Loading...
HomeMy WebLinkAboutUS SURVEY 3042 LT 83 T10N R2E SEC 19US Survey 3042 Lot 83 #075-132- 20 ¢  Municipality of Anchorage .~-'~ ~".., Development Services Department .~ ~ ~ o Building Safety Division : ~..,,~ "= ~ On-Site Water & Wastewater Program. 4700 Bragaw St. ~.~'~ P.O. Box 196650 Anchorage, AK 99519-6650 ~ ~' wwv.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number:. SW080254 PID Number:. 075-- 132--20 Name: GUY WADE Wastewater System: [:] New · Upgrade Address: PO BOX 248 GIRDWOOD. AK 99587 ABSORPTION FIELD Phone: NO, of Bedrooms: (907) 785-4300 3 I'lDeep Trench I'1Shellow Trench · Sed I'lMound ~30~her LEGAL DESCRIPTION 2.0 ~,o/s,. eLI I TO TOP OF SAND - 85 US SURVERY 3042 0.27 ,LI 0.73 Township: 10N Range: 2E ~ection: 19 m ee~d ~ ~ ~: ~ SEE DWG. ~t 25 rL WELL: E] New [:] Upgrade 10 ~ 2I 5 PRIVATE 325 n. 258 ~L 250 SO. rL ) 3034/ F-810/SCH 40 HEF'P( DRILLING 11/17/08 27 rt OWNER 12-14/2009 3.5 c~I 289 '~I 24+ ,, TANK SEPARATION DISTANCES a s,pt~c o Holding I't S.T.£.P.=Other* Tank Field Station Tank s.., u.. GREER 1500 wel~ 100'+ 100'+ 100'+ - 25% STEEL 2 su,o¢o water lOO', lOO', lOO', - - LIFT STATION Lot Line 5'+ 10'+ 5'+ - - 1500I QUAINICS/GREER - TIMER TIMER 44" Curtain Drain NONEi KNOWNi P-T£-30-PLUS DIMOND ELECTRIC COMPANY INC. ~ernerks: *THIS IS A QUANICS AEROCELL UNIT BENCH MARK NOTE: CONDITIONAL APPROVAL CONTINGENT ON: TOP OF ME-I'AL FLASHING OVER CMU FOUNDATION 1. ORIGINAL WELL TO BE DISCONNECTED FROU CABIN. 2. OUTHOUSE TO BE ABANDONED PER CODE. NEAR FRONT DOOR OF THE HOUSE 3. MOUND TO BE ~ SEEDED. ~ [~,.,,t,~= 100.00 Inspections performed by: GE(;, Ltd. Dates: 2ndlSt 8/12/20098/12/2009 ~-~'d~. 0'-. z~.~' ~.~'~J .~.~c~ 3rd 8/14/2009 Development Services Department Approval ~.,.v).:.:-.! ! ~.~....:.: .-~..i1 R~viewed and approved by: Dote: %~,~,,~.o f .,,~o%0~=:.~~ PERM[T NUMB/R: AS BUIL? :DRAWING PARC[LID NUMBER: SW080254 - 075-152-20 C01 88.111 91.54 // JV 120.76 126.18// / ~ .TI ,,~.~ ,~.~, / 1,~.~ ~ ~ ~ _-~ CO5 143.56 150.79 ~./ ~ I~1 / ~ APPROVAL. ORIGINAL WELL ~I / / ~ ~ MUST BE DISCONNECTED - /~ / ~ ..o. ~.,,. o~.o~ // / ~ / ~ ~ol MU~ BE FILLED AND ~ / ~' ~.~o,~ .~ coo~. ~/ L - / ~ ~ _ D~INFIELD MU~ BE ~ / ~7--._., / ~ o~o~,o ~ / GARNESS ENGINEERING GROUP,, Ltd ,i~')54'~' GUY WADE 785-4500 2 OF 5 ~*~ '..J,~f ~fA. Cornjss.: AS-BUILT DRAWING 12/2/2009 A B C01 88.11 91.54 JV 120.76 126.18 C02 120.18 126.46 C03 116.78 128.47 C04 122.97 1,34.,.35 MT2 124.21 135.09 C05 14,:3.56 150.79 MH 154.111 162.78 Municipality of Anchorage P.O. Box 196650 · 4700 Elrnore Road Anchorage, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997 htt p://www, m unLorf:l/Onslte Development Services Department On-Site Water and Wastewater Program ~epar tmet~t ON-SITE SEWEPJVVELL SUBMITTAL COMMENT SHEET To: Jeff Gamess Legal description: r-]Permit C.O.S.A. US Survey 3042 Lot 83 I~lnspectlon Report The attached paperwork has been reviewed and is being returned for the following reasons: 1. Well at cabin to be modified to an agriculture well and water samples collected by the engineer and reported to On-Site. 2. Outhouse to be abandoned per code. 3. Mound to be vegetated by 6-15-10. Name of reviewer: Jeff Date: 1-7-10 Please supply the necessary information and re-submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK Please accept this correspondence as confirmation that Dimond Electric Company inc. has completed all electrical installation to date at the new Wade residence. This work includes power and control cable installation for the sewer system for the residence. Give me a call if you have any questions. Sincerely, Paul Lantz General Manager Dimond Electric Company, Inc. 8101 Dimond Hook Dr. Anchorage, AK 99507 AK business lic. #169231, contractor lic. #18388 SG$ Refo# Client Name Project Nlme/# Client Sample 1096535001 Garness Engineering Group, Ltd USS 3042 Lot 83 USS 3042 Lot 83 Drinking: Water Printed Date/Time Collected Date/Time Received Date/Time Technical Director 12/22/2009 9:45 12/10/2009 9:20 12/10/2009 11:50 Stephen C, Ede Sample Remarks: Allowable Prep Analysis Parameter ResulL~ PQL Units Method Con'net ID Limits Date Date Init ~e~als b~, zcx,/v~s Arsenic 14.4 * ~.00 ug/L EP200.8 C (<10) 12/17/09 12/21/09 NRB Wa e. ers Department Total Nitrate/Ni~te-N ND 0.100 mg/L SM204500NO3-F B (<10) 12/11/09 RJT 14.t crobioloeffy 7.~bora t:o:y Colony Count 0 Total Coliform 0 Fecal Coliform 0 col/100mL SM20 9222B A (<200) col/100mL SM20 9222B A (<1) col/100mL SM20 9222B A (<1) 12/10/09 DLC 12/10/09 DLC 12/10/09 DLC  Municipality of Anchorage Development Services Department Building Safety Division ..':'~ =-' On-Site Water & Wastewater Program. 4700 Bragaw St. :~ P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak, us (907) 343-7904 Page 1 of On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW080254 PID Number: 075-1 52-20 Name: GUY WADE Wastewater System: [] New · Upgrade Address: PO BOX 248 GIRDWOOD, AK 99587 ABSORPTION FIELD 'Phone: No. of Bedrooms: (907) 783-4300 3 I-I Deep Trench [] Shallow Trench · Bed FIMound I-IOther LEGAL DESCRIPTION ,sol, Rating: Total Depth from original grade: 2.0 GPD/S,. rt. 1 TO TOP OF SAND Et. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: - 83 _ US SURVERY 5042 0.27 Ft. 0.75 Ft. Township: 1 ON Range: 2E Section: 1 9 Fill added above original grade: Grovel length: SEE DWG. Ft 25 Ft. Gravel width: !Number of lines: Distance between lines: WELL:[] New [] Upgrade 1 0 rt. 2 5 rt Cl~;f;cation (Private, A.B,C): Total Depth: Cased To:(BEDROCK) Total absorption area: Pipe material: PRIVATE ,525 Ft. 258 Ft. 250 SQ. Ft.D ,5034/ F-810/SCH 40 Driller: Date Drilled: Static Water Level: Installer: HEFTY DRILLING 11/17/08 27 Ft. OWNER Date installed/12--14/2009 Yield: [Pump Set At: Casing H,:;9;-,t Above Ground: ,5.5 GPMJ 289 rt. 24+ ,,. TANK SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. · Other* T~ To Septic Absorption Lift Holding Public/Private Manufacturen Capacity in gallons: From ~ Tank Field Station Tank Sewer Lines GREER 1500 Material: Number of compartments: Well 100'+ 100'+ 100'+ - 25% STEEL 2 Sa,ace Water 100'+ 100'+ 100'+ - - LIFT STATION Lot Line 5'+ 1 O'-f- 5'-I- -- -- Size in gallons: I Manufacturer:. 1500J QUAINICS/GREER Foundation 5'+ 1 O'-l- 5'--I- _ _ 'Pump on' level at: "Pump off' level at: [High water alarm at: TIMER TIMERI 44" Curtain Drain - NONE KNOWN . Pump Make & Model: Electrical Inspections performed by: I I P-TE-50-PLUS DIMOND ELECTRIC COMPANY INC. Remarks: *THIS IS A QUANICS AEROCELL UNIT BENCH MARK Location and Description: NOTE: CONDITIONAL APPROVAL CONTINGENT ON: TOP OF METAL FLASHING OVER CMU FOUNDATION 1. ORIGINAL WELL TO BE DISCONNECTED FROM CABIN. 2. OUTHOUSE TO BE ABANDONED PER CODE. NEAR FRONT DOOR OF THE HOUSE 5, MOUND TO BE -TC,~C.;',~D,. . . .*,;~ SEEDED. Assumed Elevation: 100.00 Ft. ENGINEER'S SEAL Inspections performed by: OEO, Ltd. Dates: 1st 8/12/2009 ~'~'~ 2nd 8/12/2009 ~ 3rd 8/14/2009 ~: :~'"'f~.~....~[~!~. Development Services Depa~ment Approval '~'~.-' ¥ .,~_TFt"~I ¢ ".?~ Conditionalapproval: Q,~_//,,-~/~'~'//~,~ /~~ Dote:/' 7-,0 (~/'"'"""? ~~~'"'"' .... ' ~Z .'3 ~ ~ .... Reviewed and approved by'~CU? ¢- ,' ¢~,~( /, Dote: / '~%( (Rev. 4/OS) ,./¢/ ~ . PERMIT NUMBER: AS BU'~T DP~~G PARCELID NUMBER: SW080254 - 075-152-20 A B C01 88.11 91.54 JV 120.76 126.18 C02 120.18 126.46 MT1 116.75 125.61 C05 116.78 128.47 C04 122.97 154.55 MT2 124.21 155.09 C05 145.56 150.79 ST1 146.17 155.71 MH 154.11 162.78 650 AEROCELL + THi~2 NEW 1500 GALLON S.T.E.P. TANK / / / ALTERNATE SITE / NEW BEDROOM HOUSE I 1" = 4.0' GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS 3701 E. TUDOR RO~, SUITE 101 ' ,MICI~. AK 9~507 ' ~ (~07)337-6179 ' FAg (907)3,~8-3246 · W~: PREPARED FOR: I PHONE NUMBER: i PAGE NUMBER: GUY WADE I 785-4500 I 2 OF 5 LEGAL DESCRIPTION: I DRAWN ~ US SURVEY 5042, LOT 85 (TI ON, R2E, SECTION 9) M TYPE Or WORK: IDATE: REVISED AS-BUILT DRAWING I 11/21/2011 / / (Rev. 01~05) / .,/ /~ \ \ \ \ \ o ~>m~ o~-< ~mm m v.--I rtl DATE: 10/8/2009 LEGAL DESCRIPTION: US SURVEY ..3042, LOT LYPE OF WORK: AS-BUiLT OF ~T'~E:D FOR: ~ GUY WADE IDRAWN BY: K.D.M. 85 ( TION, R2E, SEC 9) QUANICS AEROCELL SYSTEM JPHONE NUMBER: 78.3-4.300 0 7 '--I :~> Z -4 "0 0 0 II ~ GA'RNESS ENGINEERING GROUP, Ltd. ~'~'~:~,:~'~11~ CONSULTAN"I'~ & GENERAL C~ ~'~> mm Z;:O '-'lO Cm Z~ I CE-~7953 We# Log ~ ~ 2: 45~ Box 248 Girdwood. AK ~7 silt & gravel wet silt & gravel silty' gravel w/little H20 dry silt & gravel ~c bedrock w/H20 258 !259 '2170 bedrock(shale)will layers 259 bedrock wi H20 fractures 270 280 Wa~ enterin~g we!!..o.p,t0p,,of bedrock and thru r ewn~ shal~ provide a well log to the l DSD .w~in 60 ~ of well compl~on, i'~ ~¢.,,. >~=~,~ SW080245 ~PR-~1~009 O~:~P ~RO~: T0:~7997 lox WA~R TAN~ well was disinfected upon completion., method: calcium hypochlorite. .3.25, Water Weg anaF ~Pun~ Service 9~ncfwra~e, fl(a.s~a SGS Ref.# Client Name Project Name/# Client Sample ID Matrix 1115534001 Gamess Engineering U.S. Survey 3042 L83~ U.S. Survey 3042 L83 AG~WELL Drinking Water Printed Date/Time Collected Date/Time Received Date/Time Technical Director 11/15/2011 8:55 11/09/2011 13:30 11/09/2011 14:50 Stel~hen C. Ede PWSID 0 Sample Remarks: Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Metals by ICP/MS Arsenic ND 5.00 ug/L EP200.8 C (<I0) 11/09/11 11/11/11 NRB Waters Department TotalNitrate/Nitrite-N ND 0.100 mg/L SM20 4500NO3-F B (<10) 11/10/11 AYC Microbiology Laboratory Colony Count 0 col/100mL SM20 9222B A (<200) 11/09/11 DLC Fecal Coliform 0 col/100mL SM20 9222B A (<1) 11/09/ll DLC Total Coliform 0 col/100mL SM20 9222B A (<1) 11/09/11 DLC LOT 82 EXISTING HOUSE WELL LOT 8.3 BLM PATENT BK. 242 PG. 347 LOT 84A LIFT (~D ~ SEPTIC STATION ~ STANDPIPES ELECTRIC(~ (~ (~) LIFT STATION OUT HOUSE EXISTING LOT 84D BUILDINGS PEDESTAL NOTE: THIS DRAWING IS NOT TO BE MODIFIED FOR USE AS A PLOT PLAN WITHOUT THE EXPRESSED WRITTEN CONSENT OF. LANTECH. 5/8"RB W/CAP ~) Uff Sro[ion (D ~Overhang~ U.S. Survey No. 504-2, ~/~' .® (~ sept,~ sta.dp,p. ~ , Girdwood Small TractGroup I 5/8' RB O J ~ J ~ ~j p~perty os shown on this dr~w~g ~nd c~lfles that the Improvements ~ ~ ~ ~ ~ ~ ~ - ~J ¢~et~ ~n are ~thin ~e prepay lin~ ond no ~oa~ments exit ~ m ~ ~X~ON~Y NO~ It la the o~' reap~b~ity to det~ine the LAND ~ CONS~UCTION SUR~YORS-PLANNERS-ENGINEERS~. . , , ' - - Azn w~.~ n~.~. o~.1 .... ~ ¢..~ o~n m~ . ~:~ ~ns[ takings whch do not appear on ~e rec~d~ ~bdi~si~ plat. Und~ ~orage, Alaska 99503 Fa~ 551-6626~ for e~fieht~ property lin~, ~ f~ plot-plan pu~ose& MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Renewal Date Issued: Dec 10, 2008 Expiration Date: Dec 10, 2009 Permit Number: SW080254 Legal Description: US SURVEY 3042 LT 83 T10N R2E SEC 19 Design Engineer: 0855 GARNESS ENGINEERING GROU[: Owner Name: GUY WADE Owner Address: PO BOX 248 GIRDWOOD, AK 99587- Parcel ID: 075-132-20 Site Address: Lot Size: 55539 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. Ail requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. -THE UPPER SIX INCHES OF THE MOUND SYSTEM MUST CONSIST OF TOP SOIL AND THE MOUND MUST BE VEGETATED SUFFICIENTLY TO PREVENT EROSION. Date: Date: ~.~///~/~ umc~pauty of A'fi'cfi3rage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. BOX 196650 Anchorage, Alaska 99507 www.muni.org/onsite (907) 343-7904 ON-SITE SEWERANELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING ParcelI.D. Prope. owner(s) / UU tl)0 lt. Site address. Legal description (Sub'd., Block & Lot) _. Day phone fii ode Legal description (Township, Range & Section) . Lot Size. ~.~, rO:2~ Sq. Ft. Zip Code , Number of Bedrooms THIS APPLICATION IS FOR ([~ all that apply): THIS APPLICATION IS AN: Absorption Field ~ Initial [] Septic Tank ~ Upgrade [] Holding Tank [] Renewal Privy [] ~ Private Well [] Water Storage [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. / (Signature of propj~ owne~or a~thorized agent) Permit/Rush Fees: . Date of Payment: Receipt Number. . (Rev. 11/05) Waiver Fees:. Date of Payment: Receipt Number:. MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WATER SUPPLY PERMIT Initial Date Issued: Nov 05, 2008 Expiration Date: Nov 05, 2009 Permit Number: SW080245 Legal Description: US SURVEY 3042 LT 83 T10N R2E SEC 19 Design Engineer: 0000 77. NONE NEEDED Owner Name: GUY WADE Owner Address: PO BOX 248 GIRDWOOD, AK 99587- Parcel ID: 075-132-20 Site Address: Lot Size: 55539 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. Ail requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: _ ~ ~'/ Issued By: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, Alaska 99507 www.muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 075-132-20 Property owner(s) Guy D Wade Mailing address po box 248, Girdwood, AK Site address 246 Jewel Mine Rd. Girdwood. AK Legal description (Sub'd., Block & Lot) ,us survey 3042 Lot 83 Legal description (Township, Range & Section) T10N R2E SEC 19 Lot Si:,e 55,539 Sq. Ft. Number of Bedrooms 3 Day phone 907-382-7774 Zip Code 99587 Zip Code 99587 THIS APPLICATION IS FOR (~;~ all that apply): Absorption Field Septic Tank Holding Tank Privy Pdvate Well [] Water Storage [] THIS APPLICATION IS AN: Initial Upgrade Renewal I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature ot~'property owner or authorized agent) Permit/Rush Fees: ] '7 .~"' Waiver Fees: Date of Payment: / O - ~ O - O,,~ Date of Payment: , Receipt Number:. /~ ~/ ~ ~' ,~- '~ ,/~c::Receipt Number. .. (Rev. 11~5) ~V ~44)~ lopl~ LOT 82 ? USE ZONE ,VED PROPOSF.D HOUSE FIN, FLR. = 112,5' LOT 83 BUd PATENT BK. 242 PG. 347 55,539 sq.ft.:l: J~nn¥ Rose 08E LOT 84A hall bo done as shown on this p 8n Approved glans and specilicatiom I not be changed, modified or aered Jg a valid change order. OUT HOUSE EXIS'BNG BUILDINGS (R) RECORD pER USS 3042 (M) MEASURED ~llS SURV[Y AS-BUILT / PLOT PLAN Lot. 83 U.S. Survey No. 3042, Girdwood Smell Tract Group LAND & CONSTRUCTION SURV[YORS-PLANNERS-F' 440 West Benson Boulevard, Suite 200 Phone: 562-5291 Anchorage, 99503 Fox: 561-6626 Plat Xo: USS 3042 C~d NO: SE5012 w~ o~. 2008LH123 715/55-54 LOT 84D ezv.(.o D^~U~)- ~ ~ PROPOS[0 ~NISH GRADE: DRAINACr O,d*,,~ Sr- Guy Wade Legend: Fnd out H~.e (~) S/$'RB W/CAP (~) $/~' RB 0 Wat~ w~ ~ 3/4' R~ ~ M~UM~T ~ Fmce ~X~X ~ubdlvls on p . . · os shown o~ this drawing and that the Improvements altuated ore within the property lines and no encroachments exist other ~oted. Dote: Aug 18, 2008 Ora~m er- NRB ~a~ 1"=40' ~ e~ JMZ MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (gO7) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Dec 17, 2007 Expiration Date: Dec 16, 2008 Permit Number: SW070323 Legal Description: US SURVEY 3042 LT 83 T10N R2E SEC 19 Design Engineer: 0855 GARNESS ENGINEERING GROUI~ Owner Name: GUY WADE Owner Address: PO BOX 248 GIRDWOOD, AK 99587- Parcel ID: 075-132-20 Site Address: Lot Size: 55539 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [] DisposalField [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day, B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. -THE UPPER SIX INCHES OF THE MOUND SYSTEM MUST CONSIST OF TOP SOIL AND THE MOUND MUST BE VEGETATED SUFFICIENTLY TO PREVENT EROSION. Received By:. Issued Date: Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw SL P.O. Box 196650 Anchorage, AK 99519-6650 www.cLanchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERHIT APPLICATION FOR A SINGLE FAHILY DWELLING Parcel I.D. Property owner(s) Mailing address Site address CUY Legal description (Sub'd, Block & Lot) uS. SURVEY 3047. tOT 83 Legal descripUon (Township, Section & Range) N/a Lot Size ~, ~:"~ Sq.Ft. Day phone Zip Code 783-4~00 99587 Number of Bedrooms THIS APPLICATION IS FOR ( r'~ all that apply): Absorption Field Septic Tank Holding Tank Privy Private Well . Water Storage THIS APPLICATION IS AN: [] Initial ~ Upgrade Renewal I certify that the above information is correct. I further certify that this application Is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. CARNE$S E'NCINEI~RINC CROUP, Ltd. -(Signature-of property-O~l~e~.'~l IthOrized agent)- Permit/Rush Fees: '~ "/('" O. (.~,-.~ Date of Payment: I ~--/C, /~'7 Receipt Number. '70 5 ~ (Rev. I i/05) Waiver Fees: Date of Payment: Receipt Number:. GARNESS ENGINEERING GROUP, Ltd, · , - .: .-~ :':'~" ~ CONSULTANTS & GENERAL CONTRACTORS r.: December 7, 2007 Municipality of Anchorage Dcvelopment Service Department On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Proposed Septic System for U.S. Survey 3042; Lot 83 To whom it may concern: The referenced property has an existing cabin built on it with an existing well. There is no septic system except for an outhouse. The owner of the propcrty is proposing to build a 3 bedroom house on the property which will bc served by the existing well and a proposed septic system. Two test holes were excavated. Due to shallow groundwater, we are proposing to use a Quanics Aercoell treatment system to minimize the drainfield size and the amount of fill to be imported. The septic system will consist of 1500 gallon septic tank, a 36" pump vault, a 650 gpd Aerocell unit with Jandy valve basin and a bcd type dminficld. The dminfield will be designed around the 30 foot radius of test hole gl. The existing cabin is to remain in place and be converted to a heated storage unit per the owner. A well reserve site is shown on thc site plan and design drawing. The owner may want to subdivide the property at a later date. This well is not to be drilled at this time and will require a well permit in the future. Comments regarding the design are summarized as follows: !. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. 4. TOI'OGRAPllY: The average topography in the area of the drainfield is a I-5 percent slope running approximately north/northwest to southeast. In short, there are no slope concerns. We are unaware of on.adverse impacts this installation would have on adjacent wells or septic systems. If you have any que~io~, ~lease contact us at 337-6179. Thank you for your assistance. X, 415. mess, V.E., U.. Presidlnt/ PlOT~: Attached is a site plan drawing, a design drawing, two detail drawings, and two soil logs, which are all part of the design package for this septic system. (Contact G.E. G. Ltd. for 7page construction specification letter.) 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com U.S. SUR~' .3042. LOT 82 \ ~ ~ B£DROOM \ ~o~ / .S, ~42. / /, ~2. ~42. LOT / / SEPTIC 3042, LOT ~, ~t U.S* SU~ ~42. ~-~ ~ ~ / ~o~. / u.~.~,~,~ 7~ / / GARNESS ENG //e : .~o.~.~o~.~o.~o.~ ~1~' ~t~/47 .......... ' .... GUY WADE go7-783-4~O0 u.s. SURVEY ~042. tOT e~ (T~O,. r2e. stetro, SITE P~N FOR PROPOSED SEPTIC SYSTEM NUUBDt OF BI:DROOUS: 3 / TO OBTA/N A COPY OF THE ~ER % ~ // // ~ SE?.~ T~R~ ~ ~ .:.,~. ~.~/ ~ ~ NOTE: THE EXISTING ~BIN ~[O 3S ~uP ~ / ~,,~:~?~ ~ ~ AND SHED ARE TO ~ /~ F~ ':'"~/~-~ ~o~. TO .~ ~ I / ~CONSULTAN~&GENE~LCON~C~S~I ' ........ '[ ?rT'~' · ~ .., ~. Cot ess.- , i 2/7/2007 ~ DESIGN Or PROPOSED SEPTIC , _/ I 0 · ¢' MONITORING TUBE 4' P~RFORAT[D PIPE 25 FEET W~DE PREPAJ~ED FOR: PHONE NUMBER: PACE NUIdBCR: GUY WADE I 907-785-430 If'GAL D~SCRIpTION: DI~AWN ~. M* Pr"l klflO~lO_ON~ll:l.~z--iNlON..;i ~o~'av SOINVnO .:lO:~Ol~?aOd,u '~'Tr I zooz/z/~l CONSU/'I'AN'r~ & OENERA~ CONTRACTORS ISOIL LOG - PERCO~TION TESTI [-~.j.~.j/..~ ..... J ........ feet): OR~ICS/ROOTS ITEST HOLE ~ GW ::: ORG GC OL SP CH --~ SM OH SC DEPTH TO DATE ~. 78" 11/12/07 ~ / ~ 10 11 DATE READING CLOCK NET TIHE WATER LEVEL~ NET DROP TIHE (HINUTES) READING (INCHES) t2 11/5/07 1 3:36 - 6- - 2 4:06 30 5" 1' 13 3 4:06 - 6" - 4 4:36 30 5' 1' 14 5 4:36 - 6' - 6 5:06 30 5' 1' 15 16 1 18~ PERCOLATION RATE 30 (HIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19~ ' TEST RUN BETWEEN. 1.5 FT. ~D 2.0 FT. 20 ~ A FOUR HOUR PRESOAK WAS PERFORHED: ~ YES D NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORHED BY: PIERCE BL~ COHHENTS: PERFORMED BY CEG, Ltd. I, JEFFR~ ~ ~RNESS, CER/I~ T~T THIS WAS pERFORMED IN ACCORD~CE WITH ~L STATE ~D MUNICIP~ CUIDEUNES IN EFFECT ON THIS DATE: GARNESS ENGINEERING GROUP, Ltd. ~'~ ~T~_~: '".'.W.'~N ' CONSULTANTS & (3ENEI~/CONTRACTORS ~'~ ~.'~.'~..g...~ ...... ~ .~. :~, ISOIL LOG - PERCO~TIOH ~E$TI ~.~:/ ~.~....~ .......... .~, LE~ DESCRIPTION' USS 3042 LOT 83 '~~ __ ~ ~.' ~.:~ · CE-~ .' ~EPTH ~ feet) OR~CS/.OOTS IIESI HOLE ~2~ ~ GW ~ ORG ~ , ,DUSE GM CL , GC OL sw .. / s~ CH / X/~"5~fL- .... --.,',  SH OH / SC P.oPos~o SEPTIC GROUNDWATER 10 11 DATE READING CLOCK NET TI~E WATER LEVEL NET DROP TIHE (HINUTES) READING (INCHES) PERCOLATION RATE - (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 TEST RUN BETWEEN - FT, AND FT, 2 A FOUR HOUR PRESOAK WAS PERFORMED: D YES D NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: COMMENTS: PERFORMED ~ CEG. Ltd. I, JEFFR~ A, ~NESS, CERTI~ T~T THIS W~PERFORMED IN ACCORD~CE WITH ~L STATE ~D MUNICIP~ GUIDELINES IN EFFECT ON THIS DATE: I ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT E WEEN WNICIPAUW ^NCnO E THIS MEMORANDUM OF UNDERSTANDING made and entered into as of this herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY." In consideration of the mutual covenants contained herein, the parties to'this Memorandum of Understanding agree as follows: 1. ADVANCED WASTEWATER TREATMENT SYSTEMS. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as /4erafe~ { located at 0.~ ~tqT- /~E~3 ~'/0/,-) ]~Z~' .~e~_ 1~ ,Anchorage, Alaska. 2. Definitions. A. Alteration. Any change to the design or function of an AWWTS that Includes the installation or removal of any parts, components or pieces not included in the original construction permit and design. Prior to performing any alterations to an AWWTS the owner must obtain a Wastewater Disposal System Construction Permit from the Municipality pursuant to Anchorage Municipal Code (hereinafter, "AMC") 15.65. B. Certificate of On-Site Systems Approval An approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with AMC 15.65. These approvals certify that the systems are adequate for the homes that they support and meet the codes that were in place at the time of system construction. C. Damage. Any man-made or natural change in a system that would inhibit the system from performing as designed. D. Maintenance and Repair. The scheduled and as needed replacement of existing pans, components and pieces of an AWWTS that were included in the original design which would allow the AWWTS to continue to perform as designed. E. Permit (Construction) An On-Site Wastewater Disposal System Construction Permit as defined by AMC 15.65. F. Permit (Operating) An Advanced Wastewater Treatment System Operating Permit. An annual permit, issued by the Municipality, that allows the Owner to operate an AWWTS, upon meeting all the requirements of this agreement, the conditions of Operating Permit, the requirements of the On-Site Wastewater System Construction Permit and all relevant provisions of AMC 15.65 3. Fee. O~mer shall pay to Municipality an annual fee of ~-~ r- O ($ ~.00), payable on or before the issuance of the operating permit and annually thereafter. The annual fee is due on or before the anniversary date ofthe approval by the Municipality of installed system. 4. Term. The term of this Memorandum of Understanding shall be for the life of the AWWTS. The term begins on the date of approval by the Municipality of the installed system and shall continue while the AWWTS system is in use or operational or until the proper~y is sold or title is transferred by o~er and a new certificate o£On-Site approval is issued to the new o~er or transferee o£the proper~y. 5. Alteratlons~ Installation and Removal of Afldifional Equipment. Owner agrees not to make any alterations, removal of parts or additions to the AWWTS ~Sthout a Construction Permit from the Municipality. 6. Maintenance and Repairs. A. Throughout the term of this Memorandum of Understanding, the O~mer shall maintain AWWTS in good repair. In addition, it shall be the responsibility Ofthe Owner during the term of this Memorandum of IJnderstanding, and any extensions or renewals thereof, at the o~aaer's sole expense, to pay for any and all: (!) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs. Further, O~mer agrees to comply will all applicable ordinance, laws, regulations, rules and orders for the AWWTS. B. Owner agrees to provide the Municipality a ~xitten schedule of routine maintenance and repairs which have been performed on the system pursuant to the terms and conditions contained in the Owner's AWWTS Operating Permit. This schedule shall be submitted to the Municipality annually upon the renewal ofthe permit. The schedule of maintenance and repair contained in the O~er's AWWTS Operating Permit is: /V~'~r'l~/ C. O~mer acknowledges that the fine schedule for failing to maintain and repair an ^WWTS are codified in AMC 14.60. D. Owner agrees that only maintenance, repair personnel certified by the Municipality will inspect and make any necessary maintenance, repairs or permitted alterations to the system. E. Owmer agrees to grant the Municipality reasonable access to test and inspect the AWWTS upon 24 hours ~itten notice. F. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On-Site Systems Approval. G. Owner agrees that the relevant provisions of the standard specification guidebook · for AWWTS is the governing professional guidelines for the construction, maintenance and repair of the Owner's AWWTS. 7. Nonwalver. The failure of either party at any time to enforce a provision ofthis Memorandum of Understanding shall in no way constitute a xvaiver of the provisions, nor in any way effect the validity of the Memorandum of Understanding or any part hereof, or the right of such party thereafter to enforce each and every provision hereof. 8. Amendment. A. This Memorandum of Understanding shall only be amended, modified or changed by a ~xiting, executed by authorized representatives of the parties, with the same formality of this Memorandum of Understanding was executed and such writing shall be attached to this Memorandum of Understanding as an amendment. B. For the purposes ofany amendment modification or change to the terms and conditions of this contract, the only authorized representatives of the parties are: Anchorage: Purchasine Officer C. Any attempt to amend, modify, or change this contract by either an unauthorized representative or unauthorized means shall be void. 9. Jurisdiction: Cholee of Law. Any civil action arising from this Memorandum of Understanding shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Memorandum of Understanding. 10. Severabilltv. Any provisions ofthis Memorandum of Understanding decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Memorandum of Understanding. .OWNER: ! Title: Date: ~Ofr. /~'[ -?~ 0 0 ~ Date: STATE OFALASKA THIRD JUDICIAL DISTRICT MUNICIPALITY: The foregoing instrumeqt wj~s acknowledged before me this I__~ay of [ei~ ~9t.j.)rL, 20_O~by (-3. m_ L I OoRt ,the OCO J NOTARY PUBLIC' FOR ALASKA My Commission expires: ~'-~