner Name & Address:
Pump Installation Date:
Pump Intake Depth Below Top of Well Casing: feet
Pump Manufacturer’s Name:
Pump Model:
Pump Size hp
Pitless Adapter Burial Depth: feet
Pitless Adapter Manufacturer’s Name:
Pitless Adapter Installer:
Well Disinfected Upon Completion? Yes No
Method of Disinfection:
Comments:
Pump Installer Name:
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://%vww.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP191168
Work Type: WellSeptic Initial
Effective Date:
Expiration Date:
Tax Code Number: 05031531000
Site Legal Address: ROSEBERRY PARK ESTATES BLK 1 LT 6 G:0154
Site Mailing Address:
Owner: OVERLOOK ASSETS LLC
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
CSI Disposal Field 0 Septic Tank ❑ Holding Tank. ❑ Privy
5/6/2019
5/5/2020
Lot Size in Sq Ft: 47916
Total Bedrooms: 5
C1 Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified ir. Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (2417).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions: The entire proposed drainfield is not within the 30 ft radius of a percolation test. An
additional percolation test is required prior to construction of the drainfield to confirm percolation rate. If results
require a design change, construction shall stop pending Onsite review and approval of a change order. Please
submit results with the inspection report.
Ni %I t9i I.
ads {Z, coar S, V�'C�- . i" c
Received By, Date:
Issued By: Date:
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 050-315-31
Property owner(s) Overlook Assets, LLC
Mailing address 17673 Shasta Circle Eagle River, AK 99577
Site address NHN Roseberry Park Drive Eagle River, AK
Day phone 310-2501
Legal description (Sub'd., Block & Lot) Roseberry Park Estates, Block 1, Lot 6
Legal description (Township, Range & Section)
Lot Size 47,916 Sq. Ft. Number of Bedrooms Five (5)
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(E all that apply)
Absorption Field
❑X
Initial ❑X
Single Family (SF)
❑X
AD U)
Septic Tank
NUpgrade
El(w/wo
Duplex (D)
❑
Holding Tank
❑
Renewal ❑
Multiple Dwellings
❑
Privy
❑
(SF and/or D)
Private Well
❑x
Water Storage
❑
THIS APPLICATION
INCLUDES
A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 1 Isla Waiver Fees:
Date of Payment: J 3 1 `i Date of Payment:
Receipt Number: O3gg`1� Receipt Number:
Permit No. Waiver No.
Permit App_'.;- : ._..:c
PO BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
May 4, 2019
MOA Development Services Dept, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: Roseberry Park Estates, Block 1, Lot 6 – NHN Roseberry Park Drive
Septic System Design
Dear On-Site Services Engineer:
The owner of the above lot intends to build a 5-bedroom home on the property. We are submitting
this permit application for the construction of a new well and septic system. The attached site plan
identifies the location of the home and the proposed well, septic location and alternate site. No
conflicts exist between this proposed system and any other well or septic system on this lot or
adjacent lots.
The ground surface on the lot slopes gently to the southwest at grades approximating 10%. There
are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site.
Ground surface contours are shown on the site plan indicating the grade and direction of flow.
Stormwater drainage will not impact this septic system. The new trenches will be constructed
parallel to the slope as much as possible.
Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all
wells and surface water, and more than 5’ away from the septic tank.
Please refer to the attached test hole log and plan and profile sheets for the septic design. If this
design is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Michael E. Anderson, PE
5/4/19
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP191168, Rebecca Carroll, 05/06/19
ROSEBERRY PARK ESTATES, BLOCK 1 LOT 6
15' ACCESS EASEMENTS
785.0
P OPOSED WELL
LOT 7 N
VACANT LOT 6
LOT 5
2-75' LONG x 5' WIDE x .5' EFFECTIVE
DEPTH ABSORPTION TRENCHES
Co
co -
MT STING EPTIC AREA
MT k "0-64-Att A
77
A 7.5
SEPTIC TA K w/2
TH1 MA AY RI ER
2CO
FS
ALTERNATE SITE: MH F
CATEGORY111TREATMENT
SYSTEM w/30' LONG X 5' WIDE
X.5'EFF. DEPTH TRENCH. IMT co 5-BDRM HOME
APP. RATE 5 GPD/SF
co
PROPOSED EST HO E TO VERIFY
SUBSUR SOI CONDITIONS
5' SNOW STORAGE
EASEMENT
15'T&E EASEM NIT
Lu NOTE:
< SEPTIC TANK MUST BE >10'FROM
-j OVERLOOK DRIVE FOUNDATION AND >5' FROM
C)
ui DECK/STAIR SUPPORTS.
+
cf)
cl)
L/i
NOTE:
;&eNO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE
.
OF A�o
..... ....... PROPOSED SEPTIC SYSTEM LEGEND
CO - CLEANOUT
ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS
2C0 DOUBLE CLEANOUT
...... PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC FCO - FOUNDATION CLEANOUT
SYSTEMS. FS - FLOW SPLITTER VALVE
0...
..................................... MICHAEL E. ANDERSON 1'ij MH - MANHOLE
_,j
No. CE -4381 PF -Z�-: 0 50 100
MT - MONITORING TUBE
.. <' � im ME FEET 6 F0 512/196�� SV - SEPTIC VENT
4�"ROFESS�1"=50' TH - TEST HOLE
10"Zimm
ROSEBERRY PARK ESTATES, BLOCK 1, LOT 6
DESIGN FACTORS: SYSTEM REQUIREMENTS:
750 GPD PEAK FLOW
PERK RATE: .3 MIN/IN
APPLICATION RATE: 1.0 GPD/SF
5' WIDE TRENCH SYSTEM
1,500-GAL SEPTIC TANK
2' MOA APPROVED SAND
TYPICAL TRENCH SECTION
(NO SCALE)
4" PERFORATED PVC (HOLES DOWN)
DRAINFIELD ROCK
5'
6"
3.0'
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
BOTTOM OF TRENCH: 4.0' BELOW GRADE
FLOW LINE ELEVATION: 3.5' BELOW GRADE
TOP OF TRENCH: 0.5' ABOVE GRADE
750 GPD / 1.0 GPD/SF /5' WIDE *1.0 RED. FACTOR = 150 LF TRENCH REQUIRED (150 LF SPECIFIED)
5/2/19
6"
2'
MOA APPROVED SAND
6"
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP191168, Rebecca Carroll, 05/06/19
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE:
PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
TECHNICIAN:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
DEPTH
(feet)
PROJECT No.:
TEST HOLE 1
SLOPE
SLOPE
SITE PLAN
See Site Plan
DATE READING GROSS TIME
(minutes)
NET TIME
(minutes)
DEPTH to
WATER NET DROP
TEST HOLE PRESOAKED PRIOR TO TESTING:
PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH)
TEST RUN BETWEEN: FT. and FT.
COMMENTS:
(inches)(inches)
ROSEBERRY PARK ESTATES B1 L6
3/20/2019
J. Williams
DATE OF MONITORING:
WAS GROUND WATER ENCOUNTERED?
DEPTH OF WATER AFTER MONITORING:
IF YES @ WHAT DEPTH?
YES
10'
None
0.3 6
4 5
050-315-31
OVERLOOK ASSETS
4:23 / 4:25
3/21
1
2
3
4
5
6
1:26 0 - 6" 6"4:27 / 4:29
4:30 / 4:32
4:33 / 4:35
4:36 / 4:38
4:40 / 4:42
OB
CLEAN GRAVEL
5/1/19
Professional Engineers Stamp:
5/2/19
1:43 0 - 6" 6"
1:42 0 - 6" 6"
1:42 0 - 6" 6"
1:40 0 - 6" 6"
1:43 0 - 6" 6"
Perc test done following day - sand filter required.
GP
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP191168, Rebecca Carroll, 05/06/19
MUNICIPALITY OF ANCHORAGE
Afte.
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section - Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 050-315-31
1. GENERAL INFORMATION
Expiration Date: ____JuLne ,
Complete legal description Roseberry Park Estates, Block 1, Lot 6
Location (site address) 18741 Roseberry Park Drive Eagle River, AK
Current property owner(s) Troy Davis Homes Day phone (907) 357-9394
Mailing address 1689 Knik Goose Bay Road #400, Wasilla AK 99654
Real estate agent
2. TYPE OF DWELLING:
❑® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 5
Day phone
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
❑■
Private Septic
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for:
Distance:
Received by:
Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ �$ 1a6
Date of Payment LllglX 76
Receipt Number 6&5-a3J
COSA # a 5 c,-261130
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below,: I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm Forge Civil Engineering Phone 907-522-7773
Address P.O. Box 240773 Anchorage, AK 99524
Engineer's Printed Name Michael E. Anderson, P.E. Date 4/1/2020
6. DSD SIGNATURE
_X_ System #1 Approved for bedrooms
_�1L__
System #2 Approved for bedrooms =�j`'�F�••, 4/1/20
Disapproved �+ *i� ROTE:
Conditional approval for bedrooms, with the following stipulations:
)(� soy I oc vex -�T I)OL- 0Ae d 1VEA + E_
6)Q S4 ` Yen c�k bL1 jw7 e�i�tttuurrr
ON-SITE �v
A kim
By: &V Original Certificate Date: LIA 9 1,2 Lo j)D
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist
Septic System Advisory
Well Flow Advisory
COSA Checklist blue sheet
X Nitrate Advisory i
Arsenic Advisory
Other
COSA Checklist yellow sheet
COSA Checklist
Legal Description: Parcel ID:
If more than 1 septic system on lot: COSA Checklist # of Structure served by this system
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled
Total depth ft
Cased to ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) in.
Date of flow test for COSA
Static water level at beginning of test ft.
Well production at time of test gpm
Water storage tank volume gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by
Date of Sample
Comments __________________________________________________________________________________
B. TANK DATA
Age of tank(s) years
Tank type/material
Measured operating fluid level in septic tank
Standpipes/foundation cleanout per record drawing
Date of pumping
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D. ABSORPTION FIELD DATA ______________________
Which system tested (date installed)
ALL standpipes present per record drawing
Total measured depth from grade ft (max)
Measured depth to pipe invert from grade ft (min)
N/A – pressurized field
Monitor tubes go to bottom of effective. If not, state
depth into effective
Code-required soil cover over field
System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced gallons
Adequacy test date
Results Pass For bedrooms
Fluid depth prior to test in
Water added gal
New depth in
Elapsed time min
Final fluid depth in
Absorption rate gpd
Any rejuvenation treatment (past 12 months)
If yes, enter date
Comments/Deficiencies:
***
***Additional cover to be added to west trench during final grading before 6/30/20.
Roseberry Park Estates, Block 1, Lot 6 050-315-31
8
7/29/19 None
60
60
2.47
>24 FORGE ENGINEERING
7/29/19
23
3/27/20
<1
Septic/Steel/Epoxy Coated
New Construction
5' Wide Trench
9/5/19 New Construction
3.9/3.6
3.4/3.0
COSA Checklist yellow sheet
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
From Septic/Holding Tank on Lot to:(Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Property Line > 5’ Yes if No ft
Absorption Field > 5’ Yes if No ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10’ Yes if No ft
Property Line > 10’ Yes if No ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
If absorption field is under driveway comment below
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
F. ENGINEER’S COMMENTS
G. ENGINEER’S CERTIFICATION
I certify that I have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
4/2/2020
✔✔
✔
✔
✔
✔
✔
✔
✔✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔