HomeMy WebLinkAboutSKY MANOR SOUTH LT 12Onsite File 5k'y Manor South' k vv uoiuc1 ion Municipality of Anchorage On-Site Water and Wastewater Section - (907) 343-7904 Page 1 of 4 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP211109 PID Number: 051-193-52 Dwelling: ❑ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑ Upgrade Name C & T CONSTRUCTION ABSORPTION FIELD ❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound Site Address 14211 HAROLD LOOP, EAGLE RIVER, AK 99577 ❑ Other Phone 240-2020 Number of Bedrooms 6 Soil Rating Total depth from original grade 0.7 GPD/SF SEE DWG. Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade SEE DWG. Ft_ Gravel depth beneath pipe **0.69 / 0.50 Ft. Subdivision Block Lot SKY MANOR SOUTH - 12 Fill added above original grade SEE DWG. Ft. Gravel length 86+ 2 43' EA. Township Range Section Ft. Gravel width 15 Ft. Beds: Number of Lines 3 Distance between lines 5 Ft. - - SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 1290+ Ft 2 2 10Ft. Well COMM. COMM. _ _ 25'+ TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity INFILTRATOR SYSTEMS 1530/1060 Gal. Surface water 100'+ 100'+ _ _ Material Number of compartments Lot Line 10'+ 10+ — — NA PLASTIC Foundation 101+ 1.-0'+ _ _ L TION Manufacturer Capacity Remarks *PER CONTRACTOR Gal. *SOUTH BED / NORTH BED Alarm location Electnc lied by Installer PIPE MATERIAL House to tank D3034Tank to D3034 drainfield GREEN GENERAL CONTRACTING Drainfield D3034 CO/MTD3034 Inspector GEG CONSULTANT, JODY MAUS BENCH MARK (Assumed elevation) 108.06 ft Inspectiones: �5' 8/31/21 2�d 8/31/21 Location and description 31" 9/1/21 4119/2-7/21 TOP OF MANHOLE LID (MH1) ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's St mp Conditional Approval: Date oQboo 0 0 F 00� �0 r 1 . ,rey X arness- QQff Septic System �` Approve Date Z 0 q_2 OZ Cf-7953 p� Note: this approval does not include well permit requirements.#AEccasa4�DOZoV'Vo k vv uoiuc1 ion PERMIT NUMBER: OSP211109 RECORD DRAWING N G PARCEL ID NUMBER: 1 051-193-52 I i -CONTRACTOR INSTALLED KEY I I I BOX AT PROPERTY LINE AND ' ( PERFORMED A MAIN LINE TAP ON THE EXISTING WATER MAIN RESERVE EXISTING SEPTIC DRAINFIELD 1 SYSTEM FOR \ I ---- SITE ADJACENT PROPERTY ___ r ° I NEW WATER LINE. WATER LINE LOCATION PER DAN GREEN o i -_-j 1 WITH GREEN GENERAL L.-------- ---^ CONTRACTING (INSTALLER). \ WATER LINE MARKER INSTALLED AND SEPARATION --��Ta•1CO72 DISTANCE VERIFIED. IrOil1 cog{ icoia NEW DRAINFIELDS op 2 I COSI Mn• J ,I� c f5 FCO 24.4 56.4 / INSTALLED FLOW SPLITTER (FS) , �� 'tib° Ica MH1 39.6 50.0 ST1 47.1 42.7 , !'II {1Cp5 DBL1 49.0 43.5 EXISTING M4� yCO4 DBL2 49.7 44.2 RECORDED I ENCROACHMENT t _ : . -1 �-2p'± _ �� - ST2 51.2 45.3 EASEMENT _...- I CO7 � ST3 46.4 50.1 (FLAGGED BY yV1-1- DBL3 44.2 52.3 SURVEYOR PRIOR' DBL4 43.1 53.4 TO CONSTRUCTION) INSTALLED DBL 1 FS 68.2 80.7 POTENTIAL CO'S (DBL3 & DBL4) MT1 59.5 68.1 200 -FOOT WELL NEW IM -1060 SINGLE COt 59.8 70.3 RADIUS. THIS WELL COMPARTMENT CO2 63.3 74.8 IS BELIEVED 70 BE Na INFILTRATORTANK CO3 67.0 79.0 CURRENTLYr PRIVATE WHICH HAS 100•FOOT -aINSTALLED DBL j 7�-^i CO'S (DBL1 & DBL2)I � � ,r`t MT2 68.9 80.0 MT3 92.3 61.0 C04 .93.0 61.9 WELL RADIUI C05 95.2 66.7 YNE C06 97.5 71.6 f%j W IM -1530 SINGLE FCO COMPARTMENT MT4 97.5 72.4 MT5 86.2 97.5 INFILTRATOR TANK C07 86.4 98.7 B C08 90.8 103.3 J C09 95.4 106.0 MT6 96.7 108.6 MT7 109.4 89.7 ' NEW C010 110.6 90.6 C011 114.2 95.5 6 BEDROOM C012 117.8 100.6 DUPLEX IMT8 117.9 101.7 / NOTE: PIPE LOCATIONS ARE SHOWN PER GEG SHOTS N TAKEN WITH LEICA DISTO / S910 LASER DISTANCE METER. SWING -TIES TO HOUSE CORNERS WERE SCALE: ' -- GENERATED IN AUTOCAD. 1" - - 30' ' •' ' �- ,a. •.. ... .. .:. / •• .DRTVWAY '• �' ' j.� _r \ SSS I J 9 Ltd ENGINEERING SALES CONSULTING ANCHORAGE. AK PHONE (907) 337-6179WEBSITE: w .gamessengineering.mm PREPARED FOR: PHONE NUMBER: PAGE NUMBER: C & T CONSTRUCTION 240-2020 2 OF 4 PROJECT/LEGAL DESCRIPTION: DRAWN BY: SKY MANOR SOUTH S/D; LOT 12 J.L.M. TYPE OF WORK: DATE: RECORD DRAWING OF NEW SEPTIC SYSTEM 2/11/2022 ®� '•'., o f......... ....� ................... ..:.ri <v i.���i.�r.�:..w.�.�.i:.......�...w �Cffrey A. Garness : +� C -7953AW 40 LICENSE ��00®5��.►®®® o #AECC884 PERMIT NUMBER: RECORD DRAWING I N G PARCEL ID NUMBER: OSP211109 051-193-52 TOP OF MANHOLEFINAL GRADE _ LID = 108.06 106.68-106.80 ST1 MH1 TOP OF TANK @ 2" OF INSULATION TOP OF TANK INLET = 103.53 @ (PER CONTRACTOR) OUTLET =103.49 INLET =ML OUTLET INVERT OF PIPE @ INLET =102.90 1530 1-COMPARTMENT INFILTRATOR SEPTIC TANK INVERT OF PIPE @ OUTLET = 102.64 FINAL GRADE = 105.98-106.05 ST3 ST4 TOP OF TANK @ INLET = 103.1 �(PER 2"OF INSULATION TOP OF TANK @ CONTRACTOR) OUTLET = 103.17 INLET OUTLET 1 INVERT OF PIPE @ INLET= 102.52 -' 1060 1-COMPARTMENT INVERT OF PIPE @ INFILTRATOR SEPTIC TANK OUTLET = 102.22 luk __r ... y. , _ �.. _ . �,__, _.. ,. .w I • ®®®4 NE" T �7 �T � T ,rr � • 9 � ��� l� ESS l`� 1�ERING FJ 9 t.....::.....1 .tc .� ...... .............® ENGINEERING SALES CONSULTING ANCHORAGE, AK PHONE (907)337-6179'WEBSITE:www.gamessengineenng.com _ ••••• •• � �/ .......... 0 PREPARED FOR: PHONE NUMBER: PAGE NUMBER: 0 C`1• J•y A• gaam- ESS W s C & T CONSTRUCTION 240-2020 3 OF 4 `®c'� = C 7 53 ° ��r AV PROJECT/LEGAL DESCRIPTION: DRAWN BY: ®4��F Z++�v� •'•��\� SKY MANOR SOUTH S/D; LOT 12 J.L.M. ®O® FD P''pp'tt��/.(.�..•.•.•"'�•`_j'P� �® TYPE OF WORK: DATE: LICENSE 44 ® � ES` O'® w 4 RECORD DRAWING OF NEW SEPTIC SYSTEM 2/11/2022 #AECC884 PERMIT NUMBER: PARCEL ID NUMBER: OSP211109 RECORD D RAW I N G 051-193-52 NORTH BED (FINAL GRADE 1 = 101.08-101.72 FILTER INVERT OF DISTRIBUTION LINES (TYP.) 2.0-2.1 FEET OF MOA = 94.69 APPROVED SAND FILTER `-----15 FEET WIDE -- GRADE 98.90 (HIGH) 97.40 (LOW) MT2 MT4 TH#12 MT5 MT7 FILTER L --TOP OF FILTER SAND = 94.00 BOTTOM OF BED = 91.90-92.00 VATION OF BOTTOM OF TI IS 81.90 TO 83.40 (NO WAT SOUTH BED FINAL GRADE = 101.17-103.04 ORIGINAL GRADE CO2 COI cc,= MT1 100.40 (HIGH) c— MoT3 99.40 (LOW) INVERTOF - ISTRIBUTION LINES (TYP.) 2.0 - 2.1 FEET MINIMUM OF = 96.50 MOA APPROVED SAND FILTER -15 FEET WIDE -TOP OF FILTER SAND = 96.00 BOTTOM OF BED = 93.90-94.00 oorv.®a 4 P,.••• ®® Ar 1 , ®p - .: -- ENGINEERING SALES= -,CONSULTING.- 0 ANCHORAGE, AK PHONE(907)337-6179 WEBSITE: www.gamessengineenngxomd•••••�t •• • •••....... ...... ....... .� PREPARED FOR: PHONE NUMBER: PAGE NUMBER: o Cn 'J g G @SS 4/ a C & T CONSTRUCTION 240-2020 4 OF 4 ♦®�% b CF- 953 �® PROJECT/LEGAL DESCRIPTION: DRAWN BY: ®®® �`�'•.,? , �) y y ���AV SKY MANOR SOUTH SID; LOT 12 J.L.M. ®Fp .. •' �, ®o TYPE OF WORK: DATE: LICENSE 414 t it RECORD DRAWING OF NEW SEPTIC SYSTEM 2/11/2022 #AECC884 'alux's 0 Lo CD 0 CY) Lo 0 G) z00 N -4--J 0 1 @,004001M i i QgoQOpyQ�C, E CL U') c 0 tel. co CC Q 10 r(D, -Y A P, 1 0 C .0 c 0 0 of E m 0 ol Q) 4) 43 L- V) i ¢Over C W :3 C CL cn 4) 0 > 0 0 0 0 c r- ppp46� Q) Q) V) < 0) 0 > 0 C.) 0 7,ut) -�-.� e<v©o < 3"00,90.00S 5;1 'o 0 ,29*V02 Do' a,, -cc - L. 'm 0 .0 c I 0 00- E r M" a) Q-0 Q. 4) Or 0 R 0 -D -0 0 ma Cn C14Cl) to Q0 ,S•6 Lo -,o co C 0 > 0 't 00 0 W.0 0-,2 0c 07 1 .. . . . . . . . 0Q q'E -0 0 .0 -D C14 cn L-. 4) = 0 E L- (D -C a) i c ID ;j 00 Cn j 2-V 0 O-ZL 0 q) (D :T, 0. 0 0 CL 0 LLJ 00 LC) c rn -0 - 0 CL (90 9,E) Ln -g C, 2:ff 4) C '— . cli ul 00 V) (D=—=E > :3 0 2 Los zo Do 0, od C\j i J L -6 9z 69*-eX 3,,00,go.00S E < 0 Q)C) E E -CZ - 0 C) C) U) 0 w I po E -aI k ui C-) to L E; w w V) C14 Lo V) MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PDBox 1S6650 1 4700 Elmore Road Anchorage, Alaska 9ys1g'V85o Phone: -7904 Fax: (SD7)343-,8e/ nnp-ll,wvwmun/.orgmno/m On -Site Wastewater D'sposal System Permit Permit Number: DSP211109 Work Type: Septic Initial Tax Code Number: 05119352000 Site Legal Address: SKY MANOR SOUTH LT 12 G1158 Site Mailing Address: Owner: C&TCONSTRUCTION INC Design Engineer: GARNESSENGINEERING GROUP LTD This permit is for the construction of: 2 Disposal Field 2Septic Tank [] Holding Tank [] Privy Effective Date: Expiration Data: Lot Size in Sq Ft: Total Bedrooms: 4/29/2021 4/29/2022 71 Private Well [] Water Storage All construction shall beinaccordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18/V\C72)and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.G5.Provide notification bycalling (SU7)343-7QU4(24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall boeither: u. Opened and Closed onthe same day, or b. Covered, sealed, and heated huprevent freezing Received By:, Issued By: MUMUPALITY OF ANCHORAGE Development Services Department Phone: 907-33-790 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 051-193-52 Property owner(s) C & T CONSTRUCTION Day phone 240-2020 Mailing address 11404 JESSIE MAE CIRCLE, EAGLE RIVER, AK 99577 Site address SHERMAN STREET, CHUGIAK, AK 99567 Legal description (Sub's., Block & Lot) SKY MANOR SOUTH; LOT 12 Legal description (Township, Range & Section) Lot Size Sq. Ft. Number of Bedrooms 6 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field 0 Initial n Single Family (SF) ❑ Septic Tank 0 Upgrade ❑ (w/wo ADU) (D) Holding Tank ❑ RenewalDuplex ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Waiver Fees: Date of Payment: Z 2( Date of Payment: Receipt Number: Z_G Receipt Number: Permit No. OS PZ( 1109 Waiver No. G:\Development Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211109, Deb Wockenfuss, 04/29/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211109, Deb Wockenfuss, 04/29/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211109, Deb Wockenfuss, 04/29/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211109, Deb Wockenfuss, 04/29/21 Si GARNESS ENGINEERING GROUP, Ltd ' I CIVIL& ENVIRONMENTAL ENGINEERS 3731 E. TUDOR ROAD.SUITE·:, 1· ANCHORAGE. AK 99507· PHONE ( 907) 3378179· FAX( 907) 3383246· WE8SITE. swot gamw3,g,,, n,,) c;:. rn i·· fie0 ·; y ·. arness . iVolSOIL LOG - PERCOLATION TEST I o ; J,CSE: 79 3 T LEGAL DESCRIPTION: TUNDRA JEWEL RANCH: LOT 1 = PROPOSED SKY MANOR PHASE II, LOT 12 O.! s>,e/P...** 1?.1 1( 11.·'...<< tb PERFORMED FOR: C& T CONSTRUCTION DATE: 7/ 28/2015 1;PROF `; 1. DEPTH feet) ----= It ORGANICS TEST HOLE #12 A GG$$ 1 SOIL CLASSIFICATIONS SITE PLAN 2 LOAM ( SM) W/ LARGE q. o , GW =__ORG 3 BOULDERS GP ML 4 744 GM /CL GC 1 OL N'- ie.** . o° O( 01,0„SW MH r SC 1), 1 t ··· SM ,/ / 7/, OH 9 DEPTH TO 1\ 7 +II: 7 GROUNDWATER DATE· fix.,N 8 ·ki. ... DRY 7/ 28/2015 107,41,:, DRY 8/ 5/ 2015 SCALE: t. cam'·' I 1 9 —4040 DRY 10/ 14/ 2015 1· - 100· i`aOV· GP TO SP e- ·DATE READING CLOCK NET TIME WATER LEVEL NET DROP 11 —4 :-, TIME ( MINUTES) READING ( INCHES) 1% 1.. ti. 7/ 28/ 2015 1 6" 12 —' 1· 4;···i,44!1 0„ 6„ 13ifiyy ... 4 1 0"6„ 14 — P·' ' -'· 5 6" 4? :- 6 1 0"6" 15 .gn0,.· 7 6" 8 1 0"6" 16 . 4. i ·.s'i··e· 9 6" 17 ii.6.4. 10 1 0,.6„ 11 6" 18 12 1 0"6" PERCOLATION RATE <1 ( MIN./ INCH) PERC. HOLE DIA. 6 ( INCHES) 19 — TEST RUN BETWEEN 5.5 FT. AND 6. 5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: YES I. NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: ERIK WIDGER COMMENTS: PERCOLATION READINGS ARE WITHIN 1/ 16 OF INCH. PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS RFO MED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: £( ? 1///. I Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211109, Deb Wockenfuss, 04/29/21 a� v N '- 0 U fi O _ p `p OD un co Ll 'G O y is ` 67 10 'Y. A, -6 ■ /� R O p cd to esME=q; O ti0 O .� y •� %p w Oi O00 by ❑ ep cyC Q y I a� V U '� .� o o ic Q LD D r p t3 �� U " C1 r- zu0 N V T ti F.. 0 "yay e'ne -G O y b O(U QCD' rl v N UP)E -p oyi ' cd 4'. O O lV y O Q w Q J Q cn Y Q W .. Q, cOi F R. = z pEf) ca 6. ¢ c O W U h O bA CA Z a s c 2r 00 Q O p a +�' p VS p f/] ❑ y y O C y Gli UN � y O O � •O a�i�47 � � W O eC N O :+ O� v Q CT Z O 0 �� i U W y V Q Of ,y� cd �y U vVi rVii V C b C) hQ a oun �o as A %+. 41 U In Q � a a � a- Od �J G X w w 0 co n COP Q N Q z - Q1 O C O }^ O O C G vi QM O O c� ea p O Cs 00 Q o 0rn N 3 0 4. e •� w 00 w 3 3�too o � ''� z o ° z t 6 w, ; o U U U U U U o [�7 W uz] Gzr.] Gzil 0 co n COP Q N vi Q N C r 12 w CD r o r 0 ti LO rn r O n O N rO V 1 ,n _ v v O w P ° N Ln Ln -S-- 00 V) T v 1^ N O CD r o r 0 ti LO rn r O n O N JH\�1PA"tY0 MUNICIPALITY OF ANCHORAGE On-Site Water&Wastewater Program ); a PO Box 196650 4700 Elmore Road _ '�. `' Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 r • n httpa/www.muni.org/onsite . • \ j Department On-Site Wastewater Disposal System Permit Permit Number: OSP171090 Effective Date: 5/25/2017 Work Type: Septic Initial Expiration Date: 5/25/2018 Tax Code Number: 05119316000 Site Legal Address: TUNDRA JEWEL RANCH LT 1 G:1159 Site Mailing Address: 22827 SHERMAN ST, Chugiak Owner: C &T CONSTRUCTION INC Lot Size in Sq Ft: 307098 Design Engineer: GARNESS ENGINEERING GROUP LTD Total Bedrooms: 6 This permit is for the construction of: EI Disposal Field 0 Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Date: -C./30/7 Issued By: /?.(beir/0 Date: 5/) 5/70 1 7 MUNICIPALITY OF ANCHOA 40111111111611r0 >> Community Development Department 'h ?r 9: 907-343- •4 Development Services Fax: 907- 343- ".7 On-Site Water & Wastewater Program Mayor Dan Sullivan c� On-Site Sewer/Well Permit Application 8 L For A Single Family Dwelling Parcell.D. Property owner(s) C&T CONSTRUCTION Day phone 240-2020 Mailing address 11401 JESSIE MAY CIRCLE, EAGLE RIVER,AK 99567 Site address SHERMAN STREET, CHUGIAK,AK 99567 A;�,,,,._ 1 L1 Legal description (Sub'd, Block& Lot) SKY MANOR SOUTH; LOT 12 T'U,r oL a & . N�.► 1 Legal description (Township, Section & Range) Lot Size Sq.Ft. Number of Bedrooms 6 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING: (®all that apply) Initial ® Single Family(SF) ❑ Absorption Field ® ❑ (w/wo ADU) Septic Tank ® Upgrade Duplex (D) Renewal ❑ Holding Tank I 1 Multiple Dwellings ❑ Privy (SF and/or D) Private Well n Water Storage THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR: N/A Distance: - I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: Si I ` Waiver Fees: Date of Payment: JIGK"t 111 Date of Payment: Receipt Number: O� 0 5l G Receipt Number: Permit No. OSE k CRO Waiver No. (Rev.01/11) N • GARNESS ENGINEERING GROUP, Ltd CIVIL&ENVIRONMENTAL ENGINEERS May 16, 2017 Municipality of Anchorage Development Service Department On-Site Water& Wastewater Program 4700 Elmore Road P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Proposed Septic System for Sky Manor South Subdivision; Lot 12 To whom it may concern: The proposed 6 bedroom duplex is to be served by a community water system (PWSID# AK2218807) and a private septic system. We are proposing that a new 2000 gallon septic tank and a dual bed type drainfield be installed. A test hole was excavated on the property. The primary drainfield will be designed around the 30 foot radius of TH#12. In regards to the reserve site, we are proposing that the bed be rebuilt in the same place in the event of a drainfield failure. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. 4. TOPOGRAPHY: The topography is shown on the attached site plan and design drawing. There are no slope concerns with this installation and there are no cutbanks such as road ditch with 50 feet that will impact the installation of the septic system. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you h' ve any questions, please contact us at 337-6179. Thank you for your assistance. ince -ly, Jeffrey A. i.arness,-P.E., M.S. Presi.-n 3701 E.Tudor Road, Suite 101 * Anchorage,AK 99507-1259 Ph: (907)337-6179 * Fax: (907)338-3246 * Website: www.garnessengineering.com I ‘INt / 1 �i • 1 I I 1 1 I I -- i I uiiit � I L J IL. —MI MI ' ' \ M`- I- --- \ / L. / .,,..ai...._.....zi.._ii..__......__....i / • � \ I i LOT 1; LOT 2 I / LOT 3; LOT 4; I I LOT 5; , LOT 6;/ SKY MANOR SID SKY MANOR S/D ! / SKY MANOR SID SKY MANOR S/D I SKY MANOR S/D 1 SKY MANOFI SID ,___— Ic_•— — — _� - —- — — — 1 .---.—.—.—.-111111.—.—====.7-!—.-----1.—.— �� 1 1 1• 1-i-1-- . I EXISTING I 1 \ iIt I SEPTIC t�,/ `` \ II1 I "SYSTEM I I I 3 `\ , 4 \ \ • 11; LOT 10; LI '• \ \ S •ANOR . • KY M •' •UTH SID j 1\SKY M OR SOUTH S_/D_L. - a �, .. °I. \III I . I \ 9 o �i I I \ • g , ty��� �i I TH#10 -... . I TH#90 • •P• • EPTIC C a I-coi SY M.SEE DESIG Z 1 1-� § iiroolriie I y 1... . • `• TH#9A - • M0 NCf) A P • • • P-OPOSED ) l ' • :ED:s•M � r•• r. -• •SED. orPLEX � : 4ROOM � . l SCALE: / 1 \ 1"=100 / ,/ 00:.„43.0.t.-- \ \ I- / / \ \ ' i 4#4154102idig-'' - ..-- ---i--- -1--- —__ _ -t• ___ yam I I 1 1 11 .; 11 T��_ I �� \ \ `�, / \ / / '1— • \ TUNDRA JEWEL � TUNDRA JEWEL TUNDRA JEWEL TUNDRA JEWEL TUNDRA JEWEL TUNDRA JEWEL RANCH S/D;LOT 101 •. RANCH S/D;LOT 9 RANCH S/D;LOT 8 RANCH S/D;LOT 7 RANCH S/D;LOT 6 RANCH SID;LOT 5 1 ,' I I / I I `\ I ,' 1 I I / I I I \ I / I '4\ 1 I / I I I `\ I ,� I v \ 1 F 1 1 1 44,, 0 F xv.I.,414\k, Air GARNESS ENGINEERING GROUP, Ltd ..: jip '� ���* 10 CIVIL&ENVIRONMENTAL ENGINEERS . , I•Ir' t • • 3701 E.TUDOR ROAD,SUITE 101'ANCHORAGE,AK 99507'PHONE(907)337-6179'FAX(907)338-3246'WEBSITE:www.gamessengineerinp"can • . PREPARED FOR: PHONE NUMBER: PAGE NUMBER: to I A. a arness / C&T CONSTRUCTION 240-2020 1 OF 3 ♦• , C '5 • J PROJECT/LEGAL DESCRIPTION: DRAWN BY: ••♦ V. 1 1''••• • SKY MANOR SOUTH S/D; LOT 12 J.L.M. ♦• pRoF ••• , .4p TYPE OF WORK: DATE: REVISED LICENSE III E�1,* 44 SITE PLAN FOR PROPOSED SEPTIC SYSTEM 5/24/2017 #AECC884 �s��i ;% \ // ' MOTE:THE CONTRACTOR I EXISTING SEPTIC SYSTEM 1 ,/' //' SHALL HAVE THE LOT LINES, I FOR ADJACENT PROPERTY / / SEWER EASEMENT,AND ALL I I // �/ 1 /' THE WELL RADII FLAGGED/ I I // ,/ //' STAKED BY A REGISTERED \ , PROPOSED / / LAND SURVEYOR PRIOR TO I I _�/ WATER LINE ' {WATER PROPOSED �'ANY CONSTRUCTION. I / ^ , LINE //— ' L— /' SEWER EASEMENT /' / // % \ ' /' /' / ,' PROPOSED DRAINFIELDS '/ /' // (SEE DETAIL DRAWING, r /// ` O►\^^' PAGE 3OF3) // / 7\\ --47 /// /// I ../// ,// .. M1 GO / V" / // // // ��'� �A(A' ,/ NOTE:RESERVE SITE SHALL // \ \J • /// �'' // \Go �,/ BE THE REBUILDING OF THE �P• EXISTING DRAINFIELD.. . t / / , 44 (4 ...- e .. .F'' __ -- / ..- �'/ //INSTALL FLOW M -' \Go ,' /' //,/' f►/ _^✓� SPLITTER M 'ice' •. . I �/ ►—I �'�'D, I -'' \ „� �\ -5-- ‘...)5. '//iii.' F►-10'+ / ' 1 �. I--- ► I „, I 1,-' . \US I i'' \\'.i.'' 1 '' i'/ 150 W' __LL \.,' ' �' „� �' // T �• INSTALL DOUBLE CLEANOUTS J ... 1 ,' . . ' L �' .0 .' SC // ___►►r ►^1�-' I Co PROPOSED 2000 ',/ ���' G�LLON SEPTIC TANK1............ 1 �.' 1"=30' / -' t .... I /' 'I ' '/�, '/. I /� //-. / 0" -� . '. / 1 ..--- ..--• /' ..- -- / _,-) // , '// '/' // / / / 4'. FCO '. '_, I:::IIh I .., ,,� ` a' i r ,. ' / — J I DESIGN CRITERIA: / I _-, �' �' �' NUMBER OF BEDROOMS: 6(DUPLEX) ,/ / I.' \\,.�' ���' PROPOSED. ' i' GALLONS PER DAY(GPD): 900 // / �I. 6 BEDROOM /,'- PERCOLATION RATE'S: <1 MINUTE/INCH / / �. DUPLEX �� PROPOSED APP.RATE: 0.7 GPD/SQ.FT. i i� '��/' I /�' '� MINIMUM DRAINFIELD SO.FT.: 1286 = NNMYYM '.' ''��' ''�� DRAINFIELD DESIGN: GEG,Ltd.HAS A PAGE SPECIFICATION �� LETTER THAT PER AINS TO THIS DESIGN.TO /' .' OBTAIN A COPY F THE LETTER CONTACT .'/ ' MAXIMUM DEPTH: 10 FEET©HIGHEST POINT GEG.BY PROLE DING FORWARD WITH THIS /' ,�O' .'� WIDTH: 15 FEET /' INSTALLATION,T E ENGINEER,WELL DRILLER,/' / .,/'_ • . ,------- CONTRACTOR LENGTH: 86 FEET(2(i$43 FEET LONG EACH) CONTRACTOR D PROPERTY OWNER AGREE .r'. ' • ,• c ••. M.O.A.APPROVED SAND FILTER: 2 FEET • EFFECTIVE: 0.5 FEET THAT THEY HAVE READ THESE , •'' ;••�.�' ..• i SPECIFICATIONS AND AGREE TO ACCEPT THE ,./ ..: j(, REDUCTION FACTOR: N/A TERMS AND CONDITIONS OUTLINED. ' ,./�: • DRIV�QYAI(•.;. '� •' ,- ACTUAL SQ.FT.: 1290 ^, ..•'`\\\\\i, :4. >\c * .. ,,,♦j1 GARNESS ENGINEERING GROUP Ltd *:� 4' :.`** CIVIL&ENVIRONMENTAL ENGINEERS I • 0 3701 E.TUDOR ROAD,SUITE 101'ANCHORAGE,AK 99507'PHONE(907)337.6179'FAX(907)338-3246'WEBSITE:w+iw.gamessengireering.am I• •• PREPARED FOR: PHONE NUMBER: PAGE NUMBER: 0 J e '.G:mess • C &T CONSTRUCTION 240-2020 2 OF 3 •• 661 Y C 7• -= PROJECT/LEGAL DESCRIPTION: DRAWN BY: . . ♦ ,.••,``3y P,:.•0 TYPE OF WORK: DATE: REVISED LICENSE TYPE E� ♦ 4• DESIGN OF PROPOSED SEPTIC SYSTEM _ 5/24/2017 #AECC884 ����� J I 2I—} r OMT MTO I 2.15' 0 "SOLID PIPE O 4"PERFORATED PIPE CO 15 CO fO Q MT MTO 2.5' 1ILI 39 FEET LONG -1 43 FEET LONG - 10' INSTALL FLOW SPLITTER r 2 Q MT MTO ' 2.5 0 "SOLID PIPE 4"PERFORATED PIPE FROM SEPTIC TANK —.-- 0 1 ' CO CO iO Q MT MTO 2.5 L I I- 39 FEET LONG I } I_ -43 FEET LONG FINAL GRADE FINAL GRADE ORIGINAL GRADE ORIGINAL MT CO CO CO MT GRAD= 2j E MT CO CO CO MT a_rIP — e— THc i I- 10'DEEP MAX. 10'DEEP MAX. AT ANY POINT AT ANY POINT i'i FILTER > FILTER > FABRIC O 0 FABRIC O U I o LL r7 U_ w LLI P..::.•................. •• •..... INVERT OF ,• ..�,,. .4v+ _ .. ".< :.J.F. 6�'?p''sf"��� DISTRIBUTION .4.4.e.,•''2F �,' ..�,+ -i } , INVERT OF �'�+�'°'` yo'�`"''_a is -n,F.. 2 FEET OF MOA FILTER APPROVED � r7..1Mc; ...t 4,—ii,-...i„...7::,, �'C:. .b.� ,,�,p Mf LINES (TYPJ 4�r Y SAND FILTER, iyJ��}J° f„ P DISTRIBUTION ''''.4...2 FEET OF MOA APPROVE v •' ?..P.•t: ' . • LINES (TYP.) �ti�ih r'V� SAND FILTER .4, 7i6. r 1 '�-„ p'.+-"�r• t�''� y h+.... �f3. 1 fit' NI '1'2Ja`! A`► 12 ..►4 n�_'� YCS. T"r141 I- 15 FEET WIDE 1 15 FEET WIDE -10 -i--- I TOP OF SAND TOP OF SAND BOTTOM OF BED BOTTOM OF BED TEST HOLE DEPTH IS 17 FEET (NO WATER) ..���\ ,11 • ..v;............ ,.S �1 GARNESS ENGINEERING GROUP, Ltd : .. ..;.i • • CIVIL&ENVIRONMENTAL ENGINEERS r I • 3701 E.TUDOR ROAD.SUITE 101'ANCHORAGE,AK 99507'PHONE(9071 337-6179-FAX(907) 338-3248-WEBSITE:www.gemesalnpineee g mn 0 ;— 11..i• 4 PREPARED FOR: PHONE NUMBER: PAGE NUMBER: 0 cn.. - '.Ga '-SS : w a C&T CONSTRUCTION 240-2020 3 OF 3 1►•,,• 795 '��./ LEGAL DESCRIPTION: DRAWN BY: • SKY MANOR SOUTH SUBDIVISION; LOT 12 J.L.M. ��j'QF��''• � ' ,,���,\� ��• TYPE OF WORK: DATE: LICEN�E,I.�rUFESS\ 4- DETAIL DRAWING OF PROPOSED DRAINFIELD 5/16/2017 #AIECC884 c voisst la ii GARNESS ENGINEERING GROUP, Ltd A 91 1J\ CIVIL& ENVIRONMENTAL ENGINEERS - •)� f • • 3701 E.TUDOR ROAD.SUITE 101•ANCHORAGE.AK 99507•PHONE(907) 337-6179•FAX(907) 338-3246•WEBSITE:www yamoaaonynomky corn SOIL LOG - PERCOLATION TEST #��':•aa J: • A. arriess cLLJ: # j.) •� CE- 953 ..i ii LEGAL DESCRIPTION: TUNDRA JEWEL RANCH;LOT 1 =PROPOSED SKY MANOR PHASE II,LOT 12 4.<4‘44...'� .� r <e•- ..co PERFORMED FOR: C&T CONSTRUCTION DATE: 7/28/2015 �4 �'ROFESSO\w' 4-• DEPTH - 1111II%IWO"' (feet) -- - ORGANICS TEST HOLE #12 � SOIL CLASSIFICATIONS SITE PLAN 2LOAM (SM) •• W/ LARGE ' d,:=:o-'. GW -_ __ ORG •• ` ` +f GP 1~ ML •3 • BOULDERS �r..� GM I �GC � CL ---,,r�y�▪ �iy oa o 06 Z�;f:e! O?°0°ecy.coy0°0, SW 1)) MH �Q 5 if • SM / / ,, OH �O ...-,-....‘o- '+'. k., SC d` 1..A.,.• .,.,:,:: e 7 DEPTH TO DATE Q' I▪ V! GROUNDWATER ((���4 N 8 ;Nyf DRY 7/28/2015 -eY �'� DRY 8/5/2015 SCALE: 9 —f:iiiir'iDRY 10/14/2015 1.=too' 10 —ha* , CLOCK NET TIME WATER LEVEL NET DROP •�-�+�' DATE READING 11 —/.740.44,4. TIME (MINUTES) READING (INCHES) ±i. 7/28/2015 1 - - 6" - 12 ,, `t' 2 - <1 0" 6" 13 . 3 - 6" Ile*`Y ,—1 4 - <1 0" 6" • 14 — .▪4N4;044:4 5 6" ;fie`Vi: 6 <1 0" 6" 15 r'ii44.0. 7 - - 6" 16 , •! 8 <1 0" 6" 11 _ - 6" 18 y 12 - <1 0., 6" PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 — TEST RUN BETWEEN 5.5 FT. AND 6.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES El NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: ERIK WIDGER COMMENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. PERFORMED BY GEG, Ltd. I,JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PEREOPME? IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: (.7,/y if i ®Municipality of Anchorage o On -Site Water and Wastewater Program T (907) 343-7904 5'A � T -Y Certificate of On -Site Systems Approval Parcel I.D. 051-193-52 1. GENERAL INFORMATION: Complete legal description SKY MANOR SOUTH, LOT 12 Expiration Date: l — ( ` 2_©2- Location (site address) 22913 SHERMAN STREET CHUCIAK AK 99567 Current Property owner(s) C & T CONSTRUCTION Day phone 907-240-2020 Mailing address 14211 HAROLD LOOP EAGLE RIVER, AK 99577 Real Estate Agent. _ 2. TYPE OF DWELLING: ❑ Single Family (w/wo ADU) ® Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 6 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual Individual Water Storage ❑ Holding Tank ❑ Community Class A Well ® Community ❑ Public Water System ❑ Public Sewer ❑ Waiver/Variance request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 2 Date of Payment Receipt Number D? 5 2 3 6 COSA# 0SC22 I QIJ5 Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system d OF A v�04 in accordance with the guidelines and regulations established by the Municipality of Anchorage and 4:__7 , . • Q �s�C�o industry practices. The reported results describe the condition of the system/s on the date/s of the •' evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may that identified during Op exist were not the evaluation. The operational life of all wells * `t and septic systems depend upon a variety of variables, including but not limited to, soil conditions, • • • • . • • • • • • groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and O are outside the control of GEG. Satisfactory test results do not guarantee future performance of the - system/s; therefore, GEG Qn •J f r A. - S." makes no warranty (express or implied) regarding the future performance 0'.',-V CE— 7 53 0� the well or septic system. GEG makes no representation whether an alternative well or septic system 9 c OQ can be installed on the property in the event either of the current systems fail to perform adequately in future. The �Qf11� �s''.'•z. Pa the content of this report is for the sole benefit of the person/party that retained GEG to p,O { e s s"000\ perform the evaluation. Reliance upon the information provided in this report by any other person or party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. #ArT7,884 6. DSD SIGNATURE System #1 Approved for Cbedrooms �``�y OF ANcf% System #2 Approved for bedrooms��' p ool- Disapproved ok P� Conditional approval for bedrooms, with the followingApul 00 O 12 Original Certificate Date: 2 ' 1 _ 27 The Municipality of Anchorage Develdpment Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist 4(_Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet_1410-12.doe COSA Checklist Legal Description: SKY MANOR SOUTH; LOT 12 Parcel ID: 051-193-52 If more than 1 septic system on lot: COSA Checklist # 1 of 1 Structure served by this system 1 . ELL DATA 1. SERVED BY A COMMUNITY WATER SYSTEM (PWSID# AK2218807) ❑ Well to ed with Onsite (or attached) Well production at time of test m Date drilled Water storage tank volum gallons Total depth ft Well disinfecte coliform test? ❑ Yes ❑ No Cased to ft ❑ C * m bacteria is Negative ❑ Sanitary seal is functioning correctly itrate mg/L ❑ Nitrate less than MRL (ND) ❑ Wires are properly protected c ug/L ❑ Arsenic less than MRL (ND) Casing height (above ground) Collected by Date of flow test for COSA Date of Sample Static water level eginning of test ft. Comm B. TANK DATA Age of tank(S) NEW years Tank type/material PLASTIC Measured operating fluid level in septic tank NEW ❑ Standpipes/foundation cleanout per record drawing Date of pumping NEW D. ABSORPTION FIELD DATA DUAL BEDS Which system tested (date installed) 8/31-9/7/21 ❑ ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade * ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: *SEE ATTACHED RECORD DRAWINGS. COSA Checklist yellow sheet STATION ❑ Requir aintenance comp Age of lift station ye Lift station material Adequacy test date NEW Results Fv Pass For 6 bedrooms Fluid depth prior to test NEW in Water added NEW gal New depth NEW in Elapsed time NEW min Final fluid depth NEW in Absorption rate 900+ gpd Any rejuvenation treatment (past 12 months) N/A If yes, enter date - i 7J E. SEPARATION DISTANCES SERVED BY A COMMUNITY WATER SYSTEM ivate Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Llft Sta tLot > 100' Community Sewer Manhole/_Qlaarrtft > 100' es if No ft Neighboring Tank > 100' ❑ Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No --�i Neighboring Absorption Fields > Yes if No ft Main > 75' ❑ Yes if No ft ❑ Yes if No ft P�t�wer/Septic Line > 25'F-1 Yes if No ft fiidteli Tank > 100' ❑ Yes if No ft Animal Containmen _ ❑ Yes if No ft Manure/Animal Excreta Storage > 1 Surface Water > 100' ❑ Yes if Nofft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0 Yes if No ft Surface Water > 100' Yes if No ft Property Line > 5' 0 Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' El Yes if No ft Private Wells > 100' Yes if No ft Water -Main > 10' Yes if No -ft Community Wells > 200' FvJ Yes if No ft- - Water Service Line > 10' Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Yes if No ft If absorption field is under driveway comment below Property Line > 10' 0 Yes if No ft Wells on Adjacent Lots: Water Main > 10' Yes if No ft Private Wells > 100' [l Yes if No ft Water Service Line > 10' 0 Yes if No ft Community Wells > 200' 0 Yes if No ft Surface Water > 100' El Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION I certify that / have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. • , • • , ... , . • T COSA Checklist yellow sheet fre rness.• V% CE -7953 Q��dprofels•sio0o©o #AECC884