Loading...
HomeMy WebLinkAboutDELUCIA LT 47b lucia Lot 47 051 - 141 Municipality of Anchorage Development Department Building Safety Division On-Site Water and Wastewater Program, 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: 0SPl11321 PID Number: 051-141-02 Name: Charles F. Stiehr Wastewater System: [] New [] Upgrade Address: P.O. BOX 671108 Chugiak, AK 99567 ABSORPTION FIELD Phone: Number of Bedrooms: 3 [] Deep Trench J~ Shallow Trench [] Bed [] Mound [] Other: Soil Rating: Total Depth from odginal grade: LEGAL DESCRIPTION 1.2 CpD/Pt2 8.5-9.3 Ft. Block: Lot: 47 Subdivision: Depth to pipe bottom from odginal grade: Gravel depth beneath pipe: Delucia 4.5-6.0 Ft. 3-4 Ft. Township: Range: Section: Fill added above odginal grade: Gravel Length: 0 Ft. 44 Ft. Well: [] New [] Upgrade Gr~ve, w~dth: Uumberoflines: Distance between lines: 5 Ft. 1 Ft. Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: Existing Ft. Ft. 455 Ft2 ASTM D3034 PVC Driller: Date Ddlled: Static Water Level: Installer: Date Installed: Ft. Scott's Services 11/21-22/2011 Yield: GPM Pump Set at: Ft. Casing Height Above Ground:Ft' TAN K SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other: T~ To Septic Absorption Lift Holding ~ublic/Private Manufacturer: Capacity: From~ Tank Field Station Tank Sewer Line Existing Gal. Material: Number of Compar[ments; We, 86' >100' N/A N/A >25' sur~acewater >100' >100' N/A N/A ~ / LIFT STATION Size: Manufacturer: Lot Line >5' > 10' N/A N/A Gal. "Pump on" level at: "Pump off" level at: in. High water alarm at: Foundation >5' >10' N/A N/A in. in. Pump Make & Model Electrical Inspections performed by: Curtain Drain None Noted Remarks: Existing Septic Tank Verified Sound for Continued Use. BENCH MARK Location and Description: Northwest 16' of Absorption Trench is 4' Effective Depth. Garage Slab. Assumed Elevation: 8" Insulation Over Distribution Line Under Driveway. 100.0 Ft. Inspections performed by: A. Harala Dates: 1st 8/28/2007 Development Services Department Approval Conditional Approval Date: Reviewed and approved b /1~.,"~. Date: /,:~ I / ,./ O.C. 7 I N I,I Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP111321 Page 3 of 3 PID NO.: 051-141-02 /¢/'~==~ Existing / / 11,ooo Ga,on // ' SepticTank I EXISTING SEPTIC TANK Tank Verified Suitable for Continued Use. 99.4 Finished Grade Existing Grade ~90.1 81.6 No Groundwater 98.6 Geotextile Fabric Finished Grade Existing Grade 97.9 Drainfield Rock 93.4 44' (Trench Length) NOTE: Northwest 16' of Trench Has 4' Effective Depth. Remainder of Trench Nominal 3' Effective Depth. PROFILE AS-BUILT On-Site Wastewater Disposal System Permit OSPl11321 05114102000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: Tax Code Number: Work Type: Upgrade Permit Effective Dates: November 04, 2011 to Design Engineer: ANDERSON ENGINEERING Subdivision: DELUCIA November 03, 2012 Site LegalAddress: DELUCIA LT 47 G:1259 Owner/Address: STIEHR CHARLES F AKA STIEHR CHUCK PO BOX 671108 CHUGIAK AK 995671108 Site Mailing Address: 22792 NEEDELS LOOP, Chugiak Lot Size in Sq Ft: 53579 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field N SepticTank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: Verify and document that the existing drainfield is constructed in accordance with the current version of the wastewater code. Submit results with the final inspection report. Date: Date: MUN ICIPALITY OF ANCHORAGE Community Development Department Development Services Division On-Site Water & Wastewater Program Mayor Dan Sullivan ON-SITE SEWERNVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 051-141-02 Property owner(s): Charles F. Stiehr Day phone: 301-6243 Mailing address: P.O. Box 671108 Chugiak, AK 99567 Site address: 22792 Needels Loop Chugiak, AK 99567 Legal description (Sub'd., Block & Lot): Delucia Subdivision, Lot 47 Legal description (Township, Range & Section): Lot Size: 53,579 Sq. Ft. Number of Bedrooms: Three Phone: 90%343-7904 Fax: 907-343-7997 THIS APPLICATION IS FOR: ([~ all that apply) Absorption Field X Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] THIS APPLICATION IS AN: Initial [] Upgrade X Renewal [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: .'~ '2~O "'- Date of Payment: ~ I '- t - ~ Receipt Number: ~-,~2j\ ~ Permit No. C~.~'¢ \/\ ~'~ / Waiver Fees: Date of Payment: Receipt Number: Waiver No. C:\Users~AndEng\Desktop\Mike\T15N Lindberg\Permit Application.docC:\Users~AndEng\Desktop\Mike\T15N Lindberg\Permit Application.doc AN D ERS ON ENGI N EERI N G P.O. BOX 240773 · ANCHO~GE, AK 99524 522-7773 677-7766 (FAX) November 1,2011 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 Elmore Road Anchorage, AK 99519-6650 Subject: Lot 47, Delucia Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The existing septic system on the subject lot has failed and was recently upgraded without a permit. The trench does not meet the minimum requirements for a three- bedroom home and has been redesigned to meet Municipal Code as shown on the attached Site Plan. We are therefore requesting a permit be issued for the upgrade of the septic system to accommodate the three-bedroom home on the lot. The attached Site Plan and backup documentation identify the location and configuration of the existing and proposed septic system. The existing Septic Tank was recently verified sound for continued use. A statement to that effect will be provided with the inspection report for the new system. The existing absorption pit was completely abandoned in accordance with Municipal Code. Also identified on the plans are the locations of the existing well on this and adjacent lots and adjacent septic systems. No conflicts exist between the proposed septic system and the wells on this or adjacent lots. Protective radii are shown to the adjacent wells. Drainage arrows are shown indicating the current drainage patterns. The drainage patterns will be maintained after construction. The test hole placed on the lot indicated Well Graded Gravel with sand (GW/GM) the entire depth. The percolation rate was determined to be less than 5 minutes per inch. We have designed the new trench with an application rate of 1.2 gallons per date per square foot. We are proposing to place an 11' extension on the existing 33' long trench by 5' wide with a 3' effective depth. The actual dimensions of the existing trench will be verified at the time of construction. The total depth of the system will be 8' with the distribution line at 5' below the existing surface. The ground surface on the lot slopes slightly to the east in the area of the absorption Lot 47, Delucia Subdivision November 1, 2011 Page Two trench. The trench will be placed parallel to the contours of the ground as much as possible and in conformance with design criteria. A minimum of 100' will be maintained between all components of the septic system and the proposed well and from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments Z Z 7 ~007 LOT47, DELUCIA SUBDIVISION DESIGN FACTORS: Three Bedroom Home Perc. Rate: 1-5 Min./Inch Application Rate: 1.2 GPD/SF 3 Bedrooms * 150 GPD/Bedroom = 450 GPD SYSTEM REQUIREMENTS: 5' Wide Trench System Existing 1,000 Gallon Septic Tank 3' Drainfield Rock 450 GPD/1.2 GPD/SF/5 SF (Width) *.58 (Red. Factor)= 43.5 LF Trench Length THEREFORE: Construct a 44' Long x 5' Wide x 3' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 5' Below Original Ground Surface. Total Depth to be 8' Below Existing Ground. Provide 3' CoVer Over Absorption Trench and 4' Cover Over Septic Tank. ~Geotextile Fabric ~ 4" Perforated PVC (Holes Down) ~ Drainfield Rock Coarse Sand (See Specification) TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away g~ Minimum 6~ Separation From Bedrock. ' ~....~....~.~.. ~..~ .... Minimum 4 Separation From Groundwater. ~ ~..~,-~-~;~,..~ M' ' ' ' · ""'~"~'["~'~ ............. ,ri,mum 100 Separat,on From Pr,vate Wells ,n the Area. ~ "'C~A~.A.D~S~~ Mimmum 100 Separation From Su~ace Water or Streams. ~.~% No. cs-~3~ A700 DEPTH 1 2 3 4 5 6 7 8 9 11 20 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT /-.7, DELUCIA SUBDIVISION PERFORMED FOR: CHUCK STI~HR DATE: 10/2&/2011 PROJECT No.: PARCEL ID#: TECHNICIAN: TEST HOLE A I 0B/0G WELL GRADED GRAVEL WITH SAND GW/Gld WAS GROUND WATER ENCOUNTERED? __ IF YES ~ WHAT DEPTH? DEPTH OF WATER AFTER MONITORING: DATE OF MONITORING: B0H @ 17' M. ANDERSON OF ,4/;'.% ~;~ V~. ................ ~ ~ 49~b ~ ~ ~ Professional Engineen S~mp: SLOPE NO 11/5/2011 ~ E SITE PLAN SEE SITE PLAN DEPTH TO DATE READING GROSS Tilde NET TildE WATER NET DROP (MINUTES) (MINUTES) (INCHES) (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 10/24 1 2:08/2:18 10 1.25"/3.50" 2.25" 2 2:19/2:29 10 1.38"/3.50" 2.12" 3 2:30/2:40 10 1.25"/3.38" 2.13" 4 2:41/2:51 10 1.25"/3.38" 2.13" 5 2:52/3:02 10 1.13"/3.25" 2.12" 6 3:03/3:13 10 1.25"/3.38" 2.13" PERCOLATION RATE: 4.7 (MIN/INCH) PERC. HOLE DIA. 6" .(INCHES) TEST RUN BETWEEN: 5.5 FT. and 6.5 .FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: II/1/2011 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: T15N, R1W, SECTION 18, LOT 190B GENERAL: The scope of this project includes the construction of a new absorption trench 44' long by 5' wide by 3' effective depth at the location shown on the Site Plan. The total depth of the trench will be 8' below existing ground and the distribution pipe will be placed at 5.0' below the surface. Approximately 33' of the absorption trench is already in place and must be verified to be to the dimensions described above. The absorption trench must be constructed a minimum of 100' from any wells in the area and 100' from any surface water on this or adjacent lots. A minimum of 3' of cover is required over the absorption trench. In lieu of cover 2" of direct bury insulation and 2' of cover may be placed. The delivery line from the existing septic tank must be verified to have at least 4" of insulation. The existing septic tank has been verified suitable for continued use. A statement from the contractor to this effect is required. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor is also responsible to assure the separation distance from wells and surface water in the area is maintained. The engineer will accept no responsibility for Contractor errors. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal Systems must be certified by the Municipal Development Services Department Building Safety Division On Site Water and Wastewater Program for system installations. Owners installing their own systems must receive prior approval from the On Site Water and Wastewater Program before beginning system installation. Lot 47, Delucia Subdivision November 1, 2011 Page 2 of 4 SEPTIC TANK INSTALLATION - EXISTING 1. A new l i'000-gallon septic tank must be procured from a certified manufacturer if the tank found on site is not acceptable for continued use. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct -burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below the distribution pipe must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class Lot 47, Delucia Subdivision November 1, 2011 Page 3 of 4 "C" Well or 200' from any community well. The Contractor is solely responsible to assure these separation distances are met. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide' trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections must be completed during the construction of the septic system. These. inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not Lot 47, Delucia Subdivision November 1,2011 Page 4 of 4 be backfilled. The Contractor must notify the engineer 4 hours prior to the inspection to prevent delays. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. His measurements must include verification that the proper separation distances have been met. A certified surveyed as-built may also be required to assure the proper separation distances are met from wells in the area. The as-built will also include separation distances from streams or surface water in the area. GRE,..ER ANCHORAGE AREA BOR JGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL. SYSTEM . / ..... MAILING ADDRESS ~)' '(" ' '~:~'' ~ ~'':' / ';~' ,7'~ ' PHONE ~'C~" LOCATION ' .,~ '~ - LEGAL DESCRIPTION ~ ~'.-~ W./ ~L~-~t,.~ SEPTIC TANK: / NUMBER OF DISTANCE FROM WELL ~ ~' MANUFACTu R E R ¥''/~'~ f'~ MATERIAL COMPARTMENTS CAPACITY/~d-~ INSIDE LENGTH ~ INSIDE WIDTH LIQUID DEPTH LIQUID GALLON~. ~' '~' ' '~' ~t~ ' ~ .... TOg~L LENGTH TILE DRAIN FIELD: -4 DISTANCE FROM WELL ///O-~? FOUNDATION NUMBER OF LINES DISTANCE BETWEEN LINES NEAREST LOT LINE_ OF LINES TRENCH WIDTH__~ /'IN. TOTAL EFFECTIVE ABSORPTION AREA SQ. FT. LENGTH OF EACH LINE ~7, ~'~,.~ DEPTH OF FILTER DEPTH: TOP OF TILE TO FINISH GRADE '~, '?~ATERIAL BENEATH TILE ABOVE T'LE .IN. WELL:~'~ 't,';'/:' "~ ~ ~ BUILDING NEAREST NEAREST SEPTIC SEEPAGE FOUNDATION__ LOT LINE_ SEWER LINE __ TANK__ SYSTEM CESSPOOL OTHER SOURCES APPROVED __ DISAPPROVED REMARKS DISTANCE FROM: DISTANCES: SEWER LINE DEPTH: PIPE MATERIAL: LOT SLOPE: REMARKS: DIAGRAM OF SYSTEM DATE G.A.A.B. Form EQ-O32 Grea :R ANCHORAGe Area BOR Jgh DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 SEWAGE DISPOSAL SYSTEM m APPLICATION AND PERMIT PERMIT NO.. INSTALLATION OF: SEPTIC TANK SEEPAGE PIT TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH SOIL TEST RESULTS TO BE INSTALLED BY NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. , ~ SEEPAGE AREA SIZE TYPE ~~~ MINIMUM DISTANCES, REQUIREMENTS DIAGRAM OF SYSTEM FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT SEPTIC TANK TO SEEPAGE PIt WALL SEPTIC TANK . , SEEPAGE Pit TO NEAREST LOT Line. WELL TO SEPTIC TANK DRAIN FIELD WATER MAIN TO SEPTIC TANK DRAIN FIELD SEPTIC TANK, , SEEPAGE PIT TO RIVER, LAKe, STREAM. DRAIN FIELD DRAIN FIELD SEEPAGE PIT ALSO CONSIDER AREA WELLS. SEEPAGE PIT DRAIN FIELD CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH Ai RTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. o~ LICENSED DESIGNER I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-6B AND THAT THe ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAiD DATE - _ APPLICANT'S SIGNATU FORM NO. EQ-01 6 GREATEr ANCHORAGE AREA Borough DEPARTMENT OF ENVIRONMENTAL (~UALITY :3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 NAME OF APPLICANT INSTALLATION LOCATION LEGAL DESCRIPTION ,.STALLAT,ONOP: SEPTIOTANK TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH SOIL TEST RESULTS COMPLETION DATE ANTICIPATED PERMIT NO. SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT SEEPAGE PIT DRAIN FIELD OTHER NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE TYPE SEEPAGE AREA SIZE TYPE MINIMUM DISTANCES, REQUIREMENTS DIAGRAM OF SYSTEM FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL S, EPTI C TANK TO NEAREST LOT LINE. ., SEEPAGE PIT · DRAIN FIELD WELL TO SEPTIC TANK DRAIN FIELD SEEPAGE PIT ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK DRAIN FIELD SEEPAGE PIT SEPTIC TANK, ., SEEPAGE PIT TO RIVER, LAKE, STREAM. , DRAIN FIELD CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. OR LICENSED DESIGNER I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 25-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. FORM NO. E:Q-OI G 3J3() "I" SLrcuL // - /\nchora~le, Al,~ska 995(;3 .' 2t)11,2 I,()(; - I'E](()I,A'I'If)N Performed for Ir':.r.,t~ ,?:~-,.,].~ ' Legal I)esc . :--. ............... ~ ..................... Date Perfor,ed This form reports: Soils log ': .... ]-'~--];e~%i~Z'i6~-~i:~%- ........ Was ground water encountered?_ v~,~._ =~ ........ If yes, at what depl'.h?. .... ;',:rforlllC'd I;3 . . (,ertl Fl.:,l U _.h,,Le: ..J.,.?. :_4.,..~f'7~ Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I,D. 051-141-02 GENERAL INFORMATION Complete legal description Location (site address) Lot 47, Delucia Subdivision 22792 Needels Loop Chugiak, AK 99567 ExPiration Date: Z~/)~ Current Property owner(s) Charles F. Stiehr Mailing address 22792 Needels Loop Chugiak, AK 99567 Day phone 301-6243 Lending agency Day phone Mailing address .. Real Estate Agent Day phone ~ MaJ!i/3g:Addre.s,s, Ut/f/ess otherwtse req, QeS~t~d, COSA will be held by DSD for pickup. Three (3) NUMBER OF BEDR0'?,Ms: :TYPE'¢OF WATER SUPPEY: Ifidividual'W~ll , " I'~dMdual ,waterstorage Public Water System TYPE OF WASTEWATER DISPOSAL: Individual On-site [] Individual Holding Tank [] Community On-site [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineeCs work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I vedfy that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. DSD SIGNATURE Approved for _~ Disapproved. Conditional approval for bedrooms. Phone 522-7773 Date 11/30/201.1 , . . A bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitr~te Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: f~/~ / J I (Rev. 11/05) MuniciPality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: A. WELL DATA Well type Pdvate Date completed 12/75' Total depth 226.7 ft. Lot 47, Delucia Subdivision Parcel ID: 051-141-02 IfA, B, or C provide PWSID # Well Log (Y/N) SanitarY seal (Y/N) Y Wires properly protected (Y/N) Cased to 226.7 ft. Casing height (above ground) FROM WELL LOG AT INSPECTION Date of test 12/75 9/28/11 Static water level Unknown ft. 166.2 ft. Well production 20 g.p.m. 3.3 g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100mL Nitrate 5.77 mg/L ArseniC: N/D mg/I Date of sample: 9/28/11 SEPTIC/HQ~DING TANK DATA Tank Type/Material Septic/Sunset Plastic Tank size 1,000 gal. ' Number of Compartments Two F'oundation cleanout (Y/N) Y' Date~of pumping 9/22/2011 -, ABSORPTION FIELD DATA Date installed 11/21/2011 Length 44 ft. Total depth 8.5-9.3 ft. Depression over tank.(Y/N) Pumper JRs Pumping Collected by: F. Kenley Date installed 6/14/76 Cleanouts (Y/N) Y N High water alarm (Y/N) N Soil rating (g.p.d./~ or ft2/bdrm) 1.2 GPD/SF Width 5 ft. Eft. absorption area 455 ft2 Monitoring tube Date of adequacy test New const. Results (Pass/Fail) Fluid depth in absorption field before test in. Water added~ Elapsed Time: ~ min. Final fluid depth Any rejuvenation treatment (past 12 mo.) (YIN & type) System type 5' Wide Trench Gravel below pipe 3-4 ft. Y Depression over field N For bedrooms gal. New depth in. in. Absorption rate >= g.p.d. If yes, give date Y >1'8 in. D. LIFT STATION Date installed "Pump on" level at ~ in. Datum E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 86' Absorption field on lot >100' Public sewer main N/A Sewer/septic service line >25' Animal containment areas >50' Size in gallons "Pump off" level at Cycles tested in. Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? in. On adjacent lots >1oo' On adjacent lots >1oo' Public sewer manhole/cleanout Holding tank N/A Manure/animal excrete storage areas N/A > 100' SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >5' Water main N/A Water service line >10' Wells on adjacent lots >lOO' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >1o' Water Service line >1o' Surface water >1oo' Curtain drain None Noted Wells on adjacent lots >1oo' Absorption field >5' Surface water >1oo' Water main >1o' Driveway, parking/vehicle storage F. COMMENTS: Absorption Trench Reconstructed. Existing Septic Tank Suitable for Continued Use. >5' G. ENGINEER'S CERTIFICATION review of Municipal taco.s that the above systems am in cos i, o, Enginee~ s Printed Name Michael E. ~derson, v.~. Date ~ 1/30/2011 COSA Fee $. Date of Payment Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number Municipality of Anchorage Community Development Department Development Services Division On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 Nitrate Advisory Certificate of On-Site Systems Approval' # OSC111462 A Certificate of On-Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Lot 47 of Delucia subdivision. This inspection revealed a nitrate concentration of 5.77 milligrams per liter (mg/L) was reported for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On- Site Systems Approval. i R~180.00' PLOT PLAN AS BUILT X SCALE 1' = 40' GRID NW 1259 Project No. 11-181/A3 La n g (:907) 522-6476 Registered Land Surveyors (:907) 522-4625 kglanglsOalaska.nst / JclanglsOalaska.nef & Associates, inc. 1~500 Daryl Avenue, Anchorage, Alaska 99515-;5049 Phone Fax I hereby certify that I have surveyed the following described properly: LOT 47, DELUCIA SUBDIVISION, (PLAT P-684) Anchorage Recording District, Alaska, and that the Improvements slfuatsd thereon are within the properly lines and do not encroach onto the properly adjacent fhersto, that no Improvements on the properly lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other vlslble easements on said property except as Indicated hereon. Dated this the ~.~p~ur~ Day of f~o~/~,~- , ~1t , at Anchorage, Alaska It is the responsibility of the owner fo determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. ROBERTA. SHAFER CIVIL ENGINEER 694-2979 October 31, 1983 ADEQUACY TEST WATER AND SEWER INSPECTION WELL INSPECTIONS AND FLOW TEST SITE PLANS ROAD DFSIGN SOIL TEST ON SITE WASTE WATER DISPOSAL SYSTEM DESIGN EXCAVATION WORK -RECEIVED Luzette Steihr 'bdivision REFERENCE: Lot ~ ~ A sewer system adequacy test was performed on the system located on the referenced property, as you-requested. The septic tank was pumped and verified to have a capacity of approximately '1000 gallons. The seepage pit was charged with 1000 gallons .of fresh water and after a period of 24 hours all the water which had been added to the crib had percolated out. It can be concluded from this test that the waste water disposal system intended to serve a three bedroom residence located on ~tSis property is currently functioning adequately. However, the system cannot be guaranteed against subsequent failure. If we may be of further service, please do not he~itate to call. Sin~r~e y. .. ~/ cc: Municipality of Anchorage Department of Health and Environmental Protection SRB 196X EAGLE RIVER. ALASKA 99577 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES ........ , ...... MUNICIPALITY OF ANCHORAGE-- DEPT. OF t~ALTH & DEPARTMENT OF HEALTH ~ ENVIRONMENTAL PROT~NMENTAL~:~7~CTION 825 L Street - Anchorage, Alaska 99501 JAN 1 1 1979 DIvISIoN ENVIRONMENTAL ENGINEERING Telephone 264-4720 RECEIVED DIRECTIONS: Complele all parts-on page 1. Incomplete requests will nol be processed. Please allow ten {10) days for processing. PHONE PHONE 1, PROPERTY.OWNER MAI LI~IG ADDHESS PROPERTY RESIDENT (If'"~ifferent from above) PHONE PHONE 2. BUYER MAI LING ADDRESS 3. LENDING INSTITUTION MAILING ADDRESS 4. REALTOR/AGENT I PHONE ?.//,r.~,~, .( MAI LInG ADDR 15.' LEGAL DESCRIPTION STREET LOCAT~d'N 6. TYPE OF RESIDENCE NUMBER OF BEDROOMS ~ SINGLE FAMILY [] One [] Four [] Two [] Five [] MULTIPLE FAMILY '~' Three [] Six F-]' Other 7. WATER SUPPLY ~ INDIVIDUAL ATTACH WELL LOG. A well log ~s required for all wells drilled I-~ COMMUNITY since June 1975, For wells drilled prior to that date, give well [] PUBLIC UTILITY depth (attach Icg if available.) 8. SEWAGE DISPOSAL SYSTEM . ~ INDIVIDUAL/ON-SITE** If ,nd,mdual/o,~ s,te. g,ve ,nstallatmn date /~?~ ~ PUBLIC UTILITY If system is over two (2) years old an adequacy test is r~uired ~ bAthis Departmeng 72-010(3/78) ("~,-~-n~}.o~ back o~-de~. 0v~4-il ~e_ Cav~ ob'haiv~ US~ a GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 m Date Received Approval requested by:~]':}''' Mailin§ Address: P.O. Box 4-2Q~Q June 18 ,m 1976'~.::,.%,~ ,.Time of Inspection Date of Inspection "~ Property Owner: · ~'~.. ,,~,, Mailing Address: : '!74. REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR First National Bank of Anchorage ~Phone: 274-1521 Jerry and Janet Fenton P.O. Box 279, Chugiak, Alaska 99567 Legal Description:' Lot 47, Delucia Subdivision Location::~ Mile 20, Old Glenn Highway Type of facility to be inspected Single Family 6. Well Data: Phone: No,. of bedrooms--' B. Depth 225' D.: Bacterial Ana]ys.is Satisfactory A. Type Individual C. Construction 7 Sewage Disposal ,stem: .... ,~., · ~'.~: ..... ~ '~ ~.~'.~. A. Installed ~J: er, "~" ..... ' --~;~' C, Septic Tank:-- l, Size 2, Manufacturer .?:%~ D, Seepage Pit: .1, Absorption Area ~ 2, Material , ~. ~ E.. a~sposal F~e]d:,-lotal length :of.~ ?8, Distances:. ' . . .~. '" · ' ::J:~, '~ {~{., ~,A,. Well..to: ?;:Septic tank ,:~}Absorption area /0~ ~ ~Sewer..Lines.' .... · ..~:~ .. Nearest lot l~ne , Other contamination · ,;~?~' B. Foundag~on go sepg~c tank Absorption area ~ ?,~.. C. ~bsorpg~on area ~o nearest lot :; .2,'~?',, - Page 1 of~,~two . ~.Page 2 of~two pages - Re--,st for Approval of Individual Lot 47, Delu¢ia Subdivision 'er & Water Facilities Date Approval .Valid for one year from date signed Greater'..Ancho~age Area Borough,, Department of Environmental · : .. ~, ,~. ......... ,.,~ ~', ,.~', ~. ¥.:,~ .... DIAGRAM OF SYSTEM,'~-':;]::-~ 6-18Z76 I certify that the information contained in this request for approval~jto be.a true and accurate~representation of the subject sewer and.water facilities and)these'.,facilities are operating satisfactorily. . ' m''~'''''' SIGNED EQ-.034 (1/74) Date GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" St., Anchorage, Alaska 99503 - 274-4561 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES 1. Type of Inspection: CMRO VA ~/1/F(~ FHA CONV 2. Property Owner: /(L,~ ~' ~.Tt~ ~- ! 7-'o AJ 5. Name of Realtor or Agent: ~~ ~/u~ Mailing Address: ~ ~ ~ax ~'7~ Phone 6. Legal Description: 7. Type of Faci 1 i ty to be inspected: 8. Water Supply ~' '~) Type of Supply: Public Utility Individual If Individual, number of dwellings presently served If Individual, depth of well ~5 ~~ .'JO-~ Sewage Disposal System Type of System: Public Utility Individual (on-site) If Individual, date of installation EQ-03? (]/74) GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality "C" Street, Anchorage, Alaska 99503 274-4561 Date Received Time of Inspection Date of Inspection[~r_~Z.~q, REQUEST FOR APPROVAL OF INDIVIDUAL SEWER&WATER FACILITIES FOR 4. 5. 6. 1. Approval requested Mailing Address: ~ 2. Property Owner: ~_~, Mailing Address: ~r~ Legal Description: Location: Type of facility to be inspected Well Data: A. Type C. Construction 7. Sewage Disposal System: A. Installed B. Depth ~FAr~' D. Bacterial Analysis -~'~T/~ B. Installer C. Septic Tank: 1. Size 2. Manufacturer D. Seepage Pit: 1. Absorption Area 2. Material E. Disposal Field: Total length of lines 8. Distances: A. Well to: Septic tank , Absorption area , Sewer Lines Nearest lot line Other contamination B. Foundation to septic tank , Absorption area C. Absorption area to nearest lot line EQ-034 (1/74) Page I of two pages ~age 2 of two pages - Re st for Approval of Individual er & Water Facilities Legal Description Comments Approved ~/d~ Disapproved Date ApprovalValid for one year from date signed Greater~Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date EQ-034 (1/74) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 2510 East Tudor Road, Anchorage, Alaska 99504 276-2221 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER and WATER FACILITIES 1. Type of Inspection: 2. Property Owner: Mailing Address: 3. Name of Buyer: _CONV Day Phone: Mailing Address: ~ ~e,~ ?~./ ~----~,(a.~' Day Phone: 4. Name of Lending Institution: /~ ~eZ'/ ~ ~ ~ Mailing Address: ~ ~ ~ ~ ~ ~7 Phone: 5. Name of Realtor or Agent: ~¢~.~ ~w* ~ Mailing Address: ~ ~ ~ Phone: ~. ~e,., ~escr,.tion: '~'~ ~7 ~ ~ Z ~'/~ Type of Facility to be Inspected: ~ ~ ~ tJ~ 5,'" ~ .~' No. Bdrms. ~ Water Supply Type of Supply: Public Utility If Individual, number of dwellings presently served If Individual, depth of well '~ ~'// Sewage Disposal System Type of System: Public Utility ,Individual Individual (on-site) If Individual, date of installation 72-003( 3/76) MUNICIPALITY OF ANCHORAGE POUCH 6-650 ANCHORAGE, ALASKA 99502 December 10, 1975 First National Bank of Anchorage Post Office Box 4-2090 Anchorage, Alaska 99509 SUBJECT: Lot 47 Delucia Subdivision Dear Sirs: An on-site inspection was made on the above subject property. The sewage disposal system does not comply with minimum requirements set forth in our ordinance. The sewage disposal system will have to be upgraded to comply with current ordinances. This department will grant a temporary approval based upon escrow funds set aside to install a new sewage disposal system by June 1, 1976. Until such time that a new sewage disposal system can be installed this department has no objections of the continued use of this system. If you have any questions regarding this matter please call me at 694-2161. Sincerely, Fred Beatty Sanitarian FB/sg ','RA MI D PRI NTI.N G COMPANY 1413 G STREET ANCHORAGE, ALASKA 9950! PHONE 279-6323