HomeMy WebLinkAboutWOODHAVEN #3 LT 8 Municipality of Anchorage Community Development Department Page 1 of 3 On-Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite• (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP171047 PID Number: 015-282-53 ❑✓ New ❑ Upgrade Name: Spinell Homes Inc. ABSORPTION FIELD Address ❑ Deep Trench ❑✓ Shallow Trench ❑ Bed 0 Mound 3850 Marcelle Circle ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 5 2 GPD/SF 4.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 2.0 Ft. 2•0Ft. Woodhaven #3 8 Fill added above original grade Gravel length Township Range Section 0.75 Ft. 40/40 Ft. Gravel width Beds:Number of Lines 'Distance between lines SEPARATION DISTANCES 5.OFt. N/A N/A Ft. To Septic Absorption Lift Station' Holding Sewer Total absorption area Number of trenches Dist.between trenches From Tank Field Tank Line 571 Ft2 2 17.3 Ft. Well 147.7 146.6 147.7 N/A 25+ TANK ❑Septic 0 S.T.E.P. ❑Holding C Other Manufacturer Capacity Surface Water 100+ 100+ 100+ N/A Anchorage Tank/Orenco 2500Gal. Material Number of compartments Lot Line 58.6 19.6 58.6 N/A STEEL 2 NA Foundation 38.8 45.4 38.8 i N/A LIFT STATION Manufacturer Capacity Curtain Drain 50+ 50+ 50+ N/A Orenco 750 Gal. Remarks Pump on level at Pump off level at High water alarm at 40 in. 36 in. 45 in. Pump make and model Electrical Inspections performed by P2005 MoA Building Safety PIPE MATERIAL House to tank 3034 Tank tod 3034 drainfiel Installer Pomraining Construction Drainfield 3034 CO/MT 3034 Inspector Pannone Engineering Services BENCH MARK (Assumed elevation) 368ft Inspection 1s' 11/17/17 Location and description dates: 2nd11/20/17 3r0 11/22/17 a`h NW Bottom Trim COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Aus OFAt 71k1 Conditional Approval: Date ''• 1 P• - j*'•4 • T�-I i' *�0/ ... �. / •• ci bteveri ' Pannone'% / l,• E 814 Aer 'Oh"'341-0(7—.VA° Approved '. I I a Date 1 11-F 1\i\\\ 0A4� Inspection Report_1-1-12.doc DESIGN PARAMETERS (E) al PRIMARY/RESERVE SEPTIC SYSTEM 17-1TH- 8 NO. BEDROOM: 5 (750 gpd) TANK SIZE: 2500g ADVANTEX WELL (E) W/ (2EA) AX20 PODS r 1 I'll) PERC RATE: 60 MPI \ SOIL RATING: 2 GPD/SF �p g AREA RQD: 375 SF SYS. TYPE: WIDE TRENCH 2.O'EDM\M r M �41 RF: 0.70 MIN LENGTH: 52.5 LF ‘i- is \ •- V \ USED: II/(2EA) 40 LFx5'Wx2.O' E.D., 4.0' TD \ TOTAL AREA: 571 SF W I INSTALLED PRIMARY DRAINFIELD 4OLF x 5'W x 2.O'ED x 4.O'TD INSTALLED MONITOR TUBE / \ ....------ J� AND CLEAN OUT AT EACH END • 10' T&E EASEMENT l. 10' T&E EASEMENT• i0 ' 24. • g c1 w W WELL (E) 146.6 M1 w / DCO 147.7 M2 / Fo-S-TH-9 A I C2i >� \ NEW I 1.2Wil• LOT 8 /M3 LS T1 B SBD A B n • TH-1 I I I Ti 44.7 40.60 • ca I I !y\ Cl 47.1 54.4 19.6 U INSTALLED 25009 ADVANTEX TANK C3 96.8 93.1 • WITH (2EA) AX20 PODS _ INSTALLED FOUNDATION CLEAN OUT 'ABBREVIATIONS DOUBLE CLEAN OUT, AND FLOW SPLITTER TEST HOLE WETLANDS (P) PROPOSED 9 NO SURFACE RESERVE DRAINFIELD (P) WATER WITHIN 4OLF x 5'W x 2.0'ED x 4.0'TD (E) EXISTING INSTALL MONITOR TUBE CO CLEAN OUT NO. 100' • AND CLEAN OUT AT EACH END MT MONITOR TUBE NO. I TYP TYPICAL •. 5 0 2 z s q w m FILTER FABRIC, -0 N SS }N 5 r DRNN ROCK 6'ABOVE PIPE INV 1d 0 llC c‘10 p 4'0 DRAIN PIPE Z: SU e U 2 AX20 AX20 §'' POD POD /ral I ova �` _ 2.0 :2.0 2500g S.T.E.P. - - 4.0 SAI 360.4 TANK T 1 360 T2 358 -10.0 TRENCH SEIE UES6N 2.0 T1 360 -10.011/17/17 11/24/17 12 358 -- -12.07/8/13 PROFILE T1 358 SCALE: NTS T2 356 -15.5 NOTES: ��.���\ Dote RECORD DRAWINGPtN�NE ENG SVC, LLC OF At. 1/26/2018 P.O. BOX 100217 ANCHORAGE, AK 99510 �,�Q� . .s,t( 1/26 PHONE (907) 272-8218 FAX (907) 272-8211cale 000;*.49 *�/, 1"=50' 0 P.I.D. NO WOODHAVEN #3, LOT 8 / 015-282-53 SPINELL HOMES, INC. R. annone ' PERMIT NO. DRAWN BY ACP 4 /(3c. CE 8149 ••c�j TEST HOLE 1 SOILS LOG - PERCOLATION TEST �// SLOPE SITE PLA, 1 OR/ ORGANICS/ _--/ e OL ORGANIC SILTS =MENT . — _MENT• 2 3 4 /J 5 4 o---T H-9 6 SM SILTY SAND x >'�r \ TH3n \ , 7 �Z TH-1-1 I I I 8 - 9 lU l l I I �\ 10 U 4 /L BOH 11 — . _.. • 12 WETLANDS 13 - WAS GROUND WATER SLOPE 14 ENCOUNTERED? Y 15 IF YES,AT WHAT TH DEPTH? -10.0' x 16 17 DEPTH TO WATER AFTER MONITORING? -10.0' 18 DATE: 11/24/17 —_ WATER 19 READING DATE CLOCKT IME NET TIME LEVEL NET DROP READING DATE PERFORMED:11/17/17 1 11/22/17 10:55 --- 5.10 --- 2 11:05 10 MIN 9.88 4.78 3 11:05 --- 5.10 --- 4 11:15 10 MIN 9.30 4.20 5 11:15 --- 5.10 -- 6 11:25 10 MIN 9.05 3.95 7 11:25 --- 5.10 --- 8 11:35 10 MIN 9.02 3.92 PEROLATION RATE 2.55(min/inch)PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 3 FT AND 4 FT COMMENTS:Test hole excavated by POMRAINING CONSTRUCTION PERFORMED BY: Dan Moran. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. NOTES: .���.��\\� Date PANNONE ENG SVC, LLC — of A/ -i 1 i26i20, RECORD DRAWING P.O. BOX 100217 ANCHORAGE, A 99510 r P'&• :40.ki PHONE (907) 272-8218 FAX (907) 272-8211 //c,-.. �4_..1-....,14 Scale iii ��• NTS 1 .. ••/F P.LD. NO WOODHAVEN #3, LOT 8 ,,,, . ,,, •., ' - 82-53 SPINELL HOMES, INC. dS•teven F2. 'onnorae PERMIT NO. DRAWN BY ACPCLE ��c, CE 8149 ��/� OSP171047 PLAN ANCHORAGE, AK +TOk A,b • fESS10NP�*� Sheet 1���"\"`*� 3 OF 3 Certified DrillingUg DOC CO dba BILL 8. COLE ► WELLSULLIVAN WATER ler P.O.Box 670269, Chugiak,AK 99567 688-2759 OWNER OF LAND: Spinell Homes Bore Hole Data ADDRESS: 1900 W. Northern Lights Blvd#200, 99517 Depth LEGAL DESCRIPTION Woodhaven#2 D-1B-A Lot 8 From To DATE: 9/15/14 0 2 Casing stickup PERMIT NUMBER: OSP141148 DATE OF ISSUE: 8/21/14 2 4 Overburden TAX IDENTIFICATION NUMBER 015281870000155-282.-53) Is well located at approved permit location: WYes nNo 4 21 Silty sand &gravel Method of Drilling: Nair rotary ncable tool 21 26 Sand &gravel w/Water Depth of Well: 118' 26 62 Hardpan Casing Type: Steel Wall thickness .250 inches 62 64 Sand gravel & Water Diameter: 6 inches, depth 118 feet 64 103 Hardpan Liner type None Static Water Level: 40 feet 103 110 Tight sand &gravel Recovery Rate 10 ® gpm n gph 110 118 Sand gravel &Water Method of Testing Well Intake Opening Type: M open end reopen hole n Screened Start feet Stopped n Perforations Start feet Stopped Grout Type: Bentonite chips Volume: 100 lbs Depth:from 2 feet,to 20 feet Well Disinfected Upon Completion: Eyes n no Method of Disinfection: Chlorine 50 PPM Comments: Well# 1 WATER QUALITY TESTING CdHtxm N G Co1/100mL Nitrates 1•1D mg/L Arsenic t•%b L 'i3)2016 Drillers Name: Cole Sullivan ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough: Department of Environmental Conservation. DOC CO dba 0111BILL i COLE joULLIVAN WATER WELLS P.O. Box 670269, Chugiak,AK 99567 688-2759 www.sullivanwaterwells.com Pump Installation Log Well Drilling Permit Number:SW OSP141148 Date of Issue 8-21-14 Parcel Identification Number: -01-52848-7000 0 15 - 232 - 53 Legal Description Property Owner Name&Address Woodhaven#3 Lot 8 Spinel'Homes Pump Installation Date: 9-29-17 Pump Intake Depth Below Top of Well Casing: 90 feet Pump manufacturer's Name: Grundfos Pump Model: 10SQE05-160 Pump Size: 1/2 hp Pitless Adapter Burial Depth: 10 feet Pitless Adapter Installer: Pomraning Excavation ## Disinfected Upon Completion? ® yes no Method of Disinfection: Chlorine 50 PPM Comments: Pitless Manufacturer: Martinson Pump Installers Name: Sullivan Water Wells Attention:The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. On-Site Water System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP141148 Tax Code Number: 01528187000 Work Type: Well Permit Effective Dates: August 21, 2014 to Design Engineer: ANDERSON ENGINEERING Subdivision: WOODHAVEN #2 Site LegalAddress: WOODHAVEN #2 TR D-1B-A G:2735 Owner/Address: SPINELL HOMES INC Initial August 21, 2015 1900 W NORTHERN LTS BLVD #200 ANCHORAGE AK 995173342 Site Mailing Address: 11740 ELMORE RD, Anchorage Lot Size in Sq Ft: 861890 Total Bedrooms: 4 This permit is for the construction of: N Disposal Field N Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: ~ ~ ~ ~ 5 MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Pamel I.D. 015-281-87 Phone:907-343-7904 Fax:907-343-7997 SUBMITTA 2014 Gretchen Stuller Property owner(s) Spinell Homes, Inc. Day phone 344-5678 Mailing address 1900 W. Northern Lights Boulevard, Suite 200 Anchorage, AK 99517 Site address 11311 Polar Drive Anchorage, AK 99516 Legal description (Sub'd., Block & Lot) Woodhaven, j)~YI'. No. 2, Tract D-1B-A Legal description (Township, Range & Section) Lot Size 40,006 .Sq. Ft. Number of Bedrooms Four (4) (Lot 8) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (F~ all that apply) Absorption Field [] Initial [] Single Family (SF) [] (w/wo ADU) Septic Tank [] Upgrade [] Duplex (D) [] Holding Tank [] Renewal [] Multiple Dwellings [] Pdvy [] (SF and/or D) Private Well [] Water Storage [] Dis tance: THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) 2t5- Waiver Fees: Date of Payment: Receipt Number: Waiver No. Permit/Rush Fees: Date of Payment: Receipt N umber: Permit No. Permit App_9-1-12.doc August 18, 2014 Building Safety Division On Site Water and Wastewater Program 4700 Elmore Street Anchorage, AK 99507 Attention: Jay Crewdson, P.E. On Site Services Engineer Subject: Woodhaven Subdivision Aquifer Study Dear Jay: Woodhaven Subdivision is composed of 13 Lots and 2 tracts and is located off of Elmore Road near Huffman Road in Anchorage. It is surrounded by developed lots served by both the AWWU water system and on site private wells. The lots proposed for the subdivision are in excess of 40,000 square feet and are proposed to have on site wells and septic systems. Three wells are proposed for placement in the subdivision on proposed Lots 6, 7 and 8. The wells will be placed at sites which will represent standard locations relative to septic system sites and home sites on typical lots in the subdivision. Each well will be pumped in accordance with AMC 15.55.060F1 to establish the sustained yield as determined by the well driller. Water quality testing from each well will be accomplished in accordance with AMC 15.55.060F2. A formal report including sustained yield results for each well will be submitted once all data is gathered and analyzed. Permit applications are attached for placement of the three wells in the subdivision. We hereby request your approval to complete the well and water study to determine the capacity of the aquifer to support the proposed wells for the subdivision. The location of the wells and the proposed location of the houses and septic systems on the lots will not impact adjacent properties. If the wells and proposed septic systems are constructed in accordance with our design the following statements apply: The well, if constructed as designed, will have no adverse impact on the wells in the area er those to be constructed in the future. The well, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. Woodhaven Subdivision August 18, 2014 Page 2 The well, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The well, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments U N S U B O IVI D E ~ N O. 3 T F 9 r SlEFKIER I ---'~---~ t I L ! ~.~. U N S U(3 DIVIO E D WOODHAVEN SUBO. ADDN. NO. 2 1 WOO DHAVEN S U 8 D. A D D N. I WELL j E N K , NI S U B D. ITS H E P H E R D 0 Fm HE HILLS SUB I I I /// k ~ I / WOODHAVEN SUED.I ADDN. NO. 2 AD NO. 2 AND SEPTIC SYSTEM PLAN SCALE 1" = 200' / I / ~ / / -- WEST / / ~. // / I SUBD. II ~ m m I I ~ ' / I I ~ ~ / ~, ~.t I / LEGEND ~'~' Test Hole Deslgnotion and Location ~1 Well Location with 100' Protective Radius WOODHAVEN SUBDIVISION, ADDN. NO. ,3 LOTS 1 THRU 1,3, TRACTS A & B A RESUBOIVISION OF' TRACT D-1B-A. WOODHAVEN SUBDIVISION. AOON. NO. 2 (84-85), LOCATED WITHIN THE SE1/4, SECTION 21, T12N, R.1W, SM, ALASKA, ANCHORAGE RECORDING DISTRICT, THIRD JUDICIAL DISTRICT, AND CONTAINING 19.79 ACRES, MORE OR LESS. LOT 8, WOODHAVEN SUBDIVISION NO. 3 Test Hole No. 9 DESIGN FACTORS: SYSTEM REQUIREMENTS: 4 Bedroom Home Shallow Bed System Perc. Rate: 60 Min./Inch Four Bedroom Advantex Treatment System Application Rate: 2 GPD/SF Add On Pump Vault .5' Effective Depth 4 Bedrooms X 150 GPD/Bedreom = 600 Gallons 600 Gallons/2 GPD/SF/10 LF (Width) = 30 LF Bed Length THEREFORE: Construct a 30' Long by 10' Wide by .5' Effective Depth Absorption Bed at the Location Shown on the Site Plan. Distribution Pipe to be Placed at 3.5' Below Existing Ground. Total Depth to be 4.0' Below Existing Ground. Place 3' of Cover Over Absorption Bed and 4' of Cover Over Septic Tank. Maintain 100' Separation From Private Well on the Lot. Existing Ground 3,0~ Natural Backfill Geotextile Fabric 0 ,,, 0 ~ Drainfield Rock In Situ GM Soil Existing Ground 10 3/16" Diameter Holes @ 1' Spacing 1' 4' 4' 1' NOTE: TYPICAL BED SECTION (NO SCALE) Grade Area Surrounding Bed to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Private Wells in the Area. Minimum 100' Separation From Surface Water or Streams. Minimum 10' Separation From Water Service Line. 4700 DEPTH (~et) 1 2 3 4-- 5 6 7-- $ 9 11 20¸ MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT BRAGAW STREET ANCHORAGE, AK 99519-6050 SOILS LOG - PERCOLATION TEST WOODHAVEN SUBDIVISION NO. LEGAL DESCRIPTION: PERFORMED FOR: DATE: II;P_211,5 PARCEL ID#: SPINELL HOMES ?ROJECT No.: TECHNICIAN: [TEST No. 9 I OB/OG SILTY SAND WITH VARYING SILT SM DAHP WAS GROLJND WATER ENCOUNTERED? __ IF YES ~ WHAT DEPTHg.__ DEPTH TO WATER AFTER MONITORING: DATE OF MONITORING:, 7/8/13 A, HARALA SLOPE NO SITE PLAN SEE SITE PLAN GLAZING SIDEWALLS BOH @ 15.5' DEPTH TO DATE READING GROSS TIME NET TIME WATER NET DROF (HINUTES) (HINUTES) (INCHES) (INCHES) 1/22 TEST HOLE PRESOAKED PRIOR TO TESTING: i 5:26 .75" 2 5:56 30 1.25" .50" 3 3:57 .50" 4 4:27 50 1.00" ,50" 5 4:28 ,75" 6 4:58 50 1.25" .50" PERCOLATION PATE: 60 (MIN/INCH) PERC. HOLE DIA. 8" (INCHES) TEST RUN BETWEEN: 4 FT. and 5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO FEST. TEST PERFORMED BY ANDERSON ENGINEERING. l, MICHAEL E. ANDERSON CERTIFY THAT TH1S WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 5/12/15 MUMCIPAU TY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 015-282-53 1. GENERAL INFORMATION Complete legal description Woodhaven #3 Lot 8 Location (site address) 3850 Marcelle Circle Current property owner(s) Mailing address Real estate agent Chris Hester 2. TYPE OF DWELLING: Fx_1 Single Family (w/wo ADU) F -I Duplex R Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 Expiration Date Day phone Day phone 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well El Private Septic ED Water Storage El Holding Tank El Community Well 17 Community El Public Water System r_1 Public Sewer 0 Waiver request for: Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. Date: COSA Fee $ 55 0 Waiver Fee $ Date of Payment c�-2'3 �(7 Date of Payment Receipt Number. 6A 1 k S I Z If Receipt Number COSA # 0,5 C �1 1 � Ll-/ Waiver # Distan 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MCA COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Reliance on this report by another person is at their own risk. Pannone Engineering Services LLC highly recommends buyers hire their own engineer to evaluate this report. Name of Firm Pannone Engineering Services Phone (907) 745-8200 Address P.O. Box 1807 Palmer, AK 99645 Engineer's Printed Name Steven R. Pannone P.E. Date s��� OF Aq49 6. DSD SIGNATURE 4 • • . • • System #1 Approved for bedrooms Steven P. Pon nola2 System #2 Approved for bedrooms`��sl•. CE 8149 Disapproved�������� Conditional approval for bedrooms, with the following stipulations: n� 0 l I ea S S P-� 'i'i �wc(n e etas e'�%✓ �, V'yv►1 F V 512�12� By t/ Original Certificate Date: �eNfedss The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Septic System Advisory Well Flow Advisory COSA Checklist blue sheet p,UTY(OFr���i�/�i °1V-SiTE Nitrate Advisory WAT AND m Arsenic AdvisoryASrt_:y1!AT Other OGFAR �o JJJfJJ���SERVICEs��,,,\,� Legal Description: Woodhaven #3 L8 If more than 1 septic system on lot: COSA Checklist # 1 'of 1 Parcel ID: 015-282-53 Structure served by this system 1 A. WELL DATA ®❑ Well log is filed with Onsite (or attached) Well production at time of test 4.6+ gpm Date drilled 9/15/14 Water storage tank volume NA gallons Total depth 118 ft Well disinfected for coliform test? ❑ Yes R No Cased to 118 ft Q Coliform bacteria is Negative FE -1 Sanitary seal is functioning correctly Nitrate 2.6 mg/L ❑ Nitrate less than MRL (ND) Q Wires are properly protected Arsenic ug/L FE -1 Arsenic less than MRL (ND) Casing height (above ground) 18+ in. Collected by First Water Consulting Date of flow test for COSA 512021 Date of Sample 4/28/21 Static water level at beginning of test 43 ft. Comments Well Flow test performed by First Water Consulting Services B. TANK DATA C. LIFT STATION Age of tank(s) 4 years ❑ Required maintenance completed Tank type/material °"''`"'" Age of lift station years Measured operating fluid level in septic tank Lift station material ON Standpipes/foundation cleanout per record drawing Comments: Date of pumping 5/4/21 D. ABSORPTION FIELD DATA Shallow Trench Which system tested (date installed) 11 f2712017 COSA Adequacy test date 5/12/2021 MR ALL standpipes present per record drawing Results ❑✓ Pass For 4 bedrooms Total measured depth from grade 5/7.3 ft (max) Fluid depth prior to test 13/17 in Measured depth to pipe invert from grade 2.7/5.1 ft (min) Water added 600 gal ❑ N/A — pressurized field 18/19 . New depth In MR Monitor tubes go to bottom of effective. If not, state Elapsed time 60 min d depth into effective RE Code -required soil cover over field Final fluid depth 13/17 in ❑ System presoaked Absorption rate '600 gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) date of test) Gallons introduced gallons If yes, enter date Comments/Deficiencies:_ n Q_ - = . CV pVZ &-- r COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ✓� Yes Community Sewer Manhole/Cleanout > 100' ❑✓ Yes if No ft 7 Yes if No Neighboring Tank > 100' Yes if No ft Private Sewer/Septic Line > 25' F71 Yes if No Absorption Field on Lot > 100' Yes if No ft Holding Tank > 100' Yes if No Neighboring Absorption Fields > 100' Yes if No Animal Containment > 50' Yes if No ❑✓ Yes if No ft if No ft F. ENGINEER'S COMMENTS Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' Yes if No ft 0 Yes if No From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑✓ Yes if No ft Surface Water > 100' ft ft ft ft ft ®✓ Yes if No ft Property Line > 5' ✓� Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' El Yes if No ft Private Wells > 100' Yes if No Water Main > 10' ✓� Yes if No ft Community Wells > 200' ❑✓ Yes if No Water Service Line > 10' Q Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ED Yes if No ft If absorption field is under driveway comment below Property Line > 10' 0 Yes if No ft Wells on Adjacent Lots: Water Main > 10' ✓� Yes if No ft Private Wells > 100' Yes if No Water Service Line > 10' ❑✓ Yes if No ft Community Wells > 200' Yes if No Surface Water > 100' F/I Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION 1 certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. 2t® -ate COSA Checklist yellow sheet Steven R Pannone CE 814.9 k.ry ft ft ft 13021 Montego Circle, Anchorage, AI< 99516 907-350-9566 / firstwaterAK gi ail.com May 11, 2021 CHRISTOPHER & ASHLEY HESTER 3850 MARCELLE CIRCLE ANCHORAGE, AK 99516 VIA EMAIL RE: WOODHAVEN #3, .LOT 8 - ANCHORAGE, AIS ON-SITE WATER & WASTEWATER SYSTEMS INSPECTION REPORT Per your request, we have inspected the on-site water and wastewater systems of the above referenced 4 - bedroom property. This investigation was based on observations of the day in which the septic adequacy and well flow inspections were performed and according to available Municipality of Anchorage (MOA) record documents. This is to certify that as of the date of this letter, the subject on-site well appears to meet or exceed minimum state requirements pertaining to water production and quality coli, arsenic and nitrates (CAN). The 5 -bedroom Advantex septic system constructed in 2017 consists of a 2500 -gallon steel septic lift station tank with 2 AX -20 pods and 2 40' long trenches with 2' effective sewer rock depth. Based on the MOA record docs (soils, groundwater, design,) -- it appears the system was installed correctly. Upon our arrival to conduct the well flow and septic adequacy tests, it was observed that there was 22" and 28" of standing fluid in both of the fields monitoring tubes. The western trench had fluid 4" above the lateral. Based on these observations on the day we conducted our inspection, the fields are both currently saturated and will not meet MOA COSA standards. Audible dripping sounds were noted in both compartments when no one was inside the house. We were going to come back and remove the lids to investigate these sounds, but were given a stop work order. It was also noted that the post tank / pod cleanouts had heavy sludge and debris (looked like gravel) in them. There are several possible reasons why the fields may currently be in a saturated state. Although storm events, seasonal breakup / snowmelt, changes to drainage patterns and other events or actions may contribute to the functionality and state of a septic system, there should be no direct interactions of these types of events with the septic fields. Per our last conversation with your realtor, we were going to monitor the field over the next several weeks, verify if the recent snowmelt was the contributing factor of the fields being saturated and go from there to see if the system would meet MOA COSA standards. However, we have since been requested by Pannone Engineering Services, LLC to send them the water sample results which we took and can only assume that they are now completing the COSA process. If snowmelt / breakup is not the contributing factor of why we found the fields saturated at our inspection — our first thought was that the tank lids may be leaking and allowing groundwater intrusion and May 11, 2021 Woodhaven #3 L8 Pave 2 of? surcharging the field. If this is the case, we proposed having a contractor inspect the tank, conduct any necessary repairs, monitor fluid levels over a couple weeks and with dropping levels demonstrate to the MOA that the field will meet the COSA septic adequacy guidelines. If so, we believe the MOA will issue the COSA. However if this were not the case, we'd recommend conducting a testhole to verify groundwater and soils in preparation for a new field. Please let us know if you have any questions or how we can be of service in regards to these septic findings. Prior to commencing the well flow test, the static water level was measured at 43' from the top of casing. The wellhead consists of 6" steel casing extending 1.5+ above grade with a sanitary seal and conduit. The sanitary seal was jacked above the top of casing and needs to be addressed. The well produced 4.6+ gallons per minute (GPM) with a maximum drawdown of 22', which is well above minimum MOA water production requirements for a 5 -bedroom single-family residence. The well log shows a total depth of 1.18', a static water level of 40' and a water production of 10 GPM. A water sample was drawn and submitted to the lab for coli, arsenic and nitrate analysis (CAN). The results of this water analysis show that the water meets state and municipal safe drinking water standards (CAN). The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The absorption and flow rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristies, groundwater levels that may fluctuate during the year and the water- usage of the family being served by the system. The operational life of all well and septic systems is subject to these various and dynamic characteristics and are outside the control of the evaluator of the septic system. Therefore, we cannot give any estimate of how long a system will function satisfactory for current or future occupants or can we guarantee that no unseen encroachments, deficiencies or discrepancies exist. Based on this investigation, which was completed in compliance with state / municipal regulations and industry standards, I have certified the adequacy of the water well. If after review of these records you or any of the underwriters have any questions regarding the adequacy of these systems or the methods and/or procedures employed during our inspection or evaluation, please feel free to contact us at (907- 350-9566) or via ernail at FirstWaterAK@gmail.com. Respectfully, Curtis Huffman, P.E. Attachments: SGS Water Analysis FWCS Invoice i j i << 37 t i 1k1'(GIG Pannone Engineering ServiceS LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve(@panengak.corn May 24, 2021 Subject: Justification of Field Adequacy Permit Number: OSC211244 Legal Description: Woodhaven #3 Lot 8 I am writing in response to your comments concerning our Adequacy Test and COSA for this property. The field was tested by First Water Consulting on April 28, 201. Their report indicated that the field was saturated and operating in a surcharge manner. The report further states that there were "several possible reasons why the fields may currently be in a saturated state". PES conducted our adequacy test on May 12, 2021. The liquid levels were as noted on the COSA Checklist submitted to your department (13 inches at the front and 17 inches at the rear of the field). No audible drips were heard during our test. We did not observe any sludge in the monitor tubes. The entire system was inspected by Anchorage Tank as part of the Advantex maintenance program at the end of January, 2021. Their report indicated that the water levels were 17 inches at the front and 21 inches at the rear of the field, similar to the readings we found. The Anchorage Tank report did not indicate the presence of sludge in the field, nor dripping inside the tank. Some reason for the water levels observed by First water Consulting could be the excessive snow melt working its way through the soils. Anchorage had a near record snow fall this past winter. The Snow -tell sites in Anchorage bowl (Snow -Tell sites record the snow packs moisture content in an attempt to predict the anticipated run-off) recorded the highest ever level of moisture in the snow pack in late April in Snow -tell history in this year's snowpack. This combined with the rapid melt off has led to areas of Anchorage becoming saturated for a short duration giving the appearance of failed septic fields. The level of moisture running through.the soils are not unlike the effects of a dripping faucet on the drain field — the field becomes saturated with excessive moisture. Soils are only able to absorb so much water per day — thus causing the soils to become super saturated as water accumulates to be absorbed. The soils are silty sands, having a percolation rate ranging from 60 minutes per inch to 2.5 minutes per inch, thus indicating a highly variable soils. Further, Anchorage Tank did not note any deficiencies when reporting the current water levels of the monitor tubes or within the Advantex system. I believe the high levels of liquid in the drain field observed by First Water was due to the excessive moisture running through the soil. PES does not believe that this year's super saturation of surrounding soils will create a problem for the future owners. Please contact me if you have any questions. ......_._........................._...... P.0, Box 1307 ' .ilrnei; A,1\ �Gl Page 2 of 2 Steven R. Pannone, P.E. Uwner/]v|Engineer NA!ai||ng: F.D. Gox IO0I17,AnChora��,/\K9S51�-D2l7 Physica|��3ZE2s'K�anorAue,�nch�/a��,/\K,B95O1 T�|ephone:1. /9O7)27Z-82l8 FAX�(9O7\�7�'821l MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER. TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEM`' NT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this 6th Day of May of 2021 , by and between Monty tii Mvers , herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: I . Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as 3850 Marcel -le Circle, Anchorage AK 99516 located at (legal description) Woodhaven #3 L8 2. Maintenance, Repairs and Alterations. (Owner is required to read, understand and initial each section) W Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. W It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to 5600). W Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. M3 Owner acknowledges that regular- maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of 3 W Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. W Owner acknowledges that the tine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. M3 Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. W Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. M3 Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. �"I� Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The tenn of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 OWNER: Bsignature) Date: 5.6.2021 Monty yers (print name) STATE OF ALASKA ) ss. THIRD JUDICIAL DISTRICT ) The foregoing instrument was acknowledged before me this i,;` day of • . , 202A,by :Aii6& NOTARY PUBLIC FOR ALASKA 8 REM 0r ALASKA My Commission expires: De(,AAgw Pup= A-l{tia 0. Showalter IPfy Commission Expires Oct. 4, 2021 MUNICIPALITY: �gg � By: J 1 0-,- l " (signature) Date: (print name) Title: (rev. 05/18/2018) Page 3 of 3 Cl 5,'04:'2021 16:25 _686770 FLUS FA -GE 0? 395 659 MM19 M I E 0M®M MM M t c s` IS M R LNR 0M @ IRMO M 8 e o �dvanTeoe Field Maintenance I Report Anchors eTank Annual Insp 1ction 907-272-3543 Propnrty Ownerrrrscklnp d Oporntor Chris Hester Larry Betts Site Addroso _-- Cont�Ct PttOtN! 3350 Marcelle Girt e, Anchorage AK 99516 (907) 230-6055 AX Stet ID t; County ID E Pod r•' ATV VUL P 003 of Last Inspection AX -143351 0$P17'1047 1427707 427706 RTU136681 01/2.6/2021 Retrieve O&M info Daily flow Actin ratio _ Timer settings: Perform Field Samp Ing/Observatlons NTU (15 w NTUs) p I (6-9) DO (2-6) Odor t Simple pi ❑ Must ❑ Earthy Ir .3 Moldy Non -typical ❑ SUIfr '? ❑ Cab�baagoo ❑ Decay Oily film in PW [ ]yes I rNo Foam In tank [ 1Yea p Check Gontroi Pane Recirc Amps Discharge Amps 0 �I Audible and visual ala ns l OK Diaitone elan q , I�Na Inspect/Clean Pump System Inspect Clean Riser/Lid ..... . .... .......... a Splice Box ......... ........ . .. Float Cords ........ . . ........ 9f� Floats ............. ........ z Pump ..... . ...... ...........Z BlotuW Filter ...... ..........pi Biatube Pump Vault . .... _ ..... Recirculating Splittori :Iva....... Comments Signature Measure Sludge/Scum Sludae Srtrm 1 at Compartment Cumene _ Plmvious Current Previous 2nd Compartment CU�/ Previous Current Previous inspect/Glean AdvanTex Filter inspect Clean Odor. j Normal ❑ Pungent LsteraisfOditpr,!� Sicmzt; ✓Normal [Excessive Pod Bottom Bridging/Pondinone/Minor ❑Excessive I intake Von' Inspect/Clean Discharge Pump System Inspect inspect Clean Riser/LJd Floats] Splice Box Pump Y Float cords [ Inspect/Service Other System Components Inspect Clean Inspect Clean DlstnteGtion Equipment t �J�- j Dispersal Lateralsr/�Orifices (%� J Obsarvations �,Z �! d�YsAlh/ �/r_'J�-P,A Additional Services Rendered IN Cloanad textile sheets? ❑ Replaced UV items? Fj Replacod/Used other items? Parts Used: W = Warranty, is = Billable (✓ appropriate selection) W B item Number Description Final/Safety Inspection SV reinstalled Js bolted an i anifold reconnected; flush valves closed ontroi panel reactivated 5urnMalry/Recommend2tions Vystem performingl no further action needed ❑ Tank naeds pumping Call for service Other? Date Fax completed form to 1-866-0$4-7404 v") 1 8 9 10 >> G • •, Municipality of Anchorage a JAN 0 (2118ri. On Site Water and Wastewater Program �Ll I a " ivr (907) 343-7904CS E > .� • td g89 -'� Certificate of On-Site Systems Approval Parcel I.D. 015-282-53 Expiration Date: ` 4)r i a7 � o�D l �S 1. GENERAL INFORMATION Complete legal description Woodhaven #3 Lot 8 Location (site address) 3850 Marcelle Circle Current Property owner(s) Spinell Homes, INC Day phone Mailing address 1900 W. Northern Lights Blvd. #200 Anchorage, AK 99517 Real Estate Agent Day phone 2. TYPE OF DWELLING: Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 5 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Q Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received b • A L► ?AII � Date: l cW dl P COSA to be released to the engineer,unles - se equested by the engineer. COSA Fee $ Vq-SO Waiver Fee $ Date of Payment 1 tq I i? Date of Payment Receipt Number 39A Receipt Number COSA# d!J' rinOO& Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are)in compliance with all applicable Municipal and State codes, ordinances,and regulations in effect at the time of installation. In conducting an adequacy test,I attempt to provide a thorough,conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations.The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition,ground water levels that may fluctuate during the year,and the water usage of the family being served by the system.These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system,nor do they guarantee that there are no hidden defects or encroachments.Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 272-8218 Address P.O. Box 100217, Anchorage Ak. 99510 Engineer's Printed Name Steven R Pannone Date 1/8/2018 ..�`�OF C`s1 AMP' q 1 e .- vT 6. DSD SIGNATURE r System#1 Approved for 5 bedrooms .S/even R. Pannone: Ai System #2 Approved for bedrooms CE-8149 i Disapproved k` ss iFD�gp Conditional approval for bedrooms, with the following stipulations: -;.( OFAA/Cy z \NA R A‘yp 1pp*NT SER�`��5 By: 18"` e.A Original Certificate Date: c) 00 I The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet S • , c If more than 1 septic system is on the lot: COSA Checklist# 1 of 1 Structure served by this system 1 Certificate of On-Site Systems Approval Checklist Legal Description: Woodhaven #3 Lot 8 Parcel ID:015-282-53 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) Y Date completed 9/15/2014 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 1 18 ft. Cased to 118 ft. Casing height(above ground) 24 in. FROM WELL LOG AT INSPECTION Date of test 9/15/2014 NEW Static water level 40 ft NEW ft. NEW m. Well production 10 g.p.m. g.p.m. SAMPLE RESULTS: Coliform Neg colonies/100 mL Nitrate ND mg/L ND1/4/2018 Collected b PES Arsenic ug/L Date of sample: Y: B. SEPTIC/HOLDING TANK DATA Tank Type/Material S.T.E.P./SteelDate installed 11/17/2017 Tank size 2500 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout(Y/N) Y Depression over tank(Y/N) N High water alarm (Y/N) Y NEW Pumper N/A Date of pumping C. ABSORPTION FIELD DATA 11/22/2017 2.0 GPD/SF Shallow Trench Date installed Soil rating (g.p.d./ft2 or r ) System tyPo Length 40/40 ft. Width 5 ft. Gravel below pipe 2 ft. Total depth 4.75 ft. Eff. absorption area 571 ft2 Monitoring tube Y Depression over field N Date of adequacy test NEW Results (Pass/Fail) For 5 bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= 750+ g.p.d. N Any rejuvenation treatment(past 12 mo.) (Y/N &type) If yes, give date D. LIFT STATION Date installed 11/17/2017 Size ingallons 750 Y Manhole/Access (Y/N) "Pump on"level at 40 in. "Pump off' level at 36 in. High water alarm level at 45 in. Datum Botom Cycles tested New Y y Meets alarm &circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100+ On adjacent lots 100+ Absorption field on lot 100+ On adjacent lots 100+ Public sewer main 75+ Public sewer manhole/cleanout 100+ Sewer/septic service line 25+ Holding tank 100+ Animal containment areas 50+ Manure/animal excrete storage areas 100+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5+ Property line 5+ Absorption field 5+ Water main 10+ Water service line 10+ Surface water 100+ Wells on adjacent lots 100+ ABSORPTION FIELD ON LOT TO: Property line 10+ Building foundation 10+ Water main 10+ Water Service line 10+ Surface water 100+ Driveway, parking/vehicle storage 10+ Curtain drain 50+ Wells on adjacent lots 100+ F. COMMENTS G. ENGINEER'S CERTIFICATION -�,'OF 4 j' I certify that I have determined through field inspections and '�'�P' .'F i+ review of Municipal records that the above systems are in Ale *'49 THj\ *9 conformance with MOA COSA guidelines in effect on this date. Steven Pannone ��� / Engineer's Printed Name ' '•:Steven •. I onnone Date 1/26/2018 �+ y;• CE-8149i/ COSA canary sheet_2-6-15.doc 10' T. & E. ESMT. 15' GAS ESMT. 20' DRAINAGE ESMT. ,Q E. 231.A3 \ \ \ t N 7�5g'14 ck.C• OWE N 89°56'25"E 207.36' ,14„E 15100" 10' T. & E. ESNIT. N 78.56 1-- N �: 181 • WELL g I "' ,�• 0 IP: , `` O G !w 30' I •• �� ���G 3 0 oi t I SEPTIC SYSTEM 52.8' gi dg z - I S ce I 1r I •• ffi I • I58.7' • \\\���\``• N 89•56'58"E 308.88' \\\\\\ a `,ZO 13Vt. AS -BU I L T �� I HEREBY CERTIFY THAT I HAVE SURVEYED THE � \9� GASTALDI LAND PROPERTY DEPICTED ABOVE AND THAT NO `7 ENCROACHMENTS EXIST EXCEPT AS INDICATED. srlkltili, SURVEYING, LLC IT IS THE RESPONSIBILITY OF THE OWNER TO 4� OF �*A. ` ) JEFF A. GASTALDI, R.LS. DETERMINE THE EXISTENCE OF ANY EASEMENTS, �•�P ••""••A4.4 � By LC 2000 E. DOWUNG RD., SUITE 8 COVENANTS OR RESTRICTIONS WHICH DO NOT 0 "• • •s1-�• S ANCHORAGE. ALASKA 99507 APPEAR ON THE RECORDED SUBDIVISION PLAT. � �: 4971 # • PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA GRID DATE HEREON BE USED FOR CONSTRUCTION OR FOR ••• • A.•• • .••••r ESTABLISHING BOUNDARY OR FENCE UNES. Ste'; Iffy A. Gastaldi SN2735 11/29/2017 • J, •% ( / "Q IP ANCHORAGE RECORDING DISTRICT. ALASKA ♦ °�� ..I( z..1 S4� F.B. JOB NO. aA ••.....• a u►uca NOTE: NO CORNERS SET THIS DATE ��•`0fds3lonat L°��t 1 r r r��