Loading...
HomeMy WebLinkAboutMALNARICK LT 1Onsite File Malnarick Lot 1 #012-161-07 Municipality of Anchorage On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP201030 PID Number: 012-161-07 Dwelling: ❑ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑ Upgrade Name Tal & Lydia Malnarick ABSORPTION FIELD 01 Deep Trench El Wide Trench 1­71 Bed El Mound Site Address 2609 Strawberry Road ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 907-227-9708 5 1.2 GPD/SF 9.3 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 2.3 Ft. Gravel depth beneath pipe 7.0 Ft. Subdivision Block Lot Malnarick 1 Fill added above original grade 4..2 Ft. Gravel length 45 Ft. Township Range Section Gravel width 3 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES TolTotal Septic Absorption Holding Sewer absorption area Number of trenches Dist. between trenches From Tank Lift Station Field I Tank Line 630 Ft2 Ft. Well >100' > 100, N/A N/A ' >25' TANK 9 Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity 1,530 Gal. Surface Water >1 > 100' N/A N/AInfiltrator Material Number of compartments i Lot Line ! >5' >10' I N/A N/A NA Plastic 2 f f Foundation > 10 , , >1 0N/AN/A LIFT STATION Manufacturer Capacity Remarks 2" insulation over septic tank. Gal. Alarm location Electrical installed by PIPE MATERIAL House to tank D3034 Tank to drainfield D3034 Installer Wilco Contractors grainfield D3034 CO/MTD3034 Inspector L. Tidwell / J. Millette BENCH MARK (Assumed elevation) 100 ft Inspection151 3/6/20 3/9/20 d Location and description dates:2 Top of foundation. aro 4th ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp ® OF A,4 Conditional Approval: Date ���P°°°°°° ° S �0 �. th ..49 °.....° .. .® %,�"" MICHAEL E.�ANDERSON.a 4 ffi ° �® s° No. CE-4381°• �`" 6/2/20 ����� Septic System Approved Date 7 Ld20 Fc ............... �yP�®� ®�NOVI%®®�� Note: this approval does not include well permit requirements. trcev uoluznu/ // // // // // // // // // // // // // // // // // // // // // // // // // // 105100 95FCO 100500 FEET 1"=50' 4-BDRM HOME CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND TH#1 PERMIT # OSP201030 PID # 012-161-07 MALNARICK, LOT 1 A B FCO 3.75 MH1 15.2 SV1 23.6 A B 2CO 28.25 CO1 50.85 MT 50.8 CO2 47.65 27.35 33.4 39.05 42.8 70.4 69.75 45.15 STRAWBERRY ROAD 6/30/20 ARLENE STREET20' UTILITY EASEMENT BUILDING SETBACK LINES PT#2EXISTING ALTERNATE SITE 45' LONG x 3' WIDE x 7' EFFECTIVE DEPTH ABSORPTION TRENCH 1,500 GALLON SEPTIC TANK w/20" MANWAY MH1 SV1 2CO CO2 MT CO1 EXISTING SEPTIC AREA PUBLIC WATER SERVICE LINE. PLAN AS-BUILT 1[9li[:1 LOT 6 30 F LOT 5 30' 24' LOT 4 o� 0 r P 0� 9TH •.7* �..:........... .............. �OCD Thomas H. Dr er Q4s� LS -7625 G 4A�-o fessiono� �GooO 24' L 0 N LOT 14812 LOT 15A13 N90°00'00"E 170.00'(R) Co ss LOT 1 38,141 S.F. 8 s F4. O'�,, L13. o0L D' N Cq 21.0' o 8.0' Existing c� LOT 2 House U-) o O 0 M 17 N o 18.0' 25.0' 4 r-23.0' 10.0' PO..... r� N90°00'00"W 94.00'(R) Proposed Paved O O Drive cn 0 0 0 0 6 Ln w BK422 PG38 0 0 z 20' UTIL TY ESMT. 41 N90°00'00"W 75.97'(R) 0 0 O r 7 ("I Strawberry Road Notes: 1. Steps, and Concrete walk not built at this time 2. Connected to AWWU Water 3. Record Per Plat 68-116 (R) Ordered by: Tal Malnarick Legend: Legal Description: ASbu><lt Set Rebar with Cap 0 AL. Monument Found Rebar Qi Lot 1, Septic Manhole Malnarick Subdivision Septic o Well Pavement Survey Certification: I hereby certify that a Mortgagee's Inspection was performed on the described property. Overhang • •• • Notes: It is the owner's responsibility to determine the Wood Deck • • • •' existence of any easements, covenants, or restriction • • • which are not on the recorded subdivision plat. This Concrete asbuilt shall not be used for construction or for • establishing property lines. Fence —x x— Checked by: THD Drawn by: TM Scale 1" = 40' Grid SW2127 • Job 2020-0001 Field Book: 139 Plat 68-116 Date: 7/03/2020 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP201030 Effective Date: W—W t Work Type: VkqlSeptic Initial Expiration Date: Tax Code Number: 01216107000 Site Legal Address: MALNARICK LT 1 G:2127 Site Mailing Address: 2631 STRAWBERRY RD, Anchorage Owner: MALNARICK TAL 50% & Design Engineer: FORGE ENGINEERING This permit is for the construction of: Q Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy �0ent V r Depai'Cillent 3/2/2020 3/2/2021 Lot Size in Sq Ft: 35250 Total Bedrooms: 5 El Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing C-0 RQA,l se -�o � UJO LL (Y- Y,\, S/III7.AZo Received By: In Date: 11 Issued By: %�, I Date: a S Epows MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 012-161-07 Property owner(s) Tal & Lydia Malnarick Day phone 227-9708 Mailinq address 2609 Strawberry Road Anchorage, AK 99502 Site address NHN Strawberry Road Anchorage, AK Legal description (Sub'd., Block & Lot) Malnarick, Lot 1 Legal description (Township, Range & Section) Lot Size 353250 Sq. Ft. Number of Bedrooms Five (5) I APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) f Absorption Field ❑X Initial R Single Family (SF) ❑X (w/wo ADU) Septic Tank Q Upgrade ❑ Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST, FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) s Permit/Rush Fees: <$Z25 we eec rnkre h �a �/ Waiver Fees: r Date of Payment: �'1 �o�o`ZD Date of Payment: Receipt Number: 3/J Receipt Number: Permit No. �Sp� (���Q Waiver No. f Permit App_-'-:- •�. c PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) February 26, 2020 MOA Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Subject: Malnarick, Lot 1 – NHN Strawberry Road Septic System Design Dear On-Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property. He has requested the septic system be design for five-bedrooms. We are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home and the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system on this lot or adjacent lots. The ground surface on the lot has no slopes greater than 25% within 50’ of the absorption trench. Ground contours are shown on the site plan indicating the grade and direction of flow. Storm water drainage will not impact this septic system. The new trenches will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. Please refer to the attached test hole logs and plan and profile sheets for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Michael E. Anderson, P.E. 2/26/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201030, Rebecca Carroll, 03/02/20 MALNARICK, LOT 1 LOT 16 LOT 141312 —LOT -15A13 ALTERNATE _SITE BUILDING SETBACK LINES 45' LONG x TWIDE x 7' MT CO EF_FECTIVEDEPTH "ABSORPTION TRACH LJJ PTO I (b LOT a Lti EXISTING CO TH#1 EXISTING\SEPTICAREA -260— 01, sv w MH 1,500 GALLOEPTIC Lu FCO SEPTIC w/20" MANWAY\ 41;8q�M ME k -i 'LOT, 5 - PUBLIC WATER T SERVICE LINE. 4 20' UTILITY EASEMENT -- — — — — — — — — — — — — — — — — — — — — STRAWBERRY ROAD ENGINEERING NOTE. NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 1001 OF THE OF ................ PROPOSED SEPTIC SYSTEM LEGEND CO - CLEANOUT 2CO -DOUBLE CLEANOUT ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS • 49th . . I&. * FCO - FOUNDATION CLEANOUT PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC I . ..........................•......... . SYSTEMS. FS - FLOW SPLITTER VALVE %MICHAEL E. ANDERSON j,-,vff 0 50 100 MH -MANHOLE No CE -4381 AV MT -MONITORING TUBE 00 F 3110/20 FEET o ................ SV - SEPTIC VENT 4% FESS\ 1"=50' Itl TZA %a TH -TEST HOLE MALNARICK, LOT 1 DESIGN FACTORS: SYSTEM REQUIREMENTS: 750 GPD PEAK FLOW PERK RATE: <1 MIN/IN APPLICATION RATE: 1.2 GPD/SF 7' DEEP TRENCH SYSTEM 1,500-GAL SEPTIC TANK TYPICAL TRENCH SECTION (NO SCALE) 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 3' 6" 6" 3' 7' NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY BOTTOM OF TRENCH: 10.5' BELOW GRADE FLOW LINE ELEVATION: 3.5' BELOW GRADE TOP OF TRENCH: .5' ABOVE GRADE 750 GPD / 1.2 GPD/SF / 7' DEEP / 2 SIDES = 44.6 LF TRENCH REQUIRED (45 LF SPECIFIED) 2/24/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201030, Rebecca Carroll, 03/02/20 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 1 SLOPE SLOPE SITE PLAN DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) Malnarick lot 1 2/13/2020 J. Millette DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING: IF YES @ WHAT DEPTH? - 1.02 6 3 4 012-161-07 Tal Malnarick 10:151 2 3 4 5 6 6" / 12" 10:22 10:30 10:37 10:45 10:52 OB Professional Engineers Stamp: 2/24/20 6m 10s NO NONE 2/23/20 SW/SM 6" 6" / 12"6m 08s 6" 6" / 12"6m 11s 6" 6" / 12"6m 10s 6" 6" / 12"6m 10s 6" 6" / 12"6m 08s 6" Measurements were taken to the 1/16th inch. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201030, Rebecca Carroll, 03/02/20 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: PERK #2 SLOPE SLOPE SITE PLAN DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) Malnarick lot 1 2/13/2020 J. Millette DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING: IF YES @ WHAT DEPTH?- 0.76 6 3 4 012-161-07 Tal Malnarick 10:571 2 3 4 5 6 6" / 12" 11:02 11:08 11:13 11:18 11:24 Professional Engineers Stamp: 2/24/20 4m 35s - - 6" 6" / 12"4m 25s 6" 6" / 12"4m 30s 6" 6" / 12"4m 31s 6" 6" / 12"4m 30s 6" 6" / 12"4m 32s 6" - Sample taken & submitted for gradation 2/13/2020 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201030, Rebecca Carroll, 03/02/20 NORTHERN GEOTECHNICAL ENGINEERING, INC. / TERRA FIRMA TESTING PROJECT CLIENT: Forge Engineering PROJECT NAME: Malnericic Lot I PROJECT NO.: 5665-20 SAMPLE LOC.: Lot 1 NUMBER/ DEPTH: ASTM D1557 (uncorrected) DESCRIPTION: Poorly -graded sand DATE, RECEIVED: 2/13/2020 TESTED BY: JA REVIEWED BY: RJPC 100 90 80 70 60 50 ami 40 30 w 20 10 0 145 140 120 115 % GRAVEL 0.0 % SAND 97.6 %SILT/CLAY 2.4 %MOIST. CONTENT 5.2 USCS USACOE FC %PASS. 0.02 mm %PASS. 0.002 mm SP N/A N/A N/A UNIFORMITY COEFFICIENT (C,,) 2.6 COEFFICIENT OF GRADATION (C°) 1.0 ASTM D1557 (uncorrected) N/A ASTM D4718 (corrected) N/A OPTIMUM MOIST. CONTENT. (corrected) N/A 3/4" PARTICLE SIZE ANALYSIS ASTM D422 / C136 II S, SIEVF. ppF.NMCINMCNFS I LLS. SIGVGNU�OERS 1 NYURUUGiEX 100 10 1 0.1 0.01 0.001 GRAIN SIZE (mm) GRAVEL SAND CO6nLEs SILT or CLAY Coarse Fme Coarse Medium Pme MOISTURE -DENSITY RELATIONSHIP ASTM D1 557 0 2 4 6 8 10 12 14 16 MOISTURE CON'T'ENT (V.) SIEVE ANALYSIS RESULT SIEVE SIZE(mm) SIEVE SIZE (JR) TO'T'AL% SPECIFICATION PASSING (A PASSING) N/A (ASTM D2434) 152.40 6' 76.20 3" 38.10 1.5" 19.00 3/4" 12.70 1/2" 9.50 3/8" 4.75 #4 100 2.00 410 100 0.85 #20 99 0.43 #40 88 0.25 #60 58 0.15 #100 24 0.075 #200 2.4 HYDROMETER RESULT ELAPSED DIAMETER TOTAL% TIME noun (Inm) PASSING 0 0.5 2 4 8 15 30 60 250 1440 HYDRAULIC COND. N/A (ASTM D2434) DEGRADATION N/A (ATM T-313) PLASTICITY INDEX N/A ASTM 4318 The testing services reported herein have been performed to recognized industry standards, unless otherwise noted. No other warranty is made. Should engineering interpretation or opinion be required, NGE-TFT will provide upon written request. 11301 Olive Lane - Anchorage, Alaska 99515 Phone: 907-344-5934 Fax: 907-344-5993 Ivwu,.nge-tft.com MUNICIPALITY OF ANCHORAGE Development Services Department Phone: (907)343-7904 11)�On-Site Water & Wastewater Section Fax: (907)343-7997 Certificate of On -Site Systems Approval OSC261268 Parcel ID 012-161-07 Legal description MALNARICK LT 1 Site address 2631 STRAWBERRY RD Expiration Date: f 2 z_C, Z�,fc Current property owner(s) MALNARICK TAL 50% & X The On -site system(s) is/are approved for 5 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or conditions: No comments By: Curtis Townsend Original Certificate Date 7/24/2026 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Service Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's submittal. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other MUNICIPALITY OF ANCHORAGE I\' Development Services Department 1 Phone: 907-343-7904 On -Site Water & Wastewater Section - Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 012-161-07 Complete legal description Malnarick Lot 1 Location (site address) 2631 Strawberry Road, Anchorage, AK 99502 Current property owner(s) Tal Marnarick 2. ON -SITE SYSTEMS SIZED FOR 5 BEDROOMS Day phone 907-227-9708 3. TYPE OF WATER SUPPLY: ❑ Private Well serving # dwelling units ❑ Other Non-public well as regulated by MOA ❑ Water Storage ❑ Community Well or Public 4. TYPE OF WASTEWATER DISPOSAL: ❑■ Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel 0 Plastic ❑ Concrete ❑ Fiberglass Age 6 - See advisory if steel or fiberglass older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑■ Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On -site staff to verify the accuracy of the information provided. COSA Fee $ ( O r> Date of PaymentI COSA # b S G 6 (�- Waiver Fee $ Date of Payment Waiver # COSA Application_Apr2025.doc COSA Checklist_May2025.docx COSA Checklist Legal Description: Parcel ID: If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank Date of pumping Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D.DISPOSAL FIELD DATA Which system tested (date installed) ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes go to bottom of effective. If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Adequacy test date Results Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) in Effective depth used in Effective depth remaining in Comments/Deficiencies: COSA Checklist_May2025.docx E. SEPARATION DISTANCES From Well on Lot to: (Please enter distances if less than required) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Disposal Field on Lot > 100’ Yes if No ft Neighboring Disposal Fields > 100’ Yes if No ft Sewer Line/Main > 100’ Yes if No ft Sewer Manhole/Cleanout > 100’ Yes if No ft Sewer Service/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Disposal Field(s) on Lot to: (Please enter distances if less than required) Tank to Foundation > 10’ Yes if No ft Field to Foundation > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main/Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F.ENGINEER’S COMMENTS G.CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Phone Engineer’s Printed Name Date In conducting this evaluation, FGES provided an engineering assessment of the well and/or septic system in accordance with industry practices and regulations established by the Municipality of Anchorage. The reported findings reflect the condition of the system(s) solely on the date(s) of evaluation. Separation distances were measured to readily identifiable, visible features; hidden defects, unmarked utilities, or unknown encroachments may exist that were not identified during this assessment. The operational lifespan of any well or septic system depends on numerous variable factors beyond the control of FGES, including but not limited to: localized soil conditions, seasonal groundwater fluctuations, quality of original construction, and residential water usage habits. Satisfactory test results at the time of evaluation do not guarantee future performance. Furthermore, FGES makes no representation or guarantee as to whether a code-compliant alternative well or septic system can be successfully installed on the property in the event the current system(s) fail in the future. The content, findings, and conclusions within this report are prepared for the sole and exclusive benefit of the client who retained FGES for this scope of work. Reliance upon this report by any third party—including subsequent property buyers-is strictly unauthorized and confers no legal rights or privity whatsoever.