Loading...
HomeMy WebLinkAboutWOHLFORTH ACRES LT 1Onsite File Wohlforth Acres Lot 1 #011-122-94 Permit Number:OSP261192 Tax Code Number:01112294000 Work Type:Septic Upgrade Effective Date: Design Engineer: Site Legal Address:WOHLFORTH ACRES LT 1 G:2222 Owner:ANCHETA DEBBIE S & Site Mailing Address:7811 INGRAM ST, Anchorage Lot Size in Sq Ft:43771 Total Bedrooms:6 This permit is for the construction of: Disposal Field Septic Tank Holding Tank Privy Non-Public Water Well Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Coodinate with On-Site staff regarding preferred method. 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 7/22/2026 7/22/2027 AK Built Construction & Design, LLC. Expiration Date: þ þ ¨¨¨¨ Issued To: Issued By: Date: Date: 7/22/2026 7/22/2026 AK Built Construction & Design, LLC. Curtis Townsend MUNICIPALITY OF ANCHORAGE On-Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On-Site Wastewater Disposal System Permit ot%16. 01 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 01112294000 Property owner(s) Debbie & Robert Suenram Day phone Mailing address 7811 Ingram Street, Anchorage, AK 99502 Site address 7811 Ingram Street Legal description Wohlforth Acres Lot 1 Number of Bedrooms 6 Engineering Firm AK Built Construction & Design, LLC Building Permit Number Not Applicable 0 APPLICATION IS FOR: APPLICATION IS AN: (® all that apply) Disposal Field El Initial ❑ Septic Tank El Upgrade Holding Tank ❑ Renewal ❑ Privy ❑ Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Permit/Rush Fees: 0 Date of Payment: 2 L Permit No. May 2025 Waiver Fees: Date of Payment: Waiver No. Distance: PO Box 771203, Eagle River, AK 99577 – Phone: (907) 854-9115 Page 1 of 3 AK Built Construction & Design , LLC General Contracting - Engineering - Project Administration July 8, 2026 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Section PO Box 196650 Anchorage, AK 99519 RE: Wohlforth Acres Lot 1 – Septic System A permit is requested to upgrade a septic tank and conventional soil absorption system for the subject property. The proposed system will serve a 6-bedroom, single-family. The existing soil absorption system is flooded and no longer accepts effluent. A water sample was taken on the surface waters and confirmed the presence of Coliforms and elevated Nitrate levels. It is not fully known as to why the existing field has failed, but a septic pumper previously jetted the field lateral and removed a notable amount of sediment from the field pipe. Recent embankment construction on Kincaid Acres Lot 2E has increased stormwater flows across the back of Wohlforth Acres Lot 1. There have been multiple sediment transport events onto the subject parcel originating from the newly constructed embankment. The proposed soil absorption system is sited to be higher and out of the stormwater flow path. Wells The subject property is currently served by community water. Neighboring parcels are served by private water wells or community water. There are no neighboring wells within 100’ of the designed septic system. Soils AK Built Construction & Design, LLC performed test hole excavation and percolation testing on May 4th, 2026. Three test holes were excavated. The first test hole was excavated to twelve feet below ground surface; soils were classified as organic silt overlaying silt with sand and groundwater encountered at eight feet. Groundwater was measured again on June 16th and recorded at three feet below ground surface. Subsequent groundwater measurements were taken again on June 26th and July 3rd and the groundwater monitor tube was dry. A percolation test was conducted at four and a half feet to five feet below ground surface and resulted in a percolation rate of 4 minutes per inch. An application rate of 1.2 gallons/day/square foot shall be used for a conventional pit, deep trench or wide trench wastewater system and 0.8 gallons/day/square foot for a bed style wastewater system. The second and third test holes were excavated to thirteen and eleven feet below ground surface, respectively; soils were classified as organic silt overlying silt and silty sand and no groundwater encountered. No percolation test was taken. A fourth test hole was excavated on June 26thand soils were silt followed by a sandy silt and no groundwater encountered. A percolation test was conducted between four and a half feet and five feet below ground surface and resulted in a percolation rate of 2.8 minutes per inch. An application rate of 1.2 gallons/day/square foot shall be used for a conventional pit, deep trench or wide trench wastewater system and 0.8 gallons/day/square foot for a bed style wastewater system. Groundwater monitoring was conducted on July 3rd and the groundwater monitor tube was dry. The septic system constructed under OSP201111 had two test holes excavated to support the system design. The Engineer of Record was Michael N. Anderson, PE (CE-9469) and Mr. Anderson logged both PO Box 771203, Eagle River, AK 99577 – Phone: (907) 854-9115 Page 2 of 3 AK Built Construction & Design , LLC General Contracting - Engineering - Project Administration test holes as one foot of overburden/organics followed by 17-feet of poorly-graded sand (SP) per the Unified Soil Classification System (USCS). Mr. Anderson encountered no groundwater and observed no groundwater at least seven days later. The test holes were excavated in the vicinity of the installed soil absorption system. Wastewater disposal systems The designed wastewater disposal system is a bed system with 12” of sewer rock below the pipe invert. The designed system has the following characteristics. # Bedrooms: 6 Daily Design Flow: 900 gallons/day Tank Size: 1,750 gallons Percolation Rate: 2.8 minute/inch Soil Rating: 0.8 gallons/day/square feet Field Area Required: 1,125 square feet System Type: Bed System Width: 24 feet Minimum Length: 46.9 feet Designed Length: 50 feet Designed Field Area: 1,200 square feet Maximum Excavation Depth (from existing ground) Allowed: 6.5 feet Existing disposal site The existing soil absorption system is a 54-foot long deep trench with 72” effective depth. This existing trench will be abandoned in place. Where the proposed bed system and existing deep trench system are less than 12-feet apart, the existing trench will be removed and backfilled. Neighboring parcels with existing disposal sites do not impact the subject parcel and the proposed system will not negatively impact neighboring parcels. Drainage Site drainage is generally Northeast to Southwest. Kincaid Acres Lot 2E has a recently constructed embankment that sheds stormwater onto the subject parcel, then flows southwesterly across the back lawn, over the existing septic field, and exits the property in the southwest corner. The proposed field is sited to be outside of the primary drainage path and final grading shall be accomplished in a manner to promote sheet flow away from the proposed septic field. Topography The designed system is in the center of the property. The site slopes from northwest to southeast and then rises again as you continue east. There is no concentrated drainage flows directed over the proposed septic system. A waiver is requested to install the proposed soil absorption system not parallel to ground contours. The proposed bed system will be installed in the receiving soils across the entire soil absorption system. The proposed bed system is located in area where grades are less than ten percent. The designed system does not have probable adverse impacts to adjacent properties. PO Box 771203, Eagle River, AK 99577 – Phone: (907) 854-9115 Page 3 of 3 AK Built Construction & Design , LLC General Contracting - Engineering - Project Administration If you have any questions, please contact me. Sincerely, Robert Colles, PE AK Built Construction & Design, LLC Project Manager/Managing Member 907-854-9115 rlcolles@akbuilt.net 7/8/2026 TH TH TH W W W W W W W W W W W WWWW W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W WWWWWWWWWW W WE L L WE L L WE L L W E L L W E L L W E L L W E L L W E L L W E L L WEL L WELL WELL WELL WELL WELL WEL L WEL L WE L L WE L L WE L L WE L L TH TH TH WOHLFORTH ACRES LOT 1 10' UTILITY EASEMENT WOHLFORTH ACRES LOT 2 10 ' U T I L I T Y E A S E M E N T IN G R A M S T REKLAS CIR EXISTING 1,500-GAL SEPTIC TANK EXISTING SAS FIELD, ABANDON IN PLACE TH-02 TH-01 TH-03 GRAVEL ASPHALT 5 BEDROOM HOUSE APPROXIMATE WATER LINE DCO INSTALL 1,000-GAL SEPTIC TANK FCO APPROXIMATE 1-BED ADU KINCAID HEIGHTS LT 11 KINCAID HEIGHTS LT 8 KINCAID ACRES LT 2C KINCAID ACRES LT 2E APPROXIMATE WELL APPROXIMATE NEIGHBORING SEPTIC TANK APPROXIMATE NEIGHBORING SAS ANDERSON TH #2 ANDERSON TH #1 APPROXIMATE WELL RADIUS R 1 0 0 ' 24' 50 ' PROPOSED SAS SYSTEM MT, ONE (1) PER CORNER CO, ONE (1) AT BOTH ENDS OF EACH LATERAL 170 17 5 180 17 5 180 185 190 195 200 185 17 5 18 0 175 18 518 5 175 180 185 1 7 5 180 185 19 0 1 9 5 180 18 5 TH-04 FI L E P A T H : C: \ U s e r s \ c o l l e \ O n e D r i v e - A K B u i l t C o n s t r u c t i o n & D e s i g n \ A K B u i l t - F i l e H u b \ P r o j e c t s \ 0 1 0 6 . 0 1 7 8 1 1 I n g r a m S t S e p t i c D e s i g n \ A C A D \ 0 1 0 6 . 0 1 - S i t e P l a n . d w g PL O T D A T E : 7/ 2 2 / 2 0 2 6 AK B U I L T C O N S T R U C T I O N & D E S I G N , L L C PO B O X 7 7 1 2 0 3 EA G L E R I V E R , A K 9 9 5 7 7 (9 0 7 ) 8 5 4 - 9 1 1 5 CE R T I F I C A T E O F A U T H O R I Z A T I O N # 2 0 4 4 5 1 WO H L F O R T H A C R E S L O T 1 78 1 1 I N G R A M S T AN C H O R A G E , A K 9 9 5 0 2 AK B U I L T P R O J E C T N O : 0 1 0 6 . 0 1 C3OF 7/22/2026 DATE: TITLE: ROBERT COLLES, PE No. CE-163739R E GISTEREDPROFES S I O N A L E N GINEER 7/8/2026 Feet 0 15 30 C1 SITE PLAN NOTES: 1.KINCAID HEIGHTS LOT 8 AND LOT 11, KINCIAD ACRES LOT 2C AND 2E, AND WOHLFORTH ACRES LOT 2 ON-SITE SEPTIC SYSTEMS AND WELLS DO NOT INTERFERE WITH PROPOSED SEPTIC SYSTEM. 2.KINCAID HEIGHTS LOT 8 AND LOT 11, KINCAID ACRES LOT 2C AND 2E, AND WOHLFORTH ACRES LOT 2 ON-SITE SEPTIC SYSTEMS AND WELLS ARE NOT NEGATIVELY IMPACTED BY THE PROPOSED SEPTIC SYSTEM. SYSTEM DESIGN: 1.DESIGNED SYSTEM IS FOR WOHLFORTH ACRES LOT 1. MUNICIPALITY OF ANCHORAGE (MOA) PARCEL ID 01112294. 2.DESIGNED SYSTEM WILL SERVE A 5-BEDROOM SINGLE FAMILY HOME AND A FUTURE 1-BEDROOM ADU. 3.TEST HOLE DATA WAS COLLECTED FOR SOIL, PERCOLATION, AND GROUND WATER DATA FOR THE DESIGNED SYSTEM. 4.SEPTIC TANK CAPACITY IS A MINIMUM OF 1,000-GALLONS PLUS 250-GALLONS FOR EACH BEDROOM OVER THREE. 4.1.SEPTIC TANK SHALL BE A MINIMUM 1,750-GALLON CAPACITY TANK. 5.DISPOSAL FIELDS SHALL BE DESIGNED TO ACCEPT 150-GALLONS OF WASTEWATER PER BEDROOM PER DAY. 5.1.DESIGN FLOW = 150 GPD/BDRM x 6 BDRM = 900 GPD. 6.THE MINIMUM EFFECTIVE ABSORPTION AREA OF A DISPOSAL FIELD SHALL BE CALCULATED USING THE WASTEWATER APPLICATION RATE CORRESPONDING TO THE PERCOLATION RATE IN ANCHORAGE MUNICIPAL CODE (AMC) 15.65 TABLE 2. 6.1.PERCOLATION RATE = 2.8 MIN/IN. 6.2.APPLICATION RATE = 0.8 GPD/SF (PER AMC 15.65 TABLE 2) FOR A BED SYSTEM. 6.3.MINIMUM EFFECTIVE ABSORPTION AREA = 900 GPD / 0.8 GPD/SF = 1,125 SF 7.DISPOSAL FIELD SHALL BE A BED SYSTEM. 7.1.BED WIDTH (W) = 24 FT 7.2.MINIMUM FIELD LENGTH (L) = (ABSORPTION AREA / WIDTH) = (1,125 SF / 24 FT) = 46.9 FT 7.3.MINIMUM FIELD SIZE IS 47-FEET LONG. USE 50-FEET LONG. MATERIALS SPECIFICATIONS: 1.WASTEWATER DISPOSAL SYSTEM COMPONENTS AND MATERIALS SHALL BE APPROVED BY THE MOA IN ACCORDANCE WITH THE CURRENT EDITION OF MOA'S PUBLICATION "STANDARDS AND SPECIFICATIONS FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS". 2.COMPONENTS INCIDENTAL TO THE SEPTIC SYSTEM INCLUDING BUT NOT LIMITED TO PIPING, FITTINGS, PUMPS AND VALVES THAT ARE LISTED OR LABELED BY A MOA APPROVED ACCREDITED THIRD PARTY LISTING AGENCY FOR THE INTENDED USE DO NOT REQUIRE THE MOA SUBMITTAL/APPROVAL PROCESS. 3.SEPTIC TANKS SHALL BE CONSTRUCTED FROM DURABLE, CORROSION-RESISTANT MATERIALS, INCLUDING CONCRETE, FIBERGLASS, OR PLASTIC. SEPTIC TANKS CONSTRUCTED FROM STEEL SHALL BE COATED ON BOTH THE INTERIOR AND EXTERIOR WITH AN APPROVED POLYURETHANE LINING OR SUPERIOR MATERIAL. 4.ALL SEPTIC TANKS SHALL BE FITTED WITH WATERTIGHT COUPLINGS, APPROVED BY MOA, AT THE PUMP-OUT ATTACHMENTS AND ON THE INLET AND OUTLET OF THE TANK. 5.A SEPTIC TANK SHALL HAVE A 20" MINIMUM DIAMETER MANWAY RISER SERVING THE FIRST COMPARTMENT. THE RISER, INCLUDING THE COVER, SHALL BE INSULATED WITH 4" MINIMUM INSULATION EXTENDING 48" BELOW GRADE OR TO THE TANK INSULATION. THE INSULATION SHALL BE OF AN APPROVED TYPE SUITABLE FOR BELOW GRADE APPLICATIONS. EXPOSED INSULATION ABOVE GRADE SHALL BE PROTECTED FROM UV DAMAGE. THE RISER LID SHALL BE SECURED TO PREVENT UNINTENDED ACCESS. 6.PIPE AND FITTINGS SHALL BE IN ACCORDANCE WITH NOTE 1 AND "PIPE AND FITTINGS MATERIAL" TABLE. 7.PIPES USED IN GRAVITY DISPOSAL SYSTEMS SHALL BE 4" IN DIAMETER. 8.CLEAN OUTS SHALL BE LONG SWEEP. 9.SEWER ROCK/DRAIN ROCK SHALL BE COARSE, WASHED AGGREGATED THAT MEASURES 12" TO 2" IN DIAMETER WITH NO MORE THAN 1% PASSING THE No. 200 SIEVE. 10.BEDDING MATERIAL FOR SEPTIC TANKS SHALL BE PER MANUFACTURER'S REQUIREMENTS. 11.FILTER FABRIC USED AS A SILT BARRIER IN THE CONSTRUCTION OF ABSORPTION FIELDS SHALL BE A PERMEABLE GEOTEXTILE APPROVED FOR THE APPLICATION. 12.INSULATION USED IN THE CONSTRUCTION OF SEPTIC SYSTEMS FOR THE PURPOSES OF FREEZE PROTECTION OF DISPOSAL FIELDS AND SEPTIC SYSTEM COMPONENTS SHALL BE MINIMUM TYPE IV EXTRUDED OR EXPANDED POLYSTYRENE, 25 PSI COMPRESSIVE STRENGTH. PIPE AND FITTINGS MATERIAL PIPE TYPE OR ASTM DESIGNATION APPROVED AS PERFORATED DISPOSAL FIELD PIPE OR SOLID COLLECTOR PIPE APPROVED AS CLEAN OUT OR STANDPIPE CAST IRON **YES YES ASTM D3034 (PVC)YES YES ASTM F789 (PVC)YES YES ASTM D1785 (PVC)**YES YES ASTM D2665 (PVC)**YES YES ASTM D2751 (ABS)YES NO* ASTM D2661 (ABS)**YES YES ASTM F628 (ABS)**YES YES ASTM F810 (HDPE)YES NO *D2751 MAY BE APPROVED AS STANDPIPE MATERIAL IF THE MINIMUM WALL THICKNESS IS 0.18", SDR 23.5. **UNDERGROUND DWV PIPE MATERIALS LISTED IN UPC TABLE 701.1 (2012). CONSTRUCTION SPECIFICATIONS: 1.SEPARATION DISTANCES AS IDENTIFIED IN THE "SEPARATION DISTANCES" TABLE SHALL BE MAINTAINED. NOTIFY THE ENGINEER OF DISCOVERIES MADE DURING CONSTRUCTION THAT IMPACT SEPARATION DISTANCE REQUIREMENTS. 2.FLAG AND SURVEY ALL PROPERTY LINES, WELL RADII, AND EXISTING FIELD SEPARATIONS PRIOR TO START OF CONSTRUCTION. 3.LAYOUT ALL FIELD COMPONENTS AND LOCATIONS PRIOR TO START OF CONSTRUCTION. NOTIFY THE ENGINEER IF CONFLICTS EXIST. 4.GROUNDWATER MONITOR TUBES SHALL REMAIN IN PLACE UNTIL CONSTRUCTION BEGINS. ABANDON GROUNDWATER MONITOR TUBES BY CUTTING ONE FOOT BELOW GRADE AND ABANDON IN PLACE. IF THE GROUNDWATER MONITOR TUBE IS WITHIN FIVE FEET OF THE DISPOSAL FIELD, REMOVE THE GROUNDWATER MONITOR TUBE IN IT'S ENTIRETY. 5.TANKS WITH TWO TO FOUR FEET OF COVER SHALL BE INSULATED WITH A MINIMUM OF 2" OF APPROVED INSULATION PLACED IMMEDIATELY ABOVE THE TOP OF THE TANK. TANKS SHALL NOT HAVE LESS THAN TWO FEET OF COVER. INSULATION SHALL EXTEND 12" BEYOND THE EDGE OF TANK FOR EVERY 1" OF INSULATION PROVIDED. 6.A SEPTIC TANK SUBJECT TO BUOYANCY FORCES SHALL BE ANCHORED OR BALLASTED AS REQUIRED TO PREVENT FLOTATION REGARDLESS OF THE LIQUID LEVEL IN THE TANK. 7.A SEPTIC TANK SHALL HAVE A 4" MINIMUM STAND PIPE PROVIDING ACCESS TO OTHER COMPARTMENTS NOT SERVED BY THE MANWAY RISER. 8.PROVIDE AIR TIGHT CAPS ON ALL CLEAN OUTS AND MONITORING TUBES. 9.PROVIDE A BUILDING CLEAN OUT INSTALLED ONE TO FOUR FEET FROM THE BUILDING FOUNDATION. IF NOT PRACTICAL, A DOUBLE CLEAN OUT SHALL BE INSTALLED ON THE UPSTREAM SIDE OF THE SEPTIC TANK WITHIN TEN FEET OF THE INLET. 10.A DOUBLE CLEAN OUT SHALL BE PROVIDED WITHIN TEN FEET OF THE SEPTIC TANK OUTLET. THE OPPOSING CLEAN OUTS SHALL BE ORIENTED SUCH THAT THE CLEAN OUT CLOSEST TO THE TANK SHALL BE TO CLEAN THE LINE AWAY FROM THE SEPTIC TANK, AND THE CLEAN OUT FURTHEST FROM THE TANK SHALL BE ORIENTED TO ALLOW CLEANING TOWARD THE SEPTIC TANK. THE CLEANOUTS SHALL BE LOCATED ON UNDISTURBED SOIL. A PRESSURE SYSTEM DOES NOT REQUIRE A DOUBLE CLEAN OUT. 11.SINGLE SEGMENTS OF SUBSURFACE DISPOSAL FIELDS SHALL NOT EXCEED 100 FEET IN LENGTH. 12.THE LONG AXIS OF A DISPOSAL FIELD SHALL FOLLOW THE CONTOURS OF THE ORIGINAL GROUND. 13.THE HORIZONTAL SEPARATION DISTANCE BETWEEN THE CLOSEST EDGES OF WORKING OR DECOMMISSIONED SUBSURFACE DISPOSAL FIELDS, OR SEGMENTS OF SUBSURFACE DISPOSAL FIELDS, SHALL BE AT LEAST TWICE THE DEPTH OF THE DRAIN ROCK BELOW THE LEVEL OF THE DRAINPIPE, BUT NOT LESS THAN SIX FEET. 14.THE BOTTOM OF THE TRENCH SHALL BE LEVEL WITHIN 4". THE BOTTOM OF A WIDE TRENCH OR BED DISPOSAL FIELD SHALL BE LEVEL WITHIN 2" BEFORE PLACEMENT OF DRAIN ROCK. 15.AFTER EXCAVATION HAS EXPOSED THE DESIGNATED INFILTRATIVE SURFACE, ANY NATIVE SOIL THAT IS SMEARED SHALL BE SCARIFIED TO IMPROVE ITS POROSITY BEFORE PLACEMENT OF DRAIN ROCK. 16.PERFORATED DISTRIBUTION PIPE USED IN A SUBSURFACE DISPOSAL FIELD SHALL BE LAID LEVEL AND BEDDED WITH DRAIN ROCK EXTENDING A MINIMUM OF 2" ABOVE THE TOP OF THE DISTRIBUTION PIPE, AND LEVEL ACROSS THE ENTIRE WIDTH OF THE DRAIN FIELD. 17.NON-PRESSURIZED SUBSURFACE DISPOSAL FIELD PIPING SHALL HAVE A 4" DIAMETER CLEAN OUT CONNECTED TO BOTH ENDS OF EACH PERFORATED SEGMENT. CLEANOUTS WITHIN 20 FEET AND IN LINE WITH THE DOUBLE CLEAN OUT DOWNSTREAM OF THE SEPTIC TANK MAY BE OMITTED. 18.AT LEAST ONE 4" DIAMETER MONITORING TUBE SHALL BE INSTALLED IN EACH SEPARATE DISPOSAL FIELD SEGMENT TO ALLOW MEASUREMENT OF THE FLUID LEVEL IN THE DISPOSAL FIELD. MONITOR TUBES SHALL NOT BE CONNECTED TO THE DISTRIBUTION PIPE NETWORK. THE PORTION OF A MONITOR TUBE EXTENDING DOWN FROM THE LEVEL OF THE HORIZONTAL DISTRIBUTION PIPES TO THE BOTTOM OF THE DRAIN ROCK SHALL BE PERFORATED. THE PORTION OF THE MONITOR TUBE ABOVE THE HORIZONTAL DISTRIBUTION PIPES SHALL BE NON-PERFORATED. MONITOR TUBES SHALL BE LOCATED AT ALL ANGLE POINTS OF DISPOSAL FIELDS TO MARK THE LOCATION OF THE ABSORPTIONS SYSTEM. PRESSURIZED TRENCH DISPOSAL FIELDS THAT DO NOT HAVE CLEAN OUT PIPES SHALL HAVE A MONITOR TUBE WITHIN ONE FOOT OF EACH END OF INDIVIDUAL TRENCH SEGMENTS. PRESSURIZED BED DISPOSAL FIELDS THAT DO NOT HAVE CLEAN OUT PIPES SHALL HAVE A MONITORING TUBE WITHIN ONE FOOT OF EACH CORNER OF THE BED. 19.AN APPROVED PERMEABLE GEOTEXTILE SILT BARRIER SHALL BE INSTALLED COVERING THE ENTIRE TOP SURFACE OF THE DRAIN ROCK PRIOR TO BACKFILL. 20.THE DISPOSAL FIELD COVER SHALL BE A MINIMUM OF TWO FEET DEEP, OVER THE TOP OF THE DRAIN ROCK. IF THE DISPOSAL FIELD COVER IS LESS THAN THREE FEET, THE DISPOSAL FIELD SHALL BE INSULATED WITH 2" OF APPROVED RIGID BOARD INSULATION. MINIMUM SOIL COVER OVER THE INSULATION SHALL BE ONE FOOT. INSULATION SHALL EXTEND 12" BEYOND THE EDGE OF TANK FOR EVERY 1" OF INSULATION PROVIDED. 21.THE FINISH GRADE OVER A SUBSURFACE DISPOSAL FIELD SHALL BE MOUNDED A MINIMUM OF 6" ABOVE ADJACENT GROUND TO PREVENT THE FORMATION OF A DEPRESSION AFTER THE BACKFILL HAS SETTLED. 22.UPON COMPLETION OF CONSTRUCTION ALL CLEAN OUTS AND MONITOR TUBES SHALL BE ABOVE FINAL GRADE A MINIMUM OF TWO FEET, A MAXIMUM OF 4 FEET, BE WATER TIGHT, AND LOCATED BY SWING-TIE MEASUREMENTS TO ALLOW YEAR-ROUND LOCATION AND ACCESS. SEPARATION DISTANCES SEPTIC TANK SOIL ABSORPTION SYSTEM PROPERTY LINE 5 FEET 10 FEET WATER MAIN/WATER SERVICE LINE 10 FEET 10 FEET BUILDING FOUNDATION 10 FEET 10 FEET DECKS/STAIRS >30" ABOVE GRADE 5 FEET 10 FEET SURFACE WATER 100 FEET 100 FEET PRIVATE WELL 100 FEET 100 FEET PUBLIC WATER SUPPLY SEE 18 AAC 80 SEE 18 AAC 80 >25% SLOPE >10' TALL -50 FEET >25% SLOPE <10' TALL -25 FEET SUBSURFACE DRAIN -GREATER OF 10 FEET OR TWO TIMES GRAVEL DEPTH SOIL ABSORPTION SYSTEM -GREATER OF 6 FEET OR TWO TIMES GRAVEL DEPTH WATER TABLE -4 FEET IMPERMEABLE LAYER -6 FEET INSPECTIONS: 1.AN ON-SITE WASTEWATER DISPOSAL SYSTEM SHALL NOT BE BACKFILLED, COMPLETED, OR USED UNTIL THE ENGINEER HAS INSPECTED AND TAKES NO EXCEPTION TO THE INSTALLATION. 2.NOTIFY THE ENGINEER 48 HOURS IN ADVANCE OF ANTICIPATED CONSTRUCTION. 3.THE ENGINEER WILL MEET WITH THE CONTRACTOR PRIOR TO CONSTRUCTION TO DISCUSS THE FOLLOWING, 3.1.PRECONSTRUCTION MEETING TO DISCUSS CONSTRUCTION PROCEDURES AND DESIGN REQUIREMENTS. 3.2.VERIFY SITE CONDITIONS CONFORM TO THE DESIGN PLANS AND PERMIT. 3.3.VERIFY THE PROJECT LAYOUT CONFORMS TO THE DESIGN PLANS AND PERMIT. 4.THE ENGINEER SHALL PERFORM A BOTTOM OF HOLES INSPECTION FOR THE SEPTIC TANK AND DISPOSAL FIELD. 5.THE DISPOSAL FIELD REQUIRES THE FOLLOWING INSPECTIONS, 5.1.AFTER EXCAVATION OF ALL NATIVE MATERIAL HAS BEEN COMPLETED, BUT PRIOR TO PLACEMENT OF FILTER SAND AND/OR DRAIN ROCK. THE PURPOSE OF THIS INSPECTION IS TO ALLOW VERIFICATION THAT THE NATIVE MATERIAL CONFORMS TO THE SOILS LOG AND THE EXCAVATION IS TO THE CORRECT DEPTH. 5.2.AFTER THE PLACEMENT OF FILTER SAND, IF UTILIZED. 5.3.AFTER THE PLACEMENT OF DRAIN ROCK, AND INSTALLATIONS OF DISTRIBUTION LINES, CLEAN OUTS, AND MONITOR TUBES, BUT PRIOR TO PLACEMENT OF INSULATION, SILT BARRIER, OR BACKFILL. 5.4.AFTER THE SYSTEM HAS BEEN BACKFILLED TO VERIFY FINAL GRADING AND THE LOCATION OF ALL STAND PIPES. 6.THE SEPTIC TANK REQUIRES THE FOLLOWING INSPECTIONS, 6.1.AFTER THE TANK IS SET IN PLACE WITH DISTRIBUTION PIPES AND CLEAN OUTS INSTALLED, BUT PRIOR TO BACKFILL. 6.2.AFTER THE TANK HAS BEEN BACKFILLED TO VERIFY FINAL GRADING, ELECTRICAL EQUIPMENT INSTALLATION, AND THE LOCATION OF ALL STAND PIPES. FI L E P A T H : C: \ U s e r s \ c o l l e \ O n e D r i v e - A K B u i l t C o n s t r u c t i o n & D e s i g n \ A K B u i l t - F i l e H u b \ P r o j e c t s \ 0 1 0 6 . 0 1 7 8 1 1 I n g r a m S t S e p t i c D e s i g n \ A C A D \ 0 1 0 6 . 0 1 - S p e c s . d w g PL O T D A T E : 7/ 2 2 / 2 0 2 6 AK B U I L T C O N S T R U C T I O N & D E S I G N , L L C PO B O X 7 7 1 2 0 3 EA G L E R I V E R , A K 9 9 5 7 7 (9 0 7 ) 8 5 4 - 9 1 1 5 CE R T I F I C A T E O F A U T H O R I Z A T I O N # 2 0 4 4 5 1 WO H L F O R T H A C R E S L O T 1 78 1 1 I N G R A M S T AN C H O R A G E , A K 9 9 5 0 2 AK B U I L T P R O J E C T N O : 0 1 0 6 . 0 1 C3OF 7/22/2026 DATE: TITLE: ROBERT COLLES, PE No. CE-163739R E GISTEREDPROFES S I O N A L E N GINEER 7/8/2026 C2 SPECIFICATIONS TH TH TH TH TH TH 0+00 0+10 0+20 0+30 0+40 0+50 0+60 0+70 GRAVEL EXISTING 1,500-GAL SEPTIC TANK EXISTING SAS FIELD, ABANDON IN PLACE TH-02 TH-01 TH-03 PROPOSED SAS FIELD MT, ONE (1) PER CORNER DCO 4"Ø ABS SCH 40 SEWER PIPE INSTALL 1,000-GAL SEPTIC TANK 4"Ø ABS SCH 40 SEWER PIPE INSTALL 4"Ø PVC SDR 35 PERFORATED PIPE ANDERSON TH #2 CO AT BOTH ENDS OF EACH LATERAL APPROXIMATE 1-BED ADU FINAL GRADE CUT LIMITS APPROXIMATE TANK EXCAVATION LIMITS FCO 5-BED HOUSE 175 180 175 18 0 18 5 185 SS-E1 SS-1 SS-2 SS-3 SS-4 SS-5 SS-6 SS - 1 1 SS - 1 2 SS - 1 3 SS - 1 4 SS - 1 0 SS - 9 SS - 8 SS - 7 5' 6.5' FINAL GRADE FILL LIMITS 6.5' 12.5' TH-04 12' EXISTING DEEP TRENCH SAS WITHIN 12' OF PROPOSED BED SAS IS TO BE REMOVED 160 165 170 175 180 160 165 170 175 180 0+00 0+10 0+20 0+30 0+40 0+50 0+60 0+70 SEPTIC TANK, SEE DETAIL ORIGINAL GRADE FINAL GRADE SS-E1 SS-1 SS-2 SS-3 SS-4 ELEV = 167.97' ELEV = 169.47' ELEV = 173.64' ELEV = 173.87'ELEV = 173.99' ELEV = 173.76' SS-5 SS-6 3' 6'6'6' 3' -0.5%-5.0% 166.2 167.5 170.0 172.5 175.0 177.5 166.2 167.5 170.0 172.5 175.0 177.5 0 5 10 15 20 25 300-5-10-15-20-25-30 SEE ORIGINAL GRADE FINAL GRADE ELEV = 167.97 ELEV = 169.47 ELEV = 173.56 ELEV = 173.66 ELEV = 174.16 ELEV = 174.47 SS-9 SS-13 -1.0%-5.0% -50.0% WYE 18 BEND CLEAN OUT SEWER LONG SWEEP 14 BEND PERFORATED PIPE CLEAN OUT 4"Ø MONITOR TUBE PERFORATED IN SEWER ROCK LAYER GRADE 24" FERNCO COUPLING 4" CLEAN OUT JIM CAP ORENCO ACCESS LID 4" PLUS URETHANE FOAM ORENCO ULTRA-RIB RISER TUBING 4" URETHANE FOAM 102" 64" 58" 49"51" INTERIOR BAFFLE, TO BE REMOVED 12" SEWER ROCK 4" PERFORATED LATERAL 2" SEWER ROCK COVER SEPERATION FABRIC 3' MIN SOIL COVER PIPE TABLE ID SS-1 SS-2 SS-3 SS-4 SS-5 SS-6 SS-7 SS-8 SS-9 SS-10 SS-11 SS-12 SS-13 SS-14 ∅ 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" LENGTH 7.52' 7.72' 3.00' 6.00' 6.00' 6.00' 23.00' 23.00' 23.00' 23.00' 23.00' 23.00' 23.00' 23.00' SLOPE 2.00% 2.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% 0.00% INLET LOCATION N:2795427.5920 E:3036085.2352 N:2795427.0979 E:3036100.2319 N:2795426.9244 E:3036107.9499 N:2795426.9244 E:3036110.9499 N:2795426.9244 E:3036116.9499 N:2795426.9244 E:3036122.9499 N:2795426.9244 E:3036110.9499 N:2795426.9244 E:3036116.9499 N:2795426.9244 E:3036122.9499 N:2795426.9244 E:3036128.9499 N:2795426.9244 E:3036110.9499 N:2795426.9244 E:3036116.9499 N:2795426.9244 E:3036122.9499 N:2795426.9244 E:3036128.9499 INLET ELEV 169.43 169.12 168.97 168.97 168.97 168.97 168.97 168.97 168.97 168.97 168.97 168.97 168.97 168.97 OUTLET LOCATION N:2795427.3402 E:3036092.7514 N:2795426.9244 E:3036107.9499 N:2795426.9244 E:3036110.9499 N:2795426.9244 E:3036116.9499 N:2795426.9244 E:3036122.9499 N:2795426.9244 E:3036128.9499 N:2795449.9244 E:3036110.9499 N:2795449.9244 E:3036116.9499 N:2795449.9244 E:3036122.9499 N:2795449.9244 E:3036128.9499 N:2795403.9244 E:3036110.9499 N:2795403.9244 E:3036116.9499 N:2795403.9244 E:3036122.9499 N:2795403.9244 E:3036128.9499 OUTLET ELEV 169.28 168.97 168.97 168.97 168.97 168.97 168.97 168.97 168.97 168.97 168.97 168.97 168.97 168.97 OL SANDY ML BOH TH-04 172.9' 160.9' 173.4' FI L E P A T H : C: \ U s e r s \ c o l l e \ O n e D r i v e - A K B u i l t C o n s t r u c t i o n & D e s i g n \ A K B u i l t - F i l e H u b \ P r o j e c t s \ 0 1 0 6 . 0 1 7 8 1 1 I n g r a m S t S e p t i c D e s i g n \ A C A D \ 0 1 0 6 . 0 1 - S e p t i c . d w g PL O T D A T E : 7/ 2 2 / 2 0 2 6 AK B U I L T C O N S T R U C T I O N & D E S I G N , L L C PO B O X 7 7 1 2 0 3 EA G L E R I V E R , A K 9 9 5 7 7 (9 0 7 ) 8 5 4 - 9 1 1 5 CE R T I F I C A T E O F A U T H O R I Z A T I O N # 2 0 4 4 5 1 WO H L F O R T H A C R E S L O T 1 78 1 1 I N G R A M S T AN C H O R A G E , A K 9 9 5 0 2 AK B U I L T P R O J E C T N O : 0 1 0 6 . 0 1 C3OF 7/22/2026 DATE: TITLE: ROBERT COLLES, PE No. CE-163739R E GISTEREDPROFES S I O N A L E N GINEER 7/8/2026 4 C3 4 C3 1 C3 TYP DOUBLE CLEAN OUT 2 FIELD LATERAL CLEAN OUT C3 3 TYP MONITORING TUBE C3 5 1,000-GAL SEPTIC TANK C3 4 SAS SECTION C3 C3 SEPTIC SYSTEM NOTE: 1.FINAL GRADING SHALL SHED WATER TO THE SOUTHEAST. GRADING IS -0.5% TO THE EAST AND -1% TO THE SOUTH OVER THE SEPTIC FIELD. 2.SEPTIC SYSTEM TO BE CONSTRUCTED WITH EQUIPMENT OF SUFFICIENT SIZE TO PREVENT TRACKING ACROSS INFILTRATIVE SURFACE OR CONSTRUCTED IN ZONES TO PREVENT TRACKING ACROSS INFILTRATIVE SURFACE. COMPACTION OF THE INFILTRATIVE SURFACE SHALL BE AVOIDED. Feet 0 10 20 TH TH TH W WELL WE L L TH TH TH ROBERT SUENRAM WOHLFORTH ACRES LT 1 05/04/26 S012 N004 W09 ROBERT COLLES, PE 05/04/26 X X YES AK BUILT OL BOH Robert Colles, PE No. CE-163739 R E GISTEREDPROFES S I O N A L E N GINEER 06/16/2026 1 2 3 05/04/26 05/04/26 05/04/26 -DRY 6" -18 5/8"2 5/8" -18 3/8"2 3/8" 4 6" 4.5 5.0 8FT 0:30 0:10 0:10 ML 05/04/26 -18 1/16"2 1/16"0:10 05/04/26 -18 1/4"2 1/4"0:10 05/04/26 -18 7/16"2 7/16"0:10 05/04/26 -18 1/2"2 1/2"0:10 4 5 6 7 06/16/26 3FT THIS SOIL LOG REPRESENTS TH-01. TH-01 TH TH TH W WELL WE L L TH TH TH ROBERT SUENRAM WOHLFORTH ACRES LT 1 05/04/26 S012 N004 W09 ROBERT COLLES, PE 05/04/26 X X NO AK BUILT OL BOH Robert Colles, PE No. CE-163739 R E GISTEREDPROFES S I O N A L E N GINEER 06/16/2026 ML NO PERCOLATION TEST PERFORMED. NO GROUNDWATER MONITORED. THIS SOIL LOG REPRESENTS TH-02. SM N/A TH-02 N/A N/A TH TH TH W WELL WE L L TH TH TH ROBERT SUENRAM WOHLFORTH ACRES LT 1 05/04/26 S012 N004 W09 ROBERT COLLES, PE 05/04/26 X X NO AK BUILT OL BOH Robert Colles, PE No. CE-163739 R E GISTEREDPROFES S I O N A L E N GINEER 06/16/2026 ML NO PERCOLATION TEST PERFORMED. NO GROUNDWATER MONITORED. THIS SOIL LOG REPRESENTS TH-03. SM N/A TH-03 N/A N/A TH TH TH W WELL WE L L TH TH TH ROBERT SUENRAM WOHLFORTH ACRES LT 1 06/26/26 S012N004W SEC 09 ROBERT COLLES, PE 06/26/26 X X NO AK BUILT BOH Robert Colles, PE No. CE-163739 R E GISTEREDPROFES S I O N A L E N GINEER 7/8/2026 SANDY ML THIS SOIL LOG REPRESENTS TH-04. N/A NONE 06/26/26 06/26/26 06/26/26 06/26/26 06/26/26 06/26/26 06/26/26 19 3/8" 19 3/4" 19 3/4" 19 3/4" 19 5/8" 19 3/4" 19 3/4" 3 3/8" 3 3/4" 3 3/4" 3 3/4" 3 3/4" 3 3/4" 3 5/8" :10 :10 :10 :10 :10 :10 :10 - - - - - - - 2.8 4.5 5.0 6" 1 2 3 4 5 6 7 TH-04 OL 7/3/2026 CO I N G R A M S T LOT 2 LOT 1 LOT 2C LOT 2E (N 89°49' 1 0 " E 1 8 9 . 8 7 ' ) (N 89°42'33" E 1 0 0 . 6 0 ' ) (S 0 0 ° 0 0 ' 0 0 " E 1 5 1 . 6 5 ' ) (N 89 ° 5 7 ' 0 0 " W 2 8 9 . 6 3 ' ) (N 0 0 ° 1 9 ' 0 4 " W 1 5 0 . 2 9 ' ) (10' UTILITY E S M T . ) (1 0 ' U T I L I T Y E S M T . ) 30' 30' PP U TH CO CO CO CO CO CO CO MH 42 . 0 ' 16.0' 26 . 2 ' 34.0' 16 . 0 ' 36.2' 16 . 0 ' 2.0' 26 . 2 ' 24.0' 12 . 0 ' 4.0' 12 . 0 ' 8.0' 18 . 0 ' 20.2' RESIDENCE TESTHOLE? PO R C H CO V E R E D 33.5' 168.0' 32.7' 49.8' LEGEND EDGE OF GRAVEL DRIVEWAY UTILITY PEDESTAL OVERHEAD UTILITIES POWER POLE EDGE OF ASPHALT ( )RECORD DATA PER PLAT #2017-7 SEPTIC PIPE SEPTIC TANK LID TEST HOLE MONITORING TUBE MH CO TH U PP DECK CONCRETE TIMBERLINE SURVEYING AND MAPPING17035 BARONOFF AVEEAGLE RIVER, AK 99577907-242-5320ryan@timberlinealaska.com FILE NO.: 26.107SCALE: 1" = 30 FEETDATE: 6/10/2026SHEET: 1 of 1 MOA GRID: SW2222 SCALE: 1" = 30 FEET(11"x17") 30'0'60' AS-BUILT OF: ADDRESS: 7811 INGRAM ST, ANCHORAGE, AKLOCATED IN: ANCHORAGE RECORDING DISTRICT LOT 1WOHLFORTH ACRESPLAT #2017-7 ASPLS MORTGAGE LOCATION SURVEY NOTES: NO TITLE REPORT WAS PERFORMED FOR THIS SURVEY, EASEMENTS SHOWN PER THE RECORD PLAT. THERE MAY BE ADDITIONAL EASEMENTS NOT SHOWN HEREON. THIS MORTGAGE LOCATION SURVEY HAS BEEN PREPARED IN ACCORDANCE WITH ASPLS MORTGAGE LOCATION SURVEY STANDARDS. IT IS A REPRESENTATION OF THE CONDITIONS THAT WERE FOUND AT THE TIME OF THE SURVEY. THIS SURVEY DOES NOT CONSTITUTE A BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACIES THAT A SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. THE INFORMATION CONTAINED IN THIS DRAWING SHALL NOT BE USED TO ESTABLISH ANY FENCE, STRUCTURE, OR OTHER IMPROVEMENTS. UNLESS GROSS NEGLIGENCE IS DISCOVERED, THE LIABILITY EXTENT OF THE PREPARER SHALL BE LIMITED TO THE AMOUNT OF FEES COLLECTED FOR SERVICES IN PREPARATION OF THIS PRODUCT. 6/10/2026 A K A F AL TS TA E O 49 TH S Ryan G. Johnson No. 192159 REGISTERED PROFESSIO N A L L A N D SURVEYOR iviumclpanty or,vncnorage On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 2 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP201111 PID Number: 011-122-94 Dwelling: ❑ Single Family (SF) ❑ with ADU ❑ D Duplex p (D) ❑Two Single Family Project: IME New ❑Upgrade Name SUENRAM ABSORPTION FIELD ❑ Deep Trench El Wide Trench El Bed ❑ Mound ❑ other Soil Rating ITotal depth from original grade 1.2 GPD/SF 9 Ft. Depth to pipe invert from original grade Gravel depth beneath pipe 3.0 Ft. 6. 0 Ft. Site Address 7811 INGRAM ST Phone Number of Bedrooms 5 LEGAL DESCRIPTION Subdivision Block Lot WOHLFORTH ACRES LT 1 Fill added above original grade 1'+ Ft. Gravel length 54 Ft. Township Range Section Gravel width 2.0 Ft. Beds: Number of Lines Distance between lines SEPARATION DISTANCES TO From Septic Tank Absorption Field Lift Station Holding Tank Sewer Line Ft. Total absorption area Number of trenches Dist. between trenches 648 Ft2 Ft. TANK 0 Septic 0 S.T.E.P. ❑ Holding 0 Other Wel * 50'+' Manufacturer Capacity ANCH TANK 15500 Gal. Surface Water 100'+ 100,+. Material PLASTIC Number of compartments 2 Lot Line 10,+ 10,+ NA Foundation 101+ 101+ LIFT STATION Manufacturer Capacity Remarks * COMM. WATER Gal. Alarm location Electrical installed by Installer MIKE N ANDERSON, P.E. PIPE MATERIAL House to tank Tank to 3034 drainfield 3034 Drainfield 3034 CO/MT3034 Inspector MIKE N ANDERSON, P.E. BENCH MARK (Assumed elevation) 102.5 ft Inspection 1,15/12/2121 SJ12121 dates: 3t° 4'n Location and description � A H L I D ' V' ON-SITE WATER AND WASTEWATER SECTION APPROVAL Conditional Approval: Date e I Stamp r �. ♦ •' r+~gyp g •• I .•495 `� '• ¢�' MICHAEL N. ANDERSCN . 10# 94 9 S g �; • , _� c72 �;;\'_ �0 Fp0r ESSiVV, �U Septic System �/ Approved Date �� ' �d "�' - Note: this approval does not include well permit requirements. (Rev 05/02/18) Permit No. OSP201111 Page 2 of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 Anchorage, Alaska 99519-6650 Telephone: 343-4744 On —Site Wastewater Disposal System and/or Well Inspection Report Legal Description: WOHLFORTH ACRES LOT 1 PID No.: 011-122-94 W— 4e WELL I MARK A B 001 10 18 TC01 15 20 TCO2 20 25 CO2 23 26 CO3 24 27 C04 80 90 C05 55 76 MT1 81 89 MT2 54 75 i / i I SEPTIC \ / j 1 y NEVV 15GG CALLON-PLASM TANK BENCH, TOP OF MH T �- COt 02 � / \"N 0 \ TCO2 %� \ '0 11 /®MJ2 / � MT1�� � I CO, AWWU WATER LINE \ , ASBUILT SCALE: 1 "=50' CO �MT2 C01 TC01 CO CO3 �r1 C04OF C01 T2 .� ••�•...........•... ,D2.4 ,OG OG FINISH GRADE �.�• •� FILTER FABRIC 1.0 FILL . YYY ♦♦ i AV 49 TH 97.8 owax nocx 7 •••••• •/ 98 1,500 GALLON PLASTIC TANK . ....... ..... . . .. SP : MICHAEL N. ANDERSONi i 9 9 ���%% No. CIE 9469 82 Lj •.. ..•� SEPTIC SECTION NO WATER o 82 MAY 2020 �♦• '..� 'yam •".•r p� N.T.S. 111';� C b,CD co S 00*00'00" E 151.65' co co co o �ODql@S JD@] C-) Ln I I z F- I - - - - - - 'o - - - - - - _tip 0 CY) 0 cn 0 cn o ai 0 C14 Cl =3 0, 0 > 0i..1 C: 0 co C; CD m a; L --I-- 00 0 � MqIGS ),UOJ,i OZ w V) 3HO 3H0 - 3H0 --w 09 ,7 O'P,7 ro 0 cc C/') (n _0 0 b,CD co w co co co o Z Ln C-) Ln I I z co 0 CY) cn 0 cn o ai 0 Cl 0, > 0,9(,7 0 QD r-) m L --I-- — — — — — — — — � MqIGS ),UOJ,i OZ 3H0 mrj 3HO 3H0 - 3H0 --w qqw-- 150.29' N 00*19'04" W CD to w co co o C-) AN May 17, 2020 Municipalities of Anchorage Departments of Health and Human Services P.O. Box 196650 Anchorage, Alaska 99519-6650 Fax 249-7847 Re: Septic Permit Legal: WOHLFORTH ACRES LT 1 To Whom it may concern: This is a request for a septic permit on the above referenced lot. Two perc test holes were excavated and found the same material, poorly graded sand (SP) for the entire 18 foot depths. The perc rate was 3 minutes per inch therefore a standard deep trench was designed with a 1500 gallon plastic tank and the standard 20⌦ inch riser. No water was observed in the test hole at the time of excavation or after 7 days. Some of the surrounding lots are serviced by AWWU and some are not. This lot will be serviced by AWWU see the site plan. With the large lots and AWWU water service this new septic permit will not impact any of the neighbors. The lot slopes in the east-west direction with a small valley at the bottom where the septic area is proposed. Sincerely Michael N. Anderson, P.E. 4661 Natrona Anch, Ak 99516 Ph 727-8864 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201111, Rebecca Carroll, 05/22/20 SEPTIC FIELD SECTION DESIGN CRITERIA: 6.0' EFFECTIVE 5 BDRM X 150 = 750 GPD SOILS = 750/1.2 = 625 GPD 625 GA/12 = 52' 2.0' WIDE 52' LONG (1) TRENCH 9.0' DEEP 18 (TH#1) 1.0 SP ORG 1.0'2.0' -9.0 -3.0 MOUND OVER FILTER FABRIC SEWER ROCK ⇥⇤ 3,3( GRADE 1"=200' PROPOSED DRAINAGE FIELD PROPOSED HOUSE SCALE: DJRDRAWN: DATE: WOHLFORTH ACRES, LOT 1 Anchorage, Alaska DEBBIE ANCHETA & ROBERT SUENRAM 5/4/2020 PROPERTY LINE -INGRAM STREET--WEST 80TH AVE- -REKLAS C I R - SEPTIC WELL WELL WELL SEPTIC SEPTIC Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201111, Rebecca Carroll, 05/22/20 1"=50' PROPERTY LINE PROPOSED HOUSE NOTE: SOME LOTS SERVICED BY A.W.W.U. WATER. WOHLFORTH ACRES LOT 2 DRIVE WAY KINCAID ACRES LOT 2C SCALE: DJRDRAWN: DATE: WOHLFORTH ACRES, LOT 1 Anchorage, Alaska DEBBIE ANCHETA & ROBERT SUENRAM 5/4/2020 KINCAID ACRES LOT 2E -INGRAM STREET-WOHLFORTH ACRES LOT 1 CO 1500 GALLON PLASTIC TANK W/ 20" RISER CO MT DCOTCOCO CO TH#2TH#1 AWWU WATER LINE AND KEY BOX SEPTIC AREA SEPTIC AREA 100' WELL RADIUS 0 to 1 % SLOPE0 to 1 % SLOPE10-15 % SLOPE 10-15 % SLOPE 10-15 % SLOPE 10-15 % SLOPE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201111, Rebecca Carroll, 05/22/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201111, Rebecca Carroll, 05/22/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201111, Rebecca Carroll, 05/22/20