Loading...
HomeMy WebLinkAboutGOODMAN LT 2Goodman Lot 2 #018-321-13 Municipality of Anchorage Page 1 of 3 Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage. AK 99519-6650 www.d.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW030421 PID Number: 018.321-13 Name: Tim othy Peters Wastewater System: New Andress' 4909 Castle Court Anch., AK 99507 ABSORPTION FIELD per. NWrDerofI edraor.e: 276.5307 Five 5 Deep Trench LEGAL DESCRIPTION SodRating: Taal Depth ham onginal grade: .6 GPDIFIe 10 Ft. block: Lot* SuodMvon: Deptbppe Oollan hom On)pW Pane: Gravel(teat beneath pipe: 2 Goodman 4 Ft. 6 FL Tovetsmp: Rage: sechan: FYI sooeo above ong.Y Pada: Gavel Length: 0-2 Ft. 115 Ft. Well: New Gavel a M NunD of knee: paunca OalMen ane,: 3 Ft. 2 >12 Ft. W smuuon (Pnvele. A. e. C): Total Dept: Cased to: Total absorption area: --pe evale. W: Private 100' 99.21 1,380 Fir ASTM 3034 PVC Duper: Dale paled: slaw Willer Levb: wear: la staled. M -W Drilling1 O/d.0/03 Hillside Landscaping 10117.2412003 Yield: Rom set al: Caung HV9hI Above Gwnd: TANK . 15 GPM FI. >2 Fl. SEPARATION DISTANCES 0 Septic ❑ Holding Cl S.T.E.P. ❑ Other. To I Septic Absorption Lift Holding ublic/Pavata a' `` w y' . From Tank Field Station Tank seaerun , Anchorage Tank 1,500 wee >100, >100' NIA NIA >25'Steel Two (2) tangy. suHace walla >100' >100' N/A N/A LIFT STATION — NONE ON LOT wune >5' >10' NIA N/A a a W, FalaNakan >5' >10' NIA . � NIA unpan ev a: unp eve a: •aer a•am a: t Canaan I}sin None Noted Punp Make a _MWel FJa Vain lnepaotio.0 WbhhM by: Rawn,'fa BENCH MARK ora on wap on: Top of Foundation Wall. -Mr 100.0 FL Engineer's Stamp OF iri0 ... Inspections MEA performed by: Dates: 1a' 101117/20030 �, 49th V�� 2nd 1012312003 % �'• .... � Department of Health and Human Services approval as•� j MICHAEL E. ANDERSON { y. .Q �J. s JA(1� ♦ ;. No. CE -4781 1 �<- Reviewed and approved by Date. ia P�44.' /'I A 4r,a�OFESSt�..� , Municipality of Anchorage Page 2 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: SW030421 PID No. 018-321-13 LOT 201 LOT 200 N89'57'57"E 155.75' 16 6, 10' TELE. ESMT. SK 770, PG 40 10.0' TELE. & ELEC. ESLR. 10' EACII Z SIDE OF EXISTING ELECTRIC UNE o BK 121, PG 273 V O fy O o O y f zo 9.4 EAVE LINE A B a SI 40.8 43.7 46.0 S2 47.0 53.8 Ued,,Om C4 98.3 112.3 House to MI 101.0 114.0 'off ' o ��� C6115.5129.0 CV �o M2 116.2 128.6 m C5 129.10 121.3a o C7 149. 142.4 2 m LOT 1 PROPOSEO�::':•::' z LOT 212 LOT 2 -GRAVEL: :'::: m p 78,915 SQ.FT. DRIVE::. o � U C9 :. Svc v ryp � b �do -'1OS0 ,y00 c. A O' r/19, �O• O v?, I S' BLIA ROW l RESERVE (}. O � �o�,,•s ��'a R% DOR AVE. .. o • LOT2 o . ROAD. G�AVF1 229 stnry'>-:'.'.'''.'ia':::•r:.:'r.r:'. X.- �:'•..:': ,. 7 7 , _1'leo :............ ro O:F.:. pFgoF LOT 3 Quo G7 .e o*, h/yss.: LOT 229A >' OF r LOT 230A':; :.. ���P. .....A q 49th AS -BUILT PLAN 1.C% AELE.ANDERSON ' No. ce-43e1 , SCALE V • 6a 0`;_....................... LOT 2, GOODMAN SUBDIVISION Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage. AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number. SW030421 PID No. 018-321-13 V Uz v x N U NORTH LEG W N U = n U 89.0 84.01 --' ll Drnlnfletd Rock 78.0 LL 60' (Trench Length) SOUTH LEG PROFILE AS -BUILT Scale: V • 10' M -W Drilling, Inc. *P.O. Box 110378r•Anchorage, AK 99511♦ •907-345-4000 • 907-345-3287 Fax* Job No.: 03-187 Parcel No.: 018-321-13 Permit No. SW030421 ♦ Nell Owner. _ ♦ Legal Description: Groundwater Well AS -Built & Lon Court - Lot 2 Construction • Use of Well: Domestic ♦11ole Depth: 100' •Casing Size. 6" ♦Cased To: 99.2' ♦Alaterial. A 53 Steel ♦DrillAterhod. Air Rotary ♦ Nell Completion- Open end X Screen Perforated ♦Screen/Perjoration description: None *GroutNotes.- (1) Sack- No. 8 bentonite granules ♦ Notes: req. -- -- - - Alethod: ♦ Well Development: Alethod: Air surge Notes: *Static water level (SIVL) (above) (below) top of casing (TOC). ♦ Well yield test at 15+ gallons per minute (GP,11)/geliensper6ewr{Gp/1) jar I hours with 100% of drawdown (DD) from static level (SIVL). ♦Alethod: Airlift ♦ Date of completion: 10 October 2003 • Pump Install. Well 1,00 Depth in feet from top of casing. Details of formations penetrated, size of material color and hardness. 0 TO 2.5 Casing stickup 2.5 TO 6 Top soil, overburden 6 TO 97 Interbedded layers of silty ravel and clay 97 TO 100 Water ravel: sand TO TO TO TO TO TO TO TO TO TO TO TO TO NIVIVA-Certified-contracto certulcate No's ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX MEMORANDUM DATE: December 5, 2006 TO: Jeff Poet FROM: Mike Anderson, P.E. SUBJECT: Lot 2, Goodman Subdivision Certificate of On Site System Approval M -W Drilling has placed the identification tag on the well which was required prior to issuance of the as -built certification for the well and septic system. They have also tightened the well head to satisfy all remaining comments from our original inspection report submittal more than three years ago. r /°•7.03 @ MUNICIPALITY OF ANCHORAGE l jL3 v Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 995196650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Permit Number: SW030421 Legal Description: jGoodman Lot 27 Design Engineer: 0041 AK Water & Wastewater Consultan+ Owner Name: Timothy Peters Owner Address: 4909 Castle Court Anchorage, A 99508 - VF:o° Date Issued: Oct 08, 2003 Expiration Date: Oct 07, 2004 Parcel ID: 018-321-13 Site Address: 4909 Castle Court Lot Size: 78915 So. FT. Total Bedrooms: 5 Permit Bedrooms: 5 This permit is for the construction of: ❑✓ Disposal Field 0 Septic Tank Holding Tank ❑ Privy ❑✓ Private Well Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Date: Issued By: /1 1_f"'L Date: 101 5 v municipality of Anchorage ,t evelopment Services Department � Building Safety Division ' 3 On -Site Water and Wastewater Program q 4700 South Bragaw St. P.O. Box 196650 Anchorage. AK 99519-6650 www.ci.anchorage.ak.us 3,13-79 .ak.us (907)343-7904 ON-SITE SEWERIWELL PERMIT APPLICr-i�—,ji, FOR A SINGLE FAMILY DWELLING Parcel I.D. J/l " 3)i - / < Permit Number SW '4&sy Property owner(s) I%rrb AU / e) e1, f Day phone ] 7E - ti ; 07 Mailing address (1) L(yh°I CA --A 4 �ti f /h1.%: ' �k l L:..p Mailing address (2) Zip Code Legal description (Lot. Block & Sub'd.) �`c•'=t "� �•1 tic �,-�'r c'.r Legal description (Section. Township & Range) Lot Size 2E, :It Acres/Sq.Ft. Number of Bedrooms THIS APPLICATION IS FOR: Sewer Only ❑ Well Only ❑ Sewer and Well [ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling ^and is In a ordance with applicable Municipal Codes. of properly owner or authorized agent) Permit Fees: r Fees: Da'e of Payment: "1 1 / Receipt Number: (Re, 12,00) Date of Payment:/Ob-3 P.eceipt Number. _4 3fo CalICA) Bay- Sol ( wk) 2"74, - 5730% ALASKA WATER �& WASTEWATER CONSULTANTS, INC. October 6, 2003 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Proposed Well and Septic System for Lot 2, Goodman Subdivision To whom it may concern: The proposed 5 bedroom house will be served by a private well and septic system. Three test holes were dug on the property. The drainfield will be designed around the 30 foot radius of test holes #2. We are proposing that a 1500 gallon septic tank and also dual deep trench type drainfields be installed. Comments regarding the design are summarized as follows: 1. SOILS: See the attached log which shows the soil classifications, groundwater monitoring, and the percolation test results. It is our opinion that due to the overall appearance of the soils, an application rate of 0.6 gallons/day/1t2 should be used. 2. TRENCH DESIGN: a. Percolation Rate: 21.8 minutes/inch b. Proposed Application Rate: 0.6 gallons/day/ft c. Number of Bedrooms: 5 d. Design Flow: 750 gallons per day e. Minimum Absorption Area: 1250 f12 f. Total Depth: 10 feet (max.) g. Effective Depth: 6 feet h. Width: 2.5 feet i. Reduction Factor: N/A j. Minimum Length: 55 feet long each (I 10 feet long total) k. Effective absorption area = 1320 ft2 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. In short, there are no slope concerns. 3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507 Ph: (907) 337-6179 0 Fax: (907) 338-3246' Website: akwwc.com 4. TOPOGRAPHY: As can be seen on the attached design drawing, the average topography in the area of the proposed drainfield is a 1-5 percent slope running approximately northeast to southwest. In short, there are no slope concerns. I am unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. .E., M.S. NOTE: Attached is a site plan drawing, a design drawing, a topography site plan, a soils log, and a 7 page construction specification letter which are all part of the design package for this septic system. 3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507 Ph: (907) 337-6179' Fax: (907) 338-3246 • website: akwwc.com I eaDp0511� \ ,\ PROPOSED O S BEDROOM HOUSE \ r PROPOSED SEPTIC SYSTEM _- AyTEIQTE SffE (SEE DESIGN PACE 2 OF 2 LOT 212: SW 1/4, O TM/J SECTION 33, T12N, R3W c` i T, \♦ COLDPAN�TATES S/D Q ,\ LOT 4 THI, ~t 12 \ � nrin• •,mu,,r � � \ r CHUCKS BACKHOE GOLDPZTES S/DLOT 10/6/2003 ALASKA «TATER R WASTE«'ATER DRAWN C 1.G• CONSULTANTS, INC. SCALE, d 1" = 100' t ............. PREPARED FOR PHONE NUMBER: PAGE NUMBER: TIM PETERS 332-2012 1 OF 2 'y •J ffr y I. Car a s.-. 9 LEGAL DESCRIPTION: 79$3 GOODMAN SUBDIVISION, LOT 2, y�,°� ��F•'.' TYPE OF WORK: y1�r�:��P�o eeslono�" SITE PLAN FOR PROPOSED WELL LOCATION AND SEPTIC SYSTEM / v � LOT LOT 200: SW 1/4, / 33 T1 R3W SECTION 33, 2N. SECTION 33, T12N/ R3W / N % sn /r N `\ V // � 1 qEEPRC ARS / I eaDp0511� \ ,\ PROPOSED O S BEDROOM HOUSE \ r PROPOSED SEPTIC SYSTEM _- AyTEIQTE SffE (SEE DESIGN PACE 2 OF 2 LOT 212: SW 1/4, O TM/J SECTION 33, T12N, R3W c` i T, \♦ COLDPAN�TATES S/D Q ,\ LOT 4 THI, ~t 12 \ � nrin• •,mu,,r � � \ r CHUCKS BACKHOE GOLDPZTES S/DLOT 10/6/2003 ALASKA «TATER R WASTE«'ATER DRAWN C 1.G• CONSULTANTS, INC. SCALE, d 1" = 100' t ............. PREPARED FOR PHONE NUMBER: PAGE NUMBER: TIM PETERS 332-2012 1 OF 2 'y •J ffr y I. Car a s.-. 9 LEGAL DESCRIPTION: 79$3 GOODMAN SUBDIVISION, LOT 2, y�,°� ��F•'.' TYPE OF WORK: y1�r�:��P�o eeslono�" SITE PLAN FOR PROPOSED WELL LOCATION AND SEPTIC SYSTEM IVIG: IML GUMIKAGIurc DMALL HAVL IFR B' VISUAL ENHANCEMENT EASEMENT AND THE PROPOSED 100' WELL RADIUS STAKE OAND FLACCED PRIOR TO CONSTRUCTION. PROP 5 HOUSE FOUNDATION CLEANOUT m bLW.VVIi PROPOSED DRAINFIELD EXCAVATE TWO ENCHES THAT ARE 10 FEET DEEP MAXIMUM BY 2.5 FEET WIDE BY 55 FEET LONG EACH (I 10 FEET TOTAL LENGTH) ADD 5 FEET OF \ CLEAN. WASHED SEWER DRAINROCK. \ I \ \ \ IN SP�<nTEROW DORA _AVENU_E\ ,�•;:; ADVAHTEX TRE .x. 10/6/2003 C.J.G. _ALASKA 11"XI7?R & WASTE«'APER SALE: ----- CONSULTANTS, INC. 11" = 40' 3701 F TUDOR ROAD"DN , SUITF 101 • ANrHOPAGF. AK RR507 • PF (9071%N74,170 • FAX IW1133!•37/.M1 PREPARED FOR: PHONE NUMBER: PACE NUMBER: TIM PETERS 332-2012 2 OF 2 GOODMAN SUBDIVISION; LOT 2 DESIGN DRAWING FOR PROPOSED WELL LOCATION AND SEPTIC SYTEM I I I I L.. /WILL OF AN CYTS ALASKA NVATER & WASTI NVATER CONSULTANTS. INC. SOIL LOG — PERCOLATION TEST LEGAL DESCRIPTION: GOODMAN SUBDIVISION; LOT t & 2. PERFORMED FOR: LANTECH DATE. --9/22/2000 DEPTH _i_ (PAGE 1 OF 2) (feet) __ORGANICS TEST HOLE #11 1 • •.•. •. IMEy• DRY 10/3/2000 '•, of aA. Garness:' muwi 7953 111191 \FG iiia. 3:04 IMM, 5 7/8' 8"3 1/8- mam 3 • ME 6- — ►111u111 4 3:34 - 5 15/16- ioa. 5 3:34 — 6. — ��i� v.4 6 4:04 DEPTH TO GROUNDWATER DATE DRY 9/22/2000 DRY 10/3/2000 '•, of aA. Garness:' •• C 7953 `` �.�s��o 4 NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) '•, of aA. Garness:' •• C 7953 6- \FG �O o 4TH13 f �°vc `'11 ,;TM12 i I TH 1 1 I\ DORA XVENUE \ SITE PLAN — -- 1'-100' DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 9/28/2000 1 2:34 — 6- — 2 3:04 30 5 7/8' 8"3 1/8- 3 3:04 — 6- — 4 3:34 30 5 15/16- 1/16- 5 3:34 — 6. — 6 4:04 30 5 7/8- 1/8. 19� PERCOLATION RATE 240 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 8.5 FT. AND 9.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑NO SOILS L3GGED BY: CINDY ELLIS PERCOLATION TEST PERFORMED BY: JOE MARCHETTI COMMENTS: PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WA$ PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 'o b 03 ALASKA NIVATKR & WASTK"'ATI?R CONSULTANTS. INC. SOIL LOG — PERCOLATION TEST LEGAL DESCRIPTION: COODMAN SUBOMSION; LOTS 1 k 2 PERFORMED FOR: LANTECH DATE; 9/22/2000 DE (PACE 2 OF 2) fleet Fl TEST HOLE #11 2 3 a N 5 W O 6- 7— 7 Lit a 8— z Z O 10 Q U 1 t ti. Ln 12 QN J U 13 _J 14 O V) 15 W W N 16 17 18 r DEPTH TO DATE GROUNDWATER o z E PPGE , 5 of a A. Gamess. 0�r —7953 •' `F`Q Op_e ..... . O SEE SITE PIAN (PAGE 1 OF 2) DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) - 1 IIIIIIIII - 11:11191 - %//% 3:01 jr%/J�. 3 3/4- 2 1/4- NHH • WN — 6- IIIIIIIII um 3:31 30 VZZZA 1 1/2- 71521�1i 5 3:31 YIV�. • 6 4:01 DEPTH TO DATE GROUNDWATER o z E PPGE , 5 of a A. Gamess. 0�r —7953 •' `F`Q Op_e ..... . O SEE SITE PIAN (PAGE 1 OF 2) DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 9/28/2000 1 2:31 - 6- - 2 3:01 30 3 3/4- 2 1/4- 3 3:01 — 6- — 4 3:31 30 1 4 1/2- 1 1/2- 5 3:31 6' — 6 4:01 30 4 1/2- 1 1/2- 19 I I PERCOLATION RATE 20 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) �j�_JII TEST RUN BETWEEN •k 8.0 FT. AND 8.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO SOILS LOGGED BY: CINDY ELUS PERCOLATION TEST PERFORMED BY: JOE MARCHETTI PERFORMED BY ALASKA WATER do WASTEWATER I, JEFFREY A. GARNESS, CERTIFY THAT THIS IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: i 0 foo ALASKA WA1'L'R & VL'ASTKWATI�R CONSULTANTS, INC. >* p SOIL LOG — PERCOLATION TEST D LEGAL DESCRIPTION: GOODMAN SUBDIVISION: LOTS , & 2. p Jef e G mess; QIP o PERFORMED FOR: LANTECH DATE: 9/23/2000 p0 —7953 .p DE Q��oe� Pio f eeelo�o� Foc (feet) TEST HOLE 7#21��40000�00 ORGANICS —== SOIL CLASSIFICATIONS GW ORG FILL 3 : GP ML =___ ----U GM CL 4 GC OL SM SW MH 0 .' 5— Jill SP CH SM i OH + j3 6 •++ }} SC 7 +T II 1i1iDEPTH TO ♦ I TH/1 8 DRY 9/23/2000 9 `� DORA VE_ SITE PLAN ��\------�' 1•=100' 10 1t } SM (GRAINY) DATE READING CLOCK NET TIME WATER LEVEL NET DROP ,2t 13 14 15 16 B U.11. 17 16 19 PERCOLATION RATE 21.8 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 4.0 FT. AND 4.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO SOILS LOGGED BY: CINDY ELLIS PERCOLATION TEST PERFORMED BY: JOE MARCHETTI COMMENTS: PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS W P RFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: !a1" 0 3 DATE GROUNDWATER DRY 10/3/2000 TIME (MINUTES) READING 9/28/2003 1 2:33 — TIME (MINUTES) READING (INCHES) 9/28/2003 1 2:33 — 6• — 2 3:03 30 4 1 2• 1 1 2• 3 3:03 — 6• — 4 3:33 30 4 7 8• 1 1 B' 5 3:33 — 6• — 6 4:03 30 4 13 16• 1 3 16• DEPTH TO GROUNDWATER DATE DRY 9/20/2003 R Ib o 1:56 • a�9pF ALASKA NNTATI?R & «'AS"I'1✓WATER 2:06 CONSULTANTS. INC. 3 SOIL LOG — PERCOLATION TEST 0. .. „ ........ LEGAL DESCRIPTION: COODMAN SUBDIVISION; LOT 2 OQ m•.J f y e ��°or C 7953 a PERFORMED FOR: nM PETERS DATE: 9/30/2003 ti80 0 DEPTH (feet) (PAGE 1 OF 2)edPro/eeelo�° ORGANICS TEST HOLE#31�D0000��o _ — 6" — 6 2:27 2 SOIL CLASSIFICATIONS ---- GWORG ---- 0 3 — 6" — a+r; GP ML GM, LARGE 8 2:40 10 1" 5" GM CL aC088LES 9 I GC OL � • °9 °°. SW MH .� 5 .6 3 SP CH ' � 2:50 — 6" — SM OH i 6 3:00 10 1 1 2" 4 1 2" SC ` 4TH/3 7 I 'iiB ,, `\` �TM,2 I \ ��o `\1% 8 THJ1 I '. } 9 • ; DO'RA-X�VENUE SITE PLAN 1"-100• 10 SM 11 12 13 14 '} ., 15 fj I }Tj.} +'11 16 B.0.11. 17 18 PERCOLATION RATE 2.2 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 TEST RUN BETWEEN 2.0 FT. AND 2.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO SOILS LOGGED BY: SUSAN OSWALT PERCOLATION TEST PERFORMED BY: SUSAN OSWALT COMMENTS: Al INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS E ORMED IN ACCORDANCE PERFORMED BY WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: C DEPTH TO GROUNDWATER DATE DRY 9/20/2003 R Ib o 1:56 — 6" — DATE READING CLOCK TIME NET TIME WATER LEVEL NET DROP (MINUTES) READING (INCHES) 10/1/2003 1 1:56 — 6" — 2 2:06 10 1" 5" 3 2:06 — 6" — 4 2:16 10 1" 5" 5 2:17 — 6" — 6 2:27 10 1" 5" 7 2:30 — 6" — 8 2:40 10 1" 5" 9 2:40 — 6" — 10 2so 2" to t t z" a 1/2- 11 11 2:50 — 6" — 12 3:00 10 1 1 2" 4 1 2" 2 3 a C4 5 LL- 0 LO 6- 7— 7 W C� Q 8 v 9 (1) Z O 10- 11- 12- 0 11 12 U 13- 14- V) 314 V) 15 W W V) 16 17 18 - 111111111 CLOCK TIME NET TIME (MINUTES) ALASKA. WATER & AVASTK'NVATKR o� '1-4I 1:54 CONSULTANTS, INC. NNE 111111111 • ot7M-RW.-a0rtt�o - e.aom 30 5 1/2- 1/2- +`in lifflli SOIL LOG — PERCOLATION TEST 0 aP.M. LEGAL DESCRIPTION: GOODMAN SUBDMSION; LOTS 1 & 2oOo P '•.Je f y hQ� E 7953 ss.: ` PERFORMED FOR: TIM PETERS DATE: 9/30/2003 ..•f `F6 DEP (1°°t (PAGE 2 OF 2) EST HOLE#31��000000���� -k°^°O e•s••\�o� 1 3:24 30 5 1/2' 1/2- 2 3 a C4 5 LL- 0 LO 6- 7— 7 W C� Q 8 v 9 (1) Z O 10- 11- 12- 0 11 12 U 13- 14- V) 314 V) 15 W W V) 16 17 18 DEPTH TO GROUNDWATER - 111111111 CLOCK TIME NET TIME (MINUTES) 1 1611111 %//% 1:54 — NNE 111111111 • Ow 2:24 30 5 1/2- 1/2- +`in lifflli YIf/B. • aP.M. 6" — DEPTH TO GROUNDWATER DATE CLOCK TIME NET TIME (MINUTES) ,OF2 ?POE 10/1/2003 SEE 1:54 — 6- — SEE SITE PLAN (PAGE 1 OF 2) DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL NET DROP READING (INCHES) 10/1/2003 1 1:54 — 6- — 2 2:24 30 5 1/2- 1/2- 3 2:24 — 6" — 4 2:54 30 5 1/2- 1/2- 5 2:54 6' — 6 3:24 30 5 1/2' 1/2- 19 PERCOLATION RATE 60 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 7.0 FT. AND 7.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO SOILS LOGGED BY: SUSAN OSWALT PERCOLATION TEST PERFORMED BY: SUSAN OSWALT COMMENTS: PERFORMED BY ALASKA WATER & WASTEWATER I, JEFFREY A. GARNESS, CERTIFY THAT THIS W ERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDEUNES IN EFFECT ON THIS DATE: v 14.4o.; an 11 TELE. & ELEC. ESMT. 10' EACH SIDE OF EXISTING ELECTRIC LINE BK 121, PC 278 49L 6ov� N. .6;1 r er LS -10392 yOk 14��w�Fes Sion at `'o-7 61 LOT 2 1 .4 LOT 1 LOT 201 116.4 1 O PFS 1096 N89'57'57"E 155.75' 10' TELE. ESMT. BK 770, PG 40 on 7 PFS 1C8.6 EAVE LINE - _ A� PFS 108.6 PSSEDE 4 �FLR LR_109.1' 1 LOT 2 78,915 SQ.FT, Q66 Z/C .` C'n ``% q F �`. O 10 .9 ys� ?o�p , SF, Sq %`` FS� � ACF LOT 3 r LOT 230A F=' a 7- E:: FR S; j``I r• •A.j _ �AFi & CUNSTRUCIIGN SURVEYORS -PLAT 44( VE='. BENSON BLV''. N 103 AN::iIgR.1'"oc, ALASKA 99503 NJ41, )f C.d ' J14C2• puEPt " ST. 1G. 20031"1--50* 1'50' JI✓1Ai NPd. I OMD.I 3134 on LOT 200 LOT 212 3' BLM ROW RESERVE 107.9 CORA: AVE. o ......... ....... :ROa�':: T 229 LOT 229A PFS 1096 PROPOSED FINISH GRADE 1 DRAINAGE 1! EXCLUSION NOTES: I: b the 0+rere' raspanslhllitY to 4-t-11"1110 the aKislence Jf any aasemenb, CO"nunls, or restric Uons !/CR9 W/CAP(il 5/6' RU �I whl •h do not oppear on the recorded subd:vlslon Plot. 14UTE: It 3.25• ALMON, 0lIr,NCMt'NT Is the contractors responalbillty to check top of foundotion grade and buiding setbacks In relation to IoUlnes and SIM t3. HUB G 7ACK EI FCNCE— --K--• K —+ SURVEY CERTIFICATION: LANTECH has conducted a OVERHANG— €_—_°-? physical survey of this Properly as shown on this drowlnq and to the best of our knowledge and ODs:Lles. CII dlmansiona have been measured t Mo WOOD BECKS— � 1 I CONCRETE— E..�- I ASPHAL.T— and correct. SEPTIC STANGVIPES—(}� WARR WILL— PLOT PLAN OF: IEGAL OESCRIPnGN: EtEV.(NO CATUM)-Lm c _1 - ENGINEERS LOT 2 .5G2-52.91 0.2-139 SUBDIVISION M7 Acs GOODMAN 2/52 >rov�s m r I I �11 Ali 111111 1 11 a rt & " 1i J! --TRAIL"=-- Rd"' '! I If PORCUPINE11 11.1, % / 1011t I II so ON 2 'k L7 I 149M UJ am 14,41 ON am -J z h 90 DA 1,060 W DIEN =VF. w Mar Now ON IMMAO64NDE : us a 'T , j Ift S K" LM ING, PKAOS'NOE us ; 71-y CHENOWETIr St RAE BIT-113REE" d —,J All "J, M223 �K Co allowsN AE ix ItIL-Ave V 7 F11 I 164M AVE 4152 Active Address 5261 Preliminary Address (Subject to Change) N Pubfic Road A SWI ILS —SW3035 Private Road !N 4 1 Planed/Not-Built Road Municipsky of Anchorage This p 6 dNived Im. G.*g,.phic Info~mn eye... dit. clovelopad am ..irasinad by 111'a 3133 Office of Economic and Community Deva Ment of A.M.�IMQAI.Thi. so 1. not Planning Department - Technical Services Division the ". off.isl raprsaar*.eon of any of th. 4700 Biagao, Street Pa Box 196650 lrdm.t.n W.Judid am is ON.& available W ths pNNblw solly for W.minal "".. 11 Anchorage. Alaska 99519-6650 TN. map may be amdal.d. b,scatww. and ., Do net .it iMpNxt.Mtapyort November 18, 2004 kdcamat., Th. Municipality of A.lN..q. Z SW 3233 rot b. rbi. lo, law cutacias cwemiswons inme map. Anchorage Area Atlas reference number: 361 �a Ao W 6A1 --<<ana L Municipality of Anchorage Development Services Department Building Safety Division Onsite Water and Wastewater Program 4700 Bragaw, Street P.O. Box 196650 Anchorage, AK 995196650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 018-321.13 1. GENERAL INFORMATION Complete legal description Lor z Goodman subdivision Location (site address) 3231 Dora Avenue 47.d�,o Leb�C COSA # O(n 05:3 4 Expiration Date: 3Z/f 07 Current Property owner(s) Timothy Peters Day phone T70-1616 Mailing address 3231 Dora Avenue Anchorage, AK 99516 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be heli by DSD for pickup 2. NUMBER OF BEDROOMS: Five (5) 3. TYPE OF WATER SUPPLY: Individual Well❑ Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual On-site 0 Individual Holding Tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -She Systems Approval (COSA) based only upon the representations given In paragraph 4 by an Independent professional civil engineer registered in the State of Alaska. Certificates of Onsite Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of Onsite Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of OnSfte Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system Is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Finn Anderson Engineering Phone 522-7T73 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 12/42o06 V 49th 5. DSD SIGNATURE Approved for 5 bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Nitrate Advisory Other BY _ Original Certificate Date: O rR«.,,usm Municipality of Anchorage • Development Services Department Building Safely Division On.Site Water 6 Wastewater Program 4700 Bregaw, Street P.O. Banc 190650 Anchorage, AK 99519-650 wwwmlmlorglonsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Let$ Gooarrrsn SubdNMan Parcei ID: 018+=-13 A. WELL DATA Weli type Lit H A, S. or C provide PWSID S _ Date eomplew Lam --a 9 Sanitary seal (Y" Y Total depth -M—ft. Cased t0 –n—& FROM WELL LOG Date of test 11M. I 9 Static water level Udmawn IL Well production 15+ g.p m. WATER SAMPLE RESULTS: Coliform o aobNesM00 mL Nnnete NID mg& Arsenic: 22.8 RW Date of sample: 11 rAw B. SEPTICIHOLDING TANK DATA Tank TypelMatedel soodstew Wen Log (YIN) Y Wires property protected (Y" Y Casing height (above ground) >u in. AT INSPECTION llreormoe e7 R 3.7 g.p.m. Other bacteria o colonieV100 mL Collected by: F. LeDom Date Installed 10n7rmoa Tank sae 1.800 gal. Number of Compartments TWO Cleanout (YIN) Y Foundation deanout (YAC Y Depression over tank (YAC N High water alarm (Y)V) N Date of pumping 1X5 008 Punk Ord mcoonews Purnpi g C. ABSORPTION FIELD DATA Date intellect 1on7,2slsoos Son rating (g.p.dARe or fftdrrn) •e GP=—F System type Deep Trendy -------- —. --- --- �gti�--11a-- - �-._--y--------- ---�------Gravel below-D� - e ----- _R -------- _ Total depth 1a12 it El absorption area mil= Mon toAng tube Y Depression over field N Data of adequacy test 11=40 Results (Pass/Fan) Pan For 5 bedrooms Fluid depth in absorption f M before test EI10 in. Water added 752 gal. New depth M in. Elapsed Time: 1x40 min. Final fluid depth e7IIb ht. Absorption rate Iso g.p.d. Any rejuvenation treatment (past 12 ma) (YIN a type) N If yea, give date wy .C'<;�taC�u; {.: _ .:::��; ;.:._:_. Municipality of Anchorage .._ . • ''` Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 Arsenic Advisory Certificate of On -Site Systems Approval # 060574 A Certificate of On -Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Lot#Lof Goodman Subdivision. This inspection revealed an arsenic concentration of 22.8 micrograms per liter (ug/L) for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Information on arsenic is available from the On -Site Water and Wastewater Program website (www.muni.org/Onsite) or at 343-7904. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Septic System Advisory Health Authority Approval # 060574 During a recent adequacy test on the septic system for Lot 2 of Goodman subdivision, 67 and 70 inches of standing water was observed in the absorption fields. This indicates that approximately 95% of the absorption area is inundated. Although this system passed the adequacy test, the remaining life expectancy may be limited. This advisory must be attached to all copies of the subject Health Authority Approval. % The locution of the structure(s)as shorn on thi^ ec #roving (as• II)corn I',s L7itIe21,AMC. �r• 1 201 S 89'57'57" W 155.75' m 10' TELE ESMT. BK 770 PG 40 �d---- -------------------------= -:_.. --------------------------------- -------------------- ------ - tv TELE. at nZC. ESMT. 10' EACH SIDE P OF EXISTING ELECTRIC LINE O 0 z LOT 2 4 200 212 n' L- Z OF WAY C+ C) 0 o Ave. r, house ` sr.s o a; ,3 •'WiAYGii IC i�j • o 3BLM.'RO V. 4 200 212 n' L- Z OF WAY C+ C) 0 o Ave. r, 11-22-06:12:51 ; ;907 561 5301 # 2/ 4 SCS ROU ClIent Nome Project Name/M Client Sample ID Diatrix Samale Rcmarks: 1066710001 Anderson Engineering 3231 Dora Ave 3231 Dora Ave. Drinking water All Dalcc/rimca ore ALtslw Standard Time Printed DateMme I IR0/2006 8:05 Collected Date/time 11/08/2006 10:23 Received Date/Time 11/08/2006 10:42 Technical Director Stephen C. Ede Allowable Prep Analysis Parometr Rcsola PpL Units Method ContainerlD Limiu Data Date Inh Metals by ICP/MS Arsenic 22.8 • 5.00 uwt EP200.8 C (<10) 11/09/0611/13/06 TK Waters Department Nitrate -N ND 0.100 Microbiology .Laboratory Total Coliform 0 mWL EPA 3532 D (<I0) 11/10/06 ALR coV100mL SM2092223 A (<I) 11/OVD6 DPT