Loading...
HomeMy WebLinkAboutEATON PARK LT 11Eaton Park Lot i l #051-111-79 Municipality of Anchorage'`' Development Services Department i Building Safety Division On-Site Water and Wastewater Program, 4700 S. Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page of www.d.anchorage.ak.us (907) 3417904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SWO50130 PID Number. - 1 M,n. LH Construction, Inc. Wastewater System: El New ❑ Upgrade A": 12130 Regency Dr.: Eagle River, AK 99577 ABSORPTION FIELD PtVW, Ml.ln« a aeaeemF (907) 522-1616 4 O DespTarcn p swwTlMlal pew pM«.a ❑om.c LEGAL DESCRIPTION ew RMn9 0.7 Tar DOW IMI aq.W an" 9.0 GPD/Fe Ft. It Y Ld'. 11 alcenMa,: Eaton Park DWM b PPS tXXI" IMI OrVW pwe: Gn aspen e«a.m9 6.1 R. FI TowwwRni7e. $s : 15N 1W 10 Fi wosa eoPre ay. WW Qwe. Gm LVVIX 60 5.0 Ft. Ft. Well: ❑D New [3 Upgrade Glewi Man: 15 Rlmo.r a raF: 4 QMMKe 4 Ft Ft CISMI,nron JP . A S. C1: Tar Dem. GMa n: Tar nee P" MMenr. Private 246 Ft. Ft goo Ff 4- PVC (ASTM D-3034) Darr A&L Drilling Company OM Da St p Ww L"i `F* �ekrMwa mMrwr LH Construction, Inc. 12/12/05 1965 Ft. Y WO. 10 Puny $al M. G—V H-V � Gloua. TANK GPM Unknown FL 2 FL SEPARATION DISTANCES Elseptic ❑Holding ❑S.T.E.P. ❑Other: To Septic Absorption lift Holding ublWPMate ea«M` t' From Tank Field Station Tank Sewer Lina Anchorage Tank & Welding 1250 Gr ww 100' 113' N/A N/A 46' M.Lnr. Steel Nuro«aCanprmrae. srwwM« +150' +150' N/A NIA LIFT STATION ea«« La Lxa 60' 35' N/A N/A N/A GM 'Pune of N.rr 'P«ep WMrel« Pgn wel«ewlm a. Faeralan 57' 73' N/A N/A M M ti N/A N/A NIA N/A Faro Mare 6 Moots Ew impa pw«naa M c M.M o .a It � Area not landscaped at the time of the as-built BENCH MARK survey. Louuon rr DeMTPIgn. Top of Lot 11 Well Casing. .� 100 FL OVInee(s Stamp-!Z, tT H`Z' ' • 9 Inspections performed by: Russell Hepner, E.I.T. Dates: 1M 12/6/05 2ne 12/12/05 `� '•;Allan . Murfitt.'w Developmen Services Department Approval 4977-E 1 f,Q'•. Reviewed and approved by: Date: �I 2t oQ' c� 4... j b....*' ° a n to 12M)""I' . EsSic� �6 . .. W, .r SYMMETRIC ABOUT C.L. 4' SWEEP CLEENOUTS WITH CAPS. MONITOR TUBE —� I FILTER FABRIC i 10.6' BUILDING T 1 FOUNDATION —rr 4' PERF. PIPE CO i I 57' I 'ROCK 0.9' 2 NEW 1250 -GAL 2 COMPARTMENT I FILTER SAND BED 2' STEEL SEPTIC 30 TANK 4 5 20• 6 No GW To 15' below Original Grade BED SECTION _N TS r --rte CLEANOUTS (TVP) F2' BOTH ENDS I PF 4' SWEEP CO I� TOWARDS TANK —{ 1.50 rT. TYPICAL II TEST HOLE i i I I � I 4' MONITOR TUBE. i PLAN 15' x 60' BED 14737 4"x 56' PERF. PIPES LAID LEVEL 4 PIPES AT 4 -FT CENTERS. Notes: 1. No neighboring septic systems, wells, or bodies of water are located within 100' of this system. 2. On -lot well is 100' from the septic tank. 3. All pipe is 4" PVC (ASTM D-3034) with 4" perforated PVC used in the wide drainfield. 4. No driveways on / over septic system. 10 Allan W, t:iu' fitt NO,4977-E 1, Loonsuning tngineers ano i esung 4 PLATE A. W. Murfitt Company L H Construction, Inc. 1 Septic As -Built 13810 Ven us ay c ora e, 51 Lot 11, Eaton Park Subdivision 907 34usW Fax: 90 345-3264 Job No. 06-394.14 Date: 7/25/06 Drawn: RH Chugiak, AK Elevation based on assumed well casing elevation of 100.00'. "Invert measured from top of stickup Stickup Invert" Cover Top of Pipe Elevation' Invert Ground Water Well Casing 1 CO 3.3' 100.00' 2 ST 58.7' 1 (CO) 19.5" 78.25" 58.75' 99.05' 92.52' 97.42' N/A 2 (ST) 13" 156.25" 85.25" 99.41' 86.39' 98.33' N/A 3 (ST) 10.25" 163.75" 95.5" 100.15' 86.51' 99.30' N/A Tank Inlet 9 CO 115.5' 146.7' 90.64' CO 111.8' Tank Outlet 11 CO 110.5' 142.9' 90.59' MT 97.1' 4 (CO) 8.5' 121.5" 113" 100.28' 90.15' 99.57' N/A 5 (CO) 10.5' 125.75" 115.25" 100.42' 89.94' 99.54' N/A 6 (CO) 8.75" 132.75" 124' 100.93' 89.87' 100.20' N/A 7 (CO) 9.5" 136.75" 127.25' 100.97' 89.58' 100.18' N/A 8 (CO) 10.5" 151" 140.5' 101.81' 89.22' 100.93' N/A 9 (CO) 11" 148" 137" 101.66' 89.32' 100.74' N/A 10 (CO) 14.25" 146.75" 132.5' 101.69' 89.46' 100.50' N/A 11 (CO) 11.5" 143.75" 132.25" 101.32' 89.34' 100.36' N/A 12 (MT) 8" 171.5" 163.5" 100.77' 86.48' 100.10' N/A Elevation based on assumed well casing elevation of 100.00'. "Invert measured from top of stickup PLATE 3 S nq Ties .A. .8. 1 CO 3.3' 37.1' 2 ST 58.7' 71.9' 3 ST 67.5' 79.8' 4 CO 69.5' 81.8' 5 CO 70.9' 83.0' 6 CO 75.2' 87.4' 7 CO 81.2' 101.1' 8 CO 117.9' 148.2' 9 CO 115.5' 146.7' 10 CO 111.8' 144.6' 11 CO 110.5' 142.9' 12 MT 97.1' 125.4' PLATE 3 4 / 00 C LOT 11 40.M 0. 15' TELECOM do � \ \ ELECTRIC EASEMENT/' 7Ej\ \ 00' N 89'42'04'E 86.30' 2.0' CANT— — L\ -42.4"'X ` 4 �1 A' GNr SA' CIJIt 2$ x ii.j• Or. SEPTIC CLEANOUTS F'• 4..' h9- . 9 9 (EST qot� 47- `i' '.Allan W. Murfit' W a d i 477E TRACT 3 GLOP A42UNTN# SLW PLOT PLAN AS BUILT X SCALE –1:-- 40' GRID NIM 1361 Project No. 05-097 Lan & Associates, Inc. 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang 907) 522-6476 Phone Registered Land Surveyors 907) 522-4625 Fax ! OF A k9longle0olaska.net / jolongis0alaska.net .<`........... .s I hereby certify that 1 haw surveyed the following described property. �Q LOT 11. EATON PARK SUBDMSION (PLAT No. 2005-52) Ar 49IB �* Anchorage Recording District, Alaska, and that the Improvements situated thereon are ••.... within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed '.. promises and that there are no roadways, transmission lines or other visible KENNETH G. easements on sold property except as Indicated hereon. Q " –5202 Dated this the 243' Day of LAI 14 'LOoC. at Anchorage, Alaska U`1�06 N Is the responsibility of the owner to etermine the existence of any easements, 'b, covenants. or restrictions which do not appear on the recorded subdivision clot. PIA�E 2 •A• .3. 3.3 37.1 2 69.7 71.9 3 N. 9.0 4 69.5 81.6 5 70.9 63.9 6 75.2 07.4 7 61.2 101.1 6 117.9 148.2 9 116.6 149.7 10111.6 +/ 110.6 12.9 TRACT 3 GLOP A42UNTN# SLW PLOT PLAN AS BUILT X SCALE –1:-- 40' GRID NIM 1361 Project No. 05-097 Lan & Associates, Inc. 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang 907) 522-6476 Phone Registered Land Surveyors 907) 522-4625 Fax ! OF A k9longle0olaska.net / jolongis0alaska.net .<`........... .s I hereby certify that 1 haw surveyed the following described property. �Q LOT 11. EATON PARK SUBDMSION (PLAT No. 2005-52) Ar 49IB �* Anchorage Recording District, Alaska, and that the Improvements situated thereon are ••.... within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed '.. promises and that there are no roadways, transmission lines or other visible KENNETH G. easements on sold property except as Indicated hereon. Q " –5202 Dated this the 243' Day of LAI 14 'LOoC. at Anchorage, Alaska U`1�06 N Is the responsibility of the owner to etermine the existence of any easements, 'b, covenants. or restrictions which do not appear on the recorded subdivision clot. PIA�E 2 Municipality of Anchorage Development Services Department Building Safety Division �• On Sita Water and Wastewater Program 4700 South Bragew Sl. P.O. Box 196650 Anchorage. AK 995146650 yAvw, muni mlonsite (907) 343-7904 Soils Log - Percolation Test .ti S�r(ENGINEER'S SEAL),;,..�� LJ � PeAomled For: VA Date L.` ` Dete PeAwmad: i�y&pO Legal Detwripnon.•9� : \\\ \ FC.Xb� QV-r\k ��ber�. Township. Range. Section: Nin`, Se,-\%. T\5y% Q\W�SM.,v Depth 3041 1- ii Ia 2- 3- 4- -3-4- i e i v 39 1 5- a. i34s 6-!ia• tail T- aia� Tsai La•i 9- Dale C _ 6, WASGROUNDWATER ENCOUNTERED? Net Time Depth to Water a to- S/11 0 IF YES. AT WHAT DEPTH? L e Depen to Water Altar a Mondtwing? E 12- Date: COMMENTS r Reading Dale Gross Time Net Time Depth to Water Net Drop (0 1# S/11 0 S`.31PM nrn Is -VA � O PERCOLATION RATE C (minutes6nch) FERC HOLE DIAMETER (o •• TESTRUNBETWEEN ,.j FT AND _FT ♦. . r s , i . 3 \ T4 PERFORMED BY: q u%%& \\ caH�cd t- .Z.: �. I w\.,,n W , �,ir4'�� e1?s, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WIT ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: tN[&, _ \(S l jk,�j�a 4 MARK HANSEN P.E. CONSMING ENGINEERS TESTING LABORATORY P.O. Lox 4723 Pdmr. AN 99643-4323 Phan. (907) 743-4721 Fox: (907) 745-4721 �11; mhp.wntoonnnan.t Alaska Gravel Products PO Box 4343 Palmer, AK 99645 Fax 745-4454 Project: 2005 Materials Testing Subject: Sieve Analysis, Filter Sand Gentlemen: June 28, 2005 ' Work Order: 0507 The following is the sieve analysis of the aggregate sampled on 6/28105. Sample Location: stockpile Sieve Passing MOA Spec. 1/2" 100% 3/8" 100% #4 100% 100 #10 78% #20 57% #40 30% #60 9% #100 2°% 0-2 #200 0.7% 0-1 The sample conforms to MOA specifications for filter sand. If you have any questions, please do not hesitate to call. Sincerely,/� Mark Hansen PLP�E 4 MAY -11-2005 03:35P FROM: 70:3453264 P:3 LOG OF DRILLING by A OWNER Or LAND ADDRESS._.__,.C__......_._�____M_...._.__.._«___.._�...� WELLsm.�C Novo L07 FII L' 6 oa F�pgwl L DRILLING COMPANY DEPTH Or STATIC LrVrL Or WATER rT. DRAW DOWN FT DATr.JSTARTED...... GALS. PLA HII. .._.Q=E OM.4.........�._. DATE—,ENDED .-._..��5_....�._«_..._._._.__.....» MIND Or CASINO ._..._.. ...__...__.._..... ELMS Or rOILMATION. rr.TO....1_.___t-r_LI_�tt/_cr.;. rAOM.._..L.L.___...rT. r0.__ � j._.___r•s'.„ w e t_S..0.a J rAOM.�.:.� _..._...FT. TO_ iE_.....__-TT.._� /wY...._._�.0.• �!•'frAOIL.. � !y_...FT. TO__..�.._4 y .__ST...S._!t.^..�..._.... FROM_:f f_._._.__7T. TO__ � �....--.FT__»�L.t•. �....: �••�•;/ rROM,_�. �I.= � SI. TO.._ 3 3.i ._..T`1' /Y t. r �l,,te.. FROM. -2.)X__—rT. TO ... / %...._ FROM. I..�-.z .__.rT. TO._..!. Z.y.___.PI'._._f�..r✓.%/, j w r�1FIlOM_____.._.___....iT. To ....... MISCL. INFORMATION: DRILLEA'S NAME TP/791 WWA N"AT-rM r.Gr.7,RR4 rP:PP AAr,?fIP/TP MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water b Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519.6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Permit Number: SWO50130 Legal Description: EATON PARK SUBDIVISION LOT 11 Design Engineer: 0009 A.W. Murfitt Company, Inc. Owner Name: L.H. CONSTRUCTION Date Issued: May 18, 2005 Expiration Date: May 18, 2006 Parcel ID: 051-492-58 �'X134✓d, Site Address: E Lot Size: 0 SQ. FT. Owner Address: 12130 REGENCY DRIVE Total Bedrooms: 4 Permit Bedrooms: 4 EAGLE RIVER. AK 99577 - This permit is for the construction of: ❑✓ Disposal Field ❑� Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be In accordance with: 1. The attached approved design. 2. All requirements specked in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Date: Issued By. Date: Municipality of Anchorage Development Services Department Building Safety Division \, On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. /`'`3 44 y rl " 6 Z's8 Permit Number SW Property phone � -::1 "7(. /G Mailing address Zip Code Site address Zip Code Legal description (Lot, Block & Sub'd.) LTPnt1 l/ 14 K L07 - Legal description (Section, Township & Range) -7_ Sf"i21 W SCC- Ib N E 1/4 Lot Size �W)Iq3 ___�Acret'Flj Number of Bedrooms 4 THIS APPLICATION IS FOR: Sewer Only ❑ Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: i4frn -2 Waiver Fees: Date of Payment: 571 P -AD 6- Date of Payment: Receipt Number: G���O Receipt Number. (Rev. 09104) A.W. Muwrfitt Company_ CONSULTING ENGINEERS & TESTING 13810 Venus Way • Anchorete, Alaska 99515 • Tek-phom (907) 345.2737 • FAX (907) 345-3264 September 15, 2005 Municipality of Anchorage Department of Health & Human Services On -Site Services P.O. Box 196650 Anchorage, AK 99519-6650 ATTENTION: Mr. Joe Goodall Civil Engineer RE: Eaton Park Septic Systems Lot 11 NEI/4, T15N, R1W, Sec. 10, S.M., AK Chugiak, Alaska AWM Co. Job 05-394.14 Dear Mr. Goodall: We are in receipt of your telephone directive of August 31, 2005 (inspection letter request) and email of September 8, 2005 regarding the status of the septic designs on the referenced properties. This letter has been prepared in response to your determination. Mr. Ken Lang, R.L.S. the project survey and I made a site visit on Thursday evening September 8, 2005 to establish the exact locations of the septic systems designed for Lots 9, 10, and 11. These locations were surveyed as shown on our design documents. We have determined that the accepting soils used in our designs are in fact still in place. Soil percolation tests were done at depths of 4.5 to 5.5 feet and all resulted in a rate of less than one minute per inch. You will note that the proposed systems are located near the fronts of the lots at 9 and 10 (soil in place) and to the rear at Lot 11 where soil was removed (4 to 6 feet). The existing soil surface (sandy gravel) would be the approximate bottom of the sand filter bed where the percolation test was done. Similarly, the same condition at Lots 9 and 10 (excavated partially at 4 to 5 feet) exists. Septic systems had to be located in these areas due to slope conflicts in the rear of the properties and protective well radii. Septic locations are very limited and digging new test holes will destroy additional septic area. Test pits for this work were dug to depths of 15 to 17 feet, no ground water or impermeable layers present. The well logs for Lot 9 and 10 shows sand /gravel to depths of 35 and 41 feet with static water levels at 185 and 175 feet, respectively. The Lot 11 well was drilled in 1965 with the current static water level at 173.6 feet. Geologically, the near surface soil at the lots is homogeneous and consistent over the first 35 feet with no groundwater or impermeable layers. Note aquifer testing was done in the subdivision development/approval process for which the MOA has this documentation (Aquifer Test Report, dated April 4, 2005 by Anderson Engineering). The designed system locations will be re-established by survey prior to construction. Construction of the piping Page 2 September 15, 2005 05-394.14 Eaton Park Lot 11 and beds will be difficult in that the upper 4 to 5 feet of backfill soil is gone. The sand filter can be placed directly on the natural sandy gravel and the total installation (piping, bed, tank) protected with a fine soil bedding/padding adequately compacted. Bed accepting soils will be verified and re -percolated if necessary and the whole backfilling operation closely scrutinized by our engineering staff. We understand that the contractor plans to use the sandy gravel embankment material in the rear of the properties for final grading to the required cover depths of our design. We hope that the foregoing will reverse your determination on the referenced septic systems. Please do not hesitate to call if you have any questions, or we can be of additional assistance in this matter. Sincerely, Murfitt Company Allan W. Murfitt, P.E. Registered Civil Engineer 4977-E Attachments: Well logs. Copy to: LFI Construction, Inc. A.W. Murfitt Company_ CONSULTING ENGINEERS &. TESTING 13810 Venus Wap • Anchorage, Alaska 99515 • Tekpho (907) 345.2737 • FAX (907) 345-3264 May 11, 2005 Municipality of Anchorage Department of Health & Human Services On -Site Services Section 4700 South Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 ATTENTION:Mr. Jim Cross, P.E. RE: Septic System Design Four Bedroom, Single Family Dwelling Lot 11, Eaton Park Subdivision NE %., T15N, R1W, Sec.10, S.M., AK. L H Construction, Inc. Chugiak, Alaska Our Job 05-394.14 Dear Mr. Cross: The referenced property represents an undeveloped 40,073 square foot parcel. The proposed four (4) bedroom, single family dwelling is shown on the attached site plan, Plate 2. Our design data is summarized in the following dialog. SOILS: Attached is a copy of the soil log/percolation test data, Site Plan and Soil Particle Size Distribution Report. The log documents a well -graded Gravel (GW) with Sand and Cobbles soil profile to a depth of 15 feet below the ground surface. No water table was encountered with monitoring through 3/21/05. The receiving soil has a percolation rate less than one (1) minute per inch. A filter sand is required to slow the absorption rate. 2. BED DRAIN FIELD DESIGN: a. Percolation Rate: greater than 1 minute per inch with filter sand (CPP Palmer, T & J Services Wasilla). b. Allowable application Rate: 0.7 gallons/day/R? c. Number of Bedrooms: 4. Page 2. Lot I 1 Eaton Park May 11, 2005 05-394.14 d. Design Flow: 600 gallons per day (at 150gallons/bedroom). e. Minimum Absorption Area: 858 s.f. f. Maximum Total Depth (below original grade): 8.0 ft. (4'— 2" cover, 1.0 ft. sewer rock, 2.0 feet filter sand). g. Width: 15 ft. h. Minimum Length: 60 feet. i. Effective Absorption Area = 900 s.f. 3. SURFACE WATERS: There are no surface waters within 300 feet of the proposed septic system. There are no streams or drainages on the property. 4. TOPOGRAPIiY: The septic site slopes to the north at 3 to 5, percent. No 25% slopes exceeding in the immediate area. 5. IMPACTS: On the basis of our site visit and the available site information, there are no current well and septic developments within 100 feet of this system. Accordingly, there will be no adverse impacts on adjacent wells or septic systems of adjacent lots when built as designed. 6. WELL and SEPTIC INSTALLATION: The well installation was completed in 1965 by A & L Drilling Company (copy of well log attached). The septic system designed herein shall be constructed in accordance with the most recent AMC 15.65 by an approved septic system installer. The installations shall be completed in accordance with the requirements of the On Site Well and Septic Permits. The overall Eaton Park development plan has already been submitted to DHIIS but a copy is attached for information. Page 2. Lot 11 Eaton Park May 11, 2005 05-394.14 Please call our office at 345-2737 if you have any questions or need additional information. Sincerely, A.W. Murfitt Company .�:^��, r Allan W. Murfitt, P.E. I Allan W. ldurfi .'-w Registered Civil Engineer 4977-E sif. NO 4977-E COPY TO: LH Construction, Inc. Mr. Mike Irving ATTACHMENTS: Percolation Test Report, Bed Drain Field Design Plate 1, Site Plan Plate 2, Soil Particle Size Distribution Report Figure 1, and Well Log. Municipality of Anchorage Development Services Department Building Safety Division yr On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Boa 196650 Anchorage, AK 99519-6650 vAyw muni omronsilq (907)343-7904 Soils Log - Percolation Test Performed For: Thomas Development, Inc. Dale Performed: 3/2/2005 Legal Description: Lot 11, Eaton Park Subdivision Township, Range, Section: NIA IW, Scc. I0. T15N. RI W, S.M.. AK Slope Site Plan Depth (Feet) / 1t Well -graded Gravel with 1'i 1 2 1 R'a Sand and Cobbles (GW), /141 3- 1.11/ brown, moist 117111 <- 12'0 .3 s,i es 5- 1 i'1 t 6 1 %* 1 Seasonal frost to 5.5'. 111 1 7- i 1r11 g 17,11 i• •v - .....'='-c 10-iaL I 17- 18- 19- 20- Y �'z • 4 �Y .wR• I Depth 15' H 5 JNTEREDT No s W WIT DEPTH? L r Water After 4tonng? NONE Date 3-11-05 a Reading Date Gross Time Net Time Depth to Water Net Drop 6" /2/05 2:58 pm 0 0" 2:59 prn I min 6- 6- 3/2/05 3:00 prn 0 0" 3:01 Prn I min 6" PERCOLATION RATE < I (minutosAnch) PERC HOLE DETER 6" TESTRUNBETWEEN 5.5 FT AND 6 FT COMMENTS PERFORMED BY: Russell Ilepner, E.I.T. I Allan W. Mutt CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: March 2.2005 Q 1a 9C 7( W 6( 2 LL Z Z W U (Lai 31 21 11 Particle Size Distribution Report r GRAIN SIZE - mm %COBBLES %GRAVEL %SAND %SILT Y. CLAY 27.3 4.0 SIEVE SIZE PERCENT FINER SPEC.' PERCENT PASS? (X -NO) 2 in. 75A Coefficients 1.5 in. 70.8 101 ON D50= 12.5 11111111111 67.6 MINIMUM Cu= 38.22 .75 in. 1111110 iiiiiiniallillimil liiiiiiiniiiiiiiisillillimillillin Classi0eatlon .5 in. millillilmilillilloililillol 1111111110111111 375 in. 44.8 Natural Moisture 2.6%. HIRE 313 M1II11111 HIRE 11111111 182 #20 12.3 #40 8.7 #60 6.5 #100 5.3 #200 4.0 GRAIN SIZE - mm %COBBLES %GRAVEL %SAND %SILT Y. CLAY 27.3 4.0 SIEVE SIZE PERCENT FINER SPEC.' PERCENT PASS? (X -NO) 2 in. 75A Coefficients 1.5 in. 70.8 D60= 21.0 D50= 12.5 1 in. 67.6 D70= 0.549 Cu= 38.22 .75 in. 562 Classi0eatlon .5 in. 50.2 AASHTO= 375 in. 44.8 Natural Moisture 2.6%. #4 313 #10 182 #20 12.3 #40 8.7 #60 6.5 #100 5.3 #200 4.0 Material Description Wcll-graded Gravel with Sand (GW). (no spwficatiun provided) Sample No.: 3 Source of Sample: Date: 3/2/05 Location: Lot I 1 Test Pit #2 ElevJDepth: 5.5-6 AW M u rf itt Client: Thomas Development Eaton Park Project: Lot 11, Eaton Park Subd. Pcrc. Tat Pits Com an Proles: No: 04-449.03 Figure 1 Atterber0 Limits PL= NP LL= NV PI= Coefficients D85= D60= 21.0 D50= 12.5 D30= 4-42D 137 D70= 0.549 Cu= 38.22 Cc= 1.69 Classi0eatlon USCS= GW AASHTO= Remarks Natural Moisture 2.6%. (no spwficatiun provided) Sample No.: 3 Source of Sample: Date: 3/2/05 Location: Lot I 1 Test Pit #2 ElevJDepth: 5.5-6 AW M u rf itt Client: Thomas Development Eaton Park Project: Lot 11, Eaton Park Subd. Pcrc. Tat Pits Com an Proles: No: 04-449.03 Figure 1 SYMMETRIC ABOUT C.L. MOUND KFILL TDCDRAIN MONITOR TUBE —� FILTER BUILDING T FOUNDATION co Sa' MIN 4" PVC (D3034) SLOPE 1/4 INCH PER FT. MIN. 0 NEW 1250 -GAL 2COMPARTMENT 0 STEEL SEPTIC TANK 3' MIN r --rte I I I I I I I I I I I I I I� I I I I I I I I I I V CLEANOUTS (TYP) F2' BOTH ENDS 4' MT MIDDLE OF FIELD. PERFS. IN SEPTIC ROCK, SOLID SECTION 1111 ABOVE. V PLAN 15'x 60' BED N. . 4"x 56' PERF. PIPES LAID LEVEL 4 PIPES AT 4 -FT CENTERS. A. W. Murfitt Compan (907)345-2737 Fax: (907) 345-3624 Job No. 05-394.14 Date: 5/09/05 Drawn: RH 4' SVEEP CLEENOUTS VITH CAPS. 4' MIN Y I IL-4' PERF. PIPET T lr"y _ 1 FT. SEPTIC ROCK PER 6, MOA SPEC. S FILTER SAND BED 2 FT. PER MOA SPEC.'S , No GW To 15' BED SECTION N.TS Notes: 1. No neighboring septic systems, wells, or bodies of water are located within 100' of this proposed system. 2. On -lot well to be 100' min. away from system. 3. System 10' min. from property line set back. 4. All pipe is 4" PVC (ASTM D-3034) with 4" perforated PVC used in the wide drainfield. 5. All distances shown on the above drawing are minimum for construction of the septic system. 6. Insulation required with 4' or less cover. 7. System to be installed by MOA certified installer. 6. Two (2) inspections are required by a Registered Civil Engineer. 9. No driveways on / over septic system. 10. 0.92 acre site undeveloped. �.�\\• ;49Nv*l �MURFlTT: 4977 ; �• 1/f/J74 o_ r."•cS�� It lk-W �. PLATE L H Construction, Inc. Septic Lot 11, Eaton Park Subdivision Chugiak, AK 4'SWEEPCO II TOWARDS TANK —{ II 1.50 FT. TYPICAL TEST PIT I I I I � (CENTER) I I I 4' MT MIDDLE OF FIELD. PERFS. IN SEPTIC ROCK, SOLID SECTION 1111 ABOVE. V PLAN 15'x 60' BED N. . 4"x 56' PERF. PIPES LAID LEVEL 4 PIPES AT 4 -FT CENTERS. A. W. Murfitt Compan (907)345-2737 Fax: (907) 345-3624 Job No. 05-394.14 Date: 5/09/05 Drawn: RH 4' SVEEP CLEENOUTS VITH CAPS. 4' MIN Y I IL-4' PERF. PIPET T lr"y _ 1 FT. SEPTIC ROCK PER 6, MOA SPEC. S FILTER SAND BED 2 FT. PER MOA SPEC.'S , No GW To 15' BED SECTION N.TS Notes: 1. No neighboring septic systems, wells, or bodies of water are located within 100' of this proposed system. 2. On -lot well to be 100' min. away from system. 3. System 10' min. from property line set back. 4. All pipe is 4" PVC (ASTM D-3034) with 4" perforated PVC used in the wide drainfield. 5. All distances shown on the above drawing are minimum for construction of the septic system. 6. Insulation required with 4' or less cover. 7. System to be installed by MOA certified installer. 6. Two (2) inspections are required by a Registered Civil Engineer. 9. No driveways on / over septic system. 10. 0.92 acre site undeveloped. �.�\\• ;49Nv*l �MURFlTT: 4977 ; �• 1/f/J74 o_ r."•cS�� It lk-W �. PLATE L H Construction, Inc. Septic Lot 11, Eaton Park Subdivision Chugiak, AK r Lot 5 r Lot 4 ''---4— — — — — � ----- r REBECCA HILL CIRCLE Lot 3 / y�i ��•' g4.72 N 89.42.05 E 120.p0 86.30 _ �r . \0'• 32.0' 3.0 X2.0' CANT 4.0' CoYcam PORCH HOUSE DETAIL SCALE: 1' - 30' MOUNTAIN NOTE: SEE ENGINEERS PLANS FOR LOCATION OF WELL AND SEPTIC. _6wr 1j. 1`•s'a F4v*4-b tac ) SUBDIVISION EXISTING ELEVATION PROPOSED ELEVATION SURFACE DRAINAGE LOT COVERAGE - 5.0% PLOT PLAN X AS BUILT _ SCALE _IL- 5T GRID NW 1361 Project No. 05-096 Lang & Associates, inc. 11500 Daryl Avenue, Anchorage. Alaska 99515-3049 (907) 522-6476 Phone Registered Land Surveyors (907) 522-4625 fax A k9langlsOaloska.net / jclangho aloska.net '`�•••• qs ersby certify that 1 have surmfed the following described property �Qr' Lot 11. EATON PARK SUBDIVISION �: 49g► chomge Recording Dlshrlaf, Alaska. and that the Improvements allua d thereon are .......... J .......... *" the property Bees and do not amoaah onto the property odIceent Mereto. that Improvenen% on the properly tying ooment thereto encroach on the swwyed urnhees and that then an no roadways, fmrmntaton Bms or other visible �, •• KENNETH .. r semenls on sold property except as Indicated hereon. LS -5202 led this the 'L')* Day of _(aP� w 2005 at Anchorage, Alaska� � • ..............m b the rasporolaBHy or the owner to deform*» the existence of any easements, �LA� �n� N .I..r.i..rrM� ..r.r..r. .1. —� r Y• J�J �.i Al • •J 2 I \ I I II \ wz° i I i Irl N, N jR�' SCl SOCil CO I I N \\ I N ` D I O W i m JI 1 W ° C I czi W MUHMPAU77Or- L, HCHORA�a 4�.e Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 051-111-79-000 Expiration Date: Legal description EATON PARK LT 11 Site address 24334 REBECCA HILL CIR Chugiak AK 99567 Current property owner(s) LATOCHA DEMITRIUS H & AMBER L 10/21/2023 X The On-site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: Original Certificate Date: 7/21/2023 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory x Tank Age Advisory Arsenic Advisory Other COSA Approval_June 2022 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 05111179000 Complete legal description Eaton Park L1 1 Location (site address) 24334 Rebecca Hill Cir. Current property owner(s) Demitrius & Amber Latocha 2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS Day phone 907-232-7797 3. TYPE OF WATER SUPPLY: X Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ❑E Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑E Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age 18 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ■❑ Bed ❑ Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: 89 Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ Waiver Fee $ Date of Payment COSA # V G 2 2 Date of Payment Waiver # COSA Application—June 2022 • Legal Description: Eaton Park L11 Parcel ID: 05111179000 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system 1 A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 1965 Total depth 246 ft Cased to 246 ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) 33 in. Well production at time of test 6.3 gpm Water storage tank volume n/a gallons Well disinfected for coliform test? E]Yes ❑ N ❑ Coliform bacteria is Negative Nitrate 5.25 mg/L E]Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Date of flow test for COSA 6/28/23 Collected by Brandon's On -Site Services LLC Static water level at beginning of test 164.5 ft Date 6/28/23 Comments There is no well log on file for this property, Information obtained from Municipal Records. B. TANK DATA Measured operating fluid level in septic tank 49.5" Date of pumping 9/26/22 ❑ Required maintenance completed, if AWWTS Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) 12/12/05 ❑ ALL standpipes present per record drawing Total measured depth from grade 13.8 ft (max) Measured depth to pipe invert from grade 12.9 ft (min) ❑ N/A — pressurized field. ❑ Per record drawings, field is insulated. ❑ Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) no If yes, enter date Comments/Deficiencies: COSA Checklist June 2022 C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: Adequacy test date 6/28/23 Results ❑ Pass Fluid depth prior to test 0 in Water added 605.3 gal New fluid depth 0 in Elapsed time 96 min Final fluid depth 0 in Absorption rate 605.3 gpd FIELD STATUS — POST RECOVERY Effective depth (per record drawings) 10.8 in Effective depth used 0 in Effective depth remaining 10.8 in E. SEPARATION DISTANCES From Private Well on Lot to:,(Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100' n Yes if No Community Sewer Manhole/Cleanout > 100' 0 Yes if No ft E Yes if No Neighboring Tank > 100' Fm] Yes if No ft Private Sewer/Septic Line > 25' ❑Yes if No Absorption Field on Lot > 100' 0 Yes if No ft Holding Tank > 100' Fm -1 Yes if No Neighboring Absorption Fields > 100' if No ft Animal Containment > 50' FE] Yes if No Fal Yes if No ft ft If tank or field is under driveway comment below Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' DYes if No ft Mm Yes if No ❑ N/A — Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10' n Yes if No ft Surface Water > 100' FEI Yes if No Tank to Property Line > 5' FE] Yes if No ft Wells on Adjacent Lots: Field to Property Line > 10' Q Yes if No ft Private Wells > 100' (Q Yes if No Water Main > 10' 0 Yes if No ft Community Wells > 200' no Yes if No _ Water Service Line > 10' Ful Yes if No ft If tank or field is under driveway comment below F. ENGINEER'S COMMENTS ft ft ft ft ft ft ft ft G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Walden Construction & Cons.& Eng., LLC. Engineer's Printed Name Robert Walden OFAC Y _ 9 Tl � y V , = ROBERT L. 'Vh%LDE_N 4 ���� '•• Na CE13874� ,.7/6/23...�G �V%, pROFEss�o�'? : COSA Checklist June 2022 Phone 907-354-6661 Date 7/6/2023 Invoice Date 7/19/2023 Invoice # 2022-249 Bill To Demetrius Latocha 24334 Rebecca Hill Cir. Chugiak, AK 99567 JR's Septic Pumping and Excavation PO Box 773415 Eagle River, AK 99577-3415 Project 24334 Rebecca Hill Cir. Terms Net 30 Thank you for your business. Phone # 9076946454 E-mail jrsseptic@gmail.com Web Site www.jrspumping.com Total Balance Due Payments/Credits Cash, Check, and Credit Card are all accepted payment methods. DescriptionQuantity Rate Amount Crew/equipment for 4-8 hours to repair belly in pipe after tank.4 275.00 1,100.00 Pipe/Fittings to repair bellied line. 30' of pipe @ $5/ft30 5.00 150.00 $1,250.00 $1,250.00 $0.00 Nitrate Advisory Certificate of On -Site Systems Approval # OSC231257 Subdivision: Eaton Park, Block: , Lot: 11 A water sample revealed a nitrate concentration of 5.25 milligrams per liter (mg/Q. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Since nitrates are known to slowly increase, we recommend you monitor the water quality. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. Madirig Address P O Bax 196650 *Anchorage, Alaska 99519 6650 *www muni org From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples. Mailing Address P O Box 196650 *Anchorage, Alaska 99519 6650 *www muni org 2.0' CANT 3' 33.1' 15.2'^' U 2 STORY w RESIDENCE HOUSE DETAIL Xr � 16.3' Scale: 1"=30' �— ry 1.0' CANT / \ 2.0' CANT °' DECK / \ 0 , CONCRET ' PATIO ,d.' W d 2" N 89'42'04"E 86.30' ASPHALT N DRIVEWAY O� WELL \ G"E 1°/ a N-LINKJL ' — ' GAS EASEMENT � ki t36 + FENCE SEE HOUSE DETAILFcn / r Lot 1 1 40,073 S.F. 1' `10.4'x4.0' o LOf 10 WOOD SHED Rt WOODEN FENCE \` " to l• \ <-SEPTIC �- / PIPES P E J WOODEN FENCE O � � \_ �f 15.2'x8.2' SHED \ 15' T&E WOODEN FENCE (EASEMENT �- rr \ S 89'54'58"W 179.35' Tract 3 MORTGAGE SURVEY X_ SCALE 1_ 50'— GRID NW 1361 Project No 23-308—/R1 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates, i n C. (907) 522-6476 Phone ken®langsurvey.com ®P Professional Land Surveyors jonathan0langsurvey.com OF ACgkk trovis*langsurvey.com ,mr P� , • ' ' ' ' ' . , s �� I hereby certify that I have surveyed the following described property: LOT 11, EATON PARK SUBDIVISION (PLAT No. 2005-52) Anchorage Recording District, Alaska, and that this Mortgage Location Survey is a representation of the conditions that were found on the date the survey was performed. This survey does not constitute a boundary survey and is subject to any inaccuracies that a subsequent boundary survey may disclose. The information contained hereon shall not be used to establish any fence, structure, or other improvements. t t L� 2 ;�? Dated this th®_ Day of , at Anchorage, Alaska It is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. co •' '!i,�$I *. 49TH . ... KENNETH G. LANG No. 1202 1�c�` • O State of Alaska AECC963 Municipality of Anchorage •• Development Services Department Building Safety Division r On -Site Water and Wastewater Program , A r 4700 Bragaw Street P.O. Box 196650 / (\ Anchorage, AK 895795650 � www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. COSA # 6b S8 Expiration Date: 1 1. GENERAL INFORMATION Complete legal description FiITOA/ C.-il on! Day phone Mailing address I 'DIS , e a✓ , Aje__ Location (site address) a.-133 rcef3E[cs} tl I�-L Lte Gitt.+Grr.tlL,A-IG Current Property owners) L • F E . UA15 TiKN C.-il on! Day phone Mailing address I 'DIS , e a✓ , Aje__ clRS-i -1 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA wN be held by DSD for pickup. `1 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Ell" Individual On-site ❑ Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of Onsite Systems Approval (COSA) based only upon the representations given in paragraph 4 by an Independent professional civil engineer registered in the State of Alaska. Certificates of Onsite Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also Issues COSAs upon request to homeowners. Certificates of Onsite Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions In the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my Investigation, based on procedures outlined In the Certificate of Onsite Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. I further verify that based on the Information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm _F_ tT-f-Z;- e- I JE-*-- r=" Ennte�trc 1M G,• Phone 6174-S1115 Address /m4 ,n_f ✓FW r d. -'0-of e7r , A -K- I95-17 Engineer's Printed Name GFtr-1 S -To e9 -17c_ Wnti» Date W16LOZ,.,- CHRISTOPHER R 5. DSD SIGNATURE a '. CE -10387 n.% Approved for q bedrooms. � ''�• Disapproved. "== Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory X Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report . Other By. ftn—Original Certificate Date: 107 (Rev. 11105) 1 Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-650 www.muni.org/onsite (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: Lot 11, Eaton Pads Subdivision Parcel ID: OS /"1 / 1-7 9 A. WELL DATA Well type "'"r' Date completed 1965 Total depth 246 ft. Date of best Static water level Web production N A, B, or C provide PWSID # _ Sanitary seal (Y/N) Yes Cased to 246 ft. FROM WELL LOG HMeteyynuw.�tvw.n>v� ��` Unknown ft. 10 9 -P.M. WATER SAMPLE RESULTS: Cotlform o colonies/l00 ml. Arsenic: 0 mg.A. B. SEPTICIHOLDINO TANK DATA Tank Type/Material Steil Nitrate 1.99 mg.A. Date of sample: ' Tank size 1250 gal. Number of Compartments 2 Foundation cleanout (YAC Yes Depression over tank (YIN) No Date of pumping C. ABSORPTION FIELD DATA Data installed 12/12/05 Length 60 ft. Total depth 14_0 ft. Pumper Soil rating (g.p.d.W or fethdrm) 0_7 Well Log (YM) U* Wires properly Protected (Y/N) Yes Casing height (above ground) 26.5 in. AT INSPECTION yyS g.p.m. Other bacteria 13 colonkWI00 ml. Collected by: Russell Hepner, Engineer Date installed 12MM Cleanouts (Y/N) Yes High water alarm (Y/N) No system" Bed Width 15 A. Gravel below pipe 0.9 ft. Eft. absorption area 900 ft Monitoring tube Yes Depression over field No Data of adequacy test Results (Pass/Fail) Fluid depth in absorption field before test _ in. Water added_ gal. For _ bedrooms New depth_ in. Elapsed Two: _ min. Final fluid depth _ in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N 8 type) If yes, give date D. LIFT STATION Date installed N/A 'Pump on' level at _ in. Datum Size in gallons 'Pump otr level at _ in. Cycles tested Manhole/Access (Y/N) _ High water alarm level at Meets alarm & circuit requiremer11s9 in. E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic;tankfidt station on lot 100' On adjacent kits 165' Absorption field on lot 113' On adjacent lots 103' Public sewer main N/A Public sewer manhole/cleanout N/A Sewer /septic service line 4' Holding tank WA SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 57' Property line eo_ Absorption field 20' Water main N/A Water service line 95' Surface water +150' Wells on adjacent lots 131' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 35' Building foundation 73' Water main NIA Water Service line 110' Surface water +150' Driveway. pancingNehide storage 120' Curtain drain N/A Wells on adjacent kits 15T F. COMMENTS 7 • -// Area not landscaped at this time. , F,: •• . G. ENGINEER'S CERTIFICATION I certify that 1 have determined through held inspections and review of Munbc4W records that the above systems are in conformance with MOA HAA gumWines in effect on this date. `d- �� A:iS:n _1_"i:,•.:iU, i i Engineer's Printed Name Allan W. Murfitt 9/13106 Date c s 1 HAA Fee $ Date of Payment Receipt Number xG (Rev. 1201) Waiver Fee $ Date of Payment Receipt Number, \ Municipality of Anchorage Development Services Department *A4 Building Safety DivisionOn-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. HAA # 5 Expiration Date: L Z 1. GENERAL INFORMATION Complete legal description Lot 11, Eaton Park Subdivision Location (site address or directions) 24334 Rebecca Hill Circle; Chugiak, AK 99567 Current Property owner(s) LH Construction, Inc. Day phone (907) 522-1616 Mailing address Lending agency Mailing address Real Estate Agent Mailing Address 12130 Regency Drive; Eagle River, AK 99577 Dena Llthgow, Northern Trust Real Estate 205 E. Benson Blvd.; Anchorage, AK 99503 Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: Individual Well ❑ Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ Day phone Day phone (907) 441-1339 TYPE OF WASTEWATER DISPOSAL: Individual On-site El Individual Holding tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions In the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm A.W. Murrill, Company Phone (907) 345-2737 Address 13810 Venus Way; Anchorage, AK 99515 Engineer's Printed Name Allan W. Murfitt Date 9113106 AIIanW 6. DSD SIGNATURE Approved for 3 bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: HAA Checklist X Maintenance Agreements Septic System Advisory Supplemental Engineer's Report Well Flow Advisory Other By: Original Certificate Date: tf It z1 s (Ra. 01M WMI SGS ReCN 1065815001 Client Name A.W. Murfitt Co. Inc. Project Name/N Lot I I Eaton Park Sub Client Sample ID Lot 1I Eaton Park Sub Ilfatria Drinking Water PWSID 0 Sample Remarks: All Dstes/rimes are Alaska Standard Time Printed Date/Time 10/052006 15:32 Collected Datdrime 09272006 10:35 Received Date/time 09272006 11:25 Technical Director Stephen C. Ede Allowable Prep Analysis Parameter Results PQL Units Mdhod Container ID Limits Date Dam Init Waters Departtaent Nitrate -N 122 Microbiology Laboratory Total Colirorm 0 0.100 mg/L EPA 353.2 B (<10) 0927/06 ALR coV100mL SM2092220 - A (<q 0927/06 DPT SCS Rct.M 1061294001 Client Name A.W. Murrill Co. Inc. Project Name/N Lot 11 Eaton Park Subd Client Sample ID Lot I 1 Eaton Park Subd Alstria Drinking Watcr PWSID 0 All DatesMones are Alaska Standard Time Printed Datelrime 03/31/2006 13:33 Collected Datdrime 03/16/2006 11:40 Rteeived Datdrimc 03/16/2006 17:07 Technical Director Stephen C. Ede Sample Remarks: Allowable Prep Analysis Parameter Results POL Units Medad Container ID Limits Date Date ]nit Waters Department Nitrate -N 1.99 0.100 mg/L EPA 333.2 D (<=I0) 03/17/06 AZS Microbiology Laboratory Total Coliform 13 O6, No Coli col/100mL SM209222D A 1) 03/16/06 DPT SCS ReLN 1061353003 Client Name A.W. Murfat Co. Inc. Project Name/M Eaton Rock Subd Client Sample ID Lot I 1 Eaton Park Matrix Drinking Water PN'SID 0 Sample Remarks: All Dates/Times arc Alaska Standard Time Printed DatdPime 04/10/2006 15:19 Collected Datelfime 03/21/2006 14:35 Received Date/Time 03121/2006 15:48 Technical Director Stephen C. Ede Allowable Prep Analysis Parameter Results PQL Units Method Container ID Limits Date Date Init Metals by ZCP/MS Arsenic ND 5.00 ug/L EP200.8 A («10) 03128/06 04/05/06 SCL A.W. Murfitt Company_ CONSULTING ENGINEERS & TESTING 13810 Venus Way • Anchorage, Alaska 99515 • Telephone (907) 345-2737 • FAX (907) 345.3264 November 17, 2006 Municipality of Anchorage Department of Health & Human Services On -Site Services P.O. Box 196650 Anchorage, AK 99519-6650 ATTENTION: Mr. Jeff Poet Civil Engineer RE: Lot 11, Eaton Park Subdivision Septic System NEI/4, T15N, RIW, Sec. 10, S.M., AK Chugiak, Alaska AWM Co. Job 06-394.14 Dear Mr. Poet: This letter has been prepared in response to your concern about the separation distance between the well and the 1,250 gallon steel septic tank that has been installed at the above referenced property. The separation distance in question was found to be a minimum of 100 -ft. both when measured on site when the tank was being installed and again when the as -built survey was done. I am satisfied that the separation distance between the well and tank meet Municipality of Anchorage Setback Requirements for an on-site well and septic system. Please do not hesitate to call if you have any questions, or we can be of additional assistance in this matter Sincerely, A.W. Murfitt Company Russell Ilepncr, E.I.T. Civil Engineer 10-10 t✓xtL[ nivrn G'arLvrLrtin" lrmIV.7U' r oy4 a[yf r. me/W.:i Eagle River Engineering Services C61A p6er IL Wows, P.E 10421 VFW RJ. Sint. 201 (907) 6945195 t.l Eagle Rtvrr, AK 99577 (907) 6943297 fax RESIDENTIAL WELL FLOW TEST LEGAL: Eaton Park Subdivision lot 11 LOCATION: Rebecca Hill drive OWNER/CLIENT: LH Construction TYPE OF WELL: Private WELL LOG AVAILABLE: Yes PUMP RATE: 4.8 GPM (pump only) WELL PRODUCTION RATE: +4.8GPM DATE OF TEST: 11/162006 TEST PROCEDURF. The well was pumped at an average rote of 4.8 GPM. Total water level drawdown from a static water level of 173 feel was 17 feet after 30 minutes of pumping. After the initial drawdown, the water level in the casing stabilized for the remaining time it was pumped. With the use of a sonar and calculation of total water amount for drawdown cycle, flow rate of the well was monitored and calculated at an average rate of +4.8 GPM for the first stage of recovery. This flow rate Is a maximum rate that can be established by use of the installed pump. TEST RESULTS The well flow rate meets the basic requirements of Municipality of Anchorage for a 3 bedroom single family residence as of the day the system was tested. It also meets the FHA 3 GPM for 4 hours requirement for water supply. The assessment of the condition of this well applies only to the conditions as of this date. The flow rete of any well may change due to subsurface conditions that may not be observed from the surface, changes in land use and other factors that may impact the conditions of the aquifer supplying the well. There is no guarantee that the well system tested will meet the requirement for approval in the future. The test data and investigation of existing conditions is provided to our client for submittal to the Municipal t1997W6419S EATON WELL AOI'Q.Ooc Pace 101`2 tvuv-t t-evxuvnl) to. to CMt7LC nlvrn Cr,UIIW r%lr&3 trnn)avlr oxl acot r. "W/M* Olt -Site for their review and approval. Any eoncems with this test report should be discussed with the testing engineer. If it is requested, we will submit the report directly to the Municipality. 9997\06-M EVON wr>u. AncQ.dm Past 2 of2- Municipality of Anchorage Development Services Department • +.� Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: Allen Murfit Legal description: Eaton Park Lot 11 The attached paperwork has been reviewed and Is being returned for the following reasons: ❑ Original signature or stamp missing on ❑ Calculation error In design. _ ❑ Additional soils information needed. _ ❑ Water monitoring results inadequate. ® Discrepancy in information submitted. Tank less than 100 feet from well. ❑ Topographic information missing or inadequate. _ ® Incomplete; missing Well flow test. ❑ Incomplete; missing _ ❑ Additional adequacy test information needed. ❑ Water sample unacceptable. _ ❑ Measured/proposed distances/dimensions missing. _ ❑ Locations of all soils, percolation and water monitoring tests not shown. ❑ Proposed system too deep for soils Information submitted. ❑ Well log required. ❑ Omission in narrative. _ ❑ Insufficient fill over tank or field. ® Other. Water samples out -dated, not valid. 6 1%e_ Name of reviewer: Jeff �'✓ Date: 9 21-06 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK