Loading...
HomeMy WebLinkAboutOVERLOOK ESTATES #3 LT 18EO . MUNICIPALITY OF ANCHORAGE aient On -Site Water & Wastewater Program �o Is, PO Box 196650 4700 Elmore Road r Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 ^~ i http://www.muni.org/onsite UehaI- ttnellt On -Site Water & Wastewater System Permit Permit Number: OSP241057 Effective Date: 4/26/2024 Work Type: Wel]Septic Initial Expiration Date: 4/26/2025 Tax Code Number: 06723131000 Site Legal Address: OVERLOOK ESTATES #3 LT 18 G: Site Mailing Address: 27309 WILDE CIR, Eagle River Owner: VIALPANDO JACOB & CANDICE Lot Size in Sq Ft: 54966 Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: 3 This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: • A sieve analysis is required in the location of the proposed absorption fields. If results require a design change, construction shall stop pending approval of a change order. Please submit results with the inspection report (or change order, if required). d R -By: _ .Z ss u e J -rte PSS Date: Issued By: Date: L 47G Z MUHMPA UTY OF A HCHORAGE bqV5%'5A Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 067-231-31 Property owner(s) Jacob & Candice Vialpando Mailing address Site address NSN Wilde Circle Day phone Legal description (Sub'd., Block & Lot) Overlook Estates #3, Lot 18 Legal description (Township, Range & Section) Lot Size 54,966 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial ❑X Single Family (SF) ❑X ADU) Septic Tank IRUpgrade F-1(w/wo (D) ❑ Holding Tank F-1Renewal ElDuplex Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑X Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. SRP (Signature of property owner or authorized agent) Permit/Rush Fees: -� l 312. Waiver Fees: Date of Payment: Receipt Number: Permit No. DSP 2H ) 05 7 Permit App_.:- : , _..:c Date of Payment: Receipt Number: Waiver No. Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E‐mail: steve@panengak.com Mailing: P.O.Box 1807, Palmer, AK 99645 Telephone: (907) 745‐8200   FAX: (907) 745‐8201 Municipality of Anchorage Development Services Department On‐Site Water & Wastewater Program 4700 Elmore Road Anchorage, Alaska Subject:   Overlook Estates #3, Lo 18          Well and Septic System Permit Request This is a design narrative for a permit to install an initial septic system and well on the subject property. The proposed system will serve a proposed three‐bedroom (3) house. This lot and surrounding lots are served by private wells. 1. Soils. 28 test holes were performed in this subdivision by PES for the approval of the subdivision, and more were performed during the design of septic systems on lots in the subdivision.  The shallowest groundwater observed in the subdivision was at 13’ on lot 26, directly adjacent to a stream located on the far end of the subdivision. Bedrock was not encountered anywhere in the subdivision. The test holes in the area were all found to have a percolation of less than 5 MPI, most less than 1 MPI. See soils logs for subdivision, S12577.  The test hole on lot 18 was performed further to the northwest than the system will actually be installed.  We are using surrounding test holes as a justification. Based on the results of the surrounding percolation tests and known soil types in the area, per 15.65.210 C; a conservative application rate of 1.2 gallons/day/square feet was used for a conventional wastewater system.  A sieve analysis will be performed on the soil in the area of the drain field to verify the in‐ situ sand, and a change order will be submitted if the soil is found to require a sand filter. 2. 3. Soil Absorption System Design. a. See Sheet 1 of the design package. 4. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. 5. Topography: See attached site plan for area topography. There are no slopes exceeding 25% less than 50ft from the proposed drain field. 6. Drawing Markings: The Drawings are marked “For MOA Review Only”. When written notification that the review is complete and no further comments are received from MoA On‐Site Department, the note will be removed and “For Construction” drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. If you have any questions or concerns, please contact me at (907) 745‐8200. Sincerely, SRP Steven R. Pannone, P.E. F. ASCE Owner/Civil Engineer 26 April 2024 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241057, Deb Wockenfuss, 04/26/24 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241057, Deb Wockenfuss, 04/26/24 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241057, Deb Wockenfuss, 04/26/24 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241057, Deb Wockenfuss, 04/26/24