HomeMy WebLinkAboutGREENBROOK BLK 2 LT 12EOnsite File Greenbrook Block 2 Lot 12E #017-023-90 Municipality of Anchorage On -Site Water and Wastewater Section - (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP201386 PID Number: 017-023-90 Dwelling: ❑■ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: 9 New ❑ Upgrade Name Colony Builders, Inc. ABSORPTION FIELD A Deep Trench E] Wide Trench E] Bed E] Mound Site Address 13001 Algarin Circle ❑ Other Phone 345-0371 Number of Bedrooms 4 Soil Rating Total depth from original grade 0.45 GPD/SF 12.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4.0 Ft. Gravel depth beneath pipe 8.0 Ft. Subdivision Block Lot Greenbrook 2 12E Fill added above original grade 0.7 Ft. Gravel length 84 Ft. Township Range Section Gravel width 3.0 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 1344 Ft2 1 Ft. Well N/A N/A N/A N/A N/A TANK 9 Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Greer Capacity 1250 Gal. Surface Water >100' >1 00' N/A N/A Material Plastic Number of compartments 2 Lot Line >5' >10' N/A N/A NA Foundation F>1 0' > 10' N/A N/A LIFT STATION Manufacturer Capacity Remarks Tank and line from house to tank are insulated Gal. Alarm location Electrical installed by Installer PIPE MATERIAL House to tank D3034 Tank to D3034 drainfield Red Dog Masonry Drainfield D3034 CO/MTD3034 Inspector J. Millette BENCH MARK (Assumed elevation) 100 ft Inspection 15' 1/27/21 1/28/21 Location and description 2 n 3rtl 1/29/21 41' 1/29/21 Bottom of siding @ point A ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp OF A4, Conditional Approval: Date ,law�P i * '491H rJ . • . • • . . . . • .. . j r -• • Benja • .. •chiller % Septic Sy �� �F� • Approvedstem 1� w Date 3—�d-�j CE 12592 . • �`��� �sisl��Fo . 3/8/21 l�® PROFESS10N4.� Note: this approval does not include well permit requirements. ,7_.. `i U l PERMIT # OSP201386 1N TER SERVICE LINE E-STIM- TED LOCATION >10' SEPARATION FROM ALL COMPONENTS OF THE SEPTIC SYSTEM WAS VERIFIED �T < CONSTRUCTION PID # 017-023-90 1 LOT 12D LOT 12E , :Z 84' LONG x 3'V\ EFFECTIVE ABSORPTION 7 I 5'G ESMT lNGINl ERIN( 4 of Benla in Schiller CE 32 318121 GUY & ANCHOR -ES TO'WgTERE ESAE ESA MENT CEA ""----_. l FCO l 1,250 GALLON f SEPTIC TANK ' w/ 20" MANWAY v1T1 TH3 A JERNATE SITE J�v r® TH2 5' CEA ESMT TEST HOLE LOCATIONS WERE CONFIRMED AT CONSTRUCTION LOT 2 A\ B FCO 1.0 ` 23.3 MH 33.5 731.9 38.2 35.0 2C0 41.4 370 C01 52-7,,45.'5 MT1 58.0 .4 CO2, 134.6 128.8, r ,MT2 ' -, 127.8 122.0 LEGEND CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEAN( FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE PERMIT # OSP201386 0I - 0:E cJV. i 2" INSULATION h— O 98.9 FINISH GRADE 98.2 ORIGINAL GRADE U ENGINEE0.ING PROFILE AS -BUILT (NO SCALE) MM of A4.""h "A Benjatttn Schiller i$ ???ffiiCE 125923/8/21 $����� PROFESSIONP4�� E SOILS LOG AND PERCOLATION TEST N G I N E E R I N G LEGAL DESCRIPTION: GREENBROOK, BLOCK 2, LOT 12E PERFORMED FOR: COLONY BUILDERS DATE: 1/25/21 PROJECT No.: PARCELID#: 017-023-90 TECHNICIAN: J. MILLETTE DEPTH TEST HOLE 2 (feet) 1 2 3 4 5 6 7 8 9 10 11 12 0 14 15 16 17 18 19 20- !lIIllilll 11' OB SLOPE r ' J SILTY SAND SM/ML SAND POCKETS j c � Yi 49 T. 1�-. -- ........... Benja in Schiller Aw la��F�pROFESSiON� .� D BOTTOM OF HOLE COMMENTS: DATE READING WAS GROUND WATER ENCOUNTERED? No NET TIME WATER NET DROP IF YES a WHAT DEPTH? - L (MINUTES) (MINUTES) (INCHES) DEPTH TO WATER AFTER MONITORING: NONE 0 = 1 DATE OF MONITORING: 2/5/21 P 4T-6 _ E D BOTTOM OF HOLE COMMENTS: DATE READING GROSS TIME NET TIME WATER NET DROP (MINUTES) (MINUTES) (INCHES) (INCHES) 1/25/21 1 1:02 4T-6 2 1:32 30 616- 216- 3 1:33 416- 4 2:03 30 516 116 5 2:04 416 6 2:34 30 516 116 PERCOLATION RATE: 21.8 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 10 FT. and 11 FT. SOILS LOG AND PERCOLATION TEST E N G I N E E R I N G LEGAL DESCRIPTION: GREENBROOK, BLOCK 2, LOT 12E PERFORMED FOR: COLONY BUILDERS DATE: 1/25/21 PROJECT No.: PARCELID#: 017-023-90 TECHNICIAN: J. MILLETTE DEPTH TEST HOLE 3 (feet) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 II II IIII 11 OB r SILTY SAND SM/ML SAND POCKETS SLOPE + WAS GROUND WATER ENCOUNTERED? NO IF YES a WHAT DEPTH? - 'r DEPTH TO WATER AFTER MONITORING: NONE DATE OF MONITORING: 2/5/21 BOTTOM OF HOLE COMMENTS: P E DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) 1/25/21 1 3:28 316 2 3:58 30 4 6 116 3 3:59 316 4 4:29 30 416 10 5 4:30 31s 6 5:00 30 41°-6 11s PERCOLATION RATE: 30 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 10 FT. and 11 FT. MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP201386 Work Type: Septic Initial Tax Code Number: 01702390000 Site Legal Address: GREENBROOK BLK 2 LT 12E G:2839 Site Mailing Address: 13001 ALGARIN CIR, Anchorage Owner: DENGEL BARTON & CATALINA Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 10/5/2020 10/5/2021 84622 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: A test hole is required prior to construction of the absorption fields to confirm minimum separations to impermeables and seasonal high groundwater, as well as to confirm the percolation rate of the accepting soil. If results require a design change, construction shall stop pending review and approval of a change order. Please submit results with inspection report (or change order, if required). 4 C0 1' R e_ti i S e S}, 5 n b 0. S e i5� Y' c��2 W� +0 U-y\fec-vn-eC"L)eS. C' Lo y-U'���,�e� , �nS uC. -Io�1 Pv\a Co Cees —,� 1/z��2�z Received By: o Date: Issued By: Date:  32%2; $1&+25$*($.   )$;  -DQXDU\ 02$'HYHORSPHQW6HUYLFHV'HSDUWPHQW 2Q6LWH:DWHU :DVWHZDWHU3URJUDP (OPRUH5RDG $QFKRUDJH$. 6XEMHFW*UHHQEURRN%ORFN/RW(±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¶IURPDOOZHOOVDQG¶IURPVXUIDFHZDWHUDQGPRUHWKDQ¶IURPWKHVHSWLF WDQN 3OHDVHUHIHUWRWKHDWWDFKHGWHVWKROHORJVDQGSODQDQGSURILOHVKHHWVIRUWKHVHSWLFGHVLJQ,IWKLV GHVLJQLVIROORZHGWKHUHZLOOEHQRDGYHUVHLPSDFWVWRDGMDFHQWSURSHUWLHV 6LQFHUHO\ 0LFKDHO($QGHUVRQ3(  \ CO #1 ALTERNATE SITE 1"=50' 84' LONG x 3' WIDE x 8' EFFECTIVE DEPTH ABSORPTION TRENCH 4-BDRM HOME 1,250 GALLON SEPTIC TANK w/20" MANWAY NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM NO EXISTING WELLS - PROPERTIES ARE ON COMMUNITY WATER SYSTEM. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND CO TH3 GREENBROOK, BLOCK 2, LOT 12 E ALGARIN CIRCLE1/26/21 FEET 0 50 100 5' GAS ESMT 10' WATER E A S E M E N T 10' UTILITY EASEMENT5' CEA ESMT GUY & ANCHOR ESMT CEA ESMT TH2 860855850CO MT 2CO SV MH FCO MT WATER SERVICE LINE. EXACT LOCATION TO BE DETERMINED IN THE FIELD. INSURE A MINIMUM 10' SEPARATION FROM ALL COMPONENTS OF THE SEPTIC SYSTEM. CO #1 GREENBROOK, BLOCK 2, LOT 12E DESIGN FACTORS: SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: 31-60 MIN/IN APPLICATION RATE: 0.45 GPD/SF 8' DEEP TRENCH SYSTEM 1,250-GALLON SEPTIC TANK TYPICAL TRENCH SECTION (NO SCALE) 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 3' 6" 6" 3'6" 8' NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY BOTTOM OF TRENCH: 12' BELOW GRADE FLOW LINE ELEVATION: 4' BELOW GRADE TOP OF TRENCH: .5' ABOVE GRADE 600 GPD / 0.45 GPD/SF /8' EFF. DEPTH * 2 SIDES = 83.3 LF TRENCH REQUIRED (188 LF SPECIFIED) 1/25/21 GEOTEXTILE FABRIC CO #1 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 2      PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS:     DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING: IF YES @ WHAT DEPTH? 21.8 6 10 11   1:02 1/25/21 4 0 16 1' OB Professional Engineers Stamp: 1/26/21 30  BOTTOM OF HOLE SILTY SAND SM/ML SAND POCKETS 1 1:32 6 0162 1:33 4 016 30 3 2:03 5 7 164 2:04 4 0 16 30 5 2:34 5 6 166 2 0 16 1 7 16 1 6 16 CO #1 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 3      PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS:     DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING: IF YES @ WHAT DEPTH? 30 6 10 11   3:28 1/25/21 3 0 16 1' OB Professional Engineers Stamp: 1/26/21 30  BOTTOM OF HOLE SILTY SAND SM/ML SAND POCKETS 1 3:58 4 4 162 3:59 3 0 16 30 3 4:29 4 0 164 4:30 3 0 16 30 5 5:00 4 0 166 1 4 16 1 0 16 1 0 16 CO #1 MUNICIPALITY F ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 017-023-90 1. GENERAL INFORMATION Expiration Date: I —Zl — 2- (9 Z-� Complete legal description Greenbrook Sub, Block 2, Lot 12E Location (site address) 13001 Algarin Circle Current property owner(s) Colony Builders, Inc Day phone (907) 345-0371 Mailing address 9420 Vanguard Drive, Unit A, Anchorage, AK 99507 Real estate agent . Day phone 2. TYPE OF DWELLING: i❑ Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ❑ Private Septic 0 Water Storage ❑ Holding Tank ❑ Community Well Q Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 120 (RUSH) Date of Payment 3 ) 0 2 i Receipt Number 019 50b COSA # OSC211097 Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering Phone (907) 522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage, AK 99503 Engineer's Printed Name Benjamin Schiller. Date 03/08/21 i CO 49- 6. DSD SIGNATURE / I System #1 Approved for bedrooms % ' ' BenjamLrvSchiller System #2 Approved for bedrooms �� ��29•. CE 12592 •O o AW Disapproved kPROFESS1oNPAr Conditional approval for bedrooms, with the following stipulations: BY' w- Original Certificate Date:_ —1 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet Legal Description: Greenbrook Sub, Block 2, Lot 12E If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA I log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Comments COMMUNITY WELL B. TANK DATA Age of tank(s) �1 years Tank type/material Septic/Plastic Measured operating fluid level in septic tank NEW 9 Standpipes/foundation cleanout per record drawing Date of pumping Tank installed on 1/28/21 D. ABSORPTION FIELD DATA Deep Trench Which system tested (date installed) 1/29/21 .._9_ALL standpipespresentper record drawing. - Total measured depth from grade 12.7 ft (max) Measured depth to pipe invert from grade 4.7 ft (min) ❑ N/A — pressurized field Q Monitor tubes go to bottom of effective. If not, state depth into effective Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced N/A gallons Comments/Deficiencies: COSA Checklist yellow sheet Parcel ID: 017-023-90 Structure served by this system Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenl ,� ug/L ❑ Arsenic less than MRL (ND) Collected by Date of Sample C. LIFT STATION i2'f�sq ired maintenance completed Age of lift station years Lift station material Comments: Adequacy test date NEW Results ®✓ Pass For 4 Fluid depth prior to test r added gal New dep in Elapsed time min Final fluid depth _ bedrooms in Absorption rate gpd \ Any rejuvenation treatment (past 12 mon If yes, enter date E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) ❑✓ Yes Septic Tank/Lift Station on Lot > 100' r7 Yes if NSA Community Sewer Manhole/Cleanout > 100' NSA Yes No ft [7 Yes if No ft Neighboring Tank > 100' ❑ Yes if No NSA ft Private Sewer/Septic Line > 25' ❑ Yes if No NSA ft Absorption Field on Lot > 100' ❑ Yes if No NSA ft Holding Tank > 100' ❑ Yes if No NSA ft Neighboring Absorption Fields > 100' ✓❑ Yes if No ft NSA Animal Containment > 50' ❑ Yes if No NSA ft ❑ Yes if No ft Community Sewer Main > 75' F-1Yesif No NSA ft Manure/Animal Excreta Storage > 100' F-1Yesif No NSA ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑✓ Yes if No ft Surface Water > 100' P Yes if No ft Property Line > 5' Yes Yes if No ft Wells on Adjacent Lots: ✓® Absorption Field > 5' ❑✓ Yes if No ft Private Wells > 100' ✓❑ Yes if No ft Water Main > 10' ❑✓ Yes if No ft Community Wells > 200' ✓❑ Yes if No ft Water Service Line > 10' Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ❑✓ Yes if No ft If absorption field is under driveway comment below Property Line > 10' ❑✓ Yes if No ft Wells on Adjacent Lots: Water Main > 10' ✓® Yes if No ft Private Wells > 100' ❑✓ Yes if No ft Water Service Line > 10' F,71 Yes if No ft Community Wells > 200' 0 Yes if No ft Surface Water > 100' 0 Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION 1 certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet IF TH • * �0 •' Benja chiller tf �¢)�F� •, . CE 12592 • i�`i�m� 3/8/21 . • ��V.� Y ,0PROFESSOO 0 w J O Q w C-) ff w w p� Q N O \ 0 M w 0 of jE WOWoSoUO- cn O ONAWZ202�zm W 0 z SN Oto O 0 w x Z=1 m V d� V 0 W ZOONZO O f� --+F-O- ZV�0C-) Q N ��x� W i W W QW 0 V [a.fj zwWW�Wp 12 U W OwLa WFO�VOC9 aZ U S W p 0 m 2 m� W Z Z Z N S .. W WO�� w0 V F- W- oc0, cn aa.a � z a -W �Ot3QOSW 00 h O 9— Q a) d- o N p J N04 Z m to o m O ® 02O C7 Z. Z N �WO 3cC9Z M O Ir�$g=3 N N � 4J :c U) N C9 ta' -0 \ 8 \ S� •� G \ \` 1 \ Zz F SN rn fn \ ''----_ w ►� ;d � LOU) 2 ;.I 0 co � U U W ¢ I U) F- N �I o � I .-- I I in 00 I Cd 000 `' N 1 W I W n O I I 1 cc .Z6'O6Z 3uz£.l1090 N - - - - 813 w J O Q w C-) ff w w p� Q N O \ 0 M w 0 of jE WOWoSoUO- cn O ONAWZ202�zm W 0 z SN Oto O 0 w x Z=1 m V d� V 0 W ZOONZO O f� --+F-O- ZV�0C-) Q N ��x� W i W W QW 0 V [a.fj zwWW�Wp 12 U W OwLa WFO�VOC9 aZ U S W p 0 m 2 m� W Z Z Z N S .. W WO�� w0 V F- W- oc0, cn aa.a � z a -W �Ot3QOSW 00 h O 9— Q a) d- o N p J N04 Z m to o m O ® 02O C7 Z. Z N �WO 3cC9Z M O Ir�$g=3 N N � 4J :c U) N C9 ta'