ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP221160 PID Number: 050-315-73
Dwelling: ❑■ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑■ New ❑ Upgrade
Name
RDesign Inc
ABSORPTION FIELD
❑ Deep Trench ❑I■ Wide Trench ❑ Bed ❑ Mound
Site Address
19351 Mount Magnificent Cir
❑ Other
Phone
Number of Bedrooms
Soil Rating
JTotal depth from original grade
5
1.2 GPD/SF
7.6 / 7.6 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
3.5/3.5 Ft.
Gravel depth beneath pipe
4.1 / 4.1 Ft.
Subdivision Block Lot
Roseberry Highlands 1-A
Fill added above original grade
2.1 /3.1 Ft.
Gravel length
39/38 Ft.
Township Range Section
Gravel width
5 Ft.
Beds: Number of Lines
N/A
Distance between lines
N/A Ft.
SEPARATION
DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
770 Ftz
2
8.5 Ft.
Well
>100'
>100'
N/A
N/A
>25'
TANK 9 Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Greer
Capacity
1500 Gal.
Surface Water
>100'
>100'
N/A
N/A
Material
Number of compartments
Lot Line
>5'
>10'
N/A
N/A
NA
Plastic
2
Foundation
>10'
>10'
N/A
N/A
LI TATION
Manufacture
Capacity
Remarks Trenches listed south -north
Gal.
Alarm location
Electned by
Installer
PIPE MATERIAL House to tank D3034. Tank to D3034
drainfield
Brownson Brothers
Drainfield D3034 CO/MTD3034
Inspector L Tidwell
BENCH MARK (Assumed elevation)100 ft
Inspection 15` 9/16/22 2�d 9/17/22
Location and description
3'd 4°i
Top foundation @ B
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
� °F\\alp
k li
Conditional Approval: Date
•'' • .cA,�� }
AW�Q'�.
i TH *fir
'. • e
Septic System
Approved Date 2(0—
BjamenrDaSchiller /
�¢ �F�, •, CE 12592 • *`����
�slF • 8/31/23 •'�C��
. ,
i 11l F� PROFESSI4NP�'.�.�"�
Note: this does
approval not include well permit requirements.
1"=100'
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
PERMIT # OSP221160 PID # 050-315-73
ROSEBERRY HIGHLANDS, LOT 1-A
A B
2CO1 22.3
MH 38.0
SV 42.9
A
B
2CO2 44.8
DV 67.3
CO1 65.0
12.8
36.1
41.6
43.8
70.2
73.2
Sep 07, 2023 FEET
0 100 200
50' BUFFER EASEMENT
EXISTING WELL
w/ 100' RADIUS
ALTERNATE SITE: CAT III SYSTEM w/
15' LONG x 5' WIDE x 4' EFFECTIVE
DEPTH ABSORPTION TRENCH
APP RATE 5 GPD/SF
NEW 1,500 GALLON
SEPTIC TANK w/20"
MANWAY
NEW 38' & 39' LONG x 5' WIDE x 4' EFFECTIVE
DEPTH ABSORPTION TRENCHES
2CO1
CO1
CO2
MT1
5
-
B
D
R
M
H
O
M
E
DV
CO3
TH2
PLAN AS-BUILT
CO2 80.9
MT2
CO3
98.9
CO4 78.0
75.5
93.4
84.5
BM
MH
SV2CO2
CO4
Benjamin Schiller
CE 12592R
E
GISTEREDPROFES S I O N A L E N GINEER
Sep 07, 20238/12/23
MT2
95.590.5
MT1 83.477.8
PROFILE AS-BUILT
(NO SCALE)
97.7
92.0
98.3
102.3FC
O
MH
SV
Benjamin Schiller
CE 12592
R
E
GISTEREDPROFES S I O N A L E N GINEER
Sep 11, 2023
1500 GAL
SEPTIC TANK
97.6 FINISH GRADE
39'
DRAINFIELD ROCK
MT
1
TH
#
2
NO GROUNDWATER 7/29/2022
92.0
CO
2
CO
1
78.5
87.9
92.0
95.5 ORIGINAL GRADE
2C
O
97.6
PERMIT # OSP221160 PID # 050-315-73
ROSEBERRY HIGHLANDS, LOT 1-A
97.0 FINISH GRADE
38'
DRAINFIELD ROCK
MT
2
TH
#
2
NO GROUNDWATER 7/29/2022
90.4
CO
3
CO
4
76.9
86.3
90.4
93.9 ORIGINAL GRADE
TRENCH 1 - SOUTH
TRENCH 2 - NORTH
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On-Site Water & Wastewater Section Fax: 907-343-7997
Pump Installation Log
Well Drilling Permit Number: _______________ Date of Issue: ____-____-____
Parcel Identification Number: ____-____-____
Legal Description Block Lot Property Owner Name & Address:
Pump Installation Date: _____-_____-_____
Pump Intake Depth Below Top of Well Casing: __________ feet
Pump Manufacturer’s Name: ___________________________ Pump
Model: _____________________________________
Pump Size: ____________hp
Pitless Adapter Burial Depth: _________ feet
Pitless Adapter Manufacturer’s Name: _________________________
Pitless Adapter Installer: ____________________________
Well Disinfected Upon Completion?;;<HV No
Method of Disinfection: _____________________________
Comments:
Pump Installer Name: __________________________________
Company: ___________________________________________
Mailing Address: ______________________________________
City: ___________________ State: __________Zip: _________
Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation.
050 315 73
ROSEBERRY HIGHLANDS 1-A
R DESIGN INC
3811 MIDVALE CIRCLE
ANCHORAGE, AK 99507
04 11 2023
390
A.Y. MCDONALD
150C311-8S25
1.50
10
MARTINSON
PELLETS
ANCHORAGE WELL & PUMP SERVICE
7640 KING STREET
ANCHORAGE AK 99518
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP221160
Work Type: Septic Renewal
Tax Code Number: 05031573000
Site Legal Address: ROSEBERRY HIGHLANDS LT 1-A G:0155
Site Mailing Address: 19351 MOUNT MAGNIFICENT CIR, Eagle River
Owner: MICHAEL QUINN CONSTRUCTION INC
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Effective Date:
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
,»ent S
,.
t�eparttnent
6/29/2022
6/29/2023
109865
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
JSpecial Provisions: A test hole is required prior to construction of the absorption field to confirm minimum
separations to impermeables and seasonal high groundwater, as well as to confirm percolation rate of the insitu
soil. Construction may proceed at your own risk prior to the 7 -day groundwater reading. If results require a
design change, construction shall stop pending review and approval of a change order. Please submit results
with the inspection report (or change order, if required).
5
W y» ih rev Sed -�o ko w,e vv�_'v'•, vtp , --lemc Z
Received By: Date:
Issued By: Date:
MUNICIPALITY OF ANCHORAGE
Development Services DepartmentPhone: 907-343-7904
On-Site Water & Wastewater Section UvoFax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 0 50 - 31 J — �3
Property owner(s)
�/ Day phone �0;L2,30 3 V� �7
Mailing address 33?� /// 1
Site address
Legal description (Sub'd., Block & Lot) )I � Wa.� J S U LA
Legal description (Township, Range & Section)
Lot Size Sq. Ft. Number of Bedrooms
APPLICATION IS FOR:
(® all that apply) /
Absorption. Field
Septic Tank
Holding Tank
Privy
Private Well
Water Storage
APPLICATION IS AN:
TYPE OF DWELLING:
Initial
Single Family (SF)
(w/wo ADU)
Upgrade ❑
Duplex (p)
❑
Renewal ❑
Multiple Dwellings
❑
(SF and/or D)
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
I
(Signature of pro rty owner or authorized agent)
Permit/Rush Fees: 1 �( �j Waiver Fees:
Date of Payment: 5 a (o a 0 :� 2 Date of Payment:
Receipt Number: 0 9 Z7 Receipt Number:
Permit No. `� 5 P a �`� (� Q Waiver No.
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc
12.8.20
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 050-315-73
Property owner(s) Highland, LLC Day phone 229-8117
Mailina address 351 E. International Airport Road Anchorage, AK 99503
Site address NHN Mount Magnificent Circle Eagle River, AK
Legal description (Sub'd., Block & Lot) Roseberry Highlands, Lot 1-A
Legal description (Township, Range & Section)
Lot Size 109,865 Sq. Ft. Number of Bedrooms Five (5)
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑X
Initial 0
Single Family (SF)
❑X
(w/wo ADU)
Septic Tank
NX
Upgrade ❑
Duplex (D)
❑
Holding Tank
❑
Renewal ❑
Multiple Dwellings
❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 1� 615 ( GO � l b " 1 �) Waiver Fees:
Date of Payment: 11
Date of Payment:
Receipt Number: d a J 6 Receipt Number:
Permit No. 0Waiver No.
•-��108075 re��
Permit App_ - :• ; .,:c r l �DC T` a r'\
CDIt )
June 20, 2022
UTE
E E R I N G
PO BOX 240773
ANCHORAGE, AK 99524
522-7773
677-7766 (FAX)
FORGECIVIL.COM
MOA Development Services, On -Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: Roseberry Highlands L1 -A
Septic system Change Order
Dear On -Site Services Engineer:
The design of the house and house location have been changed. The previous location of the
proposed septic system had to be adjusted to accommodate the change in layout. The relocation
and adjustment of the absorption trench will not pose any conflicts with the neighboring lots,
existing well location, or other separation distances required.
Sincerely,
r
!j
Benjamin S`Fhiller, PE
,Z'
PO BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
November 14, 2020
M.O.A. Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Subject: Roseberry Highlands, Lot 1-A – NHN Mount Magnificent Circle
Well and Septic System Design
Dear On-Site Services Engineer:
The owner of the above lot intends to construct a new 4-bedroom home on the property. We are
submitting this permit application for the construction of a new well and septic system. The
attached site plan identifies the location of the home and the proposed well and septic location and
alternate site. No conflicts exist between this proposed well and system and any other well or septic
system on this lot or adj acent lots.
The ground surface on the lot slopes to the west at grades in excess of 25%. The absorption trench
has been designed to comply with the steep slope provisions of the Municipal Code. The
distribution line is set at 3.5’ below the surface and no surface disturbance will occur within 50’
down grade from the absorption trench. Ground contours are shown on the site plan indicating the
grade and direction of flow. Stormwater drainage will not impact this septic system. The new
trench will be constructed parallel to the slope as much as possible.
The new system will be a minimum of 100’ from all wells and 100’ from surface water and more
than 5’ from the septic tank. The system has been designed based on the test hole placed during
the subdivision phase of the project. A new test hole will be placed to verify the design
assumptions. Please add a condition to the permit requiring the test hole, water monitoring and
percolation test.
Please refer to the attached test hole logs and plan and profile sheets for the septic design. If this
design is followed, there will be no adverse impacts to adj acent properties.
Sincerely,
Michael E. Anderson, P.E.
11/14/20
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201478, Rebecca Carroll, 12/08/20
ROSEBERRY HIGHLANDS, LOT 1-A Colt�
TRACT
/50 BER UFFEA�SEMi A��JfER NATE
/DOG N 4-
O 01047745-0 / / j15 LONG .
DEPT.
I 1 /
2-3
LONG�x�5
J��EF IONTI
BS � RPTION T
,5001 1 LLON SI
AI�KIW/20" MAI AI'/�1\ITAIAI A
LOT 5
\i
ls'F , GE
�. �ENGINf[RING
• a
"'.....
Ben1 ar?fin Schiller
CB 20292 e
1t�\�� FiiSi6�N—�V-
I
t=
WATER/SERVICE LINE
// /✓
/EXIS/TING WELL MAIN�AIN�10 SEPARATION
/ w/ 100' RADIUS / FROM SEPTIC TANK
II5',TE:�C/ll�lll SYSTEM w/
IW OE��x/4' EFifE�TIVE�
I ABSORPTION/ R NCH / I
jAPP%RATE/5 Gf�D/S` /
WIDE `
E1DEPES
tHNCHES
v,wAY �o S J
60N.
TRACT
RE
\OT 6
NOTE:
SLOPES >25% ARE WITHIN 50�-OF THEIPROPOSED ABSORPTIOI
TRENCH. THE TRENCH HAS BEEN DESIGNED TO MEET THE STEEP
SLOPE PROVISIONS OF THE CODE. NO SURFACE WATER WITHIN 100'
OF THE PROPOSED SEPTIC SYSTEM
ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS
PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC
SYSTEMS.
O 100 200
FEET
1"=100'
LEGEND
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
ROSEBERRY HIGHLANDS, LOT 1-A 'cot 1
(v
R4CT A I TRACT E
/ WATER SERVICE LINE
EXISTING WELL \ MAINTAIN 10' SEPARATION
W/ 10 0' RADIUS \FROM SEPTIC TANK
EASEMENT ALTERNATE SITE: CAT III SYST�M w/
14-047745-0) I15' LONG x 5' WIDE x 4' EFFEgTIVE „
DEPTH ABSORPTION TRENCH
APP RATE 5 GIPD/SF /
2 - 32 LONG x 5' WIDE x 4' \ /�
EFFECTIVE DEPTH /
ABS RPTION TRENCHES \cam
1,500 GALLON SEPTIC c
TANK w/20" MANWAY co G
NIAINTAIN 10' MIN s
FROM FOUNDATION zco
LOT 5 TNORTHRIM `cam, /
ENGINEERING �� i� b3 I
LOTI � N s
P;� of A�gs�li�
fir; cog TH •••ir
Ben arlfin Schiller
Ce , zoz z2 592
•
1,tl�apRaFESS10NP�'��'�
FOUNDATION
DRAIN ENSURE
10' SEPARATION
SROM SEPTIC
LoT16 11
i
EXITING
FOONDATI N
NOTE:
SLOPES >25% ARE WITHIN 50' OF THE PROPOSED ABSORPTION
TRENCH. THE TRENCH HAS BEEN DESIGNED TO MEET THE STEEP
SLOPE PROVISIONS OF THE CODE. NO SURFACE WATER WITHIN 100'
OF THE PROPOSED SEPTIC SYSTEM
ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS
PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC
SYSTEMS.
O 100 200
FEET
1"=100'
LEGEND
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANC
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
ROSEBERRY HIGHLANDS, LOT 1-A CC* 1
DESIGN FACTORS:
750 GPD PEAK FLOW
PERK RATE: 1.0 MIN/IN
APPLICATION RATE: 1.2 GPD/SF
SYSTEM REQUIREMENTS:
5' WIDE SHALLOW TRENCH SYSTEM
1,500 -GALLON SEPTIC TANK
750 GPD / 1.2 GPD/SF /5' WIDE -.5 (RED. FACTOR) = 62.5 LF TRENCH REQUIRED (63 LF SPECIFIED)
BOTTOM OF TRENCH: 7.5' BELOW GRADE
FLOW LINE ELEVATION: 3.5' BELOW GRADE
TOP OF TRENCH: 0.5' ABOVE GRADE
ILE FABRIC
RATED PVC (HOLES DOWN)
-D ROCK
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
F GE
E N G I N E E R I N G
�: ,� TH •,fir
� ..
Benja in Schiller
CE 125926/16/22
�� ��l�a�PROFESSIONP��-Q��
W
0 ,�,e of
tin
Co ®�•. W m.
Er
J�
Aw
FO
Z
w
J
LO
e
2
1
r
v
a`"
oLO
O
Oz
�u
Al
20
—'
e
L O
V i
W
W
L�
Q
o
O N
az
d'
�t
�w
rr
aF
V
�1
w
Cl) Cl) /i
QU
v
�w
a�
�O
o OM
N U
w
D_
��
LL O
w
O
m
�
wLO
ir
OA'
ry
O
r
Ltdlz
z
W
O z
u
z
ED
0o
O
O
00
O
to
ti
O
O
r—
O
10
co
O
O
cm
O
LCA
LO
O
J�
Z
w
J
e
2
v
J
O
20
e
az
�w
rr
aF
QU
�w
a�
r'
GE SOILS LOG AND PERCOLATION TEST
ENGINEERING
LEGAL DESCRIPTION: ROSEBERRY HIGHLANDS LOT I -A
PERFORMED FOR: R DESIGN I N C
DATE: 7/22/22 PARCEL ID#: 050-315-73
DEPTH TEST HOLE 2
(feet)
1
2
READING
I
II
11 OB
NET DROP
INCHES)
(INCHES)
3
'
.
PERC TEST LOCATION
4
416
7i6
5
2
6
10
416
716
316
GM (SILTY SANDY GRAVEL)
7
1:22
10
8
`
• 4
1:33
9
'_•..
716
10
.' •
5
11
.f:•
416
76 3i6
6
1:55
10
12
76
36
13
".
14
• " `••
15
17
18
1
NO WAS WATER ENCOUNTERED?
IF YES @ WHAT DEPTH?
DRY DEPTH TO WATER AFTER MONITORING
7/29/22 DATE OF MONITORING
DATE
READING
START TIME
NET TIME
(MINUTES)
DEPTH To
WATER
NET DROP
INCHES)
(INCHES)
7/25
1
1:00
10
416
7i6
36
2
1:11
10
416
716
316
3
1:22
10
416
76 36
4
1:33
10
4-1
716
316
5
1:44
10
416
76 3i6
6
1:55
10
416
76
36
6" DIAMETER TEST HOLE PRESOAKED PRIOR TO TESTING
PERCOLATION RATE: 2.9 (MIN/INCH)
COMMENTS: USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED
SEE SITE PLAN
TECHNICIAN: J. MILLETTE
6" OF WATER COMPLETELY ABSORBED IN LESS THAN 30 MINUTES
Oc[ 17 08 07','59~
Water Wells
907 688 2759
SULLIVAN WATER WELLS
P.O. BOX ~?0272, CHUGIAK, ALASKA 99567 .TELEPHONE
p,2
OWNER OF LAND;
ADDRESS:
I~ weti ~ed at ~pprov~ ~ ~cat~? ~ N~
~ of ~il~:~ir rot&~ Q cable
~pt~m of we(,:~~ ~
$~at~ W. er Lev~_ t 5 1 ____ f~t
Met~ ¢
W~l Intake Op~ Type: O OP~ e~n¢
Q Scr~; Sta~.. , ~et Stop~.feet
~ Peonies ~d ..... feet 8t~ ....... feel
Depth: ~ ........ feet, to
BORE HQLE DATA.
f DEPTH
'1
ATTEN'IION: I1 is the respor~sibillty of the properly owner to submit a copy of the ,,veil log ~ ~ ~op~ authcri~. Munbipality
¢ Anohocage: ~p~nt o~ He¢lh & H~man Se~lc~ a~¢ ~r~t of E~ircment¢ ~e~i~, MaiSu Bo~gn:
O~d~errt of Env~o~me~tel
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WATER SUPPLY PERMIT
Initial
Date issued: Sep 11, 2008
Expiration Date: Sep 11, 2009
Permit Number: SW080192 Parcel ID: 050-315-22
Legal Description: ROSEBERRY RIDGE ESTATES #1 TRACT A
Design Engineer: 0000 ZZ - NONE NEEDED Site Address: NHN MOUNT MAGNIFICENT CIRCLE
Owner Name: ROSEBERRY RIDGE ESTATES, LLC Lot Size: 649452 SQ. FT.
Owner Address: 10230 RONALD PLACE Total Bedrooms: 0 Permit Bedrooms: 0
EAGLE RIVER, AK 99577-
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
Municipalit3, of Anchorage
Development Services Department
Built lng Sat'~l~, O v 5icm
On-Sh~. ~, at~r aha Wastewat~r Pr~ a~
4700 Br~g~w Str[~[
P.O. Box 1~)5650
~r ~ or,ge. Alaska 99519-6~50
(907) 343-7~4
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 05031522-000 ~/-~7,~_~L~f
Proper~y owrerls) Roseberry Ridge Estates, LLC Da? O~o~e (907) 360-7157
aa~es~ 10230 Ronald Place, Eagle River, AK ~ Coae 99577-8769
Mailing p
Site address Mount Magnificent Circle, Eagle River Zip Code 99577
Legal descripzion (Su~'d., 8lock & Lot) Rosebe~ Ridg~ Es~t~5#l t Tmgt A
Legal description (T~,,'rship. Range & Section) T14N R1W
LO~ Size ......... ,6~9,~.. ~. Et Number of B~r~ms` .,~[A
THIS APPLICATION IS FOR (~ ail that apply): THIS APPLICATION IS AN:
Absorption Field ..~ Iridal
Septic Tank _._: Upgrade [ _i
Holding Tank ~ Renewal ~, ,:~ [7~
Privy i ¢ ~
Private Well ~ This Application is for We~.~3wells
Water Storage ~ required for the Aquifer Test for Preliminary Plat
S-11628-3 Roseberry Ridge Highlands.
I certify that the above information is correc:_ I further cer, ify that. this application is being made for a
Single Family Dwelling and is in acccrdance with applicable Municipai Codes.
PurmiL,'Rusn Fees;
Date 6', Payruer~t:
R~¢uu pt Number:
Dste o~ Paymer~t:
Ruuui2[
0
~Z
LLI
o_ n n
0
· 0
0
J
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 050-315-73
Legal description ROSEBERRY HIGHLANDS LT 1-A
Expiration Date: Z l r Z
Site address 19351 MOUNT MAGNIFICENT CIR Eagle River
Current property owner(s) RDESIGN INC
X The On-site systems) is/are approved for 5 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or advisories:
Original Certificate Date: 9/11/2023
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
COSA Approval_June 2022
MUNICIPALITY OF
Development Services Department
On -Site Water & Wastewater Section
Ro5H
ANCHORAGE
Phone: 907-343-7904
Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 050-315-73
Complete legal description Roseberry Highlands Lot 1-A
Location (site address) 19351 Mount Magnificent Circle, Anchorage, AK 99507
Current property owner(s) RDeslgn Day phone
2. ON-SITE SYSTEMS SIZED FOR 5 BEDROOMS
3. TYPE OF WATER SUPPLY: ❑■ Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units ❑ Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: X Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ❑ Steel ❑■ Plastic ❑ Concrete ❑ Fiberglass
Age <1 yr - See advisory if steel older than 20 years
6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench ❑■ Wide Trench ❑ Seepage Pit
Waiver request for:
Expedited review requested: ❑E
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $ t ZQ
Date of Payment Zai Z 3
COSA# '0SG231 y7
Waiver Fee $
Date of Payment
Waiver #
COSA Application—June 2022
Roseberry Highlands Lot 1-A 050-315-73
9/11/08 400 N/A
44
2.32
18+
9/4/23 Forge Engineering
134 7/31/23
N/A
NEW INSTALLATION
N/A N/A
N/A
NEW INSTALLATION
>
(907) 522-7773
Benjamin Schiller, P.E.8/31/23
Municipality of Anchor
On -Site Water and Wastewater Prog
(907) 343-7904
� - a
N
JAN 2 7 Z020
�Q
U[6 S
CERTIFICATE OF ON-SITE SYSTEMS APPR
Parcel I.D. 050-315-60
• i�, •►
Complete legal description ROSEBERRY HIGHLANDS LOT 2
n
A F ETYA-
Expiration Date: 5' %z= ZO 2-0
Location (site address) 19303 Mount Magnificent Circle, Eagle River
Current Property owner(s) Highland LLC
Day phone
Mailing address 351 E International Airport Rd, Anchorage,
Real Estate Agent Dwell Realty Day phone 907-646-3680
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS:
0
TYPE OF WASTEWATER DISPOSAL:
4. TYPE OF WATER SUPPLY:
Individual]
Individual Well
®
Holding Tank
❑
Individual Water Storage
❑
Community
❑
Community Class _ Well
❑
Public Sewer
❑
Public Water System
❑
WaiverNariance request for: Distance:
Received by:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ 6-zo
Date of Payment / plail2.oao
Receipt Number
COSA# 05c:Z6/oa�
Date:
Waiver Fee $ _
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm ARCTERRA CONSULTING, INC. Phone 696-6111
Address 20441 PTARMIGAN BLVD., EAGLE RIVER, AK 99577
Engineer's Printed Name KENNETH M. DUFFUS Date
Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition
of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface
conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate
during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are
subject to these various and dynamic characteristics and are outside the control of the
evaluator of the well and septic system. Therefore,
ArcTerra can not give any estimate of how long a
system will function satisfactory for current or future
occupants or can ArcTerra guarantee that no unseen i OF A
encroachments, deficiencies or discrepancies exist.
6. DSD IGNATURE
System #1 Approved for bedrooms.
System #2 Approved for bedrooms.
Disapproved.
/1 r
.* q __ _( F '�
1_ KE
INzNE1'7H >i. DG /
1Z� 16 /
`O P FFSS1 ��•
Conditional approval for bedrooms, with the following stipulations:
lllll(ttt((/
rr
CEb V,
B Original Certificate Date:2 • (2' Z47�0
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet 10-10-12.doc
COSA Checklist
Legal Description:
ROSEBERRY HIGHLANDS LOT 2 Parcel ID: 050-315-60
If more than 1 septic system on lot: COSA Checklist # of Structure served by this system 1
A. WELL DATA
Well log is filed with Onsite (or. attached)
Date drilled 9/17/08
Total depth 400 ft
Cased to 44 ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) 24 in.
Date of flow test for COSA 1/16/20
Static water level at beginning of test 140
Comments
ft.
B. TANK DATA
Age of tank(s) years
Tank type/material Se tic/
Measured open -id level in septic tank
t apes/foundation cleanout per record drawing
Date of pumping
D. ABSORPTION FIELD DATA
Which system tested (date installed)
❑ ALL standpipes present per record drawing
Total measured depth from grade max)
Measured depth to pipe invert from e ft (min)
❑ N/A —pressurized field
❑ Monitor tubes go to bo of effective. If not, state
depth into effective
❑ Code -require 11 cover over field
❑ Syste soaked
(Requ' if vacant for greater than 30 days prior to
da test)
Well production at time of test 4.1 gpm
Water storage tank volume gallons
Well disinfected for coliform test? E Yes ❑ Nc
Coliform bacteria is Negative
Nitrate 2'09 mg/L ❑ Nitrate less than MRL (ND)
95
Arsenic 6.ug/L ❑ Arsenic less than MRL (ND)
Collected by ArcTerra
Date of Sample 1/16/20
C. LIFT STATION
❑ Required mainten
Age of lift statin _
Lift statim. aterial
Adequacy test date
mpleted
years
Results ❑ Pass For edrooms
Fluid depth prior to test in
Water added g
New depth
Elapsed time min
Final fluid th in
AbsorpN rate gpd
An ejuvenation treatment (past 12 months)
00"Gallons introduced gallons yes, enter date
Comments/Deficiencies:
COSA Checklist yellow sheet
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
NA
if No
Community Sewer Manhole/Cleanout > 100'
❑ Yes
if No
ft
0 Yes
if No ft
Neighboring Tank > 100' ® Yes
if No
ft
Private Sewer/Septic Line > 25'52] Yes
if No ft
if No
ft
Private Wells > 100'
❑ Yes if No ft
Water Main > 10'
Absorption Field on Lot > 100' F-1YesYes
if No
ft
Holding Tank > 100' ® Yes
if No ft
Neighboring Absorption Fields > 100'
❑ Yes
if No
Animal Containment > 50' ® Yes
if No ft
® Yes
if No
ft
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' ® Yes
if No
ft
0 Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required) NOT INSTALLED
Building Foundations > 10'
❑ Yes
if No
ft
Surface Water > 100'
❑ Yes if No ft
Property Line > 5'
❑ Yes
if No
ft
Wells on Adjacent Lots:
❑ Yes
Absorption Field > 5'
❑ Yes
if No
ft
Private Wells > 100'
❑ Yes if No ft
Water Main > 10'
❑ Yes
if No
ft
Community Wells > 200'
❑ Yes if No ft
Water Service Line > 10'
❑ Yes
if No
ft
If septic tank is under driveway
comment below
From Absorption Field on Lot to: (Please enter distances if less than required) NOT INSTALLED
Building Foundation > 10'
❑ Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
❑ Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'
❑ Yes
if No
ft
Private Wells > 100' ❑ Yes if No ft
Water Service Line > 10'
❑ Yes
if No
ft
Community Wells > 200' ❑ Yes if No ft
Surface Water > 100'
❑ Yes
if No
ft
F. ENGINEER'S COMMENTS
SEPTIC SYSTEM NOT INSTALLED
G. ENGINEER'S CERTIFICATION
1 certify that I have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
COSA Checklist yellow sheet
P.O. Box 670269 Chugiak, AK 99567
P: (907) 688-2759 F: (907) 688-2259
TO: Dea Duffus
JOB LOCATION: 19303 Mount Magnificent Cir
Eagle River, AK 99577
Flow Test Report
Total Depth: 400'
Resting Static: 140'
Max draw down: 386'
Yield at 4.1 GPM
Date: 01/16/20
Tract A
Lot 5
0 10 25 50 100
SCALE: 1 `50'
I
I '
I -
I
/Tract E \
I
I
S 69'35'34"E 351.21'
-i
HOUSE DETAIL
Scale: 1 " = 30'
WELL I /
o I50' BUFFER EASEMENT /
(DOC. No. 2014-047745-0) ` �� o
u r°
co
SEPTIC PIPES
MANHOLE—
SEPTIC PIPES ---,,-
Lot 1—A
109,865 S.F.
\
ti \
N
39.7'. n
LID
SEE HOUSE U'
T
DETAIL cn
CR.
1 7
0
�Y
\ 1
Lot 6
iVERED �
TRY
� I
I
I �
PLOT PLAN _ AS BUILT _K_ SCALE _1= = 50' _ GRID _ MW 0155r Project No. 22-29 LE 5 —r
11500 Daryl Avenue, Anchorage, Alaska 99515--3049
Lang & Associates, inc. (907) 522-6476 Phone opp�0
(907) 522-4625 Fax44C) F q
Professional Land Surveyors ken*longsurvey.com ' � .. .. ,9
jonathan0langsurvey.com DSP s �O
I hereby certify that I have surveyed the following described property:
LOT 1—A, ROSEBERRY HIGHLANDS (PLAT No. 2020-31)
Anchorage Recording District, Alaska, and that the improvements situated thereon are
within the property lines and do not encroach onto the property adjacent thereto, that
no improvements on the property lying adjacent thereto encroach on the surveyed
premises and that there are no roadways, transmission lines or other visible
easements on said property except as indicated hereon.
Dated this the _ �__ Day of ___h_'�`_'� _ _-'— _'' ' at Anchorage, Alaska
It is the responsibility of the owner to determine the existence of any easements,
covenants, or restrictions which do not appear on the recorded subdivision plat.
W •.'
49TH y�
............... .. . ...........
i KENNETH G. LAN o
� ��, •� . g �� C X23 �����
—5202. S�pG
p a Ned
N14�'40F'ESSIONAI- ��
AECC963