Loading...
HomeMy WebLinkAboutTHUNDERBIRD FALLS LT 6Onsite File Thunderbird Falls Lot 6 PID# 051-411-07 MOA site visit (3/7/22), no signs that the well or septic system was unstalled under OSP151256. Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System Permit OSP151256 05141107000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Initial Permit Effective Dates: September 02, 2015 to Design Engineer: Seversen Gordon Subdivision: THUNDERBIRD FALLS Site LegalAddress: THUNDERBIRD FALLS LT 6 G:1764 Owner/Address: ROBISON MATTHEW 26550 KERRY LOOP CHUGIAK AK 995670000 September 01, 2016 Site Mailing Address: 26550 KERRY LOOP, Chugiak Lot Size in Sq Ft: 63903 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. CONSTRUCTION: Additional percolation test(s) shall be completed such that the entire proposed drainfield is within 30 feet of a percolation test. If design revisions are required, an approved change order shall be acquired priort to construction. Test results shall be submitted with the final inspection report1 Special Provisions: The drainfield mound shall be vegetated prior to approval of the final inspection report. Received By: "~-/ /~/ j ~ Issued By: ,,~ J/~//A ~;~J~-'~f I /tUNiCJPAL TY OF ANCHORAGE Cam ,munity Development Department Phone: 907-343-7904 Development Servfces Division ~ Fax': 907-343-7997 On-Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLiCATiON Prope~,own~(s) k~ ~o~ Dayphone (e~l)~O-~gOl Site address ~O [~ ~ ~ ~ A~ ~ Legal descdpSon (Sub'd_, Block & Lot) ~o~ b;¢~ ~L~ ~ Legs] descdp~on ~ownship, Range & Secdon) % ~ ~ ~ ~ ' ~ Lot Size __~_~¢~ Sq. Ft. Number of Bedrooms ___~ .... APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (~ all that apply) Absorption Field [] Initial ~. Single Family (SF) (w/wa ADU) Septic Tank [] Upgrade [] Duplex (D) Holding Tank [] Renewal [] Multiple Dwellings Privy [] (SF and/or D) Pdvate Well [] Water Storage [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance; l certify that the above information is correct. I further certify that this is in accordance with appliCable Munioipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. O PlS-I Waiver Fees: Date of Payment; Receipt Numbor; Waiver No. NARRATIVE DESCRIPTION ON-SITE WASTEWATER DISPOSAL SYSTEM Matthew Robison Thunderbird Falls Lot 6, T 16 N, R 1 W, Seward Meridian, Section 36 Probable impacts to adjacent properties should be Iow. The proposed gravel bed area is approximately 50 feet from the west lot line and 105 feet from the nearest well on Lot 3. The septic tank will be more than 100 feet from an on-site well location to be developed. Site drainage will be graded to ensure that runoff is directed away from the drain field area. Matthew Robison ! June 2015 S VERSEN · m n§ineerin§ MA'ITH EW ROBISON ON-SITE WASTEWATER SYSTEM VISIT REPORT IDate: June 3, 2015 Location: Peters Creek, AK Client: Matthew Robison Project: On-Site Wastewater System SE Project Number: ROBI-ROBI-001 SITE VISIT OBJECTIVES 1. Perform test hole percolation tests on May 27, 2015 and observe groundwater accumulation. PRIMARY CONTACTS DURING THE SITE VISIT 1. Mr. Matthew Robison, Property Owner SEVERSEN ENGINEERING 1. Mr. Gordon Seversen, P.E., Principal Engineer FINDINGS AND ACCOMPLISHMENTS Two test pits were observed, having previously been excavated and left exposed. Some sloughing had occurred at Test Pit TF6-1. I hand excavated to bedrock and observed no water at the bedrock interface. Observation seven days later revealed no change - no water had accumulated in the test pits. RECOMMENDATIONS AND/OR CONCLUSIONS After seven days of observance, no water was observed at the bedrock interface. It was concluded that it is possible a small amount of water may travel along the bedrock interface at some point in the year, but this water is not groundwater, only from subsurface infiltration. 10210 Ronald Place, Et~gle River, AK 99577 · 907-696-0157 Pen~ormed For: Legal Description: 7- 8- 9- 12- 14- 15- 16- 17- 18- 19- COMMENTS Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www,cL anchoraae,ak, us (907) 343-7904 Soils Log - Percolation Test Date Performed: Slope Township, Range, Section: 'TI~I.. ~.!1.~. ~,Jel,.. ,~.~ Site Plan £O3 & WAS GROUNDWATER ENCOUNTERED? S IF YES, ATWHAT DEPTH? -- L O Depth to Water After p Monitoring? ~'~¥ E Date: Reading Date Gross Time Net Time Depth to Water Net Drop PERCOLATION PATE ~-* (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~.~' FT AND ~.~' FT PERFORMED BY: ~.~¢.~¢,~tJ..~[r.t~:z,~_~t~ I ~:~d~CERTIFYTHATTHISTESTWAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 5- 6- 7- 8- 9- 10- 11- 12- 13- 15- 16- 17- 18- 19- 20- Performed For: Legal Description: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 vcww,ci.anchoraqe.ak.us (907) 343-7904 Soils Log - Percolation Test COMMENTS Date Performed: '~'/,~1 [1'~ Township, Range, Section: l"l&lk~ t ~2.{~Uj ~/~3 ~'~ Site Plan WAS GROUND WATER ENCOUNTERED? S IF YES, AT WHAT DEPTH? ~ L O Depth to Water After p Monitoring? ~ E ~.lzle~ Reading Date Gross Time Net Time Depth to Water Net Drop PERCOLATION RATE ~' (minutes/inch) PERC ROLE DIAMETER TEST RUN BETWEEN ~..0 FT AND ~oO FT PERFORMED BY: ~c.~av--~44. 'l~rt~l ~.~rf,,~ I ~:~t~ii~CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE, DATE: ~,f~/l~ / / / NOTES DESIGN CRITERIA LEGEND ANDABBREVIATIONS LOT6 / O 15 0 7.5 15 UND~'URBED 3O ~SITE PLAN C1.0 SHEET 1 OF 2 PLAN ELEVATION --4'~ NON PERFORAyEO PVC pipe · AS REO'D /- ~ENLARGED TRENCH SECTION ~ ~,Oo~N~ITORING TUBE SEWER CLEAN-OUT SCHEMATIC 1 5+8 TO 6.5' TO BEDROCK TRENCH SECTION ~.G~R.~VEL TRENCH PLAN CAP CAP SEINER CLEAN-OUT SIDE VIEW' NOTES TEST PIT 5 Ct.1 SHEET 2 OF 2 MUNICIPALITY OF ANCHORAGE Community Development Depar[ment '~-,~.,// Phone: 907~343-7904 On-Site Water & Wastewater Program ~ Fax: 907-343-7997 Septic System Owner-installer A.qreement A real estate property owner (Owner) may install their own septic system. The department may issue an approval for a homeowner to perform work on a conventional (not AVVWTS) on-site wastewater disposal system to serve that individual's owner'occupied, single-family or duplex home if the homeowner satisfies and agrees to the following requirements. The property owner and excavation equipment operator may perform work on no more than one owner installed project in a 12-month period. As owner of (legal description) 7-,~,~,/-¢/- 4¢, rJ -~ //~ ?o y ~ ~, following items are true and accurate. 1. My experienc(~ installing septic systems is as follows. I agree the 2. The name of the excavation equipment operator is. ,,/~¢-f4 ~ /'Zo ~,, ~- ~ 3. There will not be compensation for installation services rendered. 4. I will be actively involved with the septic system installation at all times. 5. The name of the inspecting engineer is I agree to discuss the following items with the inspecting engineer: a. Permit design criteria and specifications. b. Inspection requirements set forth in AMC 15.65.150. c. 2-hour minimum advance notice given to the On-site Water & Wastewater Program for all required municipal inspections. 7. 1 agree any changes make to the items listed above will require a new approval before performing work. 8. I agree to have the project-specific On-site Wastewater Disposal System Permit available at the construction site for the duration of all related work. Owner's printed name: Owner's signature~ Date: Septic System Owner Installer Ag reement_Feb2015.doc