Loading...
HomeMy WebLinkAboutWAGNER LT 1Onsite File Wagner Lot 1 PID# 017-092-88 Formerly Wagner Tr 2 Municipality of Anchorage On -Site Water and Wastewater Program • (907) 343-7904 Page I of 3 OWSITE WASTEWATER INSPECTION REPORT Permit Number: OSP151054 PID Number. 017-092-33 Dwelling: M Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: M New ❑ Upgrade Name: Erik Hjelm ABSORPTION FIELD M Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound `Mess 14910 Wildien Drive Anchorage, AK 99516 171 other Phone Number of Bedrooms Soil Rating Total depth from original grade 947-1110 1 4 .45 GPD/SF 12.2 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4.2 Ft Gravel depth beneath pipe 8.0 Ft Subdivision - Block Lot Wagner Tract 2 Fill added above original grade Ft. 0-1 Gravel length 84 Ft. Township Range Section Gravel width 3 Ft Beds: Number of tines Distance between lines I Ft EPARA71ON DISTANCES TO Septic Absorption LIR Station Holding SewerTotal absorption area Number of trenches Dist between trenches I From Tank Feld Tank Line 1,3W& Fe TWO >1t/—&V Ft. Well >100' >100' >100' >75' >25' TANK NSeptic ❑S.T.E.P. Holding r_] Other Manufacturer Anchorage Tank Capacity 1 1,250 Gal. Surface Water >100' >100' NA NA Material Number of compartments Lot Line >5' >10' NA NANA Steel Two Foundation >5' >10' NA NA ILIFT STATION Manufacturer capacity curtain Drain None Noted Gel. Remarks Slope fronting absorption trench Pump on level at in. Pump off level at in. High water alarm at in. flattened to <25% for 50'. Punip make and model Electrical Inspections performed by Installer PIPE MATERIAL House to tank D3034 d amfield D3034 Red Dog Excavating Draintiela F810 corMT Inspector W. Roberts BENCH MARK (Assumed elevation)100.0 it l"sp1� 5/8/15 5/11/15 Location and description 2- dates:3m 0 House Lower Level Finished Floor. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp ♦s��h►�gL JF41 Conditional Approval: Date 'PN `tifQ�i �.�49thLA•� �. .p. WHAE.xE. ANxxxx. .. MICHAEL E. ANDERSON No. CE -4381 ��2= Appr6gd Date 2 -LZ- '+�; ;�•• Inspection Report 9-1-12.doc Permit Number: OSP151064 49th Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 TRACT 1 S 89'57'18'E 367.14' MICHAEL E. ANDERSON 0' UTILITY EASEMENT UNSUBDIVIDED Garage TRACT 2 WAGNER 101,331 s.f. Advantex Treatment System with 20' Long x 3' Wide x 8' Effective Depth Absorption Trench. 2 GPD/SF Application Rate. Page 2 of 3 PID No.: 017-092-33 B RIGHT OF WAY EASEMENT PLAN AS BUILT SCALE 1' = 50' LEGENn Mr — Monitor Tube FOO — Foundation Clean Out TH — Test Hole CO — Clean Out FSV — now Splitter Valve GRAVELW I— QAIVEWAY;. v . . m z m <j Z/" rn r t C4 v a CB Hz N MICHAEL E. ANDERSON 0' UTILITY EASEMENT UNSUBDIVIDED Garage TRACT 2 WAGNER 101,331 s.f. Advantex Treatment System with 20' Long x 3' Wide x 8' Effective Depth Absorption Trench. 2 GPD/SF Application Rate. Page 2 of 3 PID No.: 017-092-33 B RIGHT OF WAY EASEMENT PLAN AS BUILT SCALE 1' = 50' LEGENn Mr — Monitor Tube FOO — Foundation Clean Out TH — Test Hole CO — Clean Out FSV — now Splitter Valve Page 3 of 3 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP151054 PID No. 017-092-33 Co / N UU y 1,250 Gallon Septic Tank p 99.2 98.0 N V p 99.6 n 95.4 11 Drainfield Rods 95.4 87.4 81.0 43' (Trench Length) No Groundwater �J WEST TRENCH 99.3 98.0 Finished Greco 96.3 4II Drainfield Rods 87.3 81.0 43' (Trench Length) No Groundwater j EAST TRENCH PROFILE AS -BUILT No Scale p 99.4 n February 18, 2016 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Tract 2, Wagner Subdivision Waiver Request Absorption Trench Sidewall to Absorption Trench Sidewall Dear Onsite Services Engineer: The new absorption trenches constructed on the subject lot were placed less than 16' apart because of problems controlling the alignment during excavation. The sidewall at the south end of the westerly trench is only 14.3' from the sidewall of the easterly trench. It then transitions to 16' at 17' to the north. Only a short segment of the trench is less than 16'. We therefore request a waiver be issued allowing the trenches to remain in their existing locations. The effluent in the trenches will be absorbed downward into the accepting soils and very little migration in an easterly or westerly direction is anticipated. Sincerely, y4'z_.J' 'f� a'l' Michael E. Anderson, P.E. ii ••'• 49th (�V •••••••'-%} MICHAEL E. ANDERSON NO. CE -4381 , On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road; PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP151054 Tax Code Number: 01709233000 Work Type: Septic Initial Permit Effective Dates: April 02, 2015 to April 01, 2016 Design Engineer: ANDERSON ENGINEERING Subdivision: WAGNER Site Legal Address: WAGNER TR 2 G:3038 Owner/Address: HJELM ERIK 14910 WILDIEN DRIVE ANCHORAGE AK 995163967 Site Mailing Address: 14551 GOLDEN VIEW DR, Anchorage This permit is for the construction of: Lot Size in Sq Ft: 101335 Total Bedrooms: 4 Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued % Municipality of A P.O. Box 196650 0 4700 Anchorage Alaska: 99519-6650 • (907) 343-79 chorage went s 0.epai Imore Road4• Fax (907) 343-7997 `tment MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907=343-7904 Development Services Division Fax: 907-343-79911 TAL On -Site Water & Wastewater Program vik 2 2015 ON-SITE SEWERIWELL PERMIT APPLICATION Parcel I.D. 017-092-33 Property owner(s) Eric Hjelm Day phone 947-1110 Mailing address 14910 Wildien Drive Anchorage, AK 99516 Site address 14551 Golden View Drive Anchorage, AK 99516 Legal description (Sub'd., Block & Lot) Wagner, Tract -4a Legal description (Township, Range & Section) Lot Size 101,335 Sq. Ft. Number of Bedrooms Four APPLICATION IS FOR: (® all that apply) Absorption Field Septic Tank 19 Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ IN APPLICATION IS AN: TYPE OF DWELLING: Initial Single Family (SF) Q (w/wo ADU) Upgrade ❑ Duplex (D) ❑ Renewal ❑ Multiple Dwellings ❑ (SF and/or D) Absorption Trench to Slope -Tv�.rnf'i 4rrTrLt�i �-dertifv that the above information is corr M I further certify that this is in (Signature of property owner or authorized agent) Dis tance: 35738' ty, 3 cordance with Permit/Rush Fees: '569- Waiver Fees: A/S ` Date of Payment:S� f / $ Date of Payment: 31a q/ 17 Receipt Number: Permit No. tis P/IT/(1151 Permit App_":. :_'.,:c_ Receipt Number: Waiver No. OSV 16-1009- Permit u (UU% ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX March 23, 2015 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 Elmore Road Anchorage, AK 99519-6650 Subject: Tract 2, Wagner Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Tract 2, Wagner Subdivision intends to construct a new four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to accommodate the home. A well is currently in place on the lot. The attached Site Plan and backup documentation identify the location and configuration of the existing well and proposed septic system along with the alternate site. Also identified on the plans are the existing wells in the area and septic systems on surrounding lots. No conflicts exist between the proposed septic system and well or septic systems and wells on adjacent lots. Drainage arrows and ground surface contours are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot in the area of the absorption trenches and alternate site indicate silty sand with gravel (SM/GM). The percolation rate of the soil at the existing test hole was determined to be 30-40 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. An application rate of .45 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250 -gallon septic tank and 2-42' long by 3' wide by 8' effective depth absorption trenches to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 3' below the surface and the total depth will be 11'. A flow splitter valve will be placed to insure even flow to each trench. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the septic system slopes to the west at a shallow grade with some cross sloping from the east. The new trenches will be constructed parallel with the contours of the slope as much as possible in conformance Tract 2, Wagner Subdivision March 23, 2015 Page Two with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sinc/erely,, ar Q Michael E. Anderson, P.E. Attachments MICHAEL E. ANDERSON No. CE -4381 - TOP OF ............ . 1 FOU 197 4A' 5/8"x30" REBAR LEGEND MT — Monitor Tube FCO — Foundation Clean Out TH — Test Hole CO — Clean Out FSV — Flow Splitter Valve Contour Interval — 2' : tL UNSUBDIVIDED SITE PLAN SCALE 1' = 50' 0 0 CA 0 t'? N V p 0 0 PARCEL 18 49th • MICHAEL E. ANDERSON No, CE -438811 ti TRACT 2, WAGNER SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS Four Bedroom Home Deep Trench System Perc. Rate: 31-60 Min./Inch 1,250 Gallon Septic Tank Application Rate: .45 GPD/SF 8' Drainfield Rock 4 Bedrooms X 150 GPD/.45 GPD/SF (Application Rate) = 1,333.3 SF Absorption Area 1,333.3 SF/16SF/LF = 83.3 LF Trench Length THEREFORE: Construct 2-42' Long x 3' Wide x 8' Effective Depth Absorption Trench at the Location Shown. Flow Line Elevation in Trenches to be 3' Below Original Ground Surface. Total Depth to be 11' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Maintain 100' Separation from Wells in the Area. Natural Backfill Geotextile Fabric 6" O 4" Perforated PVC (Holes Down) M 3' Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams. MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: WAGNER TR -2 PERFORMEDFOR: ERIC HELM/MAX MEDEMA DATE: 7/15/I4 PROJECT No.: PARCEL ID#: TECHNICIAN: JB DEPTH TEST HOLE 1 (feet) 1 OB/OG 2 3 4 5 SM/GM 6 7 8 9 SLOPE WAS GROUND WATER ENCOUNTERED? No 10 IFYES@ WHATDEPTH? DEPTH OF WATER AFTER MONITORING: NONE L I DATE OF MONITORING: $/1/2014 14- 15- 16- 17-- 4151617 BOH @ IT 18 49th E. ANDERSON DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 7/15 1 1:20 3.125 2 1:50 30 4.00" ,875" 3 1:51 3.25" 4 2:21 30 4.00" .75't 5 2:22 3.125' 6 2:52 30 3.875" .75" PERCOLATION RATE:: 40 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4.5 FT. and 5.5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 3/20/15 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 �• 49th , !V SOILS LOG - PERCOLATION TEST E. ANDERSON LEGAL DESCRIPTION: WAGNER TR -2 PERFORMED FOR: MAX MEDEMA DATE: 7/15/14 PROJECT No.: PARCEL ID#: TECHNICIAN: JB DEPTH TEST HOLE 2 (feet) 1111111111111 OB/OG 2 3 4 5 6 SM/GM 7 8 9 10 11 1 17 BOH @ 17' 18 19 SLOPE WAS GROUND WATER ENCOUNTERED? No IF YES @ WH DATE DEPTH OF WATER AFTER MOM GROSS TIME (MINUTES) DATE OF MO DEPTH (INCHES) To WATER AT DEPTH? O TORING: NONE NITORING: 8/1/14 - DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH (INCHES) To WATER NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 7/15 1 1:25 5.25^ 2 1:55 30 4.25^ 1.0011 3 1:56 5.00° 4 2:26 30 4.125" .875" 5 2:27 5.25" 6 2:57 30 4.375" .87511 PERCOLATION RATE:34.3 (MIN/INCH) PERC. HOLE DIA. 9 (INCHES) TEST RUN BETWEEN: 4 FT. and 5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 3/20/15 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX March 23, 2015 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Tract 2, Wagner Subdivision Absorption Trench to Slaorth Wi Dear Onsite Services Engineer: The ground surface slopes on Trdivision exceed 25% toward the west property line. The proposedstem is approximately 38' from a break in grade greater than 25%.he alternate site is 35' from the same break in grade. We are therefore applying for a waiver allowing placement of the absorption trench at this location. The imaginary 25% slope when extended downward from 2' above the distribution line does not daylight. We therefore recommend the waiver be issued allowing the trench system and alternate site to be placed at the location shown on the Site Plan. Sincerely, " a-., Michael E. Anderson, P.E. L43 MICHAEL E. ANDERSON No. CE -4381 745' 740' 735' 730' 725' 37' 720' 715' Exist) Grou d 710' 25% 25% 705' 700' 0 5' 10' 15' 20' 25' 30' 35' 40' 45' 50' 55' 60' 65 75 80' 85' 90' 95' ..AS..��1 , 115' AV or T WAGNER SUBDIVISION i ... .......... TRACT 2 00 MICHAEL E. ANDERSON %,�� -4381 SLOPE ASSESSMENT SLOPE ,,1�fti\a�aav�''• MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 01 7-092- S16 Expiration Date: 7- 1 ,zoz 2- 1. GENERAL INFORMATION Complete legal description Wagner L_ca- _I Location (Site address) 14551 Golden View Drive, Anchorage, AK 99516 Current property owner(s) Erik Helm Day phone (907)947-1110 Mailing address Real estate agent 14551 Golden View Drive, Anchorage, AK 99516 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 Day phone 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ❑■ Private Septic Q Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. Date: COSA Fee $ -6-5 () I Waiver Fee $ _ Date of Payment 3/21 l A0 a s Date of Payment Receipt Number 0 C) � b Receipt Number COSA # SSG 22 g Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering (M.J.) Phone (907) 522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage, AK 99503 Engineer's Printed Name Benjamin Schiller, P.E. Date 3/28/2022 A��`�l ', �t TH 6. DSD SIGNATURE % ,• • :: JJ 1 �S- System #1 Approved for 4' bedrooms Ir Benjamjrt�5chiller System #2 Approved for bedrooms ��F��st •. CE 12o 2 . •'������/ Disapproved 11 ROFESSI Conditional approval for bedrooms, with the following stipulations: `\1�\�,( OF AkCy By: Original Certificate Date: - Zr�� The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet a� W Q)OGh TS By: Original Certificate Date: - Zr�� The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet COSA Checklist Legal Description: Wagner Lot 1 Parcel ID: 017-092-33 If more than 1 septic system on lot: COSA Checklist # of Structure served by this system A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled Unknown Total depth '75* ft Cased to >40* ft 0 Sanitary seal is functioning correctly 9 Wires are properly protected Casing height (above ground) >18 in. Date of flow test for COSA 2/22/2022 Static water level at beginning of test 41.6 ft Comments *Measurements taken from 2016 COSA B. TANK DATA Age of tank(s) 6 years Tank type/material Septic/Steel Measured operating fluid level in septic tank 49 0 Standpipes/foundation cleanout per record drawing Date of pumping 3/21/22 Isaac's Pumping Service D. ABSORPTION FIELD DATA Deep Trench Which system tested (date installed) 5/8/2015 Q ALL standpipes present per record drawing Total measured depth from grade 3.2/4.9 ft (max) 2/13.2 Measured depth to pipe invert from grade 11.ft (min) ❑ N/A — pressurized field FC Monitor tubes go to bottom of effective. If not, state depth into effective Well production at time of test 1.0 gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ No 9 Coliform bacteria is Negative Nitrate 0.277 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑® Arsenic less than MRL (ND) Collected by Forge Engineering Date of Sample 3/15/2022 STATION ❑ Requl aintenance completed Age of lift station years Lift station material Comments: Adequacy test date 2/22/2022 Results ZPass For 4 bedrooms Fluid depth prior to test 18/21" in Water added 750 gal New depth 28/29" in Elapsed time 1440 min 11/9* 9 Code -required soil cover over field Final fluid depth in Absorption rate >600 d Q System presoaked p 9p (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) date of test) Gallons introduced 2000 gallons If yes, enter date Comments/Deficiencies: "Fluid measurements post presoak. Measurements listed for West/East trench. COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' E✓ Yes Community Sewer Manhole/Cleanout > 100' ft f✓ Yes if No ft M Yes if No ft Neighboring Tank > 100' Q Yes if No ft Private Sewer/Septic Line > 25' Q✓ Yes if No ft Absorption Field on Lot > 100' Q Yes if No ft Holding Tank > 100' Yes if No ft Neighboring Absorption Fields > 100' if No ft Animal Containment > 50' Yes if No ft Q Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' Q✓ Yes if No ft 0✓ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' R Yes if No ft Surface Water > 100' M Yes if No ft Property Line > 5' Q Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' M✓ Yes if No ft Private Wells > 100' Yes if No ft Water Main > 10' ... ✓I Yes if No ft Community Wells > 200' Q✓ Yes if No ft Water Service Line > 10' Q Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' E✓ Yes if No ft If absorption field is under driveway comment below Property Line > 10' Q Yes if No ft Wells on Adjacent Lots: Water Main > 10'✓Q Yes if No ft Private Wells > 100' 0 Yes if No ft Water Service Line > 10' Q✓ Yes if No ft Community Wells > 200' Yes if No ft Surface Water > 100'✓❑ Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION / certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet TWO. *: 49 TM ���IenjaIchiller®` Alt* •. CE 12592 .`%�'� �J'l ' . • 3/28/22 • �� ��k®�, PROFESSO0 C) .:. 0C) 0.03*D -' m w o 3 to �om Dm o m S -0 O3nm330 rt ov "t Q • oy t w Sm -+ w m Q N w Q< o m m 3 0.0 c 0 "Z3 D -,, w��.moz'< �m �o tno � �o a" 077 n -t'v S _tII Ui o om=mvm- 3w0� ptbmNyC7S M n G _s, �"2000 S w C7 0 0 m " o w =o l< n oaDzc 00 -oi� -0G 3�'o`�t 3 Q�o107 o n. 3 -4 CL vm to m m rto a SM n 3 0 CD � 3 0* rt ay �0 3 0 w rt 3' '0S N 00 w 's °• S tD A t m_ -�- 3 m �X 1'• _ _ 0 otba 0.- 0 D. 3 3 y Cx d C m �O OQ, -3i 'Q o "> N-a 0 w o G O n to m .+ o 7 Q m 3 QS. D C tnm <m�a ~ 3 CO N + 0�C -03 SS CD 0 K _0 -3i• y aO 3 rt n S m n a m 0 D O w n D m 0 0 tO m CA q t7 0 W 0 L4 00 11C d" ® MIl>tnicipaRIltr of Anchorage On -Site Water and Wastewater Program 2 (907)343-7904 Certificate of ®n -Site Systems Approval Parcel I.D. 017-092-33 Expiration Date: B. GENERAL INFORMATION Complete legal description Wagner, Tract 2 Location (site address) 14551 Golden View Drive Anchorage, AK 99516 Current Property owner(s) Erik Hjelm Day phone 947-1110 Mailing address 14910 Wildien Drive Anchorage, AK 99516 Real Estate Agent Day phone 2. TYPE OF DWELLING: M Single Family (wlwo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: i ur 4. TYPE of WATER SUPPLY: TYPE of WASTEWATER DISPOSAL: Individual Well 0 Individual X Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer M WaiverAlariance request Recelved by: 1 ZL / 1,; M //)/1Q/ Date: a a,Zlk COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ (01.9 D / Date of Payment Receipt Number C)5-7 t `7 (55) COSA# 05CG /0;-[ Waiver Fee $ Date of Payment Receipt Number Waiver # S. STATEMENT Or INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Sox 240773 Anchorage, AIL 99524 Engineer's Printed Name Michael E. Anderson, P.E. 6. DSD SIGNATURE T System #1 Approved for --14- bedrooms System #2 Approved for Disapproved Conditional approval for bedrooms Phone 522-7773 Date 1/28/2015 ao ,.•- .vY 49th ,11CHAEL E. bedrooms, with the following stipulations: Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory L!051 Other COSA blue sheet t ... c If more than 1 septic system is on the lot: COSA Checklist # Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: Wagner, Tract 2 Parcel ID: 017-092-33 A. WELL DATA Well type Private if A, B, or C provide PWSID # _ Date completed Unknown Sanitary seal (Y/N) Y Total depth '75 ft. Cased to >40 ft. FROM WELL LOG Date of test Static water level ft. Well production 9— P.M-WATER SAMPLE RESULTS: Coliform --i—colonies/1 00 mL Nitrate .688 mg1L ND 1!12/16 Arsenic ug/L Date of sample: B. SEPTIC/HOLDING TANK DATA, Tank Type/Material Septict$teel Tank size 1,250 gal. Number of Compartmentsa., Foundation cleanout (YIN) Y Depression over tank (Y/N) N Date of pumping New. Const. Pumper Well Log (Y/N) N Wires property protected (Y/N) Y Casing height (above ground) >18 in. AT INSPECTION 11/12/15` 43.3 ft. 9— P.m- Collected by Anderson Engineering Date installed 5/8/2015 Cleanouis (YIN) Y _ High water alarm (Y/N) N C. ABSORPTION FIELD DATA Date installed 5/8-11/15Soil rating (g.p.d.M2 or fe/bdmt) .45 GPD/SF System type peep TrefiCtt Length 2 9 42' ft. Width 3 ft. Gravel below pipe 8. ft. Totai depth 1'2- ft. Eff: absorption area 1,344 f Monitoring tube Y Depression field, N Date 61,adquaeystiy4a1/yU11St. Results.(Pass/Faii)-�^ For bedrooms Fluid depth in absorption fleld;before test in. Water added ' gal. New depth in. Elapsed Time: mih. Final fluid depth in Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) If yes, give date r- D. LIFT STATION Date installed Size in gallons Manhole/Access (YIN) "Pump on" level at in. "Pump off level at in. High water alarm level at in. Datum Cycles tested Meets alarm & circuit requiremerns? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tanklIft station on lot >100' Absorption field on lot >100' Public sewer main >75' Sewer /septic service line >25` Animal containment areas >59. SEPTICIHOLDING TANK ON LOT TO: Building foundation >5' Property line >5' On adjacent lots >100' On adjacent lots >100' Public sewer manhole/cleanout >100' Holding tank >75' Manurelanimal excrete storage areas >100' + Absorption field >5 Water main >10' Water service line >10' Surface water >100' Weiss on adjacent lots >100' ABSORPTION FIELD ON LOT TO: + >10 >10 Property line >10 Building foundation Water main >100 Water service fine > 10 Surface water Driveway; `parkinglvehlde storage > 10 None Noted >100' . Curtain drain Wells on adjacent lots , ;1. -CM brown sheet 10-16-12.doc Municipality of Anchorage Development Services Department P ' Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 Water Well Advisory Certificate of On -Site Systems Approval (COSA) # osc161021 During a recent COSA on-site inspection and test of the potable water supply well on Block , Lot Track 2 of Wagner subdivision, the well's productivity was determined to be 0.8 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a 4 -bedroom residence is 0.58 gallons per minute. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. 10/02/2015 23:69 907-345-0202 ALPINE DRILLING PAGE 01/01 Development Services Department Building Safety Division �• b` b On -Site Water A Wastewater Program 4700 Elmore Road q P.O. Box 196650 MarkEegich Anchorage, AK 99507 Mayor www mVri oro/o fi (907')343-7904 Pump Installation Log Well Drilling Permit Number: SW j+a Date of Issue; Iia Parcel Identification Number:__ Legal Description Property Owner Name &Address: Wagmr Tract 2 Erik riialm 14551 Goiden View Dr. Anchorage, AK 995i8 Pump Installation Date: 19.2016 — — Pump Intake Depth Below Top of Well Casing: 76 feet Pump Manufacturer's Name: cmr;iae Pump Model: 7wS05 Pump Siff .s hp Pities Adapter Burial Depth: 14 feet Pitless Adapter Manufacturer's Name; MaMneon Pitless Adapter Installer: fila Well Disinfected upon ComplMioD? ® Yes ❑ No Method of Disinfection'- Comments: isinfection: Comments: Pump Installer Name: Aurow Pump & We115e"ira, LLC P.O. Box 110496 Anohnmge, AK 99511-4496 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. M