Loading...
HomeMy WebLinkAboutHARMANY RANCH - EAGLET AERIE LT 12Onsite File Harmany Ranch - Eaglet Aerie Lot 12 #050-381-92 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP231140 Work Type: WellSeptic Renewal Effective Date: Expiration Date Tax Code Number: 05038192000 Site Legal Address: HARMANY RANCH - EAGLET AERIE LT 12 G:0260 Site Mailing Address: 8326 HARMANY RANCH RD, Eagle River Owner: DEBONIS RYAN M & ABBY M Design Engineer: FORGE ENGINEERING This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy U � l� J DeI)artnient 6/15/2023 6/14/2024 Lot Size in Sq Ft: 49095 Total Bedrooms: 4 Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: > Su �=C� I Issued By: Date: / Date: 2.o -1- 3 MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 050-381-92 Property owner(s) Ryan & Abby DeboniS Day phone 907-903-7192 Mailing address 16221 Stephan Valley Drive, Eagle River, AK 99577 Site address NHN Harmany Ranch Road Legal description (Sub'd., Block & Lot) Harmany Ranch - Eaglet Aerie L12 Legal description (Township, Range & Section) Lot Size 49,095 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field Initial ❑ Single Family (SF) x❑ Septic Tank ❑x Upgrade 1-1(w/wo AD U) Holding Tank ElRenewal FX Duplex (D) El Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑x Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (5lgnature of property owner or authorized agent) Permit/Rush Fees: r cl 5 Waiver Fees: Date of Payment: gA5X-3 Receipt Number: Permit No. 5 P 31 f yQ Permit App_::- : - : Date of Payment: Receipt Number: Waiver No. June 5, 2023 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Harmany Ranch-Eaglet Aerie L12 Septic System Permit Renewal Dear On-Site Services Engineer: The permit for the construction of a well and septic system on Lot 12, Harmany Ranch-Eaglet Aerie, has expired. A site visit was conducted and there have been no substantial changes to this lot or to the surrounding area since the permit was originally issued. Since that time, however, we have discussed the project with the client and the decision is to adjust the design to specify Cat III Advanced Treatment, due to the variable soils and high groundwater. In addition, the proposed home design has changed. We request a review of this change order in addition to the renewal of this permit. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231140, Curtis Townsend, 06/15/23 ALTERNATE SITE 6' MIN SEPARATION Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 1"=50' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND HARMANY RANCH - EAGLET AERIE LOT 12 FEET 0 50 100 FCO NOTE: NO SLOPES >46% ARE WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM. Jun 13, 2023 H A R M A N Y R A N C H R O A D 4-BDRM HOME 350 360 370 380 390 400 410 15' T&E EASEMENT PROPOSED WELL CAT III ADVANTEX FAP 2.0 SEPTIC SYSTEM MAINTAIN MIN SEPARATION OF 5' FROM DECK POSTS & 10' FROM FOUNDATION TH#1 TH#9A TH#2 TH#2(2013) TH#9 MTMT EXTENT OF MOUND 30' LONG x 5' WIDE, 0.5' EFFECTIVE DEPTH ABSORPTION TRENCH PROPOSED WELLS w/ 100' RADII (PER S/D PLAT) CO CO 2CO ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. LOT 1 CAT III SEPTIC AREA Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231140, Curtis Townsend, 06/15/23 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER Jun 02, 2023 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 5' 6" 6" DESIGN FACTORS:SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: 8.7 MIN/IN APPLICATION RATE: 5 GPD/SF 5' WIDE TRENCH SYSTEM 4-BEDROOM CAT III ADVANTEX FAP 2.0 SYSTEM BOTTOM OF TRENCH: 2' BELOW HIGHEST ORIGINAL GRADE FLOW LINE ELEVATION: 1' 6" BELOW HIGHEST ORIGINAL GRADE RECEIVING STRATA: 5.5' BELOW HIGHEST ORIGINAL GRADE HARMANY RANCH - EAGLET AERIE LOT 12 2' 2" FOAM INSULATION GEOTEXTILE FABRIC 2 1 2' STABILIZE SLOPE w/ JUTE-MESH & VEGETATION/SEEDING AS SOON AS CONSTRUCTION ALLOWS MOA APPROVED FILTER SAND3.5' TOP OF RECEIVING STRATA 600 GPD / 5.0 GPD/SF /5' WIDE * 1.0 [RED. FACTOR] = 24 LF TRENCH REQUIRED (30 LF SPECIFIED) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231140, Curtis Townsend, 06/15/23 \00b,/ / �wZ / ov Z to Unsubdivided N- I rn a O M I N N N Of O Z m rn U � m O a` O e a O O I�aEm0 of a�2cit NI �Nm OC a 040' c.2 N 0 O0 �on0`y ¢^ o c O C3 7 vY 0 P�oNit 0 1+1 0 m o c� �N• z Z ro o Z •R O w W o W00 c° n L C m N / J O \00b,/ / �wZ / ov Z to Unsubdivided N- I rn a O M I N N N Of O Z m rn U � m O a` O e a O O I�aEm0 of a�2cit NI �Nm OC a 040' c.2 N 0 O0 �on0`y ¢^ o c O C3 7 vY 0 P�oNit 0 1+1 O Y m o c� �N• z 0 i o- a FI: Z •R O m m m W o I rDi� L •� 0 w V) L a � � E V) O J 7N M V) En Q C3 a C O KI N IL �`-- C o O a J CL M to M U U U W a O w ° O Y m o 0 0 i o- a O— T m m m W o rnLf Nd c° n L C m N U C N j O O.CL ° O.Z m 0 O a~ 0 ° m m o dZam_ `o V_ m O C C a L0'E- 0 m f 0 N O 0 m mmmar t 0 5:3. O t N c c m pL m Or• O W= V O« O OF'.°° 0 ww 0; m� CL�1 L�Oc 00 OToa m W° T m w 0 gI a V c m a x+ 9 0 0 T O z a:9 y m m Q. MM f O O` _ C O �w'm yt NI w u°i T 0 M a m=0 aE c o V' m m j O D y MM O y c a a00m m0°cL•-E S Em V v m L m m _ a3°cam o M to M U U U W a O w ° MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Water & Wastewater System Permit Permit Number: OSP221008 Work Type: WellSeptic Initial Effective Date: Expiration Date: Tax Code Number: 05038192000 Site Legal Address: HARMANY RANCH - EAGLET AERIE LT 12 G:0260 Site Mailing Address: Owner: VAN METER BEN & ALESYA O Design Engineer: FORGE ENGINEERING This permit is for the construction of: 1»cnt n Department 2/14/2022 2/14/2023 Lot Size in Sq Ft: 49095 Total Bedrooms: 4 Q Disposal Field Q Septic Tank Holding Tank Privy Q Private Well Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: 1. Two test holes are required prior to construction of the absorption field, in the locations shown on the site plan, to confirm minimum separation to impermeable soil and seasonal high groundwater, as well as percolation rate. Construction may proceed at your own risk prior to 7 -day groundwater monitoring. If results require a design change, construction shall stop pending approval of a change order. Please submit results with the inspection report (or change order, if required). 2. Added cover over the fields are to utilized a jute -mesh. Received By: Issued By: Date: Date: Community Development Departmentr_t- Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWERIWELL PERMIT APPLICATION Parcel I.D. 050-381-92 Property owner(s) Van Meter Ben & Alesya O Mailing address P.O. Box 874712 Site address NHN Harmany Ranch Road Day phone (907)229-8117 Legal description (Sub'd., Block & Lot) Harmany Ranch - Eaglet Aerie L12 Legal description (Township, Range & Section) Lot Size 49,095 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑x Initial ❑x Single Family (SF) x❑ (w/wo AD U) Septic Tank x❑ Upgrade ❑ (D) El Holding Tank ❑ RenewalDuplex ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Wellx❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Waiver Fees: Date of Payment: Date of Payment: Receipt Number: Receipt Number: Permit No. Q--'--1022 I00 z5 Waiver No. Permit App_'- : :'-:c February 2, 2022 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 2/2/22 Subject: Harmany Ranch-Eaglet Aerie L12 Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 4-bedroom home on the property, so we are submitting this permit application for the construction of a new well and septic system. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes toward the south, in some areas at greater the 46%. The proposed septic system is in an area where slopes are much milder, however, the it is within 100’ upgradient of those slopes greater than 46%. Please refer to the attached slope cross section for demonstration of the worst-case scenario of effluent travel given the existing grade of the property. We expect no daylighting of effluent. Elevations are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Due to the groundwater depth in Test Hole #9A in conjunction with the depth of receiving soils found onsite in Test Hole #1, ERS may be necessary in order to utilize the receiving soil strata while meeting separation to groundwater. MOA Wastewater Code allows this for CAT III nitrate reducing systems. We would like to propose the use of ERS in this proposed design given the following justification: ERS Justification - The well log for Lot 10 to the east records a clay layer between 69’ and 320’ before drilling to a total depth of 472’. Additionally, a clay layer was encountered in Test Hole #1 at 18’ within 60’ of the proposed septic location. We expect this clay layer to be impervious or nearly impervious, and if effluent should ever reach this depth, it will simply run across the top of the clay strata horizontally and continue downhill rather than intermingle with local aquifers. The property to the south belongs to the State of Alaska Dept. of Natural Recourses and is a part of the Eagle River Greenbelt. There are no private properties downslope of this lot, and so there is no Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221008, Deb Wockenfuss, 02/14/22 potential of any adverse effects from this proposed design on any neighboring lots downslope. We therefore request a variance for the allowance of use of ERS in a conventional septic application. Lot 12 has shown varied consistencies of material throughout historical test holes in various locations on the property. Additional percolation tests will be performed on either side of the proposed septic location in order to confirm consistent soil conditions adequate for this design. Wells on this and adjacent lots are shown. The new system will be a minimum of 50’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 6’ away from the primary. Please refer to the attached test hole logs, slope cross section, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE ALTERNATE SITE CAT III: 24' LONG x 5' WIDE, 0.5' EFFECTIVE DEPTH ABSORPTION TRENCH APP RATE 5.0 GPD/SF Benjamin Schiller CE 12592R EGISTEREDPROFES S I O N ALENGINEER 1"=50' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND HARMANY RANCH - EAGLET AERIE LOT 12 FEET 0 50 100 FCO NOTE: SLOPES >46% ARE WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM. SEE ATTACHED SLOPE CROSS SECTION FOR JUSTIFICATION. NO SURFACE WATER WITHIN 100'.HARMANY RANCH ROAD 4-BDRM HOME 2/8/2022 350 360 370 380 390 400 410 15' T&E EASEMENT PROPOSED WELL w/ 100' RADIUS 1250-GAL SEPTIC TANK w/ 20" MANWAY MAINTAIN MIN SEPARATION OF 5' FROM DECK POSTS & 10' FROM FOUNDATION TH#1 TH#9A TH#2 ≥6' MT TH#2(2013) TH#9 APPROX FOOTING DRAIN OUTFALL LOCATION OUTFALL MUST BE AT LEAST 100' FROM SEPTIC TRENCHES MT CONFIRMATION PERCOLATION TESTS MT MT ≥6' EXTENT OF MOUND 2 - 75' LONG x 5' WIDE, 0.5' EFFECTIVE DEPTH ABSORPTION TRENCHES TIE INTO MIDDLE OF EACH TRENCH PROPOSED WELLS w/ 100' RADII (PER S/D PLAT) FOOTING DRAIN CO CO CO CO 2CO FS ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. LOT 1 CAT III SEPTIC AREA Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221008, Deb Wockenfuss, 02/14/22 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592R EGISTEREDPROFE S S I O N ALENGINEER5' DESIGN FACTORS: SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: 8.7 MIN/IN APPLICATION RATE: 0.8 GPD/SF @ INTERFACE OF ERS/RECEIVING STRATA 1.0 GPD/SF @ INTERFACE OF SEWER ROCK/FILTER SAND 5' WIDE TRENCH SYSTEM 1250-GAL SEPTIC TANK w/ 20" MANWAY BOTTOM OF TRENCH: 2' BELOW HIGHEST ORIGINAL GRADE FLOW LINE ELEVATION: 1' 6" BELOW HIGHEST ORIGINAL GRADE TOP OF TRENCH: NO LESS THAN 2' ABOVE INSULATION 600 GPD / 1.0 GPD/SF /5' WIDE *1.0 (RED FACTOR) = 120 LF TRENCH REQUIRED (150 LF SPECIFIED) 2/14/2022 HARMANY RANCH - EAGLET AERIE LOT 12 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 6" 6" 2' 2" FOAM INSULATION GEOTEXTILE FABRIC 2 1 2' STABILIZE SLOPE w/ JUTE-MESH & VEGETATION/SEEDING AS SOON AS CONSTRUCTION ALLOWS MOA APPROVED FILTER SAND3.5' TOP OF RECEIVING STRATA 600 GPD / 0.8 GPD/SF /5' WIDE *1.0 (RED FACTOR) = 150 LF TRENCH REQUIRED (150 LF SPECIFIED) ERS/RECEIVING STRATA INTERFACE: SEWER ROCK/SAND INTERFACE: Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221008, Deb Wockenfuss, 02/14/22 1"=10' HARMANY RANCH - EAGLET AERIE LOT 12 SLOPE CROSS SECTION 350' EXISTING G R O U N D 0' 2010 0 FEET 380' 375' 370' 365' 360' 355' 5' 10' 15' 20' 25' 30' 35' 40' 45' 50' 55' 60' 65' 33% 17% 36% 55% 46 % A N G L E O F E F F L U EN T I N F L U E N C E F O R A L T E R N A T E & PRI M A R Y S I T E ≤50 % ≤50 % PROPOSED PRIMARY TRENCH #2 PROPOSED PRIMARY TRENCH #1 PROPOSED ALTERNATE SITE PROPOSED FINISH GRADE JUTE-MESH OR EQUIVELENT PROPOSED FUTURE FINISH GRADE OF ALTERNATE SITE 35' Benjamin Schiller CE 12592R EGISTEREDPROFESSIO N ALENGINEER2/14/2022 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221008, Deb Wockenfuss, 02/14/22 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 1 SLOPE SLOPE SITE PLAN DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) J. MILLETTE DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING: IF YES @ WHAT DEPTH?- 8.7 6 6 7 10/15/21 1 2 3 SM/CL (SILTY SANDY CLAY) Professional Engineers Stamp: NO 12' 10/19/21 HARMANY RANCH-EAGLET AERIE L12 10/12/21 050-381-92 RYAN DEBONIS 3:301 2 3 2 4 16 / 6 12 16 4:01 4:32 1' OB 30 Benjamin Schiller CE 12592R EGISTEREDPROFE S S I O N ALENGINEEROctober 19, 2021 SM/GM (SILTY SANDY MATERIAL w/ SOME GRAVEL) CL (CLAY) 2 4 16 / 5 12 16 2 4 16 / 5 11 16 30 30 4 8 16 3 8 16 3 7 16 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221008, Deb Wockenfuss, 02/14/22 DEPTH (feet) PROJECT No.: TEST HOLE 2 SLOPE SLOPE SITE PLAN DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) J. MILLETTE DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING: IF YES @ WHAT DEPTH?4.5' PT (PEAT) Professional Engineers Stamp: YES 3.5' 10/19/21 HARMANY RANCH-EAGLET AERIE L12 10/12/21 050-381-92 RYAN DEBONIS Benjamin Schiller CE 12592R EGISTEREDPROFE S S I O N ALENGINEEROctober 19, 2021 GM/CL (GRAVELY CLAY) LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 UNABLE TO CONDUCT PERCOLATION TEST DUE TO GROUNDWATER (FOR BUILDING SITE) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221008, Deb Wockenfuss, 02/14/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221008, Deb Wockenfuss, 02/14/22