ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: 0SPl11321 PID Number: 051-141-02
Name:
Charles F. Stiehr Wastewater System: [] New [] Upgrade
Address:
P.O. BOX 671108 Chugiak, AK 99567 ABSORPTION FIELD
Phone: Number of Bedrooms:
3 [] Deep Trench J~ Shallow Trench [] Bed [] Mound [] Other:
Soil Rating: Total Depth from odginal grade:
LEGAL DESCRIPTION 1.2 CpD/Pt2 8.5-9.3 Ft.
Block: Lot: 47 Subdivision: Depth to pipe bottom from odginal grade: Gravel depth beneath pipe:
Delucia 4.5-6.0 Ft. 3-4 Ft.
Township: Range: Section: Fill added above odginal grade: Gravel Length:
0 Ft. 44 Ft.
Well: [] New [] Upgrade Gr~ve, w~dth: Uumberoflines: Distance between lines:
5 Ft. 1 Ft.
Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material:
Existing Ft. Ft. 455 Ft2 ASTM D3034 PVC
Driller: Date Ddlled: Static Water Level: Installer: Date Installed:
Ft. Scott's Services 11/21-22/2011
Yield: GPM Pump Set at: Ft. Casing Height Above Ground:Ft' TAN K
SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other:
T~ To Septic Absorption Lift Holding ~ublic/Private Manufacturer: Capacity:
From~
Tank Field Station Tank Sewer Line Existing Gal.
Material: Number of Compar[ments;
We, 86' >100' N/A N/A >25'
sur~acewater >100' >100' N/A N/A ~ / LIFT STATION
Size: Manufacturer:
Lot Line >5' > 10' N/A N/A Gal.
"Pump on" level at: "Pump off" level at: in. High water alarm at:
Foundation >5' >10' N/A N/A in. in.
Pump Make & Model Electrical Inspections performed by:
Curtain Drain None Noted
Remarks:
Existing Septic Tank Verified Sound for Continued Use. BENCH MARK
Location and Description:
Northwest 16' of Absorption Trench is 4' Effective Depth. Garage Slab.
Assumed Elevation:
8" Insulation Over Distribution Line Under Driveway. 100.0 Ft.
Inspections performed by: A. Harala Dates: 1st 8/28/2007
Development
Services
Department
Approval
Conditional Approval Date:
Reviewed and approved b /1~.,"~. Date: /,:~ I /
,./
O.C.
7
I
N
I,I
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number: OSP111321
Page 3 of 3
PID NO.: 051-141-02
/¢/'~==~ Existing
/ / 11,ooo Ga,on
// ' SepticTank I
EXISTING SEPTIC TANK
Tank Verified Suitable for Continued Use.
99.4
Finished Grade
Existing Grade
~90.1
81.6
No Groundwater
98.6
Geotextile Fabric
Finished Grade
Existing Grade
97.9
Drainfield Rock 93.4
44' (Trench Length)
NOTE:
Northwest 16' of Trench Has 4' Effective Depth.
Remainder of Trench Nominal 3' Effective Depth.
PROFILE AS-BUILT
On-Site Wastewater Disposal System Permit
OSPl11321
05114102000
Septic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number:
Tax Code Number:
Work Type: Upgrade
Permit Effective Dates: November 04, 2011 to
Design Engineer: ANDERSON ENGINEERING
Subdivision: DELUCIA
November 03, 2012
Site LegalAddress: DELUCIA LT 47 G:1259
Owner/Address: STIEHR CHARLES F
AKA STIEHR CHUCK PO BOX 671108 CHUGIAK AK 995671108
Site Mailing Address: 22792 NEEDELS LOOP, Chugiak
Lot Size in Sq Ft: 53579
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field N SepticTank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Special Provisions: Verify and document that the existing drainfield is constructed in accordance
with the current version of the wastewater code. Submit results with the final inspection report.
Date:
Date:
MUN
ICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
Mayor Dan Sullivan
ON-SITE SEWERNVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 051-141-02
Property owner(s): Charles F. Stiehr Day phone: 301-6243
Mailing address: P.O. Box 671108 Chugiak, AK 99567
Site address: 22792 Needels Loop Chugiak, AK 99567
Legal description (Sub'd., Block & Lot): Delucia Subdivision, Lot 47
Legal description (Township, Range & Section):
Lot Size: 53,579 Sq. Ft. Number of Bedrooms: Three
Phone: 90%343-7904
Fax: 907-343-7997
THIS APPLICATION IS FOR:
([~ all that apply)
Absorption Field X
Septic Tank []
Holding Tank []
Privy []
Private Well []
Water Storage []
THIS APPLICATION IS AN:
Initial []
Upgrade X
Renewal []
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: .'~ '2~O "'-
Date of Payment: ~ I '- t - ~
Receipt Number: ~-,~2j\ ~
Permit No. C~.~'¢ \/\ ~'~ /
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
C:\Users~AndEng\Desktop\Mike\T15N Lindberg\Permit Application.docC:\Users~AndEng\Desktop\Mike\T15N Lindberg\Permit
Application.doc
AN D ERS ON ENGI N EERI N G
P.O. BOX 240773
· ANCHO~GE, AK 99524
522-7773 677-7766 (FAX)
November 1,2011
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 Elmore Road
Anchorage, AK 99519-6650
Subject:
Lot 47, Delucia Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The existing septic system on the subject lot has failed and was recently upgraded
without a permit. The trench does not meet the minimum requirements for a three-
bedroom home and has been redesigned to meet Municipal Code as shown on the
attached Site Plan. We are therefore requesting a permit be issued for the upgrade of
the septic system to accommodate the three-bedroom home on the lot. The attached
Site Plan and backup documentation identify the location and configuration of the
existing and proposed septic system. The existing Septic Tank was recently verified
sound for continued use. A statement to that effect will be provided with the inspection
report for the new system. The existing absorption pit was completely abandoned in
accordance with Municipal Code. Also identified on the plans are the locations of the
existing well on this and adjacent lots and adjacent septic systems. No conflicts exist
between the proposed septic system and the wells on this or adjacent lots. Protective
radii are shown to the adjacent wells. Drainage arrows are shown indicating the
current drainage patterns. The drainage patterns will be maintained after construction.
The test hole placed on the lot indicated Well Graded Gravel with sand (GW/GM) the
entire depth. The percolation rate was determined to be less than 5 minutes per inch.
We have designed the new trench with an application rate of 1.2 gallons per date per
square foot. We are proposing to place an 11' extension on the existing 33' long trench
by 5' wide with a 3' effective depth. The actual dimensions of the existing trench will be
verified at the time of construction. The total depth of the system will be 8' with the
distribution line at 5' below the existing surface.
The ground surface on the lot slopes slightly to the east in the area of the absorption
Lot 47, Delucia Subdivision
November 1, 2011
Page Two
trench. The trench will be placed parallel to the contours of the ground as much as
possible and in conformance with design criteria. A minimum of 100' will be maintained
between all components of the septic system and the proposed well and from any
surface water in the area.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
Z
Z
7
~007
LOT47, DELUCIA SUBDIVISION
DESIGN FACTORS:
Three Bedroom Home
Perc. Rate: 1-5 Min./Inch
Application Rate: 1.2 GPD/SF
3 Bedrooms * 150 GPD/Bedroom = 450 GPD
SYSTEM REQUIREMENTS:
5' Wide Trench System
Existing 1,000 Gallon Septic Tank
3' Drainfield Rock
450 GPD/1.2 GPD/SF/5 SF (Width) *.58 (Red. Factor)= 43.5 LF Trench Length
THEREFORE: Construct a 44' Long x 5' Wide x 3' Effective Depth Absorption Trench.
Flow Line Elevation in Trench to be 5' Below Original Ground Surface. Total Depth to be
8' Below Existing Ground. Provide 3' CoVer Over Absorption Trench and 4' Cover Over
Septic Tank.
~Geotextile Fabric
~ 4" Perforated
PVC (Holes Down)
~ Drainfield Rock
Coarse Sand (See Specification)
TYPICAL 5' WIDE TRENCH SECTION
(NO SCALE)
NOTE: Grade Area Over Trench to Drain Away g~
Minimum 6~ Separation From Bedrock. ' ~....~....~.~.. ~..~ ....
Minimum 4 Separation From Groundwater. ~ ~..~,-~-~;~,..~
M' ' ' ' · ""'~"~'["~'~ .............
,ri,mum 100 Separat,on From Pr,vate Wells ,n the Area. ~ "'C~A~.A.D~S~~
Mimmum 100 Separation From Su~ace Water or Streams. ~.~% No. cs-~3~
A700
DEPTH
1
2
3
4
5
6
7
8
9
11
20
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
BRAGAW STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: LOT /-.7, DELUCIA SUBDIVISION
PERFORMED FOR: CHUCK STI~HR
DATE: 10/2&/2011 PROJECT No.:
PARCEL ID#: TECHNICIAN:
TEST HOLE A I
0B/0G
WELL GRADED GRAVEL
WITH SAND
GW/Gld
WAS GROUND WATER ENCOUNTERED? __
IF YES ~ WHAT DEPTH?
DEPTH OF WATER AFTER MONITORING:
DATE OF MONITORING:
B0H @ 17'
M. ANDERSON
OF ,4/;'.%
~;~ V~. ................ ~
~ 49~b ~ ~ ~
Professional Engineen S~mp:
SLOPE
NO
11/5/2011 ~
E
SITE PLAN
SEE SITE PLAN
DEPTH TO
DATE READING GROSS Tilde NET TildE WATER NET DROP
(MINUTES) (MINUTES) (INCHES) (INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
10/24 1 2:08/2:18 10 1.25"/3.50" 2.25"
2 2:19/2:29 10 1.38"/3.50" 2.12"
3 2:30/2:40 10 1.25"/3.38" 2.13"
4 2:41/2:51 10 1.25"/3.38" 2.13"
5 2:52/3:02 10 1.13"/3.25" 2.12"
6 3:03/3:13 10 1.25"/3.38" 2.13"
PERCOLATION RATE: 4.7 (MIN/INCH) PERC. HOLE DIA. 6" .(INCHES)
TEST RUN BETWEEN: 5.5 FT. and 6.5 .FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: II/1/2011
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: T15N, R1W, SECTION 18, LOT 190B
GENERAL:
The scope of this project includes the construction of a new absorption
trench 44' long by 5' wide by 3' effective depth at the location shown
on the Site Plan. The total depth of the trench will be 8' below existing
ground and the distribution pipe will be placed at 5.0' below the
surface. Approximately 33' of the absorption trench is already in place
and must be verified to be to the dimensions described above. The
absorption trench must be constructed a minimum of 100' from any
wells in the area and 100' from any surface water on this or adjacent
lots. A minimum of 3' of cover is required over the absorption trench.
In lieu of cover 2" of direct bury insulation and 2' of cover may be
placed. The delivery line from the existing septic tank must be verified
to have at least 4" of insulation.
The existing septic tank has been verified suitable for continued use.
A statement from the contractor to this effect is required.
Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines. The Contractor is also responsible to assure
the separation distance from wells and surface water in the area is
maintained. The engineer will accept no responsibility for Contractor
errors.
Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
Contractors installing wastewater disposal Systems must be certified by
the Municipal Development Services Department Building Safety
Division On Site Water and Wastewater Program for system
installations. Owners installing their own systems must receive prior
approval from the On Site Water and Wastewater Program before
beginning system installation.
Lot 47, Delucia Subdivision
November 1, 2011
Page 2 of 4
SEPTIC TANK INSTALLATION - EXISTING
1. A new l i'000-gallon septic tank must be procured from a certified
manufacturer if the tank found on site is not acceptable for continued
use.
2. A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
3. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct -burial insulation.
6. A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drainfield.
7. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the
design. The bottom of the trench shall be within 2" of level.
2. Distribution piping must be placed level with perforations down atop a
level bed of drainfield rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield
rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below the distribution pipe must be
perforated.
5. Contractor shall verify the septic tank and drainfield are a minimum
100' away from any private water wells in the area, 150' from a Class
Lot 47, Delucia Subdivision
November 1, 2011
Page 3 of 4
"C" Well or 200' from any community well. The Contractor is solely
responsible to assure these separation distances are met.
Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
A minimum 2' of accepting soil is required below the drainfield rock for
a 5' wide' trench. Contractor shall verify this condition prior to
placement of the rock. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic
tank manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections must be
completed during the construction of the septic system. These.
inspections must be conducted under the supervision of a professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
Lot 47, Delucia Subdivision
November 1,2011
Page 4 of 4
be backfilled. The Contractor must notify the engineer 4 hours prior to the
inspection to prevent delays.
The second inspection must be conducted after the placement of the
geotextile fabric, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as-built of the completed system.
His measurements must include verification that the proper separation
distances have been met. A certified surveyed as-built may also be
required to assure the proper separation distances are met from wells in
the area. The as-built will also include separation distances from streams
or surface water in the area.
GRE,..ER ANCHORAGE AREA BOR JGH
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL. SYSTEM .
/ ..... MAILING ADDRESS ~)' '(" ' '~:~'' ~ ~'':' / ';~' ,7'~ ' PHONE ~'C~"
LOCATION ' .,~ '~ - LEGAL DESCRIPTION ~ ~'.-~ W./ ~L~-~t,.~
SEPTIC TANK:
/ NUMBER OF
DISTANCE
FROM WELL ~ ~' MANUFACTu R E R ¥''/~'~ f'~ MATERIAL COMPARTMENTS
CAPACITY/~d-~
INSIDE LENGTH ~ INSIDE WIDTH LIQUID DEPTH LIQUID
GALLON~.
~' '~' ' '~' ~t~ ' ~ ....
TOg~L LENGTH
TILE DRAIN FIELD:
-4
DISTANCE FROM WELL ///O-~? FOUNDATION
NUMBER OF LINES
DISTANCE BETWEEN LINES
NEAREST LOT LINE_ OF LINES
TRENCH WIDTH__~ /'IN. TOTAL EFFECTIVE
ABSORPTION AREA SQ. FT. LENGTH OF EACH LINE
~7, ~'~,.~ DEPTH OF FILTER
DEPTH: TOP OF TILE TO FINISH GRADE '~, '?~ATERIAL BENEATH TILE
ABOVE T'LE
.IN.
WELL:~'~ 't,';'/:' "~ ~ ~
BUILDING NEAREST NEAREST SEPTIC SEEPAGE
FOUNDATION__ LOT LINE_ SEWER LINE __ TANK__ SYSTEM
CESSPOOL OTHER SOURCES
APPROVED __ DISAPPROVED REMARKS
DISTANCE FROM:
DISTANCES:
SEWER LINE DEPTH:
PIPE MATERIAL:
LOT SLOPE:
REMARKS:
DIAGRAM OF SYSTEM
DATE
G.A.A.B.
Form EQ-O32
Grea :R ANCHORAGe Area BOR Jgh
DEPARTMENT OF ENVIRONMENTAL QUALITY
3330 "C" STREET ANCHORAGE, ALASKA 99503
TELEPHONE 274-4561
SEWAGE DISPOSAL SYSTEM m APPLICATION AND PERMIT
PERMIT NO..
INSTALLATION OF: SEPTIC TANK SEEPAGE PIT
TYPE AND SIZE OF FACILITY TO BE SERVED
FINANCED THROUGH
SOIL TEST RESULTS
TO BE INSTALLED BY
NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST
COMPLETION DATE ANTICIPATED
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
, ~ SEEPAGE AREA SIZE TYPE ~~~
MINIMUM DISTANCES, REQUIREMENTS
DIAGRAM OF SYSTEM
FOUNDATION TO SEPTIC TANK
FOUNDATION TO SEEPAGE PIT
SEPTIC TANK TO SEEPAGE PIt WALL
SEPTIC TANK . , SEEPAGE Pit
TO NEAREST LOT Line.
WELL TO SEPTIC TANK
DRAIN FIELD
WATER MAIN TO SEPTIC TANK
DRAIN FIELD
SEPTIC TANK, , SEEPAGE PIT
TO RIVER, LAKe, STREAM.
DRAIN FIELD
DRAIN FIELD
SEEPAGE PIT
ALSO CONSIDER AREA WELLS.
SEEPAGE PIT
DRAIN FIELD
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT
FITTED WITH Ai RTIGHT REMOVABLE CAPS.
GRAVEL BACKFILL
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION.
o~
LICENSED DESIGNER
I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-6B AND THAT THe ABOVE
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAiD
DATE - _ APPLICANT'S SIGNATU
FORM NO. EQ-01 6
GREATEr ANCHORAGE AREA Borough
DEPARTMENT OF ENVIRONMENTAL (~UALITY
:3330 "C" STREET ANCHORAGE, ALASKA 99503
TELEPHONE 274-4561
NAME OF APPLICANT
INSTALLATION LOCATION
LEGAL DESCRIPTION
,.STALLAT,ONOP: SEPTIOTANK
TYPE AND SIZE OF FACILITY TO BE SERVED
FINANCED THROUGH
SOIL TEST RESULTS
COMPLETION DATE ANTICIPATED
PERMIT NO.
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT
SEEPAGE PIT DRAIN FIELD OTHER
NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
SEPTIC TANK SIZE TYPE SEEPAGE AREA SIZE TYPE
MINIMUM DISTANCES, REQUIREMENTS
DIAGRAM OF SYSTEM
FOUNDATION TO SEPTIC TANK
FOUNDATION TO SEEPAGE PIT
DRAIN FIELD
SEPTIC TANK TO SEEPAGE PIT WALL
S, EPTI C TANK
TO NEAREST LOT LINE.
., SEEPAGE PIT
· DRAIN FIELD
WELL TO SEPTIC TANK
DRAIN FIELD
SEEPAGE PIT
ALSO CONSIDER AREA WELLS.
WATER MAIN TO SEPTIC TANK
DRAIN FIELD
SEEPAGE PIT
SEPTIC TANK, ., SEEPAGE PIT
TO RIVER, LAKE, STREAM.
, DRAIN FIELD
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT
FITTED WITH AIRTIGHT REMOVABLE CAPS.
GRAVEL BACKFILL
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION.
OR
LICENSED DESIGNER
I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 25-68 AND THAT THE ABOVE
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE.
FORM NO. E:Q-OI G
3J3() "I" SLrcuL
//
- /\nchora~le, Al,~ska 995(;3
.' 2t)11,2 I,()(; - I'E](()I,A'I'If)N
Performed for Ir':.r.,t~ ,?:~-,.,].~ '
Legal I)esc . :--. ............... ~ ..................... Date Perfor,ed
This form reports: Soils log ': .... ]-'~--];e~%i~Z'i6~-~i:~%- ........
Was ground water encountered?_ v~,~._ =~ ........ If yes, at what depl'.h?. ....
;',:rforlllC'd I;3 . . (,ertl Fl.:,l U _.h,,Le: ..J.,.?. :_4.,..~f'7~
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www. muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I,D. 051-141-02
GENERAL INFORMATION
Complete legal description
Location (site address)
Lot 47, Delucia Subdivision
22792 Needels Loop Chugiak, AK 99567
ExPiration Date: Z~/)~
Current Property owner(s) Charles F. Stiehr
Mailing address 22792 Needels Loop Chugiak, AK 99567
Day phone 301-6243
Lending agency
Day phone
Mailing address
..
Real Estate Agent
Day phone
~ MaJ!i/3g:Addre.s,s,
Ut/f/ess otherwtse req, QeS~t~d, COSA will be held by DSD for pickup.
Three (3)
NUMBER OF BEDR0'?,Ms:
:TYPE'¢OF WATER SUPPEY:
Ifidividual'W~ll , "
I'~dMdual ,waterstorage
Public Water System
TYPE OF WASTEWATER DISPOSAL:
Individual On-site []
Individual Holding Tank []
Community On-site []
Public Sewer []
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineeCs work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I vedfy that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Anderson Engineering
Address P.O. Box 240773 Anchorage, AK 99524
Engineer's Printed Name Michael E. Anderson, P.E.
DSD SIGNATURE
Approved for _~
Disapproved.
Conditional approval for
bedrooms.
Phone 522-7773
Date 11/30/201.1 , .
. A
bedrooms, with the following stipulations:
Attachments: COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitr~te Advisory
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
Original Certificate Date: f~/~ / J I
(Rev. 11/05)
MuniciPality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www. muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description:
A. WELL DATA
Well type Pdvate
Date completed 12/75'
Total depth 226.7 ft.
Lot 47, Delucia Subdivision
Parcel ID: 051-141-02
IfA, B, or C provide PWSID # Well Log (Y/N)
SanitarY seal (Y/N) Y Wires properly protected (Y/N)
Cased to 226.7 ft. Casing height (above ground)
FROM WELL LOG AT INSPECTION
Date of test 12/75 9/28/11
Static water level Unknown ft. 166.2 ft.
Well production 20 g.p.m. 3.3 g.p.m.
WATER SAMPLE RESULTS:
Coliform 0 colonies/100mL Nitrate 5.77 mg/L
ArseniC: N/D mg/I Date of sample: 9/28/11
SEPTIC/HQ~DING TANK DATA
Tank Type/Material Septic/Sunset Plastic
Tank size 1,000 gal. ' Number of Compartments Two
F'oundation cleanout (Y/N) Y'
Date~of pumping 9/22/2011 -,
ABSORPTION FIELD DATA
Date installed 11/21/2011
Length 44 ft.
Total depth 8.5-9.3 ft.
Depression over tank.(Y/N)
Pumper JRs Pumping
Collected by: F. Kenley
Date installed 6/14/76
Cleanouts (Y/N) Y
N High water alarm (Y/N) N
Soil rating (g.p.d./~ or ft2/bdrm) 1.2 GPD/SF
Width 5 ft.
Eft. absorption area 455 ft2 Monitoring tube
Date of adequacy test New const. Results (Pass/Fail)
Fluid depth in absorption field before test in. Water added~
Elapsed Time: ~ min. Final fluid depth
Any rejuvenation treatment (past 12 mo.) (YIN & type)
System type 5' Wide Trench
Gravel below pipe 3-4 ft.
Y Depression over field N
For bedrooms
gal. New depth in.
in. Absorption rate >= g.p.d.
If yes, give date
Y
>1'8 in.
D. LIFT STATION
Date installed
"Pump on" level at ~ in.
Datum
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot 86'
Absorption field on lot >100'
Public sewer main N/A
Sewer/septic service line >25'
Animal containment areas >50'
Size in gallons
"Pump off" level at
Cycles tested
in.
Manhole/Access (Y/N)
High water alarm level at
Meets alarm & circuit requirements?
in.
On adjacent lots >1oo'
On adjacent lots >1oo'
Public sewer manhole/cleanout
Holding tank N/A
Manure/animal excrete storage areas
N/A
> 100'
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >5' Property line >5'
Water main N/A Water service line >10'
Wells on adjacent lots >lOO'
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line >10' Building foundation >1o'
Water Service line >1o' Surface water >1oo'
Curtain drain None Noted Wells on adjacent lots >1oo'
Absorption field >5'
Surface water >1oo'
Water main >1o'
Driveway, parking/vehicle storage
F. COMMENTS: Absorption Trench Reconstructed. Existing Septic Tank Suitable for Continued Use.
>5'
G. ENGINEER'S CERTIFICATION
review of Municipal taco.s that the above systems am in
cos i, o,
Enginee~ s Printed Name Michael E. ~derson, v.~.
Date ~ 1/30/2011
COSA Fee $.
Date of Payment
Receipt Number
(Rev. 11/05)
Waiver Fee $
Date of Payment
Receipt Number
Municipality of Anchorage
Community Development Department
Development Services Division
On-Site Water and Wastewater Program
4700 Elmore Street
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
Nitrate Advisory
Certificate of On-Site Systems Approval' # OSC111462
A Certificate of On-Site Systems Approval inspection and test of potable
water was recently conducted on the well water supply on Lot 47 of Delucia
subdivision. This inspection revealed a nitrate concentration of 5.77
milligrams per liter (mg/L) was reported for the property's well water
sample. The Environmental Protection Agency (EPA) has established a
maximum contaminant level (MCL) of 10.0 mg/L for public drinking water
systems. While private wells are not subject to this regulation, EPA
standards are based on existing health information and can therefore be used
to gauge the relative quality of water from private wells. Please see the
attached "Nitrate Fact Sheet" for important information regarding nitrate.
This advisory must be attached to all copies of the subject Certificate of On-
Site Systems Approval.
i
R~180.00'
PLOT PLAN AS BUILT X SCALE 1' = 40' GRID NW 1259 Project No. 11-181/A3
La n g (:907) 522-6476
Registered Land Surveyors (:907) 522-4625
kglanglsOalaska.nst / JclanglsOalaska.nef
& Associates, inc. 1~500 Daryl Avenue, Anchorage, Alaska 99515-;5049
Phone
Fax
I hereby certify that I have surveyed the following described properly:
LOT 47, DELUCIA SUBDIVISION, (PLAT P-684)
Anchorage Recording District, Alaska, and that the Improvements slfuatsd thereon are
within the properly lines and do not encroach onto the properly adjacent fhersto, that
no Improvements on the properly lying adjacent thereto encroach on the surveyed
premises and that there are no roadways, transmission lines or other vlslble
easements on said property except as Indicated hereon.
Dated this the ~.~p~ur~ Day of f~o~/~,~- , ~1t , at Anchorage, Alaska
It is the responsibility of the owner fo determine the existence of any easements,
covenants, or restrictions which do not appear on the recorded subdivision plat.
ROBERTA. SHAFER
CIVIL ENGINEER
694-2979
October 31, 1983
ADEQUACY TEST
WATER AND SEWER INSPECTION
WELL INSPECTIONS AND
FLOW TEST
SITE PLANS
ROAD DFSIGN
SOIL TEST
ON SITE WASTE WATER
DISPOSAL SYSTEM DESIGN
EXCAVATION WORK
-RECEIVED
Luzette Steihr
'bdivision
REFERENCE: Lot ~ ~
A sewer system adequacy test was performed on the system located
on the referenced property, as you-requested. The septic tank
was pumped and verified to have a capacity of approximately
'1000 gallons. The seepage pit was charged with 1000 gallons
.of fresh water and after a period of 24 hours all the water
which had been added to the crib had percolated out.
It can be concluded from this test that the waste water disposal
system intended to serve a three bedroom residence located on
~tSis property is currently functioning adequately. However,
the system cannot be guaranteed against subsequent failure.
If we may be of further service, please do not he~itate to
call.
Sin~r~e y. .. ~/
cc: Municipality of Anchorage
Department of Health and Environmental Protection
SRB 196X EAGLE RIVER. ALASKA 99577
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES
........ , ......
MUNICIPALITY OF ANCHORAGE-- DEPT. OF t~ALTH &
DEPARTMENT OF HEALTH ~ ENVIRONMENTAL PROT~NMENTAL~:~7~CTION 825 L Street - Anchorage, Alaska 99501
JAN 1 1 1979
DIvISIoN
ENVIRONMENTAL
ENGINEERING
Telephone 264-4720 RECEIVED
DIRECTIONS: Complele all parts-on page 1. Incomplete requests will nol be processed. Please allow ten {10) days for processing.
PHONE
PHONE
1, PROPERTY.OWNER
MAI LI~IG ADDHESS
PROPERTY RESIDENT (If'"~ifferent from above)
PHONE
PHONE
2. BUYER
MAI LING ADDRESS
3. LENDING INSTITUTION
MAILING ADDRESS
4. REALTOR/AGENT I PHONE
?.//,r.~,~, .(
MAI LInG ADDR
15.' LEGAL DESCRIPTION
STREET LOCAT~d'N
6. TYPE OF RESIDENCE
NUMBER OF BEDROOMS
~ SINGLE FAMILY [] One [] Four
[] Two [] Five
[] MULTIPLE FAMILY '~' Three [] Six
F-]' Other
7. WATER SUPPLY
~ INDIVIDUAL ATTACH WELL LOG. A well log ~s required for all wells drilled
I-~ COMMUNITY since June 1975, For wells drilled prior to that date, give well
[] PUBLIC UTILITY depth (attach Icg if available.)
8. SEWAGE DISPOSAL SYSTEM .
~ INDIVIDUAL/ON-SITE** If ,nd,mdual/o,~ s,te. g,ve ,nstallatmn date /~?~
~ PUBLIC UTILITY If system is over two (2) years old an adequacy test is r~uired
~ bAthis Departmeng
72-010(3/78)
("~,-~-n~}.o~ back o~-de~. 0v~4-il ~e_ Cav~ ob'haiv~ US~ a
GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
3330 "C" Street, Anchorage, Alaska 99503 274-4561
m Date Received
Approval requested by:~]':}'''
Mailin§ Address: P.O. Box 4-2Q~Q
June 18 ,m 1976'~.::,.%,~
,.Time of Inspection
Date of Inspection
"~ Property Owner:
· ~'~..
,,~,, Mailing Address:
: '!74.
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
FOR
First National Bank of Anchorage
~Phone: 274-1521
Jerry and Janet Fenton
P.O. Box 279, Chugiak, Alaska 99567
Legal Description:' Lot 47, Delucia Subdivision
Location::~ Mile 20, Old Glenn Highway
Type of facility to be inspected Single Family
6. Well Data:
Phone:
No,. of bedrooms--'
B. Depth 225'
D.: Bacterial Ana]ys.is Satisfactory
A. Type Individual
C. Construction
7 Sewage Disposal ,stem: .... ,~., · ~'.~: ..... ~ '~
~.~'.~. A. Installed ~J: er, "~" ..... '
--~;~' C, Septic Tank:-- l, Size 2, Manufacturer
.?:%~ D, Seepage Pit: .1, Absorption Area ~ 2, Material
, ~. ~ E.. a~sposal F~e]d:,-lotal length :of.~
?8, Distances:. ' . . .~. '" ·
' ::J:~, '~
{~{., ~,A,. Well..to: ?;:Septic tank ,:~}Absorption area /0~ ~ ~Sewer..Lines.'
.... · ..~:~ .. Nearest lot l~ne , Other contamination
· ,;~?~' B. Foundag~on go sepg~c tank Absorption area
~ ?,~.. C. ~bsorpg~on area ~o nearest lot
:; .2,'~?',, -
Page 1 of~,~two
. ~.Page 2 of~two pages - Re--,st for Approval of Individual
Lot 47, Delu¢ia Subdivision
'er & Water Facilities
Date
Approval .Valid for one year from date signed
Greater'..Ancho~age Area Borough,, Department of Environmental
· : .. ~, ,~. ......... ,.,~ ~', ,.~', ~. ¥.:,~ .... DIAGRAM OF SYSTEM,'~-':;]::-~
6-18Z76
I certify that the information contained in this request for approval~jto be.a true and
accurate~representation of the subject sewer and.water facilities and)these'.,facilities
are operating satisfactorily. . ' m''~''''''
SIGNED
EQ-.034 (1/74)
Date
GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
3330 "C" St., Anchorage, Alaska 99503 - 274-4561
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
1. Type of Inspection: CMRO VA ~/1/F(~ FHA CONV
2. Property Owner: /(L,~ ~' ~.Tt~ ~- ! 7-'o AJ
5. Name of Realtor or Agent: ~~ ~/u~
Mailing Address: ~ ~ ~ax ~'7~ Phone
6. Legal Description:
7. Type of Faci 1 i ty to be inspected:
8. Water Supply ~' '~)
Type of Supply: Public Utility Individual
If Individual, number of dwellings presently served
If Individual, depth of well ~5 ~~ .'JO-~
Sewage Disposal System
Type of System: Public Utility Individual (on-site)
If Individual, date of installation
EQ-03?
(]/74)
GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
"C" Street, Anchorage, Alaska 99503 274-4561
Date Received
Time of Inspection
Date of Inspection[~r_~Z.~q,
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER&WATER FACILITIES
FOR
4.
5.
6.
1. Approval requested
Mailing Address: ~
2. Property Owner: ~_~,
Mailing Address: ~r~
Legal Description:
Location:
Type of facility to be inspected
Well Data:
A. Type
C. Construction
7. Sewage Disposal System:
A. Installed
B. Depth ~FAr~'
D. Bacterial Analysis -~'~T/~
B. Installer
C. Septic Tank: 1. Size
2. Manufacturer
D. Seepage Pit: 1. Absorption Area
2. Material
E. Disposal Field: Total length of lines
8. Distances:
A. Well to: Septic tank
, Absorption area
, Sewer Lines
Nearest lot line
Other contamination
B. Foundation to septic tank
, Absorption area
C. Absorption area to nearest lot line
EQ-034 (1/74) Page I of two pages
~age 2 of two pages - Re
st for Approval of Individual
er & Water Facilities
Legal Description
Comments
Approved ~/d~ Disapproved
Date
ApprovalValid for one year from date signed
Greater~Anchorage Area Borough, Department of Environmental Quality
DIAGRAM OF SYSTEM
certify that the information contained in this request for approval to be a true and
accurate representation of the subject sewer and water facilities and these facilities
are operating satisfactorily.
SIGNED Date
EQ-034 (1/74)
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
2510 East Tudor Road, Anchorage, Alaska 99504 276-2221
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER and WATER FACILITIES
1. Type of Inspection:
2. Property Owner:
Mailing Address:
3. Name of Buyer:
_CONV
Day Phone:
Mailing Address: ~ ~e,~ ?~./ ~----~,(a.~' Day Phone:
4. Name of Lending Institution: /~ ~eZ'/ ~ ~ ~
Mailing Address: ~ ~ ~ ~ ~ ~7 Phone:
5. Name of Realtor or Agent: ~¢~.~ ~w* ~
Mailing Address: ~ ~ ~ Phone:
~. ~e,., ~escr,.tion: '~'~ ~7 ~ ~ Z ~'/~
Type of Facility to be Inspected: ~ ~ ~ tJ~ 5,'" ~ .~' No. Bdrms. ~
Water Supply
Type of Supply: Public Utility
If Individual, number of dwellings presently served
If Individual, depth of well '~ ~'//
Sewage Disposal System
Type of System: Public Utility
,Individual
Individual (on-site)
If Individual, date of installation
72-003( 3/76)
MUNICIPALITY OF ANCHORAGE
POUCH 6-650 ANCHORAGE, ALASKA 99502
December 10, 1975
First National Bank of Anchorage
Post Office Box 4-2090
Anchorage, Alaska 99509
SUBJECT: Lot 47 Delucia Subdivision
Dear Sirs:
An on-site inspection was made on the above subject property. The sewage disposal
system does not comply with minimum requirements set forth in our ordinance.
The sewage disposal system will have to be upgraded to comply with current ordinances.
This department will grant a temporary approval based upon escrow funds set aside
to install a new sewage disposal system by June 1, 1976.
Until such time that a new sewage disposal system can be installed this department
has no objections of the continued use of this system.
If you have any questions regarding this matter please call me at 694-2161.
Sincerely,
Fred Beatty
Sanitarian
FB/sg