Loading...
HomeMy WebLinkAboutT13N R1E SEC 10 N2N2SW4SW4NW4Onsite File T13N R1E Section 10 N2N2 SW4SW4NW4 #050-561-02 �E� / (A J y t— Z v� Municipality of Anchorage On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP211040 PID Number: 050-561-02 Dwelling: A Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: FM_1 New [:1 Upgrade Name KATE POTTEBAUM & MICHAEL "GUS" GUSTAFSONABSORPTION FIELD Site Address ElDeep Trench 0 Wide Trench ❑ Bed E]Mound AJANGO PLACE, EAGLE RIVER, AK ElOther Phone Number of Bedrooms Soil Rating Total depth from original grade 515-468-8405 3 per 1.0 GPD/SF SEE DWG. Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot SEE DWG. Ft. 0.52 Ft. - N2, N2, SW4, SW4, NW4 Fill added above original grade Gravel length Township Range Section SEE DWG. Ft. 90 (2 @ 45) ©Ft. 13N 1E 10 Gravel width Beds: Number of Lines Distance between lines SEPARATION DISTANCES 5 Ft. - - Ft. To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line450 Ft2 2 10+ Ft. Well 100,+ 100'+ _ _ 125+ TANK pQ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity Surface Water 100'+ 100'+ _ _ GREER TANK 1000 Gal. Material Number of compartments Lot Line 5'+ 10'+ - - NA PLASTIC 2 Foundation" _ _ L TION Manufacturer Capacity Remarks *SEPTIC SIZED FOR 3-BEDROOMS Gal. **HJQL4SE -T$"BE-f3UtE-T iN-S-PRJNG/St4A4mER—O -2022, Alarm location Electn f aped by Installer PIPE MATERIAL House to tank **D3034 Tankto D3034 drainfield JR'S EXCAVATION Drainfield D3034 CO/MTD3034 Inspector GEG CONSULTANT, JODY MAUS BENCH MARK (Assumed elevation) 100.00 ft Inspdection 15, 8/9/21 2nd 8/10/21 Location and description 3- 8/12/21 4"8/12-16/A TOP OF MANHOLE (MH1) ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp _Qo6opO Conditional Approval: Date oo��.• e 4P. 1 o ' ...o %J I...........o Septic Syste 0� e+tfey Ggrness: Q� Q �fl,• C -79 3 p Approved Date � � Note: this approva oes not include well permit requirements. #AEcc 44 ofe0 s10( ' (Rev 05/02/18) PERMIT NUMBER: PARCEL ID NUMBER:IOSP211040 RCCRD DRAWING 050-561-02 /`/ + \ C04 132.7 141.6 MT1 141.0 108.4 123.7 CO2 117.1 124.6 RESERVE DRAINFIELD. //'''' 100' WELL RADIUS MT2 118.7 126.4 WILL REQUIRE THE J (APPROX. LOCATION) CO3 156.8 124.5 139.9 USE OF AWWTS NOTE: SWING -TIES TO HOUSE MT3 158.7 126.5 141.9 NEW \ ` APPROXIMATE LOCATION OF \ 100 FOOT WELL RADIUS FOR NEWLY CONSTRUCTED WELL StiFo OF Ar 77777777777 .•4 .' �® GARNESS ENGINEERING GROUP, Ltd i.....: .. .e......•••••.. ....0 _..� CIVIL & ENVIRONMENTAL ENGINEERS •• � 3701 E TUDOR ROAD, SUITE 101 ANCHORAGE, ALASKA 99507 -PHONE (907) 337.6179' WEBSITE: wr .gamesmgineerkVxom •/; .......................... PREPARED FOR: PHONE NUMBER: PAGE NUMBER: f tie• rey A. Garness .' � KATE POTTEBAUM & MICHAEL "GUS" GUSTAFSON 515-468-8405 2 OF 3 ♦ C -7 53 • �c� PROJECTILEGALDESCRIPTION: DRAWN BY: •+/ '. j� j�? %,.•'�� T13N, RIE, SECTION 10; N2, N2, SW4, SW4, NW4 J.L.M. 1��••'......1.. r TYPE OF WORK: DATE: REVISEDI LICENSE®fir®NMr,a�♦�♦+ RECORD DRAWING OF NEW WELL AND SEPTIC SYSTEM 11/29/2022 #AECC884 O + \ C04 132.7 141.6 \ MT4 134.4 143.3 NOTE: SWING -TIES TO HOUSE / CORNERS WERE GENERATED % • + a +` .a • \ IN AUTOCAD USING LAND & ' INSULATED SEWER LINE` ASSOCIATES, INC. AS -BUILT SURVEY DATED 11110!2022. — — •,� UNDER DRIVEWAY WITH 4" OF ` 1 " e ` RIGID INSULATION BY 4 FEET WIDE, CENTERED OVER PIPE NEW 1000 GALLON / " Z a• PER THE CONTRACTOR. GREER PLASTIC . a y, •. SEPTIC TANK / :14 INSTALLED DOUBLE • / A FLOW SPLITTER (FS) 0 • a„ + g f E: a I �. ol I I + FIELDS a I ��� j 1 1 a'' , l` • i I j 4• • rev I I INSTALLED DOUBLE 4 CLEANOUTS (OBL3 & DBL4) ) a• d < s a • i I '"L i I+ �q N a + 8 NEW ' a + ALN WELL • • 100' WELL RADIUS \ ` APPROXIMATE LOCATION OF \ 100 FOOT WELL RADIUS FOR NEWLY CONSTRUCTED WELL StiFo OF Ar 77777777777 .•4 .' �® GARNESS ENGINEERING GROUP, Ltd i.....: .. .e......•••••.. ....0 _..� CIVIL & ENVIRONMENTAL ENGINEERS •• � 3701 E TUDOR ROAD, SUITE 101 ANCHORAGE, ALASKA 99507 -PHONE (907) 337.6179' WEBSITE: wr .gamesmgineerkVxom •/; .......................... PREPARED FOR: PHONE NUMBER: PAGE NUMBER: f tie• rey A. Garness .' � KATE POTTEBAUM & MICHAEL "GUS" GUSTAFSON 515-468-8405 2 OF 3 ♦ C -7 53 • �c� PROJECTILEGALDESCRIPTION: DRAWN BY: •+/ '. j� j�? %,.•'�� T13N, RIE, SECTION 10; N2, N2, SW4, SW4, NW4 J.L.M. 1��••'......1.. r TYPE OF WORK: DATE: REVISEDI LICENSE®fir®NMr,a�♦�♦+ RECORD DRAWING OF NEW WELL AND SEPTIC SYSTEM 11/29/2022 #AECC884 O PERMIT NUMBER: RECORD DRAWING I N G PARCEL NUMBER: OSP211040 050-5611 -02 TOP OF MANHOLE FINAL GRADE = (MH1) = 100.00--X 99.1n-99 Ar- TOP s-, ANK S -TOP OF TIN OT T95.93� I I OUTLLET =95.93 -2" OF INSULATION PER CONTRACTOR INVERT OF PIPE / @ INLET = 95.26—/ INVERT OF PIPE NEW 1000 -GALLON GREER PLASTIC @OUTLET= 95.10 SEPTIC TANK UPPER (EAST) ORIGINAL GRADE @ FINAL GRADE TRENCH HIGHEST POINT = 84.44 = 83.15-84.97 (82.44 ON LOW SIDE) LOWER ORIGINAL GRADE @ Tl C01 C 2 WEST HIGHEST POINT = 81.25 (WEST) (79.25 ON LOW SIDE) FINAL GRADE TRENCH T 2 = 78.90-82.50 h1T3 CO3 T4 C 4 ILTER FABRIC 0.52' OF EFFECTIVE ML r -FILTER FABRIC 2.1.0E INV. OF DIST. 0.52' OF FILTER SAND LINE = 77.06 EFFECTIVE TOP OF FILTER SAND = 76.54 LIMITS OF EXCAVATION = 74.44 2.1' OF INV. OF DIST. TOP OF FILTER FILTER SAND LINE = 70.87 SAND = 70.35 6.1' SEPARATION TO BOTTOM OF TEST HOLE LIMITS OF EXCAVATION = 68.25 RELATIVE ELEVATION OF BOTTOM OF TEST HOLE 91 FOR RELATIVE ELEVATION OF BOTTOM OF TEST HOLE #1 FOR LOWER (WEST) TRENCH = 64.25 (NO GROUNDWATER) UPPER (EAST) TRENCH = 67.44 (NO GROUNDWATER) CESS �l� I EE IIS _ IJ Lid ..�` ...... �. CIVIL &ENVIRONMENTAL ENGINEERS 3701ETUDOR ROAD, SUITE 101'ANCHORAGE, ALASKA 99507' PHONE (907)337.6179'WEBSITE: www.garnessengineering.com•••••••.• ,{.........•.... ..........••.0 PREPARED FOR: PHONE NUMBER: PAGE NUMBER: 0 ey Gayness mr KATE POTTEBAUM & MICHAEL "GUS" GUSTAFSON 515-468-8405 3 OF 3 •���iP ,•. E-7953 ��_�Ar Aw PROJECT/LEGAL DESCRIPTION: DRAWN BY: �, •. 'r Z Ar T13N, R1 E, SECTION 10; N2, N2, SW4, SW4, NW4 J.L.M. ♦ f� p ppp,,,�( • TYPE OF WORK: DATE: LICENSE f � ,Ar"g r��•• RECORD DRAWING OF NEW WELL AND SEPTIC SYSTEM 1/12/2022 #AECC684 Certified Drilling Log � DOC CO dba BILL S. COLE 44 ULLIVAN WATER WELLS f—PP.O. Box 670269, Chugiak, AK 99567 688-2759 OWNER OF LAND: Michael Gustafson & Katherine Pottebaum ADDRESS: LEGAL DESCRIPTION T13N R1E Sec 10 N2N2SW4SW4NW4 DATE: 7-19-21 PERMIT NUMBER: OSP211040 DATE OF ISSUE: 2-23-21 TAX IDENTIFICATION NUMBER 05056102000 Is well located at approved permit location: ®Yes F—]No Method of Drilling: ®air rotary Elcable tool Depth of Well: 144 Casing Type: Steel Wall thickness .250 inches Diameter: 6 inches, depth 144 feet Liner type Static Water Level: 102 feet Recovery Rate 7 ® gpm gph Method of Testing Air Well Intake Opening Type: ® open end Flopen hole ❑ Screened Start feet Stopped ❑ Perforations Start feet Stopped Grout Type: Bentonite Volume: 50 lbs Depth: from 2 feet, to 42 feet Well Disinfected Upon Completion: ®yes ❑ no Method of Disinfection: Chlorine 50 PPM Comments: Bore Hole Data Depth From To 0 2 2 4 4 44 44 49 49 94 94 104 104 119 119 129 129 142 142 144 Casing Stickup Overburden Silty Sand & Gravel w/ Boulders Loose Sand & Gravel Hardpan & Boulders Hardpan & Clay Hardpan Wet Tight Silty Sand & Gravel Water Tight Silty Sand & Gravel Sand & Gravel Water Drillers Name: Cole Sullivan ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. DOC CO dba ILL a COLE 40b"ULLIVAN WATER WELLS WrRO. Box 670269, Chugiak, AK 99567 688-2759 ~m- Installation Log Well Drilling Permit Number: SW OSP211040 Date of Issue 2-23-21 Parcel Identification Number: 05056102080 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. z MANHOLE 0 233.5 00 V SEPTIC PIPES Ark I # ^ I I r- NuuSt DETAIL Scale: 1"-30t 0) t ^Wj, NWjj U 1 Aft. T1a*`Nt 'R1 Et SECTION SEWARD MERIDIAN, ALASKA ....... . 00' PROTECTIVE RADIU'S S 89*51'55"W 667.081 11.8'06.0' SHED w/ 4,0' PORCH .............. FOUND J" REBAR G 81* TOP OF FILL t.0 TOE OF FILL --Z/ F . A PLOT PLAN AS BUILT X SCALE 50GRID SE 1006 Prqject NO. 22-71aZh] 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 La n ASSOCiates, inc. (907) 522-6476 Phone (907) 522-4625 Fox Frofessional Land u r vken*longsurvey.com ()F A� Y jonothon*lDago rvey.com'', .. .';� ............ 4.0'x5.3-* DECK I hereby certify that I hove surveyed the following described property - N1/21, N1/2, SW1/4, SW1/4, NW /4,, SECTION 101 T1 3Nt R1 E, SEWARD MERIDIAN, AK 49TH Anchorage Recording District, Alaska, and that the improvements situated thereon ore ...... within the property lines and do not encroach onto the property adjacent thereto, that (1A no Improvements on the property lying adjacent thereto encroach on the surveyed P1VA . ... , . G promises and that there ore no roadways, transmission lines � 0 KENNETH G or other visible easements on sold property except as indilcoted hereon. N4-52 Doted this the Day of at Anchorage, Alaska It is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plot. AECC963 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage. Alaska 99519-6650 Phone: (907) 3437904 Fax: (907) 343-7997 http:/Iwww.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP211040 Work Type: WellSeptic Initial Tax Code Number: 05056102000 Site Legal Address: T13N R1 E SEC 10 N2N2SW4SW4NW4 G:1006 Site Mailing Address: Owner: GUSTAFSON MICHAEL 50% & Design Engineer: GARNESS ENGINEERING GROUP LTD This permit is for the construction of: d Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date: Expiration Date: npnr \o S c 4; 0.. v. Deparunent Lot Size in Sq Ft: Total Bedrooms: 2/23/2021 2/23/2022 118919 Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing � 2 Received By: - y' 4 Date: �) Issued By: Date: °� /23 add MUNICIPALITY OF ANCHORAGE Development Services Department `� '_ '�� Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 050-561-02 Property owner(s) MICHAEL GUSTAFSON & KATE POTTEBAUM Day phone 515-468-8405 Mailing address 32750 EAGLE RIVER ROAD, EAGLE RIVER, AK 99577 Site address AJANGO PLACE, EAGLE RIVER, AK Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) T13N, RIE, SEC. 10; N2, N2, SW4, SW4, NW4 Lot Size Sq. Ft. Number of Bedrooms 1 (SEPTIC SIZED FOR 3) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field Fx� Initial Fx_1 Single Family (SF) El ADU) Septic Tank El Upgrade El(w/wo Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well 0 Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 'fs g a b Waiver Fees: Date of Payment: 2-101-41 Receipt Number: 07'39-76: Permit No. OS P P 1) 0 � d Date of Payment: Receipt Number: Waiver No. G:\Development Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211040, Rebecca Carroll, 02/23/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211040, Rebecca Carroll, 02/23/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211040, Rebecca Carroll, 02/23/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211040, Rebecca Carroll, 02/23/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211040, Rebecca Carroll, 02/23/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211040, Rebecca Carroll, 02/23/21