Loading...
HomeMy WebLinkAboutSANDHILL LT 2On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP161130 Tax Code Number: 05052204000 Work Type: Septic Renewal Permit Effective Dates: June 21, 2016 to June 21, 2017 Design Engineer: RODNEY P KINNEY ASSOC INC Subdivision: SANDHILL Site Legal Address: SANDHILL LT 2G:0262 Owner/Address: RUPERT TODD J & TAMARA L 24821 HAMANN ROAD EAGLE RIVER AK 995779626 Site Mailing Address: 24821 HAMANN RD, Eagle River Lot Size in Sq Ft: Total Bedrooms: This permit is for the construction of: epartinent 68159 3 Y Disposal Field N Septic Tank N Holding Tank N Privy N Private Well N Water Storage 1. All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: The original ground level is to be verified during construction. Total depth of the trench is to be 6' max from original grade. Received Issued By: Municipality ®f Anchorage P.O. Box 196650 • 4700 Elmore Road Anchorage Alaska 99519-6650 a (907) 343-7904 a Fax (907) 343-7997 http:ilvvww.muni.org/Onsite Development Services Division On -Site Water and Wastewater Program * * * * VARIANCE/WAIVER REVIEW * * * * Waiver#: OSV161069 COSA#: _ Permit#: OSP161130 PID#: 050-522-04 Legal Description: Sand Hill Subdivision Lot 2 Engineer: Rodney P Kinney Applicant: Todd and Tamera Rupert Your request for a waiver of the required 50 feet horizontal separation from the absorption field to the excessive slope has been approved. The approved separation distance is 35.0 feet. This waiver approval applies to the existing and proposed absorption fields only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. ® Adjacent properties are not affected by this waiver. ............................................................................... Waiver is Granted: X Waiver is not Granted: Date: Z ( Approved by: Name of Reviewe ........................................................... .................. **** VARIANCEMAIVER REVIEW **** MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 050-522-04 Property owner(s) Todd and Tamera Rupert Day phone 907-694-8575 Mailing address 24821 Hamann Road, Eagle River Alaska 99577 Site address 24821 Hamann Road, Eagle River Alaska 99577 Legal description (Sub'd., Block & Lot) Sand Hill Subdivision, Lot 2 Legal description (Township, Range & Section) N/A Lot Size 68,159 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field ❑X Initial ❑ Single Family (SF) ADU) Septic Tank ElUpgrade F](w/wo ❑ (D) Holding Tank ❑ Renewal 121Duplex Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Cos. le (Si nature of roperty owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. OSPI IV 1130 Permit App_.}: Waiver Fees: Xa f,67 Date of Payment: 6/6/6 Receipt Number: 20/G5 7 Waiver No. /610169 (6) Rodney P. Kinney Associates, inc. eensunina Enalneers a surveyors May 24, 2016 Municipality of Anchorage Development Service Department On -Site Water and Wastewater Program 4700 Elmore Road Anchorage, AK 99519-6650 Attention: Mr. Jay Crewdson, PE Subject: Sand Hill, Lot 2 Absorption Field Replacement Dear Mr. Crewdson: The subject property is currently occupied by one residential structure consisting of a three bedroom single family home. The site plan shows the location of the structure in relation to the existing and proposed on- site sewer system. We are requesting your review and approval to construct a new absorption field to replace the existing failed absorption field. Attached are the following documents. 1. Site Plan and details, 2. MOA handout for construction requirements, 3. Soils log and percolations test, and 4. On-site Sewer/Well Permit Application for a Single Family Dwelling The adjacent properties consist of single family homes with on-site water and sewer systems. No wells exist within 100 feet of the proposed absorption field. The adjacent properties should not be affected by the location of the proposed improvements in regards to wells, septic systems, reserved space, and drainage. The existing and proposed septic system is located outside of any travel ways. The proposed absorption field is located on sloping ground at approximately 10%; however a cut slope greater than 25% is located 50 feet to the south of the new field. Please call (907) 694-2332 if you have any questions. Sincerely, RODNEY P. KINNEY ASSOCIATES, INC. y Riney P./Kinney, Jr., RE Project Engineer Enclosures 16515 Centerfiel0 Drive ■ Suite 101 ■ Eagle River, Alaska ■ 99577 907.694.2332 1 Fax 907.694.1807 0 www.roka.net (i) Rodney P. Kinney Associates, ince Consulting Engineers R surveyors June 16, 2016 Municipality of Anchorage Development Service Department On -Site Water and Wastewater Program 4700 Elmore Road Anchorage, AK 99519-6650 Attention: Deborah Wockenfuss Subject: Sand Hill, Lot 2 Absorption Field Replacement Comment Review Response Dear Ms. Wockenfuss: Please reference your review comments dated June 10, 2016 for the absorption field replacement for the subject property. Attached are revised drawings that provide additional information that address your comments. We have the following responses: 1. The soils log provided in our submittal was excavated to a depth of 12 feet below ground surface. The inspection report approved by MOA dated November 18, 1997 included a cross section detail of the trench that included an elevation of 82.1'. We are utilizing the same IBM; therefore, providing confirmation of no water or bedrock within 6 feet. The original existing ground will be confirmed if detected during construction and noted in the as-builts. 2. Slopes are shown in the site plan. 3. Southern trench is labeled as existing. 4. The west cleanout is repositioned to align with the trench perforated pipe. 5. The sweep direction for the cleanout just east of the beginning of the field is specified. A cut slope greater that 25% is located approximately 35 feet south of the existing trench. Over a period of 4 years, I have not observed any weeping or leachate surfacing from this slope. Also, the trench has recently failed and been completely surcharged with no signs of effluent daylighting from the road cutbank. We request a waiver of the 50 -foot setback requirement for the existing subsurface disposal field. Please call (907) 694-2332 if you have any questions. Sincerely, RODNEY P. KINNEY ASSOCIATES, INC. Rodney P. inney, Jr., P.E Project Engineer Enclosures 16515 Centerliel0 Drive I Suite 101 I Ea0le River, Alaska ■ 99577 907.694.2332 1 Fax 907.694.1807 ■ www.reka.net N I ST I� MT MONITORING TUBE —5— ,J w S m m '— M M I I I HAMANN SUBDIVISION \ \ 10' UTIL \\ ESMT y� `I I HAMANN SUBDIVISION 24 I I \ J � \ \ \ R040 / 15• LANDSCAPE BUFFER ESMT ESMT •y�/ \ \ �� — — _ / DRIVEWAY \ PROPOSED �y� / HOUSE / SEPTIC, SEE FIGURE 2 yM 4 1120' ,y'� j SAND HILL EXISTING / SUBDIVISION I SEPTIC `74g' I 1.5:1 ROADWAY \ \ l� ` \ 15' UTIL. CUT SLOPE � \ \ \ \ I ESMT 1s unL. ESMT ` _ \ to 8 \ \ \ \ \ I 7 LEGEND SANITARY SEWER CLEANOUT ST SEPTIC TANK CLEANOUT MT MONITORING TUBE —5— PROPOSED SEWER LINE S EXISTING SEWER LINE EXISTING WELL '— FLOWLINE TEST HOLE !9 TBM — TOP OF CMU = 100' DESIGN CRITERIA: GRAPHIC SCALE IN o so too 3 BDRM = 450 GPD SOILS = 1.2 GPD/SQ.FT. 450/1.2 = 375 SQ.FT. REQUIRED , inch = 100 teat 7.2't DEEP 4' EFFECTIVE 5' WIDE 38' LONG REDUCTION FACTOR = 0.50 ALL PORTIONS OF SYSTEM WITH LESS THAN 3.5' OF COVER REQUIRE INSULATION. CONSTRUCT WIDE TRENCH IN ACCORDANCE TO ATTACHED MOA HANDOUT FOR WIDE TRENCH REQUIREMENTS AND SPECIFICATIONS lowl 9Tu ..J.. .. ...... .... . o Ro ey P. Kinney Jr.: o-4 CE7955 q°% ..6/15/16 • .. • ,/ i P+'ofessiono'_.� A ABSORPTION FIELD REPLACEMENT SITE PLAN E Rodney P. KinneyAsseciai$ INC. SAND HILL, Cnnuultlno En.ln.nn . surveyor. LOT 2 6/15/2016 FIGURE 1 N GRAPHIC SCALE SAND HILL 20 ° 10 SUBDI VISION 2 1 inch = 20 feet I - I ti0(✓ CO#2 \ 1 y / h MT#2 \ \ 1 dF�P PERFORATED \ 1 N \ \ PIPE, IN \ TRENCH ONLY � I MT \ WIDE 1 STCO STCO \ SWING TIE TABLE ® BLDG. COR. S BLDG. COR. CO#1 M T#1 CO#2 M T#2 TO BE FILLED OUT AFTER CONSTRUCTION � \ \ O CO TRENCH .\ `.\ TH X80 \\ MT#1 I \ EOI_ MT \ - --f-- SEP CO \ \ EXISTING`. \� '`�/� SEE INSETFNISHED \ � TRENCH � / � GROUND i CO ORIGINAL GROUND LEVEL TO BE VERIFIED 1.5:1 ROADWAY DURING CONSTRUCTION CUT SLOPE 15' Um. MT#1=89.13' — ESIAT MT#2=89.13' \ �ROpF NO WATER FOUND AT RTY <�N 82.1' BOTTOM OF TEST NqM \F PIT (REFERENCE S&S SLOPE /� ENGINEERING INSPECTION 90 DRAWING, PAGE 2)--� MT 30' 24" EST. CO#1 13.13' CO#2=93.13' ROCK TRENCH DETAIL —NTS - 30' BEND INSTALL BULL CO PERFORATED RUN DIVERTER PIPE 2.5' s $ �0F7kN rV 0� 22.5' BEND * 9�. !�V r N' 4" SOLID PVC PIPE, s s e TYPICAL I � . 1.45' BEND O' BEND I�+0 '.Rod iey P. Kinney Jr..' m / �s �r CE7955Cop q°i/ 1tDtP�'.,6/15/16,..'_ "00 TO WEST) INSET A ,`�*. F' 016seiC2;4PI4I' ABSORPTION FIELD REPLACEMENT SEPTIC SYSTEM 0& Rodney RY lnneyhocim r$,1nrr. SAND HILL, LAYOUT SusmE.. Engineers a Surveyors LOT 2 6/15/2016 FIGURE 2 e +. Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST ROBERT C. COWAN (� c _ CE - 8801 PERFORMED FOR: IDfGL F- I G�"Y`M4'('8l, t�U1� DATE PERFORMED: t �{ LEGAL DESCRIPTION:__ t_7 8 1 ANjjgII.i. 5,tj Township, Range Section: PE JFq Ff) O R& 4,vi c- I SLI I I I SITE PLAN 4 73- 14- 15- 16- 17 314t51617 18 19 20 COMMENTS ! I S] L-rY, GJ>q,rl v �C WAS GROUND WATER FNCM IMTFGFN xj'f IF YES, AT WHAT DEPTH? Depth to Water After Monitoring? orcY Date: �.�-� 7 -Z8 -q1 S L D P E TREI Reading ate Gross Time Net Depth to Net Time Water Drop 1!25�3o I .1:2r". 30 I:?,; : 30 ,t 11 PERCOLATION RATE ' � (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN a' l FT AND 3 I/�" FT ..�GGrtIryV PERFORMED BY: EE�� pp aa''•aae�pp�� o�DD 4 CERTIFY THAT T}IIS TEST WAS PERFORMED IN ACCORDANCE WITH? SL1%F4�AN7P1Nt7N 8hW GUIDELINES IN EFFECT ON THIS DATE. DATE: $//'� (/ % % 72-OOB(Rev. 4/851 cvw lnnv. sing mVN ZJ Municipality of Anchorage Page of a DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 a Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number: 5W?,70a67 PID Number: 050 -5.2a -0V Name: '�'?T D � Wastewater System: New ❑Upgrade Address: 627ABSORPTION IVO" fi(s A/ L L V FIELD Phone: Oq�� �� No, of Bedrooms: ❑ Deep Trench Shallow Trench ❑ Bed []Mound ❑ Other LEGAL DESCRIPTION Soil Rating: / Total Depth from ori iyal grade: Lot: Block: SA bdiv Q !/o S / WX D GPD/Sq. Ft. to pipe bottom from original grade: Gravel depth beneath pipe (% %1� 2Depth Ft. Ft. Township: _ Range: Section: Fill added aboveori incl grade: Q 'rj a Gravel length: / /O i Ft. Fl. WELL: New ❑ Upgrade Gravel width: 5 / Number opines: Distance between lines: Classi anon (Private, A,B,C): Total Depth: r CasedgToo, r VATS J' 06 I Ft. Total absorption/aJreaM: Ft. Pipe material: FL .l Q Ft. 7W SO. Ft. % f����� i �O Driller: f / Date Drilled: Static Water L el: StAW,VA(J UjF'Q W a.S !D$-� /] Ft. Ins��tal��eer: h144,4E(1 CNSTQNC Tort Date Installed: /0/—/ 7—C/7 Yield:, (� pH (1 Pump Set at: h1V 4ov11 Casing Height Abov Ground: IF TANK Ft. SEPARATION DISTANCES Vseptic ❑ Holding ❑ S.T.E.P. To From Septic Tank Absorption Lift Holding Public/Private Man facturer:.� Capacity in gallons: Field Station Tank Sewer Lines ^ aO�AG� iAnllr Well lo I O0 k [J 2 Material: Number of Co apartments: Surfac Water 1 Do `r 100,1- LIFT STATION Lotze Line 16),4 Size in gallons: Manufacturer: Foundation 5 + I a t� "Pump on" level at: p off" level at: High water alarm at: Curtain Drain O /\ /V Pum Model Electrical Inspections performed by: Remarks: BENCH MARK Location and Description: -70-,p 0,0= CM P nrT —13 Assumed Elevation: 100Ft s F Inspections performed by: s & s ENGINEERING Dates: 1st �"'�"�` 17034 Eagle River Loop Road JIM 20 M-17-1117 r�" 2nd +' • °•= Eagle River, Alaska 99577 ? '} R d3ERT C. COWAN f C 4y�t CE - 8601 Department of HeAland man Services approval Reviewed and approved by Date: % cvw lnnv. sing mVN ZJ PsmaT N0. SW970267 PAGE 2 OF 2 Municipalit of Achora e DEPARTMENT OF HEAnTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.D. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR/WELL INSPECTION REPORT I&GAT LOT 2, SANDHILL SUBDIVISION P.I.D. NO. 050-522-04 TRENCH ALT. SITE A 3 eFw tioSFM a� DBL 1-,\ 5!1 F( \ DBL2 \ST2 \ �\ CO2�� \\\ \\ \ NAr NN v \\.MT1 � co A U�rLrTY NEW 1000 GAL. 41x{ AS�+IIE 4 SEPTIC TANK \ � �1�JA ,. N J1 � 4 oT, 440 N STI STgFINAL GRADE 99.3' � MT \ \\� /// C01 = 96.3' SCALE 1" = 4 ' L,_�CO2 = 96.1' 100• WELL 94.6'1 1 1000 GAL SEPTIC JN��94.4 TANK MT1 = 88.1 MT2 = 88.1 C01 = 92.2 CO2 = 92.1 A NO WATER FOUND 82.1' B.O.H. �_j ..............., ROBERT C. COWAN �0, 0,A\ CE .8801 S Y f.. V` I• Docbco dee SULLIVAN WATER WELLS P.O. BOX 670272, CHUGIAK, ALASKA 99567 • TELEPHONE 688-2769 OWNER OF LAND "TQ,%)n r IH P'-%00'7 UI�/'�e~ ADDRESS I&D 30 I aaEJ fr jus G %�— LEGAL DESCRIPTION-TAeJO MLt_ A aT &. s� PERMIT NUMBER? *Oe2 6 Date of dLA12- TAX TAX INDENTIFICATION NUMBER QS'0 Sa o2b Is well located at approved permit location? Z) -Yes ❑ No Method of Drilling: J�J air rotary ❑ cable tool Depth of well: S"00 Casing Type„X4tLWall Thickness d5o'b _inches Diameter 1 • inches, depth /3.' Lf feet Liner Type: "s)6A E Casing Stickup Above Ground: oZ feet Static Water Level (from ground level): 171 � feet Pumping level: feet after hrs. pumping gpm Recover Rate: 4� 6 Method of Testing: Well Intake Opening Type: ❑ Open End 416�pen Hole ❑ Screened, Start feet Stopped feet [1 Perforations Start n feet Stopped feet Grout Type, -roorL 4#0' volume 0172 40S Depth: from 0 feet, to feet Pump Intake Depth: feet Pump Size hp Brand Name Well Disinfected Upon Completion? bXs`�Q No Method of Disinfection: Comments:641ct/ ��/k f � ,041-a i . 0 I D7 6 4 71 eA siN6 S rfctG,'P 00IF'et jA-0i n1 fig i r Ccrf�' 694.4; G E6'#J "'nC't 6A*&y Drilter's Name Z. 0 Q MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW970267 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:BEST KEN OWNER ADDRESS:18030 HIDDEN FALLS EAGLE RIVER, AK 99577 PARCEL ID:05052204 LEGAL DESCRIPTION: SANDHILL LT 2 PAGE 1 OF 1 DATE ISSUED: 8/21/97 EXPIRATION DATE: 8/21/98 LOT SIZE: 70800 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: I. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) . (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: MAINTAIN 50 FEET SEPARATION DISTANCE TO SLOPE GREATER THAN 25%, PER AMC 15.654c)(1. RECEIVED BY: 4'",- DATE &-/'2 '411 ISSUED BY: DATE: of g s& July 31, 1997 ROBERT C. COWAN, P.E. CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 HEALTHAUTHORITY APPROVALS MUNICIPALITY OF ANCHORAGE Department of Health and Human Services SEWER&WATER P.O. Box 196650 MAIN EXTENSIONS Anchorage, AK. 99519 REFERENCE: Lot 2, Sandhill Subdivision SEWER $ WATER INSPECTION Request you issue a permit to drill a well and install a septic system to serve the Proposed three bedroom house on the referenced property. ENGINEERING STUDIES AND REPORTS A test hole was excavated and percolation test performed. The approximate location the of test hole is located on the attached site plan. WELL INSPECTION & FLOW TEST At the time of excavation no groundwater was encountered and after seven day groundwater monitoring, the monitoring tube was found to be dry. This property has enough area for a future septic upgrade which can be seen on the SITE PLANS attached site plan, We do not anticipate any adverse effects on neighboring wells, septic systems or drainage ROAD DESIGN patterns by the installation of the proposed septic system. There are no points of contamination within the proposed well radius which can be the attached site plan. seen on SOILTEST If you require additional information, please contact us. Sincerely, PERCOLATION TEST Robert C. Cowan, P.E. STRUCTURAL$ MECHANICAL RCC/jm INSPECTIONS Enclosure ON SITE WASTEWATER DISPOSALSYSTEM DESIGN 17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577 fid' SCALE I_ SITF PI AN I DESIGN C rg-/ U)W WU-p �xro �r�TIrTl oFW ro � O� w Ov O c o cl cn � o ro c" z oy � / A (A o� / r'J :-i Ti m / qZ* o / 33' BLM SECTION LINE EASEMENT / O i U) v m ° rr 04 0 �\ / / Z / O f otio-' zC) O An A:��Z� O ON�m-'Com 0:D::C y IZA / o C7m -oo ai�0<mm DKAorizo / i O ZO gg mz>m cs> hi G') d r rN 0 � .. o t£lx c O vo 0,n / �ro o —1 Ami oX X-20 z r �w O�> im ZN I yr �mz _000 ■■ ?cam--+Zm Ste• s+ rn 10 orz$Uil -{ r- Z7i.'O - Q m ti " o4"auczi -"I< In OD z m \ A n () m 3 <DQ '^cNm O i•b\� z s, m e Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 •'L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST PERFORMED FOR: I(9 f- 1 (�'1MCL'i�l, ��nQ�'T DATE PERF( LEGAL DESCRIPTION: 1-2 0 If SAntbW)L.z..• Vp Township, Range, Section: r DEPTH SLOPE SITE PLAN SFkET) O /d G Anrl C- -S I I I I I 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 D' L zo COMMENTS C-/11 is, 0. ti. S) yr y, 8�7 u� y WAS GROUND WATER o ENCOUNTERED? S IF YES, AT WHAT L DEPTH? P E Depth to Water After Monitoring)2� Date: 7—ZB-g`f Reading ate I Gross 1 Time Net Time Depth to Water Net Drop Z C2 -5t30 YVIAYL 4 t tl :26:30 n 4 "W) ! T, 113'30 et r ll I it i, ,�yy tl PERCOLATION RATE •T' 1) (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN 4'12- FT AND S //.:L FT PERFORMED BY: pp17034pp"ogleeeRiye44_��L�p_pp_44_ Road N _d4 ���j/1 �-�liTtf'I�,r CERTIFY THAT T IS TEST WAS PERFORMED IN ACCORDANCE WITH7SL`NR I t AN�1G1L7NT9AM GUIDELINES IN EFFECT ON THIS DATE. DATE: _ o �� ° % 7 72-008 (Rev. 4/85) HEALTHAUTHORITY APPROVALS SEWER & WATER MAIN EXTENSIONS SEWER&WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOILTEST PERCOLATION TEST STRUCTURAL& MECHANICAL INSPECTIONS ONSITE WASTEWATER DISPOSALSYSTEM DESIGN mil ROPIrPT r rrvAiAKI 0= CIVIL ENGINEERS (907) 694-2979 ON-SITE WASTEWATER DISPOSAL SYSTEM FAX (907) 694-1211 CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS REFERENCE: Lot 2, Sandhill Subdivision July 31, 1997 GENERAL: The scope of this project includes the installation of a 1000 gallon septic tank and a five foot wide drainfield to serve the proposed three bedroom residence for the referenced property. 2. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The contractor shall be responsible for obtaining any necessary underground utility locates. 4. TJnless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil. settling. On all Ieachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. 9EP'I'IC TANK INS'T'ALLATION: 1. A septic. tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleatrouts for pumping access. 2. The septic tank shalt be sufficiently bedded to prevent settling or shifting of the tank. 3. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade, 17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577 Page Two Lot 2, Sandhill Subdivision July 31, 1997 4. Septic tanks installed with less than 4 ft. of cover shall be insulated. 5. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. 6. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (ruffed -up) before gravel (sewer rock) placement. 2. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. 3. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. 4. Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. 5. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. MINIMUM MATERIAL SPECIFICATIONS: Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. Page Three Lot 2, Sandhill Subdivision July 31, 1997 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: 'Tyre of Pip Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam IB or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. 6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. 7. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements, which ever applies. INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 2. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. 3. The final inspection is to occur upon final grading of the property. Page Four Lot 2, Sandhill Subdivision July 31, 1997 Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre - construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/OWNER