Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
POTTER CREEK TR 1
Onsite File Cree,"..,'. Potter ' t . Traci"h "I a I.- MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP191322 Work Type: Wel]Septic Initial Tax Code Number: 02027104000 Site Legal Address: POTTER CREEK TR 1 G:3640 Site Mailing Address: Owner: BESECKER MICHAEL & NICOLE Design Engineer: FORGE ENGINEERING This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date Expiration Date: J�ZEtlY I7epa�•ti:neut 7/31/2019 7/30/2020 Lot Size in Sq Ft: 3267000 Total Bedrooms: Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing + be &vo ►11 s �� Ie rte, -�-� �L✓ �-� . Uf S vdl Trn c - Received By: Date: / �q Issued By: %(� 0` �i1Lu�� Date: 7 3 � I MUNICIPALITY OF /ANCHORAGE U:C Community Development Department - Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 020-271-04 Property owner(s) Michael & Nicole Besecker Day phone 330-0416 Mailing address 2808 Iris Drive, Apartment 1 Anchorage, AK 99517 Site address NHN Potter Heights Drive Anchorage, AK Legal description (Sub'd., Block & Lot) Potter Creek, Tract 1 Legal description (Township, Range & Section) Lot Size 3,267,000 Sq. Ft. Number of Bedrooms Three (3) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ® Initial © Single Family (SF) ❑X (w/wo ADU) Septic Tank 19Upgrade ElDuplex (D) ❑ Holding Tank ElRenewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: SPO -00 Waiver Fees: I Date of Payment: -7/25 1201 Date of Payment: Receipt Number: 0(-01315D Receipt Number: Permit No. � P113aa Waiver No. Permit App_:; -:-.—.mac: 1 PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) July 25, 2019 MOA Development Services Department On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Potter Creek, Tract 1 – NHN Potter Heights Drive Septic System Design Dear On-Site Services Engineer: The owner of the subject lot intends to construct a cabin on the property with the possible construction of a second cabin in the future. We are requesting a permit be issued to construct a well and septic system on the property. The absorption trench will be oversized to accommodate future construction. The attached site plan identifies the location of the home and the proposed well and septic system. No conflicts exist between this proposed system and any other well or septic system on this lot or adjacent lots. The ground surface on the lot slopes to the southwest at 20% in the area of the proposed trench. There are slopes greater than 25% within 50 feet down slope of the trench, but the absorption trench design meets the steep slope criteria of the Municipal Ordinance and no waiver is required. Ground surface contours are shown on the site plan indicating the grade and direction of flow. Storm water drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. The new system will be a minimum of 100’ from all wells and surface water, 10’ from any water service and more than 5’ away from the septic tank. Please refer to the attached test hole log and plan and profile sheets for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Michael E. Anderson, PE 7-25-19 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191322, Rebecca Carroll, 07/31/19 1 3 8 0 1 3 7 0 1 3 6 0 1 3 5 0 200100 0 FEET 1"=100' NOTE: NO SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND POTTER CREEK, TRACT 1 7/25/19 33' ROADWAY EASEMENT TH2 TH1 PROPOSED WELL 1,000 GALLON SEPTIC TANK w/20' MANWAY ALTERNATE SITE: CATEGORY III SYSTEM w/20' LONG x 5' WIDE x 4' EFFECTIVE DEPTH TRENCH. APP RATE 4 GPD/SF FUTURE DEVELOPMENT 94' LONG x 5' WIDE x 4' EFFECTIVE DEPTH ABSORPTION TRENCH. OVERSIZE FOR FUTURE DEVELOPMENT. THREE BEDROOM CABIN CO CO 2CO FCO MH SV MT MT Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191322, Rebecca Carroll, 07/31/19 POTTER CREEK, TRACT 1 DESIGN FACTORS: SYSTEM REQUIREMENTS: 750 GPD PEAK FLOW PERK RATE: 6-15 MIN/IN APPLICATION RATE: .8 GPD/SF 5' WIDE TRENCH SYSTEM 1,000-GALLON SEPTIC TANK TRENCH OVERSIZED FOR FUTURE DEVELOPMENT TYPICAL TRENCH SECTION (NO SCALE) 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 5' 6" 6" 3' 4' NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY BOTTOM OF TRENCH: 7.5' BELOW GRADE FLOW LINE ELEVATION: 3.5' BELOW GRADE TOP OF TRENCH: .5' ABOVE GRADE 750 GPD / .8 GPD/SF /5' WIDE * .5 RED. FACTOR = 93.75 LF TRENCH REQUIRED (94 LF SPECIFIED) 7/25/19 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191322, Rebecca Carroll, 07/31/19 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TH1 - EAST SLOPE SLOPE SITE PLAN See Site Plan DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) POTTER CREEK TRACT 1 6/20/19 L. TIDWELL DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH OF WATER AFTER MONITORING: IF YES @ WHAT DEPTH? NO NA NA 7.7 6 4 5 020-271-04 CLIENT 9:45 6/24 1 2 3 4 5 6 30 30 30 0 3 13 16 0 3 14 16 10:15 10:18 10:48 10:49 11:19 OB SANDY SILTY GRAVEL 6/28/19 Professional Engineers Stamp: 7/25/19 3 13 16 0 3 13 16 3 13 16 3 14 16 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191322, Rebecca Carroll, 07/31/19 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TH2 - WEST SLOPE SLOPE SITE PLAN See Site Plan DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) POTTER CREEK TRACT 1 6/20/19 L. TIDWELL DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH OF WATER AFTER MONITORING: IF YES @ WHAT DEPTH? NO None 5.3 6 4 5 020-271-04 CLIENT 9:32-9:42 6/24 1 2 3 4 5 6 10 0 - 1 7 8" 9:43 - 9:53 9:56 - 10:06 10:08 - 10:18 10:20 - 10:30 10:33 - 10:43 OB SANDY SILTY GRAVEL GM 6/28/19 Professional Engineers Stamp: 7/25/19 1 7 8" 10 41 - 43 7 8" 1 7 8" 10 0 - 1 7 8" 1 7 8" 10 0 - 1 7 8" 1 7 8" 10 0 - 1 7 8" 1 7 8" 10 0 - 1 7 8" 1 7 8" Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191322, Rebecca Carroll, 07/31/19 Carroll, Rebecca M. From: Michael Ian Besecker <mibesecker@yahoo.com> Sent: Wednesday, July 31, 2019 3:08 PM To: Carroll, Rebecca M. Subject: Reply from septic pumper Hi Becca, Here is the updated info from Mike at One stop pumping, he said no problem and to call if questions. Thanks, Michael (Lots of Michael's involved, haha) On Wed, Jul 31, 2019 at 2:58 PM, Michael Brown <mike@onestoppumping.com> wrote: Michael, Yes, we are able to pump 700', we will just have to use a larger pump inline. Good luck with your permit. Michael On Wed, Jul 31, 2019 at 2:12 PM, Michael Ian Besecker <mibesecker@yahoo.com> wrote: I Hi Mike, I sent your email over to the municipality and they would like you to change the number to 700ft. If you are able to pump that distance could you please reply with that info? Thank you! -Michael Sent from Yahoo Mail on Android On Wed, Jul 31, 2019 at 12:39 PM, Michael Brown <mike@onestoppumping. com> wrote: Michael, We can service your septic. A 400' run is very long so I will utilize a 3" pump inline from the tank to assist the truck so the job can go at a more normal pace and save the wear on the pump truck. Good luck on the build and lets us know when you would like to be serviced. Michael 1