Municipality of Anchorage
On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 1
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP 221064
PID Number: 015 242 66
Dwelling: X Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New X Upgrade
Name
Marshall
ABSORPTION FIELD
❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound ..
Site Address
12161 GALENA
❑ Other
Phone
Number
of Bedrooms
Soil Rating
Total depth from original grade
3
GPD/SF
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Ft.
Gravel depth beneath pipe
Ft.
Subdivision Block Lot
JEM LOT 3
Fill added above original grade
Ft.
Gravel length
Ft.
Township Range
Section
Gravel width
Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
Ft2
Ft.
Well
+100
-
_
_
_
TANK X Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
GREER
Capacity
1000 Gal.
Surface Water
+100
_
_
Material
Number of compartments
Lot Line
+5
-
-
NA
POLY
2
Foundation
+10
_
_
LIFT STATION
Manufacturer
Capacity
Remarks TANK ONLY
-
_ Gal.
Alarm location
Electrical installed by
Installer
PIPE MATERIAL House to tank 3034Tank to 3034
drainfield
A PLUS
Drainfield CO/MT 3034
Inspector CHARLES BALZARINI
BENCH MARK (Assumed elevation) 100 ft
Inspdection 15` 3/28/22 2nd 3/28/22
Location and description
3rd 4th
GARAGE SLAB
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
4/1/22
�OFA/�II
Conditional Approval:
Date
'� • :qs l��
•
Septic System i
HARLES G BALZARINI j
rr
,s
Approved
Date L ' Z z
�0 . CE -13854
Note: this approval does not include well permit requirements.
•
1lilF�PRO4
FESSlONP
�I\GV VJ/VL/ IUB
.MTH
-�
•,
CHARLES G BALZARIM
��`c/•.
CE 1385411112 2
,•���®
i
/
/
100' WELL
/ / RADIUS
/
DRIVEWAY
EXISTING 500
GAL PUMP STATION
EXISTING DRAIWffLD / / NEW 1000GAL
POLY TANK k
/ G NEW DOUBLE CO'S 3 -BEDROOM
C BOTH SIDES OF TANK HOME
/
/ O
/ LEGEND
o CLEANOUT
10' UTILITY EASEMENT o MONITOR TUBE
® TEST HOLE
PLAN -SCALE: 1" = 30'
BM:+100.0' BOTTOM SIDING AT HOUSE
8.2' COVER
SEPTIC TANK
SCHEMATIC PROFILE NEW SHOWS ELEVATIONS OF INSPECTED
ELEMENTS BUT DOES NOT DEPICT SYSTEM IN ITS ENTIRETY.
INSPECTION FOR GENERAL CONFORMANCE TO DESIGN AND MOA
REQUIREMENTS ONLY.
SCHEMATIC ELEVATION - SCALE: NTS
LEGAL DESCRIPTION: JFM LOT 3
C&M ENGINEERING SERVICES OWNER: MARSHALL DATE: 4/1/22 1 REV: I DRAWN: CBJ REF:
907-854-5558
SEPTIC RECORD DRAWING
X00
.MTH
-�
•,
CHARLES G BALZARIM
��`c/•.
CE 1385411112 2
,•���®
i
/
/
100' WELL
/ / RADIUS
/
DRIVEWAY
EXISTING 500
GAL PUMP STATION
EXISTING DRAIWffLD / / NEW 1000GAL
POLY TANK k
/ G NEW DOUBLE CO'S 3 -BEDROOM
C BOTH SIDES OF TANK HOME
/
/ O
/ LEGEND
o CLEANOUT
10' UTILITY EASEMENT o MONITOR TUBE
® TEST HOLE
PLAN -SCALE: 1" = 30'
BM:+100.0' BOTTOM SIDING AT HOUSE
8.2' COVER
SEPTIC TANK
SCHEMATIC PROFILE NEW SHOWS ELEVATIONS OF INSPECTED
ELEMENTS BUT DOES NOT DEPICT SYSTEM IN ITS ENTIRETY.
INSPECTION FOR GENERAL CONFORMANCE TO DESIGN AND MOA
REQUIREMENTS ONLY.
SCHEMATIC ELEVATION - SCALE: NTS
LEGAL DESCRIPTION: JFM LOT 3
C&M ENGINEERING SERVICES OWNER: MARSHALL DATE: 4/1/22 1 REV: I DRAWN: CBJ REF:
907-854-5558
SEPTIC RECORD DRAWING
GALENA CIRCLE
w I EXISTING DRAIt�tPIELD /
c�a
w ( /
N /
N
w
z / (�
{ I
EXISTING DRAINFIELD
100' WELL
RADIUS
DRIVEWAY
nNG 500
PUMP STATION
a�NEW DOUBLE CO'S
BOTH SIDES OF TANK
I
49 TH
N• . CHARLES G BALZARII
CE -13854 .•��`��®
ROFESSI�NP�
3—BEDROOM
HOME I \
EXISTING WELL
�- REPLACE EXISTING TANK �J
_ WITH NEW 1000 GAL (MIN)
10' UTILITY EASEMENT —HDPE GREER TANK
SEE SITEPLAN FOR DETAILS
SCALE: 1" = 50'
C&M ENGINEERING SERVICES
907-854-5558
LEGAL DESCRIPTION: JEM LOT 3
OWNER: MARSHALL I DATE: 3/20/221 REV: I DRAWN: C131 REF:
AREA PLAN
00'006 M..00IPO.00S
O c
O
1N3W3St/3 '711/1 a `SS32�J3 `SS3LIJ/ \\\ E c � £ o F• -i f .,
--------------------------------— — ----------- f ----- -- -----------I
\ a) » c �01 a)
a o rxl QO\ niuZ0
E fl c Q O 6t
a)In0a a)
mLOw 03 @
x
�c» iz
:5 = a
Z,. 'it pn C) 2'w')iZ3a�mac Q
t so
•� n ' �aNo—�ae�
O 14 0'Z w LO �
CC >,
00 Z cn = a)O N N N �
j
/ i W In -0 O
m cu
NC C
,-L 2 d Q• o O
\ a
W o'st / t'ot \ s•se m a
\ _ N
Ucu — L
O C y .� w9 m N Ln
O a) N 3 W to O 41
N Ol
h' \ =
0- a) O nj O c0 EL/ I o N 9@ E'5 Y
�, N E
N E TN'C
O O O
O \ I p, ++ .0 N
�"- - N \\\\ M U x'06 N a) U Y V a1 N
\ a
a) N (6 O N O` N t0 OA al
I w
t CJ �N� �m ~a 2
£'OMr- OC O
> i taTa0 Q
U- O Na)3c2
� a
O oC V VQ�Qc�vL
E
kD a)
LU 0
N 56 co ac �ya�ia) * ja
Z c `� 3 `o a E -c v, a) Q `n � v
as a V , =
cV "E 4a I p C� ya)ymc Ln v� v Oi
N sty 38.30 PAVEp.p.RIVEWAY '� v c v N & E a� m T= L Q L
Y V N .0 pQ «. a) E Ql a1 V L N
�+ O O O O w w C U L OA �_ 00.(v
v c_ as o 3 N ra cn
p �� I L L mco wawa tn—� �` ° i 00-1�
O rn I Q a a m�_ �N°,�� In a Ingo
a) I o Z� me c"i N o H i-' a o LO o0 3
J Ln (' A LL, E �a I ® X31 4) 5n � F� eOu w Q = LL w (n
c U rn LO @
J T o��
-i Fn I nwn�
(/) r, 0 00
cu w LOU I Y Q
N
o. -�jN� oQ I m v oma= 0
CY �. = zo CL
v n_ w n n A
N "O N U N s „) Q. n w o a)
ai
L�- 0 -------------------------------- —) d rn2 a• � I N•z z
E9 'Od 69t 'ala = N ° u.: �; : o ® g
1N3W3St/3'7l1l1'8 `ssave3 `SS3&E)N1.9t v m y m 0 �� : � J o' `y w
370N/D VN3-7 3 - v D°_° o • o w
o so >yez M..os,00 noon► � v .E o o y •. O) . a z .•
I I W N a0 F
1 v N N N E s•' •fy
�N3lry,3'I b' w w v) a) t x — —
`'�O��o� 0301A1(7GnSN�) v <W ��, w a a •��
(V ch V'
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP221064
Work Type: SepticTank Upgrade
Tax Code Number: 01524266000
Site Legal Address: JEM LT 3 G:2740
Site Mailing Address: 12161 GALENA CIR, Anchorage
Owner: MARSHALL ROBYN A
Design Engineer: C&M ENGINEERING SERVICES
This permit is for the construction of:
Effective Date:
Expiration Date
Lot Size in Sq Ft:
Total Bedrooms:
��»crlt
t)eputmu�r
3/25/2022
3/25/2023
51457
❑ Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: Date:
Issued By: � � ,�'� Date:
3 a5o��
3
MUHMP „ WTV OF HU--JORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section --f Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel 1. D. 015 242 66
Property owner(s) MARSHALL Day phone
Mailing address 12161 GALENA
Site address 12161 GALENA
Legal description (Sub'd., Block & Lot) JEM LOT 3
Legal description (Township, Range & Section)
Lot Size 51,457 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑
Initial ❑
Single Family (SF) ❑
(w/wo ADU)
Septic Tank
X
❑
Upgrade x
❑
Duplex (D) ❑
Holding Tank
❑
Renewal ❑
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
C&M ENGINEERING
(Signature of property owner or authorized agent)
Permit/Rush Fees: it 36 of Waiver Fees:
Date of Payment: 3/2 Date of Payment:
Receipt Number: 0 1 22 7 J Receipt Number:
Permit No. O's Pa a 10 (o C� Waiver No.
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc
C&M ENGINEERING SERVICES
Ph: 907-854-5558
Municipality of Anchorage
Onsite Water & Wastewater Program
4700 Elmore Rd Anchorage, Ak 99507
RE: Proposed Septic System for JEM Lot 3
Dear Reviewer,
The above referenced property is currently served by an older septic system with a leaking tank that
needs to be replaced.
The owner wishes to replace the tank at once.
Our review of available documentation and field investigation show that this project will not adversely
impact any nearby Wells, Wastewater disposal systems, replacement disposal sites, or drainage flowing
onto and off of the subject property.
As shown on the plan, the tank will be greater than 10’ from the house foundation.
The tank shall be covered with a minimum of 2” moa approved insulation and 3’ of cover or a minimum of
4’ of cover without insulation.
The repair must be performed by a moa certified installer in accordance with MOA requirements.
Repair of the proposed system will not negatively impact adjacent lots.
Upon completion of the installation, a record drawing will be submitted showing the location of the new
tank, leach field, well, and other applicable features.
Thank you for your time in reviewing this permit request. Please do not hesitate to contact me at 907-854-
5558 or by email cgbalzarini@gmail.com with any questions or concerns.
Sincerely,
Charles Balzarini, PE
3/20/22
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221064, Rebecca Carroll, 03/25/22
CHARLES G BALZARINI
CE-13854R
EGISTEREDPROFE S S IO N ALENGINEER3/20/22
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221064, Rebecca Carroll, 03/25/22
CHARLES G BALZARINI
CE-13854R
EGISTEREDPROFE S S IO N ALENGINEER3/20/22
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221064, Rebecca Carroll, 03/25/22
C)IvI-10Pment Services oepartj..j.
0 Building Safety bivisioll
On -Site Water A WQSftwater Pro
gram
7
4700 Elmore Rood
P.O. Box 196650
Mark Begich
<
Mayor Anchorage, AK 99507 S A E 7
www-muni.org/onsitp
(907) 343-7904
Well Drilling Permit Numbej% SW PUMP �nzftfla%on Log
Date of Issue.,
Parcel Identiricati.,
Legal Description /,0 7 3
Property C)wner Name & Addr , S! , �j
Ure
fft� L
L 3 12V�l C7 "e,,_ Ce e e
Pump Installation Date: <
�16
Pump Intake Depth Below Top of Well Casing: Z VO feet
Pump Manufacturer's Name:
Pump Model: Las U_p
Pump size S/Le bp
Pitless Adapter Burial Depth: i/Z— feet
Pitless Adapter Manufacturer's Name:
Pitless Adapter Installer:
Well Disinfected Upon Completion?
Method of Disinfection, esONO
COMMents: evl
-
Pump Installer Name:'ANCHORAGE WELL & PUMP SERV.
AN
TH
00* 330 EAST 76 AVENUE
ANCHORAGE, AK 99518
PHONE: 907-243-0740
AWPS Com
Attention: The Pump installer shall provide a pump installation log to the DSD within 30 days of pump installation'-
Municipality of Anchorage
Community Development Department Page 1 of 3
On -Site Water and Wastewater Program
4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP131425 PID Number: 015-242-66 ❑ New Upgrade
Name:
Michael and Cynthia Bradley
ABSORPTION FIELD
❑ Deep Trench ❑✓ Shallow Trench❑ Bed
Address
12161 Galena Circle Anchorage, AK 99507
;E]Mound
E]Other
Phone
Number of Bedrooms
Soil Rating
Total depthfrom origina
3
1.2GPD/SF
5Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Gravel depth beneath pipe
4.OFt.
Subdivision Block Lot
JEM 3
Fill added above original grade
2.5 Ft.
Gravel length
40 Ft.
Township Range Section
Gravel width
5Ft.
Beds: Number of Lines
Distance between lines
SEPARATION DISTANCES
Ft
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
400 Ftp
One
Ft.
Well
>100'
>100'
NIA
N/A
>25,
TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Existing
Capacity
Gal.
Surface Water
>100'
>100'
N/A
N/A
Material
Number of compartments
Lot Line
>5'
>10'
N/A
N/A
NA
Foundation
>5'
>10'
N/A
N/A
LIFT STATION
Manufacturer
city
Curtain Drain
None
Noted
Anchorage Tank/Orenco
500 Gal.
Remarks Existing Septic Tank Verified Suitable for
Pump on level at
38 in,
Pump off level at 4High
water alarm at
45in.
Continued Use. Existing Absorption Trench
Decommissioned in Accordance with Municipal Code
Pumpake and model
OSI P2005-11
Electrctions performed by
Munof Anchorage
Installer
PIPEMATERIAL Housetotank D3034 Tankto
drainfield D3034
John's Excavating
Drainfield HDPE Co/MT D3034
Inspector A. Harala
BENCH MARK (Assumed elevation) 100.Oft
Inspection
dates: 11/20/13 pia 11/20/13
Location and description
p
3r°11/21/13 4'"
Garage Slab.
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
• OF
gC�S�®
Conditional Approval: Date
1
r�'P��
jAww *: 49 TH
J'. CE -4381 'www
Approved®�®TSPD•sr
G[%, Date -A3/
:y ••L�q`V
9�;`
"�`:�'
Inmcrfinn Rcn 1_i» n....
RC1 -imp a
m
z
� y � CJ
o
:.
O N y Q O
O
0
O
0 0 0 4
W
mc 0 y
O N
234.09' N00° 00' 50•E
A
�
o ! \\
15' INGRESS,
EGRESS & UTIL
ESMT
.....
............................................
a
'I
t
\+
o ao 0
Fry O O T ~
N
•\
''i
3xno➢
P
om
m �
' i\
y
'•.i
4E s
A
00
�o
al_.
Du I n
S3'
\4
yytlL
N< 9
z
.i
w 9
O
y tO r I
+i+
^
n N
O N I
ii+
m
N W m
m ``�
VJ
O
o W
o y w D
, fit 3m M
zCi
y d
N _
N
C
N+ W N C m
w M
(n m Co
pnp
�
K
m cmo
8
0
o oo
o�j
o
O
o
0<< � m
no's
m OD'.
C(O ftp
3
o pp
CD
N
y CP M
m
�wm
o
ti A Z
®n__'"
O
tip
A
T
'O
0
................................................................
151 INGRESS,
EGRESS & UTIL ESMT
O
S00° 04' 00"W
100.00'
Z
o
�
om
:?jI
. � �• /
aim.
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 South 6ragaw Street Anchorage, AK. 99519-6655 - 343-7904
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number: OSP131425
N
F—
F-11-351
Page 3 of 3
PID No. 015-242-66
� 93:8 90.8
N UU
Tank
Drainfield Rock
Groundwater@78.1 ��— 77.1
11-19-13
40'(Trench Length)
PROFILE AS -BUILT
No Scole
a�
1
83.1
.'• 49th
MICHAEL E. ANDERSON
No. :E si
87.1
On -Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP131425
Tax Code Number: 01524266000
Work Type: Septic
Permit Effective Dates: November 08, 2013 to November 08, 2014
Design Engineer: ANDERSON ENGINEERING
Subdivision: JEM
Site Legal Address: JEM LT 3 G:2740
Owner/Address: BRADLEY MICHAEL B & CYNTHIA E
12161 GALENA CIRCLE ANCHORAGE AK 995078042
Site Mailing Address: 12161 GALENA CIR, Anchorage
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank
111-4 0// --,!7
Lot Size in Sq Ft: 51457
Total Bedrooms: 3
N Privy N Private Well N Water Storage
2 /V^
7 ern
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Special Provisions:
1. The existing trench
submitted.
as a reserve site without a I f n o leco�6�tion — NIP - 'Too Qee� �
2. The Engineer needs to do an additional test hole prior to the construction of the septic field.
Construction may proceed at your own risk before the 7 day water monitoring is complete. Please
submit stamped and signed results with the As -built Inspection Report. If the results require a
design change, construction of the system will stop pending On -Site review and approval.
Received
Issued By
Id�9�3 GO f (roan wAttr hryh, 06vtjcA )?+k of-'renc.�
obeeti. /1cw peel r Fi
MUNICIPALITY OF
Community Development Department
Development Services Division 4
On -Site Water & Wastewater Program
ANCHORAGE
ON-SITE SEWER/WELL PERMIT APPLICA
Parcel I.D. 015-242-66
Phone: 907-343-7904
Fax: 907-343-7997
Property owner(s) Michael & Cynthia Bradley Day phone
Mailing address 12161 Galena Circle Anchorage, AK 99507
Site address Same
Legal description (Sub'd., Block & Lot) SEM, Lot 3
Legal description (Township, Range & Section)
Lot Size 51,457 Sq. Ft. Number of Bedrooms Three (3)
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(EI all that apply)
Absorption Field
0
Initial ❑
Single Family (SF)
0
(w/wo ADU)
Septic Tank
0
Upgrade 0
Duplex (D)
❑
Holding Tank
F1Renewal
F]Multiple
Dwellings
❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION
INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
Permit/Rush Fees:
Date of Payment:
Receipt Number: Oilb-1 C\
Permit No. O 5 pl ? 1 N
Permit App_9-1-12.doc
Fees:
Date of Payment:
Receipt Number:
Waiver No.
November 7, 2013
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 Elmore Road
Anchorage, AK 99519-6650
Subject: Lot 3, JEM Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The existing absorption trench on the subject lot has failed and must be replaced .prior
to the issuance of a Certificate of On Site System Approval (COSA). We are therefore
requesting a permit be issued for the upgrade of the septic system to accommodate the
three-bedroom home on the lot. The_ attached Site Plan and backup documentation
identify the location and configuration of the existing and proposed septic system. The
existing Septic Tank will be uncovered, inspected and verified suitable for continued
use. The existing absorption trench will be left intact and tied to the new system with a
flow diverter valve. Also identified on the plans are the locations of the existing well on
this and adjacent lots and adjacent septic systems. No conflicts exist between the
proposed septic system and the wells on this or adjacent lots. Protective radii are
shown to the adjacent wells. Drainage arrows are shown indicating the current
drainage patterns. The drainage patterns will be maintained after construction.
The test hole placed on the lot during the initial installation indicated Silty Sand to well
graded sand (SM/SW) to a depth of 18'. No groundwater was encountered and none
developed during the monitoring period. The percolation rate in the SM soil lense was
determined to be 4.4 and 2.2 minutes per inch in the SW lense. We have designed
the new trench with an application rate of 1.2 gallons per day per square foot. We are
proposing to place a 40' long by 5' wide absorption trench with a 4' effective depth. The
total depth of the system will be 7' with the distribution line at 3' below the existing
surface. A flow diverter valve will be placed to connect the existing trench to the system
for future use. The existing system appears to be in the electrical easement. We are
requesting the permit be issued for construction of the new trench while the
encroachment permit for the existing trench is ongoing. If we are unable to acquire the
Lot 3, JEM
August 18, 2013
Page Two
encroachment permit in a timely manner the existing trench will be abandoned in place
in accordance with Municipal Code.
The ground surface on the lot slopes to the northwest in the area of the absorption
trench. The trench will be placed parallel to the contours of the ground as much as
possible and in conformance with design criteria. A minimum of 100' will be maintained
between all components of the septic system and the proposed well and from any
surface water in the area.
If the system is constructed in accordance with our design the following statements
apply:
1. The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
%y�,��-,
Michael E. Anderson, P.E.
Attachments
49th
MICHAEL E. ANDERSON
Municipality of Anchorage Page of�
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: -IVY/ 4ti7o23Z PID Number: 016-0-41— tab
Name: C-Y (2&rqST0_0GT%0tA
Wastewater System: ElNew 1:1Upgrade
Address:
ABSORPTION FIELD
Phone:
3 - �d
No. of Bedrooms:
3
p Deep Trench i Shallow Trench ❑ Bed ❑ Mound ❑ Other
LEGAL DESCRIPTION
Soil Racing:
Total Depth from original grade:
a C� GPD/Sq. Ft.
Lot: Block: Subdivision:
Depth to pipe bottom from ori coal grade:
Gravel depth beneath pipe
' Ft.
Ft.
Township:Range:
g
��/�
Section:./� 1�
Fill added above original grade:
/0
Gravel length:
i 2
3 lXi
v /
Ft.
Ft.
WELL: New El Upgrade
Gravel depth^ Lii+'a%/�j
Nu mber ofp9lines:
I
Distance between lines:
'
Ft.
Ft.
Classification (Private, A,B,C):
Total Depth:
Cased To:
Total absorption area:
Pipe material:
Ft.
3 Ft.
nry
/ SQ. Ft.
3�'S Z r /-: k 10
Driller:J/��
Date Drilled:
Static Water Level:
Installer:
Date instal ed:
_
A L-P iL
Ft.
�
b ''i q
Yield:
I Pump Set at:
I
Casing Height Above Ground:
TANK
GPM
-2 & Ft.
a Ft.
SEPARATION DISTANCES
Septic ❑ Holding ❑ S.T.E.P.
To
Septic
Absorption
Lift
Holding
Public/Private
Manufacturer:
�,aL �? E
Capacity in gallons:
I
From
Tank
Field
Station
Tank
Sewer Lines
".)'-0
J
Material: v j �J
�(�
Number of Compartments:
Well
t 37
`
6 —(
1
c/XI,
SurfaceN�A
Water
LIFT STATION
Lot
i'
Size in gallons:
Manufacturer:
Line
Y5
"Pump on" level at:"Pump
off' level at:
High water alarm at:
Foundation
7A
Curtain�j
fT J
Pump Make & Model
Electrical Inspections performed by:
Drain
BENCH MARK
Remarks:
Location and Description:
p V Lt
Assumed Elevation: 116-1
Ft.
ENGINEER'S SEAL
1
Dates: 4►
Inspections performed by:
8131
2nd a
Department of Healtb and Human Services approval
Reviewed and approved by: Date: 2 - Z9- /
72-013 (1/91) MOA 25
N
C)
D
r
M
N
0
O r: ES
�i at 0 p00�O /
is u o;
c
m �a
of n� /
O
\ / N 00'00'50"E 234.09'
— 15' INGRESS, EGRESS,
\\ ------ & UTIL_ESMT_--- D
— — — — — — — — — — — — n n Z r
—�--[--- n$�o m
\ r
Z
�o-� II
D
or -
mo
r \ L O
Ln --1 \\ a00
n o g �o N. .Z7
n mn °oo.
D O
G):�E A� \ \\ A \\ 4` 5
2 \ \ o
h 0
'§
52 I✓
70-
� o \
^w' I n \ \ N r (n
LA 00
V O� N�CA T G N
0
SoA \ O
D \
\\ m Sx o \\ Z
zI non a m
0 � Na 11.
� a9 o n II
I I I .�nw p'S Z
I ! �
111 I 111 / o c I
I /
INGRESS, EGRESS,
\\ I & UTIL. ESMf.
\\ N 0904'00"E 100. 0' i i
C) -,2,t-
LOT 3, JEM SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Three Bedroom Home 5' Wide Trench System
Perc. Rate: 1 - 5 Min./Inch Verify Existing 1,000 Gallon Septic Tank
Application Rate: 1.2 GPD/SF 4' Drainfield Rock
500 Gallon Add On Lift Station
3 Bedrooms * 150 GPD/Bedroom = 450 SF Absor tion Area
450 SF/1.2 GPD/SF/5 SF (Width) *.5 (Red. Factor= 37.5 LF Trench Length
THEREFORE: Construct a 40' Long x 5' Wide x 4' Effective Depth Absorption Trench.
Flow Line Elevation in Trench to be 1' Below Original Ground Surface. Total Depth to be
5' Below Existing Ground. Provide 3' Cover Over Absorption Trench and 4' Cover Over
Septic Tank.
Natural Backfill
61 1 \O
4'
5'
Geotextile Fabric
1" Perforated
PVC (Holes Down)
30-5/16" Diameter Holes
@ 1.3' Spacing
Drainfield Rock
TYPICAL 5' WIDE TRENCH SECTION �,,.•oF"'o
(NO SCALE) .............. q,
NOTE: Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock. ........ 49th
Minimum 4' Separation From Groundwater. 011
Minimum 100' Separation From Private Wells in the Area. MICHAEL E. ANDERSON
Minimum 100' Separation From Surface Water or Streams. ��� ; No. CE.4381
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
4700 BRAGAW STREET ANCHORAGE, AK 99519-6650
DEPTH
(feet)
1 -
2
3
4-
5-
6-
7-
8-
9-
10-
11
15
16
17
18
19
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: LOT 3, JEM SUBDIVISION
PERFORMED FOR: NATHAN SMITH
DATE: 11/14/2013 PROJECT No.:
PARCEL ID#: TECHNICIAN: M. ANDERSON
TEST HOLE A
JUM OB/OG
d SILTY SAND
a WITH GRAVEL
a SM
d
SLOPE
WAS GROUND WATER ENCOUNTERED? YES
IF YES @ 0'
DEPTH OF WATER AFTER MO
BOH @ II' DATEOFMO
49th.•°:
MICHAEL E. ANDERSON
Pm&wi... I
SITE PLAN
SEE SITE PLAN
2
s
WHAT DEPTH? --
NITORING: 10' 0
DATE READING
MTORWG: IV 19/2013 p
'Cr GROSS TIME NET TIME -DEPTH TO NET DROP
(MINUTES) (MINUTES) WATER _(INCHES)
(INCHES)
PERCOLATION RATE (MIN/INCH) PERC. HOLE DIA.T(INCHES)
TEST RUN BETWEEN: FT. and FT.
COMMENTS: TEST HOLE PRE HOLE TO DETERMINE GROUNDWATER LEVEL. ORGANIC MATERIAL TO 1'. GRADING HAS BEEN
COMPLETED ON THE LOT SINCE THE SPUR_KLAND_TEST HOLE WAS PLACED REDUCING THE DEPTH OF THE. ORGANIC LAYER.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 11/19/2013
PERCOLATION RATE (MIN/INCH) PERC. HOLE DIA.T(INCHES)
TEST RUN BETWEEN: FT. and FT.
COMMENTS: TEST HOLE PRE HOLE TO DETERMINE GROUNDWATER LEVEL. ORGANIC MATERIAL TO 1'. GRADING HAS BEEN
COMPLETED ON THE LOT SINCE THE SPUR_KLAND_TEST HOLE WAS PLACED REDUCING THE DEPTH OF THE. ORGANIC LAYER.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 11/19/2013
Clean Out
.s
1
Wide Trench: 5' Wide
80' L ong
4' Deep O GWM
2' Sewer rock
3' Cover
I
Mirafi 140
2 Feet of Septic
Double Clean Outs
1000 gal Septic tank
Foundation Clean out
,+-
9
71.
99.3
TOBBEN SPURKLAND P.E.
LOT 3 JEW SUBDIVISION
SEPTIC
SYSTEM ASBUILT
203 W15th Ave
SECTION 24 T12N R36/
DATE-
DEC, 1Q 1991
Anchorage Ak 99501
CAMEL CONSTRUCTION
SHEET:
313 GRID, 2740
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW910237
DESIGN ENGINEER:TOBBEN SPURKLAND, P.E.
OWNER NAME:GAMEL CONSTRUCTION
OWNER ADDRESS:P. 0. BOX 2965
ANCHORAGE, ALASKA
PARCEL ID:01524266
LEGAL DESCRIPTION: JEM LT 3
LOT SIZE: 51457 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
PAGE 1 OF 1
DATE ISSUED: 8/14/91
EXPIRATION DATE: 8/14/92
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
1.
2.
PROVIDE SOIL TEST DURING CONSTRUCTION WHICH VERIFIES
SOIL CONDITIONS AT SOUTH END OF ORIGINAL AND REPLACE-
MENT TRENCHES.
TOTAL DEPTH OF SYSTEM MAY NOT EXCEED 4.0 FEET.
RECEIVED BY:
ISSUED BY
4t cu� (yam-[ _t_
DATE:. f
DATE: `� v
20N151h.AvoueSude206
ANCH8AGE�ALASKA��N
(9�D279~39�6
SEP T I C SY STEM DES I GN REVISIED 0/13/91
-4�� - B D ,� �t� � �
GAMEL CONSTRUCTION uBujnHg
166~`^���
�� �v^�
Re;uired Area per Bedroom:
15O/.8 � 187.5 sq.ft..
Number of
Bedrooms
of this
��
� ���
Ground Water
at 9 ft,
Soil test
July 24/� ,~� ^�����
Use Wide
Trench
Reduce Area
by Using
24"
of
Rocks
Reduction
Soil Rating.
From
test July 9,
1991
Length of
4.4
min/in � 1.2
gal/min
.7/5 = 78.75
Use
.8 gal/min
lots
Re;uired Area per Bedroom:
15O/.8 � 187.5 sq.ft..
Number of
Bedrooms
of this
well
3
Required
Absorption
Area:
562.5
sq.ft,
Reduce Area
by Using
24"
of
Rocks
Reduction
Factor:
.7
the area�
and
Length of
Trench
562.5
x
.7/5 = 78.75
USE 80 FT.
these
lots
c-,
replacing the existing
SYSTI=M comVisuRA710M
5 FT . IWI DE TRENCH
TOTAL LENGTH
TOTAL WIDT"
TOTAL DEPTH
ROCK DEPTH
COVER/ F !Ll—
SEPTIC TANK
80 FT
1000 SAL.
The
installation
of this
well
and
tic
system will not
impact
adjacont
lots.
The well
location
conforms
to the sit�ng
of the
existing
wells in
the area�
and
will
not
prevent the adjacent
lot
owners
from developing
these
lots
c-,
replacing the existing
septJc
systems.
The
installation
of this
septic
system
will not prevent
wells
from
be installed
on the
adjacent
lots.
Septic System Design
Lot 3 JEM
pg.1
�ourses on this or the adjacent lots.
,
The proposed septic system will not change the general slope of
the area. Ponding and/or concentration of surface runoff will not
result from this installation.
Septic System Design
Lot 3 JEM
pg.2
TO BE PERFORMED DURING
CONSTRUCTION
p5 0 PS 50 75 100 IPS 150
SCALE. 1'' = 50 FT,
TOBBEN SPURKLAND P.E. L17T 3 JEM SSD SEPTIC SYSTEM DESIGN
203 W 15th, Avenue SECTION P4 T1PN R3W DATE' JULY 30, 1991
Anch, Ak. 99501 11 cnucr rnetcFOrlrTTnM TMC SHEET, 1/3 GRID- 2740
516�p
Clean Out
Wide Trench -
Monitor
Clean Ou
S' Wide S
80' L ong
4' Deep
2' Sewer rock
3' Cover RECEIVED
War; 140
2 feet o / Sep tic I.
Double Clean Outs AUG 13 1991
Municipality of Anchprage
Dept. Health S Human Services
1000 gal Septic tank
Foundation Clean out
rl,,,. .-, ,+,
3und
TUBBEN SPURKLAND P.E,I I L17T 3 JEM SUBDIVISION I I SEPTIC SYSTEM DESIGN I
203 W15th Ave SECTION 24 WN RWDATE- AUG, 7, 1991
Anchorage Ak 99501 CAMEL CONSTRUCTION SHEET, 3/3 GRID: 2740
6a7)
ALA TNA A VE,
I S
T
car 1
zl
,`.
LOT 2
\7
%\
LDT 3
(V \ -0- Vall
o
�7
V
50 0 50 100 150 1I200 250 300
SCALE` 1' = 100 Fi
�'2 LfE; fIJAVGB-3Vfwe4f
P'� 06s�C .BCCw G •OG31! 9
;ham•.nir oral
y�,, •b , CE•_2zb �_
LDT I
LOT 2
LOT 3
Q
LDT 4
TOBBEN SPURKLAND P.E. LOT 3 JEM SSDII
SEPTIC SYSTEM DESIGN
203 W 15th. Avenue DATE, JULY 30, 1991
Anch. 99501 SECTION P4 T1PN R3W
enuei rneicrelirrmu Feu^ SHEET. //,Q GRIDS 2740
a
25 0 25 50 75 100 125 150
SCALE., I' = 50 FT.
TOBBEN SPURKLAND P.E.SEPTIC SYSTEM DESIGN
203 W 15th. Avenue LOT 3 JEM SIT
Anch, Ak. 99501 SECTION 24 T12N R3W DATE: JULY 30, 1991
ramri cnucrailmnAl nvr SHEET3 GRID, 2740
J'
�G
rya
� Tr
-'a
c arse
C.E-'% J1.J
TOBBEN SPURKLAND P.E.SEPTIC SYSTEM DESIGN
203 W 15th. Avenue LOT 3 JEM SIT
Anch, Ak. 99501 SECTION 24 T12N R3W DATE: JULY 30, 1991
ramri cnucrailmnAl nvr SHEET3 GRID, 2740
Clean Out
Stanclo
Mira fl 140
5 Feet o F Septic Rock
Cleanouts
Monitor
4' Topsoil
4' Co ver
Exist, Ground
4' Min
ank
I IUbbLN JYUKKLHND F',t. II LOT 3 JEM SUBDIVISION II SEPTIC SYSTEM DESIGN I
Anchorage
Ak 99501 Ave SECTION 24 T12N R3W DATE: AUG, 7, 1991
Anc
?7q_gqlr CAMEL CONSTRUCTION SHEET, 313 GRID, 2740
(ENGINEER'S SEAL)
Municipality of Anchorage j
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
.o
PERFORMED FOR: A L OM S T120 c.Ti i D tom} DATE PERFORMED: _748li 1_` L COM
LEGAL DESCRIPTION: LOT '6 Township, Range, Section: -Cla r,1 ,Z LVL
pe!P , SLOPE SITE PLAN
(F ET Or�awies £ -
1 / I.00.vt4f avpurvf
N
2
3 alp Si l-�
Sa.K
4-. � L•GvkS�S •eu,..�
5-'
` • S�-�.�cQ
6
COMMENTS
Net
Drop
ENCOUNTERED?
7
,
s
8
.'
DEPTH?
9-
E
10
10-
7
Monitoring? D:" Date:
11
11
CJ
12
3
13-
14-
14151617
15-
16-
17
.
8
18-
1920
19-
20-
COMMENTS
WAS GROUND WATER
Net
Drop
ENCOUNTERED?
s
IF YES, AT WHAT
L
O
DEPTH?
P
E
Depth to Water After
7
Monitoring? D:" Date:
U
Reading Date Gross Net Depth to
Time Time Water
Net
Drop
PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN FT AND FT
PERFORMED BY: I CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 4/85)
T -T r I_. V�' t.- .
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES +
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
_� A H G �,,., (0 0 ST ►`V C 1 0 q DATE PERFORMED: �+ q �-1`I Jf
PERFORMED FOR: ,�, .
LEGAL DESCRIPTION: Lo T 3 F M Township, Range, Section: -'( At -1 { 2 7J w/ s G c a q
-f SLOPE SITE PLAN
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
Depth to Water After
Monitoring? Date:
S
L
O
P
E
Reading Date Gross
Time
Net
Time
Depth to
Water
Net
Drop
43 : I
10
1 t4 '18 10z'
3:2 q
10
Iq Vil 19'ls
3t Bel
o
14 74/19'
c qq
10
Iq It
a 5
ro
y/ I
rd'y
:a q
In
ivy&
'
20
PERCOLATION RATE �• � (minutes/inch) PERC HOLE DIAMETER �✓
TEST RUN BETWEEN FT AND FT
COMMENTS
PERFORMED BY: • S 1 CERTIFY HAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: tt i� -` R/
72-008 (Rev. 4/85)
1 (ENGINEER'S SEAL)`
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: G/' HEL CON st 22UCXt0tN DATE PERFORMED: -7/9�aL;-'i
LEGAL DESCRIPTION: L.o 1 3 M Township, Range, Section: �-��, Nr 12.3 Uij �w'�• C.c2y
DEPTH SLOPE SITE PLAN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
WAS GROUND WATER
ENCOUNTERED?
S
IF YES, AT WHAT L
O
DEPTH? P
E
Depth to Water After
Monitoring? Date:
Reading Date Gross
Time
Net
Time
Depth to
Water
Net
Drop
q 9 S; 12.
--
o20'i
3: 27.
1 O
Isys -
8
2
10
a1
361Z
10
cai
6.4.
IO
r �L
'b s.
lv
Is % •goNJ/
•'l,2
I t7
'
�
PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER
6
TEST RUN BETWEEN FT AND 2-L FT
COMMENTS C )�+
PERFORMED BY: ✓ I Y CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 4/85)
Ir ii IF
1. 1 l:7.
I J� JL I . .. .....
2 03 '1151 L
v Rin tt e -.u4 I - 9 0 L
, , L� , .
PINCHIRA'61c
kh,'Sfl,� 5150!.
i _7T7
27 3 - -ID 14.
SEPTIC SYSTEM DESIGN
9 M. 12pw a
0 -m- - SUBDT_Vls�om
GAMEL CONSTRUCTION
h:'- N-�
'I
.... . ... . ..
f _1 v a CA e F:;, o c.: 'L:: r
ZI
c)"i: DI.N-li (R ---!f'--:.;
Sli Y z-31 e E M C 0- M F I C– P, tp —a T 0
STANDARD TRENCH
TOTAL LENGTH
TOTAL WIDTH
TOTAL DEPTH
ROCK DEPTH
COVER
SEPTIC TANK
v s.' :�n
I. c'
60 FT.
1000GAL_
The installation
of this
well
and septic
impact
system
will not
adjacent lots. The
well
location
conforms
to the
siting
of the
existing wells in
the area; and
will
not
prevent
the adjacent
lot
owners from developing
these
lots
or
replacing
the existing
septic systems.
Thnstallation
of this
septic
system
will not
prevent
wells
from be installed
on the
adjacent
lots.
There are no developed
or
natural
surface
/ sub surface
drainage
courses on this or
the adjacent
lots.
The proposed septic system will not change the general slope of
the area. Ponding and/or concentration of surface runoff will not
result from this installation.
Septic System Design
Lot 3 JEM
V ~ oil Ww. RHATA V,. W�~
2C3N15th.Avenuo:Suit»2H
4NCH0KAGE`ALASKA995N
27Y -3Y|6
SPECIFICATIONS FOR SEPTIC ;SYSI-Ell INSTALLATION
1.0 GENERAL
1.1 Owner- is Gamel
Construction, P^O^ Box 2965
Anchorage;
Alaska 99523, Phone
349~4920
1.2 Engineer is the
person or entity hired
by the
Owner to
inspect this project,
The EnQUneer must
be recognized
by the
Municipality of Anchorage,
Department of Health
and Human
Services.
1.3 Contractor is
the person or entity
hired by
t1 Qwner
to install this project.
The Comtractor
must be
recognized
by the Municipality
of Anchore" Department
of Health
and
Human Services.
1.4 The Drawi11gs9 sheets 1 through 3� shall be part of this
specification.
1.5 All materials and workmanship shall meet the require�
ments of tho Municipality of Anchorage, Department of Health
and Human Services` the conditions of the permit, and all
applicable rules and regulations currently in effect.
1.6 All excavation depths are advisory�I and are to be
verified and may be modified in the field by the Engimeer-
1 lu
he responsibility of the Owner or the Contractor
to adhere to the approved design, to verify that the s!.-;eci-
fied separation distances are met, and that the required
inspections are performed"
1.8 The Contractor or the Qwmer shall report to the Engi`
Flee]- any observed condition which would put the septic
system in violation of State or Municipal regulations.
2.0 SEPTIC TANK
2.1 If there is an existing septic tank, J.t may be used if
�t meets the capacity reguirement for the residence. The
tank shall be inspected by the Enq i rwerand its water
tightness and structural integrity shall be vorifinod .
2.2 A tank shall be one fabricated by either
Spycificat ions for septic system installation
Lot 3 JEM Subdivision
The
septic tank
shall be a UPC�approved
two~compartment
absorption field shall
tank.;
constructed
of 12 gauge; or better;
steel with bitu
mastic
coating,
The tank shall be set level
on undisturbed
screened
soil.The
tank
shall be covored with the equivalent
of four
the No. 200
feet
of soil.
to a solid section
of pipe.
2.3
The septic
tank shall be installed a
minimum of five
3.6 GeotFox tile
feet
from the
house foundation and a minimum
of five
Is
from
the absorption
area.
irig or
for filtering;
2.4The
septir
tank shall be a minimum of
J. feet from
any
well
serving
OR single residencz; 100 feet
from any body
of
water,
creeks
or drainage ditches with flowing
water;
150
feetfrom
Class
"C" wells, and 200 feet
from Class A
or
Class
B wells.
3.3
4~inch
perforated
2.5 All pipe connections to
watertight calder couplings.
as designated ;And capped with
outs shall extend a minimum of
elevation. ProvisionV; shall
importation if topsoil.
the tank shall be mechanical
Cleanouts shall be installed
air—tight rain caps. Clean -
12 inches above final ground
be made for landscaping and
3.1
Gravel
in
the
absorption field shall
be 0.5 to 2.5
pipe penetrating
used
shall be fluorfo-,
rated, either
by dr:illing
inch
screened
rock,
with
less than
M. passing
the No. 200
p�le
to a solid section
of pipe.
sieve.
3.6 GeotFox tile
shall be
Mirafi
140,
3.2
Sand,
used for
lcovey!
irig or
for filtering;
shall have an
effective
grain
size
between
No.
40 sieve
and No. 18 sieve.
Uniformity
coefficient
shall be
less than
it. Not more th;in
5% by
weight
shall
pass
the No.
20O sieve.
3.3
4~inch
perforated
pipe shall
be ASTM
F810. For IDV- es~
sure
distribution,
pipe
shall be
Schedule
111) PVC or ABS.
3.4 Sulid 4 -inch pipe shall be Cast Iron or ASTM D3034.
3.5 Monitor
standpipes
shall
be installed
as shown. That
section of the
pipe penetrating
the
shall be fluorfo-,
rated, either
by dr:illing
0.5/'
holes on
6~i1
1ch centers or by
joining a section
of F810
perforated
p�le
to a solid section
of pipe.
3.6 GeotFox tile
shall be
Mirafi
140,
3.7 Insulation shall be extruded direct burial polystyrene.
Dow Chemical Styrufoam HI W.
3.8 Topsoil shall 6e a fir 1xture of 40-60% organic matter�
20~3O% sand and more that 20% silt. All quantitics are
moasured by volume.
`
Specifications for septic system installation
Lot 3 AM Subdivision
pg"2
3.9 Grass seed shall be Kentucky bluegrass"
4.0 INSTALLATIQW
4.1 Locate
all underground utilities, property
lines,
level and scarificod ^ If sidewalls smears, they
shall also
be scarified. Record elevation of beginnin�,
middle and
end of Record elevation of each corner
future driveways,
existing or proposed
operate on
water wells,
water
ways; surface
and sub surface drainage
replaced with uncompacted materials.
facilities,
lakes,
nate rock
with native materials or spoils from the excava-
tion' Level
the rock surface (+- 1o> before installing the
perforated pi�e.
ponds� and
all other facilities
requiring
separation
di w.
tances from
the pr
system.
Notify
Oener or
Engireer of
any observeJ possible
conflict.
end of tronch. Record the finish ground eleva~
tion at each
4.2 Stake
alignment of system
with
markers showing
the
protective distances
from wells and
water
bodies.
4.3 EstabliIh an elevation benchmark. This BM shall be
easily identifiable. stable and Permanent. An arEli trary
elevation of 100 can he assigned
4.4 Install the tank as shown on the drawings. Record the
inlet and outlet elevations of the tank. Tank shall be
placed on undisturbed native mil—
c:: a Vol E-- e
oil.
cavate
the absorption field. Bottom of excavation
shall be
level and scarificod ^ If sidewalls smears, they
shall also
be scarified. Record elevation of beginnin�,
middle and
end of Record elevation of each corner
and cenI-er
point of bed. Construction equipment shall not
operate on
the floor of the excavation. Any material com~
pacted by the
operation of the construction equi�ment shall
removed and
replaced with uncompacted materials.
4.6 Place
the rock to the depth specified. Do not contami�
nate rock
with native materials or spoils from the excava-
tion' Level
the rock surface (+- 1o> before installing the
perforated pi�e.
4.7 Install
the distribution pipe. Record the elevat�o: of
each joint.
For pressure system solvent weld the joints.
4.8 Cover
the distribution pipe with rock, and cover the
excavation
with geotextile before backfilling and placing
insulation,
if required.
4.9 Record
the f�nis�eJ ground elevatio: at the beginning`
middle and
end of tronch. Record the finish ground eleva~
tion at each
corner and at the midpoint of the bed.
4.10 Furnish
to copy of all survey notes to the Engineer.
5.0 INSPECTIONS
5.1 A minimum of three inspections are required. The
Specifications for septic system installation
Lot 3 JEM Subdivision
pg.3 ^
first inspection will be of t11e open excavation. At this
time the soil conditions will be observed and compared to
the or presence
of bedrock will be verified.
The second inspection will be after placement of qrav(nl,
standpipes, distribution piping; tank(s} and other compo~
nents as specified.
The third inspection will be after completion of the work.
Any deficiencies will be noted and the Ciot-rattor notified.
Such deficiencies shall be corrected within ten days'
5.2 All electrical work requiros either an MOA electrical
inspection or cerLification by an licensed electrician.
Submit proof of inspection or certification to the Engineer.
Submit catalog data of all mechanical equipment.
5.4 Notify Engineer at least 24 hours in advance of begin-
ning any work.
~
Specifications for septic system installation
Lot 3 JEM Subdivision
�j C'
"v -5-p" vv
/Vo
le rov 1-31e /W2 AE,!12
oil
fL I ------- �'
ip'A 'p,
�5 9
60'
A=r4-
T-A�
4r?
le
Iry
- r -T-
16 0-/
3
J�7
SH T. Z OF ¢
1 OG OF SOIL TEST',
DATE; Flu c. T 13t�'
13Y:�`-' vrtl,8-t i iJi s i Off!
TYPE 80RINAl-OIFIr LOCATION: �EE /�L.4-T'
U.
U. J wJ
O a.
a. SOIL DESCRIPTION
w (n `)
0 ^11 /O {^y
7-
5
4a
15
25
35
RFACE. ELEV.
- 0
-
51L
_ S,�Nay Lr e,4 vE� Glut/ /-i/r G
4a
zovvp
:.4gs}N oo ni E r�
- MAR
ATES --203 WEST 15TH AVE.--ANCH
Sh 1.cZ_Vr=_
LOG OF SOIL TESTNQ 3-7—
DATES =clv,� v z� i 9 B � .
--BY-
TYPE BORING: d H2O Plv- LOCATION:.t�
U. J W :
O a.J
� g �
SOIL DESCRIPTION
a } �¢
m
r
SURFACE: ELEV.-
/ D,2GA-NiC�
^ O.4M
5
10
r
r
RNARD-MARTH 9 ASSOCIATES --203 WEST 15TH AVE.--ANCWORAG
DATE
LOG OF SOIL TEST- %h - '
BY:. p� - _ ---�f J '= J 8171Y1S7aRl'
TYPE BORING: g� D DN Nob+�+��1L LOCATION: 4-5A--p'�-A!'
z m SOIL DESCRIPTION
w
w
a SURFACE: ELEV.
i
1-5
S/LTS� 5�4n/pS" Gizmo dEL GNI
10 '' y
f�a G'�dE.� ; 11 T -,e 7,+(3.iz-= MAY 6E LoyvEe
6w
15 ��•� ,
�D
20
-30-
35-1
D-MARTH 9 ASSOCIATES/ X2103EAST 15TH AVE. --AN
LOCATION OF WELL
BOROUGH I SUBDIVISION I I+OT BLOCK
R9644- j �M
DIRECTIONS:
(✓
MRASURING POYNT: top of casinq
ground surface rthex:_T...
BOREHOLE DATA: Depth
Materia tvr)e -;ind color Frrnr, I re,
41
I
1 elo
I RECEIVED I I
1991
Municipality
REMARK 7 -
A } nvLt -c ) iF
Av w
CONTRACTOR INFO, TION:
/-% A � 1! 1 ,, A / /
Redi(iYtered Business
Signatuxe of Authorized Reoesentative
n
Date`T
• nXPARTMEN'T Or NRTURAI, ItF 90MC99
01VISION of GEOLOGICAL AND GEOPHYSICAL SURVEYS
WATER WELL RECORD
��
' OTRS I 1.2-H S 1 3 G 6W I MERIDIAN N
WELL OWNER: A-V
/ge'o-m-e—
WELIr SEPTA:/ DATi; OF COMPLETION;
Depth uI ljuJ.e: 026 2S ft
Depth of casing:-243—ft 6 --
STATIC WATER t. Data Sn•�
METHOD OF DRILL) NG: ®ai,r, rotary
[]cable tool []other:.--_
USE OF WLLL; ffaomem i,c ❑ xii,yation 0monito5:
public supply other-................._.........
CASING: Sti.ck-up.'?•.,ft. Diam. in
WELL INTAKE: open end 17screened
(] perforated Dopen hole
Depths of openings:- to _ T ft
SCREEN TYPE: Diam: in
Slot/Mesh Sire: _. Length: ft
Set Hetween and �ft
GRAVEL PACK 'PYPE::
Volurne used:_ — Dapth to Cop:
GROUT TYPE; vo3urne:
Deptn: horn ft to
DEVELOPMENT METIOD: JYtl
Duration:,
PUMPING LEVEL AND YIELD;
C24-p—ftafter—y—hrs pumping(*—gpm
PUMP INTAKE DEPTH: ft Horsepower:_.
Date Pump Installed v_-
WAT%R CHEMISTRY SAMPLE TAKEN? U yes
WQ11, di PinfRntRri anon ommrilotinn 7 44,u'ia
PLEASE MA21, Wli= COPY OF' LOG W.M.FN 45
DAYS 7'O:
DGGS
PO 1.3OX 77-2116
EAGLI•; RTVERf AK. 99577
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel 1. D. 015 242 66
1. GENERAL INFORMATION
Complete legal description JEM LOT 3
Location (site address) 12161 GALENA
Current property owner(s) MARSHALL
Mailing address
Expiration Date: J - ) - 2 0 Z-�__
Day phone
Real estate agent Day phone
2. TYPE OF DWELLING:
0 Single Family (w/ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS:
3
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
El
Private SepticX❑
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request tor: N O N E
q Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ 5 5 O Waiver Fee $
Date of Payment a 1 a O 22 Date of Payment
Receipt Number Uq 5 b
Receipt Number
COSA # 05 C 1 1100 Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation.
Name of Firm C&M ENGINEERING Phone 8545558
Address 20182 TULWAR
Engineer's Printed Name CHARLES BALZARINI
6. DSD SIGNATURE
System #1 Approved for bedrooms
System #2 Approved for bedrooms
Disapproved
Conditional approval for
Date 3/12/22
OF Al 4
Aw
i `�49 TH
�J :�• .. . _ : ,
r r.HARLES G BALZARIKI .
����'��• CE -13854 .•'c�`v��
li`F�PROFESSIONP .�
AW
bedrooms, with the following stipulations:
a WAST'_-V`IATER o
J
�� SER\',
� f
BY (� Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
Legal Description: JEM LOT 3
If more than 1 septic system on lot: COSA Checklist # 1 of 1
A. WELL DATA
❑ Well log is filed with Onsite (or attached)
Date drilled 8/20/91
Total depth 268 ft
Cased to 33 ft
OR Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) +24 in.
Date of flow test for COSA 33/8/22
Static water level at beginning of test 33 ft.
Comments Pump Set at 240' per pump install log
B. TANK DATA
Age of tank(s) 0 years
Tank type/material septic PLASTIC
Measured operating fluid level in septic tank na
❑ Standpipes/foundation cleanout per record drawing
Date of pumping na -
D. ABSORPTION FIELD DATA Shallow Trench
Which system tested (date installed) 2014
OR ALL standpipes present per record drawing
Total measured depth from grade 7.5 ft (max)
Measured depth to pipe invert from grade ft (min)
❑ N/A — pressurized field
❑ Monitor tubes go to bottom of effective. If not, state
depth into effective
❑ Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced na gallons
Comments/Deficiencies:
COSA Checklist yellow sheet
Parcel ID: 015 242 66
Structure served by this system 1
Well production at time of test 1.1 gpm
Water storage tank volume NA gallons
Well disinfected for coliform test? ❑ Yes ❑ No
❑ Coliform bacteria is Negative
Nitrate 1.39 mg/L IF, Nitrate less than MRL (ND)
Arsenic ND ug/L ❑ Arsenic less than MRL (ND)
Collected by C.BALZARINI
Date of Sample 3/9/22
C. LIFT STATION
❑ Required maintenance completed
Age of lift station 8 years
Lift station material steel
Comments:
Adequacy test date 3/8/22
Results LDPass For 3 bedrooms
Fluid depth prior to test 15 in
Water added 450 gal
New depth 20 in
Elapsed time 1440 min
Final fluid depth 12 in
Absorption rate 450 gpd
Any rejuvenation treatment (past 12 months) na
If yes, enter date na
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
® Yes
if No
Community Sewer Manhole/Cleanout > 100'
r Yes
if No
ft
M Yes
if No ft
Neighboring Tank > 100' Yes
if No
ft
Private Sewer/Septic Line > 25' M Yes
if No ft
Absorption Field on Lot > 100' Yes
if No
ft
Holding Tank > 100' Q✓ Yes
if No ft
Neighboring Absorption Fields > 100'
Yes
if No
Animal Containment > 50' M✓ Yes
if No ft
E✓ Yes
if No
ft
if No
ft
F. ENGINEER'S COMMENTS
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' �✓ Yes
if No
ft
P1 Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10' M✓ Yes if No ft Surface Water > 100' Q✓ Yes if No ft
Property Line > 5'
® Yes
if No
ft
Wells on Adjacent Lots:
Absorption Field > 5'C]✓
Yes
if No
ft
Private Wells > 100' ❑✓ Yes if No ft
Water Main > 10' _
Yes
if No
ft
Community Wells > 200' 0 Yes if No ft
Water Service Line > 10'
Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'
Yes
if No
ft
Private Wells > 100' Yes if No
Water Service Line > 10'
0
Yes
if No
ft
Community Wells > 200' 0✓ Yes if No
Surface Water > 100'✓Q
Yes
if No
ft
F. ENGINEER'S COMMENTS
G. ENGINEER'S CERTIFICATION
l certify that / have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date. 3/24/22
COSA Checklist yellow sheet
:-%.N
49 TM '•
.. .... r�...
jj C HARLES G BALZARINI
r� Fc CE -13854 • ��
A
PROFEWCP
ft
10
Owner MARSHALL
Septic Tank:
Lift Station/Pump Vault
Street Address 12161 GALENA
Sludge level 0 inches -Pumping: required es no •Pumping completed yes no
Lift station:
-Pump basket cleaned kes no -Effluent filter cleaned es no
-Control floats cleaned yes I no -Proper float settings confirmed es no
-Operation satisfactory 5L no
Alarm System:
-Dedicated electrical alarm circuit es no -Audible and visual alarm inside dwelling e no
-Alarm system operation atisfactor not satisfactory
Manhole Riser
-Ground water intrusion at riser to tank connection es no
d
-Grounwater intrusion around pipe penetrations es no
es
-Manhole lid: Functional no Insulated es n
Other
-Weep hole functional es no
Properly Secured es no
-All manufacturer required inspections and maintenance completed
Comments:
Qualified Maintenance Provider:
Technician C.BALZARINI
Company
C&M ENGINEERING
Signature
es no
Date of maint,-nanr-a 3/8/22
Date 3/28/22
,E P
D �
• Municipality of Anchorage
On -Site Water and Wastewater Program
(907)343-7904
Certificate of On -Site Systems Approval
Parcel 1, D. 015-242-66 Expiration Date: 3 ' L
1. GENERAL INFORMATION
Complete legal description JEM, Lot 3
Location (site address) 12161 Galena Circle Anchorage, AK 99507
Current Property owner(s) Michael & Cynthia Bradley Day phone
Mailing address 12161 Galena Circle Anchorage, AK 99507
Real Estate Agent Day phone
2. TYPE OF DWELLING:
❑ Single Family (w/wo ADU) �� 9All
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex) MAY 14 2014
3. NUMBER OF BEDROOMS: Three
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well 0 Individual IID
Individual Water Storage ❑ Holding Tank ❑
Community Class Well ❑ Community ❑
W.fAr F-1 Public Sewer ❑
WaiverNariance request for:
r
Received by: ° _ �' ' ti_ 4 Date. t
COSA to be released.6 the.engineer, unless otherwise requested by the engineer.
COSA Fee $2-Gt ��
Date of Payment Sf 1!!5Ll
Receipt Number OCA g2=4
COSA# 0-,>Clq IIV?
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Anderson Engineering
Phone 522-7773
Address P.O. B:Dx 240773 Anchorage, AK 99524
Engineer's Printed Name Michael E. Anderson, P.E.
Date 5/14/2014
6 i Iz
6. DSD SIGNATURE
r
'"�`�
System #1 Approved for bedrooms
System #2 Approved for bedrooms
Disapproved
PCFFgS10�U=
e
Conditional approval for bedrooms, with
the following stipu action
V: Original Certificate Date: "� 3' 7
Th nicip ity,' Anorage Development Services Division (DSD) issues Certifcates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet ! - . c
If more than 1 septic system is on the lot:
COSA Checklist # of _
Structure served by this system
Certificate of On -Site Systems Approval Checklist
Legal Description: JEM, Lot 3
A. WELL DATA
Well type Private
Date completed 8/20/91
Total depth 268 ft.
If A. B, or C provide PWSID #
Sanitary seal (Y/N) Y
Cased to 33 ft.
FROM WELL LOG
Date of test 8/20/91
Static water level 19
Well production
'n
ft.
Parcel ID: 015-242-66
Well Log (YIN) Y
Wires properly protected (Y/N) Y
Casing height (above ground) >12 in.
AT INSPECTION
11/21/13
22.5 ft.
g.p.m. 1.2
g.p.m.
WATER SAMPLE RESULTS:��
Coliform 0 colonies/100 mL Nitrate mg/L ^ ?
N/D 1 +',-
Arsenic ug/L Date of sample: Collected by: Anderson Eng.
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/Steel Date installed 8/31/91
Tank size 1,000 gal. Number of Compartments 2 Cleanouts (Y/N) Y
Foundation cleanout (Y/N) Y Depression over tank (Y/N) N {{ High
/water
ralarm (Y/N) N
Date of pumping 1 °� ,� ��� Pumper.
C. ABSORPTION FIELD DATA
Date installed 11/21/13 Soil rating (g.p.d./ftz or ftz/bdrm) 1.2 GPD/SF System type 5' Wide Trench
Length 40 ft. Width 5 ft. Gravel below pipe 4 ft.
Total depth 8 ft. Eff. absorption area 400 ftz Monitoring tube Y Depression over field N
Date of adequacy test New Const. ResultsPass/Fail
( ) For _bedrooms
Fluid depth in absorption field before test in. Water added gal. New depth in.
Elapsed Time: min. Final fluid depth
in. Absorption rate >= g,p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date
D. LIFT STATION
Date installed 11121/13 Size in gallons 500 Manhole/Access (Y/N) Y
"Pump on" level at 40 in. "Pump off- level at 40 in. High water alarm level at 45
Datum Bottom of Tank Cycles tested New Const. Meets alarm & circuit requirements? Y
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on tot > 100'
On adjacent lots > 100'
Absorption field on lot > 100'
On adjacent lots > 100'
Public sewer main N/A
Public sewer manhole/cleanout N/A
Sewer /septic service line >25'
Holding tank N/A
Animal containment areas
Manure./animal excrete storage areas >100'
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >5r Property line >5r Absorption field >5
Water main N/A Water service line
> 10' Surface water > 100'
Wells on adjacent lots> — �l
C�
ABSORPTION FIELD ON LOT TO:
Property line 0 Building foundation
> 10 Water main N/A
Water Service line >10, Surface water > 100' Driveway, parking/vehicle storage >10,
Curtain drain None Noted Wells on adjacent lots
>100'
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that t have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Michael E. Anderson, P.E.
Date 5/14/2014
COSA brown sheet 10-10-12.doc
OF A4 P4
< .i
-..x ...............ao...,
=MICHAB_ E. P-7—KON
CE - 43331
Vi ES90
G\qG
G
00
yo•
?1
L-104.72•,
I N
I
I
2
I
� � 1
o E I
�d I
NI
180.00'
m
S83° 00' 00"E
(
LUI
F-
ff
CAR I
':.': GA7.• 6 ::.
I
PORT I W
Z
I J O
29.0' SHED F, n.
.......
I � O
...',','
4 EXISTING'
I -. .. ...
HOUSE WELL
W
'
' 20.0' ° 0:
i a
o I W
CD
UJ
SANS
0
Z o
10' UTIL ESMT
,— __ N
N89° 39' saw
329.16`
UNDER NO CIRCUMSTANCES SHOULD AN AS-BUILT BE USED FOR CONSTRUCTION OR FOR ESTABUSHING BOUNDARY OR FENCE LINES.
THE SURVEYOR TAKES RESPONSIBILITY FOR THE INITIAL TRANSACTION ONLY AND ASSUMES FINANCIAL LIABILITY ONLY FOR THE COST OF THE SURVEY.
LISTED DISTANCES PREVAIL OVER SCALING. REPRODUCTION MAY CAUSE ERRORS IN SCALE.
LOT=SURVEY TYPE
SYMBOLS
FOUNOAndi AS-BUILT
❑ FINAL slRucnRE A5-ButtT
mp••
SET REBAR
� � DRNkAGE �"�`�'��' ASPHALT
❑ PLOT PLAN ... TOPOGRAPHY
LOT SSEczR
O FOUND REBAR g_g_g WOOD FENCE'`°'`"' CONCRETE
OOp ASSUMED ELEV.
�
O CORNER...
5-BUI 7 ... NO CORNERS T (fECERnFlGAn $-BUttT ... NO CCtiNBiS SET
rTc
'>f-X—)EMETAL FENCE ® WOOD DECK
PLOT PLANS & LOT SURVEYS
NOTE:
IT IS THE RESPONSIBILITY OF THE BUILDER OR OWNER, PRIOR TO
ONLY THOSE IMPROVEMENTS ABOVE GROUND AND VISIBLE WILL BE
CONSTRUCTION, TO VERIFY PROPOSED BUILDING GRADE RELATIVE
SHOWN. FENCES, WELLS, SEPTIC CLEANOUTS, SIDEWALKS, DRIVEWAYS,
TO FINISHED GRADE AND UTILITY CONNECTIONS AND TO DETERMINE
ETC., ARE SHOWN IN THEIR APPROXIMATE LOCATION, ONLY. SNOW
THE EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS
MAY PREVENT SOME IMPROVEMENTS FROM BEING SEEN AND LOCATED,
WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT.
ALL DISTANCES ARE RECORD UNLESS OTHERWISE NOTED.
SURVEY CERTIFICATION
��rartq�
OF„•
Prepared by
Robert E. Johns, Jr, & Assoc.
PLOT PLAN
"'Dyor "°l'"°w °'y•
1 4 tra.n mG t I E nr” eN A I
♦♦.•.�E
��
Professional Land Surveyors
nvn Iwnd « alaR,nM a a 9. let .
•p
4D
1 •1'
1700 Brink Onus.
1700
m a,. °tm as t° lnr nut 0 mY
F1wM.da. and aea.A a emntlern nm. Ma
♦ �• ,
H
ANCHORAGE, ALASKA 99504
Scale: n ,
1 = 50
Rec. lot S.F.
Rec. Plot File Na
f th :, /
�^
FOUNDATION AS-BUILT
I, R°nrl E blm4 °'. Iwtly aNy q°I I
na.. AtM14..a aa.
bl aM tlal a'B»
�•^• •.
/ /
/.. , , „w
•
Dote Surve d
Ye'
12/12/13
Drown b REJ
}�
Chocked bJMK
annYa. °,a nrrm°aa a Imm�
Am�„.tel wa.
«ln;•n ;,�:
ROSERT E. NS, J :
9
Date Drawn:
Grid:
b;.>a
;` ;
��0 4121—S
12/13/13
2740
w.o. 13-638
FINAL STRUCTURE AS-BUILT
•. ,eS:
Legal DesaEPtfon:
Lot 3
L Robed c .ynnt r., n«ar arey 9°l 1
alrvshr. m 9h bl ad Uwl a .
�♦ 1e^•••.,• ••••,.•••yam:♦1
���
��,� �0t1R0wM�mht.�itl°«.^1 �^
p�oTe9elanal �a°�♦•
r ,
y
Municipality of Anchorage
. *AE
Development Services Department Building Safety Division
On -Site Water and Wastewater Program
4700 Elmore Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D... O15- 247-- (*�p COSA # c4) Cr 0' O
Expiration Date:
1. GENERAL INFORMATION
Complete legal description Tern LJ 3
Location (site address) 12.%61 GG41r ,g Cir. , Av%Aoraae AK 9951(0
Current Property owner(t) Margref M44n MAV) Day phone 3V5- ZO2 -2.
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing Address
Day phone
y SkeY15 Day phone 273- '}7-o(.
Unless otherwise requested;. COSA will be held by DSD for pickup. o f< 5;,r uhf Pv
2. NUMBER OF BEDROOMS: 3
3. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
®
Individual On-site
(�C]
Individual Water Storage
❑
Individual Holding Tank
❑
Community Class Well
❑
Community On-site
❑
Public Water System
❑
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by.an independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in theprofessional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my. investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Fn4,n ,ri„4 1
Address 203 W 1541% Av@ Sfc 202 �1�GhOra42 A K 71501
Engineer's Printed Name Laps Sp a k1 ♦,_,A
5. DSD SIGNATURE
...�'`� Approved for bedrooms.
Disapproved.
Phone 2 7f -_Wy
Date Vzs% zo I /
Conditional approval for bedrooms, with the following stipulations:
Attachments:
COSA Checklist X
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
WASTE NAIER
PROGRAM
^• �.�
I
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
--�AtOOriginal�_
BY: -' Certificate Date.
(Rev. 11/05)
Municipality of Anchorage
• ''� Development Services Department
u �
z
Building Safety Division `
On -Site Water & Wastewater Program r-11
4700 Elmore Road
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: Tem Lof 3 Parcel ID: 015- ZVZ- (o(o
A. WELL DATA
Well type Friyw}e If A, B, or C provide PWSID #
Date completed $ ZO 1991 Sanitary seal (Y/N)�
Total depth 269 ft. Cased to -33—ft.
FROM WELL LOG
Date of test 61201 In
Static water level 1i ft.
Well production y g.p.m.
WATER SAMPLE RESULTS:
Coliformcolonies/100 mLNitrate 1.0 mg/L
Arsenic: ND ug/L date of sample: Jl2011
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Greer Sf eat
Tank size l 000 gal. Number of Compartments 2 -
Well Log (Y/N) 'Y
Wires properly protected (Y/N) Y
Casing height (above ground) Zy in.
AT INSPECTION
1 9—
p.m-
Collected by: La•!s SAy,2lZ.�ahc1
Date installed 91311 wo l94 !
Cleanouts (Y/N) Y
Foundation cleanout (Y/N) Y Depression over tank (Y/N) _ V High water alarm (Y/N) /t/
Date of pumping '31,11Z011 Pumper At Norge Servs Leo
C. ABSORPTION FIELD DATA
Date installed $ 3/ Z°ll Soil rating qaia6or ftp/bdrm) 0.9 System type S; OW IrMCk
Length 90 ft. Width .5 ft. Gravel below pipe �o _ ft.
Total depth W+ ft. Eff. absorption area 5Jft2 Monitoring tube Depression over field
Date of adequacy test _11211 2011 _ Results (Pass/Fail) P465 For -3 bedrooms
Fluid depth in absorption field before test 10 in. Water added 00 gal. New depth F� in.
Elapsed Time: Y O min. Final fluid depth 10 in. Absorption rate >= qSO 9-p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) Vogt kNown If yes, give date
D. LIFT STATION
Date installed Size in gallons Manhole/Access (Y/N)
"Pump on" level atin. "Pump off" level at in. High water alarm. level at in.
Datum Cycles tested Meets &circuit uirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot 100'4-
Absorption
00'+
Absorption field on lot
..
Public sewer main
Sewer /septic service line 25 1+
Animal containment areas 5D I+
On adjacent lots too'+
On adjacent lots 100,+
Public sewer manhole/cleanout N
Holding tank __ /✓�/{
Manure/animal excrete storage areas
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5�+ Property line 51+ Absorption field 5 +
Water main IVIA Water service line 1014- Surface water too I+ Al 0.
Wells on adjacent lots 100
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 101+ Building foundation A 0 4- Water main /y
Water Service line 10 Surface water 100+ (N-0.) Driveway, parking/vehicle storage S1
r
Curtain drain 50 + N.O. Wells on adjacent lots /00 � t
F. COMMENTS
G.
ENGINEER'S CERTIFICATION — .�F..0 F `A�'9
I certify that I have determined through field inspections and % �`
review of Municipal records that the above systems are in ,, . , ; ...9
conformance with MOA COSA guidelines in effect on this date. �. J'
Engineer's Printed Name Lars
115 Q .SF
Date 4281lot1 �FO Zoll
. , N�-�"
11�PF� FE_ S1G.,..
COSA Fee $_ O �" 1
Date of Payment
Receipt Number lJv� `l 53
(Rev. 4/10)
Waiver Fee $
Date of Payment
Receipt Number
I
MUNICIPALITY OF ANCHORAGE
® DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services F$'
On -Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
Parcel I.D. # D )S ' 2YZ — 6C HAA #
1. GENERAL INFORMATION
Complete legal description Tem S'l/)
Location (site address or directions) 2161 Galena C1�c <<
Property owner Pne1";r't 1-C'4¢ar, Day phone 2S7 -Y21 2
Mailing address P.O. 13oxyt31 6/ Anchorc3Qp
Lending agency Pa c1A'c 1`tor f qca�� Day phone
Mailing address
Agent 1\164 e- - Fa- S�1e 64 Day phone
Address
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS: 3
3. TYPE OF WATER SUPPLY:
Individual well Is
Community well
Public water
NOTE: if community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
4. TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding tank
Community on-site
Public sewer
NOTE: if community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 (Rev. l/91) Front MOA P21
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I furtherverify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
6. ®HWS SIGNATURE
i/ Approved for
Disapproved.
M )E bedrooms.
Conditional approval for
Additional Comments
in
Pe
bedrooms, with the following stipulations:
Date !2r— %_-�_�
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
,72-025 (Rev, 1/91) Back MOA #21
Municipality of Anchorage /
DEPARTMENT OF HEALTH & HUMAN SERVICES AUG
Environmental Services Division MUNICIPALITY OF AN
825 L Street, Room 502 • Anchorage, Alaska 99501 • (907) 343�4714 AL SERVICES DIVISION'
Health Authority Approval Checklist
Legal Description: L v h 3 Tem S16 Parcel I. D.: 6 rs - 2 `/ Z - 6'C
J
A. WELL DATA
Well type /'v If A, B, or C, attach ADEC letter. ADEC water system number
Log present (Y/N) Y e -r Date completed v9/ ZU / 9 "
Total depth 2G B ` Cased to 13eG vck-.3j ' Casing height (above ground) 1'5
Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y
FROM WELL LOG AT INSPECTION
Date of test &f 20 /Y /
Static water level /91
Well production
WATER SAMPLE RESULTS:
MW
Coliform Dcoloniu Ito0m4' Nitrate H•7/ Otherbacteria 1)o4e Ce�o�f��
Date of sample: 8/.31319 Collected by: 7'• F. Maa s
B. SEPTIC/HOLDING TANK DATA
Date installed &/3J /9/ Tank size/ Number of Compartments -a Cleanouts (Y/N) t
Foundation cleanout (Y/N) Y Depression (Y/N) A/ High water alarm (Y/N) Al.4
Date of Pumping &I'S- /Y7 Pumper A*
C. ABSORPTION FIELD DATA
Date installed 81311911 Soil rating (g.p.d./W or ft2/bdrm)0. 9 %4d System type
Length U00 ` Width S Gravel thickness below pipe 2 ' Total depth 3 - ( `
Effective absorption area S -7/ 0` Monitoring Tube present (Y/N) Y Depression over field (Y/N) N
Date of adequacy test 8/3120 Results (Pass/Fail) For 3 bedrooms
Fluid depth in absorption field before test (in.); Immediately after-6gal. water added (in.): I I S/8
Fluid depth 10 f16 (ins) Minutes later: 129 Absorption rate = > Y.SG g.p.d.
Peroxide treatment (past 12 months) (Y/N) /Vane known If yes, give date Al -14
72-026 (Rev. 3/96)`
D. LIFT STATION V A
Date installed
Manhole/Access (Y/N)
High water alarm level at*
Cycles tested
E. SEPARATION DISTANCES
Size in gallons
"Pump on" level at*
*Datum
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic/holding tank on lot /'/d'
Absorption field on lot z 16o'
Public sewer main A/.
On adjacent lots
On adjacent lots
"Pump off" level at*
n'
Z.5
I Is -
Public sewer manhole/cleanout N.
Sewer /septic service line -> '2 r' Lift station Al. A•
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO:
Foundation Ts Property line 3S" Absorption field "Id
Water main/service line > t o' Surface water/drainage > too, Wells on adjacent lots > too '
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10 Building foundation 7S' Water main/service line > 10'
Surface water > 100' Driveway, parking/vehicle storage area S
Curtain drain None seen Wells on adjacent lots tUU
F. ENGINEER'S CERTIFICATION
I certify that l have determined thru field inspections and review of Municipal records that, the above systems are
in conformance with MOA HAA guidelines in effect on this date.
Signature
f 9«iTGs.s4vf Wtlka i+RNj4
Engineer's Name %heV45&re-
Date
Y;.
HAA Fee $ Waiver Fee $
Date of Payment /� Date of Payment
Receipt Number Ci 1 �/ Receipt Number
72-026 (Rev. 3/96)*
MUNICIPALITY OF ANCHORAGE L�
• '� DEPARTMENT OF HEALTH & HUMAN SERVICES M},�
Division of Environmental Services —
On -Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
Parcel I.D. # Q I — aV2 —1'a 6
HAA#
1. GENERAL INFORMATION
Complete legal description -cry( 3 �`'� S Ill
Location (site address or directions)
Property owner 6104 e_,L'0�9 670,WS4"a4v" Day phone 3` q— Yf A0
Mailing address P jooX A &,
Lending agency
Mailing address.
Agent
Address
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
Individual well
Community well
Public water
Day phone
Day phone
NOTE: If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
4. TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding tank
Community on-site
Public sewer
NOTE: If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025(Rev.1/91) Front MOA#21
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I furtherverify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm ���>�' �j r A i r [,C_ (,k � I V Phone. X27 g` 3 i 6 6
Address
Engineer's signature
6. DHHS SIGNATURE
o2L� ..�/ IT
Approved for bedrooms.
Disapproved.
Conditional approval for
Additional Comments
Date )2110/`1
bedrooms, with the following stipulations:
Date/2"2C%- /1
CAUTION
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in orderto satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
72-025 (Rev. 1/91) Back MOA 421
,fr
-Ks I -
Municipality of Anchorage
Department of Health & Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: It 69' f't Parcel I.D. 0
A. WELL DATA
Well type R_ If A, B, or C, attach ADEC letter. ADECwater system number NIA
Log present (Y/N) �Z %
Date completed 9/6 ` q( Driller Al pi ty
Total depth Cased to
- Casing height ; �
Sanitary seal (Y/N) Wires properly protected (Y/N)
Date of test
Static water level
Well flow
FROM WELL LOG
a�gl
AT INSPECTION
WATER SAMPLE RESULTS:
Coliform to Nitrate oga �2 Other bacteria
Date of sample: �c 1 q `Z ( Collected by:
M
Z
a ``0
w O
PLIMP
level
O �
SEPARATION
DISTANCES FROM WELL TO:
Septic/holding
tank on lot
; On adjacent lots —
a �
Absorption
field on lot
g.
On adjacent lots
Llnl1
PLiblic
sewer main
I�1A
Public sewer manhole/cleanout _
Sewer service line
U
Petroleum tank N
WATER SAMPLE RESULTS:
Coliform to Nitrate oga �2 Other bacteria
Date of sample: �c 1 q `Z ( Collected by:
M
Z
w O
O �
a
z u
LLI
a �
g.
~
Llnl1
P -
1
C]
d
W
Z
L<?
B. SEPTIC/HOLDING TANK DATA
Date installed -Tank size Compartments
Cleanouts (Y/N) rtenn—Foundation cleanout (Y/N) Depression (Y/N)
High water alarm (Y/N) �� Alarm tested (Y/N) N
Date of pumping k
Pumper
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO:
1Z
KI
Well(s) on lot /37 On adjacent lots % Imo' Foundation &, l
To property line ® I Absorption field 14Z Water main/service line i -5 0
Surface water/drainage N//-\
72-026 (Rev. 7/91) Front CONTINUED ON BACK PAGE
C. LIFT STATION I`/A
Date installed
Size in gallons
Vent(Y/N)
High water alarm level —
"Pump on" level at
Meets MOA electrical codes (Y/N)
Manufacturer
Manhole/Access (Y/N)
SEPARATION DISTANCE FROM LIFT STATION TO:
Well on lot
D. ABSORPTION FIELD DATA
Date installed
1
Length g"y Width
Total absorption area
Depression over field (Y/N)
Results (pass/fail)
On adjacent lots
25 1
57
Peroxide treatment (past 12 months) (Y/N)
"Pump off" level at
Cycles tested
Surface water _
Soil rating - System type
1
—Gravel thickness C2 Total depth
Cleanouts present(Y/N) a
_ Date of adequacy test N _4
for i3Gt_4_c>e' iLr,S bedrooms
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
If yes, give date
Well on lot On adjacent lots > /rte Property line
To building foundationf 7 �5 1 To existing or abandoned system on lot
On adjacent lots i % Cutbank i`///% Water main/service line i s U
Surface water Driveway, parking/vehicle storage area 15
Curtain drain YZLA
E. ENGINEER'S CERTIFICATION
1 certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect,on the,date of this inspection.
Signature
Engineer's Name I � �+ Pu'r(detcup j>
Date ` `0 1 Cl V ✓' r
)
HAA Fee $
Date of Payment % L-- —V
Receipt Number 8 3 ;;� `Y7 LAI -7.5
72-026 (Rev. 3/91) Back MOA 21
Waiver Fee: $
Date of Payment
Receipt Number
GALENA
CIR.. �a
V
JC74 SUBDIVISION
LOT 3
w
�N
LOT 3
-5sPrc
FIEta
.-- PX(sTJNC, GRAVEL
Dptve
5-0
s 83' ao t6n ••
11�. 184. qd
Plbpl sri4�
DRIVEWAY
UNDEI�GROUNO �rlQ
oW;a—rvt fol UTIL. rw$MT-
N 8qv �a9'So" �►!
a
EXISTJ NC,
BUIL.GING
F.P. CANT•
Tqa
I hereby certify that I have surveyed
AS BUILT
the property depicted above and that
GASTALDI ASURVEYING no enc
LNA roactunents exist except as indi--
Jeff; A. Gastaldi,R.L.S. Cated.. It is the responsibility of the
3034 (settles Bay Loop owner to determine the existence of an
Anchorage, Alaska 59515 -ease[nents,covenants or restrictions
Tel. 907-344-4272 which do.not appear on the recorded
suLxlivision plat. Under no circumstan-
ces should any data hereon be used for
GRID DATL construction or for establishing boun-
dary or fence .lines.
�. JOB 1,K). AN010RAGE REOORDING DIS'TRIC r, ALASKA
0 W ear_
Oggo, U.W.caur-