HomeMy WebLinkAboutSKYHILLS PH 1 BLK 1 LT 75kyhills Ph !
Block I
Lot 7
#011-122-18
Permit Number: OSP121080
Tax Code Number: 01112218000
Work Type: Septic
Permit Effective Dates: May 23, 2012
On-Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Initial
to May 23, 2013
Design Engineer: ANDERSON ENGINEERING
Subdivision: SKYHILLS PH 1
Site LegalAddress: SKYHILLS PH 1 BLK 1 LT 7 G:2222
Owner/Address: ENGEL MARTIN A
12031 EDGEWATER CIRCLE ANCHORAGE AK 995153'134
Site Mailing Address: 8206 Skyhills DR, Anchorage
Lot Size in Sq Ft: 57132
Total Bedrooms: 5
This permit is for the construction of:
Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Special Provisions: The permit includes waiver OSP'12108'1 allowing the drainfield to be 30 feet or
more from a slope greater than 25%.
Received By:
Date:
Date:
Municipality of Anchorage
P.O. Box 196650 · 4700 Elmore Road
Anchoraqe, A aska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997
http:llwww.muni.orcllOnaite
Development Services Division
On-Site Water and Wastewater Proqram
**** VARIANCE/WAIVER REVIEW ****
WaiverS: OSP'121081 COSA#:
PID#: 01t-122-18
Legal Description: Skyhills #1, Block '1, Lot 7
Engineer: Anderson En.qineerin.q
Permit: OSP121080
Applicant: Martin A. Enqel
Your request for a waiver of the required 50 feet horizontal separation from the absorption field
to the slope greater than 25% has been approved. The approved separation distance is 30 feet.
This waiver approval applies to the proposed absorption field only. Any future upgrade to the
on-site wastewater disposal system will require all separation distances be met or another
approval from this department.
[] The affected adjacent property owner(s) have been given a 7 day notice regarding this
waiver.
[] Notarized letter(s) of nonobjection have been received from the owner(s) of the affected
adjacent property.
[] Adjacent properties are not affected by this waiver.
Waiver is Granted: X Waiver is not Granted:
Date: ~>'",/'~.c~?/~ Approved by' ~r~.-/~
( / / ~.~r Name of Reviewer
Rec#: 041080 Amount: $200.00 Date Paid: 511512012
**** VARIANCE/WAIVER REVIEW ****
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
MUNICIPALITY OF ANCHORAGE
Mayor Dan Sullivan
Phone: 907-343-7904
Fax:907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Property owner(s):
Mailing address:
Site address:
Parcel I.D. 011-122-18
Martin A. Engel Day phone:
12031 Edgewater Circle Anchorage, AK 99515
Skyhills Drive Anchorage, AK 99515
Legal description (Sub'd., Block & Lot): Skyhills No. 1, Block 1, Lot 7
Legal description (Township, Range & Section)
Lot Size: 57,t32 S.F. Number of Bedrooms: Five (5)
THIS APPLICATION IS FOR:
([~ all that apply)
Absorption Field X
Septic Tank X
Holding Tank []
Privy []
Private Well []
Water Storage []
THIS APPLICATION IS AN:
Initial X
Upgrade []
Renewal []
THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR:
Absorption Trench to Slope >25%.
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number:
Permit No.
530 .¢
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
C:\Users~AndEng\Desktop\Mike\Skyhills\Permit Application L7, Sl,docC:\Users~AndEng\Desktop\Mike\Skyhills\Permit Application
L7, B1 ,doc
ANDERSON ENGINEERING
P.O. BOX 24O773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
May14,2012
Municipality of Anchorage
Development Services Department
OmSite Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Su~e~:
Lot 7, Block 1, Skyhills Subdivision No. 1
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 7, Block 1, Skyhills Subdivision No. 1 intends to construct a new five-
bedroom home on the lot. We are therefore requesting a permit be issued for the
construction of a new septic system to accommodate the home. The subdivision is
currently served by the AWWU Water System. The attached Site Plan and backup
documentation identify the location and configuration of the proposed septic system
along with the alternate site and the proposed water service. No existing wells or septic
systems conflict with the proposed septic system. Drainage arrows are shown on the
site plan showing the grade and direction of flow on the lot. The drainage pattern will
not be changed as a result of this project.
The test holes placed on the lot in the area of the absorption trench and alternate site
indicated silty sand with gravel (SP/SM). The percolation rate in was determined to be
7 minutes per inch. No groundwater was found during the placement of the test holes
and none was noted during the monitoring period. An application rate of .8 gallons per
day per square foot was used in the design of the absorption system. We are
proposing to place a new 1,500-gallon septic tank and a 60' long by 3' wide by 8'
effective depth absorption trench to treat and dispose of the effluent generated in the
house. The elevation of the distribution line in the absorption trench will be 2' below the
surface and the total depth will be 10'. A minimum of 3' of fill or 2" of insulation and 2'
of fill will be placed over the absorption trench and 4' over the septic tank.
The ground surface on the lot in the area of the absorption trench slopes to the east at
a 10% grade. A 50% slope exists near the property line which extends to the dry ditch
approximately 4' below the top of the slope. A slope waiver is attached describing the
slope. The new trench will be constructed parallel with the contours of the slope as
Lot 7, Block 1, Skyhills Subdivision No. 1
May 14, 2012
Page Two
much as possible in conformance with Municipal requirements. The new septic system
will be constructed a minimum of 100' from any surface water and 10' from the
proposed and existing water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
MEMORANDUM
DATE: May 22, 2012
TO:
Jay Crewdson, P.E.
FROM:
Mike Anderson, P.E.
SUBJECT:
Lot 7, Block 1, Skyhills Subdivision No. 1
Septic System Permit No. OSP121080
We have made the following revisions in accordance with your comments:
1. Subsurface soils throughout Skyhills Subdivision are very consistent and include
well graded sand with some silt. In almost every case the percolation rate is less
than 5 minutes per inch. This system is designed for a slower percolation rate of
between 6 and 15 minutes per inch. Test Hole No. 63 on this lot is primarily
sand with a percolation rate of less than 5 minutes per inch. We are confident
the subsurface soils in the area between TH 62 and TH 63 are consistently clean
sand.
2. The alternate site has been redesigned and moved to provide additional
separation distance from the break in grade. At the new location the break in
grade is much less dramatic. Placing the alternate site at this location will result
in the imaginary 25% slope not daylighting.
3. The retaining wall is shown on the Site Plan. The primary absorption trench has
been moved to the south and is now nearly 22' from the property line. At its
closest point it is nearly 35' from the retaining wall. The imaginary 25% line does
not daylight when extended toward the retaining wall. The CPP found in the
drainage ditch appears to be a culvert under the driveway. The ditch and culvert
have remained dry over the past two weeks, the
wettest period of he year.
This ti[r~e~,pe~ io~i~ typically
.....
uJ
Zm
'i~IS3 3lin ,Ol
iCL'G6L N~,,6g,~L.O0 N
7
I
n
IJJ
I I
LOT 7, BLOCK 1, SKYHILLS SUBDIVISION NO. 1
DESIGN FACTORS:
Five Bedroom House
Perc. Rate: 7 Min./Inch
Application Rate: .8 GPD/SF
SYSTEM REQUIREMENTS:
Deep Trench System
1,500 Gallon Septic Tank
8' Drainfield Rock
5 Bedrooms X 150 GPD/.8 GPD/SF (Application Rate) = 937.5 SF Absorption Area
937,5 SF/16 SF/LF = 58.6 LF Trench Length
THEREFORE: Construct a 60' Long x 3' Wide x 8' Effective Depth Aborption Trench at the
Location Shown. Flow Line Elevation in Trench to be 2' Below Original Ground Surface. Total Depth
to be 10' Below Existing Ground. Provide 3' of Cover Over Trench and 4' Over Tank or Provide
2" of Insulation and 2' of Cover. Maintain 10' Separation From Water Services in the Area.
~'~N at u ral~"~"~%
Backfill
Geotextile
-- Fabric
4" Perforated
~. o PVC (Holes Down)
-- Drainfield Rock
31
TYPICAL DEEP TRENCH SECTION .
__--.----~~ --
NOTE: Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock ...... ~ .....~ ....................... ...,..~
Minimum 4' Separation From Groundwater.
Minimum 200, Separation From Class A Well in the Area.
Minimum ~0~ Soparation From Surfaco Water or Stroams.
Minimum ~ 0 Soparation From Water Se~ico Une.
MUnicipality of Anchorage.
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 ....
L Street, Anchorage, Alaska 99502-0650
PERFORMED FOR:
LEGAL DESC tl
SOILS LOG -- PERCOLATION TEST
L E Cozzst, ruction
DATE PERFORMED:
LEGAL DESCRIPTION:. !r.T-~f ]mit/ s~_ E±~ls itzbd±vlslon
~ SLOPE SITE PLAN
WAS GROUND WATER ~
ENCOUNTERED? -
IF YES, AT WHAT /
DEPTH?
Menitoriag? a~ ~
[ COMMENTS Perc cavity
[ ~ PERFORMED
S
L
Reading Date Gross Net Depth to Net
j Time Time Drop
PERCOLATICN PATE
TEST RUN BETWEEN
presoaked
-- (mmutes/mchl PERC HOLE DIAMETER
FT AND ,, ~ FT
I ~±chael E AndersoC~ERTIFY THAT THiS TEST WAS PERFORMED IN
ACCORDANCE W~TH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE DATE: --
PERFORMED FOR:
LEGAL DESCRIPTION:
1
2
3
4
5,
6-
7
8
9
10
11
13-
14-
15
16
17
18
19-
20-
COMMENTS
Municipality of Anchorage
.
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Strut, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCO~TION TEST
L H Construction
LT~ BLK~! Sky Hills Subdivision
SLOPE SITE PLAN
WAS GROUND WATER
ENCOUNTERED?
IF YES. AT WHAT
DEPTH?
I]e~tll ~o Water
MoniWing?
Reading Date Gross Net Depth to Net
Time Time Water Drop
-~1~1~ i ~0~
PERCOLATION RATE
TEST RUN BETWEEN
cavity was oresoaked
(m~nutes4nct~) PERC HOLE DIAMETER
J '~""/"' ' ~ Michael E AndersoCnERTIFY THAT THiS TEST WAS PERFORMED
PERFORMED
BY:
ACCOROANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE, DATE:
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
May 14,2012
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
Lot 7, Block 1, Skyhills Subdivision No. 1
Absorption Trench to Slope Waiver
Dear Onsite Services Engineer:
A dry ditch was constructed along the frontage of Lot 7, Block 1, Skyhills Subdivision
No. 1 during the subdivision development and the construction of Skyhills Drive. The
backslope of the ditch is approximately 2:1. The top of the slope is 30' from the closest
edge of the proposed absorption trench and 14' from the closest edge of the alternate
trench.
The subsurface soil on the lot is clean sand with percolation rates between 2 and 7
minutes per inch. It is unlikely that septic effluent will ever migrate to and surface on
the backslope of the ditch.
Sincerely,
Michael E. Anderson, P.E.
e.cD ........... ~e
CD
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 7, BLOCK 1, SKYHILLS SUBDIVISION NO. I
GENERAL:
The scope of this project includes the procurement and placement of a new
1,500-gallon septic tank at the location shown on the Site Plan. Work also
includes the construction of a 60' long by 3' wide by 8' effective depth
absorption trench also at the location shown on the plan. The distribution line
in the trench will be placed at 2' below the existing ground surface. Total
depth of the trench will be 10' below the existing ground surface. The new
absorption trench must be placed a minimum of 10' from all water services in
the area and 100' from any surface water in the area. A minimum of 3' of
cover is required over the absorption trench and 4' of cover over the septic
tank.
Construction shall be in accordance with the approved site plan, design
drawings, Municipal Permit with any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal Regulations,
The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the location
of all lot lines. The Contractor must also verify the location of wells in the
area and assure that the separation distances are met. The Contractor must
provide field survey notes to verify the layout of the septic system and to
ensure no encroachment into easements or lot line setbacks.
Unless specifically agreed otherwise, the contractor shall be responsible for
final grading areas subsequently depressed from soil settling. Property
owner shall be responsible for revegetation of affected areas unless
specifically agreed otherwise.
Contractors installing wastewater disposal systems must be certified by the
Municipal Department of Building Safety On-Site Water and Wastewater
Program for system installations. Owners installing their own systems must
receive prior approval from the On-Site Water and Wastewater Program
before beginning system installation.
SEPTIC TANK INSTALLATION
1. A new 1,500 gallon septic tank must be procured from an approved source
and installed at the location shown.
2. A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
Lot 7, Block 1, Skyhills Subdivision No. 1
May 14, 2012
Page 2 of 3
3. The septic tank shall be sufficiently bedded to prevent settling or shifting of
the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches above
final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial
insulation.
6. A foundation cleanout shall be installed one to four feet from the building
foundation. Two cleanouts are required between the tank and the drainfield.
7. Final grading over the tank shall be such that a ~ositive slope exists away
from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the design.
The bottom of the trench shall be within 2" of level.
Distribution piping must be placed level with perforations down atop a level
bed of drainfield rock. Rock should then be placed over the pipe to provide a
minimum of 2" of cover,
3. A silt barrier or geotextile fabric must be placed between the drainfield rock
and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations shown on
the design. The portion below the distribution line must be perforated.
Contractor shall verify the septic tank and drainfield are a minimum 100' away
from any private water wells in the area, 150' from a Class "C" Well or 200'
from any community well.
Direct bury insulation must be placed over the distribution system if less than
3' of backfill depth is available. Finish grade over the trench must be
mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away,
A minimum 2' of accepting soil is required below the drainfield rock for
absorption trenches, All pockets of unacceptable materials must be removed
and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic tank
manufacturer.
Lot 7, Block 1, Skyhills Subdivision No. 1
May 14, 2012
Page 3 of 3
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and
solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662
orA. B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow
Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the
#200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These inspections
must be conducted under the supervision of a professional engineer registered
in the State of Alaska. The first inspection must be conducted after the
excavation of trenches, beds or pits and before the installation of any gravel. A
septic tank may be set in place, but may not be backfilled
The second inspection must be conducted after the placement of the geotextile
fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No
backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction notes
for use in preparing the certified as-built of the completed system. In addition,
the property owner must furnish an as built of the lot showing the location of the
house, septic system and other aboveground features.
�'�6'j a 9'0772
ti A�
k
r 4 .
CL SEP WWfie.
On -Site
Aj
6 w
ZZ C� �\
Parcel I. D. 011-122-18
duty of Anchorage
:r and Wastewater Program
(907)343-7904
69bg
e i icate of On -Site Systems Approval
1. GENERAL INFORMATION:
Complete legal description Skyhills Phase 1: Block 1, Lot 7
C.n CC,
�£84
r i
p .0
U 4
<r n
S A I E T Y
Expiration Date: �3 ^ ! J + 02D
Location (site address) 8206 Skyhills Drive *Anchorage, AK 99502
Current Property owner(s) Matthew & Ann Waldron Day phone
Mailing address
Real Estate Agent
8206 Skyhills Drive *Anchorage, AK 99502
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
Day phone
3. NUMBER OF BEDROOMS:
5
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
❑
Individual
Individual Water Storage
❑
Holding Tank
❑
Community Class Well
❑
Community
❑
Public Water System
®
Public Sewer
❑
WaiverNariance request for:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm: Garness Engineerinq Group, Ltd (GEG) Phone: 907-337-6179
Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507
Engineer's Printed Name: Jeffrey A. Garness
Date: a Z li
In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system
in accordance with the guidelines and regulations established by the Municipality of Anchorage and
industry practices. The reported results describe the condition of the system/s on the date/s of the
evaluation. Separation distances were measured to readily identifiable features. Hidden defects or
encroachments may exist that were not identified during the evaluation. The operational life of all wells
and septic systems depend upon a variety of variables, including but not limited to, soil conditions,
groundwater levels (that may fluctuate during the year), quality of construction (materials and
workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and
are outside the control of GEG. Satisfactory test results do not guarantee future performance of the
system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of
the well or septic system. GEG makes no representation whether an alternative well or septic system
can be installed on the property in the event either of the current systems fail to perform adequately in
the future. The content of this report is for the sole benefit of the person/party that retained GEG to
perform the evaluation. Reliance upon the information provided in this report by any other person or
party (including subsequent property purchasers) is not authorized, nor will it confer any legal right
whatsoever.
#AECC884
6. DSD SIGNATURE ',
System #1 Approved for bedrooms `�����`� OFy0/����/
System #2 Approved for bedrooms VN.
�
Disapproved
PEER Q
Conditional approval for bedrooms, with the followt� stip kg ee P�
�% PR®C'R _
11)))))1111
Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineers work.
7. ATTACHMENTS:
COSA Checklist Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet 10-10-12.doc
Legal Description: Skyhills Phase 1; Block 1, Lot 7
If more than 1 septic system on lot: COSA Checklist # of
A. WELL DATA
❑ Well log is filed with Onsite (or attached)
Date drilled
Total depth ft
Cased to ft
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected /
Casing height (above ground) in.
Date of flow test for CO
Static water at beginning of test ft.
ents
Parcel ID: 011-122-18
Structure served by this system
Well production at time of test gp
Water storage tank volume _ gallons
Well disinfected fo orm test? ❑ Yes ❑ No
❑ Col' acteria is Negative
itrate mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L ❑ Arsenic less than MRL (ND)
Collected by
Date of Sample
B. TANK DATA C. LIFT STATION
Age of tank(s) 7 years ❑ Required maintenance completed
Tank type/material septiUsteel Age of lift station years
Measured operating fluid level in septic tank *37" Lift station material
FO -1 Standpipes/foundation cleanout per record drawing Comments -
Date of pumping 8/27/19
*Home has not been occupied since around the time of pumping
D. ABSORPTION FIELD DATA
Which system tested (date installed) 2012
❑ ALL standpipes present per record drawing
Total measured depth from grade 10.6 ft (max)
Measured depth to pipe invert from grade 3.6+ ft (min)
❑ N/A — pressurized field
❑ Monitor tubes go to bottom of effective. If not, state
depth into effective 7'
❑ Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced - gallons
Comments/Deficiencies: 'The last Z8 gallons introduced only caused a
COSA Checklist yellow sheet
Adequacy test date 3/13/18
Results ❑✓ Pass For 5 bedrooms
Fluid depth prior to test 42 in
Water added *933 gal
New depth 59 in
Elapsed time 120 min
Final fluid depth 53 in
Absorption rate 750+ gpd
Any rejuvenation treatment (past 12 months)
If yes, enter date -
rise of 7 inches.
m
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
Yes
Community Sewer Manhole/Cleanout >
ft
❑ Yes
if No ft
es
if No ft
Neighboring Tank > 100' ❑ Yes
if No ft
Private Se eptic Line > 25' ❑ Yes
if No ft
Absorption Field on Lot > 100' ❑ Yes
if No
Holding Tank > 100' ❑ Yes
if No ft
Neighboring Absorption Fields > 10 '
❑✓ Yes if No ft
Animal Containment > 50' ❑ Yes
if No ft
Yes
if No ft
Community Wells > 200'✓❑
Yes if No ft
Water Service Line > 10'
Q Yes
Manure/Animal Excreta Storage > 100'
ft
Comm ewer Main > 75' ❑ Yes
if No ft
❑ Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
Yes
if No *5+
ft
Surface Water > 100'
Yes if No ft
Property Line > 5'
Yes
if No
ft
Wells on Adjacent Lots:
Wells on Adjacent Lots:
Absorption Field > 5'
Q Yes
if No
ft
Private Wells > 100'
❑✓ Yes if No ft
Water Main > 10'
Q Yes
if No
ft
Community Wells > 200'✓❑
Yes if No ft
Water Service Line > 10'
Q Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
❑
Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
Q
Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'
Q
Yes
if No
ft
Private Wells > 100' IO Yes if No ft
Water Service Line > 10'
r❑
Yes
**
if No
ft
Community Wells > 200' Q Yes if No ft
Surface Water > 100'
❑r
Yes
if No
ft
F. ENGINEER'S COMMENTS
*Met code at time of installation
**Assumed per AWWU keybox location/Onsite Department record drawings.
G. ENGINEER'S CERTIFICATION o OF gpQ4
I certify that 1 have determined through field inspections and review O Q
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
O '.Je f y A. orne
—79
COSA Checklist yellow sheet 404a Profess 000
#AECC884
• Municipality 6 •
• � ? 8 9 ,....q.:
e ,rri_ � of Anchora e �u5 r _
o
On-Site Water and Wastewater Program ,`-‘' ; „1!�w�•� <�•>;.,,ii 1-6 Z
(907) 343-7904
ETY
0 MAR 1'9 2u,_ Ill
x
Certificate of On-Site Systems Appr.
Parcel I.D. 011-122-18 Expiration Date:
1. GENERAL INFORMATION:
Complete legal description Skyhills Phase 1; Block 1,Lot 7
Location (site address) 8206 Skyhills Drive*Anchroage,AK
Current Property owner(s) Joshua&Stacey Logan Day phone 678-617-7283
Mailing address 8206 Skyhills Drive*Anchorage,AK
Real Estate Agent Natalie Lewis Day phone 865-6406
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 5
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well 0 Individual
Individual Water Storage 0 Holding Tank 0
Community Class Well ❑ Community ❑
Public Water System ® Public Sewer ❑
WaiverNariance request for: Distance:
4 Received by: Date: 31za l
COSA to be released to the engineer,unless otherwise requested by the engineer.
COSA Fee $ 5z c Waiver Fee $
Date of Payment 3 17—i 11? Date of Payment
Receipt Number 0�c-r161 Receipt Number
COSA# 65G 1l DCt t Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179
Address: 3701 East Tudor Road,Suite 101-Anchorage, Alaska 99507
Engineer's Printed Name: Jeffrey A. Garness Date:
a00000�0
In conducting this evaluation,GEG provided an engineering evaluation of the well and/or septic system o OF A / 004
in accordance with the guidelines and regulations established by the Municipality of Anchorage and ,.• '•'•• •.,• 11 s ki
industry practices. The reported results describe the condition of the system/s on the date/s of the QkoP..' 7v On
evaluation. Separation distances were measured to readily identifiable features. Hidden defects or aQQ� ; AVO
encroachments may exist that were not identified during the evaluation. The operational life of all wells H
' ' 9 D
and septic systems depend upon a variety of variables, including but not limited to, soil conditions, •••.•••• •• •• •
groundwater levels (that mayfluctuate duringthe year), '
quality of construction (materials and � /
workmanship),and the water usage of the family utilizing the system/s. These conditions can vary,and j .t/,fVA
are outside the control of GEG. Satisfactory test results do not guarantee future performance of the Q '•J fr-, k . ness."
system/s;therefore, GEG makes no warranty(express or implied)regarding the future performance of 0011. E-179531
the well or septic system. GEG makes no representation whether an alternative well or septic system s �Q
can be installed on the property in the event either of the current systems fail to perform adequately in 'J ,. Z •�•V cc:\c
the future. The content of this report is for the sole benefit of the person/party that retained GEG to professionoo�o
perform the evaluation. Reliance upon the information provided in this report by any other person or ��DOp000�
party (including subsequent property purchasers) is not authorized, nor will it confer any legal right
whatsoever.
#AECC884
6. DSD
SIGNATURE
System #1 Approved for bedrooms
System #2 Approved for bedrooms
Disapproved \1Y OF�- 'mac
ti
Conditional approval for bedrooms, with the follg stipulations: O
CPN-SITE 0
WATER AND rn
c WASTEWATER z
cq. PROGRAM
v7 CD
4rp\I\CJ
By: ! vv`- f Original Certificate Date: 3 -
/
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The
Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist )(I Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet_10.1 O.12.doc
If more than 1 septic system is on the lot:
COSA Checklist # of
Structure served by this system
Certificate of On-Site Systems Approval Checklist
Legal Description: Skyhills Phase 1; Block 1, Lot 7 Parcel ID: 011-122-18
A. WELL DATA PUBLIC
Well type If A, B, or C provide PWSID# Well Log (Y/N)
Date completed Sanitary seal (Y/N) Wires properly protected (Y/N
Total depth ft. Cased to ft. Casing height (abo - .round) in.
FROM WELL LOG AT I .` CTION
Date of test _—
Static water level ft. ft.
Well production g.p.m. g.p.m.
WATER SAMPLE RES " :
Coliform colonies/100 ml. Nitrate mg./L. Collected by:
enic: ug./L. Date of sample:
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/Steel Date installed 6/8/2012
Tank size 1500 gal. Number of Compartments 2 Cleanouts (Y/N) Yes
Foundation cleanout (Y/N) Yes Depression over tank (Y/N) Na High water alarm (Y/N) N/A
Date of pumping 3/15/2018 Pumper Alaska Quality Septic
C. ABSORPTION FIELD DATA *Below Existing Grade ® MT
Date installed 6/8/2012 Soil rating kp.d./for ft2/bdrm) 0.8 System type . Deep Trench
Length 61 ft. Width 3 ft. Gravel below pipe **8 ft.
Total depth *10.7+ ft. Eff. absorption area 976 ft2 Monitoring tube Yes Depression over field No
Date of adequacy test 3/13/2018 Results (Pass/Fail) Pass For 5 bedrooms
Fluid depth in absorption field before test 42 in. Water added***933 gal. New depth 59 in.
Elapsed Time: 120 min. Final fluid depth 53 in. Absorption rate >= 750+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) None Known If yes, give date —
**MT extends approximatley 7 feet into drainrock
***The last 408 gallon introduced only caused a liquid rise of 7 inches
D. LIFT STATION
Date installed Size in gallons Manhole/Access (Y/N)
"Pump on" level at in. "Pump off" level at in. High water alarm level at in.
Datum Cycles tested Meets alarm & circui -.uirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO: PUBLIC
Septic tank/lift station on lot On adjacent lots
Absorption field on lot On adjacent lots
Public sewer main Public sewer manhole/cleanout
Sewer/sep -rvice line Holding tank
e • al containment areas Manure/animal excrete storage areas
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+ Absorption field 5'+
Water main 10'+ Water service line 10'+ Surface water 100'+
Wells on adjacent lots 100'+PVT (Sc 200'+PUBLIC
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 10'+ Water main 10'+
Water service line *1 O'+ Surface water 100'+ Driveway, parking/vehicle storage **
Curtain drain None Known Wells on adjacent lots 100'+PVT & 200'+PUBLIC
F. COMMENTS
*Assumed per AWWU keybox location/Onsite Dept. record drawings.
**Due to piled snow, (cOMR separation from drainfield to driveway/parking area could not be confirmed.
oQo�00Q�O
G. ENGINEER'S CERTIFICATION OF... 4 e iN
QvP,� •.'9s�Qoo
Qom..••• ••� 0
I certify that/have determined through field inspections and ;' 49- Q
review of Municipal records that the above systems are in VA
conformance with MOA COSA guidelines in effect on this Q I Q
date. • i``.�� p
f �.- .rness;•
Engineer's Printed Name JEFFREY A. GARNESS 0049,; CE 795 \ceQQ�
Date 3/-40/!� (i •.3f�•zp1).( o0
4kci Pr 'on&
#AECC884