Loading...
HomeMy WebLinkAboutHANKS LT 2C-2Hanks Lot #011-122-79 Municipality of Anchorage On-Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP161155 PID Number: 011-122-79 Dwelling: ❑i Single Family (SF) ❑ Duplex(D) El Multiple (SF and/or D) Project: ❑■ New ❑ Upgrade Name: Duane Hippe & Shelly Laws ABSORPTION FIELD Address ❑ Deep Trench ❑■ Shallow Trench El Bed ❑ Mound 7925 Jodhpur Street ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade (907) 360-3090 4 0.6 GPD/SF 8.8/8.1 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 4.8/4.1 Ft.4.0 Hanks Ft. 2C-2 Fill added above original grade Gravel length Township Range Section 0.0/0.0 Ft. 100 Ft. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES 5.0 Ft. Ft. To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches Tank Field Lift Station Tank Line 1000 Ft2 2 From 10.0 Ft. Well >100' >100' N/A N/A >25' TANK 0 Septic ❑S.T.E.P. 0 Holding 0 Other Manufacturer Capacity Surface Water >100' >100' N/A N/A Anchorage Tank 1250 Gal. Material Number of compartments Lot Line >5' >10' N/A N/A Steel 2 ' NA Foundation >10' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Pump on level at Pump off level at High water alarm at in. in. in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank Tank to D3034 Installer D3034 drainfield GLW Enterprises Drainfield D3034 CO/MT D3034 Inspector MEA BENCH MARK (Assumed elevation) 100 ft Inspection 1 S 8/11/16 2nd 8/15/16 Location and description 3r0 8/16/16 4hh Bottom of siding on SW wall. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL _�"tet\\NN ' .99 'A�'�1k1 Conditional Approval: Date AN •• • •' -5,r..1 *: 49 TH /.‘ ••*y % 113...t.d E 0.;:i2.4p rj N • Michael E.Anderson 11,"<`• 4381-E .'.` � Approve `^-\_, /' Date Si,S7/ ik PROFESS\O Inspection Report_9-1-12.doc HANKS SUBDIVISION, LOT 2C-2 PERMIT # OSP161155 PID # 011-122-79 ' , I I j \ / L __J SEPTIC AREA I / / LOT 1A ALTERNATE SITE Ph \ / \ / 1250-GAL 1 N / SEPTIC TANK t) ____ _ — --- - c0a \ \• �\\ A B O MT4 \ \ \ \. I f2 2C01 22.6 24.6 LOT 2C-1 j• cot •MT1 rH#lq\� ���\ w SV1 17.0 29.7 .% ` .t 2CO2�i •\ \ \� 4 SV2 12.4 36.2 ' / Two 4-BDRMHOME \SV�2 iz,\ �\� 2CO2 11.7 38.8 / CO1 22.6 43.6 r • \ A MT I F MT1 22.9 44.0 SEPTIC AREA /> / • ` \ CO3' D CO2 37.0 83.6 / / . MT2 a MT2 36.8 83.3 / / 1 0 CO3 43.0 85.8 ' /// I WELL -•\:, I MT3 42.6 85.4 K I CO4 43.5 56.5 LOT 2C-2 MT4 42.8 55.6 _ �. 10' UT1Lf1Y & T. dl E. ESMT. \ 2x LONG‘c 5' WIDE, 4' \ No Conflict with Septic / EFFEG/TIVE DEPTH System This Lot. A1SORPTI N TRENCHES -1 \ / / �%,OF` /* \\ LOT 3 / / LOT 4 �•.r\�•O ..A 1 N / / VeA 1 49?H •�•*.NOTE: LEGEND of .. ••• •' I NO SLOPES>25%WITHIN 50 OR SURFACE WATER WITHIN 100'OF THE PROPOSED SEPTIC SYSTEM CO-CLEANOUT • ... • 2C0-DOUBLE CLEANOUT 0#1.0:-.MICHAEL E. ANDERSON : i ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN.NO CONFLICTS WITH FCO-FOUNDATION CLEANOUT s: CE-4381 =``�", WELLS OR SEPTIC SYSTEMS. FS-FLOW SPLITTER VALVE 'Pe ••. �. .•c,a' MH-MANHOLE ,���D•'•••...• ' • 0 50 100 ,11k;�F;WiV;���� ME MI = FEET MT-SV-SEPTIC VENT ING TUBE 1"=50' TH-TEST HOLE HANKS LOT 2C-2 PERMIT # OSP161155 PID # 011-122-79 o > > 0 U) N - ,/-97.5 — — — 92.8 7r 92.2— 1250 GAL 92.0 SEPTIC TANK 1/ / `�87.9 OH TRENCH #1 HO �-96.7 FINAL/ORIGINAL GRADE U r 91.9 DRAINFIELD ROCK 91.9 �''--87.9 50' 87.9----A..- _I TRENCH #2 O� t�96.OFINAL/ORIGINAL GRADE �0 l Il V 91.9—� a DRAINFIELD ROCK 91.9 ��87.9 87.9 50' 7-81.0 NO GROUNDWATER 6/24/16 �.�_OF \ill , I *49.•' TM N) %I 1, *lilt /\ •.* / PROFILE AS-BUILT rhc- MichaelE Anderson.�,�i E 4381 (NO SCALE) `l, F�PROFESSIONP`s H5,'25: 1017 23:00 907-345-?.I202 ALPINE tRILLI^Y, PAGE �]2;t31 Alpine Drilling & Enterprises Well Log Permit Number: #1SW 16�g5 Date o#'Issue: 6:1.17..16 Date Starred: l a.8-iS Parcel Identification Number: p11122�91� Date Completed: 10-11.16 Is well located at a Legal Description: Hanks Lot 202 approved Proporty Owner Name&Add permit location?x Ycs 0 No mss: Il�pe Duane &Laws Shelly 8295 Opel Drive Borehole Data: Anchn;:.e, Alaska 99502 Depth{try -�- --_... Method ofD Soil Type, Thickness Water Strata Drilling x air rotary 0 cable tool From To i ___••••=..•-••=.-•-•-•••• stick-up Casing tarps.steel __"�___ .--__ organics&sill 0 2 Wall Thickness:_250 inches • silt 2 3 Diameter:4 inches Depth:261 feet 3 S Irner Type:_� sandy silt •5 bDiameter: ,�.inches D ,3 � �: feet gravelly sarr[{y silt ._ Crim etiekup above ground:2 fitet 63 102 Static wager level from t silly,sand moist102 ( round level):171 fast 104 Pumping leve/:_261)feet after 2 hours pumping silt 104 104 rxtrn p g 40+g,t R sandy silt Recovery 109 173 I Rate:1Q± , gravelly'scum,silt Method of Testing: 173 __ gy l ift water sand$gravel 255 Well Intake ninT -� ---- -___ 255 261 x Open EndOpenpen Hole 0 Screened Start____feet Stopped ❑Perforations S� _ feet _, Stopped fact Grout Type: bentonite snarl c -�'eD.SI?' Volume: .f. rt Q St..,,40 ?feet 4 . Pump:Intake Depth feet Pip sizesy hp Brand Name WATER qyq�,ITY TESTING Nitrates Coliform � Col/100mL � I _ Well Disinfected Upon Completion?x Yu; '1 mg/L ._ Method of Disinfection: - _ ppts` 0 No z� eta -� Arsenic ,D ug/L Comments: - ___.. Well Driller: Alpine Drillin►&Ente prives PO Box.110496 Anchorage AK 99511 I i � t 1 L___ - -- --- —� -. _ _ Relinattifilifii UV 4N. c F FM (5q ,,-7670 i 7 ., 03/22/2eii 7 23:51 907-345-a202 AL.F'INE DRIL.L.ING PAGE 01/61 Development Services Department • Building Safety Division • • .1-P. On-site Water & Wastewater Program r°s_: a 4700 Elmore Rood .,rl,r'I-"` P.U. Box 196650 p .:a: - MN*Beglch Anchoro9e, AK 99507 . S A (TY Mayor .www,!nu or9/onsite (90?)343-7904 Pump Installation Log , Well Drilling Permit Number: SW.:� 1 Date of Issue: 1f 24� i! 1F' p� Parcel Identification Number:. !-i -1iooO Legal Description Pro er O per Nam &Address: Lot C. �. [il1 i, 1Tl e, e!, i�-1�, fy 'j�l� E IL . •),`�J a 61 t om'. _fit - _ - c !`tom 1'�+ � Pump Installation Date: 1-17-7-1 i;7...0:-.4_ -- Pump Intake Depth Below Top of Well Casing: Peet Pump Manufacturer's Name: 640/410-5 Pump Model: 10'5 14 ID Pump Size hp L P.itless Adapter Burial Depth:il)f feet f Pitless.Adapter Manufacturer's Name: lt? -41 ?loess Adapter Installer: iJ 1 i . Well Disinfected Upon Completion?4 Yes L I Na Method of Disinfection: Comments: 1 y .) Poi '' . ............====._ Pump Installer Name: mow Plop&Via Unice P.O.kc 110496 AnnkiY! ge, AK 9951I-049k Attention: The pump installer shall provide a pump installation log to the DSD witain 30 days of pump installation MI IN X IL. •lilt r.aim Permit Number: Tax Code Number: Work Type: On-Site Water & Wastewater System Permit OSP161155 01112279000 WellSeptic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Initial Permit Effective Dates: June 24, 2016 to June 24, 2017 Design Engineer: ANDERSON ENGINEERING Subdivision: HANKS Site LegalAddress: HANKS LT 2C-2 G:2222 Owner/Address: HIPPE DUANE & LAWS SHELLY 8295 OPAL DR ANCHORAGE AK 995020000 epartment Site Mailing Address: Lot Size in Sq Ft: 56308 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (16AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343~7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. , / MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 011-122-79 Property owner(s) Duane Hippe and Shelly Laws Mailing address 8295 Opal Street Anchorage, AK 99502 Day phone 243-1274 Site address NHN Jodhpur Street Anchorage, AK Legal description (Sub'd., Block & Lot) Hanks, Lot 2C-2 Legal description (Township, Range & Section) LotSize 56,308 .Sq. Ft. Number of Bedrooms .F°ur(4) APPLICATION IS FOR: ([~ all that apply) Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] APPLICATION I$ AN: Initial [] Upgrade [] Renewal [] TYPE OF DWELLING: Single Family (SF) [] (w/wo ADU) Duplex (D) [] Multiple Dwellings [] (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Dis tance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. (33P[ul155 ~' '"~V~lver Fees: Date of Payment: Receipt Number: Waiver No, Permit App_9-1-12.doc June 8,2016 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Su~ect: Lot 2C-2, Hanks Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 2C-2, Hanks Subdivision intends to construct a new four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells and septic systems on surrounding lots. No conflicts exist between the proposed septic system and well or septic systems and wells on adjacent lots. Drainage arrows and ground surface contours are shown on the site plan indicating the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. A test hole was placed on the lot in the area of the absorption trenches and altemate site. The log indicates silty sand (SM) in the zone specified for the absorption trench. The pemolation rate of the soil was determined to be 24 minutes per inch. No groundwater was found during the placement of the test hole and none developed during the monitoring period. An application rate of .6 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250-gallon septic tank and 2-50' long by 5' wide by 4' effective depth absorption trenches to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 3' below the surface and the total depth will be 7'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the septic system slopes to the east. The new trenches will be constructed parallel with the contours of the slope as much as Lot 2C-2, Hanks Subdivision June 8, 2016 Page Two possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those'to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments 50' ). I ,/' H"~nks SU--b~TvTsT 0 Lot 1 ~ ~ 40,168 o c. sq.ft. ~. ~ Lot 2 40,262 sq.ft. SO0' 13'$6"E 114.01' 134.00' S89'51'10"W 329.76' 249.69' 113.95' 134.00' 50.03' Gos Esmt T&E Esmt ~ Lot 9 o ~ sq.ft. ~ "I0' Utility Esmt ..... 133.00 ..... Lot 8 40,250 sq.ft. 2C-2 Let 5 k 10' T&E Esmt-~. \ ---~--134 O0 ........ Y ....... 223.06 ..... .~-- ~ ~ .~ ~ ' · , Rotc ffb Subd v s on ' 2 ' I'''''~ ...................... ~'"'~ SCALE 1' = 100' LOT 2C-2, HANKS SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home 5' Wide Trench System Perc. Rate: 24 Min./Inch 1,250 Gallon Septic Tank Application Rate: .6 GPDISF 4' Drainfield Rock 4 Bedrooms * 150 GPM/Bedroom ~600 GPM Design Flow 600 GPDI.6 GPD/SFI5 SF (Width) .5 (Red. Factor)= 100 LF Trench Length THEREFORE: Construct 2-50' Long x 5' Wide x 4' Effective Depth Absorption Trenches. Flow Line Elevation in Trenches to be 3' Below Original Ground Surface. Total Depth to be 7' Below Existing Ground. Provide 3' Cover Over Absorption Trenches and 4' Cover Over Septic Tank. 6# /Geotextile Fabric ~ 4" Perforated PVC (Holes Down) Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION ,NOSCALE, ........... .. %:..' ..~_;'..,~, ~. NOTE: Grade Area Over Trench. to Drain Away. ~ ~ 49th Minimum 6'. Separation From Bedrock. ~..2~%...~.....~.,.~...,~ Minimum 4 Separation From Groundwater ~~,~, Minimum 100 Separahon From Private Wells In the Area. ~ Minimum 100' Separation From Su~ace Water or Streams.'~;~.,. No. 4700 DEPTH 1 2-- 3 4-- 5 6 7 8 9 11 lv]UNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 2-C-2, HANKS SUBDIVISION PERFORMED FOR: SHELLY LAWS AND DUANE HIPPE DATE: 6/6/2016 PARCEL ID#: f"IE A OL SILTY SAND SM B0H @ 15' PROJECT No.: TECHNICIAN: TESTHOLEA I WAS GROUND WATER ENCOIJNTERED? IF YES ~ WHAT DEPTH? DEPTH OF WATER AFTER MONITORING: SLOPE No NONE ~O DATE OF MON1TOPd-NG: 6/24/2016 ~ Professional En~neem Stamp: SITE PLAN SEE SITE PLAN DATE READ NO GROSS TIME NET T MEI DwE%~-I~RTO INET DROP (MINUTES) I(MINUTES) I (iNCHES) I (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 6/6 I 11:04 2.25" 2 11:34 30 3.50" 1.25" 3 11:35 2.13" 4 12:05 30 3.38" 1.25" 5 12:06 2.25" , , 6 12:36 30 3.50"1.25" I I PERCOLATION RATE: 24 (MIN/INCH) PERC. HOLE DIA. 6" .(INCHES) TEST RUN BETWEEN: 4.0 FT. and 5.0 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 6/9/2016 rr Tl 7 8 9 t l� I • y6 70 "k AA Municipality of Ancho : y ‹.) On-Site Water and Wastewater Pros -m (907) 343-7904 a MAY 3 0 2018 N-6 1Ti �d v ti Certificate of On-Site Systems A • . 'vat a 6 8 L (� 011 ,...\`u l f Parcel I.D. -122-79 Expiration Date: — —C E 1. GENERAL INFORMATION Complete legal description Hanks Lot 2C-2 Location (site address) 7925 Jodhpur Street Current Property owner(s) Duane Hippe & Shelly Laws Day phone 360-3090 Mailing address 8295 Opal Drive, Anchorage, AK 99502 Real Estate Agent Day phone 2. TYPE OF DWELLING: Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well El Individual 0 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: Il , ln(l�WAM Date: 67////�/COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ /ILO Waiver Fee $ Date of Payment 573jl/9 Date of Payment Receipt Number 05- g(44) Receipt Number COSA# QSI.'�7j (i3 Waiver# 5. STATEMENT OF INSPECTIONr �34814 N As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Forge Engineering Phone (907) 522-7773 Address PO Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, PE Date 5/30/18 — OFAgk / co ., - . 7 �� l *: 49 TH /\ 6. DSD SIGNATUREI%t , , 6 �_, >e System#1 Approved for 7 bedrooms 4 F Michael E.Anderson re,/'es'% 43&1-E, .•.`./ System#2 Approved for bedrooms , e'. 5 0.,. Disapproved l,`\�����''. Conditional approval for bedrooms, with the following stipulations: �J�c�pNur),o,.�, ON �; C) 1414S/7, �iST 'gN0 0ARp � / –Gly tai) By: A `tom_\:7– I Original Certificate Date: G - 1 -Cg The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet_. .. If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: Hanks Lot 2C-2 Parcel ID: 011-122-79 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) Y Date completed 10-11- v Y p � Sanitary seal (Y/N) I Wires properly protected (Y/N) Total depth 7-6( ft. Cased to 2 6 1 ft. Casing height(above ground) 2 Y in. FROM WELL LOG AT INSPECTION Date of test 1 U_,t L L /\)e.UJ Static water level 11 t ft. ft. LA0 4- Well production g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform N el colonies/100 mL Nitrate ME) mg/L Arsenic Nil) ug/L Date of sample: 5/25/18 Collected by: Forge Engineering B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 8/11/16 Tank size 1250 gal. Number of Compartments 2 Cleanouts(Y/N) Y Foundation cleanout(Y/N) Y Depression over tank(Y/N) N High water alarm (Y/N) N Date of pumping Pumper New Construction C. ABSORPTION FIELD DATA Date installed 8/15-16/16 Soil rating5-Wide (g.p.d./ft2 or ft2/bdrm) 0.6 GPD/SF System type Length 50/50 ftWidth 5.0 ft. Gravel below pipe 4.0 ft. Total depth 8.8/8.1 ft. Eff. absorption area 1000 ft2 Monitoring tube Y Depression over field N Date of adequacy test New Results (Pass/Fail) For bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment(past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: >100' On ad scent lots >100' Septic tank/lift station on lot 1 >100' On ad scent lots >100' Absorption field on lot 1 Public sewer main >75' Public sewer manhole/cleanout >100' Sewer/septic service line >25' >75' Holding tank >50' >100' Animal containment areas Manure/animal excrete storage areas SEPTIC/HOLDING TANK ON LOT TO: >1 0' >5' Absor tion field >5' Building foundation Property line P Water main >10' Water service line >10'10' Surface water >100' Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: >10' Property line >10 Building foundation >10' Water main Water Service line >10' Surface water >100' Driveway, parking/vehicle storage >10' Curtain drain adjacent Noted Wells on adjacent lots >100' F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and .4 F A \i` review of Municipal records that the above systems are in ��G• •.....:57°00 1, conformance with MOA COSA guidelines in effect on this date. �� P' •'•'�-y°+ Michael E. Anderson, PE %*.'49 THA •.*��� Engineer's Printed Name 1� . Date 5/30/18 '. Michael E.Anderson . j /4 lF%• 4381-E .•��,/ tkk\. 'PROFESSIO*'.� i,\\\���~1 COSA brown sheet_10-10-12.doc HANKS SUBD. Lot 1 C 0 v "D Zo N 89'57'31"E 609.65' C No Z7 r� o o GRAVES ORlV 1.4"j 0o EwAY. (� S 89'57'31"W 100.00' i 36.8' �' �r '� �0 0 N 82'34'48 s.. ka o 23 10' UTILITY, 231.40' / t 83 `•A 6 0 •S Z ri T&E EASEMENT �o� `z2 0, `�, CANT c> iT7 BALCONY v' D. —Iopt 0 o p • �m c� .7 SEPTIC 0 / s2 s� rri Z • o •1a.5' z.,,n' \ PIPES P. 0 o / 107.5' �' 6.1' 50.0' _ � j y O r• 28.7' p X11.0' \23. A v •'' q' e) .6� - 2.2' rn Lot 2C-1 ci 1.a o .111°5.5''t" 3.8' ' 03 Lot 2C-2 56,308 s.f. PROTECTIVE RACIUS o 100' cn I UTILITY, ,,k i _ 0E EASEMENT WELL _____—( — — — — — S 89'58'02"W 280.41' / Tract A / JOHNSTON SUBD. \ , I o m - -- o PLOT PLAN AS BUILT X SCALE 1" = 50' _ GRID SW 2222 Project No. 16-092/64 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates , inc . (907) 522-6476 Phone 4QOp0�4 (907) 522-4625 Fax o 0 F g C o ,p Professional Land Surveyors kenOlangsurvey.com •• •=r' :. 9 jonathanOlangsurvey.com fcz)1/ 7.. ..4... O . 6\T%I hereby certify that I have surveyed the following described property: � 'LOT 2C-2, HANKS SUBDIVISION (PLAT 2005-46) 9TH �� QD Anchorage Recording District, Alaska, and that the Improvements situated thereon are 0 within the property lines and do not encroach onto the property adjacent thereto, that a no improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission linesQ or other visible v0�� '• KENNETH l�G p 1easements on said property except as indicated hereon. pi, 5[ 4 pF •.LS-520?.•' SJo Dated this the _-_ Day of , at Anchorage, Alaska 0O,,,A4, IONAL�o� It Is the responsibility of the owner to determine the existence of any easements, �Opppoo'z' covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963