Loading...
HomeMy WebLinkAboutRANDOM HEIGHTS LT 4 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP221439 Work Type: Septic Upgrade Tax Code Number: 01741108000 Site Legal Address: RANDOM HEIGHTS LT 4 G:2841 Site Mailing Address: 12725 GINAMI ST, Anchorage Owner: LYNCH EDITH V Design Engineer: GARNESS ENGINEERING GROUP LTD This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft Total Bedrooms: 1'R__ �ZNcnr U• ll�parrmcnr 11/23/2022 11/23/2023 46747 Q Disposal Field Cl Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing .Z55tAl—J f0 (rEG Date: Issued By: �{% Date: 2 4 Municipality of Anchorage \� Ue p;;rtment N P.O. Box 196650 ® 4700 Elmore Road Anchorage, Alaska 99519-6650 e (907) 343-7904 • Fax (907) 343-7997 http://www.rnuni.org/Onsite Development Services Division On -Site Water and Wastewater Program * * * * VARIANCE/WAIVER REVIEW * * * * Waiver#: OSV221077 COSA#: Permit#:OSP221439 PID#: 017-411-08 Legal Description: RANDOM HEIGHTS LT 4 Engineer: Garness Engineering Group Your request for a waiver of the required 6 foot horizontal separation from the absorption field to the existing absorption field has been approved. The approved separation distance is 8.0 feet. In addition, the field is approved to be on a slope less than 45%. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on- site wastewater disposal system will require all separation distances be met or another approval from this department. ............................................... ■ ............................. ■ 1 Waiver is Granted: X Waiver is not Granted: Date: Z3 Z Approved by: Name of Reviewe ............................................................ ................� **** VARIAN C E/WAIVER REVIEW **** Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/VVELL PERMIT APPLICATION Parcel I.D. 017-411-08 Property owner(s) EDIE LYNCH Day phone 907-345-5225 Mailing address 12725 GINAMI STREET *ANCHORAGE, AK Site address 12725 GINAMI STREET *ANCHORAG,E AK Legal description (Sub'd., Block & Lot) RANDOM HEIGHTS; LOT 4 Legal description (Township, Range & Section) Lot Size Sq. Ft. Number of Bedrooms 4 APPLICATION 1S FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field 0 Initial ❑ Single Family (SF) Q (w/wo ADU) Septic Tank El Upgrade (D) ❑ Holding Tank ElRenewal ElDuplex Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: DRAINFIELD TO SLOPES GREATER THAN 25% Distance: 0 FEET I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: d'd 0 Waiver Fees: Date of Payment: /' ;';z Date of Payment: Receipt Number: 0 / 1 Receipt Number: Permit No. G S 10 a012 1 Waiver No. 0,5 V 22.107 7 GADevelopment Services\Building Safety\On Site water and wastewater\Forms\Client ForinsTermit Application.doc �l,/I Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221439, Deb Wockenfuss, 11/23/22 r-c,-�tu r► ►- 9-�, L L¢ Page 2 of 2 unknown required separation distance down to 8 feet. Justifications for granting this wavier are as follows: • Only one of the systems/trenches will be in use at a time. • The testhole adjacent to the existing surcharged trench is dry to a depth of 13 feet; therefore, it is reasonable to believe that lateral migration of the effluent will be minimal between the new and existing trenches. 6. WELL: Per MOA records, there were two wells drilled on the property. Per conversations with the owner (on 10/12/2022) it is unknown if the abandoned well was decommissioned or abandoned. The 'old well' could not be located by GEG. It is assumed that it was cut below grade. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www. garnessengineering.com Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221439, Deb Wockenfuss, 11/23/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221439, Deb Wockenfuss, 11/23/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221439, Deb Wockenfuss, 11/23/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221439, Deb Wockenfuss, 11/23/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221439, Deb Wockenfuss, 11/23/22 > CN 0 m < OZ -90 3,.SkW.00S E 0 Q5 0 0 E 00 ro 0 'It, ry 00 m C) 0 -le E co LO E LU FU - Ou CY) LL D 0 WCl) 4 48.0 oo 03 0 �T Ul)C'4 0 04 m 48.0 "OSr- 00 z 70 u O. 0 a o. '6Z- 06 CL Ln 0 3: 9Z'99G MXS30.00N 133JiS INVNIE) �%Xlx A I I U, >1 m - .1 0 E A N w a7 m c 0 0 to a7 JL, X50 Ly cj AW —J. 0L)w W W w °`,X0 00 00 0 T- u F- ?. w 001, 00 0.. 0 00 00 ujU) N— c: C -r a) F , wa =0 2 Ow — CO W sE cc - a- 0 00 e - 15D 2 — 4w loop Z) 0 0 (D —0 m E 'v 0 > C ccun < CX —•, .6 Z ' rr pa, LLJ 2— 0 ) Lij x'.2'0 co CC 0 w 15 c cn xw a) '2 z m _(_D .n Ox, a) -.— ::) _5 m , c E E >,Sm E 709 a o 0 0 t >0 2 C;) Z x 0 C: M, CL 2 , c E 0 CL U) cn ca m a �5 2 E 0 (fi CL Lu -= 10 x c U) E.0 Q LL W mm 'E 0 Z > -J 0 cc 0- _j CL r- 0 ca m 0 a 2 3: ;z 'Om 3: 0 co < 15T -0 zg b -0 Cc F --,I- do o -,5- 2 .0 L) -i OOL r- - :S CD > - , 0 E a) CD 0 E -0 " `?Q 'E co 6 4) c a 0 m .O W (D -6 E :s E 0 o -r, < >, -2 c -E .5 2 E 00 0 > -,o 0 w 0 11 r- a) 0-0 C� o2 CL -, -= a.- 0 U) .— a) 0 -,g 2 a) m V) a)c u 0 210 :E E .5'a - W m < > LL! .2 �%Xlx A I I U, >1 m - .1 0 E A N w a7 m AW X50 Ly cj AW —J. 0L)w W W w °`,X0 00 00 0 T- u F- ?. w 001, 00 0.. 0 00 00 6i 0 LU < Aff uj c m 0 cc z T- w 0 Cl) CL U) 4w loop Z) 0 0 (D —0 m E 'v 0 > 0 .2 Z W -Z X50 Ly cj O 0L)w W W w °`,X0 w z z 0 T- u F- ?. w w Z 0 W 6i Ir 0 LL- Z 0 S 0' Ul < 0 z I-- z T- w 0 Cl) CL U) U) 2E W < (n w U) ui U) 0 - � < T- --j Z w F- CL D GREA,FR ANCHORAGE AREA BORudGH Department of Environmental Quality 3330 C Street Anchorage, Alaska gg503 NAME LOCATION INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: DISTANCE ,! FROM WELL -/C~ INSIDE LENGTH MANUFACTURER~ INSIDE WIDTH MATERIAL ,:~g0 LIQUID DEPTH NUMBER OF ____COMPARTMENTS LIQUID CAPACITY/<~'~'~ GALLONS. DISTANCE FROM WELL NUMBER OF LINES ABSORPTION AREA DEPTH: FOUNDATION DISTANCE BETWEEN LINES SQ. FT. LENGTH OF EACH LINE DEPTH OF FILTER TOP OF TILE TO FINISH GRADE ~1 TOTAL LENGTH NEAREST LOT LINE OF LINES TRENCH WIDTH~(~ IN. TOTAL EFFECTIVE MATERIAL BENEATH TILE IN. ABOVE TILE ~'J/' IN. WELL: TYPE BUILDING FOUNDATION__ CESSPOOL APPROVED CONSTRUCTION NEAREST NEAREST SEPTIC LOT LINE__, SEWER LINE TANK__ , OTHER SOURCES DISAPPROVED REMARKS DEPTH SEEPAGE , SYSTEM DISTANCE FROM: DISTANCES INSTALLED BY: ~ SEWER LINE DEPTH: PIPE MATERIAL:~'~ LOT SLOPE: ~-/~ ~ REMARKS: DIAGRAM OF SYSTEM GEe/ zr ANCHORAGE Area BoL Ugh DEPARTMENT OF'ENVIRONMENTAL QUALITY ' ~ PERMIT NO.; SEWAGE DISPOSAL SYS'i:EM -- APPLICATION AND PERMIT ~~ INSTALLATION OF: SEPTIC TANK SEEPAGE PIT . DRAIN FIELD OTHER sO[~ ~EST RESULm~ --1~-- 7~~ NOT=, THIS PERMIT IS NOT VALID WITHOUT SOIL TEST m' / COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL (~UALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE 1~:~'~) TYPE MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK . SEEPAGE PIT . TO NEAREST LOT L'NE. WELL TO SEPTIC TANK DRAIN FIELD .. DRAIN FIELD · SEEPAGE PIT ALSO CONSIDER AREA WELLS. WATER MAiN TO SEPTIC TANK DRAIN FIELD SEPTIC TANK. /~0 , SEEPAGE PiT TO RIVER. LAKE, STREAM. SEEPAGE PIT /~O ! DRAIN FIELD CAST lEON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL~ 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. DIAGRAM OF SYSTEM ========================================== [ CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREAJ~OROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. /~~ /,/~ q-irt- DATE APPLICANT'S SIGNATURE/ FORM NO. EQ-016 4040 "B" STREET,' ANCHORAGE, ALASKA 99503 PHONE: 907.279.2581 September 18, 1975 W.O. #17517 Mr. Steve Ellis SECO Construction Star Route A - Box 36E Anchorage, Alaska 99507 RE: Subsurface Investigation for On-site Sewer Lot 4, Random Heights Subdivision Dear Mr. Ellis: As requested, we conducted a subsurface exploration on the above lot to determine the soils' suitability, as required by the Greater Anchorage Area Borough, for placement of an on-site sewage system. The exploration was conducted on Tuesday, September 9, 1975, utili- zing a track mounted, Mobile Drill B-50 drill rig, owned and oper- ated by Denali Drilling, Inc. The drilling was supervised and the testhole logged by Mr. Pete Herstek, staff technician with Alaska Testlab. The testhole was located approximately 40 feet south and 80 feet east of the northwest corner of the lot. Its log is included on Table A. To help interpret the information contained on the log, we have included three sheets of "Standard Explanatory Information" in the back of this report. The hole was filled with water and left to saturate. On Tuesday, September 16, 1975, water was again placed in the hole, to within 3.0 feet of the surface. For 60 minutes the rate at which the water level fell in the hole was recorded at 10 minute intervals. At the end of an hour the water level in the hole was at a depth of 6.4 feet, which is a total drop of 40", in 60. minutes, for a per- colation rate of 1.5 minutes per inch. Utilizing the data published in Table A "Absorption Area Requirement for Individual Residences", on page 8, of the "Manual of Septic Tank Practice" published by the U.S. Department of Health, Education ~ Welfare, the required absorp- tion area per bedroom for such a percolation ra~e is 80 square feet per bedroom. No water table was detected at the time of exploration. It should be noted, though, that seasonal and climatic changes can cause fluctuations in the water table. We hope this is sufficient for your present needs. If we can be of further service, please do not hesitate to contact'us. Very sincerely yours, ALASKA TEST_LAB · -Me~vin R. Nichols, C.E. Lot 4 Depth in Feet .From To 0.0' 1.5' 1.5' 4.0' 4.0' 16~0' Bottom of Test Hole: Frost Line: Free Water Level: TABLE A W.Oo #17517 Soil Description F--4, brown, organic overburden F-2, brown, silty gravelly sand, SM, ~wet, medium density F-2, brown, silty ~rave~l¥ sand, SM, ..dry to damp, medium density 16.0' None Observed None Observed WELL LOG Material Type Bottom dlom. __ ff. DeDth 9 FINISH OF WELL: Above or Well NO CONTRACTOR'S CERTtFICATI)N: ~ ~ MUNICIPALITY OF ANCHORAGE · . , DEPT. OF I-ff:ALTH & ~ ENVIRONMENTAL PROTECTION Well Log .~ ? ~o~ .......... ,~:~ ...... ~.....~...,..~ ...... ~.__,....~ ........................ R.~.C.EI.V.~D ]Date completed ...... .~..~~....~..../../..~...../~...~ ............................................. Size of casing.~: ........ .,W~z~..~..~.... ................................................................ Distance to water while pumping .:.-,~4'......~/':~.~...~~J~-- r~te of....~....~.~.~.~.~.....~.=..gallons per hour. Driller DELTA DRILLING COMPANY SRA BOX 394 B ANCHORAGE, ALASKA 99507 Depar. tmer~t. (::~' Health & Human Services 825 L. S'L r'.ee'L ~, Ar'H:::hcsr age, A ].~aska 9950 ! 0 N ..... S 2[ T' E W E L,. t .... P E R M I T' Da'Lc issued: L~:],/].5/89 Own ep Name .'-.' T i1'. M LYN[.;H Owner'. r..,~.,. ,.'Ir ~.,.ss. PO B[]X 11()496 ~.~I,,,H ,,tl ~,. [, h:, ~ AK Day :". 4 5 - Lo'i:, l....ega t ': Sub d :i. v i s :i. on: RANDOM HIE I GH"FS L..o'L ~ 4 B '.t. oc k: .... Lot ~;;i,:;~e 46747 (sq,, {'t,, or' acr'es) Max Bedr'.ooms~ Th:i.s Per'mit: () To'Lal Capac:i.t.y~ 4. WE]..,,I....: ' ' . ~,..,..,,g must be subm :i, tted 'L o Mun :i, (::: [ ~,'~'~ I i 'L y o { Anchor ac e D~,:.;p ar 'L men'L (::~ f Plea 1 'L h ....... ~ ~ ices with:i.n ::!!;() days of wel :t. comp let ion,, INSTALL. PIER DR:[I...,LERS SI'TIE F'LAN,, GROU'f'IN['!} t"I;.~Y BE: NIECIES!~;~ARY IF BIE;[)F:;:OCK IS ENCOUNTERED AT L..ESS THAN NOTE: N:["fRA'T'ES ARE F'RESENT tN 'H'"tIS At:RtEA, A WATER SAMF::'L,E SHOULD BE (:]BTAIIxlED 'T'O VARIF::'Y 'f'HE (];OI\I[]ENTRA"IH}.'OI\I F:'OR T'I.,.IIS tAIEL, t CIERt"IF'Y 'T'HA]: I a¢~] ,zalfl:J.].:i. ai" wi'Lb 1:.he requiremen'Ls ~oi" orr,,.site sewer's and wells a~i~ set for'1'J-~ by the Idur~:i. cipal:i, ty o¢ Ancl"u:)rage (MOA) ar'id the State oF Alaska,, I w:i,].l install the system :i,n a(:::cor'dar'ice w~,t,h all MOA codes arid r'egu:[at and :Ln comp],iance w~.t.h the dcs:i, gn c:r'it',,et":i,a of th:i.s pel'mit. I w:i, tl a(::ll"tel"e ~,(::~ all MOA arid State of Alaska r'equ:i, refi~er'rLs {'of the set back s~,.;,~wsrag6~ syst, sfli ol"i 'Lh:J.!!~i Qr' ar]y acl.jaE;er'rt or' r'H.:earl:)y lc)t,, also ur'icier'stand 'Lha'L the capac:i, ty (::)~ the 'Lot. al :~;y!~'l:,em :is 4 bedr'ocm'Hs and (J:]Wf'iE'P) T'IM I,.,,YNCH 12401, /, 2/ 12,4.35 SUB. 12500 12515 12720 LOFT)' lA 2A SUB. TOILSOME 12601 / HILL SUB, 12570 HEI~, TS 2 / SUB. :801 8601 8701 SPENDLOVE 8600 8?0O / 8 ?4O 8800 / 8801 DR. GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 Date Received November 8, 1976 Time of Inspection ~'~ Date of Inspection REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR Cony. l. Approval requested by: Alaska Mutual Savings Bank Mailing Address: Post Office Box 1120 2. Property 0wner: Timothy Lynch Mailing Address: NHN Ginami Street Phone: 274-3561 Phone: 276-3222 3. Legal Description: Lot 4 Random Heights Subdivision 4. Location: 5. Type of facility to be inspected Single Family 6. Well Data: A. Type Individual C. Construction 7. Sewage Disposal System: A. Installed C. Septic Tank: 1. Size D. Seepage Pit: 1. Absorption Area E. Disposal Field: Total length of lines 8. Distances: No. of bedrooms B. Depth 130' D. Bacterial Analysis On-site system B. Installer 2. Manufacturer A. Well to: Septic tank Nearest lot line B. Foundation to septic tank C. Absorption area to nearest lot line , Absorption area , Other contamination 2. Material , Sewer Lines ., , Absorption area EQ-034 (1/74) PaQe 1 of two DaQes Page 2 of two pages - Re¢-'st for Approval of Individual .~'~r & Water Facilities L'egal Description ]Sot 4 Random He±qhts Comments Approved~/F~~~) Disapproved Date//-~ App~val Valid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date EQ-034 (1/74) MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION NOV 0 8 1976 RECEIVED GREATER ANCHORAGE ARL,h BOROUGH Department of EnvirorJmental Quality 3330 "C" St.~ Anchorage, Alaska 99503 274~4561 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES Type of Inspection: CMRO VA FHA CONV ~ Property Owner: Mai 1 lng Address: ~__F~/~__~_Z~~/-- ..... _Da_y_P_~one _~6 ],~ ~,' Mailing Address: __~_~ZZZ]L~ _.D_a=% Phone Mailing Address: ~=~.J ~ ~_ _ 5. Name of R, ealtor or Agent: ~_~/~ Mailing Address: Phone Phone ~.L~2~.~_(~ / _ 7. Type of Facility to be inspected: 8. Nater Supply Type of Supply: Public Utility o No. Bdrms.__ Individual If Individual, number of dwellings presently served If Individual~ depth of well ~ ~ Sewage Disposal' System Type,of S~stem: Public Utility Individual (on-site))~