On -Site Water System Permit
Permit Number: OSP241115
Work Type: Well Upgrade
Effective Date:
Expiration Date
Tax Code Number: 05038190000
Site Legal Address: HARMANY RANCH - EAGLET AERIE LT 10 G:0260
Site Mailing Address: 8248 HARMANY RANCH RD, Eagle River
Owner: LEGG ANDREA J & PHILLIP A
Design Engineer:
This permit is for the construction of:
UcI)artuIcnI
6/5/2024
6/5/2025
Lot Size in Sq Ft: 70872
Total Bedrooms: 6
❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions: To close this permit please submit:
1. Well Log
2. Pump Install Log
3. Water sample results
4. Well Decommissioning Log for the original well
5. Well Decommissioning Log for the well drilled on the south part of the property.
6. Owner reports that no water well was drilled under permit OSP221080.
Received By: 5 S(-{_o 7-0 L G G Date:
Issued By: �— Date: S 2
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
ON -SITE SEPTICMELL PERMIT APPLICATION
Parcel I.D. D50 -_-3 I f) -- a )
Property owner(s) ���� �� CQ,y-"G\ A'-Iye6G' Leaw Day phone �L?- gzl7-gl(),3
Mailing address
Site address
A
! Lil�lt' ILi Ur'l
U
Legal description (Sub'd., Block & Lot) E i !� i Iy> Cti,t, L� v1C�'l - �C�ri- f e i-- Pe i-i r, L t 6
Legal description (Township, Range & Section)
Lot Size Sq. Ft. Number of Bedrooms
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(N all that apply)
Absorption Field
❑
Initial ❑
Single Family (SF)
ADU)
Septic Tank
El
Upgrade
Upgrade (�
Duplex
❑
(D)
Holding Tank
ElRenewal
❑
Multiple Dwellings
❑
Privy
❑
(SF and/or D)
Private Well
Water Storage
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of prdoerty owner or authoriz�(q age
Permit/Rush Fees: 22.5' Waiver Fees:
Date of Payment:_ S / 01 u Z X Date of Payment:
Receipt Number: _ '} 7 30 Receipt Number:
Permit No. OS P ? U(J jL�5 Waiver No.
')evelopment Services\Building Safety\On Site Water and Wastewatefforms\Client FormsTermit Application.doc
v
eon
Q..d�
rn
r
LJLJ
® u:
0
_j
`� (,6
cV
O
oo
O
OR
►-
9
r
C)
Q
Of
L.d._
mi
•ps Qr °°°° o °°O°°7S
h
LL P
O ° _ `° Q N
0-)
NVA
Zd �
gL F-
� � � aOa
w86�oz ` o
OD a
0 F,W, V =
(n w z 0 0 0 Z F
LL- (n cn (n — O W�U}o wLL,LL I L
O
w UQU �
CD
7;7
LLJ
� 4 i-n C-)
tij
X g w W O
ri a �� W V m U
W
� LLJ faj) 0 U 0 0 CL,-j:
Ca:
W z LLJ 0�4]inc 0 ..
w w p m z s w
W W 0 U
w0U U? >aoIr z
CLLw� O C� Z2 W
CCIr
U too N U,
J in ��N 0 2
_ Z
- O m
.�J < >- Q Z
La
O 0 0 04
O
I af n �O
� LLi
_ a_ �3 N
O U (K m N
N Co
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
/ http://www.muni.org/onsite
q NCIIORA�E
On -Site Water System Permit
Permit Number: OSP221080 Effective Date:
Work Type: Well Upgrade
Expiration Date
Tax Code Number: 05038190000
Site Legal Address: HARMANY RANCH - EAGLET AERIE LT 10 G:0260
Site Mailing Address: 8248 HARMANY RANCH RD, Eagle River
Owner: LEGG ANDREA J & PHILLIP A
Design Engineer:
This permit is for the construction of:
o�
Departnient
4/15/2022
4/15/2023
Lot Size in Sq Ft: 70872
Total Bedrooms: 6
❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy R1 Private Well Q Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services'Department per AMC 15.65.. Provide •notification by calling (907) 343-7904 (24/7). ,
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions:
To close this permit please submit:
1. Well Log
2. Pump Install Log
3. Water sample results
4. Well Decommissioning Log for the original well
5. Well Decommissioning Log for the well drilled on the south part of the property.
Received By:
Issued By:
Date:
/( Ve dD-
Date: y � s z Z
MUNICIPALITY OF ANCHORAGE
Development Services Department r Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. D50 - --orn
Property owner(s)
Mailing address 941 A n� ayll.%bk
Site address
Legal description (Sub'd., Block & Lot) [i i iVl(� ,r✓ L v�� l - r f r +- l�P Iii r' Lf
Legal description (Township, Range & Section)
Lot Size 2:T), Sq. Ft. Number of Bedroomsy
3
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑
Initial ❑
Single Family (SF)
Septic Tank
❑
Upgrade 21
(w/wo ADU)
Holding Tank
❑
Renewal EJDuplex
(D) ❑
Privy
❑
Multiple Dwellings ❑
(SF and/or D)
Private Well
Water StorageC]
THIS APPLICATION
INCLUDES A WAIVER REQUEST FOR:
_
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of proerty owner or authoriz ag
Permit/Rush Fees: X22 S Waiver Fees:
Date of Payment: Date of Payment:
Receipt Number: 2_7S c(g7 Receipt Number:
Permit No. 05P221Og0 Waiver No.
GADevelopment Services\Building Safety\On Site Water and Wastewater\FormsUient FormsWermit Application.doc
Wockenfuss, Deborah M.
From: LEGG, PHILLIP A Col USAF PACAF 11 AF/A3/A5 <phillip.legg@us.af.mil>
Sent: Thursday, April 14, 2022 3:22 PM
To: Wockenfuss, Deborah M.
Cc: Andrea Legg
Subject: 8248 Harmany Ranch Road, Eagle River: Water Tanks
Attachments: Water Tanks.pdf
[EXTERNAL EMAIL]
Good Afternoon Ms Wochenfuss
Attached is the information for the water storage tanks. I highlighted the description:
"polyethylene plastic, NSF approved for storing potable water, BPA free"
There are 4 200 gallon tanks installed for a total of 800 gallons of storage. Also I highlighted the size, dimensions, and
_. capacity. __.....61'ear wafer-J—AAk5 —pee- owner —
Please let me know if you have any questions. Pmt
Thanks
Phil Legg
Col Phil Legg
11 AF A3/5
552-7998
From: GEREN, YVETTE R GS -08 USAF PACAF 11 AF/CD <yvette.geren.l@us.af.mil>
Sent: Thursday, April 14, 2022 3:13 PM
To: LEGG, PHILLIP A Col USAF PACAF 11 AF/A3/A5 <phillip.legg@us.af.mil>
Subject: Water Tanks
1
�V J
J ,
N. <
iE LL
to 06 M cr- (f) a
z_ W O Z o z
3.- z 1
= O W F--
F-
in a W = m o D WWZ
> � � OW � (n '(n L W
�Ix
UOWOWWOC) U cn
—O UUC3UC)>-
n
_ o�tr°d' � w
'SU) Wa��z w 0
(ifU o W
W O U
Ql
�W Ott -VSO 0 z
a) W Z OZmc O ..
wWpiT=� x0� w
Ld C) v) W a a w. 0'
za-w�o0�iw
Ul O N p
0-? UC 3)
N V)
oJ_�� co o w
z r
Lo tW- o m
wCD WWW
00
OX
00
W 0- 4
o to (n o
WU ai N
N C.
0 o e
cr
B
N F N
rn
►�
L.LJ
LL:
N
_j
N
O
C
6
�V J
J ,
N. <
iE LL
to 06 M cr- (f) a
z_ W O Z o z
3.- z 1
= O W F--
F-
in a W = m o D WWZ
> � � OW � (n '(n L W
�Ix
UOWOWWOC) U cn
—O UUC3UC)>-
n
_ o�tr°d' � w
'SU) Wa��z w 0
(ifU o W
W O U
Ql
�W Ott -VSO 0 z
a) W Z OZmc O ..
wWpiT=� x0� w
Ld C) v) W a a w. 0'
za-w�o0�iw
Ul O N p
0-? UC 3)
N V)
oJ_�� co o w
z r
Lo tW- o m
wCD WWW
00
OX
00
W 0- 4
o to (n o
WU ai N
N C.
U -N, U Tf TAIL
Municipality of Anchorage .IAN 29 g 2021
On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 2
OIC! -SITE WASTEWATER INSPECTION( REPORT
Permit Number: OSP201014 PID Number: 050-381-90
Dwelling: 0 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: FM New ❑ Upgrade
Name
Spinell Homes Inc.
ABSORPTION FIELD
❑- Dee Trench El Wide Trench E] Bed EJ Mound
Site Address
8248 Harmany Ranch Road
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
5
1 GPD/SF
11.0 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
3.0 Ft.
Gravel depth beneath pipe
8.0 Ft.
Subdivision Rlnrk Lot
--� (
t� i Ncikil'�' '` t," rSr _i J `
Fill added above original grade
3+ Ft.
Gravel length
50.0 Ft.
Township Range Section
Gravel width
2.5 Ft.
Beds: Number of Lines
n/a
Distance between lines
n/a Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Lift Station
Tank
Line
800 Ftz
1
N/A Ft.
Well
100`+
100'+
25'+
TANK 9 Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Infiltrator
Capacity
1537 Gal.
Surface Water
100'+
100'+
Material
Number of compartments
Lot Line
5'+
10'+
NA
Plastic
2
Foundation
10'+
10'+T7
LIFT STATION
Manufacturer
Capacity
Remarks
Gal.
Alarm location
Electrical installed by
PIPE MATERIAL House to tank 3034 Tank to 3034
drainfield
Installer
Ponraining Construction
Drainfield 3034 CO/MT3034
Inspector Pannone Engineering
BENCH MARK (Assumed elevation) 100 ft
Inspdatect sn v 5/11/2020 5/12/2020
Location and description
2nd
3m 6/3/2020 41"
Top of foundation wall
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
OF OF A/qs�Ih
Conditional Approval: Date
� q T 1
4.d
Steven R. Pannore
r CE 8149
@LSF ,��•
�1 s '� ����/iiiJl a .- .�
Se
Septic System
A proved (J��� Date a 3 1
p p
Note: this approval does not include well permit requirements.
(Kev Ub/UL/18)
_DESIGN PARAMETERS
PRIMARY/ RESERVE SEPTIC SYSTEM
NO. BEDROOM: 5(750 gpd) \ \
`TANK SIZE: 1530g
PERC RATE: <1 MPI \
SOIL RATING: 1 GPD/SF \ J \ \
AREA RQD: 750 SF \ \ \
SYS. TYPE: DEEP TRENCH 8'ED
\MIN LENGTH: 46.9 LF \
USED:
1 50LFx2.5'Wx8.0' E.D., 11.0' TD \
1\ `\
I DRIVEWAY \
\
m
[TOTAL AREA: 800 SF \
s \
DRM
-O
<
O
O
Z W
O
~
18.9
O
D
\ \ \ \ \ \ \ \ \ \ \
\ 5B
NEW WELL
< mz
O 0
\ \
SFEr
69.9
W
�U
- J
J 0 W
U DU
Z
< Z
73.5
NEW 1,530g SEPTIC TANK
\
73.1
U
- INSTALLED FOUNDATION CLEAN OUT, `
FCO
Z
-
AND DOUBLE CLEAN OUT,
.2 B
11.2
FILTER FABRIC
U
C1 DECK DECK ON
DCO\ `PILES - 12' DEEP =�
Mt �� T1 (BELOW BOTTOM OF TANK)
Jp \ \ \ \ TH-2 TMT u0,
\ \ O� O \ i \ \ (PES) T2
M2 ` \ CJS • `W___T
C2 .�90,
\ \ \ \ \ 3 .2 85
LOT \� lb _80-
-
p�
Z)
O= 0
m
DRAWN BY:
m
DRM
-O
<
O
O
Z W
O
~
18.9
O
D
41.0
0z
z
< mz
O 0
C 1
o
69.9
W
�U
w
J 0 W
U DU
Z
< Z
73.5
Z
<
M2
73.1
U
86.8+(FG)
Z
-
95.3
FILTER FABRIC
U
4" 0 DRAIN PIPE
II
83.8
83.8(0Ci)
DRAIN ROCK 6"
i
ABOVE PIPE INV
'I
90 8
1530g SEPTIC
�I
TANK (NEW) 90.6
_.,__...-_ -
DECK
80.8
80.8
PILE II
�I
72.8-MMMI72.8
PROFILE
NOTES:
P O1tiL' LNG SVC, C'+, LT C
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
RECORD DRAWING
FCO
DRAWN BY:
HARMANY RANCH - EAGLET AERIE, LOT 1
SPINELL HOMES INC.
NSN HARMANY RANCH ROAD
EAGLE RIVER, AK 99577
DRM
50.8
14.4
PLAN
cws
TH -1
SP/
SM
-17.0 ' 66.8
DRY 4/13/2020
DRY 5/11/2020
®� Date
OF A(,gSkk��
A
B
FCO
1k 4��tt
4.1
T1
50.8
14.4
T2
42.3
18.9
TMT
41.0
17.3
DCO
44.3
24.7
C 1
52.0
69.9
M 1
52.8
69.7
C2
73.5
45.5
M2
73.1
46.2
cws
TH -1
SP/
SM
-17.0 ' 66.8
DRY 4/13/2020
DRY 5/11/2020
®� Date
OF A(,gSkk��
Scale S
1k 4��tt
1"=50'
Pu D. NO
%
050-381-90
Steven R. Pannone 0
PERMIT NO.
p � CE 8149 \rte/
����`®
OSP201014
PROFESsmkll-
Sh2eOF
2
Certified Drilling Log
lip— DOC CO dba
BILL COLE
-P.9►ULLIVAN WATER WELLS
P.O. Box 670269, Chugiak, AK 99567 688-2759
OWNER OF Spinell Homes
LAND:
ADDRESS: 8248 Harmany Ranch Road Eagle River, AK
Bore Hole
Data
LEGAL DESCRIPTION Harmany Ranch -Eaglet Aerie L 10
DATE: 5-1-20
Depth
From
To
PERMIT OSP201014 DATE OF 3/2/20
NUMBER: ISSUE:
TAX IDENTIFICATION 05038190000
NUMBER
Is well located at approved permit location: ®Yes ❑No
Method of Drilling: ®air rotary ❑cable tool
Depth of Well: 470'
Casing Type: Steel Wall thickness .250 inches
Diameter: 6 inches, depth 468 feet
Liner type
0
2
2
5
5
9
9
35
35
69
69
97
97
104
Static Water Level: 240 feet
Recovery Rate 7 ® Bpm ❑ gph
Method of Testing Air
Well Intake Opening Type: ® open end ❑open hole
❑ Screened Start feet Stopped
❑ Perforations Start feet Stopped
Grout Type: Bentonite Volume: 50 lbs
Depth: from 2 feet, to 42 feet
Well Disinfected Upon Completion: ®yes ❑ no
Method of Disinfection: Chlorine 50 PPM
Comments:
Drilled down to 472' pulled back to 470' for better
104
140
140
320
320
325
325
378
378
402
402
426
426
432
432
460
460
466
466
472
Material.
2.-17-2
Casing Stickup
Fill
Overburden
Silty Sand & Gravel
Tight Silt & Gravel
Clay & Gravel
Clay
Clay & Gravel
Clay
Silt, Sand w/ Some Gravel Water
Clay
Silt, Sand w/ Some Gravel Water
Clay
Hardpan
Clay
Silt & Gravel Water
Hardpan w/ Water
Drillers Name: Cole Sullivan
ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality
of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough:
DOC CO dba
BILL % COLE
ULLIVAN WATER WELLS
P.O. Box 670269, Chugiak, AK 99567 688-2759
www.suilivanwaterwells.com
Pump Installation Log
Well Drilling Permit Number: SW OSP201014 Date of Issue 3/2/20
Parcel Identification Number: 05038190000
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
a
a
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP201014
Work Type: WellSeptic Initial
Effective Date:
Expiration Date
Tax Code Number: 05038190000
Site Legal Address: HARMANY RANCH - EAGLET AERIE LT 10 G:0260
Site Mailing Address: 8248 HARMANY RANCH RD, Eagle River
Owner: SPINELL HOMES INC
Design Engineer: PANNONE ENGINEERING SERVICES
This permit is for the construction of:
DCIM I'rIII ell r
3/2/2020
3/2/2021
Lot Size in Sq Ft: 70872
Total Bedrooms: 5
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
11/7-71 v C D J : (7�� 1I«v� e jNe to /Iea)
Received B)
Issued By:
Date:
Date:
.rent
Municipality of Anchorage
®r]? P.O. Box 196650 a 4700 Elmore Road
Anchorage, Alaska 99519-6650 © (907) 343-7904 a Fax (907) 343-7997
http://www.muni.org/Onsite
Development Services Division
On -Site Water and Wastewater Program
XXX * VARIANCE/WAIVER REVIEW x x x x
Waiver#: OSV201005 COSA#: Permit#:OSP201093
PID#: 050-381-90
Legal Description: Harmany Ranch - Eaglet Aerie Lt 10
Engineer: Pannone Engineering Services
Your request for a waiver of the required 50 feet horizontal separation from the absorption field to
the excessive slope has been approved. The approved separation distance is 0.0 feet. omments /
explanations or DELETE
This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-
site wastewater disposal system will require all separation distances be met or another approval
from this department.
■ ... ■ ■ .... ■ ■ .. t a K N U K H ........ t t t t ....... t ■ ■ ■ ■ ■ ■ t .... ■ ■ ■ ■ ■ ■ ■ ■ ..... ■ ■ ■ a X U X Z X t . ■ ■ I
Waiver is Granted: X Waiver is not Granted:
Date: 7 Z Zri Approved by:
Name of Review
.............................. ! ........ , ................. N; f. t a N N R t ... t t .. 11 I
**** VARIAN C E/WAIVER REVIEW ****
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/VVELL PERMIT APPLICATION
Parcel I.D. 050-381-90
Property owner(s) Spinell Homes Inc.
Mailing address 1900 W. Northern Lights, #200
Site address NSN Harmany Ranch Road
Day phone
Legal description (Sub'd., Block & Lot) Harmany Ranch - Eaglet Aerie, Lot 10
Legal description (Township, Range & Section)
Lot Size 70,872 Sq. Ft. Number of Bedrooms 5
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑X
Initial n
Single Family (SF) ❑X
(w/wo ADU)
Septic Tank
2Upgrade
❑
Duplex (D) ❑
Holding Tank
❑
Renewal ❑
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑x
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance to slope
Distance: of
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
ignature of property owner or authorized agent)
Permit/Rush Fees: ` ga o Waiver Fees:1.7
Date of Payment: /g/ U.16 Date of Payment:
Receipt Number: a/ &316 Receipt Number: 0 1603/0
Permit No. P 90IL 14/ Waiver No. 06 V g010oc;-'
Permit App__- : • . _..:c
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve(@r)anenRak.com
April 20, 2020
Subject: Harmany Ranch — Eaglet Aerie, Lot 10
Septic System and Well Install Permit Request
Design Narrative
This is a design narrative for a permit to install a new septic system and well to be issued for this property. The
proposed systems will serve a proposed five bedroom (5) bedroom house. Currently the lot is undeveloped.
This lot and the surrounding developed lots are or will be served by private wells. Required separation
distances to wells will be maintained.
1. Soils. Two test holes were performed on the lot by PES and groundwater monitoring was performed. No
groundwater was observed to a depth of 17' and bedrock was not encountered. Two test holes were
allegedly performed on this lot by Michael E. Anderson and Ben Schiller in October of 2013 and September
of 2017 (on file at the MoA). See note on plan sheet 1. Two existing test holes were located on the lot by
PES and both were found to be dry during the height of snow -melt. Based on extensive excavation during
the construction of the house foundation and re -excavation of existing test holes, no soil was found even
approaching Anderson's claimed 68 mpi. No ground water was found in any of the test hole monitor tubes.
Based on the results of the percolation tests and overall soils appearance as presented in the subdivision
soils report; an application rate of 1 gallon/day/square feet was used for a conventional wastewater system
in the area of the test hole.
2. Soil Absorption System Design.
a. See Sheet 1 of the design package.
3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The
proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches.
4. Topography: The existing topography generally slopes from the northeast to the southwest in the
area surrounding the septic system of approximately 33%, with a natural terrace just below the system that has
a slope of approximately 14%. There is a slope of approximately 38%-60%, located approximately 30 feet
downhill of this system. See slope waiver.
S. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the
review is complete and that there are no further comments is received from MoA On -Site Department, the
note will be removed and "Issued for Construction" drawings will be issued.
The proposed installation will not affect the future development of this or the surrounding lots.
Steven R. Pannone, P.E.
Anchorage Mailing: P.O. Box 100217, Anchorage, AK 99510-021.7
Palmer Mailing: P.O. Box 1.807, Palmer, AK 99545
-telephone: (907) 745-8200 FAX: (907) 745-8201.
DESIGN PARAMETERS
PRIMARY/ RESERVE SEPTIC SYSTEM- -
NO. BEDROOM: 5(750 gpd)
TANK SIZE: 1500g OT 11,
-PERC RATE: <1 MPI
SOIL RATING: 1 GPD/SF
AREA RQD: 750 SF N
SYS. TYPE: DEEP TRENCH 8'ED
MIN LENGTH: 46.9 LF
USE:
50LFx2.5'Wx8.0' E.D., 11.0' TD \`' �q�
TOTAL AREA: 800 ISF G FysFti411
0
�JQO<
O
DRIVEW Y
*UNKNOWN TH
DRY 2/11/2020 W WELL (P)
DECK 5 BR
HOUSE (P)
TH-1
1,500g SEPTIC TANK (P)
(PES)
INSTALL FOUNDATION CLEAN OUT,
DOUBLE CLEAN OUT, AND DECK
6
FLOW SPUTTER .1. UNKNOWNTH
DRY 2/11/2020
TH-2
(PES)
PRIMARY FIELD (P) 35.2
50LF x 25W x 8.0'ED x 1 1.0'TD
INSTALL CLEAN OUT AND
MONITOR TUBE AT EACH END
LOT f0
LOT 9
*NOTE:
TEST HOLE MONITOR TUBES FOUND IN THE FIELD
DO NOT MATCH TEST HOLE LOCATIONS ON SUBDIVISION
SOILS REPORT. TEST HOLE LOCATIONS SHOWN ON THIS
• SHEET ARE FROM iPHONE GPS AND ARE AT APPROXIMATELY
DRAINFIELD COVER NOTE: t10' ACCURACY* EXISTING TEST HOLES ARE NOT LABELED
MINIMUM COVER OVER DRAIN FIELD SHALL BE 2.5' WITH AS THE LOCATIONS ARE VERY DIFFERENT FROM THESUBDIVISION SOILS REPORT.
RIGID INSULATION OR 3.0' WITHOUT INSULATION. SIDE PERCOLATION TEST READINGS ON SUBDIVISION SOILS REPORT
SLOPES SHALL BE 3:1 MAX. ARE SUSPICIOUS. GROUND TOPOGRAPHY FROM SOILS
REPORT DOES NOT MATCH THE ACTUAL TOPOGRAPHY OF
THE SITE. DISCREPANCIES ARE SUCH THAT THE SUBDIVISION
SOILS REPORT DOES NOT APPEAR TO BE USABLE IN THE
DESIGN OF A SEPTIC SYSTEM. A NEW TEST
HOLE WAS PERFORMED TO VERIFY SOILS.
V
NOTES: PANNONE ENG SVC, LLC Date
OF At,
CHANGE ORDER ... .. .. 4/20/2020
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211 scale
DRAWN BY: 10, 1"=50'
49 TM
... P.I.D. NO
050
ORM HARMANY RANCH —EAGLET AERIE, LOT 10 -381-90
Pannone �l
SPINELL HOMES INC. Steven
I , OSP201014 PERMIT NO.
NSN HARMANY RANCH ROAD CE 8149
PLAN EAGLE RIVER, AK 99577 OPRO�S�oOY� Sheet
1 OF 5
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF
ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF
ON—SITE WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.55.
2. SCOPE OF WORK: INSTALL NEW SEPTIC TANK, SOIL ABSORPTION SYSTEM, AND WELL.
3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 17 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL
TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 17 FEET BELOW
EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY.
4. THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) SHALL HAVE ANY WELL LOCATION AND SEPTIC
LOCATION STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED
SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE WORK.
5. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED.
6. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES.
7. THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING
AND LOCATES SHALL BE IN PLACE PRIOR TO NOTIFYING THE ENGINEER.
8. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SITE
CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN.
9. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED—LINE AS—BUILT DRAWINGS TO THE
ENGINEER. THE RED—LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS, AND
TANK ELEVATIONS.
10. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF EXCAVATION,
TOP OF PIPE WITH CLEAN—OUTS AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING.
11. THE CONTRACTOR SHALL PROVIDE DATA (UPON WHICH THE RECORD DRAWING SHALL BE BASED) TO REPRESENT THE
PROJECT AS CONSTRUCTED. THIS DATA IN CONJUNCTION WITH THE PERIODIC FIELD OBSERVATIONS BY THE ENGINEER
(OR HIS DESIGNEE) AS REQUIRED BY AMC 15.65 DOES NOT GUARANTEE THAT THERE ARE NO HIDDEN DEFECTS BY THE
CONTRACTOR.
12. THE CONTRACTOR SHALL SIGN THE FOLLOWING:
I CERTIFY THAT ALL WORK WAS PERFORMED IN ACCORDANCE WITH THE APPEND PERMIT, AND ANY AND ALL CHANGE
ORDERS, AND THAT THE AS—BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS
CONSTRUCTED.
CONTRACTOR:
m
DA
TITLE:
ABBREVIATIONS
W WATER LINE / TH
TEST HOLE
WELL RADIUS (P)
PROPOSED
(E)
EXISTING
SS NEW SEPTIC CO
CLEAN OUT NO.
MT
MONITOR TUBE NO.
TYP
TYPICAL
NOTES:
T � �-r
��7��,�T h�am�++ �T/^� SVC,
PA1�I1VONE EN �7YC L11C
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211}r
®,�
���F'"��q,sll,
*�/
®..... /
0
Steven R..('annone.
j /
��t ' CE 8149 ��o/
���FgFOpROfESS10NP��"
X.1ti"
Dote
4/2a/2o20
CHANGE ORDER
Scale
NTS
DRAWN BY:
HARMANY RANCH — EAGLET AERIE, LOT 0
SPINELL HOMES INC.
NSN HARMANY RANCH ROAD
EAGLE RIVER, AK 99577
DRM
P.I.D. NO
050-381-90
PERMIT No.
OSP201014
PLAN
Sheet
3 OF 5
TEST HOLE 1
1
OR
ORGANICS
2
-
(PES)
1 2/4/2020
3
2
4
UNABLE TO ACCURATELY --
3
5
SP/
POORLY
5
GP
GRADED SAND
AND GRAVEL
6
7
8
9
10
BOH
11
12
13
14
15
16
17
18
19
20
DATE PERFORMED: 2/4/2020
SOILS LOG - PERCOLATION TEST
SLOPE
X
TH
KNOWN TH
/11/2020
I\
-2
S)
WAS GROUND WATER
ENCOUNTERED? N
IF YES, AT WHAT
DEPTH? -DRY
DEPTH TO WATER AFTER
MONITORING? -DRY-
DATE: 2/11/2020
TH
X
0
TH-1 _..,
NET TIME LEVEL NET DROP
-
(PES)
1 2/4/2020
f*UNKNOWN
2
DRY11
2/ /
UNABLE TO ACCURATELY --
3
READ DUE TO
4
FAST DROP
5
SLOPE
6
TH
X
PEROLATION RATE <1 (min/inch) PERC HOLE DIAMETER 6 inches
TEST RUN BETWEEN 3 FT AND 4 FT
COMMENTS: Test hole excavated by POMRANING EXCAVATION.
PERFORMED BY: Dan Moran. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE
AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
NOTES: ��+ �T ..�o''ro
FOR CONSTRUCTION PAMONE ENG SVC, L� OF A ��\ Dote
,`� • .... ! .Qs,�� 4/20/2020
P.O. BOX 100217 ANCHORAGE, AK 99510 AW
PHONE (907) 272-8218 FAX (907) 272-8211 ''GjP 'Fy�r Scale
DRAWN BY: j® *. 49 TH yk �� NTS
DRM ' • . • . — . • P.I.D. NO
HARMANY RANCH — EAGLET AERIE, LOT 10 ,,. 050-381-90
SPINELL HOMES INC. , Ste'ven R. Pannone ®PERMIT N0.
%NSN HARMANY RANCH ROAD ���'F CE 8149 .'®;' OSP201014
SOILS LOG EAGLE RIVER, AK 99577 ,{IF�F�/pSS10NP� Sheet
4 OF 5
CLOCK WATERTIME
READING DATE
NET TIME LEVEL NET DROP
READING
1 2/4/2020
10:30
2
UNABLE TO ACCURATELY --
3
READ DUE TO
4
FAST DROP
5
6
PEROLATION RATE <1 (min/inch) PERC HOLE DIAMETER 6 inches
TEST RUN BETWEEN 3 FT AND 4 FT
COMMENTS: Test hole excavated by POMRANING EXCAVATION.
PERFORMED BY: Dan Moran. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE
AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
NOTES: ��+ �T ..�o''ro
FOR CONSTRUCTION PAMONE ENG SVC, L� OF A ��\ Dote
,`� • .... ! .Qs,�� 4/20/2020
P.O. BOX 100217 ANCHORAGE, AK 99510 AW
PHONE (907) 272-8218 FAX (907) 272-8211 ''GjP 'Fy�r Scale
DRAWN BY: j® *. 49 TH yk �� NTS
DRM ' • . • . — . • P.I.D. NO
HARMANY RANCH — EAGLET AERIE, LOT 10 ,,. 050-381-90
SPINELL HOMES INC. , Ste'ven R. Pannone ®PERMIT N0.
%NSN HARMANY RANCH ROAD ���'F CE 8149 .'®;' OSP201014
SOILS LOG EAGLE RIVER, AK 99577 ,{IF�F�/pSS10NP� Sheet
4 OF 5
SOILS LOG - PERCOLATION TEST
TEST HOLE 2
SLOPE
N
OR ORGANICS
2
KNOWN TH
/11/2020 W
3
4
0
4
5
5 SP/ GRAVELLY
6
SM SAND WITH
TH- 1
6 SILT
x
�- (PES)
TH
=
-
�-_
t_ *UNKNOWN
g
,.....
,,.�� DRY 2/11/2
-2
9
S �..,
10
12
13
WAS GROUND WATER
SLOPE
14
ENCOUNTERED? N
15
IF YES, AT WHAT
TH
16
DEPTH? -DRY
x
17
DEPTH TO WATER AFTER
BOH
MONITORING? -DRY-
1$
DATE: 4/13/2020
19
READING DATE
CLOCK WATER
TIME NET TIME LEVEL NET DROP
20
READING
1 4/13/2020
2:00
DATE PERFORMED: 4/13/2020
2
UNABLE TO ACCURATELY—
3
PEROLATION RATE
<1 (min/inch) PERC HOLE DIAMETER 6 inches
TEST RUN BETWEEN 4 FT AND 5 FT
COMMENTS: Test hole excavated
by POMRANING EXCAVATION.
PERFORMED BY: Dan Moran.
I CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE
AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
NOTES:
PAMONE ENG SVC LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
.►"`~°~� ill
,. ° A�gsl�`
Dote
4/24/2020
CHANGE ORDER
( `�
PHONE (907) 272-8218 FAX 907 272-8211
1001
*
Scale
NTS
DRAWN BY:
HARMANY RANCH — EAGLET AERIE, LOT
*
�/ . ... /
®
DRM
P.I.D. NO
050-381-90
SPINELL HOMES INC.
`
• • StevenR. •Ponnone r
/ /
PERMIT NO.
NSN HARMANY RANCH ROAD
��CE 8149 \�r�,r
,��1%
OSP201014
SOILS LOG
EAGLE RIVER, AK 99577
Aw
20FES9,
Sheet
S
READ DUE TO
4
FAST DROP
5
6
040.002
Client: Pannone Engineering Services
Project: Harmany Ranch, Lot 10, Test Hole 2
Date: April 18, 2020
Crowther Associates
Particle Size Distribution Table
(percent passing sieve size)
Sample Source
--
Sieve Size
Percent Finer
Percent Finer
Percent Finer
Percent Finer
3 inch
100
1-1/2 inch
97
3/ inch
87
#4
74
#10
66
#40
11
#100
8
#200
7
0.02 mm
Classification
Gravelly Sand
with Silt
(SP -SM)
1632 Bellevue Circle /Anchorage, Alaska 99515
Telephone (90 7) 349-2198 / E mail: crowthernalaska. net
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201014, Deb Wockenfuss, 03/02/20
30
EXISTING 3.% ON,*12.5
GRADE X14%
t38% til z
DRAIN FIELD
SLOPE SECTION
/
/
/
/
/
DRAIN FIELD
NOTES: [} �T SVC,
T LLC
T �r .tea'`®�®i\� Dote
P�'"� � ►J Y Ll�l. "" Of= k a� 4/20/2020
CHANGE ORDER P.O. BOX 100217 ANCHORAGE, AK 99510 i �'' qct ��
'"''�P' Scale
DRAWN BY: PHONE (907) 272-8218 FAX (907) 272-8211 co*r%/ 1„=10
TH
ORM®...... .... ... ... % P.I.D. NO
HARMANY RANCH — EAGLET AERIE, LOT 1 ®050-381-90
SPINELL HOMES INC. Steven R. Pannone `PERMIT NO.
NSN HARMANY RANCH ROAD rrr�F�;s CE 8149..,% OSP201014
DESIGN DETAILS EAGLE RIVER, AK 99577 ,��pFESS10NA��� Sheet
2 OF 5
MUNICIPAUTY OF ANCHORAGE
^Q
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 05038190000
1. GENERAL INFORMATION
Expiration Date: z-/
Complete legal description Harmany Ranch L10
Location (site address) 8248 Harmany Ranch Rd Eagle River 99577
Current property owners) Spinell Homes Day phone
Mailing address
Real estate agent Day phone
2. TYPE OF DWELLING:
F� Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 5
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
F-71
Private Septic
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ 120 (RUSH) — Waiver Fee $
Date of Payment _a— jq— Z( Date of Payment
Receipt Number. 0,04 N 7C2 Receipt Number
COSA # OSC211056 Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures
outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or
wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated
herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and
inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State
codes, ordinances, and regulations in effect at the time of installation.
In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MoA
COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time
of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on
the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not
guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot
provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole
benefit of the owner listed above. Reliance on this report by another person is at their own risk. Pannone Engineering Services LLC highly
recommends buyers hire their own engineer to evaluate this report.
Name of Firm Pannone Engineering Services
Address P.O. Box 1807 Palmer, AK 99645
Engineer's Printed Name Steven R. Pannone P.E.
Phone (907) 745-8200
Date 2 <O-ZIq
0.
.. v . TH \ 1
6. DSD SIGNATURE .. �..
System #1 Approved for 5 bedrooms — 'r0 ' s'te'vei- P. 'Pannone
CE 14 9-
a ••�
System #2 Approved for bedrooms ¢;`%s; ��1
V3 Aw
Disapproved���'�?o
Conditional approval for bedrooms, with the following stipulations:
,.1M)))))111'',
`"^ Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
Legal Description: Harmany Ranch L10
If more than 1 septic system on lot: COSA Checklist # 1 of 1
A. WELL DATA
D4 Well log is filed with Onsite (or attached)
Date drilled 5/1120
Total depth 470 ft
Cased to 468 ft
Q Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) 18+ in.
Date of flow test for COSA new
Static water level at beginning of test 240 ft.
Comments
B. TANK DATA
Age of tank(s) new years
Tank type/material
Measured operating fluid level in septic tank new
❑ Standpipes/foundation cleanout per record drawing
Date of pumping new system
D. ABSORPTION FIELD DATA Deep Trench
Which system tested (date installed) 5/12/21
R ALL standpipes present per record drawing
Total measured depth from grade 14 ft (max)
Measured depth to pipe invert from grade 6 ft (min)
❑ N/A — pressurized field
MR Monitor tubes go to bottom of effective. If not, state
depth into effective
Parcel ID: 05038190000
Structure served by this system 1
Well production at time of test 7 gpm
Water storage tank volume gallons
Well disinfected for coliform test? F,71 Yes ❑ No
W Coliform bacteria is Negative
NitratE mg/L ❑ Nitrate less than MRL (ND)
Arsenic 5. %3 ug/L ❑ Arsenic less than MRL (ND)
Collected by Pannone Engineering
Date of Sample a -L, La j
C. LIFT STATION
❑ Required maintenance completed
Age of lift station years
Lift station material
Comments:
Adequacy test date new
Results ED Pass For 5
Fluid depth prior to test _
Water added gal
New depth in
Elapsed time min
bedrooms
in
Q Code -required soil cover over field Final fluid depth in
❑ System presoaked Absorption rate gpd
(Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) _
date of test) If yes, enter date
Gallons introduced gallons
Comments/Deficiencies:
COSA Checklist yellow sheet
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
P/1
Yes
Community Sewer Manhole/Cleanout > 100'
✓v Yes
if No
ft
❑✓ Yes
if No ft
Neighboring Tank >,100' 0 Yes
if No
ft
Private Sewer/Septic Line > 25' 17771 Yes
if No ft
Absorption Field on Lot > 100' E] Yes
if No
ft
Holding Tank > 100' Yes
if No ft
Neighboring Absorption Fields > 100'
0 Yes if No.
Water Main > 10'
Animal Containment > 50' ❑✓ Yes
if No ft
0 Yes
if No
ft
❑✓ Yes if No.
Water Service Line > 10'
0
Yes
if No
Manure/Animal Excreta Storage > 100'
If septic tank is under driveway comment below
Community Sewer Main > 75' 0 Yes
if No
ft
M Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
P/1
Yes
if No
ft
Surface Water > 100'
0 Yes if No.
Property Line > 5'
0
Yes
if No
ft
Wells on Adjacent Lots:
FV71
Absorption Field > 5'
Q
Yes
if No
ft
Private Wells > 100'
0 Yes if No.
Water Main > 10'
0
Yes
if No
ft
Community Wells > 200'
❑✓ Yes if No.
Water Service Line > 10'
0
Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10' 121 Yes if No ft If absorption field is under driveway comment below
Property Line > 10'
0
Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'
0
Yes
if No
ft
Private Wells > 100' [Zl Yes if No
Water Service Line > 10'
FV71
Yes
if No
ft
Community Wells > 200' 121 Yes if No
Surface Water > 100'
0
Yes
if No
ft
F. ENGINEER'S COMMENTS
Waiver on file for seperation distance from field to excessive slope
G. ENGINEER'S CERTIFICATION
1 certify that 1 have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
COSA Checklist yellow sheet
OF A�,,
moo.
Steven R. Pannone
p.. CE 8149 �G
ft
ft
ft
ft
ft