Loading...
HomeMy WebLinkAboutTHE CASCADES BLK 2 LT 4Onsite File The Cascades Block 2 Lot 4 #078-321-10 tKev uwurti b) Municipality of Anchorage On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP201393 PID Number: 078-321-10 Dwelling: ❑E Single Family (SF) ❑ with ADU ❑ Duplex (D) [I Two Single Family Project: ❑E New ❑ Upgrade Name Hultquist Homes ABSORPTION FIELD ❑ Deep Trench 9 Wide Trench ❑ Bed ❑ Mound Site Address 26 R `3 lever C,'�cic ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 522-3204 4 1.0 GPD/SF 4.513.5 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4.0/3.0 Ft. Gravel depth beneath pipe 0.5/0.5 Ft. Subdivision Block Lot The Cascades 2 4 Fill added above original grade 1.3/0.5 Ft. Gravel length 2 @ 60 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field I Tank Line 600 Ft z 2 ' 6 Ft. kA/ell7>1001�1>100' NIA I NIA >25' TANK NSeptic E]S.T.E.P. ❑ Holding E] Other Manufacturer Capacity Greer 1,250 Gal, Surface water >1001 >100' NIA NIA Material Number of compartments Lot Line >5' >10' NIA NIA NA Plastic 2 Foundation>10" 10' ! > 10' NIA N/ALIFT STATION Manufacturer Capacity Remarks No pump log due to artesian well. Jet pump Gal. unit installed in utility room. Alarm location Electrical installed by PIPE MATERIAL Nouse to tank F628Tank to D3034 drainfield Installer Alex Enterprises Drainfield D3034 Co/MTD3034 Inspector J. Millette BENCH MARK (Assumed elevation) 100 ft Inspection 1s' 10/2/20 10/13/20 Location and description dates:3rd 2�a Garage slab. 41'� ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineers Stamp OF Conditional Approval: Date ®�Q„ . • • TH �j Ben)a Schiller Septic System in P 9 . a Approved ,grjld(/ O c ttai Date y �s' . c4/2s/zo • QFC . Note: this approval does not include well permit requirements. tKev uwurti b) EXISTING WELL 1"=50' 2-60' LONG x 5' WIDE x .5' EFFECTIVE DEPTH ABSORPTION TRENCHES 4-BDRM HOME1,250 GALLON SEPTIC TANK w/20" MANWAY CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND TH1 PERMIT # OSP201393 PID # 078-321-10 THE CASCADES, BLOCK 2 LOT 4 A B FCO 25.1 MH 27.6 SV 30.2 A B 2CO 32.3 CO1 42.4 MT1 42.4 CO2 101.3 7.2 14.6 19.0 23.5 24.5 23.7 75.4RIVER CIRCLE12/15/20 FEET 0 50 100 20' DRAINAGE & PUBLIC ACCESS EASEMENT 15' T&E EASEMENT TH2 1 7 7 5 1 7 6 5 1 7 6 0 1 7 5 5 1 7 5 0 1 7 4 5 CO3 CO1 FS CO2 CO4 2CO SV MH FCO ALTERNATE SITE TH3 MT2 MT4 MT3MT1 MT2 101.2 CO3 44.5 MT3 44.8 CO4 101.7 MT4 101.9 FS 58.1 75.1 33.8 34.8 78.8 79.1 38.5 PLAN AS-BUILT PROFILE AS-BUILT (NO SCALE) 99.35 94.3 99.9 104.3FCOMH SV12/15/19 1250 GAL SEPTIC TANK 103.5 FINISH GRADE 60' DRAINFIELD ROCKMT TH#3NO GROUNDWATER 10/12/20 95.7 98.2 COCO89.2 95.7 98.2 102.2 ORIGINAL GRADE MT2CO99.1 MOA APPROVED FILTER SAND PERMIT # OSP201393 PID # 078-321-10 THE CASCADES, BLOCK 2 LOT 4 WEST TRENCH 97.7 97.7 101.7 FINISH GRADE 60' DRAINFIELD ROCKMT TH#3NO GROUNDWATER 10/12/20 95.2 98.2 COCO88.2 95.2 98.2 101.2 ORIGINAL GRADE MTMOA APPROVED FILTER SAND EAST TRENCH 97.7 97.7 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 3      PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS:     DATE OF MONITORING: DEPTH TO WATER AFTER MONITORING: IF YES @ WHAT DEPTH? <1 6 3 4   3:45 10/6 1 2 3 4 5 6 5 - 11 3:49 3:53 3:57 4:01 4:05 OB Professional Engineers Stamp: 12/15/20 3 m 32 s    SANDY GRAVEL GW 6" 6" 6" 6" 6" 6" 3 m 40 s 3 m 35 s 3 m 38 s 3 m 39 s 3 m 41 s 5 - 11 5 - 11 5 - 11 5 - 11 5 - 11 WAS GROUND WATER ENCOUNTERED? Wheaton Water Well, Inc. 1190 N. Wasilla-Fish hook Road Wasilla, AK 99654 (907)376-2041 Name: Hultquist Homes Address: 12570 Old Seward Hwy #204 City: Anchorage State: AK Zip Code: 99515 Well Site: The Cascades Lot/Block: L4B2 Additional: NHN River Circle, Eagle River, AK Well Depth: 79 ft. From: To: Formation: 0 14 silt/gravel/cobble Below Ground: 77 ft. 14 19 wet silt/gravel Above Ground: 2 ft. 19 21 bolder Gal/Min: 21 36 wet clay/gravel 15 gpm 36 42 silt/gravel/cobble Static Level: Artesian 45 bolder42 45 53 silt/gravel/cobble Casing: 79ft. of 6 in. x .25 in. steel" 53 65 gravel/water 65 68 clay/gravel Liner Pipe: N/A 68 81 gravel/water 81 clay Screened: N/A Perforated: N/A Grouted: Yes Grouted to 20' below Depth: surface WATER QUALRY TESTING Develop. Method: Air Ooitfbrm-- Pe Nitrates a Use of Well: Residential Arsedo ND Drilling Method: Rotary Misc: Other: Chlorinated to 50ppm The well was pumped 5' off the bottom with 100% draw down for 2 hours and recovered at 15 gpm . Date Drilled: 10.6.20 Driller: Ben Mattson N 0) m cll J a U 0 J a O Y 0 0 O O o+ V 0 m 0 O L 0 l U m Cc > a U 0L 0 coo a �O i O �! 0 UL I aIm Oa o =•�n.t� 90 E a1 0 JI 0 0 0 C C aoa amNO Me 0 ac WgExm00 I aL= m I EL I 000 Lmvm V L 00 m o w > ` ^ v o m mMCC0` �I mNy0 W �O+O T 0 C o a 0 cc = U a v m c x O ON a m 0 U U C E m> a > o aot o m L r o CE O o I Oc4c 0O— 0 Yat 0 0-6 'I wvo ME= m a �E�mIa c o m > U14F 0 0O OZ 00m x"M mpo'E-E wvVm0L-EN 0 0 t Q3c`m Moc° 9/24/20 Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION - �- Parcel 1. D. 078-321-10 Jj Property owner(s) Hultquist Homes Day phone 522-3204 Mailing address 12570 Old Seward Highway #204 Anchorage, AK 99515 Site address NHN River Circle Eagle River, AK Legal description (Sub'd., Block & Lot) The Cascades, Block 2, Lot 4 Legal description (Township, Range & Section) Lot Size 49,470 Sq. Ft. Number of Bedrooms Four (4) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field ❑X Initial ❑X Single Family (SF) ❑X (w/wo ADU) Septic Tank 7X Upgrade ❑ El (D) Holding Tank ElRenewal ElDuplex Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑X Water Storage ❑ 11 THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) C4 1 Permit/Rush Fees: 9 1 0 '1(a\[ l Q` Q Date of Payment: D Receipt Number: Permit No. Me -201 39 3 Permit App_::- : ._..:c Waiver Fees: Date of Payment: Receipt Number: Waiver No. PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) September 18, 2020 M.O.A. Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Subject: The Cascades. Block 2, Lot 4 – NHN River Circle Septic System Design Dear On-Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property. We are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home and the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system on this lot or adjacent lots. The ground surface on the lot slopes to the southwest at grades approximating 24%. There are slopes greater than 25% within 50 feet downslope of the absorption trenches. The trenches have been designed to meet the steep slope provision of the Municipal Code. The ground surface at the southeast end of the reserve area drops toward the road at a slope greater than 46%. The total drop is 10’ and the surface then flattens to near level. The subsurface soil in the area is clean gravel with a very fast percolation rate. Migration of effluent is not expected to occur as absorption of effluent will be through the bottom of the trench. Ground contours are shown on the site plan indicating the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water and more than 5’ from the septic tank. Please refer to the attached test hole logs and plan and profile sheets for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Michael E. Anderson, PE 9/18/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201393, Rebecca Carroll, 09/24/20 PROPOSED WELL 1"=50' 2-60' LONG x 5' WIDE x .5' EFFECTIVE DEPTH ABSORPTION TRENCHES 4-BDRM HOME 1,250 GALLON SEPTIC TANK w/20" MANWAY NOTE: SLOPES >25% ARE WITHIN 50' OF THE ABSORPTION TRENCHES. THE TRENCHES HAVE BEEN DESIGNED TO MEET THE STEEP SLOPE PROVISION OF THE MUNICIPAL CODE. NO SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND TH1 THE CASCADES, BLOCK 2 LOT 4 RIVER CIRCLE9/18/20 FEET 0 50 100 20' DRAINAGE & PUBLIC ACCESS EASEMENT 15' T&E EASEMENT TH2 1 7 7 0 1 7 7 5 1 7 6 5 1 7 6 0 1 7 5 5 1 7 5 0 1 7 4 5 CO MT MT CO FS CO CO 2CO SV MH FCO ALTERNATE SITE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201393, Rebecca Carroll, 09/24/20 THE CASCADES, BLOCK 2, LOT 4 DESIGN FACTORS: SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: <1 MIN/IN APPLICATION RATE: 1.0 GPD/SF 5' WIDE TRENCH SYSTEM 1,250-GALLON SEPTIC TANK TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY BOTTOM OF TRENCH: 4.5' BELOW GRADE FLOW LINE ELEVATION: 4.0' BELOW GRADE TOP OF TRENCH:0.5' ABOVE GRADE 600 GPD / 1.0 GPD/SF /5' WIDE * 1.0 (RED. FACTOR) = 120 LF TRENCH REQUIRED (120 LF SPECIFIED) 9/17/20 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 5' ORIGINAL GROUND 6" MOA APPROVED SAND2'-0" 3'-6" 6" 6" Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201393, Rebecca Carroll, 09/24/20 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 2 SLOPE SLOPE SITE PLAN DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) The Cascades, block 2 lot 4 8/27/2020 L. Tidwell DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING: IF YES @ WHAT DEPTH? n/a 0.56 6 3 4 078-321-10 CLIENT 10:53 8/27 1 2 3 4 5 6 4 - 10 10:56 10:59 11:02 11:06 11:10 OB Professional Engineers Stamp: 9/17/20 2:06 no None 9/8/20 SANDY GRAVEL GW 6" 4 - 102:36 6" 4 - 102:53 6" 4 - 102:51 6" 4 - 102:57 6" 4 - 103:20 6" ALL MEASUREMENTS TO 1/16". SAND LINER REQUIRED. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201393, Rebecca Carroll, 09/24/20 MUNICIPALITY OF Development Services Department On -Site Water & Wastewater Section -- Parcel I.D. 078-321-10 ANCHORAGE Certificate of On -Site Systems Approval 1. GENERAL INFORMATION Phone: 907-343-7904 Fax: 907-343-7997 Expiration Date: 7/-,? - i IZI Complete legal description The Cascades Sub, Block 2, Lot 4 Location (site address) 2698 River Cir, Eagle River, AK 99577 Current property owner(s) HUItgUISt Homes Day phone 522-3204 Mailing address Real estate agent 12570 Old Seward Highway #204 Anchorage, AK 99515 2. TYPE OF DWELLING: ■❑ Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 Day phone 4. TYPE OF WATER SUPPLY: + L4 -15 TYPE OF WASTEWATER DISPOSAL: Private Well Q Private Septic 0 Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 75 + L4 -15 Waiver Fee $ Date of Payment q1231,20) f Date of Payment Receipt Number 005916 Receipt Number COSA # 0-5 C2, I I I ct -7 Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering Phone (907) 522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage, AK 99503 Engineer's Printed Name Benjamin Schiller. Date 4/21/21 OF gkgslll TH 6. DSD SIGNATURE System #1 Approved for �'� bedrooms % Benja .ne5chiller f System #2 Approved for bedrooms �� ��`���; CE 12592���r� delrFgF:0 ....••P���A Disapproved 11 ROFESSION Conditional approval for bedrooms, with the following stipulations: .,I((ct(((�li�,, trr�uu�al By: 4Original Certificate Date: ,3 2 The Municipality of Anchora Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet COSA Checklist ,Legal. Des-criptlorc The, Ca. 7,!des, Bicyak 2, Lot 4 0 -,`4 21 19 m&f&,1,0hah 1 "-ptic, S�Vslem dim ILII, COSA c-he6o"S"., 'A' _UI S I r Li 1U e, r E, v! I A- WEEILL DATA Imt!'11 11,19 i,�, with for ;mIv.0T1,_. 0,1 Dade >,,, 7 9 Pi f - -ased taw' 79- Sanitary sea; ir funcdrining comEv:ty, khrinns. are pn.7�rly Caring height (above inn :; rid) 24 inw Dale cf f f, voy :e_: , far C 1 WE 2! R. TANK DATA. Age tai lank(ss y�=_ars Tan type,�mal: 7ial SLP'1. ir--11PIaE'1ic Measured operatirp� fluid ._•, el inseptil.-tank New REc.,,,teR_rt:-jLjt pt;,:r record. drmv'�­.l tqf--!-!v I ll: trallation IY2L?G D. ABSORPTION FIELD DATA Shallcnwi Trench 1 '1 4 "AWit '':'start to -steel Oasle instialled) C' 1. [WALL standpipos present per reccrr: drawing TQW! i7!Q`a,',I . .3 1`0 jrl:�Ij Cp,�:J�fjh fN,MI ,T du El N;A - pe- s u r i zee f-- id tdanilor tubes to br,!Lcm effe.cliv-B. If ncz, :-:.jate Im tbFiforn't Na An- TL enic.iii=' AN A - se- rk� istas In r, V W Collerned by Forge Engi-neenno Date c:&s'nw4e 21 �22 C. LIFT STATION riaa-,iertance, carrpleted Ac ys-'sIs G of lift Corr, memr-s: wiur 10 W!A, F;-!��inaf f.';ocz&-,#-.-_quIred sail nfaver cover teld S�-atem prerce�:ed Atsorpti:in ra.:e gpx-_ (Rv ir 0-11 or ju date al: tast) ifs . enter date ro'allcw-�,s '.Mrcdkjo�d K")% 11jollums CcenmeriLsMefidencies: COSA 'chut*10 y-ou.m., E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' Q Yes if No Community Sewer Manhole/Cleanout > 100' Q Yes if No ft [4 Yes if No Neighboring Tank > 100' El Yes if No ft Private Sewer/Septic Line > 25' [E] Yes if No Absorption Field on Lot > 100' E] Yes if No ft Holding Tank > 100' El Yes if No Neighboring Absorption Fields > 100' Community Wells > 200' [j Yes if No Surface Water > 100' Animal Containment > 50' 0 Yes if No El Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' P� Yes if No ft M Yes if No From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' M Yes if No ft Surface Water > 100' ft ft ft ft ft Q Yes if No ft Property Line > 5' Q Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' M Yes if No ft Private Wells > 100' Q Yes if No Water Main > 10' Q Yes if No ft Community Wells > 200' 0 Yes if No Water Service Line > 10' C] Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' M Yes if No ft If absorption field is under driveway comment below Property Line > 10' 0 Yes if No ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells > 100' M Yes if No Water Service Line > 10' Yes if No ft Community Wells > 200' [j Yes if No Surface Water > 100' F Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATIONlow �0 Ad �'�iQ�}� I certify that I have determined through field inspections and review','49 TH of Municipal records that the above systems are in conformance with^ s rf r .�- MOA COSHguidelines in effect on this date. a. ` Beniarr�,r}°�chiller � CE 12592.0 4121/21 COSA Checklist yellow sheet ft ft ft ft