ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP211025 PID Number: 041-022-15
Dwelling: M Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: 0 New ❑ Upgrade
Name
Gabriel and Jacenda Fletcher
ABSORPTION FIELD
❑® Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound
❑ Other
Site Address
9730 Copper Drive, Anchorage
Phone
Number of Bedrooms
3
Soil Rating
1.2 GPD/SF
JTotal depth from original grade
11.5 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
4.5 Ft.
Gravel depth beneath pipe
7.0 Ft.
Subdivision Block Lot
Tuxedni Park 3 5
Fill added above original grade
0 Ft.
Gravel length
35 Ft.
Township Range Section
Gravel width
2.5 Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
From
Septic
Tank
Absorption
Field
S
Lift Station
Holding
i Tank
I Sewer
Line
Total absorption area
490 Ft2
Number of trenches
1
Dist. between trenches
Ft.
Well
100'+
I 1001+
NA
I NA
25'+
TANK ❑® Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
GREER
Capacity
1000 Gal.
Surface Water
100'+
I 100'+
NA
( NA
Material
Number of compartments
Lot Line
10'+
10'+
NA
NA
NA
HDPE
2
Foundation
10'+ I
10'+ I
NA
NA
LIFT STATION
Manufacturer
Capacity
Remarks
Gal.
Alarm location
Electrical installed by
Installer
- —
PIPE MATERIAL House to tank 3034 Tank to 3034
drainfield
Drainfield 3034 CO/MT3034
Inspector Pannone Engineering
BENCH MARK (Assumed elevation) 93 It
Inspdection 1-' 4/20/21 Zed 4/21/21
3'd4/23/21 4` 4/26/21
Location and description
Southwest Corner House Trim
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
Conditional Approval: Date
`o v $��
B 9
... �.........
Steven R. annore
814
`�; ?��(•\���
Septic SystemLVIA
Approved`Date
Note: this approval does not include well permit requirements.
DESIGN PARAMETERS
PRIMARY Z RESERVE SEPTIC SYSTEM WATER LINE
NO. BEDROOM: 3(450 gpd)
TANK SIZE: 100Og
PERC RATE: 3 MPI
SOIL RATING: 12 GPD/SF
AREA ROD: 375 SF
SYS. TYPE: DEEP TRENCH 7.0'ED
MIN LENGTH: 26.8 LF
USED:
35LFx2.5'Wx7.0' E.D, 11.5' TD
TOTAL AREA: 490 3F
� ----
� ---- WELL nxmus
----
3S ---- NEW ssPno
ABBREVIATIONS
rx
rssr xnLc
(p)
pnnpnsso
(c)
sx/sT/wc
co
CLEAN OUT NO.
ro
roowoAnnw
cLcAwoor
1111111111131 "1
FLOW SPUTTER
MIT
wow/ron ruec NO.
r/p
TYPICAL |
DE K
INSTALLED 10OOg SEPTIC TAN K (ON ILES)
� ----
� ---- WELL nxmus
----
3S ---- NEW ssPno
ABBREVIATIONS
rx
rssr xnLc
(p)
pnnpnsso
(c)
sx/sT/wc
co
CLEAN OUT NO.
ro
roowoAnnw
cLcAwoor
rs
FLOW SPUTTER
MIT
wow/ron ruec NO.
r/p
TYPICAL |
DE K
INSTALLED 10OOg SEPTIC TAN K (ON ILES)
INSTALLED FOUNDATION CLEAN OUT j� I
STA LLED WELL
AND DOUBLE CLEAN OUT
3BR
HOUSE
SEPTIC AREA
IN'STALLED PRIMARY I DRAIN FIELD (P)
WITH MONITOR TUBE AND CLE
Q,ESE�VE DRAIN FIELD"'
Cl W
SEPTIC AREA
DRIVE
DRIVE
NOTES:
PANNONE ENG SVC, LLC (C.I. 1088)
P.O. BOX 1807 PALMER, AK 99645
0 A4,1"""
REVISIONS
DATE
0601.2022
RECORD DRAWING
PHONE (907) 745-8200 FAX (907) 745-8201
SCALE
TUXEDNI PARK, BLOCK 3, LOT 5
P.I.D. NO
041-022-15
PERMIT NO.
9730 COPPER DRIVE
CE-il4g
211025
SITE PLAN
ANCHORAGE, AK
SHEET
1 OF 2
NOTES:
PANNONE ENG SVC, LLC (Ci 0. 1088)
I
�4•(�G•• ,
IH
•.*
"��eV+Dti f7. ollnowe
CE 8149
'••••
REVISIONS
DATE
06.01.2022
RECORD DRAWING
REV 1: 6/20/22
TUXEDNI PARK, BLOCK 3, LOT 5
GABRIEL & JACENDA FLETCHER
9730 COPPER DRIVE
ANCHORAGE, AK
SCALE NTS
041 5
DRAM, MMM
SEPTIC
LAYOUT
PERMITT 1,10. td0.
OSP211025
SNEER OF 2
Certified Drilling Log
OWNER OF LAND: Gabe Fletcher
ADDRESS: 9730 Copper Drive Anchorage, AK 99507
Bore Hole Data
Depth
From To
LEGAL DESCRIPTION Tuxedni Park Block 3 Lot 5
DATE: 4-16-21
0
2
PERMIT NUMBER: OSP211025 DATE OF ISSUE: 2-8-21
TAX IDENTIFICATION NUMBER 04102215000
Is well located at approved permit location: ®Yes [—]No4
Method of Drilling: Mair rotary ❑cable tool
Depth of Well: 173
Casing Type: Steel Wall thickness ,250 inches
Diameter: 6 inches, depth 173 feet
Liner type
Static Water Level: 40 feet
Recovery Rate 10 ® gpM ❑ gph
Method of Testing Air
Well Intake Opening Type: ® open end ❑open hole
❑ Screened Start feet Stopped
❑ Perforations Start feet Stopped
Grout Type: Bentonite Volume: 50 lbs
Depth: from 2 feet, to 42 feet
Well Disinfected Upon Completion: ®yes ❑ no
Method of Disinfection: Chlorine 50 PPM
Comments:
2
4
29
29
78
78
82
82
130
130
169
169
173
Casing Stickup
Overburden
Silty Sand & Gravel
Tight Silty Sand & Gravel
Silty Sand & Gravel Wet
Tight Silty Sand & Gravel
Silty Sand & Gravel w/ Clay
Sand & Gravel Water
Drillers Name: Cole Sullivan
ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority.
Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation.
Matsu Borough: Department of Environmental Conservation.
Pump Installation Log
Well Drilling Permit Number: SW OSP211025 Date of Issue 2-8-21
Parcel Identification Number: 04102215080
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
(40,
i "
Anow—
Aw
a
Of
= w
Q6�
e
mu
> oj
70v
D
a O
(3)
0- u
0
LL
0 U
0
-T @
Lu Q)
Lli u
�
0-
<
a- (1)
on(13
Lj -0
(D
u 0 C
C: s c .0
u
U
E
Z:D c
i
(n
0
4,�
Lo
Q)
ZO
U Q) C
E-
5' cu
')=3�
0
>
Z,
(--
Ln L
0
t6 Q. f6
0 C D
N C N C
z
<
t� 2-'-
--j
u
>
-0
>
L
<
:3
z
0
(u
C)
<
J--
0
<
0 0 -E
0
� 6
(D
cc:
z w
0
Lj
z c
Z—
—
U M
LD (1) Q)
'n 7E
N0
Lf)
>
:D
c
cr >
u
1)0
Ln
x -E
w ,--• -0 u 0
O
-j
Ln
6j
vm
-I
cr
<
<
cn
Z
E
0
>
0
0
cc
0
r -j
>
W <
b
1-1
0 Q
z rq
U-
rrJi
ON
UJ
Cc5
<
?: co
<
< 2
cr U
0
41
co
0
c) cc
0
Anow—
Aw
Of
= w
Q6�
e
Aw
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Water & Wastewater System Permit
Permit Number: OSP211025
Work Type: WellSeptic Initial
Tax Code Number: 04102215000
Site Legal Address: TUXEDNI PARK BLK 3 LT 5 G:2042
Site Mailing Address: 9730 Copper DR, Anchorage
Owner: FLETCHER GABRIEL & JACENDA
Design Engineer: PANNONE ENGINEERING SERVICES
This permit is for the construction of:
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy
Effective Date:
Expiration Date
Lot Size in Sq Ft:
Total Bedrooms:
cnt
of
f+
v
Department
2/8/2021
2/8/2022
134500
Q Private Well ❑ Water Storage
3
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
1 Special Provisions: A minimum 20 inch manway riser is required to the first compartment of the septic tank.
P - I 'C re- to cad- -J . bJ
`db ' Sep j^rr,-1 4-v ST � L D j'1 0- 16 7- /0 r,`o
�o C�--1, fy. PIn C L 11-2o aa�1
Received By:
Issued By: _ lwl_6� ( ���
Date:
Date:
MUNICIPALITY BRAG
Community Development Departments Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 041-022-15
Property owner(s) Gabriel & Jacenda Fletcher Day phone
Mailing address 1601 Banister Drive, Anchorage, AK 99508
Site address NSN Copper Drive
Legal description (Sub'd., Block & Lot) Tuxedni Park, Block 3, Lot 5
Legal description (Township, Range & Section)
Lot Size 134,500 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(® all that apply)
Absorption Field ❑X Initial ❑X Single Family (SF) ❑X
Septic Tank 19Upgrade El(w/wo ADU)
Holding Tank ❑ Renewal ElDuplex (D) ❑
Multiple Dwellings ❑
Privy ❑ (SF and/or D)
Private Well ❑X
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
G—�
(Signature of property owner or authorized agent)
Permit/Rush Fees: $820 Waiver Fees:
Date of Payment: Z { y /Z. I Date of Payment:
Receipt Number: 012-266- Receipt Number:
Permit No. OSP211025 Waiver No.
Permit App_.;- : . _..:c
MNA
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve(�panengak.com
April 19, 2021
Subject: Tuxedni Park, Block 3, Lot 5
Septic System and Well Permit Request
Design Narrative
This is a design narrative for a permit to install a new septic system and well to be issued for this property. The
proposed systems will serve a proposed three bedroom (3) bedroom house. Currently the lot is undeveloped.
This lot and the surrounding developed lots are or will be served by private wells. Required separation
distances to wells will be maintained.
1. Soils. Two test holes were performed by PES in October of 2020 and April of 2021 and groundwater was
monitored for 7 days. No groundwater was observed. Based on the results of the percolation tests and
overall soils appearance as found by PES an application rate of 1.2 gallon/day/square feet was used for a
conventional wastewater system.
2. Soil Absorption System Design.
a. See Sheet 1 of the design package.
3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The
proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches.
4. Topography: The existing topography generally slopes from the northeast to the southwest in the
area surrounding the septic system at approximately 20%. The slope downhill of the system ranges from 20%-
45% and was field verified. No part of the slope exceeds 45% within 100' of the proposed system.
5. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the
review is complete and that there are no further comments is received from II On -Site Department, the
note will be removed and "Issued for Construction" drawings will be issued.
The proposed installation will not affect the future development of this or the surrounding lots.
Steven R. Pannone, P.E.
Cvlailing: P.O. Box 1807, Palmer, AI( 99645
Telephone: (907) 745-8200 FAX: (907) 745-8201
DESIGN PARAMETERS
PRIMARY / RESERVE SEPTIC SYSTEM
NO. BEDROOM: 3(450 gpd)
TANK SIZE: 10OOg
PERC RATE: 3 MPI
SOIL RATING: 12 GPD/3F
AREA RQD: 375 SF
S,3. TYPE: DEEP TRENCH 7.0'ED
MIN LENGTH: 26.0 LF
|
35LFx2.5\0x7.0' E.D, 12.0' TD
TOTAL AREA: 490 SF
mr MONITOR TUBE NO.
TYP TYPICAL
yV __ WATER LINE
WELL RADIUS
---SS
--- NEW SEPTIC
ABBREVIATIONS
/x
rcsr *oLc
(p)
pnoposco
(c)
sx/snwc
CO
CLEAN our NO.
FC
rouwoAnow
CLEANOUT
rs
rLow spuncn
mr MONITOR TUBE NO.
TYP TYPICAL
INSTALL FOUNDATION CLEAN OUT
AND DOUBLE CLEAN OUT
SEPTIC AREA
PRIMARY/RESERVE DRAIN FIELD (P)
WITH MONITOR TUBE AND CLEAN (ON PILES)
OUT AT EACH END
HOUSE
TH — 2—\`1
SEPTIC AREA
wol
DRI
NOTES:
PANNONE ENG SVC, LLC (CJ. 1088)
P.O. BOX 11807 PALlk.iER, AK 99645
O—A4,q" 1
REVISIONS
DATE
4/19/2021
CHANGE ORDER
TUXEDNI PARK, BLOCK 3, LOT 5
P.I.D. NO
041-022-15
NSN COPPER DRIVE
SITE PLAN
ANCHORAGE, AK
SHEET
1 OF 3
NOTES & SPECIAL PROVISIONS: 1
1. SCOPE AND SPECIFICATIONS:
1.1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MOA COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE
WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.55.
1.2. CONTRACTED WORK WILL BE IN COMPLIANCE WITH MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) DIVISION 10 & DIVISION 20 AS APPROPRIATE,
1.3. SCOPE OF WORK: INSTALL NEW 1000g SEPTIC TANK AND SOIL ABSORPTION SYSTEM.
1.4. GROUNDWATER WAS NOT ENCOUNTERED TO DEPTH OF 18.0 BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF
THE EXCAVATIONS LESS THAN 18.0 BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY.
1.5. STRUCTURES DEPICTED ON THE�TE PLAN ARE BASED UPON ONE OF THE FOLLOWING: CONCEPTUAL PLOT PLAN DEVELOPED BY OWNER: A PLOT PLAN DEVELOPED BY RLS: OR A SURVEY
AS -BUILT.
2. CONSTRUCTION SPECIFICATIONS:
2.1. ALL EXCAVATION DEPTHS ARE ADVISORY. THEY ARE TO BE VERIFIED AND MAY BE MODIFIED BY THE ENGINEER IF ACTUAL FIELD CONDITIONS VARY FROM THOSE USED TO PREPARE THE
DESIGN
2.2. EXCAVATE THE DRAIN FIELD. BOTTOM OF EXCAVATION SHALL BE LEVEL AND SCARIFIED. RECORD ELEVATIONS AT BEGINNING, MIDDLE AND END OF TRENCH BOTTOM. CONSTRUCTION
EQUIPMENT SHALL NOT OPERATE ON THE FLOOR OF THE EXCAVATION. ANY MATERIAL COMPACTED BY THE OPERATION OF THE CONSTRUCTION EQUIPMENT SHALL BE REMOVED AND
REPLACED WITH UNCOMPACTED MATERIAL.
2.3. PLACE THE SEWER ROCK TO THE SPECIFIED DEPTHS. DO NOT CONTAMINATE SEWER ROCK WITH NATIVE MATERIAL OR SPOILS FROM EXCAVATION. LEVEL ROCK SURFACE TO t1" PRIOR TO
INSTALLING THE PERFORATED PIPE.
2.4. ALL PIPE SHALL BE PVC CONFORMING TO ASTM 03034 OR ENGINEER APPROVED EQUAL. MINIMUM SOIL COVER SHALL BE 3 FEET OVER THE PIPE AND 4 FEET OVER THE SEPTIC TANK.
ONE INCH OF INSULATION MAY BE SUBSTITUTED FOR 1 FOOT OF SOIL COVER.
2.5. ALL INSULATION SHALL BE 2" THICK DOW HI -40 INSULBOARD OR ENGINEER APPROVED EQUAL. CENTER INSULBOARD WIDTH OVER SEPTIC TANK OR LINES.
2.6. GEOTEXTILE SHALL BE MIRAFI 140S OR ENGINEER APPROVED EQUAL. LAP ALL JOINTS 2 FEET MINIMUM.
2.7. COVER THE DISTRIBUTION PIPE WITH A MINIMUM OF 2" OF SEWER ROCK AND COVER WITH GEOTEXTILE BEFORE PLACING INSULATION AND BACKFILL.
2.8. MATERIAL USED AS FILL SHALL BE CLEAN AND FREE OF ORGANICS, TRASH AND CONSTRUCTION DEBRIS.
2.9. SLOPE ALL FILL MATERIAL TO DRAIN AT 27 MINIMUM SLOPE AND 3:1 MAXIMUM SLOPE AND IN SUCH A MANNER THAT PONDING AT OR NEAR THE DRAIN FIELD DOES NOT OCCUR. THE
FILL SHALL BE LEFT AT B" HIGHER THAN SHOWN TO ALLOW FOR SETTLEMENT. SEED SURFACE AFTER COMPLETING INSTALLATION AS PER MOA CODE.
2.10. RECORD THE FINISH GROUND ELEVATION OVER THE BEGINNING,. MIDDLE AND END OF SYSTEM.
2.11. MAINTAIN 5' SEPARATION BETWEEN PERCOLATION HOLE AND THE DRAIN FIELD TRENCH.
2.12. EXPOSE, PUMP AND FILL LOG DISPOSAL CRIS OR CONCRETE TANK WITH SOIL TO ABANDON IAW WITH MOA CODE IF NEEDED.
3. CONTRACTOR RESPONSIBILITIES:
3.1. THE CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH THE SITE CONDITIONS AND LOCATIONS OF ALL LOT LINES, EASEMENTS, WELLS (E & P), SEPTIC SYSTEMS (E & P) AND SHALL
MEET MINIMUM SEPARATION DISTANCES OR AS NOTED.
3.2. THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) SHALL HAVE ANY WELL LOCATION AND SEPTIC LOCATION STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE
PLAN WITHIN 30 FEET OF THE PROPOSED SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE WORK.
3.3. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED.
3.4. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES.
3.5. THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING AND LOCATES SHALL BE IN PLACE PRIOR TO NOTIFYING THE
ENGINEER.
3.6. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SITE CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY
THE DESIGN.
3.7. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED -LINE AS -BUILT DRAWINGS TO THE ENGINEER. THE RED -LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL
GROUND ELEVATIONS. PIPE ELEVATIONS, AND TANK ELEVATIONS.
3.6. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF EXCAVATION. TOP OF PIPE WITH CLEAN -OUTS AND MONITOR TUBES INSTALLED,
INSTALLED TANK AND FINAL GRADING.
4. THE CONTRACTOR SHALL SIGN THE FOLLOWING: I CERTIFY THAT ALL WORK WILL BE PERFORMED IN ACCORDANCE WITH THE APPROVED PERMIT, AND ANY AND ALL CHANGE ORDERS, AND
THAT THE AS -BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS CONSTRUCTED.
CONTRACTOR: BY:
TEST HOLE I
'OPSOIL SOILS LOG
)RGANICS
.OAMY SILTY
;AND
SILTY GRAVEL
\ND SAND
WAS GROUND WATER
ENCOUNTERED? N
IF YES, AT WHAT
DEPTH? —NA—'
DEPTH TO WATER AFTER
MONITORING? -DRY
DATE: 28OCT2020
SOIL TEST RESULTS ANALYSIS
• PERCOLATION RATE 5.2 (min/inch)
• PERC HOLE DIAMETER 6"
• TEST RUN BETWEEN 4 FT AND S FT.
COMMENTS: Test hole excavated by WILLOW RIDGE CONSTRUCTION.
PERFORMED BY: PIES. ICERTIFY THATTHISTEST
WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL
GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
DATE PERFORMED: 21OCT2020
READING..
--DATE— NET TIME
WATER
—LEVEL—
READING
NETDROP--(MPI)
RATE
1
21OCT2020
6.57
TUXEDNI PARK, BLOCK 3, LOT 5
GABRIEL & JACENDA FLETCHER.....
NSN COPPER DRIVE
ANCHORAGE, AK
2
25:28 MIN
12.57
6.00'
4.2
3
NOTES SOILS
LOGS''.`.....,..,-
6.57
PERMIT NO.
OSP211025
4
10 MIN
8.90
2.33"
4.3
5
6.57
6
10 MIN
8.49
1.92'
5.2
7
6.57
8
10 MIN
8.48
1.91'
5.2
9
6.57
10
10 LAIN
8.46
1.89'
5.3
11
6.57
12
10 MIN
8.48 1
1.91 1
.2
NOTES:
Pp,NNONE ENG SVC LLC y(C.I. 1088)
PHONE 907 7458200 LPANIER, AK FAX (907)9645-8201
.� """AI
=y�?�� of A4..... .1s,
. =
•, 6Laven R. nnona
e CE -81499 •_•o -i
!Y
I,°RyS1a+a-
REVISIONS
DATE
SCALE19/2021
CHANGE ORDER
TUXEDNI PARK, BLOCK 3, LOT 5
GABRIEL & JACENDA FLETCHER.....
NSN COPPER DRIVE
ANCHORAGE, AK
NTS
P.LD. NO
041-022-15
DRAWN oRM
NOTES SOILS
LOGS''.`.....,..,-
PERMIT NO.
OSP211025
SHEET
2 OF 3
F
TEST HOLE 2
OR TOPSOIL SOILS LOG
1 ORGANICS
2 SM LOAMY SILTY
SAND
3
4
5
6
7
9
10 SAND WITH
SM/GM TRACES Of
11 SILT AND
GRAVEL
12
13 SOIL TEST RESULTS/ANALYSIS
WAS GROUND WATER
14 ENCOUNTERED? N PERCOLATION RATE 3.0 (minlinch)
• PERC HOLE DIAMETER 6"
15 IF YES, AT WHAT TEST RUN BETWEEN 5 FT AND 6 FT.
DEPTH? -NA-'
16
DEPTH TO WATER AFTER
t7 MONITORING? -DRY
18 DATE: 19APR2021
BOH
19 DATE PERFORMED: 12APR2021
COMMENTS: Test hole excavated by GROUNDBREAKERS
CONSTRUCTION.
PERFORMED BY: PES. I CERTIFY THAT THIS TEST
WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL
GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
NOTES: PANNONE ENG SVC LLC (C.I. 1088) .` ` "at, REVISIONS DATE
CHANGE ORDER P.O. BOX 1807 PALMER, AK 996�S '�E OF A��s, 4/19/2021
PHONE (907) 745-8200 FAX (907)- 745-8201 SCALE
NTS
TUXEDNI PARK, BLOCK 3, LOT 5 .1 ..... P.1.D. NO
DRAWN DRM GABRIEL & JACENDA FLETCHER etc R. 041-o22-1s
%,��'.
CE-; 149 PERMIT NO.
NOTES SOILS NSN COPPER'DRIVE"
/ '�y� ��, OSP211025
ANCHORAGE, AK gE,slaul- SHEET
LOGS � ..........
3 OF 3
WATER RATE
READING DATE NET TIME LEVEL NET DROP (MPI)
READING
I 12APR2021 4.71
2 72 MIN 10.71 6.00' 2.0
3 4.71
4 10 "IN 8.96 4.25' 2.4
5 4,71
6 10 MIN 8.50 3.79" 2.6
7 4.71
8 10 ldlN 8.15 3.44" 2.9
9 4,71
10 70 htlN 8.07 3.36' 3.0
t 1 4.7 7
i2 10 MIN
8.05 3.34' 3.0
8.05 3.34' 3.0