MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP191426
Work Type: WellSeptic Upgrade
Tax Code Number: 01422105000
Site Legal Address: T12N R3W SEC 9 LT 54 M PTN OF E2 G:2234
Effective Date
Expiration Date
t1t L' tf j
cg X<"
3epactrn nt
10/2/2019
10/1/2020
Site Mailing Address: 3137 E 84TH AVE, Anchorage
Owner: BROTHERTON DOUGLAS W & ELENA Lot Size in Sq Ft: 42505
Design Engineer: C & M Engineering Total Bedrooms: 3
This permit is for the construction of:
Q Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions:
The septic tank shall be 1000 gallons or larger.
2. The entire proposed drainfield is not within a 30 ft radius of a percolation test. Additional perk tests are
required prior to construction of the drainfield to confirm application rate. If results require a design change,
construction shall stop pending On-site review and approval of a change order. Please submit results with the
inspection report (or change order, if required).
3. A test hole is required for the alternate drainfield to confirm separations to groundwater and impermeables, as
well as percolation rate. Please submit results and any design changes with the inspection report.
4. The existing well shall be decommissioned in accordance with code. A decommissioning log shall be
submitted with the inspection report.
4-o a- b2 - J '1 C_ 0012'11 1
FS�
Received By: �v Date: /
Issued By: // li(i,(i C� 6'�� Date: 1042
MUNICIPALITY OF ANCHORAGE � � ,�/ ��{
i , �/�r�
i
lnr
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT
®t�[s
Parcel I.D. 0 05
Property owner(s) BROTHERTON
Mailing address
Site address 3137 e 84TH ave
Legal description (Sub'd., Block & Lot)
APPLICATION
Day phone 632-5267
Legal description (Township, Range & Section) T12N R3W SEC 9 LOT 54 M PTN OF E2
Lot Size 42,505 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR: APPLICATION IS AN:
TYPE OF DWELLING:
(N all that apply)
Absorption Field E] Initial ❑
Single Family (SF) ❑
Septic Tank 0 Upgrade 0
(w/wo ADU)
Holding Tank ElRenewal ElDuplex
(D) ❑
Privy ❑
Multiple Dwellings ❑
(SF and/or D)
Private Well 0
Water Storage ❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
NONE
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
C&M ENGINEERING
(Signature of property owner or authorized agent)
Permit/Rush Fees: 4 /it a �i, Waiver Fees:
Date of Payment: q/ 93 1`7'
/ Date of Payment:
Receipt Number: OA tl� IV 1) Receipt Number:
Permit No. dlc)091LI�� Waiver No.
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc
Ph: 907-854-5558
Municipality of Anchorage
Onsite Water & Wastewater Program
4700 Elmore Rd Anchorage, Ak 99507
1-11-11-1-1-,- ----RE:-Proposed-Septic System -replacement for T12N R3W-Sec9-Lot 54 -M -Portion of E2--- C01
Dear Reviewer,
We're requesting that the permit for the above referenced project be amended to change the drainfield
from a shallow trench to a 10'x65' bed as shown on the attached updated plan and supported by the
updated calculations.
The bed system will better fit the available space and is preferred by the owner.
Thank you for your time in reviewing this request. Please do not hesitate to contact me at 907-854-5558
or by email cgbalzarini(�gmail. com with any questions or concerns.
Sincerely,
Charles Balzarini, PE
10/28/19
a jN
'CHARLES G BALZARINI`
CE13854
��1wpR0�ESS10��
C&M ENGINEERING SERVICES
Ph: 907-854-5558
Municipality of Anchorage
Onsite Water & Wastewater Program
4700 Elmore Rd Anchorage, Ak 99507
RE: Proposed Septic System replacement for T12N R3W Sec9 Lot 54 M Portion of E2
Dear Reviewer,
The above referenced property is currently served by an undocumented pit type septic system which has
partially collapsed and is need of replacement.
The existing on-site well of unknown construction date reportedly does not provide sufficient flow to meet
the needs of the household. The owner wishes to drill a new deeper well further from the septic area to
better serve the property.
Our review of available documentation and field investigation show that this project will not adversely
impact any nearby wells, wastewater disposal systems, replacement disposal sites, or drainage flowing
onto and off of the subject property.
A new test hole was excavated on the subject property and a percolation test was conducted.
Included with this letter is a permit application and design package, including plans, and calculations.
Thank you for your time in reviewing this permit request. Please do not hesitate to contact me at 907-854-
5558 or by email cgbalzarini@gmail.com with any questions or concerns.
Sincerely,
Charles Balzarini, PE
9/12/19
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP191426, Rebecca Carroll, 10/02/19
1 00' WEL L RADI
U S 3 BR HOME
DRIVEWAY
100'
WEL L RADI
U S
SERVED BY
PUBLIC WATER
AND SEWER
SERVED BY
PUBLIC WATER
AND SEWER
SERVED BY
PUBLIC SEWER,
PRIVATE MULTI FAMILY WELL.
1 00 ' WEL L R ADI US
DECOMISSION
EXISTING WELL
PER MOA REQUIREMENTS
PROPOSED
NEW WELL
NEW 5' X90' SHALLOW TRENCH SYSTEM
WITH 0.5' EFFECTIVE AND 2'-0"
MOA FILTER SAND. MAX EXCAVATION DEPTH
TO BOTTOM OF ROCK IS 6'-0"
SERVED BY
PUBLIC SEWER,
PRIVATE
MULTIFAMILY
WELL
OWNER MUST HAVE
100' RADII FLAGGED
BY PROFESSIONAL
LAND SURVEYOR
PRIOR TO START OF
INSTALL WORK
DECOMISSION
UN-DOCUMENTED
PIT-SYSTEM
INSTALL (3) CONC CURBS
TO PROTECT FIELD.
6"x6"x10'-0" APPROX
LOCATE AND
REPLACE EXIST.
LINE
T12N R3W SEC9
LOT 54 N 200' - NO DOCUMENTED
WELL OR SEPTIC
T12N R3W SEC9
LOT 54 M PTN OF E2
PRIVATE ACCESS ROADT12N R3W SEC9
LOT 54 W2 OF CENTER PTN
(SEPTIC LOCATION UNKNOWN)
THESE LOTS
SERVED BY
PUBLIC
WATER
AND SEWER
TH-1
DUAL CLEANOUTS
EACH SIDE OF TANK
T12N R3W SEC9
LOT 54 E70 OF S200
T12N R3W SEC9
LOT 54 W65 OF E135
OF S200
T12N R3W SEC9
LOT 54 E 95 OF W 195
OF S200
T12N R3W SEC9
LOT 54 W 100
OF S200
10'x20' SEPTIC
RESERVE SITE
REQUIRES ADD'L
SOILS EXPLORATION
AND AWWTS
INSULATE
OVER LINE BETWEEN TANK
AND FIELD.
10
5
10 10
PRIVATE MULTIFAMILY
WELL
MODIFY/SHORE
WOOD SHED PER
OWNERS DIRECTION.
(NO FOUNDATION)
1' CONTOURS
(SLOPE DOWN TO SOUTH / WEST)
SITE LOCATION IS FLAT
C&M ENGINEERING SERVICES
907-854-5558
AREA PLAN
LEGAL DESCRIPTION: T12N R3W SEC9 LOT 54 M PTN OF E2
OWNER: BROTHERTON DATE: 09/10/19 REV: 0 DRAWN: CB REF:
SCALE: 1" = 60'
CHARLES G BALZARINI
CE-13854R
EGISTEREDPROFESSIONALE NGINEER
09/12/19
SEE SITEPLAN FOR DETAILS
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP191426, Rebecca Carroll, 10/02/19
LEGEND
Q CLEANOUT
0 MONITOR TUBE
NOTE:
THE PROPOSED SEPTIC SYSTEM MUST
BE INSTALLED GREATER THAN:
100' FROM ANY PRIVATE WELLS
200' FROM ANY PUBLIC WELLS
100' FROM ANY SURFACE WATER
10' TO ANY PROPERTY LINE OR FOUNDATION \
5' TO ANY TEST HOLES
10' TO THE HOUSE FOUNDATION
Tl 2N R3W SEC9
LOT 54 M PTN OF E2
I
� y
Nl j6
10'x20''SEPTIC�
RESERVE SITE
REQUIRES ADD'L 1
SOILS EXPLORATION,
AND AWWTS
LOCATE AND
RE LACE EXISIi \ 3'B,R H
LINE, i
MODIFY/SHORE
WOO SHED PER
NERS DIRECTION.
(N F�UNDiATION)
OW R MUST',HAVE �
100' Dll FLAGGED
B OFESSIONAL
LAND SURVEYOR
PRIOR TO START Ofv
INSTALL WORK .....
°F q�gsil
rAWco
N• r HARLES G BALZARItii
I�rr�'F6, CE -13854 . •��`���
11 ltiR;� PROFESOP�
PROPOSED
NEW WELL
DECOMISSION
EXISTING WELL
? I PER MOA REQUIR
1' CONTOURS
1 1 (SLOPE DOWN TO SOUTH /
10
1F
NEW 1000 GAL
~\ POLY TANK
�_....._.._.__.-_, PER MOA
REQ'S
DUAL CLEANOUTS
EACH SIDE OF TANK
op PRIVATE MULTIFAMILY DECOMISSION
WELL UN -DOCUMENTED
ERVED BY
UBLIC SEWER,
RIVATE MULTI FAMILY
PIT -SYSTEM
I
I
SERVED By
PUBLICSWER,
LL. PRIVATE
MULTIFA ILY
i
4Y
10
NEW 10' X65' BED SYSTEM
WITH 0.5' EFFECTIVE AND 2'-0"
MOA FILTER SAND. MAX EXCAVATION DEPTH
TO BOTTOM OF ROCK IS 6'-0"
INSULATE
OVER ALL LINES
SERVED BY
PUBLIC WATER
AND SEWER
C&M ENGINEERING SERVICES
907-854-5558
LEGAL DESCRIPTION: T12N R3W SEC9 LOT 54 M PTN OF E2
OWNER: BROTH ERTON DATE: 9/11/19 1 REV: 0 1 DRAWN: CB I REF:
Q
�
TH(ESE LOTS
NTS Cn
ERVED BY
U
PUBLIC
T)
WATER
?//W
AND
SEWER
I� Q
a -
INSTALL (1) CONC CURBS
TO PROTECT FIELD.
6"x6"x10'-0"
APPROX
SITE LOCATION IS FLAT
NEW 10' X65' BED SYSTEM
WITH 0.5' EFFECTIVE AND 2'-0"
MOA FILTER SAND. MAX EXCAVATION DEPTH
TO BOTTOM OF ROCK IS 6'-0"
INSULATE
OVER ALL LINES
SERVED BY
PUBLIC WATER
AND SEWER
C&M ENGINEERING SERVICES
907-854-5558
LEGAL DESCRIPTION: T12N R3W SEC9 LOT 54 M PTN OF E2
OWNER: BROTH ERTON DATE: 9/11/19 1 REV: 0 1 DRAWN: CB I REF:
SITE PLAN - C01
C&M ENGINEERING SERVICES
907-854-5558
Septic Design Calculations
Residence: T12N R3W SEC9 L54 M PORTION OF E2 - C01
z RESIDENCEf LOT INFO
number of bedrooms 3 br
Water usage/bedroom 150 gpd/br
Water Usage 450 gpd
CALCULATIONS ARE FOR REFERENCE PURPOSES ONLY USE DIMENSIONS SHOWN ON PLANS
Application Rate 0.7 gpd/sgft For sand liner
required absorption area 643 sgft
width(W)_ 10 ft
minimum effective depth 0.5 ft below distribution pipe see narrative
Min Required Length
MOA Sand Depth
MAX Excavation Depth
65 ft
2 ft
6 ft TO BOTTOM OF ROCK
Min Cover: 3 ft
Insulation: 2" blueboard
Effluent Pipe: 4" ASTM 3034
CALCULATIONS ARE FOR REFERENCE PURPOSES ONLY USE DIMENSIONS SHOWN ON PLANS
Calc By: CGB
�GHARLES G SALZARI€ F
OE13854
fib.
"��_ �'ROFESSI4�A v
Date: 10/28/2019
Residence:
number of bedrooms 3 br
Water usage/bedroom 150 gpd/br
Water Usage 450 gpd
type:
Application Rate 3 gpd/sqft
required absorption area 150 sqft
width (W) 10 ft
minimum effective depth 0.5 ft below distribution pipe see narrative
Min Required Length: 15 ft
MOA Sand Depth 2 ft
MAX Excavation Depth: 6
Min Cover: 3 ft
Insulation: 2" blueboard
Effluent Pipe:
Calc By: CGB Date: 9/30/2019
C&M ENGINEERING SERVICES
907-854-5558
Septic Design Calculations
RESIDENCE/LOT INFO
RESERVE DRAINFIELD
4" ASTM 3034
CALCULATIONS ARE FOR REFERENCE PURPOSES ONLY USE DIMENSIONS SHOWN ON PLANS
CALCULATIONS ARE FOR REFERENCE PURPOSES ONLY USE DIMENSIONS SHOWN ON PLANS
ft TO BOTTOM OF ROCK
T12N R3W SEC9 L54 M PORTION OF E2
BED (AWWTS CAT III)
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP191426, Rebecca Carroll, 10/02/19
CHARLES G BALZARINI
CE-13854R
EGISTEREDPROFE S S I O N ALENGINEER9/5/19
BROTHERTON
T12N R3W SEC9 LT54 M PORTION OF E2
08/22/19
NO
9/2/19
NA
TOPSOIL
GW / GP
SANDY
GRAVEL
PERCOLATION RATE EXCEEDS 1 MINUTE PER INCH
3 4
CHARLES BALZARINI CHARLES BALZARINI
09/22/19
BOH
6"
None
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP191426, Rebecca Carroll, 10/02/19