NORTH WOODS BLK 4 LT 8
Municipality of Anchorage Community Development Department Page 1 of 3 On -Site Water & Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907)343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP191487 PID Number: 051-731-13 ❑ New ■ Upgrade Name: MATHEA DOYLE ABSORPTION FIELD ❑ Deep Trench ❑ Shallow Trench ❑ Bed ound Address: 22433 MCMANUS DRIVE, CHUGIAK, AK 99567 ❑ Other Phone: No. of Bedrooms: Sail Rating: Total Depth from origins de: 907-268-1465 4 (HOUSE IS ONLY 3) GPD/Sq. Ft. Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade: F Grave epth beneath pipe: Fl. Subdivision: Block: Lot: Fill added above original grade: Gravel length: NORTHWOODS 4 8 � F Fl. Township: - Range: - Section: - Gravel width: ! Fl. Beds Number of lines: Distance between lines: Ft. SEPARATIONDISTANCES Total absorp' area: Number of trenches: Dist. between trenches: To Septic Absorption Lift Holding Public/Private From Tank Field Station Tank Sewer Lines SD. FL Ft. Well 100'+ 25'+ TANK ■ Septic ❑ S.T.E.P. ❑Holding ❑ Other Manufacturer: INFILTRATOR SYSTEMS Capacity: 1530 Surface water 100'+ z z Gal. Lot Line 5'+ X x N/A Material: Number of compartments: w Ly PLASTIC 2 Foundation 10'+ - LIFT STATION Manufacturer. ca fry: Gal. Curtain Drain NONE KNOWN Remarks: 'Pump on" level al: "Pump otf" level at: High water alarm at: Pump Make S Model Electrical Inspections performed by: PIPE MATERIAL D3034 House to tank (FOR NEW) Tank to EXISTING drainffeld Installer D3034 NORTHERN EXCAVATION Drainfield EXISTING CO/MT (FOR NEW) Inspector GEG, Ltd. BENCH MARK (Assumed elevation) 100.00 Ft. Inspection Location and Description: Dates: 1st 11/26/2019 2nd - 3rd - 4th BOTTOM OF SIDING BY FCO ENGINEER'S SEAL Community Development Department Approval ������� � �`�� F o♦ �P, . ............i Conditional approval: Date: * ;'� #i : � —...... ......... .... {.. ......... .. . 0 y Garne s ;�AV ♦ :. CE -79 .� AV .� Approved: Date: lLICENSE ��� ES`;�:���• #AECC884 Inspection Report _1-1-12.doc PERMIT NUMBER: RECORD DRAWING I N G PARCEL ID NUMBER: OSP191487 051-731-13 I A B FCO 25.3 20.0 MH1 39.3 17.7 STI 42.9 25.2 DBL1 39.4 26.3 DBL2 38.4 26.2 PV 35.7 29.8 NORTHWOODS; BLOCK 4, LOT 6 -L----------- I I NOTE: OLD 1300 GALLON HDPE SEPTIC TANK WAS Q DECOMMISSIONED PER UPC I Qi PER THE CONTRACTOR. OI Qry I C� I EXISITNG PUMP VAULT (PV) FOR I.D.S.F.— WI , W I I NORTHWOODS;BLOCK4,LOT7 t dg NORTHWOODS; BLOCK 4, LOT 5 EXISTING INTERMITTENT DOSING SAND FILTER (I.D.S.F.) DRAINFIELD INSTALLED DOUBLE CLEANOUTS (DBL1 & DBL2) 11--ol 0 EXISTING 3 BEDROOM HOUSE NORTHWOODS;BLOCK 4,LOT 4 —NEW IM -1530 INFILTRATOR TANK (TWO-COMPARTMENT) NORTHWOODS; BLOCK 4, LOT 9 / ASSUMED LOCATION OF WATERLINE N / w- / > SCALE: / x / 1" = 40' \ 15' UTILITY EASEMENT ---------------------------------I-------------- ------------------------------ McMANUS DRIVE GARNESS ENGINEERING GROUP, Ltd ENGINEERING SALES CONSULTING 3701 E. TUDOR ROAD, SUITE 101 - ANCHORAGE, AK 99507 - PHONE (907) 337-6179 - FAX (907) 338-3246 - WEBSITE: w .gamessengineering.mm PREPARED FOR: PHONE NUMBER: PAGE NUMBER: MATHEA-DOYLE 907-268-1465 2 OF 3 PROJECT/LEGAL DESCRIPTION: DRAWN BY: NORTHWOODS S/D; BLOCK 4, LOT 8 J.L.M. TYPE OF WORK: DATE: � RECORD DRAWING OF SEPTIC TANK UPGRADE 12/3/2019 PERMIT NUMBER: PARCEL ID NUMBER: OSP191487 RECORD DRAWING 051-731-13 GARNESS ENGINEERING GROUP, ENGINEERING < SALES CONSULTING 3701 E. TUDOR ROAD, SUITE 101 'ANCHORAGE, AK 99507 -PHONE (907) 337.6179 -FAX (907) 338-3246' WEBSITE: w .gamessengine PREPARED FOR: PHONE NUMBER: PAGE NUMBER: MATHEA DOYLE 907-268-1465 3 OF 3 PROJECT/LEGAL DESCRIPTION: DRAWN BY: NORTHWOODS S/D; BLOCK 4, LOT 8 J.L.M. TYPE OF WORK: DATE: �,, RECORD DRAWING OF SEPTIC TANK UPGRADE 12/3/2019 -E@ .87 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP191487 Work Type: SepticTank Upgrade Tax Code Number: 05173113000 Site Legal Address: NORTH WOODS BLK 4 LT 8 G:1459 Site Mailing Address: 22433 MC MANUS DR, Chugiak Owner: DOYLE MATHEA A Design Engineer: GARNESS ENGINEERING GROUP LTD This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: tl/2(0/19 ,��1leilj �c =fit Department 10/28/2020 20000 ❑ Disposal Field 2 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezirig Received By: J Issued By: 1 (mac Date: ! cr I Date: 4 MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Fax: 907- 343-7997 On -Site Water & Wastewater Program On -Site Sewer/Well Permit Application For A Single Family Dwelling Parcel I.D. 051-731-13 Property owner(s) MATHEA DOYLE Day phone 907-268-1465 Mailing address 22433 MCMANUS DRIVE *CHUGIAK, AK 99567 Site address 22433 MCMANUS DRIVE 'CHUGIAK, AK 99567 Legal description (Sub'd, Block & Lot) NORTHWOO Legal description (Township, Section & Range) BLOCK 4, LOT 8 Lot Size Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: (®all that apply) Initial ❑ Absorption Field ❑ Upgrade Septic Tank Renewal ❑ ❑ Holding Tank Privy ❑ Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE/ WAIVER REQUEST FOR: N/A TYPE OF DEWELLING: Single Family (SF) (w/wo ADU) Duplex (D) ❑ Multiple Dwellings ❑ (SF and/or D) Distance: _- I I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: 0149 (4 6 Permit No. A5 0 `q I C191 Waiver Fees: Date of Payment: Receipt Number: Waiver No. (Rev. 01/11) GARNESS ENGINEERING GROUP, Ltd — -I ENGINEERING o SALES o CONSULTING:- -- - — November 1, 2019 (Revised ) Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Ref: Northwoods; Block 4, Lot 8 — Septic Tank Design Upgrade To whom it may concern: The existing 3 -bedroom house is served by public water and a private septic system. During the process of requesting a COSA, it was documented that the liquid level in the septic tank was five (5) inches out of level between the two compartments. This is likely due to the tank being installed in a high groundwater area and while being pumped the tank was damaged. We are proposing to decommission the existing 1300 -gallon HDPE tank and install an IM -1530 Infiltrator tank (two-compartment). The existing pump vault will remain in place. We are unaware of any adverse impacts this installation will have on adjacent wells or septic systems. Alf you have any questions, please contact us at 337-6179. Thank you for your assists e. Sin�Vrely Jeffreytj 6; ss, E., M.S. Presi 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com 10x15 Anchor Esmt a El NORTH WOODS; NORTHWOODS; C3 BLOCK 4, BLOCK 4, LOT 1 LOT 14 NORTHWOODS; NORTHWOODS; NORTHWOODS; NORTHWOODS; NORTHWOODS; BLOCK 4, BLOCK 4, BLOCK 4, BLOCK 4, BLOCK 4, LOT 6 LOT 5 LOT 4 LOT 3 LOT 2 NORTHWOODS; NORTHWOODS; NORTHWOODS; NORTHWOODS; \4, BLOCK 4, BLOCK 4, BLOCK 4, BLOCK 4, LOT 7 LOT 9 LOT 10 LOT 11 NO 15' util Esmt NORTHWOODS;\ BLOCKOCK3, RTHWOODS; NORTHWOODS; NORTHWOODS; N THWOODS; NORTHWOODS; NORTHWOODS; LOT 7 BLOCK 3, BLOCK 3, BLOCK3, BLOCK 3, BLOCK 3, LOT1 LOT LOT LOT f SCALE: 1"=100' BLOCK 3, I NOR42 THWOODS; 3, T 41 I NORTHWOODS; 3, I NORT 40 THWOODS; DS; I NORTHWOODS; I NORTHWOODS; 3, I NORT 37 THWOODS; GARNESS ENGINEERING GROUP, Ltd -- - -- -- —= ENGINEERING -SALES CONSULTING -_-_-- - -� 3701 E. TUDOR ROAD, SUITE 101 ' ANCHORAGE, AK 99507' PHONE (907) 337.6179' FAX (907) 338-3246' WEBSITE: www.gamessengineering.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: MATHEA DOYLE 907-268-1465 1 OF 2 PROJECT/LEGAL DESCRIPTION: DRAWN BY: NORHTWOODS; BLOCK 4, LOT 8 PNB TYPE OF WORK: DATE: �, SITE PLAN 10/22/19 OF 4L �.,.....7...7.�................ 7..�. .� s�%;. J re)j A: Garness _ i� c')_%. / 6E 7953 AV w LICENSE 1 1\\\S\�__S••♦ #AECC884 ALL ADJACENT LOTS ARE SERVED BY PUBLIC WATER NORTHWOODS; BLOCK 4, LOT 6 EXISTING 1300 GALLON HDPE SEPTIC TANK TO BE DECOMMISSIONED PER UPC --�_ GEG, Ltd. HAS AN 8 PAGE SPECIFICATION LETTER CONTRACTOR TO ENSURE THAT THE THAT PERTAINS TO THIS DESIGN. BY PROCEEDING PROPOSED TANK MEETS 51+ FORWARD WITH THIS INSTALLATION, THE SEPARATION FROM ANY PORTION OF ENGINEER, WELL DRILLER, CONTRACTOR AND DECK OR STAIRS THAT IS 30" OR PROPERTY OWNER AGREE THAT THEY HAVE HIGHER AND 10'+ FROM HOME READ THESE SPECIFICATIONS AND AGREE TO FOUNDATION. ACCEPT THE TERMS AND CONDITIONS OUTLINED. NORTHWOODS; BLOCK 4, LOT 5 EXISTING DRAINFIELD DBL CO'S NORTHWOODS; BLOCK 4, LOT 7 �w 4 EXISTING 3 BEDROOM HOUSE ASSUMED LOCATION = '� OF WATERLINE / 10X15 / Anchor Esmt NORTHWOODS; BLOCK 4, LOT 4 —PROPOSED IM -1530 INFILTRATOR TANK (TWO-COMPARTMENT) NORTHWOODS; BLOCK 4, LOT 9 1"=40' ----------------------------- t—____________ ——__}—_____—_____________________ MCMANUS DR .•,�� OF i !s. GARNESS ENGINEERING GROUP, Ltd ; ...... 9...... ................�— ENGINEERING - SALES CONSULTING - - 3701 E. TUDOR ROAD, SUITE 101 ' ANCHORAGE, AK 99507PHONE (907) 337-6179' FAX (907) 338-3246' WEBSITE: v .gamessengineering.com 0 .... .• •, ..• •••••........... IL PREPARED FOR: PHONE NUMBER: PAGE NUMBER: (n • J�erey ... Ga Hess .:• ■ MATHEA DOYLE 907-268-1465 2 of 2 �j� C 7.ii 7 n •..����� PROJECT/LEGAL DESCRIPTION: DRAWN BY: °♦ (��• •.. I� �:�NORTHWOODS; BLOCK 4, LOT 8 PNB p ��P�•� TYPE OF WORK: DATE: LICEN,�",OFESS1 �•• SEPTIC TANK UPGRADE DESIGN REVISED 11/1/19 #AECC884 ���"� MUNICIPALITY OF ANCHORAGE WATER & WASTEWATER UTILITY 3000 ARCTIC BLVD. PHONE: (907)564-2762 BLOCK/LOT/TRACT BLK 4 LT 8 SUBDIVISION NORTH WOODS WATER CONNECT PERMIT C7 1 99-0834 DATE OF APPLICATION 10/28/1999 SCHEDULED COMPLETION DATE 12/31/1999 [X SINGLE FAMILY MULTI -DWELLING No. APTS COMMERCIAL TAX CODE 5173113 GRID ERNW14 AS -BUILT STREET ADDRESS tp, G vq�. fRNU S OWNER NORTHWOODS INC PHONE MAIL ADDRESS 3111 C ST STE 555 ANCHORAGE, AK 99503 CONTRACTOR TWEED EXCAVATING ASSESSMENTS f 1 Repair Existing Service I Main Line Extension IXI On Property Only �_ City Tap IXC Have Been Levied Hydrant Only 50' or Longer ❑ To Be Levied () Main Tap - To Property Line Only Comments: Main Tap & On Property Connect Row No. Disconnect R & R - Main Tap Only ;Owner [Staff CONNECT SIZE 1" ISSUED pcousins INSPECTION FEE $ 103.00 IV PAID CASH PERMIT FEE $ 45.20 I. J CHECK # $ 0.00 MOTHER DEPOSIT $ 0.00 INSPECTED BY REIMBURSABLE TOTAL $ 148.20 WOJONOWSKI NUMBER I DATE // / / / 79 REMARKS PERMITTEE (Please Print) -1,4 j - PHONE `7`,' _'3 MAIL MAIL ADDRESS SIGNATURE pub POST IN A CONSPICUOUS PLACE AT THE JOB SITE AWWU INSPECTOR Original W I- a� d� Zo pk�.Z itJ J J Q tJ H W ]G tt! } m Z 0 h Q Q 0 J W Z J W V w cn G Z Q X O LU m F -- w LU H ati Municipality of Anchorage Page of DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report - -2 *31-1-3 S 990-3 9 © G , 1--'-2 Permit Number: PID Number: Name: lGeo1^ Li yrro'��, , � Wastewater System: N New ❑ Upgrade Address, :31116 5ty,-e4 5"j-fe 555 A, 89.503 ABSORPTION FIELD Phone: No. of Bedrooms: `-ITj / El Deep Trench O Shallow Trench O Bed XMound O Other LEGAL DESCRIPTION Soil Rating: ':�O Total Depth from original grade: GPD/Sq. Ft. I Lot: Block:L/�I Subdivision: -6 woods Depth to pipe bottom from original grade: Gravel depth beneathpipe Q-06rgvr2l / .IUa!' -+ J0')15' Ft. O-D5 Ft. Township: Range: Section: Fill added above original grade: Gravel length: % jj� �i' ♦ T Ft. �K Ft. WELL: ❑ New ❑ Upgrade Gravel width: 0 Numberoflines: 4 Distance between lines: 005 Ft. Fl. Classification (Private,, A,B9,C): Total D PLA 6116 Cased To: Total absorption area. �V Pipe material: lit/ J e/- Ft. Ft. (/ SQ. Ft. Rs Al .05034j,/3 V C S'cti 4 Driller: Date Drilled: Static Water Level: Installer: JJ // L/ 7'Wc��G( Date installed: CI �—� % — Ft. GXCA VA r r e ` Yield:Pump Set at: I Casing Height Above Ground: TANK GPM Ft. Ft. SEPARATION DISTANCES Useptic ❑Holding 0S.T.E.P. To Septic Absorption Lift Holding Public/Private Manufacturer: bI Capacity in gallons: i p y g 3 OQ From Tank Field Station Tank Sewer Lines ('� L e% I to s le-• j it Well- Material: P iele Number of Compartments: oket& WateSurface r )Q "•� )00 100`-1- LIFT STATION Lot Line �- o + O Size + ipallons: IV Manufacturer: i�U/t2Tff CAST , Off °--.F TV TN Foundation l L 3 4S / \ "Pump on" level at: I�� "Pump off level at::C ,l High water armat, Curtain v Pump Make & Model Electrical Inspectioonns`/p7/erfoormed by: Drain Oyj f� ej p ✓1 6146-re; )OCR Remarks: I YJ r R I-L rrA... T D O S BENCH MARK / Li� P, l Qo7'T0;•' 6 51 ) W LT/� ' Location and Description: o of OVIU IT Of Assumed Elevation: 100 ENGIN FBRrS',�FAL 7Sr r a S & S ENGINEERING 17034 Eagle River Loop Rad o, 1119s •; r� �� t 7 ' ` Inspections performed by: Earle Ftiveri Alaska995. Dat�'s:1st �o �a "•. • ., f 2nd �,na1 11-1`g9¢� V A ROBERT C. COwAN �t,Q 4i; ti CE-8801 Department. of Health and Human Services approval ��;-F;•., :� Reviewed by: 92=� Grp and approved Date: 72-013 (Rev. 9/91) MOA 25 PERMIT NO. SW990396 PAGE 2 OF 3 Municipality of Anchora�ge DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 ® Telephone: 343-4744 On—Site Wastewater Disposal System and/or Well Inspection Report LEGAL LOT 8, BLOCK 4, NORTHWOODS S P.I.D. NO. 051-731-13 LCAT 6 LOT 5 LOT 4 NEW BED MT2 MTi 1-FV4 TH#2 CO 1300 GALLON POLYETHYLENE MH �rX o T2 SEPTIC TANK • Ti TH#1 TBM A FCO B LOT 7 EXISTING LOT 9 FOUNDATION 0 L 10X15 ANCHOR EASEMENT I I E,6ttZtEEtiTA�� t VM 15' UTILITY _ EASEMENT _ 'tN �d /� /� /� T T C n .... ...........�... ,-...,........ a ..�� 7t ROBERT C. COWAN �Q ���s CE 8801 •� - SCALE 1 " = 40' ��4y PERMIT NO. SW990396 PAGE 3 OF 3 MunicipaUt of Anchora e DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Ataska 99519-6650 • Tennt^^e��hone: 343-4744 ©N—SITS WASTEWATER DISPOSAL SYSTEM AND/OR WALL INSPECTON REPORT LEGAL LOT 8, BLOCK 4, NORTH WOODS P.I.D. NO. 051-731-13 FINAL GRADE MT1=99.1' MT1 MT2 MT2=99.9' �- INSULATION '''�[ORIGINAL GRADE mm INSULATION 95.1' STI —FINAL GRADE ST2 C01 to 14 TOP 2' INSULATED EFFLUENT OUTLET -poll, 9 NEW 1300 GAL. t3s'r� POLY. TANK �— •m ® y. GROUNDWATER AT 'qf.O 87.0' B.O.H. N. T. S. �Vo Rising Son Electric 907 688 6777 05/10/00 03:19P P.001 April 5, 2000 Rising Son Electric • 1•: Chugiak AK, 99567 (907) 688-6777 Re: Lift Station at Lot 8 Block 4 Northwoods To Whom It May Concern: This letter is to certify that Rising Son Electric, Electrical Administrator license number 1284, Contractor license number 25396 has successfully completed the electrical connections in accordance with the N.E.C. for the lift station at the above referenced property. Should you have any questions, please do not hesitate to call me. Thank you. Sincere Kevin S. Hornbuckle Owner/Administrator K5H/cmh MAY -08-2000 11:06 S&S ENGINEERING OIL*PROPERTY OWNER FOR THE MALNTENANCE OF AN C ON-SITE ! . A SYSTEM 907 694 1211 P.02i02 This agreement, datedS ©� 2000 , is made between ttte Municipality of Anchorage Department alth and Human Services (DHHS) and the property owner(s) of: Lot 8, Block 4, Northwoods Subdivision This agreement is made for the purpose of maintaining an on-site wastewater disposal system on the subject property. The property owners agree to the following: Submit to the Municipality of Anchorage, on an annual basis, an inspection and operation statement from a registered professional engineer. This inspection and operation statement shall verify that the engineer has inspected all effluent and air pumps, timers, and alarms, and that any deficiencies have been repaired and that the system is functioning as designed. (Signature) (Printed Name) (Notarize Dere) (Signature) (Printed Name) TOTAL. P.02 S _ _ MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On -Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Permit Number: SW990396 Legal Description: NORTH WOODS BLK 4 LT 8 Design Engineer: 0003 S & S Engineering Owner Name: George Wilmoth Owner Address: 3111 C Street, Suite 555 Anhorage , AK 99503 - Pn. IC -"X-)- 9� Date Issued: Oct 21, 1999 Expiration Date: Oct 20, 2000 Parcel ID: 051-731-13 Site Address: Lot Size: 20000 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy All construction must be in accordance with: 1. The attached approved design. ❑ Private Well ❑ Water Storage 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: A Date: � �� 7 Date: s&S� iln-M. lnG May)4, 1999 ROBERT C. COWAN, P.E. CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 HEALTH AUTHORITY APPROVALS MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, AK. 99519 SEWER&WATER MAIN EXTENSIONS REFERENCE: Lot 8, Block 4, North Woods Subdivison SEWERS WATER INSPECTION Request you issue a permit to install a Biocycle System to serve the four bedroom dwelling on the referenced property. ENGINEERING STUDIES Two test holes were excavated and percolation tests were performed. The approximate AND REPORTS location of the test holes are located on the attached site plan. At the time of excavation 6/12/98 water was found in the first test hole at four feet. The WELL INSPECTION second test hole was dry. After seven days of ground water monitoring, water was SFLOW TEST found at 3.5 feet in the first test hole, and in the second test hole at 4.5 feet. We do not anticipate any adverse effects on neighboring wells, septic systems, reserve SITE PLANS areas or drainage patterns by the installation of the proposed septic system. The construction of this system will not prevent any future development on any of the adjacent properties. ROAD DESIGN If you require additional information, please contact us. Sincerely, SOIL TEST PERCOLATION Robert C. Cowan, P.E. TEST RCC/j h Enclosure STRUCTURALS MECHANICAL INSPECTIONS ON SITE WASTEWATER DISPOSALSYSTEM DESIGN 17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577 F-1 " = 40' 1 SITE 11 PLAN oar tJ xC-� ,ti T CI0 C=I moo H z x N � o Zw CO Ca a z 11 on's x� .uv =.2m 6FU, Zm�K TOD 1~nOm� �m rz I I I I I I I �I I ---------------------- JS ---- - I -"I------------ 1 I L 0� 1,VMMNG =w X Iml __- ------ 1 O a) (A L� I 1 I I f'l Orm tA � j z�0� j �7 H I r z 1 K O I I O I I � I mQ 1 I L --J C� I I O 0 I 0 < U)'-, -0 I� rCA 0Q �v I 1V�y VROpo D `v`D`vT`vt�Nv�-v�v`v it D •0 70> v rel -� 1 m 1 off U1 O O 0 O C m m mo Q c a < m in C I m U) D ),VM3AINC) N � I I— n a O aH � I I I I m Q ca co ZO a r -4 c p 1 � O ;0m O o - Z I 1 cJnOc)- r m I 1 I I f'l Orm tA � j z�0� 1 I I I I I I I I I I 1 I I H �-�p C-) M 1 I I i I I I i Cp 9 H N I I I mQ 1 I L --J C� i i i I i I i i I 1 I I -o o n p 1 � O ;0m O o - Z ay cJnOc)- > ONO ; Ut � f'l Orm tA o z�0� \O N P II H �-�p C-) M Cp 9 H �0 �rn mQ m wOo C� N O 0 �� 0 < U)'-, -0 I� rCA 0Q . • m T1 *1 D -1 it D •0 70> v rel CTI I N -p U1 O O M O Q < m � (.0 Q U) D v�1 z 0 I— n a O aH 0 W A z 11„VI/ \SII -o o n co W O ;0m O o - Z � 0 Z D o-4 yr Ajj = d0 t� rn nC.)r�i o D y A a„ „• FJ ?� a✓ O � Cp 9 H n 5 o o n m Z CTI I N Ln � (.0 O p �TnJ v�1 I— n a O aH O 4-1-- -o o n �S •,4+=' v t� ' . 1� O ;0m O o - Z �sr J; .+• 0 Z D o-4 yr Ajj Zb �• rn a p r m f4 r"n. rn nC.)r�i ,�=,• �.. D y A a„ „• FJ ?� a✓ CA rl t: N.T.S. BED DETAIL m V DO *7=ry X Z m m MM m�D <M O t0- A m to QO ,ow, V t4 .0 < N �. Cid � ® ® ® ® ® 0 ' O � f I Z� t-4 < N CO m I V I td U) z I mt--" < C m nm ° O m w I z -Tl o oa D "' cnI I N Q C O Tl C J I C0 N i \OOM-0 d �\ ' c0 r r- ;u0 II = I I N M f'l r"� 0 Q m O D W CA D O oD. zcn I I N m �D o> LA p �2 3 3 2� zo Z , V 11 ,> Ln OrD�^p0 o N m p W z (0ni� ® o 0O�ODp �� P D D 11 N O Q O z Q YZ' ; rn m (;��iqqt � fl N OC)O � z a N.T.S. PROFILE N DETAIL I i V �Dw 0 i59 Er SCALE l6a &IZ Z jtf / o O X m z1hmmC �<r O0 o C VO XZ �mNA V, QO mO O 0 C, 0 _tow w 1 10 V L.p ly J Z V O N r O MMy O -1 O }. r 1W -III tti A i5a 165 N i59 Er D l6a &IZ jtf / o O O mer Y59 RrO 9 N O 9 m 10 C 1m Cz N O^ 1'�7 C z MM HO N 0 'd t^ � �o r C zz n C7 H > y o o s b d z N y 0 O 2 N o p C z z � t jtf / o O N.T.S. BIOCYCLE DETAIL SCALE �v DOm r 00 piD- I l 09 w cn V' m 7c m A A D C (b- NWwOp l tov0 b v oN i v r O y A = co Z nv D O nn� ov ism iCo Z A iA tri CQ / m r o y Cn� M —v Fi r[J W z p `i0 to z z Owm D N y nmoc v MOW ! � C7 _ uz C' D °ov_ NZO 6-06' 2.6' Z �' m ( ) (800mm) m 3 a 185Dmm �.{ Z [D O l —i N X o Vz (/) [ U� m WJ ^ w�l 3dl 3N m �q 3 V 3 3 pp ~ `J 0 P Z 0 Tf cn 3 3 J i7 3 CJi n �>' rr• m '' • L r �t z z M •-1 � H f � mco Y � • �)'� 7Cx �x xJx /: i`: C7 i ii D .50 FR U4� Municipality of Anchorage y ' -�'°s� ✓'�, DEPARTMENT OF HEALTH & HUMAN SERVICES Jto. 825 "L" Street, Anchorage, Alaska 99502-0650 1' SOILS LOG - PERCOLATION TEST P� ? ROBERT C. COWAN PERFORMED FOR: ✓(glom 1�1-t(� DATE PERFORMED: \.b LEGAL DESCRIPTION: ✓�C� Township, Range, Section: E T , flU0$ SLOPE SITE PLAN 1 2- 3- 4- 4 5 5- 6 7 8- 9- 9 10- Q4 . to •L� Net Drop Z z- 2v ✓inns C,�` " P > 10 WAS GROUND WATER ENCOUNTERED? 11 S IF YES, AT WHAT t L DEPTH? �p O 12 P 13 Depth to Water After Monitoring? '� +6 Date: 14- 15- 16- 17- 18- 19 - Reading Date Gross Time Net Time Depth to Water Net Drop Z z- 2v ✓inns C,�` " 20 PERCOLATION RATE' G (minutes/inch) PERC HOLE DIAMETER la � TEST RUN BETWEEN _4 + _ FT AND 2"15r FT COMMENTS J Ot a CIV6711MLLKINU PERFORMED BY: 178034 EnglA Riyg-j! I gonrn?4io hi.. 9ft4 � ✓~"' CERTIFY THAT HIS TEST WAS PERFORMED IN ACCORDANCE WITHEAL� S�ATE'AN'ISStvfUNIR RL GUIDELINES IN EFFECT ON THIS DATE. DATE: [ 72-008 (Rev. 4/85) U4-� Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST ,I �c S ROBERT C. COWAN s �� '0 . RRn i S, PERFORMED FOR: Lt► `©k i— DATE PERFORMS �; Z3 .IZ ',`, 'j `• r LEGAL DESCRIPTION:�—O•C `-t 1.1 Pmt 1•k Township, Range, Section: COMMENTS NG P, 5, IF YES, AT WHAT DEPTH? 7t Depth to Water Att, r Monitoring? BION mmom MEMO ■■N■ ■■E. ■ESE MMIMEO MEN NOME Jo _l S L N O P E Date: SITE PLAN Reading Date Gross Time Net Time 0/I P (F Per—, b G�r/4-sI 2 - 3 �. 6 C'10 4 5 6 7 s a* 9 10- 11 12- 21314151617181920 17 13- 14- 15- 16- 17- 18- 19- 20 COMMENTS NG P, 5, IF YES, AT WHAT DEPTH? 7t Depth to Water Att, r Monitoring? BION mmom MEMO ■■N■ ■■E. ■ESE MMIMEO MEN NOME Jo _l S L N O P E Date: SITE PLAN Reading Date Gross Time Net Time Depth to Water Net Drop Per—, b 17 PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER �+* TEST RUN BETWEEN 7� FT AND ;j FT 17034 Eagle River Loop Road No..2 PERFORMED BY: I CERTIFY THAT THIS TEST WAS PERFORMED W Eagle River, Alaska 99577 ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) PROPERTY OWNER AGREEMENT ® FOR THE MAINTENANCE OF AN ON-SITE WASTEWATER DISPOSAL SYSTEM This agreement, dated 199, is made between the Municipality of Anchorage Department of Health and Human Services (DHHS) and the property owner(s) of: G 0&-41- 4200 This agreement is made for the purpose of maintaining an on-site wastewater disposal system on the subject property. The property owners agree to the following: Allow the Municipality of Anchorage the perpetual right of entry to the property during normal working hours, to allow for effluent sampling or evaluating the general state of repair or function of the system. Submit to the Municipality of Anchorage, on an annual basis, an inspection and operation statement from a registered professional engineer. This inspection and operation statement shall verify that the engineer has inspected all effluent and air pumps, timers, and alart , and that any deficiencies have been repaired and that the system is fwlctio► ' tg as c}( --signed. Zignature) (Signature) (Printed Name) (Printed Name) State of Alaska L.NOTARY PUBLJ20O3 (Notarize Here) ndra K. Hemphmission expires Jan. 2 �E ®Municipality ®f Anchorage _4� �� RR I UC,3�, it y1` On -Site Water and Wastewater Program (907) 343-7904 s A E r Certificate of On -Site Systems Approval Parcel I.D. 051-731-13 1. GENERAL INFORMATION: Complete legal description _ Northwoods; Block 4, Lot 8 Expiration Date: 1 2-41 —2. ©2 O Location (site address) 22433 McManus Drive *Chugiak, AK 99567 Current Property owner(s) Mathea Doyle Day phone 268-1465 Mailing address Real Estate Agent 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ® Public Sewer ❑ WaiverNariance request for. Distance: Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 55-6 Date of Payment r:LW 14 Receipt Number 6 1273 (7 COSA#Q5C.1 q 15g/ Date: Waiver Fee $ _ Date of Payment Receipt Number, Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 11 Engineer's Printed Name: Jeffrey A. Garness Date: In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system Q00000O�� o "' �J in accordance with the guidelines and regulations established by the Municipality of Anchorage and ��..• Q industry practices. The reported results describe the condition of the system/s on the date/s of the identifiable evaluation. Separation distances were measured to readily features. Hidden defects or _ Aa I •• encroachments may exist that were not identified during the evaluation. The operational life of all wells ;: and septic systems depend upon a variety of variables, including but not limited to, soil conditions, rjJ • • • • • • • • • • • • groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and are outside the control of GEG. Satisfactorytest results do not guarantee future performance of the g p ....... J �frf ••, f r H. -or ess;' system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of VCE 7953 the well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the current systems fail to perform adequately in �4,P�q • •..... • �c°G the future. The content of this report is for the sole benefit of the person/party that retained GEG to rofes5', 0\ � O�O��oQoo perform the evaluation. Reliance upon the information provided in this report by any other person or party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE �System #1 Approved for bedrooms System #2 Approved for Disapproved Conditional approval for A bedrooms bedrooms, with the f ROC' ollo Z stipulations: G�co Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory COSA blue sheet 10-10-12.doc Nitrate Advisory, Arsenic Advisory Other 1 Legal Description: NORTHWOODS; BLOCK 4, LOT 8 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) n. Date of flow test for CO Static wateElpyetat beginning of test ft. B. TANK DATA Age of tank(s) New years Tank type/material "'d'mDn Measured operating fluid level in septic tank New ❑ Standpipes/foundation cleanout per record drawing Date of pumping New D. ABSORPTION FIELD DATA IDSF Which system tested (date installed) 10/29/99 ❑ ALL standpipes present per record drawing Total measured depth from grade *2.8+ ft (max) Measured depth to pipe invert from grade ft (min) ❑ N/A.- pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective OR Code -required soil cover over field **@MT ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Parcel ID: 051-731-13 Structure served by this system Well production at time of test pxtq-�' Water storage tank volume , _ -_ gallons Well disinfected f (form test? ❑ Yes ❑ No FE] Co ' bacteria is Negative itrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by _ Date of Sample C. LIFT STATION ❑ Required maintenance completed Age of lift station 20 years Lift station material FRP Comments: N/A Adequacy test date 1 0f711 Results Q Pass For 3 bedrooms Fluid depth prior to test 0 in Water added 450 gal New depth 0 in Elapsed time 0 min Final fluid depth u in Absorption rate 450+ gpd Any rejuvenation treatment (past 12 months) N/A *'367 If yes, enter date N/A Gallons introduced gallons Comments/Deficiencies: *AT MONITORING TUBE "FIELD IS INSULATED PER 1999 DESIGN. DATA IS FOR 2013 DRAINFIELD ONLY. ***PRE-SOAK REQUIRED = 360 FT2 X 0.25 FT X 0.4 X 7.48 GAUFT3 = 270 GALLONS PRE-SOAK AND TEST PERFORMED ON SAME DAY. COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) SepfiV-T*nQQft Station on Lot > 100' Q Yes Community Sewer Manhole/Cleanou _ ft If absorption field is under driveway comment below ❑ Yes if No ft if No Yes if No ft Neighboring Tank > 100' ✓❑ No AWWU WATER rivate r Septic Line > 25' ❑ Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No ❑� Holding Tank > 100' ❑ Yes if No ft Neighboring Absorption Fields > v Yes Animal Con t > 50' ❑ Yes if No ft ❑ Yes if No ft Manure/Animal Excreta Storage nity Sewer Main > 75' ❑ Yes if No ft ❑ Yes i ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑� Yes if No ft Surface Water > 100' Yes if No ft Property Line > 5' ❑� Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' 0 Yes if No ft Private Wells > 100'✓❑ Yes if No ft Water Main > 10' Q Yes if No ft Community Wells > 200'✓0 Yes if No ft Water Service Line > 10' Q Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Q Yes if No ft If absorption field is under driveway comment below Property Line > 10' 0 Yes if No ft Wells on Adjacent Lots: Water Main > 10' ✓❑ Yes if No ft Private Wells > 100' Q Yes if No ft Water Service Line > 10' ❑� Yes if No ft Community Wells > 200' Q Yes if No ft Surface Water > 100' v Yes if No ft F. ENGINEER'S COMMENTS 1-9Si�(JLa, L,r=v1 12-19 G. ENGINEER'S CERTIFICATION o � OF 4�"'%%% o � �S 4 I certify that 1 have determined through field inspections and review DO j� of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. �, , , , :, .. ?i ,f. • , . . . . . , COSA Checklist yellow sheet QO f r y A. am ss: CE— 951 aprofen i°°° o #AECC88� , ".fes e s���� Lift Station/Pump Vault Maintenance Log Owner s Street Address 224 -r S Septic Tank: -Sludge level inches -Pumping: require es no -Pumping completed es no Lift station: .Pump basket cleane es no -Effluent filter cleaned,_� no •Control floats cleaned es no -Proper float settings confirmed � e no -Operation satisfactory! es no �- Alarm System: -Dedicated electrical alarm circui e no -Audible and visual alarm inside dwellin es no .Alarm system operation satisfaRo-0 not satisfactory Manhole Riser -Ground water intrusion at riser to tank connection yeses .Ground water intrusion around pipe penetrations es o -Weep hole functional es no -Manhole lid: Function e no Insulate es no Properly Secure no Other rrN -All manufacturer required inspections and maintenance complete es no Comments: MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this Day of of 20 , by and between t� uof h6d t'1af7 n , herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as , 53 d 5C`` to C,/ located at (legal description) 2. Maintenance. Repairs and Alterations. (Owner is required to read, understand and initial each section) Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of OW IVERt By: J/Xr (signature) Date: 1�� i t CAA r i'' �hi n int name) STATE or ALASKA ) SS. THIRD JUDICIAL DISTRICT ) The foregoing instrument was acknowledged before me this day 11 day of 201rr "VI 3 NE1rf��i�. NOTARY PUBLIC 1:0R ALASKA �` QC`ys�.........oa'�'/`��' My Commission expires: MUNICIPALITY: (signature) i .yjAUBLIGo° I s`- O� d �?QjfC.0mo O.`l p• `✓ef6f11f'e11 X104 F; Date: Z Z r (print name) Title: (rev. 05/18/2018) Page 3 of3 (v Frontier Surveys, LLC Project No: 19-479 Ordered By: Kibe Lucas ti N90° 00' 00"W 100.00 Scale 1" = 30' S89' 54'49'W 100.26 PR N90' 00' 00"W 203.54 REC. S89' 54' 49"W 204.07 MEAS. SHED 0 N 3.7 11.8 21.1 i LOT 7 /i. 16.7 15' UTILITY EASEMENT L (St Date:11/27/2019 Plat: 79-245 1 Grid: N/A SHED 1.5 N ti LOT S90'00'00"E 100.00 CALC. S90' 00' 00"E 100.00 REC. • �S N C - - - - - — C McMANUS DRIVE - - - - - y Electric Meter/Outside Power 'Q� Telephone Pole O Metal Post 19.5 24.3 �y Gas Meter n Deck o- Fence 7e1. Pedestal `5; Septic ® Water Valve ne Mailbox Z2, Elec. Pedestal Q �S 4111 Found Rebar General Notes: 0 15 30 60 1. This document is created for the purpose of a single property transaction and is subject to Federal Copyright Laws. -2. Excepting for gross negligence; the liability for this survey shall not exceed the cost of preparing this survey: - — SCole iri Feet Lot 8, Block 4 This survey complies with the ASPLS Mortgage Location Standards. The survey represents visible improvements and O -Z'' (E . F .. <. 11 +11 Northwoods Subdivision .`. .tQ; •'' • a subsequent boundary survey responsibility of he Ownee r to determines he existence of any easements, covenants, or restriction which do no appear on the record plat. Under no circumstances 20,000 Sq. Ft. +/- '. '9 /� should this document be used for construction or for establishing a boundary or fence line. 49TH 22433 N McManus Dr. rn As-Built Survey of: 7 Story wood Frame House Q Frederic W. ner h'� N0, L.5,9946 �� !7✓lcrr I, Frederic Wagner, hereby certify that this Mortgage Inspection Survey was performed by me, or Mh Altached 3 Car Casga under my direct supervision on November 27th, 2019. - Jy yyr191 IDR* * ..... OFES;IONP� ?O Fronter Surveys, LLC 650 W!58 h Ave. Suite E Anchorage, Alaska 99518 0 �IER,. 907.460.1686 - info@frontiersurveys.com PROFESSIONAL SEAL S90'00'00"E 100.00 CALC. S90' 00' 00"E 100.00 REC. • �S N C - - - - - — C McMANUS DRIVE - - - - - y Electric Meter/Outside Power 'Q� Telephone Pole O Metal Post - �y Gas Meter n Deck o- Fence 7e1. Pedestal `5; Septic ® Water Valve ne Mailbox Z2, Elec. Pedestal 4111 Found Rebar General Notes: 0 15 30 60 1. This document is created for the purpose of a single property transaction and is subject to Federal Copyright Laws. -2. Excepting for gross negligence; the liability for this survey shall not exceed the cost of preparing this survey: - — SCole iri Feet 3. All measurements/setbacks are to the visual/apparent building footprint. 4. All dimensions to property lines are plustminus 0.1ft This survey complies with the ASPLS Mortgage Location Standards. The survey represents visible improvements and O -Z'' (E . F .. <. 11 +11 tions at the time of the survey, a boundary survey and subject to r accondcuracies that emay nt oreveal. es not IIs thet .`. .tQ; •'' • a subsequent boundary survey responsibility of he Ownee r to determines he existence of any easements, covenants, or restriction which do no appear on the record plat. Under no circumstances z Gj .' '. '9 /� should this document be used for construction or for establishing a boundary or fence line. 49TH As-Built Survey of: Lot 8, Block 4 North Woods Subdivision Frederic W. ner h'� N0, L.5,9946 �� !7✓lcrr I, Frederic Wagner, hereby certify that this Mortgage Inspection Survey was performed by me, or '. 11/27/2019 ��= under my direct supervision on November 27th, 2019. - Jy yyr191 IDR* * ..... OFES;IONP� ?O Fronter Surveys, LLC 650 W!58 h Ave. Suite E Anchorage, Alaska 99518 0 �IER,. 907.460.1686 - info@frontiersurveys.com PROFESSIONAL SEAL www.frontiersurveys.com Municipality of Anchorage Department of Health and Human Services m Division of Environmental Services On -Site Services Section 825 °L" Street Room 502 P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FORA SINGLE FAMILY DWELLING Parcel I.D. OE__ if73) -r3 HAA# ',4- C 1 FT 01 Expiration Date: 1. GENERAL INFORMATION Complete legal description Lot 8, Block 4, Northwoods S /D Location (site address or directions) NHN McManus Drive Current Property owner(s) John Thomson Mailing address 17343 Santa Maria Drive, Lending agency Mailing address Real Estate Agent Mailing Address Day phone 240-2020 Eagle River, AK 99577 Day phone Day phone Unless otherwise requested, HAA will be held by DHHS for pickup. HAA picked up by: 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System Public Sewer FW The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) on properties served by a single family on-site wastewater disposal and/or water supply system. DHHS also issues HAAs upon request to home owners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 07;00)' 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation based on procedures outlined in the Health Authority Approval Guidelines for the Health Authority Approval application show that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on- site water supply and/or wastewater disposal system is in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. 5 & S ENGINEERING C. Name of Firm 37034 c:agla River Loop R$aA N10s Phone c? � Address : ;ie River, Alaska 99577 Engineer's Printed Name ri oDate 6. DHHS SIGNATURE Approved for 4 bedrooms. Disapproved. Conditional approval for Additional Comments Attachments: HAA Checklist Septic System Advisory Well Flow Advisory ~ r' {dINEE_H .. ............. ¢ _• RCEERT C. COVIAN bedrooms, with the following stipulations. Maintenance Aareements Supplemental Engineer's Report Other By: a-, ZZ, Original Certificate Date: o 0 Expiration Date: (� - / Z - d 7 Reissue Date: 75-425 (Rel. 01l00)- Municipality of Anchorage n • '� Department of Health and Human Services) Division of Environmental Services1 On -Site Services Section 825 "L" Street Room 502 g�Y rd�a P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us wj'jw«'FAurY Ui- ANCHUtZAU ,IMENTALSERVIC'F1 i (907) 343-4744 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: L o T 5 0 i- C c, i.< 4. Ny: T- H w c o A j A. WELL DATA Well type � `' �-� c If A, B, or C provide PWSID # Date completed Sanitary seal Total depth ft Cased to ft FROM WELL LOG Date of test Static water level ft Well production g.p.m WATER SAMPLE RESJJS: Coliform /colonies/100 ml Nitrate Parcel I.D.: Os"/ -73/-/3 Well Log Wire perly protected hnj ei ht above round in. 9 9 ( ground) AT INSPECTION ft 9 -p.m mg/I Other bacteria colonies/100 ml Damsample: Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material ,Srs-' C Date installed JOb"t A 1 Tank size /3 gal Number of Compartments Cleanouts Y -�S Foundation cleanout Depression over tank fy e High water alarm Date of pumping N11} Pumper C. ABSORPTION FIELD DATA Date installed "19-44"1 Soil ratingg.p.d t2/f for ft2/bdrm) � � System type Length 3G- ft Width © ft Gravel below pipe 6.45 ft Total depth S rXt. ft Effective absorption area 36 c ft2 Monitoring tube Y, -f Depression over field Jv `' Date of adequacy test P'b -''`L"1 Results (Pass/Fail) For _ bedrooms Fluid depth in absorption field before test in a gal. New depth in. Elapsed Time:�(past a fluid depth in Absorption rate >= g.p.d. Any rejuvenati o.) (Y/N & type) If yes, give date 72-026 (Rev. 01/00)' D. LIFT STATION Date installed /0/ 51ci`/ Size in gallons 114 Manhole/Access -Yk�,s "Pump on" level at 4 1 in "Pump off" level at 'J'4 -5 -in High water alarm level at 3 7. J in Datum ro P c.� I,4,�a,,-j- Cycles tested DI Meets alarm & circuit requirements `Yh -S E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: %ALJ /3-t-« (.✓.3 T f .,k Septic tank/lift station on lot On adjace Absorption field on lot On adjacent lots Public sewer main Public sewer manhole/cleanout Sewer c service line Holding tank SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 13 I Property line Absorption field Water main Water service line C�' ,t Surface water % OC Drainage P Wells on adjacent lots a OD SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line `� Building foundation 4.S" Water main n Water Service line Surface water X00 4-- Driveway, parking/vehicle storage S -o Curtain drain N �N14- f Wells on adjacent lots 3-°U 4- F. COMMENTS G. ENGINEER'S CERTIFICATION ;'�;;+� „�;...; I certify that I have determined through field inspections and review of Municipal records that the above systems are in N1EE conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name 0 6-1,' 7— C • Cz wjy,,J ' � eOL'ERT C. COWAN e f w Date S /3 HAA Fee $ Waiver Fee $ Date of Payment li Date of Payment Receipt Number O� �iJ (d��' �'J Receipt Number 72-026 (Rev. 01/00)'