HomeMy WebLinkAboutSKY RIDGE LT 21t � I
DOM
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Water System Permit
Permit Number: OSP231309
Work Type: Well Initial
Tax Code Number: 01527521000
Site Legal Address: SKY RIDGE LT 21 G:2634
Site Mailing Address: 10851 SKY RIDGE DR, Anchorage
Owner: HULTQUIST HOMES INC
Design Engineer: PANNONE ENGINEERING SERVICES
This permit is for the construction of:
❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy
Effective Date:
Expiration Date:
nr s,
Department
9/18/2023
9/17/2024
Lot Size in Sq Ft: 20009
Total Bedrooms: 5
Q Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: � 5 v1'
( _D 1 ` F,S Date:
Issued By: Date: J i/ -2L -2--
MUNICIPALITY F ANCHORAGE
s
Community Development Department �` - Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program el
R � i
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 015-275-21
Property owner(s) Hultguist Homes, Inc. Day phone
Mailing address 12570 Old Seward Highway Anchorage, AK 99515
Site address 10851 Sky Ridge Drive
Legal description (Sub'd., Block & Lot) Sky Ridge Lot 21
Legal description (Township, Range & Section)
Lot Size 20,009 Sq. Ft. Number of Bedrooms 5
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(Z all that apply)
Absorption Field
❑
Initial X❑ Single Family (SF)
ADU)
Septic Tank
ElUpgrade
1-1(w/wo
Duplex (D)
Holding Tank
ElRenewal
ElMultiple
Dwellings
Privy
❑
(SF and/or D)
Private Well X❑
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
Em
(Signature of property owner or authorized agent)
Permit/Rush Fees: S t lam. Waiver Fees:
Date of Payment: 519 /'ZO ZS Date of Payment:
Receipt Number: 0 Rs W T G Receipt Number:
Permit No. 0 S P Z s i 3 0 i Waiver No.
Permit App_'- : :'-.,'c
X❑
Municipality of Anchorage
On-site Water and Wastewater
• • REVIEWED FOR CODE COMPLIANT
Pannone Engineering e r ices LLC OSP231309, Curtis Townsend, 091V
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve@panengak.com
6 September 2023
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road
P. O. Box 196650
Anchorage, Alaska 99519
Subject: Sky Ridge Lot 21
Well Permit Request
Well Design Narrative
This is a design narrative for a permit to install a private well to be issued for this property. Currently the lot has an
existing well that will be decommissioned per MOA code. This lot and the surrounding lots are to be served by
public sewer. Currently there are no sewer mains or private septic systems within 100' of the proposed installation.
1. Initial Well Design.
The well will be located:
100'+ from any sewer main.
100'+ from any on-site septic system.
25'+ from any private sewer lines.
The proposed installation will not affect the future development of this or the surrounding lots.
If you have any questions or concerns, please contact me at (907) 745-8200.
Sincerely,
Is T;�__p
Steven R. Pannone, PE, F. ASCE
Owner/Civil Engineer
Mailing: P.O. Box 1807 Palmer, AK 99645
Telephone: (907) 745-8200 FAX: (907) 745-8201
Existing well located where house is showing on the plot
plan. The existing to be decommissioned per MOA code.
NO WELLS/SEPTICS
WITHIN 200'
OMALLEY ROAD
NO WELLS/SEPTICS
WITHIN 200'
�_
10' T&E EASEMENT
I
M
SS
3S �
ASSUMED SEPTIC �`
Li rl�
SERVICE LOCATION / w
4 V)
W
c� \
BR a
Cn HOUSE
LOT Q
I/ (P) o \
/ 21 -'8 NO WELLS/SEPTICS
�` WITHIN
I
Cn
Cn
ch
I
m
cn
I
cn
I
a
CD
I
01,
LU
it
w
0
0
Of
Y
V)
200
CD I I
N
�R/lrE�gY WELL (P)
� I �
\ NO WELLS/SEPTICS /
WITHIN 200'
w� W�' w�
I
LOT 22
I
For construction PAMONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
DRAWN BY: DRM SKY RIDGE, LOT 21
HULTQUIST HOMES
10851 SKY RIDGE DRIVE
PLAN ANCHORAGE, AK
Date
9/6/2023
Scale
I"=50'
P.I.D. NO
015-275-21
PERMIT NO.
OSPXXXXXX
Sheet
1 OF 2
SPECIAL PROVISIONS TO SPECIFICATIONS On-site Water and V)
1. SCOPE AND SPECIFICATIONS:
REVIEWED FOR CODE
tt
1.1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MOA COMPONENT PARTS AND MA�ERIALIMED IN To
CONSTRUCTION OF ON—SITE WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.55.
1.2. CONTRACTED WORK WILL BE IN COMPLIANCE WITH MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) DIVISION 10 & DIVISION 20 AS
APPROPRIATE.
1.3. SCOPE OF WORK: INSTALL WELL.
1.4.
1.5. STRUCTURES DEPICTED ON THE SITE PLAN ARE BASED UPON ONE OF THE FOLLOWING: CONCEPTUAL PLOT PLAN DEVELOPED BY OWNER; A PLOT PLAN
DEVELOPED BY RLS; OR A SURVEY AS—BUILT.
2. CONSTRUCTION SPECIFICATIONS:
2.1. ALL EXCAVATION DEPTHS ARE ADVISORY. THEY ARE TO BE VERIFIED AND MAY BE MODIFIED BY THE ENGINEER IF ACTUAL FIELD CONDITIONS VARY FROM
THOSE USED TO PREPARE THE DESIGN
2.2. EXCAVATE THE DRAIN FIELD. BOTTOM OF EXCAVATION SHALL BE LEVEL AND SCARIFIED. RECORD ELEVATIONS AT BEGINNING, MIDDLE AND END OF TRENCH
BOTTOM. CONSTRUCTION EQUIPMENT SHALL NOT OPERATE ON THE FLOOR OF THE EXCAVATION. ANY MATERIAL COMPACTED BY THE OPERATION OF THE
CONSTRUCTION EQUIPMENT SHALL BE REMOVED AND REPLACED WITH UNCOMPACTED MATERIAL.
2.3. PLACE THE SEWER ROCK TO THE SPECIFIED DEPTHS. DO NOT CONTAMINATE SEWER ROCK WITH NATIVE MATERIAL OR SPOILS FROM EXCAVATION. LEVEL
ROCK SURFACE TO f1" PRIOR TO INSTALLING THE PERFORATED PIPE.
2.4. ALL PIPE SHALL BE PVC CONFORMING TO ASTM D3034 OR ENGINEER APPROVED EQUAL. MINIMUM SOIL COVER SHALL BE 3 FEET OVER THE PIPE AND 4
FEET OVER THE SEPTIC TANK. ONE INCH OF INSULATION MAY BE SUBSTITUTED FOR 1 FOOT OF SOIL COVER.
2.5. ALL INSULATION SHALL BE 2" THICK DOW HI -40 INSULBOARD OR ENGINEER APPROVED EQUAL. CENTER INSULBOARD WIDTH OVER SEPTIC TANK OR LINES.
2.6. GEOTEXTILE SHALL BE MIRAFI 140S OR ENGINEER APPROVED EQUAL. LAP ALL JOINTS 2 FEET MINIMUM.
2.7. COVER THE DISTRIBUTION PIPE WITH A MINIMUM OF 2" OF SEWER ROCK AND COVER WITH GEOTEXTILE BEFORE PLACING INSULATION AND BACKFILL.
2.8. MATERIAL USED AS FILL SHALL BE CLEAN AND FREE OF ORGANICS, TRASH AND CONSTRUCTION DEBRIS.
2.9. SLOPE ALL FILL MATERIAL TO DRAIN AT 2% MINIMUM SLOPE AND 3:1 MAXIMUM SLOPE AND IN SUCH A MANNER THAT PONDING AT OR NEAR THE DRAIN
FIELD DOES NOT OCCUR. THE FILL SHALL BE LEFT AT 6" HIGHER THAN SHOWN TO ALLOW FOR SETTLEMENT. SEED SURFACE AFTER COMPLETING
INSTALLATION AS PER MOA CODE.
2.10. RECORD THE FINISH GROUND ELEVATION OVER THE BEGINNING, MIDDLE AND END OF SYSTEM.
2.11. MAINTAIN 5' SEPARATION BETWEEN PERCOLATION HOLE AND THE DRAIN FIELD TRENCH.
2.12. EXPOSE, PUMP AND FILL LOG DISPOSAL CRIB OR CONCRETE TANK WITH SOIL TO ABANDON IAW WITH MOA CODE IF NEEDED.
3. CONTRACTOR RESPONSIBILITIES:
3.1. THE CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH THE SITE CONDITIONS AND LOCATIONS OF ALL LOT LINES, EASEMENTS, WELLS (E & P), SEPTIC
SYSTEMS (E & P) AND SHALL MEET MINIMUM SEPARATION DISTANCES OR AS NOTED.
3.2. THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) SHALL HAVE ANY WELL LOCATION AND SEPTIC LOCATION STAKED AND ANY LOT LINE
AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE
WORK.
3.3. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED.
3.4. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES.
3.5. THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING AND LOCATES SHALL BE IN PLACE
PRIOR TO NOTIFYING THE ENGINEER.
3.6. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SITE CONDITIONS/LIMITATIONS
POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN.
3.7. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED—LINE AS—BUILT DRAWINGS TO THE ENGINEER. THE RED—LINES SHALL INCLUDE
PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS, AND TANK ELEVATIONS.
3.8. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF EXCAVATION, TOP OF PIPE WITH CLEAN—OUTS
AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING.
4. THE CONTRACTOR SHALL SIGN THE FOLLOWING: I CERTIFY THAT ALL WORK WILL BE PERFORMED IN ACCORDANCE WITH THE APPROVED PERMIT, AND ANY AND
ALL CHANGE ORDERS, AND THAT THE AS—BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS CONSTRUCTED.
CONTRACTOR: BY:
TITLE: DATE:
construction PANNONE ENG SVC, LLC
P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
SKY RIDGE, LOT 21
HULTQUIST HOMES
10851 SKY RIDGE DRIVE
DESIGN DETAILS ANCHORAGE, AK
Date
9/6/2023
Scale
NTS
P.I.D. NO
015-275-21
PERMIT NO
Sheet
2OF2
0911E