HomeMy WebLinkAboutPITZER Lot 31 (Later subdivided) (U.S.S. 3201)
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264~4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME [PRONE ~JNEw
DALLAS PITZER E] UPGRADE
MAI LING ADDRESS
~EGAL DESCRIPTION
_0T 31 U. S. SURVEY NO. 3201
NO, OF BEDROOMS
LOCATION
BIRD CREEK
- Well
I DISTANCE TO: '~
I.- Z I Manufacturer
~ I NA
~ I Liq. ~a~acity in gallons']'
r~ ,. '~' DISTANCE TO: ]WedFI
HOMEMADE:
- ~ I IWell
~ = ~ DISTANCE TO: I NA
~ ~ ~ ~ N~ o~ines ~ Length of each hne
~ ~ I Top of die to fi~sh grade
~ Width
~ ~1~ Depth
I Absorption area Dwelling
NA Mate,.ti~½'
Inside length Wid~
PERMIT NO.
_AA
No, of compartments
Liquid depth
Dwelling PERMIT NO.
Liquid capacity in gallons
Material
Foundation Nearest lot line
NA NA
Total tength of lines I-T~ width --
/
inches
Material beneath tile
inches
Depth
PERMIT NO.
Distance between lines
Total effective absorption area
PERMIT NO,
Crib depth Total effective absorption area
Building foundation Nearest lot line
Driller Distance to lot line PERMIT NO.
Sewer line Septic tank Absorption area(s)
OTHER
PIPE MATERIALS
NA
SOIL TEST RATING
N^
INSTALLER
NA
REMARKS
SUBMITTED FOR ASBUILT
ONLY
APPROVED
72-013 IRev. 3/78}
DATE LEGAL
NAME
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PRO'FECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street - Anchorage, Alaska 99501 Telephone 2,64-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Dalla~ Pi t ?_~r~
MAILING ADDRESS
rPHONE
I[] NEW
[~ UPGRADE
LEGAL DESCRIPTION
Lot 31 U.S, Survey No. 3201
LOCATION
Bird Creek
-- I Wall
I DISTANCETO' I 130'
_~v '
~ I Manufacturer N.A.
ILiq. capacity riga ons ,,
- I 2500
- ~ I IWe,
m'r I DISTANCE TO: ] 160'
~ ~ ~ I N~ ~in~ength ;~ each line
~ I ~P ~i~ ~ fihish g~de
-- I ~ngth ~tb
~ ~ Type of crib Crib diameter
d ICl~s D~th
NO. OF BEDROOMS
one
tDwelling 28 I
Material
inside i~hT~, IWiot~ ' St.ee~l
Absorption area ,. PERMIT NO. N.A·
No. of compartments
Dwelling
Material
N~r~st lot line
Wes t LJJ~e
Trench width
48 inches
Foundation
75'
Total lengtl~ of lines
40'
Material beneath tile
Liquid depth
PERMIT NO.
Liquid capacity in gallons
PERMIT NO.
N,A_
Distance between lines
Total effective absorption area
inches
Depth PERMll' NO.
Crib depth Total effective absorption area
Building foundation Nearest lot line
Driller Distance to lot line
Sewer line Septic tank
DATE LEGAL
OTHER
PIPE MATERIALS
Cast Iron & Steel- ~/4" Perforated cup
SOIL TEST RATING
GM @ Tank
INSTALLER
REMARKS
]nsf. ailed in duly 1975, up_oraded ~n ~979,
_6W material in drain field area/.
APPR OV E D.~
lPERMIT NO,
A/hmicipa .ity
Anchm-age
825 "L" STREET
ANCHORAGE, ALASKA 99501
(907) 264 4111 ,,
,r ,'t LL IX" AN,
[:i P'"I{ TM!:r,~I ()1 IH Al TH At'd) (:NVIHON,",~[ '~TA[ I,ttO rF:C'rION
Set.)tember 9, 1980
Melvin R. Nichols, P.E.
ALASKA TESTLAB
4040 B Street
Anchorage, Alaska 99503
Subject: U.S. Survey #320]. Lot 31 (lot 2)
Due to the soils log submitted to this department showing
a 10% silt, a percolation test will be required on the
above property.
Any soils showing a percentage of silt over 5% requires
a percolation test to be done.
If there are any further questions, please call this
department at 264-4720.
SJ. ncerely, .~
'/
~ /. 7',, '.'.,/ ·
John W. Lynn
Environmental Specialist
JWn/1 j w
Jerry Weaver
Planning Department
~--~--~'" L ~ '~'", ~' ' .... R E E T
'/~ ~ ~ , ~, ,' 4040 B St ;:z ~,~,
~ "'X '!~. ~ [: "' .... ANCHORAGE, AL. ASKA 99503
qL~q~k · % :,. ,,~¢,. (907) 278-1551
', ¢, ', ,.,:,' . ?' October 7, 1980
~%?' ;~,_'i'~' ' , ,,,~" W.O. ~A1 9 4 1 2
.... ?' " //~'" ~ MUNICIPALITY OF ANCHORAGE
Mr. Ken Stephenson
6216 Old Seward llighway
Anchorage, AK 99507
Subject: Percolation Test on Lot 31;
U.S.S. 3201 - Bird. Creek
Dear Mr Stephenson: t ~ "~ ¢
This report is supplemental to our report dated August 14,
1980 and contained in the appendix of this report. The
DEPT, OF HEALTH &
ENVIRONMEN1'AL PROTECTION
00T7 1980
R, ECEIV [D
purpose of this additional work was to perform a percolation
test at the site.
A second test pit. was dug to the east of the original explora-
tion. That pit. ~s located on the enclosed test pit location
sketch.
The soils J.n this second pit varied considerably from those
in the initial test pit. They were considerably siltier. A
percolation test was run in the pit at 12' of depth. The
results of that test for the last 20 minutes of the test was
10 minutes/inch.
The soils got cleaner with depth from about 8.0' We,
therefore, recon~end placing the absorption trench between
8.0' and 12.0' below the ground surface.
No ground water was: encountered in either test pit...
¢~ 3. ilc e ¢. e.l.y,
MRN: rb
Enclosures
_ I,'.,S l LAB
ALASKA m' ,~ ·
l~e.].vJ.n R. Nichols, P.E.
Laboratory Manager
· ,
I~t°b" te ]
I~/ T L. O C ,O TI 0 8/
,c',~9 vi e I
Test Hole #2
Date: Sept. 30, 1980
Logged By: O.~4. }latch
W.O. #A19412
Depth in Feet
From To
0.0' -. 6.0'
6.0' -- 9.0'
9.0' -- 11.0'
11.0' - i3.0'
SOIL DESCRIPTION
F-4, brown Sandy Gravelly Silt, ML.
F-l, brown Sandy Gravel with some silt,
GM.
NFS/F-l, brown Sandy Gravel, GP/GM.
F-l, brown Sandy Gravel, GM, with some
silt.
Bottom of Test Hole:
Frost Line:
Free Water Level:
Remarks:
13.0'
None Observed
None Observed
Percolation Test at 13.0' was 10 min/inch.
4040 "B" STREET
ANCHORAGE, ALASKA 99503
(907) 278-1551
August 14, 1980
W.O. #A19412
Area 2
Ken Stephenson
6216 Old Seward Highway
Anchorage, Alaska 99507
Subject: Test Pit Exploration for Septic System Design, Lot 31,'
U.S. Survey 3201, Section 9, Township 10N, Range 1W,
Seward Meridian
Dear Mr. Stephenson:
At your request,' Mr. Dave Paul, senior engineering technician,
logged a test pit on the subject property on August 7, 1980. The
property is near Bird Creek on the Seward Highway south of Anchorage.
The test pit was dug while Mr. Paul was present with a backhoe
which you contracted.
The soils encountered are graphically shown on Figure 2 attached
to this letter. The soil from the surface to 2.5 feet was a
brown sandy gravelly silt. Below this layer is a dense sandy
gravel having about 10 percent silt. The gravel is well graded
and has occasional cobbles. A grain size distribution test was
conducted on a sample of this soil. The results are attached as
Figure 2. No ground water was encountered. The sandy gravelly
silt is impervious, but the gravel underlying the silt is permeable.
Based on our experience with simila~ soils, we would estimate its
permeability is on the order of 10-- centimeters per second. We
recommend that the septic system drainfield be designed to provide
150 square feet of absorption area per bedroom. The system
should be designed and constructed in accordance with the Municipality
of Anchorage regulations.
The following are attached and complete this report.
· Ken Steph~nson
A,,,j~St 14, 1980
Page Two
.~ ~,_, ....
Test Pit Location Sketch
Test Pit Log
Grain Size Distribution Curve
Standard Explanatory Information
Figure 1
Figure 2
Figure 3
Sheets 1-2
If you have any questions, please contact our office.
Sincerely yours,
ALASKA TESTLAB
R. Finl' ,
, Jr. P.E.
Geotechnical Engineer
JRF/mg
Approved by:
Melvin R.
Manager
Nichols, P.E.
Attachments
DEPTH
0
5
TEST
RES~JLTS SAMPLES
13
MA Sheet 1
.T. EST KEY:
W-' MOISTURI~ CONTENT
LL '- LIQUID LIMIT
PL: PLASTIC LIMIT
MA, MECHANICAL ANALYSIS
TEST PIT
WORK ORDER A 1 O ,I 1 2
LOGGED BY D. Paul
ELEVATION = N E
DEPTH
F-4, BROWN SANDY GRAVELLY SIL%,
MOIST, NON-PLASTIC
2.5t
NFS, SANDY GRAVEL WITH APPROXIMATELY
10% SILT, FINE TO' COARSE, WELL-GRADED
OCCASIONAL COBBLES, MOIST
14'
BOTTOM OF TEST PIT MAXIMUM REACH OF
BACKHOE. COb1PLETED 8/7/80. NO
GROUND WATER ENCOUNTERED.
LOG OF TEST PIT