HomeMy WebLinkAboutSEABREEZE LT 3eabreeze Lot 3 #020-291-60 "EXPIRED" MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water d Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Upgrade Date Issued: Feb 12, 2008 Expiration Date: Feb 11, 2009 Permit Number. SW080009 Parcel ID: 020-291-60 Legal Description: SEABREEZE LOT 3 Design Engineer: 0855 GARNESS ENGINEERING GROUF Site Address: 18940 VILLAGES SCENIC PARKWAY Owner Name: DOUG SHAFFER Lot Size: 49730 SQ. FT. Owner Address: 121 OCEAN PARK DRIVE Total Bedrooms: 3 Permit Bedrooms: 3 ANCHORAGE. AK 99516 - This permit is for the construction of. ❑V Disposal Field Z✓ Septic Tank ❑ Holding Tank ❑ Privy Private Well E] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received Date: a �� Date: 8 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program ` 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519.6650 www.muni.org/onsite (907)343.7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. CL40 - �q I- (aD Property n n _ phone Mailing address 1>1 �(f� cln /' f YJh �� Zip Code q 95l5 Site address ) M'4z) �f li a -u g fru_ n{�jZip Code 9�1 SSG Legal description (Sub'd., Block & Lot) 2)J-4 Legal description (Township, Range & Section) Lot Size_ t -i R`g 30 Sq. Ft. THIS APPLICATION IS FOR (® all that apply): Absorption Field ©- Septic Tank 9 - Holding Tank E3 Privy n Private Well Q' Water Storage El Number of Bedrooms THIS APPLICATION IS AN: Initial El Upgrade 13 Renewal 13 I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. y (Signature of property or authorized agent) Permit/Rush Fees: l)15 Waiver Fees: Date of Payment: I/�&�� Date of Payment: Receipt Number. l ocip <9 U Receipt Number. (Rev. 11/05) MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 6 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Permit Number: SW070001 Legal Description: SEABREEZE LOT 3 Design Engineer: 0855 GARNESS ENGINEERING GROUF Owner Name: DOUG SHAFFER Owner Address: 121 OCEAN PARK DRIVE ANCHORAGE, AK 99516 - Date Issued: Jan 08, 2007 Expiration Date: Jan 08, 2008 Parcel ID: 020-291-60 Site Address: 18940 VILLAGES SCENIC PARKWAY Lot Size: 49730 SO. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of. ❑✓ Disposal Field [✓ Septic Tank Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Date: -7 Issued By: Date: . /e/ Municipality of Anchorage ✓ai �"rye Development Services Department Building Safety Division Onsite Water & Wastewater Program 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ek.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel LD Property owner(s) DOUG SHAFFER Day phone 227-4983 Mailing address 121 OCEAN PARK DRIVE • ANCHORAGE. AK 99515 Site address 18940 VILLAGES SCENICPARKWAY • AN HORA AK Zip Code 99516 Legal description (Sub'd, Block & Lot ) SEABREEZE: LOT 3 Legal description ((Township, Section & Range) —N/A Lot Size LM. 7 20 Sq. Ft. Number of Bedrooms 3 THIS APPLICATION IS FOR (®all that apply): Absorption Field Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well Water Storage ❑ THIS APPLICATION IS AN: Initial Upgrade ❑ Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. Permit/RushFees: /to0-C:0 / � Waiver Fees: _ Date of Payment: —� ;q/ d 7 Date of Payment: Receipt Number:Receipt Number. (Rw. 11/05) GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS r. December 11, 2006 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907)343-7904 Ref.• Proposed Well and Septic System for Seabreeze Subdivision; Lot 3 The proposed 3 bedroom house is to be served by a private well and septic system. The proposed well location is shown on the attached site plan and design drawings. We are proposing that a 1000 gallon septic tank and a 5 -wide trench type drainfield be installed. Two test holes were excavated on the property. The drainfield will be designed around the 30 foot radii of these test holes. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, and the percolation test results. 2. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. During our site visits, we found an area that was glaciating south of the proposed septic area with a drainage Swale, with no running water, running from east to west. Per the request of the owner, we have shown a proposed curtain/french drain in this area to insure this wet area will remain subsurface. There is no concerns with the installation of this curtain/french drain in regards to the proposed septic system. 3. TOPOGRAPHY: As can be seen on the attached design drawing, the average slope in the area of the proposed drainfield is approximately 10 to 15 percent running east to west. In short, there are no slope concerns. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. .. P.E., M.S. NOTE: A site plan drawing, a design drawing, soil logs, and a 7 page construction specification letter which are all part of the design package for this septic system. 3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507-1259 Ph: (907) 337-6179' Fax: (907) 338-3246 0 Website: www.gamcssenginecring.com \ L 1 • \ \� \ WELL IN NORTHWEST I THE VILLACES \ \ CORNER OF LOT �n1S/D; TRACT 11, \ 1 \ C � THE NL \ S/D: LOTOT. 1. t,. PROPOSED \ 1 \ C5[PTIC 1` SEPTIC SYSTEM \� \ ARLAD ® \ \ 1 • 100 11+11 • \�-s \ PROPOSED S BEDROOM HOUSE H/2 Y ` All 1 \ 1 / \ PROPOSED I I I \ I \ SEABREEZEI I CIACIATION \ \ J 1 \ SEABREEZE S/D; LOT 2.\ ` 1\ \ J \ \ /E / \ S/D: LOT 1. =I \ \ / NO WATER (FROZEN) \ \ THE VILLAGES i S/D; TRACT 13C. \ L _�- — - - —_ —_ _ _ THE VILLAGES =�---_ -- --S/D; TRACT 138. ARMC- J \ \ PROPOSED 0 SEPTICMTEM 0N� SOUTHSIDE OF LOT\ PROPOSED GARNESS ENGINEERING GROUP, Ltd,TANTS & GENERAL ( .11,44?.' r6LrMLU IUK: PHONE NUMBER: PACE NUMBER: DOUG SHAFFER 1 349-2229 1 1 OF 2 LEGAL DESCRIPTION: SEABREEZE SUBDVISION: LOT C OF WORK: SITE PLAN FOR PROPOSED WELL AND SEPTIC J.L.M. 1/06 e "IA. Gar ess: CE— :i •' ,dG p�0 /w�S10n�\ RIVER ROCK INSTALL 12 MIL GEOMEMBRANE BARRIER (RPE® 15)ON DOWNHILL SIDE OF DRAIN TUBE ORIGINAL GRADE POINT 10, DEEPRADLIALLYE , CST SHALLOW TO I 0' DEPTH AT EXISTING DRAINACE SWALE. SOLID 4' PIPE PERFORATED 6' PIPE —4' PERFORATED PIPE (SLOPED AT 37 TO DRAIN). GARNLSS LN(5iNTLL CONSULTANTS S GERING GROUP wog C nao� " NERAL CONTRACTORS— rrwr ..�,...,. ,., Ltd. euu, mi . ,vnc�,Y,l xi aurt PREPARED FOR: ^'� (ro'7snrin . ru fwrAvs-,uw • DOUG SHAFFER PHONE NUMBER: 227-4983 PACE NUMBER: LEGAL DESCRIPTION: 2 OF 2 SEABREEZ LOT 3 DRAWN Br: I1'PE OF WORK: P•N,B CURTAIN DRAIN DETAIL DRAWING DATE: 10/16/2007 co 0 .. ... e r y A. Gar ess.: g. CE/ -77953 i o011e„e.. lQ/'7• �01Z • c t�Ao% NO EPENDIN N HE ELEVATION OF THE LINE FROM THE HOUSE, A LIFT STATION MAY BE REQUIRED FOR ONE OR BOTH THE PRIMARY AND ALTERNATE R . NUMBER OF BEDROOMS:3 GALLONS PER DAY (CPD): 450 PERCOLATION RATE/S: 10-15 MIN./INCH PROPOSED APPLICATION RATE: 0.6 MINIMUM DRAINFIELD SO.FT.: 750 MAXIMUM DEPTH:7.5 FEET WIDTHS FEET LENGTH:75 FEET M.O.A. APPROVED SAND FILTER: N/A EFFECTIVE:4 FEET REDUCTION FACTOR: N/A ACTUAL SO.FT.: 750 ALTERNATE cu TH/2 \\ FCO F PROPOSED\ ,' 3 BEDROOM N HOUSE i RADII. AND ANY SURFACE WATER �• FLAGGED BY A REGISTERED LANE GLACIATION /(APPROXIMATE 1 LOCATION) 1� PROPOSED DRNNFlELp� I `l1 TM11 �I 1 �1 PROPOSED CURTUW DRAIN OBTAIN A COPY THE LETTER CLEANOLINSTALL A LE ST ST 1 'ROPOSE 1000 THIS INNSTALLj TION. THE RD cu TH/2 \\ FCO F PROPOSED\ ,' 3 BEDROOM N HOUSE i RADII. AND ANY SURFACE WATER �• FLAGGED BY A REGISTERED LANE GLACIATION /(APPROXIMATE 1 LOCATION) 04�.-..j GARNESS ENGINEERING GROUP, Ltd. p, CONSULTANTS b GENERAL CONTRACTORS �••••••• 3MI L TM100 IKAA FNM 101 • AWM%WL MI 0M.0Y ACOS W7)=iJn • FN[ (001)Slh 0®tC• �w.p�.yrlyyn O IPREPARED FOR: PHONE NUMBER: PACE NUMBER: DOUG SHAFFER 227-4983 2 OF 2JE LEGAL DESCRIPTION: DRAWN BY: OQOa SEABREEZE SUBDIVISION; LOT 3 J.L.M. 4� TYPE OF WORK: DATE: 1 DESIGN FOR PROPOSED WELL AND SEPTIC SYSTEM 12/11/2006 ...... ....... A. Gor ess: 1. HAS A 7 PACE4 LETTER THAT PERTAINS TO THIS DESIGN. PROPOSED CURTUW DRAIN OBTAIN A COPY THE LETTER WITH FRENCH DRAIN FROMTO CONTACT CE GENGINE FOUNDATION DRAIN TIED INTO R. THIS INNSTALLj TION. THE RD WELL DRILLER. CONTRACTOR AND PROPERTY OWNER AGREE THAT THEY HAVE READ THESE SPECIFICATIONS AND - EXISTING DITCHUNE AGREET ACCEPT THE TERMS AND (APPROXIMATE LOCATION) , CO ORIONS OUTLINEO. 04�.-..j GARNESS ENGINEERING GROUP, Ltd. p, CONSULTANTS b GENERAL CONTRACTORS �••••••• 3MI L TM100 IKAA FNM 101 • AWM%WL MI 0M.0Y ACOS W7)=iJn • FN[ (001)Slh 0®tC• �w.p�.yrlyyn O IPREPARED FOR: PHONE NUMBER: PACE NUMBER: DOUG SHAFFER 227-4983 2 OF 2JE LEGAL DESCRIPTION: DRAWN BY: OQOa SEABREEZE SUBDIVISION; LOT 3 J.L.M. 4� TYPE OF WORK: DATE: 1 DESIGN FOR PROPOSED WELL AND SEPTIC SYSTEM 12/11/2006 ...... ....... A. Gor ess: GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS& GENERAL CONTRACTORS 701 L IUOpI IIMO, $LM 101 • NKIKNA"F A ROW7 PgMG 00> )-4179 • Fw 007 N" • ;5VT ,v.w-pw SOIL LOG — PERCOLATION TEST LEGAL DESCRIPTION: SEABREEZE S/D: LOT 3 PERFORMED FOR: DOUG SHAFFER DATE: 11/10/2001 DEPT; ____ ORGANICS feet TEST HOLE 1 t 7 8 9 10 11 12 13 14 15 16 17 18 GM DEPTH TO DATE GROUNDWATER DRY 1/10/200 DRY 1/20/200 THI1+ N Tl i `t GLACIATION ; 1 t I ; I SEABREEZE It 5/D: LOT 2. OrtCHUNE 1 1 NO WATER SCALE: (FROZEN) DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING CLASSIFICATIONS 11/13/2006 1 3:00 rrSOIL 6- rGW 3:30 30 3- 3- 3 3:30 .- 6- — 4 4:00 - ��ititittML 4- 2- r 4:30 r it�tu-ilGMiiia.CIL — 6 r 30 4- G%/i HNN • r 111111111 MH - iCH r r ��I�iti • sc 7 8 9 10 11 12 13 14 15 16 17 18 GM DEPTH TO DATE GROUNDWATER DRY 1/10/200 DRY 1/20/200 THI1+ N Tl i `t GLACIATION ; 1 t I ; I SEABREEZE It 5/D: LOT 2. OrtCHUNE 1 1 NO WATER SCALE: (FROZEN) DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 11/13/2006 1 3:00 — 6- — 2 3:30 30 3- 3- 3 3:30 — 6- — 4 4:00 30 4- 2- 5 4:30 — 6- — 6 5:00 30 4- 2- 19� PERCOLATION RATE 15 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 4.0 FT. AND 5.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO SOILS LOGGED BY: CALEB CALL PERCOLATION TEST PERFORMED BY: BENNY MAUS COMMENTS: PERFORMED BY GEC, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PE FORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 1 Z oL GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS SOIL LOG — PERCOLATION TEST LEGAL DESCRIPTION: SEABREEZE S/D; LOT 3 PERFORMED FOR: DOUG SHAFFER DATE: 11 DEPTH ORGANICS (feet) ---- TEST HOLE 2 1 7 8 9 10 11 12 13 14 15 16 17 18 GM DEPTH TO GROUNDWATER •SOIL DRY 11/10/2006 CLASSIFICATIONS 11/20/2006 3:00 TH/'1 6- t 2 1 30 TM12+ 5- 3 GW •. 6' jGP111111111ML 4 4:00 30 3' 3- t 4:30 — II.111.11GM%//%CL — 6 GLACIATION ; 3- GCNNH • tSW ; IIIIIIIII MH SEABREEZE S/D; LOT 2, _ CH NO WATER SCALE: / SM OH 7 8 9 10 11 12 13 14 15 16 17 18 GM DEPTH TO GROUNDWATER DATE DRY 11/10/2006 12.5' 11/20/2006 3:00 TH/'1 6- of �7 N DATE READING 1 NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 11/13/2006 1 3:00 TH/'1 6- of �7 N 2 1 30 TM12+ 5- 3 3:30 — 6' — 4 4:00 30 3' 3- 5 4:30 — 6' — 6 GLACIATION ; 3- 1 1 1 ; I SEABREEZE S/D; LOT 2, DRCHUNE NO WATER SCALE: / (FROZEN) 1' y 100' DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 11/13/2006 1 3:00 — 6- — 2 3:30 30 1' 5- 3 3:30 — 6' — 4 4:00 30 3' 3- 5 4:30 — 6' — 6 5:00 30 3- 3- 19 I I PERCOLATION RATE 10 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) —ll—lll TEST RUN BETWEEN 4.0 FT. AND 5.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: 0 YES ❑ NO SOILS LOGGED BY: CALEB CALL PERCOLATION TEST PERFORMED BY: BENNY MAUS PERFORMED BY GEG, Ltd. 1, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS P RFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: si06 _