On-Site Wastewater Disposal System Permit
Permit Number: OSP191465 Effective Date: 10/22/2019
Work Type: Septic Upgrade Expiration Date: 10/21/2020
Tax Code Number: 05121104000
Site Legal Address: T15N R1W SEC 16 S2SE4SW4 G:1058
Site Mailing Address: 18005 AMONSON RD, Chugiak
Owner: WEHR MICHAEL Lot Size in Sq Ft: 762300
Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: 4
This permit is for the construction of:
Q Disposal Field 0 Septic Tank ❑ Holding Tank 0 Privy 0 Private Well 0 Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907)343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions: A COSA is required to close this permit.
•
/
Received By: --14*C Date:
Issued By: AV,•-•-• �� ��— Date: 407
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On-Site Water& Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 051-211-04
Property owner(s) MICHAEL & KAELA WEHR Day phone
Mailing address PO BOX 670836, CHUGIAK, AK 99567
Site address 18005 AMONSON RD
Legal description (Sub'd., Block& Lot) T15N R1W S16 S2SE4SW4
Legal description (Township, Range& Section)
Lot Size 762,300 Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(®all that apply)
Absorption Field ❑X Initial ❑ Single Family (SF) ❑X
(w/wo ADU)
Septic Tank ( Upgrade ❑X
Duplex (D) ❑
Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑
Privy ❑ (SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:45q5 Waiver Fees:
Date of Payment: f 0/15j20) Date of Payment:
Receipt Number:�C0523(i Receipt Number:
W
Permit No. F I1 j 4 1 I 5 Waiver No.
Permit App_:•:• ,__..:c;
DE I PARAMETERS
Pai Rl SEPTIC SYSTEM rn o x
E40OM: 4(600 gpd) rn D " ox �
N S IJE: 1500g r II z x O
�R R E: <1 MPI (SIEVE ANALYSIS `�►. a o� �o W
0mil ED - SP SAND) \ a� o N a:0 ow N
IL A NG: 1.2 GPD/SF 5, ` LOT IS VACANT &� I
UNDEVELOPED
E R 500 SF -._ \ \ \ \ I rn
DTN FACTOR: 0.5 - — \ T ' \— �' T —'r z o
--F
J B`RPTION AREA: 250 SFT
S. Y : WIDE TRENCH 4.0'ED ;�, _ _ 1 1 \ \ \ 1 V I w o
MIN INGTH: 50 LF TRUE NORTH SCALE : 1"= 60' 1 \ \ \ 1 \
[ _
61.4 795 790 785 780 775 \ \
USE: soo \ INSTALL ABSORPTION FI P \ \ 1 I \
\ 50LFx5.0'Wx4.0'E.D.,10.0T.5
. \
50.OLFx5.0'Wx4.0' E.D., 10.0' TD ` eos I \ w/ MTs & COs AT ENDS & DV \ I i I I k • o
TOTAL AREA: 250 SF I AND DCO BEFORE I I I ` \ i I �•
RESERVE SEPTIC SYSTEM(NIC) I I�RESERVE AREANIC)NO. BEDROOM: 4(600 gpd) I BASED ONAWWTS i
I Ii A•
TANK SIZE: 1500g ADVANTEX I I
,�0D
PERC RATE: <1 MPI / /I i 1 \"' � I I I ,�.,•
SOIL RATING: 1.0 GPD/SF 26 9
AREA ROD: 100 SF
REDUCTION FACTOR: 0.5I ABSORPTION FIELDiE) I ) 1 I
ADJ. ABSORPTION AREA: 50SF INSTALL 150OG SEPTIC TANK P C� I ABANDON IN PLACE I I 1 \\I
SYS. TYPE: WIDE TRENCH 4.0'ED w/ DCO AFTER I 1 I I i I i /
MIN LENGTH: 10 LF 9 I / 157.1
LOT IS VACANT & / \ \ 1 I I / / r o
UNDEVELOPED G \ \ / r / 00 d
USE: ./ a�, -•\105.1 \ i I I � r / ��� � � w �
REMOVE SEPTIC TANK \ / J`rd
10.OLFx5.O'Wx4.O' E.D., 10.0' TD E PER MOA CODE \ \ I I I ( / / �„��
TOTAL AREA: 50 SF \ I I I I I / v C) uj 0 co
Ln
WELL E I I I +darn (n (n Q C6cy)
\ 1 I I I I // Nwa (nz -JOS
�v SBD \ 1 I I 1 I / /I I I Zoo (o <
W o Q
�X
Wo°° Ln -6
_w w _ WATER LINE / / / \ i / I 1� Zor:� 00 LJ O U
WELL RADIUS ( �" �3Q �G / / / I l \ 1 ( 1 QHS z — _ n _
— ss ss — NEW SEPTIC o� / / / I / \ / i an -w Lr) I.
ABBREVIATIONS �Wl /'� W
TH TEST HOLE (/ / \ I�--� \N
(P) PROPOSED
(E) EXISTING
CO CLEAN OUT NO.
FC FOUNDATION CLEANOUT I 1 I \ 1
FS FLOW SPUTTER I I I I I \\ \ 1 1
i
MT MONITOR TUBE N0. — — I I I I I i t \ I z
TYP TYPICAL
C) Q
I r l I IOf .J
Ofw
LOT IS VACANT & I I 1 / / / r / / / o z
UNDEVELOPED ( I ( / / / / / / / / / / / Z O
0 3 (n
0
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE CONPUANCE
Pannone Engineering i C LLC OSP191465, Deb Wbckerrfuss, 10122/19
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve@panenRak.com
21 October 2019
Subject: T15N R1W S16 S2SE4SW4
Upgrade Septic System Permit Request
Design Narrative
This is a design narrative to issue a permit to install an upgrade septic system for this property. The system will serve an
existing four (4) bedroom house. The system will utilize an existing 1500g septic tank and a conventional gravity fed drain
field. This lot is served by a private well. The surrounding lots are undeveloped and there are no wells within 100' of the
proposed septic system.
1. Soils. PES performed one test hole on the property in the area of the proposed system on 09JUL19 and completed
seven day water monitoring on 09AUG19. Ground water was not observed to a depth of 16'. Bedrock was not
encountered in the test hole to 16.0. The percolation rate of the soils was 0.3mpi and a sieve analysis was performed
(results attached) resulting in a SP soil so no sand filter is required. Based on the results of the test hole and sieve
analysis, an application rate of 1.2 GPD/SF was used for a conventional wastewater.
2. Soil Absorption System Design.
a. See Sheet 1 of the design package.
3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field.
4. Topography: The existing topography on the lot generally slopes from west to the east. The proposed field is to be
installed in a slope of 8%-20% and there are no steep slopes in the area of the proposed system.
5. Drawing Markings: The Drawings are marked "For MoA Review Only." When written notification that the review is
complete and that there are no further comments received from MoA On -Site Department, the note will be removed and
"Issued for Construction" drawings will be issued.
The proposed installation will not affect the future development of this or the surrounding lots.
If you have any questions or concerns, please contact me at 745-8200.
Sincerely,
Steven R. Pannone, P.E.
Owner/Civil Engineer
Mailing: P.O. BOX 1807, Palmer-, AK 99645
Telephone: (007) 745-5200 FAX: (907) 745-5201
W SG3PEt4ND SPECIFICATIONS:
d
1 L ONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MOA
CO ONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL
LUSY EMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.55.
. QCO RACTED WORK WILL BE IN COMPLIANCE WITH MUNICIPALITY OF ANCHORAGE STANDARD
1
2
TEST HOLE
1
TOPSOIL
OR
1
m P IFICATIONS (MASS) DIVISION 10 & DIVISION 20 AS APPROPRIATE.
1W. SC E OF WORK: INSTALL NEW 150OG SEPTIC TANK & SOIL ABSORPTION SYSTEM.
OGR NDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 16 FEET BELOW EXISTING GRADE AS
3
a
SM/GP
SAND &
GRAVEL
&VI NCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE
EX NATIONS LESS THAN 16 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY.
1 T CTURES DEPICTED ON T� SITE PLAN ARE BASED UPON ONE OF THE FOLLOWING: CONCEPTUAL
O L PLAN DEVELOPED BY OWNER; A PLOT PLAN DEVELOPED BY RLS; OR A SURVEY AS -BUILT.
S
6
11.900'
3.52"
0.3
C STRUCTION SPECIFICATIONS:
7
8.399'
0
2.1. ALL EXCAVATION DEPTHS ARE ADVISORY. THEY ARE TO BE VERIFIED AND MAY BE MODIFIED BY THE
8
1 MIN
11.900'
ENGINEER IF ACTUAL FIELD CONDITIONS VARY FROM THOSE USED TO PREPARE THE DESIGN
2.2, EXCAVATE THE DRAIN FIELD. BOTTOM OF EXCAVATION SHALL BE LEVEL AND SCARIFIED, RECORD
ELEVATIONS AT BEGINNING, MIDDLE AND END OF TRENCH BOTTOM. CONSTRUCTION EQUIPMENT
SHALL NOT OPERATE ON THE FLOOR OF THE EXCAVATION. ANY MATERIAL COMPACTED BY THE
OPERATION OF THE CONSTRUCTION EQUIPMENT SHALL BE REMOVED AND REPLACED WITH
UNCOMPACTED MATERIAL.
9
10
11
SP
SAND
2.3. PLACE THE SEWER ROCK TO THE SPECIFIED DEPTHS. DO NOT CONTAMINATE SEWER ROCK WITH
NATIVE MATERIAL OR SPOILS FROM EXCAVATION. LEVEL ROCK SURFACE TO tt" PRIOR TO INSTALLING
12
6
THE PERFORATED PIPE.
2.4. ALL PIPE SHALL BE PVC CONFORMING TO ASTM D3034 OR ENGINEER APPROVED EQUAL. MINIMUM
13
1 3.79" 1
0.4
SOIL COVER SHALL BE 3 FEET OVER THE PIPE AND 4 FEET OVER THE SEPTIC TANK. ONE INCH OF
INSULATION MAY BE SUBSTITUTED FOR 1 FOOT OF SOIL COVER.
2.5. ALL INSULATION SHALL BE 2" THICK DOW HI -40 INSULBOARD OR ENGINEER APPROVED EQUAL.
CENTER INSULBOARD WIDTH OVER SEPTIC TANK OR LINES.
14
15
SM
SILTY
SAND
2.6. GEOTEXTILE SHALL BE MIRAFI 140S OR ENGINEER APPROVED EQUAL. LAP ALL JOINTS 2 FEET
MINIMUM.
16
BOH
2.7. COVER THE DISTRIBUTION PIPE WITH A MINIMUM OF 2" OF SEWER ROCK AND COVER WITH
GEOTEXTILE BEFORE PLACING INSULATION AND BACKFILL.
2.8. MATERIAL USED AS FILL SHALL BE CLEAN AND FREE OF ORGANICS, TRASH AND CONSTRUCTION
DEBRIS.
2.9. SLOPE ALL FILL MATERIAL TO DRAIN AT 2% MINIMUM SLOPE AND 3:1 MAXIMUM SLOPE AND IN SUCH
A MANNER THAT PONDING AT OR NEAR THE DRAIN FIELD DOES NOT OCCUR. THE FILL SHALL BE LEFT
AT 6" HIGHER THAN SHOWN TO ALLOW FOR SETTLEMENT. SEED SURFACE AFTER COMPLETING
DATE PERFORMED:
07/09/19
INSTALLATION AS PER MOA CODE.
2.10. RECORD THE FINISH GROUND ELEVATION OVER THE BEGINNING, MIDDLE AND END OF SYSTEM.
2.11. MAINTAIN 5' SEPARATION BETWEEN PERCOLATION HOLE AND THE DRAIN FIELD TRENCH.
2.12. EXPOSE, PUMP AND FILL LOG DISPOSAL CRIB OR CONCRETE TANK WITH SOIL TO ABANDON IAW WITH
MOA CODE IF NEEDED.
3. CONTRACTOR RESPONSIBILITIES:
3.1. THE CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH THE SITE CONDITIONS AND LOCATIONS OF
ALL LOT LINES, EASEMENTS, WELLS (E & P), SEPTIC SYSTEMS (E & P) AND SHALL MEET MINIMUM
SEPARATION DISTANCES OR AS NOTED,
3.2. THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) SHALL HAVE ANY WELL LOCATION
AND SEPTIC LOCATION STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30
FEET OF THE PROPOSED SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE
WORK.
3.3, THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS, OTHER THAN
THE ATTACHED.
3.4. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES.
3.5. THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK.
ALL SURVEYING AND LOCATES SHALL BE IN PLACE PRIOR TO NOTIFYING THE ENGINEER.
3.6. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED
DRAWINGS AND SITE CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY THE
DESIGN.
3.7. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED -LINE AS -BUILT DRAWINGS
TO THE ENGINEER. THE RED -LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS,
PIPE ELEVATIONS, AND TANK ELEVATIONS.
3.8. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE
BOTTOM OF EXCAVATION, TOP OF PIPE WITH CLEAN -OUTS AND MONITOR TUBES INSTALLED,
INSTALLED TANK AND FINAL GRADING.
4. THE CONTRACTOR SHALL SIGN THE FOLLOWING: I CERTIFY THAT ALL WORK WILL BE PERFORMED IN
ACCORDANCE WITH THE APPROVED PERMIT, AND ANY AND ALL CHANGE ORDERS, AND THAT THE
AS -BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS CONSTRUCTED.
CONTRACTOR: BY:
TITLE: DATE:
SOILS LOG
READING
DATE NET TIME
WATER
LEVEL
READING
NET DROP
RATE
(MPI)
1
09JUL19
8.398"
O
ON
Z
2
1 MIN
11.900'
3.52"
0.3
3
OO"
Z^��00WO
8.399'
0
Uj
4
1 MIN
11.900'
3.52`
0.3
5
8.105"
z
QO
6
1.5 MIN
11.900"
1 3.79" 1
0.4
WAS GROUND WATER SOIL TEST RESULTS/ANALYSIS
ENCOUNTERED? N • PERCOLATION RATE <1 (min/inch)
(Hydrologic Soils Group: HSG A)
IF YES, AT WHAT • SIEVE ANALYSIS CONDUCTED
DEPTH? -NA-' - PERC HOLE DIAMETER 6"
• TEST RUN BETWEEN 7 FT AND 8 FT.
DEPTH TO WATER AFTER - LAST THREE READINGS PROVIDED.
MONITORING? - DRY -
DATE: 09AUG19
COMMENTS: Test hole excavated by 1R'S SEPTIC SERVICES.
PERFORMED BY: DAN MORAN. I CERTIFY THAT THIS TEST
WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL
GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
AE
,It
O
X
V) Lil r-
\
I
�_
X
OX
N
O
ON
Z
ZX
X
O
\w1
O
(n X
-0-
I -N
OO"
Z^��00WO
OLr)
0
Uj
U
Z O
z L'j
tri � v
w
2
AE
Z
0,T
J.�
V) Lil r-
Y
V o
t z
L,JO�rn�
r� � M
(n (/) Q 00 Cn
til xN
Z J O Cn
Wac'
CDQ�Q
(n X
Woo
Z rn
Lnof OY
2..-}• O m<
OO"
Z^��00WO
O -I
ami
ao Z
Z O
z L'j
tri � v
�o
Z
O
f=
v
J
O
O
N
�
OZO
a O
J �
Of
O
z
QO
Li
o
v)
040.002
Client: Pannone Engineering Services
Project: 18005 Amonson Road
Date: July 14, 2019
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE CONPUANCE
OSP191465, Deb Wockerrfuss, 10122/19
G•owther Associates
Particle Size Distribution Table
(percent passing sieve size)
Sample Source
--
Sieve Size
Percent Finer
Percent Finer
Percent Finer
Percent Finer
3 inch
100
1-1/2 inch
100
3/4 inch
100
#4
86
#10
78
#40
9
#100
4
#200
3
0.02 min
Classification
Sand (SP)
1632 Bellewie Circle /Anchorage, Alaska 99515
Telephone (907) 319-2198/E mail: cr•owthera)alaska.net
XITING GRAVEL DRIVE
4Y XJ
1155.03'
NOTES:
1), ALL PROPERTY CORNERS WERE
FOUND, EXCEPT FOR THE NORTH EAST
PROPERTY COINER.
t
I AS—BUILT
N 89.59300'r w
4 _
1155.11'
HEREBY CERTIFY THAT I
HAVE PERFORMED AN
AS—BUILT SURVEY OF
THIS LOT AND ALL THE
LF
Ej OF` SWJ OF SEI OF SWJ,
HEREON ARE TRUE AND
NO ENCROACHMENTS
EXIST UNLESS SHOWN
OTHERWISE.
oc
SEJ OF SEJ OF SWl1 f4.
4 TH
J
�� Uri i,a £,.�" �
�• ..•i 'w+h`a�u ...e_� ...
Pf c k% MICHAEL R KELLER
fr LS 10684
SECTION 16, T15N, R W, SEWARD
PREMIER CONSTRUCTION
SURVEYS, LLC
,s
MERIDIAN, ALASKA
BATE OF SURVEY:
SEPTEMBER 19TH, 2019
6CAiE`
INEEE` -NUMBM
1,"=40'
PLAT NO, 9-629A
PLOT DATE
09/23/2019
=S —NAME
1t
MOA GRID NO. NW 1058
_
c�
2 STORY WOODEN HOUSE
0
v
Q
ow
404'
-
K} h
^a
h4
op
LEGEND:
Ls- LEACH FIELD
4,37.6'
TK TANK
tiet WELL
I
C CRIB
CO CLEAN OUT
P POWER POLE
T TELEPHONE POLE
XITING GRAVEL DRIVE
4Y XJ
1155.03'
NOTES:
1), ALL PROPERTY CORNERS WERE
FOUND, EXCEPT FOR THE NORTH EAST
PROPERTY COINER.
t
I AS—BUILT
I, MICHAEL R KELLER,
HEREBY CERTIFY THAT I
HAVE PERFORMED AN
AS—BUILT SURVEY OF
THIS LOT AND ALL THE
DIMENSIONS AND
INFORMATION AS SHOWN '
HEREON ARE TRUE AND
NO ENCROACHMENTS
EXIST UNLESS SHOWN
OTHERWISE.
4 TH
J
�� Uri i,a £,.�" �
�• ..•i 'w+h`a�u ...e_� ...
Pf c k% MICHAEL R KELLER
fr LS 10684
PREMIER CONSTRUCTION
SURVEYS, LLC
16425 SANDPIPER DR.
ANCHORAGE, AK 99,516
BATE OF SURVEY:
SEPTEMBER 19TH, 2019
6CAiE`
INEEE` -NUMBM
1,"=40'
PLOT DATE
09/23/2019
=S —NAME
MICHAEL WEHR .._